Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Nucl Cardiol ; 30(3): 955-969, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-35851642

RESUMEN

BACKGROUND: We present an automatic method for coronary artery calcium (CAC) quantification and cardiovascular risk categorization in CT attenuation correction (CTAC) scans acquired at rest and stress during cardiac PET/CT. The method segments CAC according to visual assessment rather than the commonly used CT-number threshold. METHODS: The method decomposes an image containing CAC into a synthetic image without CAC and an image showing only CAC. Extensive evaluation was performed in a set of 98 patients, each having rest and stress CTAC scans and a dedicated calcium scoring CT (CSCT). Standard manual calcium scoring in CSCT provided the reference standard. RESULTS: The interscan reproducibility of CAC quantification computed as average absolute relative differences between CTAC and CSCT scan pairs was 75% and 85% at rest and stress using the automatic method compared to 121% and 114% using clinical calcium scoring. Agreement between automatic risk assessment in CTAC and clinical risk categorization in CSCT resulted in linearly weighted kappa of 0.65 compared to 0.40 between CTAC and CSCT using clinically used calcium scoring. CONCLUSION: The increased interscan reproducibility achieved by our method may allow routine cardiovascular risk assessment in CTAC, potentially relieving the need for dedicated CSCT.


Asunto(s)
Enfermedades Cardiovasculares , Enfermedad de la Arteria Coronaria , Humanos , Calcio , Tomografía Computarizada por Tomografía de Emisión de Positrones , Reproducibilidad de los Resultados , Factores de Riesgo , Tomografía Computarizada por Rayos X/métodos , Vasos Coronarios , Factores de Riesgo de Enfermedad Cardiaca , Inteligencia Artificial
2.
Eur Radiol ; 32(1): 152-162, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34255159

RESUMEN

OBJECTIVE: The aim of the current study was, first, to assess the coronary artery calcium (CAC) scoring potential of spectral photon-counting CT (SPCCT) in comparison with computed tomography (CT) for routine clinical protocols. Second, improved CAC detection and quantification at reduced slice thickness were assessed. METHODS: Raw data was acquired and reconstructed with several combinations of reduced slice thickness and increasing strengths of iterative reconstruction (IR) for both CT systems with routine clinical CAC protocols for CT. Two CAC-containing cylindrical inserts, consisting of CAC of different densities and sizes, were placed in an anthropomorphic phantom. A specific CAC was detectable when 3 or more connected voxels exceeded the CAC scoring threshold of 130 Hounsfield units (HU). For all reconstructions, total CAC detectability was compared between both CT systems. Significant differences in CAC quantification (Agatston and volume scores) were assessed with Mann-Whitney U tests. Furthermore, volume scores were compared with the known CAC physical. RESULTS: CAC scores for routine clinical protocols were comparable between SPCCT and CT. SPCCT showed 34% and 4% higher detectability of CAC for the small and large phantom, respectively. At reduced slice thickness, CAC detection increased by 142% and 169% for CT and SPCCT, respectively. In comparison with CT, volume scores from SPCCT were more comparable with the physical volume of the CAC. CONCLUSION: CAC scores using routine clinical protocols are comparable between conventional CT and SPCCT. The increased spatial resolution of SPCCT allows for increased detectability and more accurate CAC volume estimation. KEY POINTS: • Coronary artery calcium scores using routine clinical protocols are comparable between conventional CT and spectral photon-counting CT. • In comparison with conventional CT, increased coronary artery calcium detectability was shown for spectral photon-counting CT due to increased spatial resolution. • Volumes scores were more accurately determined with spectral photon-counting CT.


Asunto(s)
Calcio , Enfermedad de la Arteria Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Humanos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X
3.
Eur Radiol ; 32(5): 3447-3457, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34997284

RESUMEN

OBJECTIVE: The aim of the current study was to systematically assess coronary artery calcium (CAC) detection and quantification for spectral photon-counting CT (SPCCT) in comparison to conventional CT and, in addition, to evaluate the possibility of radiation dose reduction. METHODS: Routine clinical CAC CT protocols were used for data acquisition and reconstruction of two CAC containing cylindrical inserts which were positioned within an anthropomorphic thorax phantom. In addition, data was acquired at 50% lower radiation dose by reducing tube current, and slice thickness was decreased. Calcifications were considered detectable when three adjacent voxels exceeded the CAC scoring threshold of 130 Hounsfield units (HU). Quantification of CAC (as volume and mass score) was assessed by comparison with known physical quantities. RESULTS: In comparison with CT, SPCCT detected 33% and 7% more calcifications for the small and large phantoms, respectively. At reduced radiation dose and reduced slice thickness, small phantom CAC detection increased by 108% and 150% for CT and SPCCT, respectively. For the large phantom size, noise levels interfered with CAC detection. Although comparable between CT and SPCCT, routine protocols CAC quantification showed large deviations (up to 134%) from physical CAC volume. At reduced radiation dose and slice thickness, physical volume overestimations decreased to 96% and 72% for CT and SPCCT, respectively. In comparison with volume scores, mass score deviations from physical quantities were smaller. CONCLUSION: CAC detection on SPCCT is superior to CT, and was even preserved at a reduced radiation dose. Furthermore, SPCCT allows for improved physical volume estimation. KEY POINTS: • In comparison with conventional CT, increased coronary artery calcium detection (up to 156%) for spectral photon-counting CT was found, even at 50% radiation dose reduction. • Spectral photon-counting CT can more accurately measure physical volumes than conventional CT, especially at reduced slice thickness and for high-density coronary artery calcium. • For both conventional and spectral photon-counting CT, reduced slice thickness reconstructions result in more accurate physical mass approximation.


Asunto(s)
Calcinosis , Enfermedad de la Arteria Coronaria , Calcinosis/diagnóstico por imagen , Calcio , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Humanos , Fantasmas de Imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos
4.
J Nucl Cardiol ; 29(4): 1702-1709, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34519008

RESUMEN

BACKGROUND: While [18F]-fluordeoxyglucose ([18F]FDG) uptake is associated with arterial inflammation, [18F]-sodium fluoride ([18F]NaF) is a marker for arterial micro-calcification. We aimed to investigate the prospective correlation between both PET markers over time and whether they are prospectively ([18F]FDG) and retrospectively ([18F]NaF) related to progression of systemic arterial disease in a longitudinal study in patients with type 2 diabetes mellitus (T2DM). METHODS: Baseline [18F]FDG PET/Low Dose (LD) Computed Tomography (CT) scans of ten patients with early T2DM without cardiovascular history (70% men, median age 63 years) were compared with five-year follow-up [18F]NaF/LDCT scans. Systemic activity was expressed as mean target-to-background ratio (meanTBR) by dividing the maximal standardized uptake value (SUVmax) of ten arteries by SUVmean of the caval vein. CT-assessed macro-calcifications were scored visually and expressed as calcified plaque (CP) score. Arterial stiffness was assessed with carotid-femoral pulse wave velocity (PWV). Five-year changes were expressed absolutely with delta (Δ) and relatively with %change. RESULTS: Baseline meanTBR[18F]FDG was strongly correlated with five-year follow-up meanTBR[18F]NaF (r = 0.709, P = .022). meanTBR[18F]NaF correlated positively with ΔCPscore, CPscore at baseline, and follow-up (r = 0.845, P = .002 and r = 0.855, P = .002, respectively), but not with %change in CPscore and PWV. CONCLUSION: This proof-of-concept study demonstrated that systemic arterial inflammation is an important pathogenetic factor in systemic arterial micro-calcification development.


Asunto(s)
Arteritis , Aterosclerosis , Calcinosis , Diabetes Mellitus Tipo 2 , Aterosclerosis/diagnóstico por imagen , Biomarcadores , Diabetes Mellitus Tipo 2/complicaciones , Femenino , Radioisótopos de Flúor , Fluorodesoxiglucosa F18 , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Estudios Prospectivos , Análisis de la Onda del Pulso , Estudios Retrospectivos , Fluoruro de Sodio
5.
Int J Equity Health ; 19(1): 212, 2020 11 27.
Artículo en Inglés | MEDLINE | ID: mdl-33246477

RESUMEN

BACKGROUND: Breast cancer (BC) is the most common cancer in women in the developed world. In order to find developing cancers in an early stage, BC screening is commonly used. In Flanders, screening is performed in and outside an organized breast cancer screening program (BCSP). However, the determinants of BC screening coverage for both screening strategies are yet unknown. OBJECTIVE: To assess the determinants of BC screening coverage in Flanders. METHODS: Reimbursement data were used to attribute a screening status to each woman in the target population for the years 2008-2016. Yearly coverage data were categorized as screening inside or outside BCSP or no screening. Data were clustered by municipality level. A generalized linear equation model was used to assess the determinants of screening type. RESULTS: Over all years and municipalities, the median screening coverage rate inside and outside BCSP was 48.40% (IQR: 41.50-54.40%) and 14.10% (IQR: 9.80-19.80%) respectively. A higher coverage rate outside BSCP was statistically significantly (P < 0.001) associated with more crowded households (OR: 3.797, 95% CI: 3.199-4.508), younger age, higher population densities (OR: 2.528, 95% CI: 2.455-2.606), a lower proportion of unemployed job seekers (OR: 0.641, 95% CI: 0.624-0.658) and lower use of dental care (OR: 0.969, 95% CI: 0.967-0.972). CONCLUSION: Coverage rate of BC screening is not optimal in Flanders. Women with low SES that are characterized by younger age, living in a high population density area, living in crowded households, or having low dental care are less likely to be screened for BC in Flanders. If screened, they are more likely to be screened outside the BCSP.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Detección Precoz del Cáncer/estadística & datos numéricos , Anciano , Bélgica , Detección Precoz del Cáncer/tendencias , Femenino , Humanos , Persona de Mediana Edad
6.
Eur Radiol ; 26(3): 683-92, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26162576

RESUMEN

OBJECTIVES: Renal blood flow (RBF) has been shown to predict disease progression in autosomal dominant polycystic kidney disease (ADPKD). We investigated the feasibility and accuracy of phase-contrast RBF by MRI (RBFMRI) in ADPKD patients with a wide range of estimated glomerular filtration rate (eGFR) values. METHODS: First, we validated RBFMRI measurement using phantoms simulating renal artery hemodynamics. Thereafter, we investigated in a test-set of 21 patients intra- and inter-observer coefficient of variation of RBFMRI. After validation, we measured RBFMRI in a cohort of 91 patients and compared the variability explained by characteristics indicative for disease severity for RBFMRI and RBF measured by continuous hippuran infusion. RESULTS: The correlation in flow measurement using phantoms by phase-contrast MRI was high and fluid collection was high (CCC=0.969). Technical problems that precluded RBFMRI measurement occurred predominantly in patients with a lower eGFR (34% vs. 16%). In subjects with higher eGFRs, variability in RBF explained by disease characteristics was similar for RBFMRI compared to RBFHip, whereas in subjects with lower eGFRs, this was significantly less for RBFMRI. CONCLUSIONS: Our study shows that RBF can be measured accurately in ADPKD patients by phase-contrast, but this technique may be less feasible in subjects with a lower eGFR. KEY POINTS: Renal blood flow (RBF) can be accurately measured by phase-contrast MRI in ADPKD patients. RBF measured by phase-contrast is associated with ADPKD disease severity. RBF measurement by phase-contrast MRI may be less feasible in patients with an impaired eGFR.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Riñón Poliquístico Autosómico Dominante/fisiopatología , Circulación Renal/fisiología , Adulto , Presión Sanguínea/fisiología , Estudios de Cohortes , Medios de Contraste , Progresión de la Enfermedad , Estudios de Factibilidad , Femenino , Tasa de Filtración Glomerular/fisiología , Hemodinámica/fisiología , Humanos , Radioisótopos de Yodo , Ácido Yodohipúrico , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Radiofármacos , Arteria Renal/fisiología , Reproducibilidad de los Resultados
7.
Br J Cancer ; 112(10): 1617-25, 2015 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-25880006

RESUMEN

BACKGROUND: The aim of this study was to evaluate the effect on the number of performed biopsies and costs associated with implementing positron emission tomography (PET) and computed tomography (PET/CT) with 16α-[(18)F]fluoro-17ß-oestradiol (FES) or 2-[(18)F]fluoro-2-deoxy-D-glucose (FDG) as an upfront imaging test for diagnosing metastatic breast cancer (MBC) in comparison with the standard work-up in oestrogen receptor-positive women with symptoms. METHODS: A published computer simulation model was adapted and validated. Three follow-up strategies were evaluated in a simulated cohort of women with primary breast cancer over a 5-year-time horizon: (1) the standard work-up, (2) upfront FES-PET/CT and (3) upfront FDG-PET/CT. The main outcome was the number of avoided biopsies to assess MBC. The costs for all three strategies were calculated based on the number of imaging tests and biopsies. The incremental cost-effectiveness ratio (ICER) to avoid a biopsy was calculated only based on the costs of initial imaging and staging tests. RESULTS: The FES-PET/CT strategy decreased the number of biopsies by 39 ± 9%, while upfront FDG-PET/CT increased the number of biopsies by 38 ± 15% when compared with the standard work-up. Both PET/CT strategies reduced the number of imaging tests and false positives when compared with the standard work-up. The number of false negatives decreased only in the FES-PET/CT strategy. The ICER in the FES-PET/CT strategy per avoided biopsy was 12.1 ± 3.4 thousand Euro. In the FDG-PET/CT strategy, the costs were higher and there were no avoided biopsies as compared with the standard work-up, hence this was an inferior strategy in terms of cost effectiveness. CONCLUSIONS: The number of performed biopsies was lower in the FES-PET/CT strategy at an ICER of 12.1 ± 3.4 thousand Euro per biopsy avoided, whereas the application of the FDG-PET/CT did not reduce the number of biopsies and was more expensive. Whether the FES-PET/CT strategy has additional benefits for patients in terms of therapy management has to be evaluated in clinical studies.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Estradiol/análogos & derivados , Fluorodesoxiglucosa F18 , Receptores de Estrógenos/biosíntesis , Biopsia/economía , Biopsia/métodos , Neoplasias de la Mama/genética , Neoplasias de la Mama/metabolismo , Neoplasias de la Mama/patología , Simulación por Computador , Diagnóstico por Imagen/métodos , Femenino , Humanos , Metástasis de la Neoplasia , Estadificación de Neoplasias/métodos , Tomografía de Emisión de Positrones/métodos , Radiofármacos , Receptores de Estrógenos/genética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos
8.
Curr Oncol ; 22(5): e380-2, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26628880

RESUMEN

Breast cancer screening is a topic of hot debate, and currently no general consensus has been reached on starting and ending ages and screening intervals, in part because of a lack of precise estimations of the benefit-harm ratio. Simulation models are often applied to account for the expected benefits and harms of regular screening; however, the degree to which the model outcomes are reliable is not clear. In a recent systematic review, we therefore aimed to assess the quality of published simulation models for breast cancer screening of the general population. The models were scored according to a framework for qualitative assessment. We distinguished seven original models that utilized a common model type, modelling approach, and input parameters. The models predicted the benefit of regular screening in terms of mortality reduction; and overall, their estimates compared well to estimates of mortality reduction from randomized controlled trials. However, the models did not report on the expected harms associated with regular screening. We found that current simulation models for population breast cancer screening are prone to many pitfalls; their outcomes bear a high overall risk of bias, mainly because of a lack of systematic evaluation of evidence to calibrate the input parameters and a lack of external validation. Our recommendations concerning future modelling are therefore to use systematically evaluated data for the calibration of input parameters, to perform external validation of model outcomes, and to account for both the expected benefits and the expected harms so as to provide a clear balance and cost-effectiveness estimation and to adequately inform decision-makers.

9.
Int J Cardiovasc Imaging ; 40(4): 931-940, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38386192

RESUMEN

Virtual mono-energetic images (VMI) using dual-layer computed tomography (DLCT) enable substantial contrast medium (CM) reductions. However, the combined impact of patient size, tube voltage, and heart rate (HR) on VMI of coronary CT angiography (CCTA) remains unknown. This phantom study aimed to assess VMI levels achieving comparable contrast-to-noise ratio (CNR) in CCTA at 50% CM dose across varying tube voltages, patient sizes, and HR, compared to the reference protocol (100% CM dose, conventional at 120 kVp). A 5 mm artificial coronary artery with 100% (400 HU) and 50% (200 HU) iodine CM-dose was positioned centrally in an anthropomorphic thorax phantom. Horizontal coronary movement was matched to HR (at 0, < 60, 60-75, > 75 bpm), with varying patient sizes simulated using phantom extension rings. Raw data was acquired using a clinical CCTA protocol at 120 and 140 kVp (five repetitions). VMI images (40-70 keV, 5 keV steps) were then reconstructed; non-overlapping 95% CNR confidence intervals indicated significant differences from the reference. Higher CM-dose, reduced VMI, slower HR, higher tube voltage, and smaller patient sizes demonstrated a trend of higher CNR. Regardless of HR, patient size, and tube voltage, no significant CNR differences were found compared to the reference, with 100% CM dose at 60 keV, or 50% CM dose at 40 keV. DLCT reconstructions at 40 keV from 120 to 140 kVp acquisitions facilitate 50% CM dose reduction for various patient sizes and HR with equivalent CNR to conventional CCTA at 100% CM dose, although clinical validation is needed.


Asunto(s)
Angiografía por Tomografía Computarizada , Medios de Contraste , Angiografía Coronaria , Vasos Coronarios , Frecuencia Cardíaca , Fantasmas de Imagen , Valor Predictivo de las Pruebas , Dosis de Radiación , Humanos , Angiografía Coronaria/instrumentación , Angiografía Coronaria/métodos , Angiografía por Tomografía Computarizada/instrumentación , Medios de Contraste/administración & dosificación , Vasos Coronarios/diagnóstico por imagen , Exposición a la Radiación/prevención & control , Interpretación de Imagen Radiográfica Asistida por Computador , Tamaño Corporal
10.
Artículo en Inglés | MEDLINE | ID: mdl-38525588

RESUMEN

PURPOSE: Firstly, to validate automatically and visually scored coronary artery calcium (CAC) on low dose CT (LDCT) scans with a dedicated calcium scoring CT (CSCT) scan. Secondly, to assess the added value of CAC scored from LDCT scans acquired during [15O]-water-PET myocardial perfusion imaging (MPI) on prediction of major adverse cardiac events (MACE). METHODS: 572 consecutive patients with suspected coronary artery disease, who underwent [15O]-water-PET MPI with LDCT and a dedicated CSCT scan were included. In the reference CSCT scans, manual CAC scoring was performed, while LDCT scans were scored visually and automatically using deep learning approach. Subsequently, based on CAC score results from CSCT and LDCT scans, each patient's scan was assigned to one out of five cardiovascular risk groups (0; 1-100; 101-400; 401-1000; >1000) and the agreement in risk group classification between CSCT and LDCT scans was investigated. MACE was defined as a composite of all-cause death, nonfatal myocardial infarction, coronary revascularization, and unstable angina. RESULTS: The agreement in risk group classification between reference CSCT manual scoring and visual/automatic LDCT scoring from LDCT was 0.66 (95% CI: 0.62-0.70) and 0.58 (95% CI: 0.53-0.62), respectively. Based on visual and automatic CAC scoring from LDCT scans, patients with CAC>100 and CAC>400, respectively, were at increased risk of MACE, independently of ischemic information from the [15O]-water-PET scan. CONCLUSIONS: There is a moderate agreement in risk classification between visual and automatic CAC scoring from LDCT and reference CSCT scans. Visual and automatic CAC scoring from LDCT scans improve identification of patients at higher risk of MACE.

11.
Br J Cancer ; 108(8): 1579-86, 2013 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-23579217

RESUMEN

BACKGROUND: There is no consensus on the most effective strategy (mammography or magnetic resonance imaging (MRI)) for screening women with BRCA1 or BRCA2 mutations. The effectiveness and cost-effectiveness of the Dutch, UK and US screening strategies, which involve mammography and MRI at different ages and intervals were evaluated in high-risk women with BRCA1 or BRCA2 mutations. METHODS: Into a validated simulation screening model, outcomes and cost parameters were integrated from published and cancer registry data. Main outcomes were life-years gained and incremental cost-effectiveness ratios. The simulation was situated in the Netherlands as well as in the United Kingdom, comparing the Dutch, UK and US strategies with the population screening as a reference. A discount rate of 3% was applied to both costs and health benefits. RESULTS: In terms of life-years gained, the strategies from least to most cost-effective were the UK, Dutch and US screening strategy, respectively. However, the differences were small. Applying the US strategy in the Netherlands, the costs were €43 800 and 68 800 for an additional life-year gained for BRCA1 and BRCA2, respectively. At a threshold of €20 000 per life-year gained, implementing the US strategy in the Netherlands has a very low probability of being cost-effective. Stepping back to the less-effective UK strategy would save relatively little in costs and results in life-years lost. When implementing the screening strategies in the United Kingdom, the Dutch, as well as the US screening strategy have a high probability of being cost-effective. CONCLUSION: From a cost-effectiveness perspective, the Dutch screening strategy is preferred for screening high-risk women in the Netherlands as well as in the United Kingdom.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/genética , Detección Precoz del Cáncer/métodos , Genes BRCA1 , Genes BRCA2 , Mutación , Adulto , Anciano , Neoplasias de la Mama/economía , Análisis Costo-Beneficio , Detección Precoz del Cáncer/economía , Femenino , Predisposición Genética a la Enfermedad , Humanos , Imagen por Resonancia Magnética/economía , Imagen por Resonancia Magnética/métodos , Mamografía/economía , Mamografía/métodos , Persona de Mediana Edad , Modelos Económicos , Modelos Estadísticos , Países Bajos , Reino Unido , Estados Unidos
12.
Int J Cardiovasc Imaging ; 39(1): 221-231, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36598691

RESUMEN

In computed tomography, coronary artery calcium (CAC) scores are influenced by image reconstruction. The effect of a newly introduced deep learning-based reconstruction (DLR) on CAC scoring in relation to other algorithms is unknown. The aim of this study was to evaluate the effect of four generations of image reconstruction techniques (filtered back projection (FBP), hybrid iterative reconstruction (HIR), model-based iterative reconstruction (MBIR), and DLR) on CAC detectability, quantification, and risk classification. First, CAC detectability was assessed with a dedicated static phantom containing 100 small calcifications varying in size and density. Second, CAC quantification was assessed with a dynamic coronary phantom with velocities equivalent to heart rates of 60-75 bpm. Both phantoms were scanned and reconstructed with four techniques. Last, scans of fifty patients were included and the Agatston calcium score was calculated for all four reconstruction techniques. FBP was used as a reference. In the phantom studies, all reconstruction techniques resulted in less detected small calcifications, up to 22%. No clinically relevant quantification changes occurred with different reconstruction techniques (less than 10%). In the patient study, the cardiovascular risk classification resulted, for all reconstruction techniques, in excellent agreement with the reference (κ = 0.96-0.97). However, MBIR resulted in significantly higher Agatston scores (61 (5.5-435.0) vs. 81.5 (9.25-435.0); p < 0.001) and 6% reclassification rate. In conclusion, HIR and DLR reconstructed scans resulted in similar Agatston scores with excellent agreement and low-risk reclassification rate compared with routine reconstructed scans (FBP). However, caution should be taken with low Agatston scores, as based on phantom study, detectability of small calcifications varies with the used reconstruction algorithm, especially with MBIR and DLR.


Asunto(s)
Calcinosis , Enfermedad de la Arteria Coronaria , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Calcio , Valor Predictivo de las Pruebas , Tomografía Computarizada por Rayos X/métodos , Calcinosis/diagnóstico por imagen , Fantasmas de Imagen , Algoritmos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
13.
Atherosclerosis ; : 117199, 2023 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-37550141

RESUMEN

BACKGROUND AND AIMS: Sodium [18F]fluoride (Na [18F]F) positron emission tomography imaging allows detailed visualization of early arterial micro-calcifications. This study aims to investigate atherosclerosis manifested by micro-calcification, macro-calcification, and aortic stiffness in patients with type 2 diabetes mellitus (T2DM) with and without albuminuria and severely decreased kidney function. METHODS: A cohort was stratified in four groups (N = 10 per group), based on KDIGO categories (G1-5 A1-3). G1-2A1 non-diabetic controls (median [IQR] estimated glomerular filtration rate (eGFR) in mL/min/1.73 m2 91 [81-104]), G1-2A1 with T2DM (eGFR 87 [84-93], and albumin-creatinin-ratio (ACR) in mg/mmol 0.35 [0.25-0.75]), G1-2A3 with T2DM (eGFR 85 [60-103], and ACR 74 [62-122], and G4A3 with T2DM (eGFR 19 [13-27] and ACR 131 [59-304]). RESULTS: Na [18F]F femoral artery grading score differed significantly in the groups with the highest Na [18F]F activity in A3 groups with T2DM (G1-2A3 with T2DM 228 [100-446] and G4A3 with T2DM 198 [113-578]) from the lowest groups of the G1-2A1 with T2DM (33 [0-93]) and in G1-2A1 non-diabetic controls (75 [0-200], p = 0.001). Aortic Na [18F]F activity and femoral artery computed tomography (CT)-assessed macro-calcification was increased in G4A3 with T2DM compared with G1-2A1 with T2DM (47.5 [33.8-73.8] vs. 17.5 [8.8-27.5] (p = 0.006) and 291 [170-511] vs. 12.2 [1.41-44.3] mg (p = 0.032), respectively). Carotid-femoral pulse wave velocity (PWV)-assessed aortic stiffness was significantly higher in both A3 groups with T2DM compared with G1-2A1 with T2DM (11.15 and 12.35 vs. 8.86 m/s, respectively (p = 0.009)). CONCLUSIONS: This study indicates that the presence of severely increased albuminuria in patients with T2DM is cross-sectionally associated with subclinical arterial disease in terms of micro-calcification and aortic stiffness. Additional decrease in kidney function was associated with advanced macro-calcifications.

14.
Br J Surg ; 99(9): 1227-33, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22828861

RESUMEN

BACKGROUND: In the Netherlands, the first 5 years of follow-up after treatment for breast cancer are carried out in hospital with yearly mammography. After this, for patients aged over 60 years who have undergone mastectomy, there is a shift of care to the National Screening Programme (NSP) for mammography every 2 years. After breast-conserving therapy follow-up is perfomed by the general practitioner (GP), with mammography every second year and physical examination annually. The aim of this study was to evaluate the clinical effects and costs of four different strategies for follow-up after breast cancer treatment. METHODS: An extended and validated simulation model for breast cancer follow-up was used. The current guidelines for follow-up (baseline strategy) and three less intensive follow-up strategies were evaluated. The main outcome measure was the detection rate of small tumours (2 cm or smaller) and associated costs for each strategy. RESULTS: Shortening the follow-up time in hospital by shifting care to the NSP or GP after 2 years instead of 5 years of hospital follow-up, lowering the age of referral to the NSP or GP from 60 to 50 years, and termination of annual physical examination by the GP after hospital follow-up did not decrease the detection of small tumours. In addition, a substantial decrease in costs was observed with simplified follow-up. CONCLUSION: Decreasing hospital follow-up time, lowering the age of referral to the NSP or GP, and termination of annual physical examinations would lead to a substantial reduction in costs while maintaining the possibility of detecting small breast cancers.


Asunto(s)
Neoplasias de la Mama/cirugía , Cuidados Posoperatorios/métodos , Adulto , Anciano , Neoplasias de la Mama/economía , Análisis Costo-Beneficio , Femenino , Estudios de Seguimiento , Humanos , Tiempo de Internación , Mastectomía/economía , Mastectomía/rehabilitación , Persona de Mediana Edad , Países Bajos , Cuidados Posoperatorios/economía , Derivación y Consulta , Resultado del Tratamiento
15.
Breast ; 66: 62-68, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36183671

RESUMEN

OBJECTIVES: Mammographic density is a well-defined risk factor for breast cancer and having extremely dense breast tissue is associated with a one-to six-fold increased risk of breast cancer. However, it is questioned whether this increased risk estimate is applicable to current breast density classification methods. Therefore, the aim of this study was to further investigate and clarify the association between mammographic density and breast cancer risk based on current literature. METHODS: Medline, Embase and Web of Science were systematically searched for articles published since 2013, that used BI-RADS lexicon 5th edition and incorporated data on digital mammography. Crude and maximally confounder-adjusted data were pooled in odds ratios (ORs) using random-effects models. Heterogeneity regarding breast cancer risks were investigated using I2 statistic, stratified and sensitivity analyses. RESULTS: Nine observational studies were included. Having extremely dense breast tissue (BI-RADS density D) resulted in a 2.11-fold (95% CI 1.84-2.42) increased breast cancer risk compared to having scattered dense breast tissue (BI-RADS density B). Sensitivity analysis showed that when only using data that had adjusted for age and BMI, the breast cancer risk was 1.83-fold (95% CI 1.52-2.21) increased. Both results were statistically significant and homogenous. CONCLUSIONS: Mammographic breast density BI-RADS D is associated with an approximately two-fold increased risk of breast cancer compared to having BI-RADS density B in general population women. This is a novel and lower risk estimate compared to previously reported and might be explained due to the use of digital mammography and BI-RADS lexicon 5th edition.


Asunto(s)
Densidad de la Mama , Neoplasias de la Mama , Femenino , Humanos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/epidemiología , Neoplasias de la Mama/etiología , Mamografía/métodos , Mama/diagnóstico por imagen , Factores de Riesgo
16.
Breast ; 65: 61-66, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35820298

RESUMEN

OBJECTIVE: To evaluate the effect of irregular screening behaviour on the risk of advanced stage breast cancer at diagnosis in Flanders. METHODS: All women aged 50-69 who were invited to the organized breast cancer screening and diagnosed with breast cancer before age 72 from 2001 to 2018 were included. All prevalent screen and interval cancers within 2 years of a prevalent screen were excluded. Screening behaviour was categorized based on the number of invitations and performed screenings. Four groups were defined: regular, irregular, only-once, and never attenders. Advanced stage cancer was defined as a stage III + breast cancer. The association between screening regularity and breast cancer stage at diagnosis was evaluated in multivariable logistic regression models, taking age of diagnosis and socio-economic status into account. RESULTS: In total 13.5% of the 38,005 breast cancer cases were diagnosed at the advanced stage. Compared to the regular attenders, the risk of advanced stage breast cancer for the irregular attenders, women who participated only-once, and never attenders was significantly higher with ORadjusted:1.17 (95%CI:1.06-1.29) and ORadjusted:2.18 (95%CI:1.94-2.45), and ORadjusted:5.95 (95%CI:5.33-6.65), respectively. CONCLUSIONS: In our study, never attenders were nearly six times more likely to be diagnosed with advanced stage breast cancer than regular attenders, which was much higher than the estimates published thus far. An explanation for this is that the ever screened women is a heterogeneous group regarding the participation profiles which also includes irregular and only-once attenders. The benefit of regular screening should be informed to all women invited for screening.


Asunto(s)
Neoplasias de la Mama , Mamografía , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/epidemiología , Neoplasias de la Mama/prevención & control , Detección Precoz del Cáncer , Femenino , Humanos , Tamizaje Masivo , Investigación
17.
Front Oncol ; 12: 817222, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35311110

RESUMEN

Background: Breast cancer (BC) screening can be performed in a screening program (BCSP) or in opportunistic screening. The existing reviews on the determinants of non-participation depend on self-reported data which may be biased. Furthermore, no distinction was made between the probably different determinants of both screening strategies. Objective: To find the determinants of non-participation in BCSP by means of a meta-analysis. Methods: PubMed, Embase, and Web of Science were searched for observational studies which quantified factors associated with non-participation in BCSP in a general population. Studies on opportunistic screening and studies using self-reported data were excluded. A random-effect model was used to calculate pooled odds ratios (ORs) and 95% confidence intervals (CIs). Potential sources of heterogeneity were explored by stratification of the results. Results: Twenty-nine studies with in a total of 20,361,756 women were included. Low income (OR: 1.20, 95% CI: 1.10-1.30), low education (OR: 1.18, 95% CI: 1.05-1.32), living far from an assigned screening unit (OR: 1.15, 95% CI: 1.07-1.24), being immigrant (OR: 2.64, 95% CI: 2.48-2.82), and having a male family doctor (OR: 1.43, 95% CI: 1.20-1.61) was associated with higher non-participation in screening. Reminders sent to non-attenders and estimations of ORs (adjusted or not) partly explained substantial heterogeneity. Conclusion: In this meta-analysis excluding studies on the non-participation in opportunistic screening, or with self-reported data on non-participation, the well-known determinants for non-participation are still significant, but less strong. This analysis only supports the relevance of meta-analysis of studies with registered non-participation in a BCSP. Systematic Review Registration: PROSPERO, CRD42020154016.

18.
Eur Radiol ; 21(8): 1733-8, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21432022

RESUMEN

OBJECTIVES: To assess the feasibility of computed tomography (CT) based thermometry during interstitial laser heating in the bovine liver. METHODS: Four freshly exercised cylindrical blocks of bovine tissue were heated using a continuous laser of Nd:YAG (wavelength: 1064 nm, active length: 30 mm, power: 10-30 W). All tissues were imaged at least once before and 7 times during laser heating using CT and temperatures were simultaneously measured with 5 calibrated thermal sensors. The dependency of the average CT numbers as a function of temperature was analysed with regression analysis and a CT thermal sensitivity was derived. RESULTS: During laser heating, the growing hypodense area was observed around the laser source and that area showed an increase as a function of time. The formation of hypodense area was caused by declining in CT numbers at increasing temperatures. The regression analysis showed an inverse linear dependency between temperature and average CT number with -0.65 ± 0.048 HU/°C (R(2) = 0.75) for the range of 18-85°C in bovine liver. CONCLUSIONS: The non-invasive CT based thermometry during interstitial laser heating is feasible in the bovine liver. CT based thermometry could be further developed and may be of potential use during clinical LITT of the liver.


Asunto(s)
Ablación por Catéter/métodos , Hipertermia Inducida , Láseres de Estado Sólido , Hígado/diagnóstico por imagen , Hígado/cirugía , Tomografía Computarizada por Rayos X/métodos , Animales , Bovinos , Estudios de Factibilidad , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Análisis de Regresión
19.
Trials ; 22(1): 805, 2021 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-34781993

RESUMEN

INTRODUCTION: Percutaneous nephrolithotomy (PCNL) is the standard surgical treatment method for large kidney stones. Its aim is to achieve a stone-free status, since any residual fragments (RFs) after PCNL are likely to cause additional morbidity or stone growth. Enhancing intraoperative detectability of RFs could lead to increased stone-free rates and decreased re-intervention rates. Cone beam computed tomography (CBCT) has recently been introduced in urology as a feasible method for intraoperatively imaging RFs. The aim of this trial is to determine the added value of CBCT in percutaneous nephrolithotomy, by measuring differences in stone-related morbidity for patients with procedures in which a CBCT is used versus patients with procedures without the use of CBCT. METHODS: The CAPTURE trial is an investigator-initiated single-center, randomized controlled trial (RCT) in adult patients who have an indication for percutaneous nephrolithotomy. A contemporary percutaneous nephrolithotomy is performed. Once the surgeon is convinced of a stone-free status by means of fluoroscopy and nephroscopy, randomization allocates patients to either the study group in whom an intraoperative CBCT scan is performed or to the control group in whom no intraoperative CBCT scan is performed. The main endpoint is the stone-free status as assessed four weeks postoperatively by low-dose non-contrast abdominal CT, as a standard follow-up procedure. Secondary endpoints include the number of PCNL procedures required and the number of stone-related events (SREs) registered. The total study population will consist of 320 patients that undergo PCNL and are eligible for randomization for an intraoperative CBCT scan. DISCUSSION: We deem a randomized controlled trial to be the most effective and reliable method to assess the efficacy of CBCT in PCNL. Though some bias may occur due to the impossibility of blinding the urologist at randomization, we estimate that the pragmatic nature of the study, standardized circumstances, and follow-up methods with pre-defined outcome measures will result in a high level of evidence. TRIAL REGISTRATION: Netherlands Trial Register (NTR) NL8168 , ABR NL70728.042.19. Registered on 15 October 2019. Prospectively registered.


Asunto(s)
Cálculos Renales , Nefrolitotomía Percutánea , Adulto , Tomografía Computarizada de Haz Cónico , Progresión de la Enfermedad , Humanos , Cálculos Renales/diagnóstico por imagen , Cálculos Renales/cirugía , Nefrolitotomía Percutánea/efectos adversos , Países Bajos , Ensayos Clínicos Controlados Aleatorios como Asunto , Resultado del Tratamiento
20.
Eur Radiol ; 19(3): 577-83, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18953545

RESUMEN

To compare magnetic resonance imaging (MRI), 64-slice multi-detector computed tomography (MDCT) and dual-source computed tomography (DSCT) in assessing global function parameters using a moving heart phantom. A moving heart phantom with known volumes (215-258 ml) moving at 50-100 beats per minute was examined by three different imaging modalities using clinically implemented scanning protocols. End-diastolic and end-systolic volumes were calculated by two experienced observers using dedicated post-processing tools. Ejection fraction (EF) and cardiac output (CO) were calculated and mutually compared using Bland-Altman plots. MRI underestimated the ejection EF by 16.1% with a Bland-Altman interval (B-A) of [-4.35 (-2.48) -0.60]. Sixty-four-slice MDCT overestimated the EF by 2.6% with a relatively wide B-A interval of [-3.40 (0.40) 4.20]. DSCT deviated the least from the known phantom volumes, underestimating the volumes by 0.8% with a B-A interval of [-1.17 (-0.13) 0.91]. CO analysis showed similar results. Furthermore, a good correlation was found between DSCT and MRI for EF and CO results. MRI systematically underestimates functional cardiac parameters, ejection fraction and cardiac output of a moving heart phantom. Sixty-four-slice MDCT underestimates or overestimates these functional parameters depending on the heart rate because of limited spatial resolution. DSCT deviates the least from these functional parameters compared to MRI, EBT and 64-slice MDCT.


Asunto(s)
Corazón/diagnóstico por imagen , Corazón/fisiología , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Antropometría , Diseño de Equipo , Humanos , Movimiento , Variaciones Dependientes del Observador , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Reproducibilidad de los Resultados , Volumen Sistólico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA