RESUMEN
Kinases are an important therapeutic target for drug discovery, and many cancer chemotherapeutic agents have been derived from natural product sources. Natural product samples, however, have the likelihood of assay interference, particularly at elevated test concentrations. The authors developed a competitive fluorescence polarization (FP) assay using red-shifted fluorophores for the AKT kinase and demonstrated utility for testing concentrated natural product extracts. A set of 7 actinomycetes cultures containing indolocarbazoles, known nonselective kinase inhibitors, and a control set of 22 nonproducing indolocarbazole cultures were evaluated. Using red-shifted dyes (Cy3B or Cy5), the authors identified active samples with minimal interference up to the extract concentrations that are 3 times nonextracted culture levels. In contrast, a significant number of interferences were observed using either a fluorescein competitive FP assay or a [33P]ATP Flashplate assay. This work demonstrates that one can screen natural product extracts at high concentrations successfully using FP technology with red-shifted dyes.
Asunto(s)
Factores Biológicos/metabolismo , Polarización de Fluorescencia/métodos , Colorantes Fluorescentes/química , Proteínas Serina-Treonina Quinasas/metabolismo , Proteínas Proto-Oncogénicas/metabolismo , Cromatografía Líquida de Alta Presión , Fermentación , Proteínas Proto-Oncogénicas c-akt , Espectrofotometría UltravioletaRESUMEN
With the increasing use of fluorescence-based assays in high-throughput screening (HTS), the possibility of interference by fluorescent compounds needs to be considered. To investigate compound interference, a well-defined sample set of biologically active compounds, LOPAC, was evaluated using 4 fluorescein-based fluorescence polarization (FP) assays. Two kinase assays, a protease assay, and a phosphatase assay were studied. Fluorescent compound interference and light scattering were observed in both mixture- and single-compound testing under certain circumstances. In the kinase assays, which used low levels (1-3 nM) of fluorophore, an increase in total fluorescence, an abnormal decrease in mP readings, and negative inhibition values were attributed to compound fluorescence. Light scattering was observed by an increase in total fluorescence and minimal reduction in mP, leading to false positives. The protease and phosphatase assays, which used a higher concentration of fluorophore (20-1200 nM) than the kinase assays, showed minimal interference from fluorescent compounds, demonstrating that an increase in the concentration of the fluorophore minimized potential fluorescent compound interference. The data also suggests that mixtures containing fluorescent compounds can result in either false negatives that can mask a potential "hit" or false positives, depending on the assay format. Cy dyes (e.g., Cy3B and Cy5 ) excite and emit further into the red region than fluorescein and, when used in place of fluorescein in kinase 1, eliminate fluorescence interference and light scattering by LOPAC compounds. This work demonstrates that fluorescent compound and light scattering interferences can be overcome by increasing the fluorophore concentration in an assay or by using longer wavelength dyes.