Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Lasers Surg Med ; 52(7): 653-658, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-31755127

RESUMEN

BACKGROUND/OBJECTIVES: Standard optical coherence tomography angiography (OCTA) has been limited to imaging blood vessels actively undergoing perfusion, providing a temporary picture of surface microvasculature. Capillary perfusion in the skin is dynamic and changes in response to the surrounding tissue's respiratory, nutritional, and thermoregulatory needs. Hence, OCTA often represents a given perfusion state without depicting the actual extent of the vascular network. Here we present a method for obtaining a more accurate anatomic representation of the surface capillary network in human skin using OCTA, along with proposing a new parameter, the Relative Capillary Capacity (RCC), a quantifiable proxy for assessing capillary dilation potential and permeability. METHODS: OCTA images were captured at baseline and after compression of the skin. Baseline images display ambient capillary perfusion, while images taken upon capillary refill display the network of existing capillaries at full capacity. An optimization-based automated vessel segmentation method was used to automatically analyze and compare OCTA image sequences obtained from two volunteers. RCC was then compared with visual impressions of capillary viability. RESULTS: Our OCTA imaging sequence provides a method for mapping cutaneous capillary networks independent of ambient perfusion. Differences between baseline and refill images clearly demonstrate the shortcomings of standard OCTA imaging and produce the RCC biometric as a quantifiable proxy for assessing capillary dilation potential and permeability. CONCLUSION: Future dermatological OCTA diagnostic studies should implement the Capillary Refill Methods over standard imaging techniques and further explore the relevance of RCC to differential diagnosis and dermatopathology. Lasers Surg. Med. © The Authors. Lasers in Surgery and Medicine published by Wiley Periodicals, Inc.


Asunto(s)
Capilares , Tomografía de Coherencia Óptica , Capilares/diagnóstico por imagen , Angiografía con Fluoresceína , Humanos , Microvasos/diagnóstico por imagen , Piel/diagnóstico por imagen
2.
Klin Monbl Augenheilkd ; 233(12): 1324-1330, 2016 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-27984838

RESUMEN

Optical coherence tomography (OCT) uses interference to image the retina with high axial resolution. In the last 25 years, new technologies have permitted a steady increase in imaging speed, which made it possible to enlarge the imaged field and to avoid motion artefacts. The speed and precision of retinal imaging is now limited by photodamage of the retina caused by the focused OCT beam and by the speed of the scanning mechanics. Full-field swept-source (FF-SS)-OCT decreases irradiance on the retina and dispenses moving parts by using a camera to acquire the full volume of the retina in parallel. Here we show that FF-SS-OCT is rapid and precise enough to image pulsation in the retina induced by the heart beat. Series of OCT volumes 1.8 × 0.7 mm wide and 1.8 mm deep were recorded in young volunteers over a few cycles of the heart beat. Morphology of the retinal vessels, blood flow and tissue motion as caused by vessel pulsation were calculated from the OCT data. FF-SS-OCT was able to visualise the main structures of the neuronal retina, including vessels and small capillaries and without any motion artefacts. Information on three different dynamic processes was obtained from only one recorded series of OCT volumes: pulsation of blood flow and blood pressure in retinal vessels as well as pulsation of the choroid. Delays between arterial and venous pulse and delay between pulsation in retinal and choroidal vessels were calculated. With a time resolution of 0.5 ms, FF-SS-OCT is able to visualise previously unmeasurably fast changes in the retina, including the propagation of pulse waves.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Presión Sanguínea/fisiología , Interpretación de Imagen Asistida por Computador/métodos , Flujo Pulsátil/fisiología , Vasos Retinianos/fisiología , Tomografía de Coherencia Óptica/métodos , Angiografía/métodos , Técnicas de Diagnóstico Oftalmológico , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
3.
Eur Arch Otorhinolaryngol ; 272(11): 3217-23, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25384576

RESUMEN

A microscope-based optical coherence tomography (OCT) device was used to assess the microanatomy of the tympanic membrane in patients with chronic myringitis. A prospective study was designed for this purpose. OCT measurements of the tympanic membrane were done on 11 patients with myringitis with a microscope-based spectral domain OCT system. The in vivo findings were compared with those findings of a control group consisting of 36 patients with retraction pockets or atrophic tympanic membranes (n = 13), myringosclerosis (n = 12) and perforations (n = 11). In active chronic myringitis, the thickness of the tympanic membrane is increased compared to healthy membranes and to other pathological conditions of the tympanic membrane. Consistent changes of the microanatomy of the tympanic membrane were found in chronic myringitis with OCT. Serial OCT measurements revealed no biofilm suspicious findings in all patients with active chronic myringitis. Intraoperative and in vivo OCT measurements may help to detect microanatomical changes of the tympanic membrane in chronic myringitis and in other conditions of the tympanic membrane.


Asunto(s)
Otitis/patología , Tomografía de Coherencia Óptica , Membrana Timpánica/patología , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
6.
Dev Ophthalmol ; 45: 40-48, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20502025

RESUMEN

The conjunctiva, as a peripheral mucosal surface, is dependent on the migration of immune cells to facilitate an orchestrated immune response. So far, only limited data to visualize these dynamics directly have been obtained, mainly due to technical and experimental restrictions. To investigate migration on a cellular level, the following conditions need to be met: (1) intravital investigations need to be facilitated by suitable microscopic techniques; (2) tissues need to be investigated in three spatial dimensions and over time; (3) data need to contain detailed information about the tissue character. Whereas the use of confocal laser scanning microscopy allows high-resolution imaging of the superficial conjunctival immune system and enables the recording of rapid cellular migration, intravital two-photon microscopy further enables tracking of individual cells and characterization of cells and structures with unique optical features using autofluorescence detection, fluorescence lifetime measurements and second harmonic generation in deep tissue. Based on current results and experimental studies, two-photon microscopy has the potential for general use in basic research and clinical practice, and would greatly enhance possibilities for diagnosing and analyzing inflammatory processes of the ocular surface. In particular, inflammation in common diseases, such as allergy and dry eye, and its progress under treatment could be investigated in detail.


Asunto(s)
Conjuntiva/citología , Sistema Inmunológico/citología , Microscopía Confocal , Microscopía de Fluorescencia por Excitación Multifotónica , Animales , Sistemas de Computación , Humanos , Procesamiento de Imagen Asistido por Computador
7.
Acta Neurochir (Wien) ; 151(5): 507-17; discussion 517, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19343270

RESUMEN

INTRODUCTION: Intraoperative detection of residual tumor remains an important challenge in surgery to treat gliomas. New developments in optical techniques offer non-invasive high-resolution imaging that may integrate well into the workflow of neurosurgical operations. Using an intracranial glioma model, we have recently shown that time domain optical coherence tomography (OCT) allows discrimination of normal brain, diffusely invaded brain tissue, and solid tumor. OCT imaging allowed acquisition of 2D and 3D data arrays for multiplanar analysis of the tumor to brain interface. In this study we have analyzed biopsy specimens of human brain tumors and we present the first feasibility study of intraoperative OCT and post-image acquisition processing for non-invasive imaging of the brain and brain tumor. METHODS: We used a Sirius 713 Tomograph with a superluminescence diode emitting light at a near infrared central wavelength of 1,310 nm and a coherence length of 15 microm. The light is passed through an optical mono mode fiber to a modified OCT adapter containing a lens system with a working distance of 10 cm and an integrated pilot laser. Navigation-registered tumor biopsies were imaged ex vivo and the intraoperative site of optical tissue analysis was registered by marker acquisition using a neuronavigation system. RESULTS: Optical coherence tomography non-contact measurements of brain and brain tumor tissue produced B-scan images of 4 mm in width and 1.5-2.0 mm in depth at an axial and lateral optical resolution of 15 microm. OCT imaging demonstrated a different microstructure and characteristic signal attenuation profiles of tumor versus normal brain. Post-image acquisition processing and automated detection of the tissue to air interface was used to realign A-scans to compensate for image distortions caused by pulse- and respiration-induced movements of the target volume. Realigned images allowed monitoring of intensity changes within the scan line and facilitated selection of areas for the averaging of A-scans and the calculation of attenuation coefficients for specific regions of interest. CONCLUSION: This feasibility study has demonstrated that OCT analysis of the tissue microstructure and light attenuation characteristics discriminate normal brain, areas of tumor infiltrated brain, solid tumor, and necrosis. The working distance of the OCT adapter and the A-scan acquisition rate conceptually allows integration of the OCT applicator into the optical path of the operating microscopes. This would allow a continuous analysis of the resection plain, providing optical tomography, thereby adding a third dimension to the microscopic view and information on the light attenuation characteristics of the tissue.


Asunto(s)
Neoplasias Encefálicas/diagnóstico , Glioma/diagnóstico , Tomografía de Coherencia Óptica/métodos , Biopsia , Neoplasias Encefálicas/patología , Neoplasias Encefálicas/cirugía , Estudios de Factibilidad , Glioma/patología , Glioma/cirugía , Humanos , Técnicas In Vitro , Monitoreo Intraoperatorio/métodos , Proyectos Piloto
8.
Klin Monbl Augenheilkd ; 226(12): 958-64, 2009 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-20108189

RESUMEN

BACKGROUND: Optical coherence tomography (OCT) is new diagnostic procedure that has rapidly evolved in the last years. The recently developed spectral domain OCT allows one to increase the imaging speed by a hundred times compared to the first generation time domain OCT and enables three-dimensional imaging as well as real-time imaging of fast moving structures. Volumetric imaging improves the quantitative measurement of morphology and the evaluation of temporal changes. In addition, an exact correlation with images acquired with other imaging modalities is possible. Real-time imaging enables also the use of OCT during examinations with the slit-lamp and during ophthalmological surgery. METHODS: A spectral domain OCT was adapted to a slit lamp. 70 patients (91 eyes) were examined at the anterior or posterior segment of the eye. Images of healthy structures and different pathologies were compared to OCT images obtained with Stratus 3, Spectralis, and the SL-OCT. To demonstrate the feasibility of OCT during surgery, spectral domain OCT devices working with 20,000 and 210,000 A scans per second were coupled by specially developed optics to the camera port of a surgical microscope. The device was tested with phantoms and enucleated pig eyes. RESULTS AND CONCLUSIONS: A 5 kHz spectral domain OCT can image the retina during slit lamp-based indirect ophthalmoscopy with a quality similar to that of the Stratus 3. In addition, relevant structures of the anterior segment were imaged. Here, compared to commercially available devices, the imaged field was smaller and the angle of the anterior chamber was not directly visible due to the 830 nm wavelength, which had to be used for retinal imaging. Through the surgical microscope, a volumetric imaging of epithelium, Bowman's, Descemet's membranes, limbus, iris, lens, conjunctiva and sclera was demonstrated with several tens of centimetre working distance. Instruments and incisions in the cornea were visualised with 20 microm precision. Real-time imaging and visualisation of volumetric OCT data were also demonstrated. In principle, all technical problems of an intraoperative use of OCT have been solved and a clinical trial will start in the near future. OCT has the potential to improve the precision of surgical interventions and may even enable new interventions.


Asunto(s)
Enfermedades de la Retina/patología , Enfermedades de la Retina/cirugía , Retinoscopía/métodos , Cirugía Asistida por Computador/métodos , Tomografía de Coherencia Óptica/métodos , Humanos , Retinoscopía/tendencias , Cirugía Asistida por Computador/tendencias , Tomografía de Coherencia Óptica/tendencias
9.
HNO ; 57(5): 421-7, 2009 May.
Artículo en Alemán | MEDLINE | ID: mdl-19384537

RESUMEN

The application of optical coherence tomography (OCT) in middle ear surgery has a high diagnostic potential, especially for intraoperative evaluation of the cause of stapes fixation, intraoperative assessment of the morphology of the stapes footplate in revision stapes surgery, and as an orientation guide in cochlear implantation in congenital anomalies. OCT displays the middle and inner ear structures precisely. This technology enables the surgeon to use this information for further specification of the intraoperative modus operandi. Considering our own in vivo and ex vivo investigations and animal experiments, potential areas of application can be defined: visualization of the oval window niche in revision stapesplasty and reconstructive middle ear surgery, as well as during explorative tympanotomy for intraoperative assessment of perilymph fistula, and demonstration of structures of the exposed but not opened inner ear.


Asunto(s)
Cóclea/anatomía & histología , Cóclea/cirugía , Cirugía del Estribo/tendencias , Cirugía Asistida por Computador/tendencias , Tomografía de Coherencia Óptica/tendencias , Animales , Humanos , Cirugía del Estribo/métodos , Cirugía Asistida por Computador/métodos , Tomografía de Coherencia Óptica/métodos
10.
Int J Comput Assist Radiol Surg ; 14(2): 301-309, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30056592

RESUMEN

PURPOSE: Retinal vein cannulation is an experimental procedure during which a clot-dissolving drug is injected into an obstructed retinal vein. However, due to the fragility and minute size of retinal veins, such procedure is considered too risky to perform manually. With the aid of surgical robots, key limiting factors such as: unwanted eye rotations, hand tremor and instrument immobilization can be tackled. However, local instrument anatomy distance and force estimation remain unresolved issues. A reliable, real-time local interaction estimation between instrument tip and the retina could be a solution. This paper reports on the development of a combined force and distance sensing cannulation needle, and its experimental validation during in vivo animal trials. METHODS: Two prototypes are reported, relying on force and distance measurements based on FBG and OCT A-scan fibres, respectively. Both instruments provide an 80 [Formula: see text] needle tip and have outer shaft diameters of 0.6 and 2.3 mm, respectively. RESULTS: Both prototypes were characterized and experimentally validated ex vivo. Then, paired with a previously developed surgical robot, in vivo experimental validation was performed. The first prototype successfully demonstrated the feasibility of using a combined force and distance sensing instrument in an in vivo setting. CONCLUSION: The results demonstrate the feasibility of deploying a combined sensing instrument in an in vivo setting. The performed study provides a foundation for further work on real-time local modelling of the surgical scene. This paper provides initial insights; however, additional processing remains necessary.


Asunto(s)
Cateterismo/instrumentación , Micromanipulación/instrumentación , Oclusión de la Vena Retiniana/cirugía , Procedimientos Quirúrgicos Robotizados/instrumentación , Animales , Cateterismo/métodos , Humanos , Modelos Animales , Agujas , Vena Retiniana , Porcinos , Tomografía de Coherencia Óptica/métodos
11.
Cell Prolif ; 40(3): 422-30, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17531085

RESUMEN

OBJECTIVES: Expression of the nuclear Ki-67 protein (pKi-67) is strongly associated with cell proliferation. For this reason, antibodies against this protein are widely used as prognostic tools for the assessment of cell proliferation in biopsies from cancer patients. Despite this broad application in histopathology, functional evidence for the physiological role of pKi-67 is still missing. Recently, we proposed a function of pKi-67 in the early steps of ribosomal RNA (rRNA) synthesis. Here, we have examined the involvement of pKi-67 in this process by photochemical inhibition using chromophore-assisted light inactivation (CALI). MATERIALS AND METHODS: Anti-pKi-67 antibodies were labelled with the fluorochrome fluorescein 5(6)-isothiocyanate and were irradiated after binding to their target protein. RESULTS: Performing CALI in vitro on cell lysates led to specific cross-linking of pKi-67. Moreover, the upstream binding factor (UBF) necessary for rRNA transcription was also partly subjected to cross-link formation, indicating a close spatial proximity of UBF and pKi-67. CALI in living cells, using micro-injected antibody, caused a striking relocalization of UBF from foci within the nucleoli to spots located at the nucleolar rim or within the nucleoplasm. pKi-67-CALI resulted in dramatic inhibition of RNA polymerase I-dependent nucleolar rRNA synthesis, whereas RNA polymerase II-dependent nucleoplasmic RNA synthesis remained almost unaltered. CONCLUSIONS: Our data presented here argue for a crucial role of pKi-67 in RNA polymerase I-dependent nucleolar rRNA synthesis.


Asunto(s)
Antígeno Ki-67/genética , Antígeno Ki-67/metabolismo , ARN Ribosómico/biosíntesis , Anticuerpos Antinucleares , Anticuerpos Monoclonales , División Celular/fisiología , Nucléolo Celular/fisiología , Fluoresceína-5-Isotiocianato , Colorantes Fluorescentes , Células HeLa , Humanos , Fotoquímica , ARN Polimerasa I/metabolismo
12.
Curr Eye Res ; 32(2): 171-6, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17364750

RESUMEN

PURPOSE: The aim of this pilot study was to evaluate whether contact optical coherence tomography (OCT) allows visualization of the effects of cyclophotocoagulation. METHODS: In this pilot study, transscleral contact OCT images (1310-nm wavelength) were generated prior to and immediately after conventional transscleral diode laser cyclophotocoagulation in three eyes of three patients who were suffering from uncontrolled glaucoma. RESULTS: In the region of the ciliary body, transscleral contact OCT revealed two layers: (i) a superficial thick hyperreflective complex representing conjunctiva, the Tenon capsule, episclera, and sclera; and (ii) a thinner hyporeflective layer representing the ciliary body. The ciliary body could be differentiated from the overlying sclera by its marked drop in reflectivity. After cyclophotocoagulation, a marked increase of reflectivity in the treated area of the ciliary body was identifiable. After treatment, the distinct border between the hyperreflective scleral complex disappeared, and the region of the ciliary body appeared hyperreflective. The optical properties of the overlying sclera remained unchanged. On corresponding averaged A-scan images, scleral thickness appeared to be slightly increased, whereas ciliary body thickness remained unchanged. CONCLUSIONS: This pilot study demonstrates the capability of contact OCT for allowing visualization of changes in the ciliary body after transscleral cyclophotocoagulation (TSCPC). Further investigations are planned to clarify the complete significance of these data.


Asunto(s)
Cuerpo Ciliar/patología , Cuerpo Ciliar/cirugía , Coagulación con Láser , Tomografía de Coherencia Óptica , Glaucoma/cirugía , Humanos , Proyectos Piloto
13.
J Photochem Photobiol B ; 34(2-3): 143-8, 1996 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-8810532

RESUMEN

Aqueous solutions of 5-aminolevulinic acid (ALA) prepared for intravesical instillation in the framework of a clinical study on the fluorescence diagnosis of urothelial bladder cancer were found to be unstable. This chemical instability of ALA was studied in aqueous solution of 37 degrees C as a function of concentration, pH and reaction time. Our investigations showed that the reaction of ALA is an irreversible process, which yields at least two reaction products in the pH range studied (pH lower than 8): the 2,5-(beta-carboxyethyl)dihydropyrazine and the 2,5-(beta-carboxyethyl)pyrazine. As a result of these studies, the conditions for the preparation of ALA solutions to be used for intravesical instillation were optimized: solution of ALA in phosphate-buffered saline at a concentration of 0.18 M (3 g of ALA in 100 ml) neutralized to pH 5, were prepared and stored on ice until use. Solutions prepared under these conditions were stable and were used for fluorescence diagnosis of bladder tumours with successful results. The effect of the pH and the composition of the urine on the extent of the reaction of ALA and on the nature of its reaction products formed during instillation was investigated by comparing the urine of patients before and immediately after instillation of ALA.


Asunto(s)
Ácido Aminolevulínico/química , Neoplasias de la Vejiga Urinaria/diagnóstico , Ácido Aminolevulínico/metabolismo , Humanos , Soluciones , Espectrofotometría Ultravioleta , Vejiga Urinaria/metabolismo
14.
Ophthalmologe ; 91(6): 824-9, 1994 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-7849439

RESUMEN

Delta-aminolevulinic acid (ALA) induced Protoporphyring IX photodynamic therapy (PDT) is a new method in the therapy of cutaneous malignancies. Topical application prevents photosensibilization of normal skin. Promising results in the treatment of superficial basal cell carcinomas have been reported. To evaluate the efficiency of this method in the therapy of basal cell carcinomas of the lid, 10 patients were treated by PDT 5 h after application of ALA. The lesions were irradiated by an argon-ion-laser-pumped dye laser at a wavelength of 630 or 635 nm and at cumulative radiant exposures of 50 and 100 J/cm2. After 5-8 weeks follow-up, the basal cell carcinomas were excised to assess histologic changes. In the first few days after PDT the lesions seemed clinically to regress, due to erythematous swelling, but after a few weeks all tumours showed the same configuration they had before irradiation. Histological examination revealed small areas of necrotic cells in all irradiated basal cell carcinomas, surrounded by residual tumour formations. The reason for the poor results may be limited penetration of ALA or light. Although ALA-induced Protoporphyrin-IX PDT is a promising approach in the therapy of dermal lesions, it is not yet an acceptable alternative method in the treatment of basal cell carcinomas of the lid.


Asunto(s)
Ácido Aminolevulínico/administración & dosificación , Carcinoma Basocelular/tratamiento farmacológico , Neoplasias de los Párpados/tratamiento farmacológico , Fotorradiación con Hematoporfirina , Administración Tópica , Anciano , Biopsia , Carcinoma Basocelular/patología , Neoplasias de los Párpados/patología , Párpados/efectos de los fármacos , Párpados/patología , Femenino , Humanos , Masculino
15.
Oftalmologia ; 38(1): 4-16, 1994.
Artículo en Ro | MEDLINE | ID: mdl-8155619

RESUMEN

Important diagnosis methods are anamnesis, visual acuity determination, visual field determination, anterior segment biomicroscopy, tonometry, gonioscopy. Great attention must be paid to the ophthalmoscopy with scleral indentation. The paper compare the advantages and disadvantages of direct ophthalmoscopy using Goldmann contact lens. A great importance has the graphical representation of the eye fundus pathology, and also applying Lincoff rules in the localisation of the retinal breaks in retinal detachment. As special methods in examination are revealed the diaphanoscopy, the angiofluorography, the computerized tomography, the tomography in magnetic resonance field, and also the utilization of the electrophysiological and echographic exams in retinal detachment diagnosis.


Asunto(s)
Desprendimiento de Retina/diagnóstico , Enfermedad Aguda , Diagnóstico Diferencial , Humanos , Métodos , Perforaciones de la Retina/diagnóstico
16.
Methods Inf Med ; 53(4): 245-9, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24992968

RESUMEN

OBJECTIVES: Optical Coherence Tomography (OCT) has been proposed as a high resolution image modality to guide transbronchial biopsies. In this study we address the question, whether individual A-scans obtained in needle direction can contribute to the identification of pulmonary nodules. METHODS: OCT A-scans from freshly resected human lung tissue specimen were recorded through a customized needle with an embedded optical fiber. Bidirectional Long Short Term Memory networks (BLSTMs) were trained on randomly distributed training and test sets of the acquired A-scans. Patient specific training and different pre-processing steps were evaluated. RESULTS: Classification rates from 67.5% up to 76% were archived for different training scenarios. Sensitivity and specificity were highest for a patient specific training with 0.87 and 0.85. Low pass filtering decreased the accuracy from 73.2% on a reference distribution to 62.2% for higher cutoff frequencies and to 56% for lower cutoff frequencies. CONCLUSION: The results indicate that a grey value based classification is feasible and may provide additional information for diagnosis and navigation. Furthermore, the experiments show patient specific signal properties and indicate that the lower and upper parts of the frequency spectrum contribute to the classification.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Biopsia Guiada por Imagen , Pulmón/patología , Redes Neurales de la Computación , Tomografía de Coherencia Óptica , Biopsia con Aguja , Humanos , Nódulos Pulmonares Múltiples/clasificación , Nódulos Pulmonares Múltiples/patología , Sensibilidad y Especificidad , Programas Informáticos
17.
J Laryngol Otol ; 123(6): 603-8, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19138456

RESUMEN

OBJECTIVE: Optical coherence tomography was used to study the stapes footplate, both in cadaveric temporal bones and during middle-ear surgery. MATERIALS AND METHODS: Optical coherence tomography was conducted on five temporal bone preparations (from two children and three adults) and in eight patients during middle-ear surgery. A specially equipped operating microscope with integrated spectral domain optical coherence tomography apparatus was used for standard middle-ear surgical procedures. RESULTS: This optical coherence tomography investigation enabled in vivo visualisation and documentation of the annular ligament, the different layers of the footplate and the inner-ear structures, both in non-fixed and fixed stapes footplates. In cases of otosclerosis and tympanosclerosis, an inhomogeneous and irregularly thickened footplate was found, in contrast to the appearance of non-fixed footplates. In both fixed and non-fixed footplates, there was a lack of visualisation of the border between the footplate and the otic capsule. CONCLUSIONS: Investigation of the relatively new technology of optical coherence tomography indicated that this imaging modality may assist the ear surgeon to assess the oval window niche intra-operatively.


Asunto(s)
Enfermedades del Oído/diagnóstico , Interpretación de Imagen Asistida por Computador/instrumentación , Ventana Oval/patología , Tomografía de Coherencia Óptica/instrumentación , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Humanos , Periodo Intraoperatorio , Persona de Mediana Edad , Otosclerosis/patología , Otosclerosis/cirugía , Ventana Oval/cirugía , Estribo , Hueso Temporal/patología , Adulto Joven
18.
J Laryngol Otol ; 123(9): 1027-30, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19243643

RESUMEN

OBJECTIVE: To introduce the use of optical coherence tomography with an operating microscope for intra-operative evaluation of the human larynx. METHODS: A specially equipped operating microscope with integrated spectral domain optical coherence tomography apparatus was used during microlaryngoscopy. RESULTS: Technical improvements in optical coherence tomography equipment (e.g. pilot beam, variable focal distance, improved image quality and integration into an operating microscope) have enabled greater sensitivity and imaging speed and a non-contact approach. Spectral domain optical coherence tomography now enables a better correlation between optical coherence tomography images and histological findings. With this new technology, the precision of biopsy can be improved during microlaryngoscopy. CONCLUSIONS: Use of this new optical coherence tomography technology, integrated into an operating microscope, enables the surgeon to define the biopsy site location and resection plane precisely, while the optical zoom of the operating microscope can be used over the complete range.


Asunto(s)
Laringe/patología , Microscopía/instrumentación , Tomografía de Coherencia Óptica/instrumentación , Humanos , Neoplasias Laríngeas/patología , Laringoscopía/métodos , Microscopía/métodos , Tomografía de Coherencia Óptica/métodos
19.
Laryngorhinootologie ; 88(3): 168-73, 2009 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-18759215

RESUMEN

BACKGROUND: CT and MRI of the windows of the temporal bone have become an important tool in the analysis of malformation, trauma and chronic otitis media. Optical Coherence-Tomography (OCT) provides optical cross-sections of the tissue, comparable to ultrasound. In a study on temporal bone specimens and during middle ear surgery we tested, whether OCT provides information about the oval window niche. MATERIAL AND METHODS: OCT was performed ex vivo on five human temporal bone preparations, in which the oval window niche was exposed and in vivo in eight patients who underwent middle ear surgery. A new OCT device, which based on spectrally resolved detection of the interference signals, was used. This OCT technology was fully integrated into an operating microscope. For direct correlation between OCT-scans and histology, three temporal bones were used. RESULTS: On all ex and in-vivo scans OCT supplies information about morphology of the stapes footplate. This OCT investigation documents the possibility to visualize in vivo annular ligament, different layers of the FP and inner ear structures. CONCLUSIONS: Intra-operative OCT application will help to visualize FP anomalies. Our study provides morphological information of the FP that may help in stapes surgery of the patients concerned.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/instrumentación , Imagenología Tridimensional/instrumentación , Periodo Intraoperatorio , Microcirugia/instrumentación , Otitis Media/cirugía , Otosclerosis/cirugía , Ventana Oval/cirugía , Cirugía del Estribo/instrumentación , Tomografía de Coherencia Óptica/instrumentación , Timpanoplastia/instrumentación , Humanos , Prótesis Osicular , Otitis Media/patología , Otosclerosis/patología , Ventana Oval/patología , Sensibilidad y Especificidad , Hueso Temporal/patología , Hueso Temporal/cirugía
20.
Laryngorhinootologie ; 87(9): 641-6, 2008 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-18421645

RESUMEN

BACKGROUND: Optical Coherence Tomography (OCT) is a relatively new imaging technique, which provides scans similar to sonography on an optical base. We questioned whether OCT may be helpful in optimizing anatomical orientation in cochlear implant (CI) surgery. In a study on temporal bone specimens we tested, whether OCT provides information about the cochlear topography, particularly in situations, when for cochleostomy the bony otic capsule is already opened but the membranous endosteal layer is still intact. MATERIAL AND METHODS: OCT was performed on five human temporal bone preparations, in which the cochleostomy was carried out still leaving the endosteum covering the fluid-filled inner ear intact. A prototype of operating microscope was used, in which a spectral-domain OCT (SD-OCT) with a central wavelength of 840 nm was integrated. RESULTS: On all scans, OCT supplies information about inner ear structures, such as the lateral attachment of the basilar membrane dividing the scalae. Even delicate structures like the Reissner's membrane could be identified in one case. CONCLUSIONS: This pilot study clearly documents the possibility to identify inner ear structures, especially the site of the scala tympani while its enveloping membranes are still intact. These findings may have an impact on cochlear implant surgery, especially as an orientation guide to localize the scala tympani precisely before opening the fluid-filled inner ear.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Audición , Rampa Timpánica , Tomografía de Coherencia Óptica , Implantación Coclear/instrumentación , Implantación Coclear/métodos , Técnicas Histológicas , Humanos , Proyectos Piloto , Rampa Timpánica/anatomía & histología , Hueso Temporal/anatomía & histología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA