1.
Otolaryngol Head Neck Surg ; 132(3): 435-42, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15746858

RESUMEN

OBJECTIVES: Application of image-guided surgery to otology has been limited by the need for submillimeter accuracy via a fiducial system that is easily usable (noninvasive and nonobstructive). METHODS: A dental bite-block was fitted with a rigid frame with 7 fiducial markers surrounding each external ear. The temporal bones of 3 cadaveric skulls were removed and replaced with surgical targets arranged in a bull's-eye pattern about the centroid of each temporal bone. The surgical targets were identified both within CT scans and in physical space using an infrared optical tracking system. The difference between positions in CT space versus physical space was calculated as target registration error. RESULTS: A total of 234 independent target registration errors were calculated. Mean +/- standard deviation = 0.73 mm +/- 0.25 mm. CONCLUSIONS: These findings show that image-guided otologic surgery with submillimeter accuracy is achievable with a minimally invasive fiducial frame. Significance In vivo validation of the system is ongoing. With such validation, this system may facilitate clinically applicable image-guided otologic surgery. EBM RATING: A.


Asunto(s)
Procedimientos Quirúrgicos Otorrinolaringológicos/métodos , Cirugía Asistida por Computador , Hueso Temporal/cirugía , Humanos , Técnicas In Vitro , Reproducibilidad de los Resultados
2.
Comput Aided Surg ; 9(4): 145-53, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-16192054

RESUMEN

OBJECTIVE: Otologic surgery is undertaken to treat ailments of the ear, including persistent infections, hearing loss, vertigo, and cancer. Typically performed on otherwise-healthy patients in outpatient facilities, the application of image-guided surgery (IGS) has been limited because accurate (<1 mm), non-invasive fiducial systems for otologic surgery have not been available. We now present such a fiducial system. METHODS: A dental bite-block was fitted with a custom-designed rigid frame with 7 fiducial markers surrounding each external ear. The bones containing the ear (i.e., the temporal bones) of 3 cadaveric skulls were removed and replaced with discs containing 13 surgical targets arranged in a cross-hair pattern about the centroid of each ear. The surgical targets (26/skull) and fiducial markers (14/skull) were identified both within CT scans using a published algorithm and in physical space using an infrared optical tracking system. Fiducial registration error (FRE), fiducial localization error (FLE), and target registration error (TRE) were calculated. RESULTS: For all trials, root mean square FRE = 0.66, FLE = 0.72, and TRE = 0.77 mm. The mean TRE for n = 234 independent targets was 0.73 with a standard deviation of 0.25 mm. CONCLUSIONS: Using a novel, non-invasive fiducial system (the EarMark), submillimetric accuracy was repeatably achieved. This system will facilitate image-guided otologic surgery.


Asunto(s)
Monitoreo Intraoperatorio/instrumentación , Procedimientos Quirúrgicos Otológicos , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X , Artefactos , Humanos , Maxilar/diagnóstico por imagen , Maxilar/cirugía , Modelos Anatómicos , Fantasmas de Imagen