Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Am J Physiol Heart Circ Physiol ; 326(5): H1094-H1104, 2024 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-38426864

RESUMEN

Obstructive sleep apnea (OSA) is associated with the progression of cardiovascular diseases, arrhythmias, and sudden cardiac death (SCD). However, the acute impacts of OSA and its consequences on heart function are not yet fully elucidated. We hypothesized that desaturation events acutely destabilize ventricular repolarization, and the presence of accompanying arousals magnifies this destabilization. Ventricular repolarization lability measures, comprising heart rate corrected QT (QTc), short-time-variability of QT (STVQT), and QT variability index (QTVI), were calculated before, during, and after 20,955 desaturations from lead II electrocardiography signals of 492 patients with suspected OSA (52% men). Variations in repolarization parameters were assessed during and after desaturations, both with and without accompanying arousals, and groupwise comparisons were performed based on desaturation duration and depth. Regression analyses were used to investigate the influence of confounding factors, comorbidities, and medications. The standard deviation (SD) of QT, mean QTc, SDQTc, and STVQT increased significantly (P < 0.01), whereas QTVI decreased (P < 0.01) during and after desaturations. The changes in SDQT, mean QTc, SDQTc, and QTVI were significantly amplified (P < 0.01) in the presence of accompanying arousals. Desaturation depth was an independent predictor of increased SDQTc (ß = 0.405, P < 0.01), STVQT (ß = 0.151, P < 0.01), and QTVI (ß = 0.009, P < 0.01) during desaturation. Desaturations cause acute changes in ventricular repolarization, with deeper desaturations and accompanying arousals independently contributing to increased ventricular repolarization lability. This may partially explain the increased risk of arrhythmias and SCD in patients with OSA, especially when the OSA phenotype includes high hypoxic load and fragmented sleep.NEW & NOTEWORTHY Nocturnal desaturations are associated with increased ventricular repolarization lability. Deeper desaturations with accompanying arousals increase the magnitude of alterations, independent of confounding factors, comorbidities, and medications. Changes associated with desaturations can partially explain the increased risk of arrhythmias and sudden cardiac death in patients with OSA, especially in patients with high hypoxic load and fragmented sleep. This highlights the importance of detailed electrocardiogram analytics for patients with OSA.


Asunto(s)
Arritmias Cardíacas , Apnea Obstructiva del Sueño , Masculino , Humanos , Femenino , Muerte Súbita Cardíaca/etiología , Apnea Obstructiva del Sueño/complicaciones , Nivel de Alerta , Electrocardiografía/efectos adversos , Frecuencia Cardíaca/fisiología , Hipoxia/complicaciones
2.
Sensors (Basel) ; 22(15)2022 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-35957328

RESUMEN

Heart rate variability (HRV) has been studied for decades in clinical environments. Currently, the exponential growth of wearable devices in health monitoring is leading to new challenges that need to be solved. These devices have relatively poor signal quality and are affected by numerous motion artifacts, with data loss being the main stumbling block for their use in HRV analysis. In the present paper, it is shown how data loss affects HRV metrics in the time domain and frequency domain and Poincaré plots. A gap-filling method is proposed and compared to other existing approaches to alleviate these effects, both with simulated (16 subjects) and real (20 subjects) missing data. Two different data loss scenarios have been simulated: (i) scattered missing beats, related to a low signal to noise ratio; and (ii) bursts of missing beats, with the most common due to motion artifacts. In addition, a real database of photoplethysmography-derived pulse detection series provided by Apple Watch during a protocol including relax and stress stages is analyzed. The best correction method and maximum acceptable missing beats are given. Results suggest that correction without gap filling is the best option for the standard deviation of the normal-to-normal intervals (SDNN), root mean square of successive differences (RMSSD) and Poincaré plot metrics in datasets with bursts of missing beats predominance (p<0.05), whereas they benefit from gap-filling approaches in the case of scattered missing beats (p<0.05). Gap-filling approaches are also the best for frequency-domain metrics (p<0.05). The findings of this work are useful for the design of robust HRV applications depending on missing data tolerance and the desired HRV metrics.


Asunto(s)
Benchmarking , Dispositivos Electrónicos Vestibles , Artefactos , Electrocardiografía , Frecuencia Cardíaca/fisiología , Humanos , Fotopletismografía
3.
Philos Trans A Math Phys Eng Sci ; 379(2212): 20200261, 2021 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-34689618

RESUMEN

Stress test electrocardiogram (ECG) analysis is widely used for coronary artery disease (CAD) diagnosis despite its limited accuracy. Alterations in autonomic modulation of cardiac electrical activity have been reported in CAD patients during acute ischemia. We hypothesized that those alterations could be reflected in changes in ventricular repolarization dynamics during stress testing that could be measured through QT interval variability (QTV). However, QTV is largely dependent on RR interval variability (RRV), which might hinder intrinsic ventricular repolarization dynamics. In this study, we investigated whether different markers accounting for low-frequency (LF) oscillations of QTV unrelated to RRV during stress testing could be used to separate patients with and without CAD. Power spectral density of QTV unrelated to RRV was obtained based on time-frequency coherence estimation. Instantaneous LF power of QTV and QTV unrelated to RRV were obtained. LF power of QTV unrelated to RRV normalized by LF power of QTV was also studied. Stress test ECG of 100 patients were analysed. Patients referred to coronary angiography were classified into non-CAD or CAD group. LF oscillations in QTV did not show significant differences between CAD and non-CAD groups. However, LF oscillations in QTV unrelated to RRV were significantly higher in the CAD group as compared with the non-CAD group when measured during the first phases of exercise and last phases of recovery. ROC analysis of these indices revealed area under the curve values ranging from 61 to 73%. Binomial logistic regression analysis revealed LF power of QTV unrelated to RRV, both during the first phase of exercise and last phase of recovery, as independent predictors of CAD. In conclusion, this study highlights the importance of removing the influence of RRV when measuring QTV during stress testing for CAD identification and supports the added value of LF oscillations of QTV unrelated to RRV to diagnose CAD from the first minutes of exercise. This article is part of the theme issue 'Advanced computation in cardiovascular physiology: new challenges and opportunities'.


Asunto(s)
Enfermedad de la Arteria Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Electrocardiografía , Prueba de Esfuerzo , Frecuencia Cardíaca , Humanos
4.
Scand J Med Sci Sports ; 31(2): 339-349, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33038026

RESUMEN

Under the hypothesis that sympathetic control of ventricular repolarization may change once the second ventilatory threshold (VT2) has been reached, a novel methodology for non-invasive VT2 estimation based on the analysis of the T wave from the electrocardiogram (ECG) is proposed, and potential underlying physiological mechanisms are suggested. 25 volunteers (33.4 ± 5.2 years) underwent an incremental power cycle ergometer test (25 W/minute). During the test, respiratory gas exchange and multi-lead ECG were acquired. The former was employed to determine VT2, used here as a reference, whereas the latter was used to compute the temporal profiles of an index of ventricular repolarization instability (dT) and its low-frequency (LF) oscillations (LFdT). The sudden increases observed in dT and LFdT profiles above an established heart rate threshold were employed to derive VT2 estimates, referred to as VT2d T and VT2LF d T , respectively. Estimation errors of -4.7 ± 25.2 W were obtained when considering VT2d T . Errors were lower than the one-minute power increment of 25 W in 68% of the subjects and lower than 50 W in 89.5% of them. When using VT2LF d T , estimation error was of 15.3 ± 32.4 W. Most of the subjects shared common characteristic dT and LFdT profiles, which could be reflecting changes in the autonomic control of ventricular repolarization before and after reaching VT2. The analysis of ventricular repolarization dynamics during exercise allows non-invasive ECG-based estimation of VT2, possibly in relation to changes in the autonomic control of ventricular electrical activity when VT2 is reached.


Asunto(s)
Umbral Anaerobio/fisiología , Electrocardiografía/métodos , Prueba de Esfuerzo/métodos , Frecuencia Cardíaca/fisiología , Función Ventricular/fisiología , Adulto , Sistema Nervioso Autónomo/fisiología , Ejercicio Físico/fisiología , Humanos , Masculino , Intercambio Gaseoso Pulmonar/fisiología , Factores de Tiempo
5.
Sensors (Basel) ; 21(3)2021 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-33572800

RESUMEN

This work aims to validate the Polar H7 heart rate (HR) sensor for heart rate variability (HRV) analysis at rest and during various exercise intensities in a cohort of male volunteers with different age, body composition and fitness level. Cluster analysis was carried out to evaluate how these phenotypic characteristics influenced HR and HRV measurements. For this purpose, sixty-seven volunteers performed a test consisting of the following consecutive segments: sitting rest, three submaximal exercise intensities in cycle-ergometer and sitting recovery. The agreement between HRV indices derived from Polar H7 and a simultaneous electrocardiogram (ECG) was assessed using concordance correlation coefficient (CCC). The percentage of subjects not reaching excellent agreement (CCC > 0.90) was higher for high-frequency power (PHF) than for low-frequency power (PLF) of HRV and increased with exercise intensity. A cluster of unfit and not young volunteers with high trunk fat percentage showed the highest error in HRV indices. This study indicates that Polar H7 and ECG were interchangeable at rest. During exercise, HR and PLF showed excellent agreement between devices. However, during the highest exercise intensity, CCC for PHF was lower than 0.90 in as many as 60% of the volunteers. During recovery, HR but not HRV measurements were accurate. As a conclusion, phenotypic differences between subjects can represent one of the causes for disagreement between HR sensors and ECG devices, which should be considered specifically when using Polar H7 and, generally, in the validation of any HR sensor for HRV analysis.


Asunto(s)
Electrocardiografía , Ejercicio Físico , Frecuencia Cardíaca , Adulto , Anciano , Composición Corporal , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
6.
Sensors (Basel) ; 18(8)2018 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-30103376

RESUMEN

Heart rate variability (HRV) analysis is a noninvasive tool widely used to assess autonomic nervous system state. The market for wearable devices that measure the heart rate has grown exponentially, as well as their potential use for healthcare and wellbeing applications. Still, there is a lack of validation of these devices. In particular, this work aims to validate the Apple Watch in terms of HRV derived from the RR interval series provided by the device, both in temporal (HRM (mean heart rate), SDNN, RMSSD and pNN50) and frequency (low and high frequency powers, LF and HF) domain. For this purpose, a database of 20 healthy volunteers subjected to relax and a mild cognitive stress was used. First, RR interval series provided by Apple Watch were validated using as reference the RR interval series provided by a Polar H7 using Bland-Altman plots and reliability and agreement coefficients. Then, HRV parameters derived from both RR interval series were compared and their ability to identify autonomic nervous system (ANS) response to mild cognitive stress was studied. Apple Watch measurements presented very good reliability and agreement (>0.9). RR interval series provided by Apple Watch contain gaps due to missing RR interval values (on average, 5 gaps per recording, lasting 6.5 s per gap). Temporal HRV indices were not significantly affected by the gaps. However, they produced a significant decrease in the LF and HF power. Despite these differences, HRV indices derived from the Apple Watch RR interval series were able to reflect changes induced by a mild mental stress, showing a significant decrease of HF power as well as RMSSD in stress with respect to relax, suggesting the potential use of HRV measurements derived from Apple Watch for stress monitoring.


Asunto(s)
Frecuencia Cardíaca/fisiología , Monitoreo Ambulatorio/normas , Estrés Psicológico/fisiopatología , Dispositivos Electrónicos Vestibles/normas , Sistema Nervioso Autónomo/fisiología , Voluntarios Sanos , Humanos , Reproducibilidad de los Resultados
7.
J Strength Cond Res ; 32(3): 716-725, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27749728

RESUMEN

Hernando, D, Garatachea, N, Almeida, R, Casajús, JA, and Bailón, R. Validation of heart rate monitor Polar RS800 for heart rate variability analysis during exercise. J Strength Cond Res 32(3): 716-725, 2018-Heart rate variability (HRV) analysis during exercise is an interesting noninvasive tool to measure the cardiovascular response to the stress of exercise. Wearable heart rate monitors are a comfortable option to measure interbeat (RR) intervals while doing physical activities. It is necessary to evaluate the agreement between HRV parameters derived from the RR series recorded by wearable devices and those derived from an electrocardiogram (ECG) during dynamic exercise of low to high intensity. Twenty-three male volunteers performed an exercise stress test on a cycle ergometer. Subjects wore a Polar RS800 device, whereas ECG was also recorded simultaneously to extract the reference RR intervals. A time-frequency spectral analysis was performed to extract the instantaneous mean heart rate (HRM), and the power of low-frequency (PLF) and high-frequency (PHF) components, the latter centered on the respiratory frequency. Analysis was done in intervals of different exercise intensity based on oxygen consumption. Linear correlation, reliability, and agreement were computed in each interval. The agreement between the RR series obtained from the Polar device and from the ECG is high throughout the whole test although the shorter the RR is, the more differences there are. Both methods are interchangeable when analyzing HRV at rest. At high exercise intensity, HRM and PLF still presented a high correlation (ρ > 0.8) and excellent reliability and agreement indices (above 0.9). However, the PHF measurements from the Polar showed reliability and agreement coefficients around 0.5 or lower when the level of the exercise increases (for levels of O2 above 60%).


Asunto(s)
Ejercicio Físico/fisiología , Frecuencia Cardíaca/fisiología , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/normas , Adulto , Electrocardiografía , Ergometría , Prueba de Esfuerzo , Humanos , Masculino , Consumo de Oxígeno/fisiología , Reproducibilidad de los Resultados , Frecuencia Respiratoria/fisiología , Descanso/fisiología
8.
Braz J Phys Ther ; 28(3): 101079, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38865832

RESUMEN

BACKGROUND: The physical therapy profession has made efforts to increase the use of confidence intervals due to the valuable information they provide for clinical decision-making. Confidence intervals indicate the precision of the results and describe the strength and direction of a treatment effect measure. OBJECTIVES: To determine the prevalence of reporting of confidence intervals, achievement of intended sample size, and adjustment for multiple primary outcomes in randomised trials of physical therapy interventions. METHODS: We randomly selected 100 trials published in 2021 and indexed on the Physiotherapy Evidence Database. Two independent reviewers extracted the number of participants, any sample size calculation, and any adjustments for multiple primary outcomes. We extracted whether at least one between-group comparison was reported with a 95 % confidence interval and whether any confidence intervals were interpreted. RESULTS: The prevalence of use of confidence intervals was 47 % (95 % CI 38, 57). Only 6 % of trials (95 % CI: 3, 12) both reported and interpreted a confidence interval. Among the 100 trials, 59 (95 % CI: 49, 68) calculated and achieved the required sample size. Among the 100 trials, 19 % (95 % CI: 13, 28) had a problem with unadjusted multiplicity on the primary outcomes. CONCLUSIONS: Around half of trials of physical therapy interventions published in 2021 reported confidence intervals around between-group differences. This represents an increase of 5 % from five years earlier. Very few trials interpreted the confidence intervals. Most trials reported a sample size calculation, and among these most achieved that sample size. There is still a need to increase the use of adjustment for multiple comparisons.


Asunto(s)
Modalidades de Fisioterapia , Ensayos Clínicos Controlados Aleatorios como Asunto , Humanos , Tamaño de la Muestra , Intervalos de Confianza
9.
ERJ Open Res ; 10(5)2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39469266

RESUMEN

Aims: Obstructive sleep apnoea (OSA) imposes significant stress on the cardiovascular system and the heart. While long-term cardiac effects are understood, the immediate impact of hypoxaemia on the heart's electrophysiology lacks understanding. Our study aims to explore desaturation severity on cardiovascular repolarisation. Methods: We retrospectively analysed ECGs from full diagnostic polysomnographies from 492 patients with suspected OSA. The analyses were conducted before, during and after 9137 nocturnal apnoea- or hypopnoea-related desaturations. The mean and sd of T-wave amplitude change from the baseline level to the level during and after desaturations (ΔTamp_mean and ΔTamp_SD) were calculated. To investigate the modulatory effects of desaturation severity, the data were divided into subgroups based on the desaturation duration (Tdes; 10 s≤Tdes<20 s, 20 s≤Tdes<30 s, 30 s≤Tdes<45 s and Tdes≥45 s) and magnitude of blood oxygen saturation drop (change in peripheral oxygen saturation (ΔS pO2 ); 3%≤ΔS pO2 <4.5%, 4.5%≤ΔS pO2 <6%, 6%≤ΔS pO2 <7.5% and ΔS pO2 ≥7.5%) for men and women. Results: Desaturations caused significant (p<0.01) changes in ΔTamp_mean during and after desaturations. In men, the median ΔTamp_mean during and after deep (ΔS pO2 ≥7.5%) desaturations were 21 µV and 24 µV, respectively. In women, the median ΔTamp_mean in deep desaturations was 15 µV during and 21 µV after desaturations. Similarly, the ΔTamp_SD increased during and after deep desaturations. In regression analysis, the desaturation depth was an independent predictor for ventricular repolarisation instability. Conclusion: We found an association between the severity of nocturnal desaturations and cardiac repolarisation instability. These findings hold particular importance, as repolarisation instability has been linked with cardiovascular morbidity and could potentially serve as a trigger for arrhythmias and sudden cardiac death.

10.
Rev Diabet Stud ; 19(1): 14-27, 2023 03 31.
Artículo en Inglés | MEDLINE | ID: mdl-37185053

RESUMEN

In type 2 diabetes, therapeutic failure to the oral anti diabetics is frequent, the use of schemes with basal insulin or with multiple doses of insulin (basal insulin and short-acting insulins) are a widely accepted way to intensify therapy. The use of GLP-1 receptor agonists is another intensification strategy. The fixedratio combinations with molecules such as insulin degludec + liraglutide, and insulin glargine + lixisenatide have proven useful in intensifying treatment of individuals with type 2 diabetes. The purpose of this review was to evaluate and analyze the results of pivotal studies with both fixed-ratio combinations in individuals with type 2 diabetes, finding that, they are capable of achieving better glycemic control when compared with each of its components separately (with a lower risk of hypoglycemia vs basal insulin and lower risk of gastrointestinal adverse effects vs GLP-1 receptor agonists) in various clinical scenarios, especially in individuals who do not achieve control with oral antidiabetics or who do not achieve control with basal insulin (associated with oral antidiabetics) or in those under management with GLP-1RA plus oral antidiabetics.


Asunto(s)
Diabetes Mellitus Tipo 2 , Humanos , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Receptor del Péptido 1 Similar al Glucagón/agonistas , Receptor del Péptido 1 Similar al Glucagón/uso terapéutico , Combinación de Medicamentos , Hipoglucemiantes/efectos adversos , Insulina , Liraglutida/uso terapéutico , Liraglutida/efectos adversos , Glucemia
11.
Artículo en Inglés | MEDLINE | ID: mdl-36443975

RESUMEN

BACKGROUND: The population prevalence of functional alterations and thyroid autoimmunity is high, and numerous genetic and environmental aspects have been described as triggering factors. OBJECTIVES: The objective of this study was to determine the prevalence of functional alterations and thyroid autoimmunity in an urban population of Colombia. MATERIALS AND METHODS: It is a cross-sectional, population-based study (n = 9,638) conducted on an urban population of Popayán-Cauca-Colombia between February 5th, 2018, to December 11th, 2021. The variables evaluated were thyrotropin (TSH), free T4 (FT4), and anti-thyroid antibodies (thyroid peroxidase antibodies: TPOAb, and thyroglobulin antibodies: TgAb). RESULTS: TSH in men was significantly higher than in women. No differences were observed in the values of FT4, TPOAb, and TgAb (according to sex). The prevalence of normal thyroid function and subclinical hypothyroidism was significantly higher in men. The positivity of TPOAb and TgAb was 22.3% and 19.2%, respectively. TSH levels increased with age (both in men and in women). In participants with normal FT4 and negative TPOAb, the TSH was significantly higher. TSH was significantly higher in TPOAb-positive individuals and among those with TPOAb and TgAb positives, as well as in women with positive TPOAb and men with positive TPOAb and TgAb. CONCLUSION: In an urban population of Colombia, TSH was found to be higher than in populations of other geographical areas, especially in older individuals and in the presence of positive anti-thyroid antibodies, a high prevalence of functional alterations and thyroid autoimmunity was also found. These findings can be explained by excess iodine consumption and some environmental factors.


Asunto(s)
Autoanticuerpos , Autoinmunidad , Masculino , Humanos , Femenino , Anciano , Población Urbana , Prevalencia , Estudios Transversales , Colombia/epidemiología , Tirotropina
12.
J Clin Med ; 12(19)2023 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-37834959

RESUMEN

BACKGROUND: Cluster headache (CH) is a type of headache that has a global prevalence of 0.5-3/1000 people, provokes severe, strictly unilateral pain through the first branch of the trigeminal nerve, and is associated with observable autonomous responses. CH provokes intense pain and decreases quality of life. OBJECTIVE: In this study, we aimed to carry out a systematic review of the effectiveness of non-invasive neuromodulation of the vagus nerve in patients with cluster headaches, which was registered on PROSPERO No. CRD42021265126. METHODS: Six databases were used from their date of inception to February 2023 to obtain studies with the group intervention of non-invasive neuromodulation of the vagus nerve for cluster headache, with outcomes based on pain attacks, duration, and disabilities. Data on the subjects, group intervention, main outcomes, and results were collected by two authors. RESULTS: The search provided 1003 articles, with three clinical trials being eligible for inclusion in the review. The methodological quality scores ranged from 6 to 8 points (mean: 7.3, SD: 0.8) out of a maximum of 10 points. The post-treatment results showed some positive effects using n-VNS as a treatment for cluster headache, more specifically regarding cervical neuromodulation of the vagus nerve. CONCLUSIONS: The systematic review found moderate-to-high-quality evidence supporting that n-VNS and cervical n-VNS may have some positive effects at the end of the treatment being effective to relieve the frequency and intensity of cluster headaches. The poor quantity of studies available and the lack of homogeneity in the study protocols did not allow the pooling of data for a meta-analysis.

13.
Front Neurosci ; 17: 1151892, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37397439

RESUMEN

Background: Migraine is a type of primary headache that is accompanied by symptoms such as nausea, vomiting, or sensitivity to light and sound. Objective: The aim of this study was to conduct a systematic review on the effectiveness of non-invasive neuromodulation, auricular transcutaneous vagus nerve stimulation (at-VNS), and electro-ear acupuncture of the vagus nerve in patients with migraine headaches. Methods: Six databases were searched from inception to 15 June 2022 for clinical trials, in which at least one group received any form of non-invasive neuromodulation of the vagus nerve for managing migraine with outcomes collected on pain intensity and related disability. Data, including participants, interventions, blinding strategy, outcomes, and results, were extracted by two reviewers. The methodological quality was assessed with the PEDro scale, ROB, and Oxford scale. Results: The search identified 1,117 publications with nine trials eligible for inclusion in the review. The methodological quality scores ranged from 6 to 8 (mean: 7.3, SD: 0.8) points. Low-quality evidence suggests some positive clinical effects for the treatment of chronic migraine with 1 Hz with at-VNS and ear-electro-acupuncture compared with the control group at post-treatment. Some of the studies provided evidence of the relationship between chronic migraine and a possible positive effect as a treatment with at-VNS and the neurophysiological effects using fMRI. Six of the studies provided evidence using fMRI of the relationship between chronic migraine and a possible positive effect as a treatment with at-VNS and the neurophysiological effects. Regarding all included studies, the level of evidence with the Oxford scale was level 1 (11.17%), six studies were graded as level 2 (66.66%), and two studies were graded as level 3 (22.2%). With the PEDro score, five studies got a low methodological score < 5 and only four got a score superior to 5, being highly methodological quality studies. For ROB, most of the studies were high risk and only a few of them received a low risk of bias. The pain intensity, migraine attacks, frequency, and duration were measured by three studies with positive results at post-treatment. And only 7% reported adverse events using at-VNS. All studies reported results at a post-treatment period in their respective main outcomes. And all studies with fMRI provided strong evidence of the relationship between the Locus Coeruleus, Frontal Cortex, and other superior brain areas with the auricular branch of the Vagus nerve with at-VNS. Conclusion: Some positive effects regarding the effect of non-invasive neuromodulation, auricular transcutaneous vagus nerve stimulation (at-VNS), and electro-ear acupuncture of the vagus nerve on migraine is reported in the current literature, but there are not enough data to obtain strong conclusions. Systematic review registration: This systematic review was registered in the PROSPERO database (registration number: CRD42021265126).

14.
Nutrients ; 15(10)2023 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-37242240

RESUMEN

Vitamin B12 (B12) is necessary for the proper functioning of the central and peripheral nervous systems. Although there is no exact definition for B12 levels, a value of 200 pg/mL is compatible with deficiency, 200-299 pg/mL is considered borderline, and 300 pg/mL is considered normal. In population studies, the prevalence of B12 deficiency ranges between 2.9% and 35%. Furthermore, many medications, such as metformin [for type 2 diabetes mellitus (T2DM)], can cause B12 deficiency. The objectives of this study were to determine the population status of B12 in southwestern Colombia (and the status of B12 in subjects with T2DM). In the total population (participants with and without T2DM), the prevalence of B12 deficiency was 17.8%; that of borderline was 19.3%; and that of normal levels was 62.9%. The prevalence of deficiency increased with age and was significantly higher in those aged ≥60 years (p = 0.000). In T2DM subjects, the prevalence of deficiency was significantly higher concerning those without T2DM (p = 0.002) and was significantly higher in those who received >1 gm/day of metformin (p = 0.001). Thus, the prevalence of deficiency and borderline levels of B12 in our population was high, particularly in those >60 years of age. B12 deficiency was significantly higher in individuals with T2DM than in individuals without T2DM, especially among those receiving high doses of metformin.


Asunto(s)
Diabetes Mellitus Tipo 2 , Metformina , Deficiencia de Vitamina B 12 , Humanos , Persona de Mediana Edad , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/epidemiología , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Vitamina B 12/uso terapéutico , Hipoglucemiantes/uso terapéutico , Colombia/epidemiología , Deficiencia de Vitamina B 12/epidemiología , Deficiencia de Vitamina B 12/tratamiento farmacológico , Metformina/uso terapéutico
15.
J Clin Med ; 12(11)2023 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-37297867

RESUMEN

BACKGROUND: Tinnitus is the perception of sound in the absence of actual external stimuli. Other associated symptoms include frustration, annoyance, anxiety, depression, stress, cognitive dysfunction, insomnia, or emotional exhaustion. OBJECTIVE: In this study, we aimed to conduct a systematic review and meta-analysis on the effectiveness of the non-invasive neuromodulation of the vagus nerve in patients with tinnitus. METHODS: Six databases were searched from their date of inception to 15 June 2022 to identify clinical trials in which at least one group received any form of non-invasive neuromodulation of the vagus nerve for tinnitus management, with outcomes based on annoyance and related disability. Data on participants, interventions, blinding strategies, assessment outcomes, and results were extracted by two reviewers. RESULTS: The search identified 183 articles with five clinical trials eligible for inclusion in the review and four for the meta-analysis. The methodological quality scores ranged from 6 to 8 (mean: 7.3, SD: 0.8) points. The meta-analysis identified a significant positive effect on THI post-treatment for unilateral auricular stimulation (hg = 0.69, 95% CI 0.06, 1.32) or transcutaneous nerve stimulation (hg = 0.51, 95% CI 0.1, 0.9) compared with a comparative group. No effect on loudness intensity was observed. CONCLUSION: The results of the meta-analysis suggest that the application of the non-invasive neuromodulation of the vagus nerve has a positive effect post-treatment in terms of related disability in patients with tinnitus, although its clinical relevance is low. No firm conclusions about the effect of the non-invasive neuromodulation of the vagus nerve on tinnitus are available based on the current literature.

16.
Braz J Phys Ther ; 26(1): 100392, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35158222

RESUMEN

BACKGROUND: Access to full-text articles is an essential element of evidence-based practice. OBJECTIVE: Estimate the percentage of articles in the Physiotherapy Evidence Database (PEDro) that have free full-text access and compare free access between PEDro and PubMed. Secondary objectives for access via PEDro: determine if publication year and geographic location impact on free access; determine if adding a link to a portable document format (PDF) locator website would improve free access; and evaluate the association between article characteristics and free access. METHODS: This observational study used a random sample of 200 articles published in 2000-2019 and indexed in PEDro. Data collectors in Australia, Brazil, Nepal, and Spain attempted to access free full text for each article via PEDro. One data collector attempted to access free full text via PubMed. One data collector attempted to access full text via a PDF locator (http://www.pdfsearchengine.net/). The percentage (95% confidence interval [CI]) of articles with free full-text access from PEDro, PubMed, and the PDF locator website were calculated. Logistic regression was used to evaluate the association between free full-text access and article characteristics. RESULTS: Free full text could be accessed via PEDro for 51% of the articles (95% CI: 44, 58). PEDro had 4% higher free access than PubMed (95% CI: 1, 7). Access via PEDro did not vary systematically with time, geographic location, or article characteristics. Access improved by 9% (95% CI: 6, 14) by adding a PDF locator website. CONCLUSIONS: PEDro is a good source of free full-text articles for physical therapists and other rehabilitation professionals. Evidence resources, professional organisations, employers, researchers, and research agencies could all help to increase access to free full text.


Asunto(s)
Fisioterapeutas , Modalidades de Fisioterapia , Brasil , Bases de Datos Factuales , Humanos , PubMed
17.
Artículo en Inglés | MEDLINE | ID: mdl-34574421

RESUMEN

Periodic repolarization dynamics (PRD) is a novel electrocardiographic marker of cardiac repolarization instability with powerful risk stratification capacity for total mortality and sudden cardiac death. Here, we use a time-frequency analysis approach to continuously quantify PRD at rest and during exercise, assess its dependence on heart rate variability (HRV) and characterize the effects of age (young adults/middle-aged adults/older adults), body mass index (non-overweight/overweight) and cardiorespiratory fitness level (fit/unfit). Sixty-six male volunteers performed an exercise test. RR and dT variabilities (RRV, dTV), as well as the fraction of dT variability unrelated to RR variability, were computed based on time-frequency representations. The instantaneous LF power of dT (PdTV), representing the same concept as PRD, and of its RRV-unrelated component (PdTVuRRV) were quantified. dT angle was found to mostly oscillate in the LF band. Overall, 50-70% of PdTV was linearly unrelated to RRV. The onset of exercise caused a sudden increase in PdTV and PdTVuRRV, which returned to pre-exercise levels during recovery. Clustering analysis identified a group of overweight and unfit individuals with significantly higher PdTV and PdTVuRRV values at rest than the rest of the population. Our findings shed new light on the temporal profile of PRD during exercise, its relationship to HRV and the differences in PRD between subjects according to phenotypic characteristics.


Asunto(s)
Electrocardiografía , Ejercicio Físico , Anciano , Prueba de Esfuerzo , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
18.
J Pers Med ; 11(12)2021 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-34945732

RESUMEN

This study focuses on the application of a non-immersive virtual reality (VR)-based neurocognitive intervention in critically ill patients. Our aim was to assess the feasibility of direct outcome measures to detect the impact of this digital therapy on patients' cognitive and emotional outcomes. Seventy-two mechanically ventilated adult patients were randomly assigned to the "treatment as usual" (TAU, n = 38) or the "early neurocognitive stimulation" (ENRIC, n = 34) groups. All patients received standard intensive care unit (ICU) care. Patients in the ENRIC group also received adjuvant neurocognitive stimulation during the ICU stay. Outcome measures were a full neuropsychological battery and two mental health questionnaires. A total of 42 patients (21 ENRIC) completed assessment one month after ICU discharge, and 24 (10 ENRIC) one year later. At one-month follow-up, ENRIC patients had better working memory scores (p = 0.009, d = 0.363) and showed up to 50% less non-specific anxiety (11.8% vs. 21.1%) and depression (5.9% vs. 10.5%) than TAU patients. A general linear model of repeated measures reported a main effect of group, but not of time or group-time interaction, on working memory, with ENRIC patients outperforming TAU patients (p = 0.008, ηp2 = 0.282). Our results suggest that non-immersive VR-based neurocognitive stimulation may help improve short-term working memory outcomes in survivors of critical illness. Moreover, this advantage could be maintained in the long term. An efficacy trial in a larger sample of participants is feasible and must be conducted.

19.
Sci Rep ; 11(1): 16014, 2021 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-34362950

RESUMEN

The ideal moment to withdraw respiratory supply of patients under Mechanical Ventilation at Intensive Care Units (ICU), is not easy to be determined for clinicians. Although the Spontaneous Breathing Trial (SBT) provides a measure of the patients' readiness, there is still around 15-20% of predictive failure rate. This work is a proof of concept focused on adding new value to the prediction of the weaning outcome. Heart Rate Variability (HRV) and Cardiopulmonary Coupling (CPC) methods are evaluated as new complementary estimates to assess weaning readiness. The CPC is related to how the mechanisms regulating respiration and cardiac pumping are working simultaneously, and it is defined from HRV in combination with respiratory information. Three different techniques are used to estimate the CPC, including Time-Frequency Coherence, Dynamic Mutual Information and Orthogonal Subspace Projections. The cohort study includes 22 patients in pressure support ventilation, ready to undergo the SBT, analysed in the 24 h previous to the SBT. Of these, 13 had a successful weaning and 9 failed the SBT or needed reintubation -being both considered as failed weaning. Results illustrate that traditional variables such as heart rate, respiratory frequency, and the parameters derived from HRV do not differ in patients with successful or failed weaning. Results revealed that HRV parameters can vary considerably depending on the time at which they are measured. This fact could be attributed to circadian rhythms, having a strong influence on HRV values. On the contrary, significant statistical differences are found in the proposed CPC parameters when comparing the values of the two groups, and throughout the whole recordings. In addition, differences are greater at night, probably because patients with failed weaning might be experiencing more respiratory episodes, e.g. apneas during the night, which is directly related to a reduced respiratory sinus arrhythmia. Therefore, results suggest that the traditional measures could be used in combination with the proposed CPC biomarkers to improve weaning readiness.


Asunto(s)
Frecuencia Cardíaca , Unidades de Cuidados Intensivos/estadística & datos numéricos , Respiración Artificial/métodos , Respiración , Desconexión del Ventilador/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
20.
IEEE Trans Biomed Eng ; 67(1): 193-202, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-30990416

RESUMEN

OBJECTIVE: Electrocardiogram (ECG) has been regarded as a source of respiratory information with the main focus in the estimation of the respiratory rate. Although little research concerning the estimation of tidal volume (TV) has been conducted, there are several ECG-derived features that have been related with TV in the literature, such as ECG-derived respiration, heart rate variability, and respiratory rate. In this paper, we exploited these features for estimating TV using a linear model. METHODS: 25 young (33.4 ± 5.2 years) healthy male volunteers were recruited for performing a maximal (MaxT) and a submaximal (SubT) treadmill stress test, which were conducted on different days. Both tests were automatically segmented in stages attending to the heart rate. Afterwards, a subject-specific TV model was calibrated for each stage, employing features from MaxT, and the model was later used for estimating the TV in SubT. RESULTS: During exercise, the different proposed approaches led to relative fitting errors lower than 14% in most of the cases and 6% in some of them. CONCLUSION: Low achieved fitting errors suggest that TV can be estimated from ECG during a treadmill stress test. SIGNIFICANCE: The results suggest that it is possible to estimate TV during exercise using only ECG-derived features.


Asunto(s)
Electrocardiografía/métodos , Prueba de Esfuerzo/métodos , Procesamiento de Señales Asistido por Computador , Volumen de Ventilación Pulmonar/fisiología , Adulto , Frecuencia Cardíaca/fisiología , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA