Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Radiol ; 33(11): 7840-7848, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37338555

RESUMEN

OBJECTIVES: To investigate the effect of a device-assisted suction against resistance Mueller maneuver (MM) on transient interruption of contrast (TIC) in the aorta and pulmonary trunk (PT) on computed tomography pulmonary angiogram (CTPA). METHODS: In this prospective single-center study, 150 patients with suspected pulmonary artery embolism were assigned randomly with two different breathing maneuvers (Mueller maneuver (MM) or standard end-inspiratory breath-hold command (SBC)) during routine CTPA. The MM was performed using a patented prototype (Contrast Booster™) which allows both the patient by means of visual feedback and the medical staff in the CT scanning room to monitor whether the patient is sucking sufficiently or not. Mean Hounsfield attenuation in descending aorta and PT was measured and compared. RESULTS: Overall, patients with MM showed an attenuation of 338.24 HU in the pulmonary trunk, compared to 313.71 HU in SBC (p = 0.157). In the aorta, the values for MM were lower compared to SBC (134.42 HU vs. 177.83 HU, p = 0.001). The TP-aortic ratio was significantly higher in the MM group at 3.86 compared to the SBC group at 2.26, p = 0.001. TIC phenomenon was absent in the MM group, whereas it was present in 9 patients (12.3%) in the SBC group (p = 0.005). Overall contrast was better on all levels for MM (p < 0.001). The presence of breathing artifacts was higher in the MM group (48.1% vs. 30.1%, p = 0.038), without clinical consequence. CONCLUSIONS: Performing the MM with the application of the prototype is an effective way of preventing the TIC phenomenon during i.v. contrast-enhanced CTPA scanning compared to the standard end-inspiratory breathing command. CLINICAL RELEVANCE: Compared to standard end-inspiratory breathing command, the device-assisted Mueller maneuver (MM) improves contrast enhancement and prevents the transient interruption of contrast (TIC) phenomenon in CTPA. Therefore, it may offer optimized diagnostic workup and timely treatment for patients with pulmonary embolism. KEY POINTS: • Transient interruption of contrast (TIC) may impair image quality in CTPA. • Mueller Maneuver using a device prototype could lower the rate of TIC. • Device application in clinical routine may increase diagnostic accuracy.


Asunto(s)
Embolia Pulmonar , Tomografía Computarizada por Rayos X , Humanos , Succión , Estudios Prospectivos , Tomografía Computarizada por Rayos X/métodos , Arteria Pulmonar/diagnóstico por imagen , Embolia Pulmonar/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Medios de Contraste
2.
AJR Am J Roentgenol ; 218(1): 132-139, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34406050

RESUMEN

BACKGROUND. Sequences with noncartesian k-space sampling may improve image quality of head and neck MRI. OBJECTIVE. The purpose of this study was to compare intraindividually the image quality of a spiral gradient-recalled echo (GRE) sequence and conventional cartesian GRE and cartesian turbo spin-echo (TSE) sequences for contrast-enhanced T1-weighted head and neck MRI. METHODS. This prospective study included patients referred for contrast-enhanced head and neck MRI from August 2020 to May 2021. Patients underwent 1.5-T MRI including contrast-enhanced spiral GRE (2 minutes 28 seconds), cartesian GRE (4 minutes 27 seconds), and cartesian TSE (3 minutes 41 seconds) sequences, acquired in rotating order across patients. Three radiologists independently assessed image quality measures, including conspicuity of prespecified lesions, using 5-point Likert scales. One reader measured maximal extent of dental material artifact and contrast-to-noise ratio (CNR). RESULTS. Thirty-one patients (13 men, 18 women; mean age, 63.8 years) were enrolled. Nineteen patients had a focal lesion; 22 had dental material. Interreader agreement for image quality measures was substantial to excellent (Krippendorff alpha, 0.681-1.000). Scores for overall image quality (whole head and neck, neck only, and head only), pulsation artifact, muscular contour delineation, vessel contour delineation, motion artifact, and differentiation between mucosa and pharyngeal muscles were significantly better for spiral GRE than for cartesian GRE and cartesian TSE for all readers (p < .05). Scores for lesion conspicuity (whole head and neck, neck only, and head only), quality of fat suppression, flow artifact, and foldover artifact were not significantly different between spiral GRE and the cartesian sequences for any reader (p > .05). Dental material artifact scores were significantly worse for spiral GRE than the other sequences for all readers (p < .05). The mean maximum extent of dental material artifact was 39.6 ± 25.5 (SD) mm for spiral GRE, 35.6 ± 24.3 mm for cartesian GRE, and 29.6 ± 21.4 mm for cartesian TSE; the mean CNR was 221.1 ± 94.5 for spiral GRE, 151.8 ± 85.7 for cartesian GRE, and 153.0 ± 63.2 for cartesian TSE (p < .001 between spiral GRE and other sequences for both measures). CONCLUSION. Three-dimensional spiral GRE improves subjective image quality and CNR of head and neck MRI with shorter scan time versus cartesian sequences, though it exhibits larger dental material artifact. CLINICAL IMPACT. A spiral sequence may help overcome certain challenges of conventional cartesian sequences for head and neck MRI.


Asunto(s)
Medios de Contraste , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Femenino , Cabeza/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Cuello/diagnóstico por imagen , Estudios Prospectivos , Reproducibilidad de los Resultados
3.
Eur Radiol ; 31(4): 2126-2131, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33021703

RESUMEN

Faced with the COVID-19 pandemic, many countries both in Europe and across the world implemented strict stay-at-home orders. These measures helped to slow the spread of the coronavirus but also led to increased mental and physical health issues for the domestically confined population, including an increase in the occurrence of intimate partner violence (IPV) in many countries. IPV is defined as behavior that inflicts physical, psychological, or sexual harm within an intimate relationship. We believe that as radiologists, we can make a difference by being cognizant of this condition, raising an alert when appropriate and treating suspected victims with care and empathy. The aim of this Special Report is to raise awareness of IPV among radiologists and to suggest strategies by which to identify and support IPV victims. KEY POINTS: • The COVID-19 pandemic led to a marked increase in the number of intimate partner violence (IPV) cases, potentially leading to increased emergency department visits and radiological examinations. • Most IPV-related fractures affect the face, fingers, and upper trunk, and may easily be misinterpreted as routine trauma. • Radiologists should carefully review the medical history of suspicious cases, discuss the suspicion with the referring physician, and proactively engage in a private conversation with the patient, pointing to actionable resources for IPV victims.


Asunto(s)
COVID-19 , Violencia de Pareja , Europa (Continente) , Humanos , Pandemias/prevención & control , Radiólogos , SARS-CoV-2
4.
Eur Radiol ; 31(11): 8725-8732, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33909134

RESUMEN

OBJECTIVES: We investigate in what percentage of cases and to what extent radiological reports change when radiologists directly communicate with patients after imaging examinations. METHODS: One hundred twenty-two consecutive outpatients undergoing MRI examinations at a single center were prospectively included. Radiological reports of the patients were drafted by two radiologists in consensus using only the clinical information that was made available by the referring physicians. Thereafter, one radiologist talked directly with the patient and recorded the duration of the conversation. Afterwards, the additional information from the patient was used to reevaluate the imaging studies in consensus. The radiologists determined whether the radiological report changed based on additional information and, if yes, to what extent. The degree of change was graded on a 4-point Likert scale (1, non-relevant findings, to 4, highly relevant findings). RESULTS: Following direct communication (duration 170.9 ± 53.9 s), the radiological reports of 52 patients (42.6%) were changed. Of the 52 patients, the degree of change was classified as grade 1 for 8 patients (15.4 %), grade 2 for 27 patients (51.9%), grade 3 for 13 patients (25%), and grade 4 for 4 patients (7.7%). The reasons leading to changes were missing clinical information in 50 cases (96.2%) and the lack of additional external imaging in 2 cases (3.8%). CONCLUSIONS: Radiologists should be aware that a lack of accurate information from the clinician can lead to incorrect radiological reports or diagnosis. Radiologists should communicate directly with patients, especially when the provided information is unclear, as it may significantly alter the radiological report. KEY POINTS: • Direct communication between radiologists and patients for an average of 170's resulted in a change in the radiological reports of 52 patients (42.6%). • Of the 42.6% of cases where the reports were changed, the alterations were highly relevant (grades 3 and 4) in 32.7%, indicating major changes with significant impact towards patient management.


Asunto(s)
Radiólogos , Radiología , Comunicación , Humanos , Imagen por Resonancia Magnética , Radiografía
5.
Eur Radiol ; 30(12): 6933-6936, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32607631

RESUMEN

KEY POINTS: • The COVID-19 crisis resulted in a variety of physical and mental health issues beyond the viral infection itself, as indicated by an increase in domestic violence.• Radiologists should be aware of typical intimate partner violence (IPV) injury patterns, actively ask potential IPV victims about the cause of injury, and be familiar with support systems for IPV victims of their institutions.• Emergency and radiology departments should review their protocols for identifying and supporting IPV victims, and train their staff to work together to implement these measures during and beyond the COVID-19 crisis.


Asunto(s)
Infecciones por Coronavirus/diagnóstico , Servicio de Urgencia en Hospital , Violencia de Pareja/psicología , Pandemias , Neumonía Viral/diagnóstico , Radiólogos , Betacoronavirus , COVID-19 , Infecciones por Coronavirus/psicología , Femenino , Humanos , Masculino , Neumonía Viral/psicología , SARS-CoV-2
6.
Eur Radiol ; 29(11): 5813-5822, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31020338

RESUMEN

PURPOSE: To identify independent confounding variables of gadoxetate-enhanced hepatobiliary-phase liver MRI using multiple regression analysis. MATERIALS AND METHODS: The institutional review board generally approved retrospective analyses and all patients provided written informed consent. One hundred ten patients who underwent a standardized 3.0-T gadoxetate-enhanced liver MRI between November 2008 and June 2013 were retrospectively reviewed. The gadoxetate liver enhancement normalized to enhancement in the erector spinae muscle (relative signal enhancement, SE) was related to biochemical laboratory parameters and descriptive patient characteristics (patient age, body mass index) using non-parametric univariate correlation analysis followed by a multiple linear regression model. RESULTS: Using univariate statistics, relative SE was inversely correlated with patient age, ALP, AST, total bilirubin, gamma-glutamyltransferase, INR, model of end-stage liver disease score, and proportionally with albumin and hemoglobin (all p < 0.01). In a multiple regression analysis, total bilirubin (p = 0.001), serum albumin (p = 0.016), and patient age (p = 0.018) were independently correlated with relative liver SE (n = 110). CONCLUSION: A multiple regression analysis showed that high total bilirubin, low serum albumin, or advanced age was associated with low hepatobiliary-phase gadoxetate parenchymal liver enhancement. In these patients, the lower contrast-to-noise ratio might impair diagnostic evaluation of non-enhancing liver lesions (e.g., HCC, liver metastasis). KEY POINTS: • A multiple regression analysis identified independent confounding variables of hepatobiliary-phase gadoxetate liver enhancement. • High bilirubin, low albumin, or advanced age was associated with low enhancement. • Diagnostic evaluation might be hampered in these patients.


Asunto(s)
Bilirrubina/metabolismo , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/patología , Albúmina Sérica/metabolismo , Adulto , Anciano , Biomarcadores de Tumor/metabolismo , Medios de Contraste , Femenino , Gadolinio DTPA , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , gamma-Glutamiltransferasa/metabolismo
7.
Eur Radiol ; 29(1): 224-231, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29943178

RESUMEN

OBJECTIVES: To investigate patients' perception of the radiology service when the radiologist communicates the findings to patients. METHODS: After routine MRI, patients in group 1 (n = 101) were given the opportunity to discuss the findings with the radiologist. Patients in group 2 (n = 101) left the radiology department without any personal communication. Subsequently, by means of a questionnaire designed by an expert psychologist, both groups were asked regarding their anxiety, emotional attachment to the institute and subjective assessment of competence. RESULTS: Overall 76 % of all patients were concerned about their imaging findings without significant difference between both groups (p = 0.179). Significantly more patients in group 1 (81%) versus group 2 (14%; p < 0.001) perceived the opportunity to discuss their imaging findings with a radiologist to be a characteristic of a good radiology consultation. A larger number of patients in group 1 experienced significantly higher bonding and only wanted in the future to be examined in the department with communication (p = 0.001) (93%/75%). Significantly more patients in group 1 regarded the radiology department they attended as being more competent (mean score 4.72/4.09, p < 0.001). CONCLUSION: Direct communication of imaging findings from radiologists to patients after an MRI examination leads to increased confidence in the radiology service and higher bonding between the patient and radiologist. Radiologists who refrain from direct communication have a lower bonding to patients and are assessed to have lower competence from the patient's point of view. KEY POINTS: • Communication between radiologists and patients leads to an increased bonding affinity. • Direct communication leads to increased patient confidence in the radiology service. • Patients perceived discussion with a radiologist of high value.


Asunto(s)
Comunicación , Imagen por Resonancia Magnética/psicología , Relaciones Médico-Paciente , Radiólogos/psicología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Ansiedad/etiología , Actitud Frente a la Salud , Competencia Clínica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Atención al Paciente , Derivación y Consulta , Encuestas y Cuestionarios , Revelación de la Verdad , Adulto Joven
8.
Eur Radiol ; 29(2): 527-534, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30062526

RESUMEN

OBJECTIVES: To determine whether it would be hygienic to evaluate dogs and humans in the same MRI scanner. METHODS: We compared the bacterial load in colony-forming units (CFU) of human-pathogenic microorganisms in specimens taken from 18 men and 30 dogs. In addition, we compared the extent of bacterial contamination of an MRI scanner shared by dogs and humans with two other MRI scanners used exclusively by humans. RESULTS: Our study shows a significantly higher bacterial load in specimens taken from men's beards compared with dogs' fur (p = 0.036). All of the men (18/18) showed high microbial counts, whereas only 23/30 dogs had high microbial counts and 7 dogs moderate microbial counts. Furthermore, human-pathogenic microorganisms were more frequently found in human beards (7/18) than in dog fur (4/30), although this difference did not reach statistical significance (p = 0.074). More microbes were found in human oral cavities than in dog oral cavities (p < 0.001). After MRI of dogs, routine scanner disinfection was undertaken and the CFU found in specimens isolated from the MRI scanning table and receiver coils showed significantly lower bacteria count compared with "human" MRI scanners (p < 0.05). CONCLUSION: Our study shows that bearded men harbour significantly higher burden of microbes and more human-pathogenic strains than dogs. As the MRI scanner used for both dogs and humans was routinely cleaned after animal scanning, there was substantially lower bacterial load compared with scanners used exclusively for humans. KEY POINTS: • Bearded men harbour significantly more microbes than dogs. • Dogs are no risk to humans if they use the same MRI. • Deficits in hospital hygiene are a relevant risk for patients.


Asunto(s)
Perros/microbiología , Cabello/microbiología , Higiene , Imagen por Resonancia Magnética/instrumentación , Pelaje de Animal/microbiología , Animales , Bacterias/aislamiento & purificación , Carga Bacteriana , Recuento de Colonia Microbiana , Infección Hospitalaria/prevención & control , Infección Hospitalaria/transmisión , Desinfección , Contaminación de Equipos/prevención & control , Humanos , Masculino
12.
Eur Radiol ; 27(10): 4181-4187, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28374081

RESUMEN

OBJECTIVES: Aim was to investigate hygienic conditions of ultrasound probes before and after hygiene training in radiology institutions in comparison to bacterial contamination in public places. METHODS: In three radiology departments, bacterial contamination was evaluated using baseline agar plates for cultures taken from 36 ultrasound probes. Afterwards teams were trained by a hygiene service centre and 36 ultrasound probes were routinely disinfected with regular disinfecting wipes and then evaluated. In comparison, bacterial contamination in public places (bus poles, n = 11; toilet seats, n = 10) were analysed. Plates were routinely incubated and the number of colony forming units (CFU) analysed. RESULTS: Cultures taken from the probes showed a median of 53 CFU before and 0 CFU after training (p < 0.001). Cultures taken from public places showed a median of 4 CFU from toilets and 28 from bus poles and had lower bacterial load in comparison to ultrasound probes before training (p = 0.055, toilets; p = 0.772, bus poles), without statistical significance. CONCLUSIONS: Bacterial contamination of ultrasound probes prior to hygiene training proved to be high and showed higher bacterial load than toilets seats or bus poles. Radiologists should be aware that the lack of hygiene in the field of ultrasound diagnostics puts patients at risk of healthcare-associated infections. KEY POINTS: • Hospital-associated infections are a problem for patient care. • Hygiene training of staff prevents bacterial contamination of ultrasound probes. • Disinfection of ultrasound probes is an easy method to protect patients.


Asunto(s)
Bacterias/aislamiento & purificación , Desinfectantes/uso terapéutico , Desinfección/normas , Contaminación de Equipos/prevención & control , Higiene/educación , Transductores/microbiología , Ultrasonografía/instrumentación , Recuento de Colonia Microbiana , Infección Hospitalaria/prevención & control , Humanos
13.
J Magn Reson Imaging ; 43(6): 1407-16, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26587694

RESUMEN

PURPOSE: To evaluate serial apparent diffusion coefficient (ADC) measurements of bone metastases in prostate cancer to determine whether antiandrogen resistance can be detected and time to progression estimated. MATERIALS AND METHODS: Diffusion-weighted imaging (DWI) was performed at 1.5T in nine patients with treatment-naïve metastatic prostate cancer (20 lesions) before antiandrogen treatment, after 1, 2, and 3 months of treatment, and thereafter every 4 months over 31 months or until antiandrogen resistance was detected. Tumor volumes were stable over time. Time courses of the ADCs when averaged over entire lesions and on functional diffusion maps (fDMs) were analyzed using marginal linear model (MLM) analysis. RESULTS: Starting at 1 month, MLM analysis revealed decreasing mean ADCs (P = 0.001) over time. Simultaneously, the percentage of voxels with significantly higher ADCs decreased (P = 0.004), whereas the percentage of voxels with significantly lower ADCs increased (P < 0.001) on fDMs. Both mean ADCs (P = 0.042) and percentages of voxels with significantly higher ADCs on fDMs (P = 0.039) decreased more rapidly over time in patients with a shorter progression-free interval (PFI). Likewise, higher (P = 0.001) and more rapidly increasing (P = 0.002) percentages of voxels with significantly lower ADCs on fDMs were associated with a shorter PFI. CONCLUSION: The results of our pilot study suggest that the evolution of ADCs over time may permit early identification of antiandrogen resistance in bone metastases. J. Magn. Reson. Imaging 2016;43:1407-1416.


Asunto(s)
Antagonistas de Andrógenos/administración & dosificación , Neoplasias Óseas/tratamiento farmacológico , Neoplasias Óseas/secundario , Imagen de Difusión por Resonancia Magnética/métodos , Monitoreo de Drogas/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/tratamiento farmacológico , Anciano , Anciano de 80 o más Años , Antineoplásicos/administración & dosificación , Neoplasias Óseas/patología , Resistencia a Antineoplásicos , Humanos , Masculino , Proyectos Piloto , Pronóstico , Neoplasias de la Próstata/patología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
14.
Eur Radiol ; 26(6): 1889-94, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26334505

RESUMEN

OBJECTIVES: To identify correlations of signal enhancements (SE) and SE normalized to reference tissues of the spleen, kidney, liver, musculus erector spinae (MES) and ductus hepatocholedochus (DHC) on hepatobiliary phase gadoxetate-enhanced MRI with patient age in non-cirrhotic patients. METHODS: A heterogeneous cohort of 131 patients with different clinical backgrounds underwent a standardized 3.0-T gadoxetate-enhanced liver MRI between November 2008 and June 2013. After exclusion of cirrhotic patients, a cohort of 75 patients with no diagnosed diffuse liver disease was selected. The ratio of signal intensity 20 min post- to pre-contrast administration (SE) in the spleen, kidney, liver, MES and DHC, and the SE of the kidney, liver and DHC normalized to the reference tissues spleen or MES were compared to patient age. RESULTS: Patient age was inversely correlated with the liver SE normalized to the spleen and MES SE (both p < 0.001) and proportionally with the SE of the spleen (p = 0.043), the MES (p = 0.030) and the kidney (p = 0.022). No significant correlations were observed for the DHC (p = 0.347) and liver SE (p = 0.606). CONCLUSION: The age dependence of hepatic SE normalized to the enhancement in the spleen and MES calls for a cautious interpretation of these quantification methods. KEY POINTS: • Patient age was inversely correlated with spleen- and MES-corrected liver rSE (p < 0.001). • Patient age was correlated with spleen (p = 0.043) and MES SE (p = 0.030). • Patient age may confound quantitative liver function assessment using gadoxetate-enhanced liver MRI.


Asunto(s)
Gadolinio DTPA/farmacología , Aumento de la Imagen/métodos , Hepatopatías/diagnóstico , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Músculos/diagnóstico por imagen , Bazo/diagnóstico por imagen , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Medios de Contraste/farmacología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
15.
Eur Radiol ; 26(8): 2705-13, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26515548

RESUMEN

OBJECTIVES: This study was conducted in order to compare a high resolution, non-contrast-enhanced MRA (NATIVE SPACE, NE-MRA) of the pedal vasculature with contrast-enhanced MRA (CE-MRA) and digital subtraction angiography (DSA) in patients with peripheral arterial occlusive disease (PAOD). METHODS: The prospective study consists of 20 PAOD patients. All patients underwent percutaneous transluminal angioplasty or stenting and received MR angiographies the following day. RESULTS: With CE-MRA, 75.7 % of vessel segments showed good, 16.4 % suboptimal and 7.9 % not usable image quality. With NE-MRA, 64.6 % showed good, 18.6 % suboptimal and 16.8 % not usable image quality. CE-MRA showed a sensitivity and negative predictive value of 90 %/95 % regarding significant stenosis (greater than 50 %), and specificity and positive predictive value were 88 %/77 %. Accordingly, sensitivity and negative predictive value for the NE-MRA were 96 %/97 % and specificity and positive predictive value were 80 %/69 % for stenoses greater than 50 %. CONCLUSIONS: The applied NE-MRA technique achieves high diagnostic accuracy even in very small distal arteries of the foot. However, the rate of non-diagnostic vessel segments is considerably higher for NE-MRA than for CE-MRA. NE-MRA is a valuable alternative to CE-MRA in selected patients. KEY POINTS: • Comparison of non-enhanced MRA with contrast-enhanced MRA and DSA as gold standard. • High resolution MRA at 3 T for the depiction of small pedal vessels. • Evaluation of high resolution non-enhanced MRA in PAOD patients.


Asunto(s)
Angiografía de Substracción Digital/métodos , Arteriopatías Oclusivas/diagnóstico , Arterias/diagnóstico por imagen , Electrocardiografía/métodos , Pie/irrigación sanguínea , Angiografía por Resonancia Magnética/métodos , Adulto , Anciano , Arteriopatías Oclusivas/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Venas/diagnóstico por imagen
16.
Eur Radiol ; 26(8): 2714-22, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26573682

RESUMEN

OBJECTIVE: To investigate whether a trained group of technicians using a modified breathing command during gadoxetate-enhanced liver MRI reduces respiratory motion artefacts compared to non-trained technicians using a traditional breathing command. MATERIALS AND METHODS: The gadoxetate-enhanced liver MR images of 30 patients acquired using the traditional breathing command and the subsequent 30 patients after training the technicians to use a modified breathing command were analyzed. A subgroup of patients (n = 8) underwent scans both by trained and untrained technicians. Images obtained using the traditional and modified breathing command were compared for the presence of breathing artefacts [respiratory artefact-based image quality scores from 1 (best) to 5 (non-diagnostic)]. RESULTS: There was a highly significant improvement in the arterial phase image quality scores in patients using the modified breathing command compared to the traditional one (P < 0.001). The percentage of patients with severe and extensive breathing artefacts in the arterial phase decreased from 33.3 % to 6.7 % after introducing the modified breathing command (P = 0.021). In the subgroup that underwent MRI using both breathing commands, arterial phase image quality improved significantly (P = 0.008) using the modified breathing command. CONCLUSION: Training technicians to use a modified breathing command significantly improved arterial phase image quality of gadoxetate-enhanced liver MRI. KEY POINTS: • A modified breathing command reduced respiratory artefacts on arterial-phase gadoxetate-enhanced MRI (P < 0.001). • The modified command decreased severe and extensive arterial-phase breathing artefacts (P = 0.021). • Training technicians to use a modified breathing command improved arterial-phase images.


Asunto(s)
Artefactos , Gadolinio DTPA/farmacología , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Respiración , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste/farmacología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Movimiento (Física)
18.
Eur Radiol ; 25(11): 3133-42, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26032878

RESUMEN

OBJECTIVE: Our aim was to prospectively investigate whether the recently introduced suction/inspiration against resistance breathing method leads to higher computed tomography (CT) contrast density in the pulmonary artery compared to standard breathing. MATERIAL AND METHODS: The present study was approved by the Medical Ethics committee and all subjects gave written informed consent. Fifteen patients, each without suspicious lung emboli, were randomly assigned to four different groups with different breathing maneuvers (suction against resistance, Valsalva, inspiration, expiration) during routine CT. Contrast enhancement in the central and peripheral sections of the pulmonary artery were measured and compared with one another. RESULTS: Peripheral enhancement during suction yielded increased mean densities of 138.14 Hounsfield units (HU) (p = 0.001), compared to Valsalva and a mean density of 67.97 HU superior to inspiration (p = 0.075). Finally, suction in comparison to expiration resulted in a mean increase of 30.51 HU (p = 0.42). Central parts of pulmonary arteries presented significantly increased enhancement values (95.74 HU) for suction versus the Valsalva technique (p = 0.020), while all other mean densities were in favour of suction (versus inspiration: p = 0.201; versus expiration: p = 0.790) without reaching significance. CONCLUSION: Suction/Inspiration against resistance is a promising technique to improve contrast density within pulmonary vessels, especially in the peripheral parts, in comparison to other breathing maneuvers. KEY POINTS: • Suction/Inspiration against resistance is promising to improve contrast density within the pulmonary artery. • Patients potentially suffering pulmonary embolism are able to follow suction/inspiration against resistance. • Contrast density after suction is superior in comparison to other breathing maneuvers.


Asunto(s)
Medios de Contraste/administración & dosificación , Arteria Pulmonar/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Tomografía Computarizada por Rayos X/métodos , Administración Intravenosa , Adulto , Anciano , Espiración/fisiología , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Inhalación/fisiología , Yohexol/administración & dosificación , Yohexol/análogos & derivados , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Sistemas de Información Radiológica , Succión , Maniobra de Valsalva
19.
Radiology ; 273(2): 452-61, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24869795

RESUMEN

PURPOSE: To compare revised Choi criteria that incorporate concurrent size and attenuation changes at early follow-up imaging with Response Evaluation Criteria in Solid Tumors ( RECIST Response Evaluation Criteria in Solid Tumors ) 1.1 and original Choi criteria in stratification of clinical outcomes in patients with metastatic renal cell carcinoma ( mRCC metastatic renal cell carcinoma ) treated with sunitinib. MATERIALS AND METHODS: Institutional review board approved this retrospective study and waived informed consent. Baseline and first follow-up computed tomographic scans in 69 patients (50 men, 19 women; mean age, 60.3 years; range, 19-83 years) with mRCC metastatic renal cell carcinoma treated with sunitinib from October 1, 2008, to March 1, 2013, were evaluated for tumor response by using RECIST Response Evaluation Criteria in Solid Tumors 1.1, original Choi criteria, and revised Choi criteria. Correlations with overall survival ( OS overall survival ) and progression-free survival ( PFS progression-free survival ) were compared and stratified according to each radiologic criteria with Kaplan-Meier and multivariate Cox regression analysis. RESULTS: Median follow-up time was 29.7 months (95% confidence interval [ CI confidence interval ]: 18.9, 45.9). Response according to revised Choi criteria was independently correlated with OS overall survival (hazard ratio, 0.47 [95% CI confidence interval : 0.23, 0.99]; P = .046) and PFS progression-free survival (hazard ratio, 0.53 [95% CI confidence interval : 0.29, 0.99]; P = .047). Response according to RECIST Response Evaluation Criteria in Solid Tumors was not significantly correlated with OS overall survival (hazard ratio, 0.65 [95% CI confidence interval : 0.27, 1.58]; P = .344) or PFS progression-free survival (hazard ratio, 0.89 [95% CI confidence interval : 0.42, 1.91]; P = .768). Response according to original Choi criteria was not significantly correlated with OS overall survival (hazard ratio, 0.60 [95% CI confidence interval : 0.32, 1.11]; P = .106) or PFS progression-free survival (hazard ratio, 0.59 [95% CI confidence interval : 0.34, 1.02]; P = .060). Median OS overall survival and PFS progression-free survival in responders according to revised Choi criteria was 39.4 months (95% CI confidence interval : 9.1, upper limit not estimated) and 13.7 months (95% CI confidence interval : 6.4, 24.6), respectively, compared with 12.8 months (95% CI confidence interval : 8.7, 18.0) and 5.3 months (95% CI confidence interval : 3.9, 8.4), respectively, in nonresponders. CONCLUSION: Contemporaneous reduction in tumor size and attenuation were correlated with favorable clinical outcomes. Response according to revised Choi criteria showed better correlation with clinical outcomes compared with that according to RECIST Response Evaluation Criteria in Solid Tumors or original Choi criteria in patients with mRCC metastatic renal cell carcinoma treated with sunitinib.


Asunto(s)
Inhibidores de la Angiogénesis/uso terapéutico , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/tratamiento farmacológico , Indoles/uso terapéutico , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/tratamiento farmacológico , Pirroles/uso terapéutico , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Humanos , Yohexol , Masculino , Persona de Mediana Edad , Criterios de Evaluación de Respuesta en Tumores Sólidos , Estudios Retrospectivos , Sunitinib , Tasa de Supervivencia , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
20.
Eur Radiol ; 24(12): 3034-41, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25103533

RESUMEN

OBJECTIVES: Optimal contrast within the pulmonary artery is achieved by the maximum amount of contrast-enhanced blood flowing through the superior vena cava (SVC), while minimum amounts of non-contrasted blood should originate from the inferior vena cava (IVC). This study aims to clarify whether "suction against resistance" might optimise this ratio. METHODS: Phase-contrast pulse sequences on a 1.5T MRI magnet were used for flow quantification (mean flow (mL/s), stroke volume (Vol) in the SVC and IVC in volunteers. Different breathing manoeuvers were analysed repeatedly: free breathing; inspiration; expiration; suction against resistance, and Valsalva. To standardise breathing commands, volunteers performed suction and Valsalva manoeuvers with an MR-compatible manometer. RESULTS: Suction against resistance was associated with a significant drop of the IVC/SVC flow quotient (1.63 [range 1.3-2.0] p < 0.05 at -10 mmHg and 1.48 [1.1-1.9] p < 0.01 at -20 mmHg) corresponding to increased blood flow from SVC and diminished flow originating from the IVC. The remaining breathing commands (free breathing 2.2; inspiration 2.4; expiration 2.4; Valsalva 10 mmHg 2.3; Valsalva 20 mmHg 2.6; and Valsalva 30 mmHg 2.2) showed no differences (p > 0.05). CONCLUSIONS: Suction against resistance caused a significant drop in the IVC/SVC quotient. Theoretically, this breathing manoeuver might significantly improve the enhancement characteristics of CT angiography. KEY POINTS: Suction provokes reduction in blood flow in the inferior vena cava. Ratio between the inferior and superior vena cava blood flow diminished during suction. Manometer used during breathing standardises MR phase-contrast blood flow measurements.


Asunto(s)
Respiración , Vena Cava Inferior/fisiología , Vena Cava Superior/fisiología , Adulto , Análisis de Varianza , Velocidad del Flujo Sanguíneo/fisiología , Femenino , Humanos , Angiografía por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Arteria Pulmonar/fisiología , Volumen Sistólico/fisiología , Succión , Maniobra de Valsalva/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA