1.
Sensors (Basel) ; 19(11)2019 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-31146358

RESUMEN

While modern low-power microcontrollers are a cornerstone of wearable physiological sensors, their limited on-chip storage typically makes peripheral storage devices a requirement for long-term physiological sensing-significantly increasing both size and power consumption. Here, a wearable biosensor system capable of long-term recording of physiological signals using a single, 64 kB microcontroller to minimize sensor size and improve energy performance is described. Electrodermal (EDA) signals were sampled and compressed using a multiresolution wavelet transformation to achieve long-term storage within the limited memory of a 16-bit microcontroller. The distortion of the compressed signal and errors in extracting common EDA features is evaluated across 253 independent EDA signals acquired from human volunteers. At a compression ratio (CR) of 23.3×, the root mean square error (RMSErr) is below 0.016 µ S and the percent root-mean-square difference (PRD) is below 1%. Tonic EDA features are preserved at a CR = 23.3× while phasic EDA features are more prone to reconstruction errors at CRs > 8.8×. This compression method is shown to be competitive with other compressive sensing-based approaches for EDA measurement while enabling on-board access to raw EDA data and efficient signal reconstructions. The system and compression method provided improves the functionality of low-resource microcontrollers by limiting the need for external memory devices and wireless connectivity to advance the miniaturization of wearable biosensors for mobile applications.


Asunto(s)
Técnicas Biosensibles , Respuesta Galvánica de la Piel , Diseño de Prótesis , Dispositivos Electrónicos Vestibles , Algoritmos , Compresión de Datos , Humanos , Procesamiento de Señales Asistido por Computador , Análisis de Ondículas
2.
Ann Biomed Eng ; 2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38796669

RESUMEN

This study aimed to develop and validate a Computed Tomography (CT)/Magnetic Resonance Imaging (MRI)-compatible polymer oral retractor system to enable intraoperative image guidance for transoral robotic surgery (TORS). The retractor was designed based on standard-of-care metallic retractors and 3D (three-dimensional) printed with carbon fiber composite and nylon. The system was comprehensively evaluated in bench-top and cadaveric experiments in terms of its ability to enable intraoperative CT/MR images during TORS, functionality including surgical exposure and working volume, usability, compatibility with da Vinci surgical systems, feasibility for disinfection or sterilization, and robustness over an extended period of time. The polymer retractor system enabled the acquisition of high-resolution and artifact-free intraoperative CT/MR images during TORS. With an inter-incisive distance of 42.55 mm and a working volume of 200.09 cm3, it provided surgical exposure comparable to standard-of-care metallic retractors. The system proved intuitive and compatible with da Vinci S, Xi, and Single Port systems, enabling successful mock surgical tasks performed by surgeons and residents. The retractor components could be effectively disinfected or sterilized for clinical use without significant compromise in material strength, with STERRAD considered the optimal method. Throughout a 2 h mock procedure, the retractor system showed minimal displacements (<1.5 mm) due to surrounding tissue deformation, with insignificant device deformation. The 3D-printed polymer retractor system successfully enabled artifact-free intraoperative CT/MR imaging in TORS for the first time and demonstrated feasibility for clinical use. This breakthrough opens the door to surgical navigation with intraoperative image guidance in TORS, offering the potential to significantly improve surgical outcomes and patients' quality of life.

3.
IEEE Trans Biomed Eng ; 71(1): 97-105, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37440379

RESUMEN

OBJECTIVE: This study explores the feasibility of coupling Electrical Impedance Tomography (EIT) to a standard-of-care laparoscopic surgical stapler, stapler+EIT, with the long-term goal of enabling intraoperative tissue differentiation for tumor margin detection. METHODS: Two custom printed-circuit-board-based electrode arrays with 60 and 8 electrodes, respectively, matching the stapler geometry, served as the jaws of an electrode-integrated surrogate stapler+EIT device. The device was evaluated through a series of simulations and bench-top imaging experiments of agar-gel phantoms and bovine tissue samples to evaluate the technique and determine optimal imaging parameters. RESULTS: Electrodes localized to only one jaw (the 60-electrode side) of the stapler outperformed a dual-jaw distribution of electrodes. Using this one-sided electrode array, reconstructions achieved an Area-Under-the-Curve (AUC) ≥ 0.94 for inclusions with conductivity contrasts of ≥30% for any size considered on measured agar-gel tests, and an AUC of 0.80 for bovine tissue samples. CONCLUSION: A stapler+EIT algorithm has been tuned and evaluated on challenging phantom tests and demonstrated to produce accurate reconstructions. SIGNIFICANCE: This work is an important step in the development of a surgical stapler+EIT technique for margin assessment.


Asunto(s)
Engrapadoras Quirúrgicas , Tomografía , Animales , Bovinos , Tomografía/métodos , Impedancia Eléctrica , Agar , Tomografía Computarizada por Rayos X , Electrodos
4.
IEEE Trans Biomed Eng ; PP2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38833388

RESUMEN

OBJECTIVE: A novel small form factor circular electrode array was designed specifically for electrical impedance tomography (EIT) based assessment of surgical margins during robot assisted radical prostatectomy (RARP). METHODS: The electrode array consists of 33 gold-plated electrodes arranged within a 9.5 mm diameter circular footprint on the end of a surgical probe that can be introduced through a standard 12 mm laparoscopic port used during RARP. The electrode array contains 8 larger, low-contact impedance outer electrodes dedicated for current drive and an internal grid of 25 smaller electrodes for simultaneous voltage measurement. Separating electrode geometry by function is designed to improve current delivery, speed, and resolution while reducing hardware requirements. RESULTS: Simulations demonstrated that 1 mm diameter hemispherical prostate cancer inclusions could be localized within regions of adipose and benign prostate tissue; 1.5 mm diameter inclusions were required for localization within muscle tissue. A 2.38 mm diameter aluminum rod in 0.2 S/m saline could be localized throughout the imaging domain with a position error of less than 2.5 mm for depths from the electrode array surface of up to 1.7 mm. Ex vivo tissue experiments with a bovine model demonstrate visual congruence of muscle and adipose tissue locations between the sample and reconstructed images. CONCLUSION: Simulation and experimental results indicate good detection and location of inclusions. SIGNIFICANCE: These results suggest the proposed electrode array design can provide sufficient accuracy in the detection and localization of prostate cancer against clinically relevant background tissues for use during RARP.

5.
Physiol Meas ; 45(2)2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38320323

RESUMEN

Objective.The objective of this study was to describe and evaluate a smart-phone based method to rapidly generate subject-specific finite element method (FEM) meshes. More accurate FEM meshes should lead to more accurate thoracic electrical impedance tomography (EIT) images.Approach.The method was evaluated on an iPhone®that utilized an app called Heges, to obtain 3D scans (colored, surface triangulations), a custom belt, and custom open-source software developed to produce the subject-specific meshes. The approach was quantitatively validated via mannequin and volunteer tests using an infrared tracker as the gold standard, and qualitatively assessed in a series of tidal-breathing EIT images recorded from 9 subjects.Main results.The subject-specific meshes can be generated in as little as 6.3 min, which requires on average 3.4 min of user interaction. The mannequin tests yielded high levels of precision and accuracy at 3.2 ± 0.4 mm and 4.0 ± 0.3 mm root mean square error (RMSE), respectively. Errors on volunteers were only slightly larger (5.2 ± 2.1 mm RMSE precision and 7.7 ± 2.9 mm RMSE accuracy), illustrating the practical RMSE of the method.Significance.Easy-to-generate, subject-specific meshes could be utilized in the thoracic EIT community, potentially reducing geometric-based artifacts and improving the clinical utility of EIT.


Asunto(s)
Programas Informáticos , Tomografía , Humanos , Impedancia Eléctrica , Tomografía/métodos
6.
Artículo en Inglés | MEDLINE | ID: mdl-38193213

RESUMEN

Throat tumour margin control remains difficult due to the tight, enclosed space of the oral and throat regions and the tissue deformation resulting from placement of retractors and scopes during surgery. Intraoperative imaging can help with better localization but is hindered by non-image-compatible surgical instruments, cost, and unavailability. We propose a novel method of using instrument tracking and FEM-multibody modelling to simulate soft tissue deformation in the intraoperative setting, without requiring intraoperative imaging, to improve surgical guidance accuracy. We report our first empirical study, based on four trials of a cadaveric head specimen with full neck anatomy, yields a mean TLE of 10.8 ± 5.5 mm, demonstrating methodological feasibility.

7.
Sci Rep ; 14(1): 8719, 2024 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-38622207

RESUMEN

Occult hemorrhages after trauma can be present insidiously, and if not detected early enough can result in patient death. This study evaluated a hemorrhage model on 18 human subjects, comparing the performance of traditional vital signs to multiple off-the-shelf non-invasive biomarkers. A validated lower body negative pressure (LBNP) model was used to induce progression towards hypovolemic cardiovascular instability. Traditional vital signs included mean arterial pressure (MAP), electrocardiography (ECG), plethysmography (Pleth), and the test systems utilized electrical impedance via commercial electrical impedance tomography (EIT) and multifrequency electrical impedance spectroscopy (EIS) devices. Absolute and relative metrics were used to evaluate the performance in addition to machine learning-based modeling. Relative EIT-based metrics measured on the thorax outperformed vital sign metrics (MAP, ECG, and Pleth) achieving an area-under-the-curve (AUC) of 0.99 (CI 0.95-1.00, 100% sensitivity, 87.5% specificity) at the smallest LBNP change (0-15 mmHg). The best vital sign metric (MAP) at this LBNP change yielded an AUC of 0.6 (CI 0.38-0.79, 100% sensitivity, 25% specificity). Out-of-sample predictive performance from machine learning models were strong, especially when combining signals from multiple technologies simultaneously. EIT, alone or in machine learning-based combination, appears promising as a technology for early detection of progression toward hemodynamic instability.


Asunto(s)
Sistema Cardiovascular , Hipovolemia , Humanos , Hipovolemia/diagnóstico , Presión Negativa de la Región Corporal Inferior , Signos Vitales , Biomarcadores
8.
Anesth Analg ; 117(4): 866-875, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23842194

RESUMEN

BACKGROUND: Electrical impedance tomography (EIT) is a method that can render continuous graphical cross-sectional images of the brain's electrical properties. Because these properties can be altered by variations in water content, shifts in sodium concentration, bleeding, and mass deformation, EIT has promise as a sensitive instrument for head injury monitoring to improve early recognition of deterioration and to observe the benefits of therapeutic intervention. This study presents a swine model of head injury used to determine the detection capabilities of an inexpensive bedside EIT monitoring system with a novel intracranial pressure (ICP)/EIT electrode combination sensor on induced intraparenchymal mass effect, intraparenchymal hemorrhage, and cessation of brain blood flow. Conductivity difference images are shown in conjunction with ICP data, confirming the effects. METHODS: Eight domestic piglets (3-4 weeks of age, mean 10 kg), under general anesthesia, were subjected to 4 injuries: induced intraparenchymal mass effect using an inflated, and later, deflated 0.15-mL Fogarty catheter; hemorrhage by intraparenchymal injection of 1-mL arterial blood; and ischemia/infarction by euthanasia. EIT and ICP data were recorded 10 minutes before inducing the injury until 10 minutes after injury. Continuous EIT and ICP monitoring were facilitated by a ring of circumferentially disposed cranial Ag/AgCl electrodes and 1 intraparenchymal ICP/EIT sensor electrode combination. Data were recorded at 100 Hz. Two-dimensional tomographic conductivity difference (Δσ) images, rendered using data before and after an injury, were displayed in real time on an axial circular mesh. Regions of interest (ROI) within the images were automatically selected as the upper or lower 5% of conductivity data depending on the nature of the injury. Mean Δσ within the ROIs and background were statistically analyzed. ROI Δσ was compared with the background Δσ after an injury event using an unpaired, unequal variance t test. Conductivity change within an ROI after injury was likewise compared with the same ROI before the injury making use of unpaired t tests with unequal variance. RESULTS: Eight animal subjects were studied, each undergoing 4 injury events including euthanasia. Changes in conductivity due to injury showed expected pathophysiologic effects in an ROI identified within the middle of the left hemisphere; this localization is reasonable given the actual site of injury (left hemisphere) and spatial warping associated with estimating a 3-dimensional conductivity distribution in 2-dimensional space. Results are shown as mean ± 1 SD. When averaged across all 8 animals, balloon inflation caused the mean Δσ within the ROI to shift by -11.4 ± 10.9 mS/m; balloon deflation by +9.4 ± 8.8 mS/m; blood injection by +19.5 ± 11.5 mS/m; death by -12.6 ± 13.2 mS/m. All induced injuries were detectable to statistical significance (P < 0.0001). CONCLUSION: This study confirms that the bedside EIT system with ICP/EIT combination sensor can detect induced trauma. Such a technique may hold promise for further research in the monitoring and management of traumatically brain-injured individuals.


Asunto(s)
Traumatismos Craneocerebrales/diagnóstico por imagen , Traumatismos Craneocerebrales/fisiopatología , Modelos Animales de Enfermedad , Tomografía Computarizada por Rayos X/métodos , Animales , Impedancia Eléctrica , Electrodos , Presión Intracraneal/fisiología , Monitoreo Fisiológico , Porcinos
9.
Artículo en Inglés | MEDLINE | ID: mdl-38083704

RESUMEN

Radical prostatectomy (RP) is a common surgical therapy to treat prostate cancer. The procedure has a high positive surgical margin (PSM) rate ranging from 4-48%. Patients with PSMs have a higher rate of cancer recurrence and often undergo noxious adjuvant therapy. Intraoperative surgical margin assessment (SMA) with an electrical impedance-based probe can potentially identify PSMs in real-time. This would enable surgeons to make data-based decisions in the operating room to improve patient outcomes. This paper focuses on characterizing an impedance sensing SMA probe with specialized electrodes to improve speed and bandwidth while maintaining accuracy. 3D electrical impedance tomography (EIT) reconstructions were generated from ex vivo bovine tissue to characterize probe imaging and to determine an optimal applied pressure range (15 Pa to 38 Pa). Classification accuracy of adipose and muscle tissue was evaluated by comparing the experimental data set to simulated data based on a ground truth binary map of the tissue. Experimental AUCs ≥0.83 were maintained up to 50 kHz. The developed impedance sensing probe successfully classified between muscle and adipose tissue in an ex vivo bovine model. Future work includes improving performance of the SMA probe with custom hardware and collecting data from ex vivo and in vivo prostatic tissues.Clinical Relevance-This technology is expected to reduce the rate of PSMs in RP and decrease the use of post-surgical adjuvant therapies. It is also anticipated that intraoperative impedance measurements will increase efficacy of nerve sparing procedures and reduce complications such as incontinence and erectile dysfunction.


Asunto(s)
Márgenes de Escisión , Neoplasias de la Próstata , Masculino , Humanos , Animales , Bovinos , Impedancia Eléctrica , Recurrencia Local de Neoplasia , Próstata/cirugía , Neoplasias de la Próstata/cirugía
10.
BMJ Open ; 13(4): e067013, 2023 04 18.
Artículo en Inglés | MEDLINE | ID: mdl-37072356

RESUMEN

INTRODUCTION: Food cravings are common in pregnancy and along with emotional eating and eating in the absence of hunger, they are associated with excessive weight gain and adverse effects on metabolic health including gestational diabetes mellitus (GDM). Women with GDM also show poorer mental health, which further can contribute to dysregulated eating behaviour. Food cravings can lead to greater activity in brain centres known to be involved in food 'wanting' and reward valuation as well as emotional eating. They are also related to gestational weight gain. Thus, there is a great need to link implicit brain responses to food with explicit measures of food intake behaviour, especially in the perinatal period. The aim of this study is to investigate the spatiotemporal brain dynamics to visual presentations of food in women during pregnancy and in the post partum, and link these brain responses to the eating behaviour and metabolic health outcomes in women with and without GDM. METHODS AND ANALYSIS: This prospective observational study will include 20 women with and 20 without GDM, that have valid data for the primary outcomes. Data will be assessed at 24-36 weeks gestational age and at 6 months post partum. The primary outcomes are brain responses to food pictures of varying carbohydrate and fat content during pregnancy and in the post partum using electroencephalography. Secondary outcomes including depressive symptoms, current mood and eating behaviours will be assessed with questionnaires, objective eating behaviours will be measured using Auracle and stress will be measured with heart rate and heart rate variability (Actiheart). Other secondary outcome measures include body composition and glycaemic control parameters. ETHICS AND DISSEMINATION: The Human Research Ethics Committee of the Canton de Vaud approved the study protocol (2021-01976). Study results will be presented at public and scientific conferences and in peer-reviewed journals.


Asunto(s)
Diabetes Gestacional , Periodo Posparto , Embarazo , Femenino , Humanos , Lactante , Periodo Posparto/psicología , Diabetes Gestacional/psicología , Conducta Alimentaria , Alimentos , Encéfalo , Estudios Observacionales como Asunto
11.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 869-872, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-36086290

RESUMEN

Surgical drilling to place dental implants in the mandible and maxilla is associated high risk of iatrogenic injuries to inferior alveolar nerve and maxillary sinus. Real-time tissue margin sensing at the drill-tip using electrical impedance spectroscopy (EIS) could reduce this risk by providing feedback to surgeons. Studies with saline analogues, ex-vivo tissues, in-situ tissues and computer models have been previously conducted to evaluate these impedance sensors. Understanding in-vivo electrical properties of tissues in the mandible and maxilla is critical to further develop the sensor and tissue margin sensing algorithms. In this paper, we propose an in-vivo animal model using pigs and discuss methods to test the sensor. Intra-operative imaging and optical tracking systems to assist in surgical navigation are described. The process of registering imaging and tracking information to localize impedance measurement sites within the anatomy are detailed. Results from one in-vivo case of drilling through the mandible are presented and discussed. Clinical Relevance- This model is crucial for characterizing in-vivo electrical properties of mandibular and maxillary tissues encountered during dental implant surgical drilling and for translating bioimpedance sensing drill technology to clinical space.


Asunto(s)
Maxilar , Modelos Anatómicos , Animales , Espectroscopía Dieléctrica , Impedancia Eléctrica , Mandíbula/diagnóstico por imagen , Mandíbula/cirugía , Maxilar/cirugía , Porcinos
12.
Int J Comput Assist Radiol Surg ; 17(6): 1079-1089, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35511394

RESUMEN

PURPOSE: Traditional soft tissue registration methods require direct intraoperative visualization of a significant portion of the target anatomy in order to produce acceptable surface alignment. Image guidance is therefore generally not available during the robotic exposure of structures like the kidneys which are not immediately visualized upon entry into the abdomen. This paper proposes guiding surgical exposure with an iterative state estimator that assimilates small visual cues into an a priori anatomical model as exposure progresses, thereby evolving pose estimates for the occluded structures of interest. METHODS: Intraoperative surface observations of a right kidney are simulated using endoscope tracking and preoperative tomography from a representative robotic partial nephrectomy case. Clinically relevant random perturbations of the true kidney pose are corrected using this sequence of observations in a particle filter framework to estimate an optimal similarity transform for fitting a patient-specific kidney model at each step. The temporal response of registration error is compared against that of serial rigid coherent point drift (CPD) in both static and simulated dynamic surgical fields, and for varying levels of observation persistence. RESULTS: In the static case, both particle filtering and persistent CPD achieved sub-5 mm accuracy, with CPD processing observations 75% faster. Particle filtering outperformed CPD in the dynamic case under equivalent computation times due to the former requiring only minimal persistence. CONCLUSION: This proof-of-concept simulation study suggests that Bayesian state estimation may provide a viable pathway to image guidance for surgical exposure in the abdomen, especially in the presence of dynamic intraoperative tissue displacement and deformation.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Algoritmos , Teorema de Bayes , Humanos , Riñón/diagnóstico por imagen , Riñón/cirugía , Fantasmas de Imagen
13.
IEEE Trans Biomed Eng ; 69(5): 1745-1757, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34813463

RESUMEN

OBJECTIVE: Reducing time-to-treatment and providing acute management in stroke are essential for patient recovery. Electrical bioimpedance (EBI) is an inexpensive and non-invasive tissue measurement approach that has the potential to provide novel continuous intracranial monitoring-something not possible in current standard-of-care. While extensive previous work has evaluated the feasibility of EBI in diagnosing stroke, high-impedance anatomical features in the head have limited clinical translation. METHODS: The present study introduces novel electrode placements near highly-conductive cerebral spinal fluid (CSF) pathways to enhance electrical current penetration through the skull and increase detection accuracy of neurologic damage. Simulations were conducted on a realistic finite element model (FEM). Novel electrode placements at the tear ducts, soft palate and base of neck were evaluated. Classification accuracy was assessed in the presence of signal noise, patient variability, and electrode positioning. RESULTS: Algorithms were developed to successfully determine stroke etiology, location, and size relative to impedance measurements from a baseline scan. Novel electrode placements significantly increased stroke classification accuracy at various levels of signal noise (e.g., p < 0.001 at 40 dB). Novel electrodes also amplified current penetration, with up to 30% increase in current density and 57% increased sensitivity in central intracranial regions (p < 0.001). CONCLUSION: These findings support the use of novel electrode placements in EBI to overcome prior limitations, indicating a potential approach to increasing the technology's clinical utility in stroke identification. SIGNIFICANCE: A non-invasive EBI monitor for stroke could provide essential timely intervention and care of stroke patients.


Asunto(s)
Algoritmos , Accidente Cerebrovascular , Impedancia Eléctrica , Electrodos , Análisis de Elementos Finitos , Humanos , Accidente Cerebrovascular/diagnóstico
14.
Ann Biomed Eng ; 50(1): 94-107, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34993696

RESUMEN

Retractors and scopes used in head and neck surgery to provide adequate surgical exposure also deform critical structures in the region. Surgeons typically use preoperative imaging to plan and guide their tumor resections, however the large tissue deformation resulting from placement of retractors and scopes reduces the utility of preoperative imaging as a reliable roadmap. We quantify the extent of tumor and vasculature deformation in patients with tumors of the larynx and pharynx undergoing diagnostic laryngoscopy. A mean tumor displacement of 1.02 cm was observed between the patients' pre- and intra-operative states. Mean vasculature displacement at key bifurcation points was 0.99 cm. Registration to the hyoid bone can reduce tumor displacement to 0.67 cm and improve carotid stem angle deviations but increase overall vasculature displacement. The large deformation results suggest limitations in reliance on preoperative imaging and that using specific landmarks intraoperatively or having more intraoperative information could help to compensate for these deviations and ultimately improve surgical success.


Asunto(s)
Laringe , Neoplasias , Humanos , Laringoscopía/métodos , Laringe/diagnóstico por imagen , Microcirugia , Faringe
15.
Physiol Meas ; 43(5)2022 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-35508144

RESUMEN

Objective.Analyze the performance of electrical impedance tomography (EIT) in an innovative porcine model of subclinical hemorrhage and investigate associations between EIT and hemodynamic trends.Approach. Twenty-five swine were bled at slow rates to create an extended period of subclinical hemorrhage during which the animal's heart rate (HR) and blood pressure (BP) remained stable from before hemodynamic deterioration, where stable was defined as <15% decrease in BP and <20% increase in HR-i.e.hemorrhages were hidden from standard vital signs of HR and BP. Continuous vital signs, photo-plethysmography, and continuous non-invasive EIT data were recorded and analyzed with the objective of developing an improved means of detecting subclinical hemorrhage-ideally as early as possible.Main results. Best area-under-the-curve (AUC) values from comparing bleed to no-bleed epochs were 0.96 at a 80 ml bleed (∼15.4 min) using an EIT-data-based metric and 0.79 at a 120 ml bleed (∼23.1 min) from invasively measured BP-i.e.the EIT-data-based metric achieved higher AUCs at earlier points compared to standard clinical metrics without requiring image reconstructions.Significance.In this clinically relevant porcine model of subclinical hemorrhage, EIT appears to be superior to standard clinical metrics in early detection of hemorrhage.


Asunto(s)
Hemorragia , Tomografía , Animales , Impedancia Eléctrica , Hemorragia/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Porcinos , Tomografía/métodos , Tomografía Computarizada por Rayos X
16.
Prostate ; 71(16): 1759-67, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21520155

RESUMEN

BACKGROUND: The electrical properties of prostate tissues are dependent on cellular morphology and have been demonstrated to distinguish between benign and malignant formations. Because Gleason grading is also based on tissue architecture we explored the hypothesis that the electrical properties might also provide discriminating power between high- and low-Gleason grade cancers. METHODS: Electrical properties (σ, ε, Δσ, σ(∞) , f(c) , and α) were gauged from 546 prostate tissue samples and correlated with histopathological assessment. Primary and secondary Gleason grades and a Gleason score were assigned to the tissues identified as cancer. We evaluated how well differently graded cancers were separable from benign tissues and from each other on the basis of these properties using ROC curves. RESULTS: Of the 546 prostate tissue samples, 71 were identified as cancer and 465 as benign. ε, Δσ, σ(∞) , and f(c) provided the most discriminatory power with area under the curves (AUCs) ranging from 0.77-0.82 for detecting any cancer, 0.72-0.8 for low-grade cancer, and increasing to 0.87-0.9 for detecting high-grade cancer. Further, ε, Δσ, and σ(∞) , provided AUCs ranging from 0.74 to 0.75 for discriminating between low- and high-grade cancers. CONCLUSIONS: Using the electrical properties to identify prostate cancer is improved when high-grade cancers are sought. These electrical properties can also discriminate between different grades of tumors. These findings suggest that technologies being developed to sense and image these properties in vivo may discriminate between aggressive and indolent lesions.


Asunto(s)
Adenocarcinoma/diagnóstico , Espectroscopía Dieléctrica/métodos , Neoplasias/diagnóstico , Neoplasias de la Próstata/diagnóstico , Adenocarcinoma/patología , Biopsia , Diagnóstico Diferencial , Impedancia Eléctrica , Humanos , Masculino , Clasificación del Tumor , Neoplasias/patología , Neoplasias de la Próstata/patología , Curva ROC
17.
Artículo en Inglés | MEDLINE | ID: mdl-34745771

RESUMEN

As the United States population ages, managing pathologies that largely affect older adults, including sarcopenia (i.e., loss of muscle mass and strength) represents a significant and growing clinical challenge. In addition to increased rates of sarcopenia with age, its incidence and impact increase after acute illness, increasing the risk of functional decline, institutionalization, or death. Resistance-based exercises promote muscle regeneration and strength and are an advised therapy for such patients. Yet, such therapeutic exercises are normally conducted either under direct clinical oversight or unsupervised by patients at home, where compliance rates are low. The presented device, BandPass, aims to create an integrated force data detection and acquisition system for monitoring and transmitting at-home exercise force data to patients and clinicians. A potentiometer-based sensor was integrated to a resistance exercise band through the use of custom designed electronics, which incorporated Bluetooth Low Energy (BLE) for wireless transmission to a mobile 'app'. A protocol for calibrating the device was developed using a range of loads and validated in static benchtop and dynamic testing. Data from a pilot study with 7 older adults was also collected and analyzed to test the device. BandPass is 94% accurate with a coefficient of variation (CoV) of 4.9% and sensitivity of 150g. The pilot study recorded 147 exercises, allowing for analysis on patients' exercise performances. BandPass was successfully able to measure force continuously over time during exercises, measure longitudinal compliance with exercises, and quantify force continuously over time. A mobile health (mHealth) force-sensing system allows for the remote monitoring of prescribed in-home resistance exercise band programs for at-risk older adults, bridging the gap between clinicians and patients.

18.
Health Technol (Berl) ; 5(1): 4, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34336543

RESUMEN

BACKGROUND: Resistance-based exercises effectively enhance muscle strength, which is especially important in older populations as it reduces the risk of disability. Our group developed a Bluetooth-enabled handle for resistance exercise bands that wirelessly transmits relative force data through low-energy Bluetooth to a local smartphone or similar device. We present a usability assessment that evaluates an exercise system featuring a novel Bluetooth-enabled resistance exercise band, ultimately intended to expand the accessibility of resistance training through technology-enhanced home-based exercise programs for older adults. Although our target population is older adults, we assess the user experience among younger adults as a convenient and meaningful starting point in the testing and development of our device. METHODS: There were 32 young adults participating in three exercise sessions with the exercise band, after which each completed an adapted version of the Usefulness, Satisfaction, and Ease (USE) questionnaire to characterize the exercise system's strengths and weaknesses in usability. RESULTS: Questionnaire data reflected a positive and consistent user experience, with all 20 items receiving mean scores greater than 5.0 on a seven-point Likert scale. There were no specific areas of significant weakness in the device's user experience. CONCLUSIONS: The positive reception among young adults is a promising indication that the device can be successfully incorporated into exercise interventions and that the system can be further developed and tested for the target population of older adults.

19.
Cancer Imaging ; 21(1): 61, 2021 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-34802462

RESUMEN

BACKGROUND: Indices obtained from lymph node dissection specimens, specifically lymph node yield (LNY) and lymph node ratio (LNR), have prognostic significance in the setting of head and neck squamous cell carcinoma (HNSCCa). However, there are currently no validated tools to estimate adequacy of planned lymph node dissection using preoperative data. The present study sought to evaluate CT-derived estimates of lymphatic tissue volumes as a preoperative tool to guide cervical node dissection. METHODS: Fifteen cervical lymph node dissections were performed in 14 subjects with HNSCCa. Preoperative CT-derived estimates of lymphatic tissue volumes were compared with gross pathology tissue volume estimates and pathologically-determined LNY. RESULTS: Resected tissue volume (calculated using the triaxial ellipsoid method) correlates with CT-derived preoperative lymphatic volume estimates (r = 0.74, p = 0.003) while LNY does not(r = - 0.12, p = 0.67). When excluding pathologically enlarged lymph nodes ("refined" data), a negative correlation was observed between refined CT-derived volume estimates and refined LNY (r = - 0.65, p = 0.009). CONCLUSION: In the setting of cervical lymph node dissection, CT-derived lymphatic volume estimates correlate with resected tissue volume, but refined CT-derived volume estimates correlate negatively with refined LNY. TRIAL REGISTRATION: Retrospectively registered. LEVEL OF EVIDENCE: 4.


Asunto(s)
Neoplasias de Cabeza y Cuello , Escisión del Ganglio Linfático , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/cirugía , Humanos , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/cirugía , Metástasis Linfática , Carcinoma de Células Escamosas de Cabeza y Cuello/diagnóstico por imagen , Carcinoma de Células Escamosas de Cabeza y Cuello/cirugía , Tomografía Computarizada por Rayos X
20.
Physiol Rep ; 9(8): e14782, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33931957

RESUMEN

Internal jugular flow is reduced in space compared with supine values, which can be associated with internal jugular vein (IJV) thrombosis. The mechanism is unknown but important to understand to prevent potentially serious vein thromboses on long duration flights. We used a novel, microgravity-focused numerical model of the cranial vascular circulation to develop hypotheses for the reduced flow. This model includes the effects of removing hydrostatic gradients and tissue compressive forces - unique effects of weightlessness. The IJV in the model incorporates sensitivity to transmural pressure across the vein, which can dramatically affect resistance and flow in the vein. The model predicts reduced IJV flow in space. Although tissue weight in the neck is reduced in weightlessness, increasing transmural pressure, this is more than offset by the reduction in venous pressure produced by the loss of hydrostatic gradients and tissue pressures throughout the body. This results in a negative transmural pressure and increased IJV resistance. Unlike the IJV, the walls of the vertebral plexus are rigid; transmural pressure does not affect its resistance and so its flow increases in microgravity. This overall result is supported by spaceflight measurements, showing reduced IJV area inflight compared with supine values preflight. Significantly, this hypothesis suggests that interventions that further decrease internal IJV pressure (such as lower body negative pressure), which are not assisted by other drainage mechanisms (e.g. gravity), might lead to stagnant flow or IJV collapse with reduced flow, which could increase rather than decrease the risk of venous thrombosis.


Asunto(s)
Simulación por Computador , Venas Yugulares/fisiología , Flujo Sanguíneo Regional , Ingravidez/efectos adversos , Humanos , Venas Yugulares/diagnóstico por imagen , Posición Supina