Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Diabetes Obes Metab ; 21(7): 1596-1605, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30843339

RESUMEN

AIMS: To compare HbA1c and hypoglycaemia in insulin-naïve patients with type 2 diabetes (T2D) who initiated insulin glargine 300 units/mL (Gla-300) or 100 units/mL (Gla-100). MATERIALS AND METHODS: This retrospective cohort study examined electronic medical records of insulin-naïve adults with T2D who initiated Gla-300 or Gla-100 during March 2015 through to December 2016 with active records for ≥12 months before and ≥6 months after initiation, and ≥1 valid HbA1c value during 6-month baseline and 90-180-day follow-up. Outcomes included HbA1c and hypoglycaemia. Cohorts were propensity score-matched (1:2) on baseline demographic and clinical characteristics. Sensitivity analyses were conducted using broader inclusion criteria. RESULTS: The matched cohorts included 1004 Gla-300 and 2008 Gla-100 initiators (mean age 60.4 years; 53.2% male). During 6-month follow-up, Gla-300 versus Gla-100 initiators had a greater mean HbA1c decrease (-1.52 ± 2.08% vs. -1.30 ± 2.12%; P = 0.003) and more patients achieved HbA1c <7% (25.0% vs. 21.5%; P = 0.029) and <8% (55.0% vs. 49.2%; P = 0.002); and HbA1c <7% (21.9% vs. 17.4%; P = 0.003) and <8% (49.1% vs. 41.8%; P < 0.001) without hypoglycaemia. Gla-300 initiators were similarly or less likely to have any or inpatient/emergency department-associated hypoglycaemia during 3- and 6-month follow-up (e.g. any hypoglycaemia to 6 months: 9.7% vs. 12.5%; adjusted odds ratio 0.61; P = 0.057). CONCLUSIONS: Among insulin-naïve adults with T2D, Gla-300 was associated with significantly better HbA1c reductions (latest value during 90-180-day follow-up) and similar or improved hypoglycaemia outcomes (3- and 6-month follow-up) than Gla-100.


Asunto(s)
Diabetes Mellitus Tipo 2/tratamiento farmacológico , Hipoglucemia , Hipoglucemiantes/administración & dosificación , Insulina Glargina/administración & dosificación , Glucemia/análisis , Femenino , Hemoglobina Glucada/análisis , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemia/epidemiología , Hipoglucemiantes/efectos adversos , Hipoglucemiantes/uso terapéutico , Insulina Glargina/efectos adversos , Insulina Glargina/uso terapéutico , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
2.
Diabetes Obes Metab ; 21(9): 2123-2132, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31144445

RESUMEN

AIM: To compare glycaemic control, hypoglycaemia and treatment discontinuation of insulin glargine 300 units/mL (Gla-300) and insulin degludec (IDeg) in a real-world study of insulin-naïve adults with type 2 diabetes (T2D). MATERIALS AND METHODS: DELIVER Naive D was a retrospective observational study that used electronic medical record data from the IBM Watson Health Explorys database. Insulin-naïve adults with T2D who started Gla-300 or IDeg between March 2015 and September 2017 were identified. Patients were active in the system for ≥12 months before and ≥6 months after starting Gla-300 or IDeg and had HbA1c measurements during 6-month baseline and 3- to 6-month follow-up. Outcomes were compared among 1:1 propensity score-matched cohorts. RESULTS: In the matched cohorts (n = 638 each), the mean age was 59 years, approximately 53% were male, and mean HbA1c was 9.67% (82 mmol/mol). Mean (SD) HbA1c decreases were comparable in the Gla-300 and IDeg cohorts (-1.67% [2.22] and -1.58% [2.20]; P = 0.51), as were HbA1c target attainment [<7% (53 mmol/mol): 23.8% and 27.4%; P = 0.20; <8% (64 mmol/mol): 55.0% and 57.1%; P = 0.63] and treatment discontinuation (29.2% and 32.6%; P = 0.14). Overall and inpatient/emergency department-associated hypoglycaemia incidences and event rates were similar in both cohorts using fixed 6-month or variable on-treatment follow-up. CONCLUSIONS: Among real-world insulin-naïve adults with T2D, initiation of Gla-300 or IDeg resulted in comparable improvements in glycaemic control and similar rates of hypoglycaemia. These real-world data complement and confirm a randomized trial and other real-world studies.


Asunto(s)
Diabetes Mellitus Tipo 2/tratamiento farmacológico , Hipoglucemia/epidemiología , Hipoglucemiantes/uso terapéutico , Insulina Glargina/uso terapéutico , Insulina de Acción Prolongada/uso terapéutico , Glucemia/efectos de los fármacos , Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/complicaciones , Femenino , Hemoglobina Glucada/efectos de los fármacos , Humanos , Hipoglucemia/etiología , Incidencia , Masculino , Persona de Mediana Edad , Puntaje de Propensión , Estudios Retrospectivos , Resultado del Tratamiento
3.
Diabetes Obes Metab ; 21(11): 2384-2393, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31264346

RESUMEN

AIM: To compare the second-generation basal insulin glargine 300 units/mL (Gla-300) and first-generation basal insulins on glycaemic control and hypoglycaemia risk in older adults with type 2 diabetes (T2D). MATERIALS AND METHODS: DELIVER 3 was a retrospective observational cohort study of electronic medical records. A total of 1176 older adults (aged ≥ 65 years) with T2D and ≥1 HbA1c value during 6 month baseline and 3 to 6 month follow-up who switched from basal insulin to Gla-300 were propensity score-matched to 1176 older adults who switched to a first-generation basal insulin [insulin detemir (IDet) or insulin glargine 100 units/mL (Gla-100)]. Outcomes were follow-up HbA1c, achievement of HbA1c <7% and <8%, hypoglycaemia incidence and event rates, and healthcare resource utilization. RESULTS: Following basal insulin switching, HbA1c reductions were greater/similar with Gla-300 versus IDet/Gla-100 (variable follow-up: -0.45% ± 1.40% vs. -0.29% ± 1.57%; P = .021; fixed follow-up: -0.48% ± 1.49% vs. -0.38% ± 1.59%; P = .114), while HbA1c goal attainment was similar in both cohorts. Gla-300 was associated with less hypoglycaemia [event rate: adjusted rate ratio (aRR): 0.63, 95% CI: 0.53-0.75; P < .001] and inpatient/emergency department-associated hypoglycaemia (adjusted hazard ratio: 0.58, 95% CI: 0.37-0.90; P = .016; aRR: 0.43, 95% CI: 0.31-0.60; P < .001) by variable follow-up. By fixed follow-up, hypoglycaemia results significantly or numerically favoured Gla-300. CONCLUSION: Among older adults with T2D, switching to Gla-300 versus Gla-100/IDet was associated with greater/similar improvements in glycaemic control, and generally less hypoglycaemia.


Asunto(s)
Diabetes Mellitus Tipo 2 , Insulina Glargina/uso terapéutico , Anciano , Anciano de 80 o más Años , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/epidemiología , Femenino , Hemoglobina Glucada/análisis , Hospitalización/estadística & datos numéricos , Humanos , Hipoglucemia , Insulina Glargina/administración & dosificación , Masculino , Estudios Retrospectivos
4.
Diabetes Obes Metab ; 20(9): 2148-2158, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29938887

RESUMEN

AIMS: To compare clinical outcomes in patients with type 2 diabetes (T2D) switching from insulin glargine 100 units/mL (Gla-100) or insulin detemir (IDet) to insulin glargine 300 units/mL (Gla-300) or insulin degludec (IDeg). MATERIALS AND METHODS: We conducted a retrospective, observational study of electronic medical records for Gla-300/IDeg adult switchers (March 1, 2015 to January 31, 2017) with active records for 12-month baseline (glycated haemoglobin [HbA1c] used a 6-month baseline period) and 6-month follow-up periods. Gla-300 and IDeg switchers were propensity score-matched using baseline demographic and clinical characteristics. Outcomes were HbA1c change and goal attainment (among patients with HbA1c captured at follow-up), and hypoglycaemia with fixed follow-up (intention-to-treat [ITT]; 6 months) and variable follow-up (on-treatment [OT]; to discontinuation or 6 months). RESULTS: Each matched cohort comprised 1592 patients. The mean decrease in HbA1c and HbA1c goal (<7.0% [53 mmol/mol] and <8.0% [64 mmol/mol]) attainment rates were similar for Gla-300 (n = 742) and IDeg (n = 727) switchers. Using fixed follow-up (ITT method), hypoglycaemia incidence decreased significantly from baseline with Gla-300 (all hypoglycaemia: 15.6% to 12.7%; P = .006; hypoglycaemia associated with inpatient/emergency department [ED] encounter: 5.3% to 3.5%; P = .007), but not with IDeg. After adjusting for baseline hypoglycaemia, no significant differences in hypoglycaemia incidence and event rate were found at follow-up (ITT) for Gla-300 vs IDeg. Using variable follow-up (OT), hypoglycaemia incidence was similar in both groups, but Gla-300 switchers had a lower inpatient/ED hypoglycaemia event rate at follow-up (adjusted rate ratio 0.56; P = .016). CONCLUSIONS: In a real-world setting, switching from Gla-100 or IDet to Gla-300 or IDeg was associated with similar improvements in glycaemic control and hypoglycaemia in adult patients with T2D.


Asunto(s)
Diabetes Mellitus Tipo 2/tratamiento farmacológico , Sustitución de Medicamentos , Hipoglucemiantes/administración & dosificación , Insulina Glargina/administración & dosificación , Insulina de Acción Prolongada/administración & dosificación , Anciano , Glucemia , Investigación sobre la Eficacia Comparativa , Diabetes Mellitus Tipo 2/sangre , Femenino , Hemoglobina Glucada , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemiantes/efectos adversos , Insulina/análogos & derivados , Insulina Glargina/efectos adversos , Insulina de Acción Prolongada/efectos adversos , Masculino , Persona de Mediana Edad , Puntaje de Propensión , Estudios Retrospectivos , Resultado del Tratamiento
5.
Diabetes Obes Metab ; 20(5): 1293-1297, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29272064

RESUMEN

This retrospective cohort study compared real-world clinical and healthcare-resource utilization (HCRU) data in patients with type 2 diabetes using basal insulin (BI) who switched to insulin glargine 300 units/mL (Gla-300) or another BI. Data from the Predictive Health Intelligence Environment database 12 months before (baseline) and 6 months after (follow-up) the switch date (index date, March 1, 2015 to May 31, 2016) included glycated haemoglobin A1c (HbA1c), hypoglycaemia, HCRU and associated costs. Baseline characteristics were balanced using propensity score matching. Change in HbA1c from baseline was similar in both matched cohorts (n = 1819 in each). Hypoglycaemia incidence and adjusted event rate were significantly lower with Gla-300. Patients switching to Gla-300 had a significantly lower incidence of HCRU related to hypoglycaemia. All-cause and diabetes-related hospitalization and emergency-department HCRU were also favourable for Gla-300. Lower HCRU translated to lower costs in patients using Gla-300. In this real-world study, switching to Gla-300 reduced the risk of hypoglycaemia in patients with type 2 diabetes when compared with those switching to another BI, resulting in less HCRU and potential savings of associated costs.


Asunto(s)
Ahorro de Costo , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Costos de la Atención en Salud , Hiperglucemia/prevención & control , Hipoglucemia/prevención & control , Insulina Glargina/uso terapéutico , Estudios de Cohortes , Costos y Análisis de Costo , Prestación Integrada de Atención de Salud , Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/economía , Composición de Medicamentos , Monitoreo de Drogas/economía , Registros Electrónicos de Salud , Femenino , Estudios de Seguimiento , Hemoglobina Glucada/análisis , Humanos , Hiperglucemia/economía , Hiperglucemia/terapia , Hipoglucemia/inducido químicamente , Hipoglucemia/economía , Hipoglucemia/terapia , Insulina/efectos adversos , Insulina/economía , Insulina/uso terapéutico , Insulina Glargina/efectos adversos , Insulina Glargina/economía , Masculino , Persona de Mediana Edad , Aceptación de la Atención de Salud , Estudios Retrospectivos , Estados Unidos
6.
Endocrinol Diabetes Metab ; 5(1): e00306, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34807513

RESUMEN

AIMS: To compare 12-month clinical effectiveness of insulin glargine 300 units/mL (Gla-300) versus first-generation basal insulin analogues (BIAs) (insulin glargine 100 units/mL [Gla-100] or insulin detemir [IDet]) in patients with type 2 diabetes (T2D) who were at high risk of hypoglycaemia and switched from one BIA to a different one (Gla-300 or Gla-100/IDet) in a real-world setting. METHODS: DELIVER High Risk was a retrospective observational cohort study of 2550 patients with T2D who switched BIA to Gla-300 (Gla-300 switchers) and were propensity score-matched (1:1) to patients who switched to Gla-100 or IDet (Gla-100/IDet switchers). Outcomes were change in glycated haemoglobin A1c (HbA1c), attainment of HbA1c goals (<7% and <8%), and incidence and event rates of hypoglycaemia (all-hypoglycaemia and hypoglycaemia associated with an inpatient/emergency department [ED] contact). RESULTS: HbA1c reductions were similar following switching to Gla-300 or Gla-100/IDet (-0.51% vs. -0.53%; p = .67), and patients showed similar attainment of HbA1c goals. Patients in both cohorts had comparable all-hypoglycaemia incidence and event rates. However, the Gla-300 switcher cohort had a significantly lower risk of inpatient/ED-associated hypoglycaemia (adjusted odds ratio: 0.73, 95% confidence interval: 0.60-0.89; p = .002) and experienced significantly fewer inpatient/ED-associated hypoglycaemic events (0.21 vs. 0.33 events per patient per year; p < .001). CONCLUSION: In patients with T2D at high risk of hypoglycaemia, switching to Gla-300 or Gla-100/IDet achieved similar HbA1c reductions and glycaemic goal attainment, but Gla-300 switchers had a significantly lower risk of hypoglycaemia associated with an inpatient/ED contact during 12 months after switching.


Asunto(s)
Diabetes Mellitus Tipo 2 , Hipoglucemia , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/epidemiología , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemia/epidemiología , Insulina , Insulina Glargina/efectos adversos , Estudios Retrospectivos , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA