Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Eur Heart J Case Rep ; 8(4): ytae160, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38887779

RESUMEN

Background: Desmoplakin cardiomyopathy has been recently classified as a non-dilated left ventricular cardiomyopathy, which is characterized by inflammatory-like episodes followed by left ventricular fibrosis/dysfunction and ventricular arrhythmias. Specific management is unclear. Case summary: We report a detailed case of a 46-year-old Caucasian woman presenting with repeated sudden cardiac arrests who was diagnosed with a new variant in the desmoplakin gene. Because the initial 18F-fluorodeoxyglucose positron emission tomography scan showed significant hypermetabolism, she was treated with immunosuppressors, with only minimal improvement on imaging. Discussion: Desmoplakin cardiomyopathy should be considered in the differential diagnosis of inflammatory cardiomyopathies. Little is known about the use of immunosuppressive treatments, but it could be reasonable for some selected patients.

2.
Radiol Case Rep ; 18(8): 2738-2743, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37304318

RESUMEN

Phosphaturic mesenchymal tumor is a rare tumor characterized by paraneoplastic osteomalacia. The diagnosis is often delayed because of nonspecific symptoms and difficulty to localize the tumor. In this study we report a case of PMT of the left femur detected by Ga-68-DOTATATE PET-CT with radiological features mimicking osteoid osteoma. We report a 31-year-old female patient who presented to our hospital for evaluation due to progressive bone pain and muscle weakness. Her laboratory data showed hypophosphatemia and increased fibroblast growth factor 23 (FGF-23) together with reduced bone mineral density on bone densitometry. The diagnosis of PMT was suspected and the tumor was identified on Ga-68-DOTATATE PET-CT as a focal uptake in a lucent lesion of the left femoral head with a central sclerotic dot mimicking a nidus as seen in osteoid osteoma. The lesion was treated with percutaneous radiofrequency ablation. Laboratory tests and bone densitometry rapidly improved post-treatment. The present case emphasizes the difficulty to diagnose PMT due to its nonspecific biochemical and clinical presentation and the relevance of functional imaging for locating these tumors despite different radiological presentation.

3.
Magn Reson Imaging Clin N Am ; 31(4): 613-624, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37741645

RESUMEN

In the last few years, technological advances in MR imaging, PET detectors, and attenuation correction algorithms have allowed the creation of truly integrated PET/MR imaging systems, for both clinical and research applications. These machines allow a comprehensive investigation of cardiovascular diseases, by offering a wide variety of detailed anatomical and functional data in combination. Despite significant pathophysiologic mechanisms being clarified by this new data, its clinical relevance and prognostic significance have not been demonstrated yet.


Asunto(s)
Relevancia Clínica , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones
4.
Clin Nucl Med ; 48(12): 1035-1046, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37883015

RESUMEN

PURPOSE: Medical imaging artifacts compromise image quality and quantitative analysis and might confound interpretation and misguide clinical decision-making. The present work envisions and demonstrates a new paradigm PET image Quality Assurance NETwork (PET-QA-NET) in which various image artifacts are detected and disentangled from images without prior knowledge of a standard of reference or ground truth for routine PET image quality assurance. METHODS: The network was trained and evaluated using training/validation/testing data sets consisting of 669/100/100 artifact-free oncological 18 F-FDG PET/CT images and subsequently fine-tuned and evaluated on 384 (20% for fine-tuning) scans from 8 different PET centers. The developed DL model was quantitatively assessed using various image quality metrics calculated for 22 volumes of interest defined on each scan. In addition, 200 additional 18 F-FDG PET/CT scans (this time with artifacts), generated using both CT-based attenuation and scatter correction (routine PET) and PET-QA-NET, were blindly evaluated by 2 nuclear medicine physicians for the presence of artifacts, diagnostic confidence, image quality, and the number of lesions detected in different body regions. RESULTS: Across the volumes of interest of 100 patients, SUV MAE values of 0.13 ± 0.04, 0.24 ± 0.1, and 0.21 ± 0.06 were reached for SUV mean , SUV max , and SUV peak , respectively (no statistically significant difference). Qualitative assessment showed a general trend of improved image quality and diagnostic confidence and reduced image artifacts for PET-QA-NET compared with routine CT-based attenuation and scatter correction. CONCLUSION: We developed a highly effective and reliable quality assurance tool that can be embedded routinely to detect and correct for 18 F-FDG PET image artifacts in clinical setting with notably improved PET image quality and quantitative capabilities.


Asunto(s)
Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Inteligencia Artificial , Artefactos , Tomografía de Emisión de Positrones/métodos , Procesamiento de Imagen Asistido por Computador/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA