Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Opt Express ; 28(3): 4010-4020, 2020 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-32122061

RESUMEN

A silicon nitride micro-ring resonator with a loaded Q factor of 1.4 × 106 at 780 nm wavelength is demonstrated on silicon substrates. This is due to the low propagation loss waveguides achieved by optimization of waveguide sidewall interactions and top cladding refractive index. Potential applications include laser frequency stabilization allowing for chip-scale atomic systems targeting the 87Rb atomic transition at 780.24 nm. The temperature dependent wavelength shift of the micro-ring was determined to be 13.1 pm/K indicating that a minimum temperature stability of less than ±15 mK is required for such devices for wavelength locking applications. If a polyurethane acrylate top cladding of an optimized thickness is used then the micro-ring could effectively be athermal, resulting in reduced footprint, power consumption, and cost of potential devices.

2.
Phys Rev Lett ; 120(14): 141102, 2018 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-29694109

RESUMEN

We propose an upgrade to Advanced LIGO (aLIGO), named LIGO-LF, that focuses on improving the sensitivity in the 5-30 Hz low-frequency band, and we explore the upgrade's astrophysical applications. We present a comprehensive study of the detector's technical noises and show that with technologies currently under development, such as interferometrically sensed seismometers and balanced-homodyne readout, LIGO-LF can reach the fundamental limits set by quantum and thermal noises down to 5 Hz. These technologies are also directly applicable to the future generation of detectors. We go on to consider this upgrade's implications for the astrophysical output of an aLIGO-like detector. A single LIGO-LF can detect mergers of stellar-mass black holes (BHs) out to a redshift of z≃6 and would be sensitive to intermediate-mass black holes up to 2000 M_{⊙}. The detection rate of merging BHs will increase by a factor of 18 compared to aLIGO. Additionally, for a given source the chirp mass and total mass can be constrained 2 times better than aLIGO and the effective spin 3-5 times better than aLIGO. Furthermore, LIGO-LF enables the localization of coalescing binary neutron stars with an uncertainty solid angle 10 times smaller than that of aLIGO at 30 Hz and 4 times smaller when the entire signal is used. LIGO-LF also significantly enhances the probability of detecting other astrophysical phenomena including the tidal excitation of neutron star r modes and the gravitational memory effects.

3.
Philos Trans A Math Phys Eng Sci ; 376(2120)2018 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-29661979

RESUMEN

A microelectromechanical system (MEMS) gravimeter has been manufactured with a sensitivity of 40 ppb in an integration time of 1 s. This sensor has been used to measure the Earth tides: the elastic deformation of the globe due to tidal forces. No such measurement has been demonstrated before now with a MEMS gravimeter. Since this measurement, the gravimeter has been miniaturized and tested in the field. Measurements of the free-air and Bouguer effects have been demonstrated by monitoring the change in gravitational acceleration measured while going up and down a lift shaft of 20.7 m, and up and down a local hill of 275 m. These tests demonstrate that the device has the potential to be a useful field-portable instrument. The development of an even smaller device is underway, with a total package size similar to that of a smartphone.This article is part of a discussion meeting issue 'The promises of gravitational-wave astronomy'.

4.
Opt Express ; 23(12): 15380-9, 2015 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-26193518

RESUMEN

The absorption of light in transmissive optics cause a thermally induced effect known as thermal lensing. This effect provokes an often undesired change of a laser beam transmitted by the optic. In this paper we present a measurement method that allows us to determine thermal lensing in commonly used optical components. The beam influenced by the thermal lens is expanded into the eigenmodes of an optical cavity, and its modal content is analyzed in the eigenbasis of the cavity. The measured quantity depends neither on beam parameters nor on the position of the optical component under investigation. This method allows, to our knowledge, for the first time the direct measurement of the mode conversion coefficient |ε(2)| of the thermal lens.

5.
Opt Express ; 19(16): 14955-63, 2011 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-21934857

RESUMEN

We report on the first demonstration of a fully suspended 10 m Fabry-Perot cavity incorporating a waveguide grating as the coupling mirror. The cavity was kept on resonance by reading out the length fluctuations via the Pound-Drever-Hall method and employing feedback to the laser frequency. From the achieved finesse of 790 the grating reflectivity was determined to exceed 99.2% at the laser wavelength of 1064 nm, which is in good agreement with rigorous simulations. Our waveguide grating design was based on tantala and fused silica and included a ≈ 20 nm thin etch stop layer made of Al2O3 that allowed us to define the grating depth accurately and preserve the waveguide thickness during the fabrication process. Demonstrating stable operation of a waveguide grating featuring high reflectivity in a suspended low-noise cavity, our work paves the way for the potential application of waveguide gratings as mirrors in high-precision interferometry, for instance in future gravitational wave observatories.

6.
Light Sci Appl ; 7: 11, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30839613

RESUMEN

The recent discovery of gravitational waves (GW) by Advanced LIGO (Laser Interferometric Gravitational-wave Observatory) has impressively launched the novel field of gravitational astronomy and allowed us to glimpse exciting objects about which we could previously only speculate. Further sensitivity improvements at the low-frequency end of the detection band of future GW observatories must rely on quantum non-demolition (QND) methods to suppress fundamental quantum fluctuations of the light fields used to readout the GW signal. Here we present a novel concept of how to turn a conventional Michelson interferometer into a QND speed-meter interferometer with coherently suppressed quantum back-action noise. We use two orthogonal polarizations of light and an optical circulator to couple them. We carry out a detailed analysis of how imperfections and optical loss influence the achievable sensitivity. We find that the proposed configuration significantly enhances the low-frequency sensitivity and increases the observable event rate of binary black-hole coalescences in the range of 1 0 2 - 1 0 3 M ⊙ by a factor of up to ~300.

7.
J Mod Opt ; 61(sup1): S10-S45, 2014 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-25705087

RESUMEN

We present a review of modern optical techniques being used and developed for the field of gravitational wave detection. We describe the current state-of-the-art of gravitational waves detector technologies with regard to optical layouts, suspensions and test masses. We discuss the dominant sources and noise in each of these subsystems and the developments that will help mitigate them for future generations of detectors. We very briefly summarise some of the novel astrophysics that will be possible with these upgraded detectors.

8.
Appl Opt ; 45(28): 7269-72, 2006 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-16983413

RESUMEN

Low-absorption optics made of OH-reduced fused silica are a key technology for future gravitational wave detectors such as the Advanced LIGO. We developed a sensitive method to measure the absorption inside the beam splitter of the GEO 600, taking advantage of the effect of thermal lensing. Using this method, we derived a bulk absorption of less than 0.25 ppm/cm for a piece of Suprasil 311 SV at a wavelength of 1064 nm. To the best of our knowledge, this is the lowest value of light absorption inside fused silica reported so far in the literature.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA