1.
Europace ; 25(2): 748-755, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36305566

RESUMEN

AIMS: Pulsed-field ablation (PFA) is an emerging non-thermal ablation method based on the biophysical phenomenon of electroporation. Data on PFA cardiac selectivity nature and tissue-specific thresholds are lacking. We aim to compare the in vivo differential effect of high-frequency irreversible electroporation (HF-IRE) protocols on various tissues. METHODS AND RESULTS: Twenty-three Sprague-Dawle rodents were allocated into three different protocols of 300, 600, and 900 V, respectively, while delivering twenty 100 µs bursts of a 150 kHz biphasic square wave to five tissues; cardiac muscle, skeletal muscle, liver, carotid artery and sciatic nerve. Lesions were evaluated quantitatively by histologic analysis and by morphometric evaluation. There were eight, seven and eight animals in the 300, 600, and 900 V protocols, respectively. High-frequency electroporation protocols showed a graded effect on myocardial tissue with larger lesions in the 900 V protocol compared with the other two protocols as demonstrated by width (P = 0.02), length (P = 0.01) and fibrosis ratio (P = 0.001). This effect was not observed for other tissues with attenuated degree of damage. No damage to the carotid artery was observed in all protocols. Partial damage to the sciatic nerve was observed in only two samples (25%) in the 600 V group and in one sample (14.3%) in the 900 V group. CONCLUSION: Electroporation effect is tissue-specific such that myocardium is more prone to electroporation damage compared with neural and vascular tissues. Our results suggest no neural or vascular damage with using a low-amplitude HF-IRE protocol. Further investigation is warranted to better identify other tissue-specific thresholds.


Asunto(s)
Electroporación , Miocardio , Animales , Electroporación/métodos , Terapia de Electroporación , Corazón
2.
JACC Clin Electrophysiol ; 7(8): 959-964, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34217666

RESUMEN

This study compared monophasic 100-µs pulses with high-frequency electroporation (HF-EP) bursts using an in vivo animal model. Myocardial damage was evaluated by histologic analysis. Compared with 10 monophasic pulses, 20 bursts of HF-EP at 100 and 150 kHz were associated with less damage. However, when the number of HF-EP bursts was increased to 60, myocardial damage was comparable to that of the monophasic group. HF-EP protocols were associated with attenuated collateral muscle contractions. This study shows that HF-EP is feasible and effective and that pulse frequency has a significant effect on extent of ablation.


Asunto(s)
Electroporación , Corazón , Animales , Miocardio