Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Ann Emerg Med ; 83(5): 467-476, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38276937

RESUMEN

The Clinical Emergency Data Registry (CEDR) is a qualified clinical data registry that collects data from participating emergency departments (EDs) in the United States for quality measurement, improvement, and reporting purposes. This article aims to provide an overview of the data collection and validation process, describe the existing data structure and elements, and explain the potential opportunities and limitations for ongoing and future research use. CEDR data are primarily collected for quality reporting purposes and are obtained from diverse sources, including electronic health records and billing data that are de-identified and stored in a secure, centralized database. The CEDR data structure is organized around clinical episodes, which contain multiple data elements that are standardized using common data elements and are mapped to established terminologies to enable interoperability and data sharing. The data elements include patient demographics, clinical characteristics, diagnostic and treatment procedures, and outcomes. Key limitations include the limited generalizability due to the selective nature of participating EDs and the limited validation and completeness of data elements not currently used for quality reporting purposes, including demographic data. Nonetheless, CEDR holds great potential for ongoing and future research in emergency medicine due to its large-volume, longitudinal, near real-time, clinical data. In 2021, the American College of Emergency Physicians authorized the transition from CEDR to the Emergency Medicine Data Institute, which will catalyze investments in improved data quality and completeness for research to advance emergency care.


Asunto(s)
Registros Electrónicos de Salud , Servicios Médicos de Urgencia , Humanos , Estados Unidos , Sistema de Registros , Recolección de Datos , Servicio de Urgencia en Hospital
2.
Mo Med ; 120(2): 114-120, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37091932

RESUMEN

The Agency for Healthcare Research and Quality (AHRQ) report "Diagnostic Errors in the Emergency Department" generated significant mass media interest with negative implications for the safety of contemporary emergency care. The assumptions and methodology underlying this report are problematic, while multiple ongoing efforts to improve the quality and quantity of diagnostic research are missed, neglected, or ignored. The AHRQ report identifies reasonable target diseases for targeting diagnostic quality improvement efforts, as well as viable methods by which to measure any initiatives impact on diagnostic error. We note additional opportunities to improve the status quo by funding emergency department-based diagnostic research and healthcare system-level patient safety research and highlighting innovative approaches to diagnostic science within emergency medicine.


Asunto(s)
Medicina de Emergencia , Investigación sobre Servicios de Salud , Estados Unidos , Humanos , Errores Diagnósticos , United States Agency for Healthcare Research and Quality
3.
Ann Emerg Med ; 80(6): 528-538, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35927115

RESUMEN

STUDY OBJECTIVE: The Emergency Department Trigger Tool (EDTT) is a novel approach to adverse event detection in the ED. We previously described the derivation, validation, and high-level performance of this tool. Here we further detail adverse events detected to demonstrate the utility of the EDTT and how it might be used for quality improvement. METHODS: This is a secondary analysis of data from a retrospective observational study. We ran the EDTT (a computerized query for triggers) on 13 months of ED visit data, reviewing 5,582 selected records using a typical 2-tiered trigger tool approach. The adverse events detected were categorized by place of occurrence (in the ED versus present on arrival), severity, omission/commission, and type using a taxonomy with categories, subcategories, and up to 3 cross-cutting modifiers. We present adverse event data in detail, focusing in turn on each of these descriptors (severity, event types, and cross-cutting themes) and highlight opportunities identified for targeted improvement. RESULTS: We identified 458 adverse events occurring in the ED for a 13-month period, 10% of which required urgent intervention. Nearly all (90%) were acts of commission. Events resulting in harm were most often related to medications administered and patient care. Common cross-cutting event types included adverse events related to bleeding, opioids, and the use of propofol. Most adverse events (80%) led to temporary harm. CONCLUSION: The EDTT identifies a broad spectrum of adverse event types, allowing a review by severity, frequency, and type to better understand existing levels of harm in the ED and identify targets for quality improvement. A multicenter study of the EDTT is currently underway, which will contribute additional power and assess generalizability.


Asunto(s)
Servicio de Urgencia en Hospital , Mejoramiento de la Calidad , Humanos , Estudios Retrospectivos , Analgésicos Opioides
4.
J Intensive Care Med ; 37(9): 1215-1222, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35723623

RESUMEN

Background: Over 5 million central venous catheters (CVCs) are placed annually. Pneumothorax and catheter malpositioning are common adverse events (AE) that requires attention. This study aims to evaluate local practices of mechanical complication frequency, type, and subsequent intervention(s) related to mechanical AE with an emphasis on catheter malpositioning. Methods: This is a retrospective review of CVC placements in a tertiary hospital setting from 1/2013 to 12/2013. Pneumothorax and CVC positioning were evaluated on post-insertion chest x-ray (CXR). Malposition was defined as unintended placement of the catheter in a vessel other than the intended superior vena cava on CXR. Catheter reposition was defined as radiographic evidence of a new catheter with removal of the old catheter less than 24hrs after initial placement. Data points analyzed included pneumothorax and thoracostomy rate, CVC malposition frequency, catheter reposition rate, catheter duration, and incidence of complications such as catheter associated venous thrombosis. Result: Among 2045 eligible CVC insertions, pneumothoraces occurred in 14 (0.7%; 95%CI 0.38, 1.17) and malpositions were identified in 275 (13.4%; 95% CI 12.3, 15.3). The proportion of pneumothoraces that required tube thoracostomy was 57%. The proportion of CVCs with malposition that were removed or replaced within 24h was 32.7%. "Malpositioned" catheters that were left in place by the clinical team (n = 185) had an average catheter duration of 8.2 days (95% CI 7.2, 9.3) versus 7.2 days (95% CI 6.17, 8.23) for catheters that were replaced after initial malposition (p = 0.14, t test). The incidence of venous thrombosis in repositioned "malpositioned" catheters was 7.8% versus 4.9% for "malpositioned" catheters that were left in place. Conclusions: Clinically significant catheter malposition and pneumothorax after CVC insertion are low. In this study, replaced and non-replaced "malpositioned" catheters had similar catheter duration and rates of complications, challenging the current dogma of CVC malposition practice.


Asunto(s)
Cateterismo Venoso Central , Catéteres Venosos Centrales , Neumotórax , Cateterismo Venoso Central/efectos adversos , Catéteres Venosos Centrales/efectos adversos , Humanos , Neumotórax/etiología , Radiografía Torácica/efectos adversos , Vena Cava Superior
5.
Ann Emerg Med ; 76(2): 230-240, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31623935

RESUMEN

STUDY OBJECTIVE: Trigger tools improve surveillance for harm by focusing reviews on records with "triggers" whose presence increases the likelihood of an adverse event. We refine and automate a previously developed emergency department (ED) trigger tool and present record selection strategies to further optimize yield. METHODS: We specified 97 triggers for extraction from our electronic medical record, identifying 76,894 ED visits with greater than or equal to 1 trigger. We reviewed 1,726 records with greater than or equal to 1 trigger, following a standard trigger tool review process. We validated query performance against manual review and evaluated individual triggers, retaining only those associated with adverse events in the ED. We explored 2 approaches to enhance record selection: on number of triggers present and using trigger weights derived with least absolute shrinkage and selection operator logistic regression. RESULTS: The automated query performed well compared with manual review (sensitivity >70% for 80 triggers; specificity >92% for all). Review yielded 374 adverse events (21.6 adverse events per 100 records). Thirty triggers were associated with risk of harm in the ED. An estimated 10.3% of records with greater than 1 of these triggers would include an adverse event in the ED. Selecting only records with greater than or equal to 4 or greater than or equal to 9 triggers improves yield to 17% and 34.8%, respectively, whereas use of least absolute shrinkage and selection operator trigger weighting enhances the yield to as high as 52%. CONCLUSION: The ED trigger tool is a promising approach to improve yield, scope, and efficiency of review for all-cause harm in emergency medicine. Beginning with a broad set of candidate triggers, we validated a computerized query that eliminates the need for manual screening for triggers and identified a refined set of triggers associated with adverse events in the ED. Review efficiency can be further enhanced with enhanced record selection.


Asunto(s)
Errores Médicos/estadística & datos numéricos , Daño del Paciente/estadística & datos numéricos , Seguridad del Paciente , Garantía de la Calidad de Atención de Salud , Adulto , Anciano , Registros Electrónicos de Salud , Servicio de Urgencia en Hospital , Femenino , Humanos , Modelos Logísticos , Masculino , Tamizaje Masivo , Errores de Medicación/estadística & datos numéricos , Persona de Mediana Edad , Medición de Riesgo , Adulto Joven
6.
N Engl J Med ; 371(12): 1100-10, 2014 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-25229916

RESUMEN

BACKGROUND: There is a lack of consensus about whether the initial imaging method for patients with suspected nephrolithiasis should be computed tomography (CT) or ultrasonography. METHODS: In this multicenter, pragmatic, comparative effectiveness trial, we randomly assigned patients 18 to 76 years of age who presented to the emergency department with suspected nephrolithiasis to undergo initial diagnostic ultrasonography performed by an emergency physician (point-of-care ultrasonography), ultrasonography performed by a radiologist (radiology ultrasonography), or abdominal CT. Subsequent management, including additional imaging, was at the discretion of the physician. We compared the three groups with respect to the 30-day incidence of high-risk diagnoses with complications that could be related to missed or delayed diagnosis and the 6-month cumulative radiation exposure. Secondary outcomes were serious adverse events, related serious adverse events (deemed attributable to study participation), pain (assessed on an 11-point visual-analogue scale, with higher scores indicating more severe pain), return emergency department visits, hospitalizations, and diagnostic accuracy. RESULTS: A total of 2759 patients underwent randomization: 908 to point-of-care ultrasonography, 893 to radiology ultrasonography, and 958 to CT. The incidence of high-risk diagnoses with complications in the first 30 days was low (0.4%) and did not vary according to imaging method. The mean 6-month cumulative radiation exposure was significantly lower in the ultrasonography groups than in the CT group (P<0.001). Serious adverse events occurred in 12.4% of the patients assigned to point-of-care ultrasonography, 10.8% of those assigned to radiology ultrasonography, and 11.2% of those assigned to CT (P=0.50). Related adverse events were infrequent (incidence, 0.4%) and similar across groups. By 7 days, the average pain score was 2.0 in each group (P=0.84). Return emergency department visits, hospitalizations, and diagnostic accuracy did not differ significantly among the groups. CONCLUSIONS: Initial ultrasonography was associated with lower cumulative radiation exposure than initial CT, without significant differences in high-risk diagnoses with complications, serious adverse events, pain scores, return emergency department visits, or hospitalizations. (Funded by the Agency for Healthcare Research and Quality.).


Asunto(s)
Nefrolitiasis/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adolescente , Adulto , Distribución por Edad , Anciano , Investigación sobre la Eficacia Comparativa , Servicio de Urgencia en Hospital , Femenino , Hospitalización/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Ultrasonografía , Adulto Joven
7.
Ann Emerg Med ; 69(5): 587-599, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-27317304

RESUMEN

Patients with inflammatory bowel disease who experience abdominal pain and gastrointestinal symptoms often seek care in the emergency department (ED). These patients commonly undergo abdominopelvic computed tomography (CT) as part of their evaluation, and the rate of imaging appears to be increasing without a corresponding increase in identification of clinically actionable findings or effect on disposition. Studies demonstrate that the yield of CT tends to be fairly high. Yet, because inflammatory bowel disease is often diagnosed at an early age, these patients are repeatedly imaged during their lifetime, a subset of whom accumulate high levels of ionizing radiation exposure, increasing their risk of cancer. This compounds an already increased risk of cancer in these patients because of inflammatory bowel disease alone. Lack of intimate knowledge of a patient's disease phenotype and disease progression contributes to uncertainty in distinguishing between an inflammatory exacerbation; a complication such as obstruction, abscess, perforation, fistula, or stricture; and a noninflammatory-bowel-disease-related condition. This uncertainty can lead to overuse of imaging with CT. Limited availability of and lack of awareness of alternate imaging modalities and strategies may prevent providers from pursuing strategies that avoid ionizing radiation. In this article, we review options for imaging inflammatory bowel disease patients in the ED and attempts undertaken to risk stratify these patients, and we discuss ways in which details of a patient's disease might guide imaging decisionmaking.


Asunto(s)
Servicio de Urgencia en Hospital , Enfermedades Inflamatorias del Intestino/diagnóstico por imagen , Colitis Ulcerosa/diagnóstico por imagen , Enfermedad de Crohn/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Exposición a la Radiación , Tomografía Computarizada por Rayos X/efectos adversos , Ultrasonografía
8.
J Emerg Med ; 51(2): 136-9, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27301666

RESUMEN

BACKGROUND: Anti-N-methyl-d-aspartate (NMDA) receptor autoimmune encephalitis is a newly identified form of encephalitis whose incidence is on the rise. Awareness of this condition and symptom recognition are key to early diagnosis and prompt treatment, which may alter the course of the disease. CASE REPORT: A 35-year-old woman presented to our Emergency Department (ED) with lethargy, bizarre behavior, agitation, confusion, memory deficits, and word-finding difficulties. Her symptoms and evaluation were potentially consistent with a primary psychiatric disorder, but the absence of frank psychosis and presence of neurologic features related to memory and cognition prompted other considerations. In the ED we performed a lumbar puncture, and in addition to routine studies, ordered anti-NMDAR antibody screening. The screening studies returned positive, leading to treatment with glucocorticoids and intravenous immune globulin and resulting in improvement to near baseline function. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Although anti-NMDAR encephalitis is relatively uncommon, reports of this previously unrecognized condition are increasing, with an unclear true incidence of disease. Emergency providers should consider this diagnosis in their differential for patients presenting with new neuropsychiatric symptoms, particularly in young women. Prompt treatment leads to near complete neurologic recovery in 75% of patients, whereas delays in diagnosis and treatment may be associated with worse outcomes including death.


Asunto(s)
Encefalitis Antirreceptor N-Metil-D-Aspartato/complicaciones , Servicio de Urgencia en Hospital , Receptores de N-Metil-D-Aspartato/análisis , Adulto , Encefalitis Antirreceptor N-Metil-D-Aspartato/diagnóstico , Encefalitis Antirreceptor N-Metil-D-Aspartato/inmunología , Anticuerpos/análisis , Diagnóstico Diferencial , Diagnóstico Precoz , Femenino , Humanos , Trastornos Psicóticos/diagnóstico , Trastornos Psicóticos/etiología
9.
Ann Emerg Med ; 65(4): 387-95, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25443989

RESUMEN

Performance measures are increasingly important to guide meaningful quality improvement efforts and value-based reimbursement. Populations included in most current hospital performance measures are defined by recorded diagnoses using International Classification of Diseases, Ninth Revision codes in administrative claims data. Although the diagnosis-centric approach allows the assessment of disease-specific quality, it fails to measure one of the primary functions of emergency department (ED) care, which involves diagnosing, risk stratifying, and treating patients' potentially life-threatening conditions according to symptoms (ie, chief complaints). In this article, we propose chief complaint-based quality measures as a means to enhance the evaluation of quality and value in emergency care. We discuss the potential benefits of chief complaint-based measures, describe opportunities to mitigate challenges, propose an example measure set, and present several recommendations to advance this paradigm in ED-based performance measurement.


Asunto(s)
Servicios Médicos de Urgencia/normas , Garantía de la Calidad de Atención de Salud/métodos , Dolor en el Pecho/diagnóstico , Dolor en el Pecho/epidemiología , Dolor en el Pecho/terapia , Humanos , Mejoramiento de la Calidad , Indicadores de Calidad de la Atención de Salud
10.
Acad Emerg Med ; 31(6): 564-575, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38497320

RESUMEN

OBJECTIVES: We previously described derivation and validation of the emergency department trigger tool (EDTT) for adverse event (AE) detection. As the first step in our multicenter study of the tool, we validated our computerized screen for triggers against manual review, establishing our use of this automated process for selecting records to review for AEs. METHODS: This is a retrospective observational study of visits to three urban, academic EDs over 18 months by patients ≥ 18 years old. We reviewed 912 records: 852 with at least one of 34 triggers found by the query and 60 records with none. Two first-level reviewers per site each manually screened for triggers. After completion, computerized query results were revealed, and reviewers could revise their findings. Second-level reviewers arbitrated discrepancies. We compare automated versus manual screening by positive and negative predictive values (PPVs, NPVs), present population trigger frequencies, proportions of records triggered, and how often manual ratings were changed to conform with the query. RESULTS: Trigger frequencies ranged from common (>25%) to rare (1/1000) were comparable at U.S. sites and slightly lower at the Canadian site. Proportions of triggered records ranged from 31% to 49.4%. Overall query PPV was 95.4%; NPV was 99.2%. PPVs for individual trigger queries exceeded 90% for 28-31 triggers/site and NPVs were >90% for all but three triggers at one site. Inter-rater reliability was excellent, with disagreement on manual screening results less than 5% of the time. Overall, reviewers amended their findings 1.5% of the time when discordant with query findings, more often when the query was positive than when negative (47% vs. 23%). CONCLUSIONS: The EDTT trigger query performed very well compared to manual review. With some expected variability, trigger frequencies were similar across sites and proportions of triggered records ranged 31%-49%. This demonstrates the feasibility and generalizability of implementing the EDTT query, providing a solid foundation for testing the triggers' utility in detecting AEs.


Asunto(s)
Servicio de Urgencia en Hospital , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Canadá , Servicio de Urgencia en Hospital/estadística & datos numéricos , Errores Médicos/estadística & datos numéricos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Estados Unidos
11.
Ann Emerg Med ; 62(4): 399-407, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23796627

RESUMEN

The Health Information Technology for Economic and Clinical Health Act of 2009 and the Centers for Medicare & Medicaid Services "meaningful use" incentive programs, in tandem with the boundless additional requirements for detailed reporting of quality metrics, have galvanized hospital efforts to implement hospital-based electronic health records. As such, emergency department information systems (EDISs) are an important and unique component of most hospitals' electronic health records. System functionality varies greatly and affects physician decisionmaking, clinician workflow, communication, and, ultimately, the overall quality of care and patient safety. This article is a joint effort by members of the Quality Improvement and Patient Safety Section and the Informatics Section of the American College of Emergency Physicians. The aim of this effort is to examine the benefits and potential threats to quality and patient safety that could result from the choice of a particular EDIS, its implementation and optimization, and the hospital's or physician group's approach to continuous improvement of the EDIS. Specifically, we explored the following areas of potential EDIS safety concerns: communication failure, wrong order-wrong patient errors, poor data display, and alert fatigue. Case studies are presented that illustrate the potential harm that could befall patients from an inferior EDIS product or suboptimal execution of such a product in the clinical environment. The authors have developed 7 recommendations to improve patient safety with respect to the deployment of EDISs. These include ensuring that emergency providers actively participate in selection of the EDIS product, in the design of processes related to EDIS implementation and optimization, and in the monitoring of the system's ongoing success or failure. Our recommendations apply to emergency departments using any type of EDIS: custom-developed systems, best-of-breed vendor systems, or enterprise systems.


Asunto(s)
Servicio de Urgencia en Hospital/normas , Sistemas de Información en Hospital/normas , Seguridad del Paciente/normas , Alarmas Clínicas , Comunicación , Registros Electrónicos de Salud/normas , Humanos , Errores Médicos/prevención & control , Calidad de la Atención de Salud/normas
12.
Proc Natl Acad Sci U S A ; 107(16): 7263-8, 2010 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-20360559

RESUMEN

Translation of the hepatitis C virus (HCV) RNA is initiated from a highly structured internal ribosomal entry site (IRES) in the 5' untranslated region (5' UTR) of the RNA genome. An important structural feature of the native RNA is an approximately 90 degrees helical bend localized to domain IIa that positions the apical loop of domain IIb of the IRES near the 40S ribosomal E-site to promote eIF2-GDP release, facilitating 80S ribosome assembly. We report here the NMR structure of a domain IIa construct in complex with a potent small-molecule inhibitor of HCV replication. Molecular dynamics refinement in explicit solvent and subsequent energetic analysis indicated that each inhibitor stereoisomer bound with comparable affinity and in an equivalent binding mode. The in silico analysis was substantiated by fluorescence-based assays showing that the relative binding free energies differed by only 0.7 kcal/mol. Binding of the inhibitor displaces key nucleotide residues within the bulge region, effecting a major conformational change that eliminates the bent RNA helical trajectory, providing a mechanism for the antiviral activity of this inhibitor class.


Asunto(s)
Hepacivirus/genética , ARN Viral/química , Secuencia de Bases , Factor 2 Eucariótico de Iniciación/química , Hepacivirus/metabolismo , Concentración de Iones de Hidrógeno , Espectroscopía de Resonancia Magnética/métodos , Conformación Molecular , Datos de Secuencia Molecular , Conformación de Ácido Nucleico , Unión Proteica , Conformación Proteica , ARN Ribosómico/química , Solventes/química , Electricidad Estática , Estereoisomerismo
13.
J Emerg Med ; 44(1): 155-60, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21835572

RESUMEN

BACKGROUND: Failure to detect pregnancy in the emergency department (ED) can have important consequences. Urine human chorionic gonadotropin (uhCG) point-of-care (POC) assays are valued for rapidly detecting early pregnancy with high sensitivity. However, under certain conditions, POC uhCG tests can fail to detect pregnancy. OBJECTIVES: In investigating a series of late first-trimester false-negative pregnancy tests in our ED, a novel and distinct causative phenomenon was recently elucidated in our institution. We discuss uhCG POC tests, review our false-negative rate, and describe mechanisms for false negatives and potential remedies. DISCUSSION: The false-negative POC uhCG rate is very low, but in the setting of a large volume of tests, the numbers are worth consideration. In positive uhCG POC tests, free and fixed antibodies bind hCG to form a "sandwich"; hCG is present in several variant forms that change in their concentrations at different stages of pregnancy. When in excess, intact hCG can saturate the antibodies, preventing sandwich formation (hook effect phenomenon). Some assays may include an antibody that does not recognize certain variants present in later stages of pregnancy. When this variant is in excess, it can bind one antibody avidly and the other not at all, resulting in a false-negative test (hook-like phenomenon). In both situations, dilution is key to an accurate test. CONCLUSIONS: Manufacturers should consider that uhCG tests are routinely used at many stages of pregnancy. Characterizing uhCG variants recognized by their tests and eliminating lot-to-lot variability may help improve uhCG test performance. Clinicians need to be aware of and familiarize themselves with the limitations of the specific type of uhCG POC tests used in their practice, recognizing that under certain circumstances, false-negative tests can occur.


Asunto(s)
Gonadotropina Coriónica/orina , Servicio de Urgencia en Hospital , Sistemas de Atención de Punto , Pruebas de Embarazo/métodos , Adolescente , Adulto , Biomarcadores/orina , Reacciones Falso Negativas , Femenino , Humanos , Embarazo , Pruebas de Embarazo/normas , Primer Trimestre del Embarazo/orina , Ultrasonografía Prenatal , Urinálisis/métodos , Adulto Joven
14.
J Patient Saf ; 19(2): 59-66, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36715980

RESUMEN

OBJECTIVES: Near misses include conditions with potential for harm, intercepted medical errors, and events requiring monitoring or intervention to prevent harm. Little is reported on near misses or their importance for quality and safety in the emergency department (ED). METHODS: This is a secondary evaluation of data from a retrospective study of the ED Trigger Tool (EDTT) at an urban, academic ED (data from October 1, 2014, to October 31, 2015; 92,859 eligible visits). All patients 18 years and older completing a visit were eligible. We ran the EDTT, a computerized query for triggers on 13 months of ED visit data, reviewing 5582 selected records using a 2-tiered approach. Events were categorized by occurrence (ED vs present on arrival [POA]), severity, omission/commission, and type, using a taxonomy with categories, subcategories, and cross-cutting modifiers. RESULTS: We identified 1458 ED near misses in 1269 of 5582 records (22.7%) and 80 near misses that were POA. Patient care events represented most ED near misses, including delays in diagnosis, treatment, and failure to monitor, primarily driven by ED boarding and crowding. Medication events were second most common (17%), including 80 medication administration errors. Of 80 POA events, 42% were related to overanticoagulation. We estimate that 19.3% of all ED visits include a near miss. CONCLUSIONS: Near-miss events are relatively common (22.7% of our sample, 19.3% in the population) and are associated with an increased risk for an adverse event. Most events were patient care related (77%) involving delays due to crowding and ED boarding followed by medication administration errors. The EDTT is a high-yield approach for detecting important near misses and latent system deficiencies that impact patient safety.


Asunto(s)
Potencial Evento Adverso , Humanos , Estudios Retrospectivos , Errores Médicos/prevención & control , Servicio de Urgencia en Hospital , Seguridad del Paciente
15.
J Am Coll Radiol ; 20(12): 1250-1257, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37805010

RESUMEN

PURPOSE: Imaging clinical decision support (CDS) is designed to assist providers in selecting appropriate imaging studies and is now federally required. The aim of this study was to understand the effect of CDS on decisions and workflows in the emergency department (ED). METHODS: The authors' institution's order entry platform serves up structured indications for imaging orders. Imaging orders are scored by CDS on the basis of appropriate use criteria (AUC). CDS triggers alerts for imaging orders with low AUC scores. Because free text alone cannot be scored by CDS, an artificial intelligence predictive text (AIPT) module was implemented to guide the selection of structured indications when free-text indications are entered. A total of 17,355 imaging orders in the ED over 6 months were retrospectively analyzed. RESULTS: CDS alerts for low AUC scores were triggered for 3% of all imaging study orders (522 of 17,355). Providers spent an average of 24 seconds interacting with alerts. In 18 of 522 imaging orders with alerts, alternative studies were ordered. After AIPT implementation, the percentage of unscored studies significantly decreased from 81% to 45% (P < .001). CONCLUSIONS: In a quaternary academic ED, CDS alerts triggered by low AUC scores caused minimal increase in time spent on imaging order entry but had a relatively marginal impact on imaging study selection. AIPT implementation increased the number of scored studies and could potentially enhance CDS effects. CDS implementation enables the collection of novel data regarding which imaging studies receive low AUC scores. Future work could include exploring alternative models of CDS implementation to maximize its impact.


Asunto(s)
Sistemas de Apoyo a Decisiones Clínicas , Sistemas de Entrada de Órdenes Médicas , Humanos , Estudios Retrospectivos , Inteligencia Artificial , Servicio de Urgencia en Hospital
16.
J Vasc Access ; 24(5): 879-888, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34763555

RESUMEN

BACKGROUND: The adoption rate of point of care ultrasound (POCUS) for the confirmation of central venous catheter (CVC) positioning and exclusion of post procedure pneumothorax is low despite advantages in workflow compared to traditional chest X-ray (CXR). To explore why, we convened focus groups to address barriers and facilitators of implementation for POCUS guided CVC confirmation and de-implementation of post-procedure CXR. METHODS: We conducted focus groups with emergency medicine and critical care providers to discuss current practices in POCUS for CVC confirmation. The semi-structured focus group interview guide was informed by the Consolidated Framework for Implementation Research (CFIR). We performed qualitative content analysis of the resulting transcripts using a consensual qualitative research approach (NVivo software), aiming to identify priority categories that describe the barriers and facilitators of POCUS guided CVC confirmation. RESULTS: The coding dictionary of barriers and facilitators consisted of 21 codes from the focus group discussions. Our qualitative analysis revealed that 12 codes emerged spontaneously (inductively) within the focus group discussions and aligned directly to CFIR constructs. Common barriers included provider influences (e.g. knowledge and beliefs about POCUS for CVC confirmation), external network (e.g. societal guidelines, ancillary staff, and consultants), and inertia (habit or reflexive processes). Common facilitators included ultrasound protocol advantage and champions. Time and provider outcomes (cognitive offload, ownership, and independence) emerged as early barriers but late facilitators. CONCLUSION: Our qualitative analysis demonstrates real and perceived barriers against implementation of POCUS for CVC position confirmation and pneumothorax exclusion. Our findings discovered organizational and personal constructs that will inform development of multifaceted strategies toward implementation of POCUS after CVC insertion.


Asunto(s)
Cateterismo Venoso Central , Catéteres Venosos Centrales , Neumotórax , Humanos , Cateterismo Venoso Central/métodos , Ultrasonografía/métodos , Investigación Cualitativa
17.
Acad Emerg Med ; 30(8): 800-808, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36775281

RESUMEN

BACKGROUND: Studies using fast-acting subcutaneous (SQ) insulin analogs in diabetic ketoacidosis (DKA) have demonstrated efficacy, safety, and cost-effectiveness, allowing treatment of mild-to-moderate (MTM)-severity DKA patients in non-intensive care unit (ICU) settings. However, emergency department (ED)-based studies are few, with limited exploration of impacts on operational metrics. METHODS: We implemented the SQuID (Subcutaneous Insulin in Diabetic Ketoacidosis) protocol for adults with MTM-severity DKA in an urban academic ED, collecting data from August 1, 2021, to February 28, 2022. We examined fidelity (frequency of required q2h glucose checks), safety (proportion of patients administered rescue dextrose for hypoglycemia), and ED length of stay (EDLOS) for the SQuID cohort compared to patients (non-ICU) treated with a traditional insulin infusion. We also examined ICU admission rate among MTM-severity DKA patients after introduction of SQuID to two historical control periods (pre-intervention and pre-COVID). We used Mann-Whitney U to test for differences in EDLOS distributions, bootstrapped (n = 1000) confidence intervals (CIs) for EDLOS median differences, and the two-sample z-test for differences in ICU admissions. RESULTS: We identified 177 MTM-severity DKA patients in the study period (78 SQuID, 99 traditional cohort) and 163 preintervention and 161 pre-COVID historical control patients. Fidelity to the SQuID pathway was good, with glucose checks exceeding the q2-h requirement. We found no difference in the proportion of rescue dextrose administration compared to the traditional pathway. We observed significant reductions in median EDLOS for the SQuID cohort compared to the traditional cohort during the study period (-3.0, 95% CI -8.5 to -1.4), the preintervention period (-1.4, 95% CI -3.1 to -0.1), and the pre-COVID control period (-3.6, 95% CI -7.5 to -1.8). CONCLUSIONS: In this single-center study at an academic ED, treatment of patients with MTM-severity DKA with a SQ insulin protocol was effective, demonstrated equivalent safety, and reduced ED length of stay.


Asunto(s)
COVID-19 , Diabetes Mellitus , Cetoacidosis Diabética , Adulto , Humanos , Insulina/uso terapéutico , Cetoacidosis Diabética/tratamiento farmacológico , Benchmarking , Glucosa , Estudios Retrospectivos
18.
Ann Emerg Med ; 59(4): 285-93, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22153971

RESUMEN

STUDY OBJECTIVE: The quality measure "Rh immunoglobulin administration for Rh-negative women at risk for fetal blood exposure" was recently endorsed by the National Quality Forum. No published data have shown a related performance gap in US emergency departments (EDs). We determine performance in a US ED for appropriate Rh testing and treatment among pregnant ED patients at risk of fetal blood exposure. METHODS: This was a retrospective, observational study in an urban, academic ED with 97,000 annual visits. We performed record review of all pregnant ED patients aged 14 to 50 years and presenting between June 1, 2009, and June 1, 2010, to determine whether a sensitizing event or a potential sensitizing event occurred and whether Rh testing and treatment with Rh immunoglobulin were performed when indicated. Performance rates were calculated under 2 different assumptions for patients without Rh testing ordered in the ED but who had previous data in the electronic medical record: (1) unless explicitly documented by the treating physician, previous Rh data were considered as not having been checked; and (2) when available in the electronic medical record, Rh status was always considered as having been checked. Interrater reliability was assessed for whether a trauma represented a sensitizing event. RESULTS: Among 1,465 patients identified, 808 met inclusion criteria; 560 had a sensitizing event and 248 had a potential sensitizing event. Interrater reliability for determination of sensitizing event or potential sensitizing event in trauma was moderate (κ=0.42). Performance rates for Rh testing among patients with sensitizing events, with potential sensitizing events, and overall were 73% (95% confidence interval [CI] 69% to 76%) (408/560), 36% (95% CI 31% to 43%) (90/248), and 62% (95% CI 58% to 65%) (498/808). Appropriate treatment for patients with a sensitizing event, with a potential sensitizing event, and overall was 56% (95% CI 39% to 71%) (19/34), 0% (95% CI 0% to 49%) (0/5), and 48% (95% CI 33% to 63%) (19/39). Assuming that physicians were aware of previous Rh results yielded performance rates of 96% (95% CI 93% to 97%) (535/560), 73% (95% CI 67% to 78%) (181/248), and 89% (95% CI 86% to 91%) (716/808) and treatment performance rates of 54% (95% CI 38% to 69%) (20/37), 0% (95% CI 0% to 30%) (0/11), and 42% (95% CI 29% to 56%) (20/48). CONCLUSION: In this single-center study, among patients with a sensitizing event, performance was moderate for Rh testing and treatment with Rh immunoglobulin. Despite lack of consensus or uncertainties in certain measure definitions, in at least 1 US academic ED there appears to be an opportunity for further evaluation and performance improvement in this area.


Asunto(s)
Servicio de Urgencia en Hospital , Complicaciones Hematológicas del Embarazo/diagnóstico , Isoinmunización Rh/diagnóstico , Globulina Inmune rho(D)/uso terapéutico , Adolescente , Adulto , Servicio de Urgencia en Hospital/organización & administración , Servicio de Urgencia en Hospital/normas , Servicio de Urgencia en Hospital/estadística & datos numéricos , Femenino , Adhesión a Directriz/estadística & datos numéricos , Humanos , Persona de Mediana Edad , Embarazo , Complicaciones Hematológicas del Embarazo/inmunología , Complicaciones Hematológicas del Embarazo/terapia , Embarazo Ectópico/diagnóstico , Estudios Retrospectivos , Isoinmunización Rh/inmunología , Isoinmunización Rh/terapia , Globulina Inmune rho(D)/inmunología , Adulto Joven
19.
Ann Emerg Med ; 60(3): 280-90.e4, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22364867

RESUMEN

STUDY OBJECTIVE: Computed tomography (CT) use has increased rapidly, raising concerns about radiation exposure and cost. The Centers for Medicare & Medicaid Services (CMS) developed an imaging efficiency measure (Outpatient Measure 15 [OP-15]) to evaluate the use of brain CT in the emergency department (ED) for atraumatic headache. We aim to determine the reliability, validity, and accuracy of OP-15. METHODS: This was a retrospective record review at 21 US EDs. We identified 769 patient visits that CMS labeled as including an inappropriate brain CT to identify clinical indications for CT and reviewed the 748 visits with available records. The primary outcome was the reliability of OP-15 as determined by CMS from administrative data compared with medical record review. Secondary outcomes were the measure's validity and accuracy. Outcome measures were defined according to the testing protocol of the American Medical Association's Physician Consortium for Performance Improvement. RESULTS: On record review, 489 of 748 ED brain CTs identified as inappropriate by CMS had a measure exclusion documented that was not identified by administrative data; the measure was 34.6% reliable (95% confidence interval [CI] 31.2% to 38.0%). Among the 259 patient visits without measure exclusions documented in the record, the measure's validity was 47.5% (95% CI 41.4% to 53.6%), according to a consensus list of indications for brain CT. Overall, 623 of the 748 ED visits had either a measure exclusion or a consensus indication for CT; the measure's accuracy was 16.7% (95% CI 14% to 19.4%). Hospital performance as reported by CMS did not correlate with the proportion of CTs with a documented clinical indication (r=-0.11; P=.63). CONCLUSION: The CMS imaging efficiency measure for brain CTs (OP-15) is not reliable, valid, or accurate and may produce misleading information about hospital ED performance.


Asunto(s)
Servicio de Urgencia en Hospital/normas , Cefalea/diagnóstico por imagen , Medicare/normas , Anciano , Encéfalo/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neuroimagen/normas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/normas , Estados Unidos
20.
J Emerg Med ; 43(4): e235-8, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20417053

RESUMEN

BACKGROUND: Porphyria variegata (VP) is one of the hepatic porphyrias that results from the deficiency of protoporphyrinogen oxidase, an enzyme in the heme synthesis pathway. The name porphyria variegata refers to its many presentations, which include various neuropsychiatric and cutaneous manifestations. Emergency department (ED) presentations due to VP are most commonly neuropathic abdominal pain. CASE REPORT: We present the case of a 57-year-old woman presenting to an ED with abdominal pain consistent with prior VP attacks. In addition to analgesics and supportive care, infusion of intravenous dextrose resulted in improvement in her symptoms. CONCLUSION: Intravenous dextrose and heme administration remain the first-line treatment for abdominal pain attributable to known acute hepatic porphyria attacks. Recently, the mechanism of action of carbohydrates in treating porphyria has been elucidated. Current information on this illness and ED management are discussed.


Asunto(s)
Dolor Abdominal/terapia , Porfiria Variegata/terapia , Dolor Abdominal/etiología , Analgésicos Opioides/uso terapéutico , Femenino , Fluidoterapia , Glucosa/uso terapéutico , Humanos , Hidromorfona/uso terapéutico , Persona de Mediana Edad , Porfiria Variegata/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA