Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.443
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Brief Bioinform ; 25(5)2024 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-39226887

RESUMEN

Plasma protein biomarkers have been considered promising tools for diagnosing dementia subtypes due to their low variability, cost-effectiveness, and minimal invasiveness in diagnostic procedures. Machine learning (ML) methods have been applied to enhance accuracy of the biomarker discovery. However, previous ML-based studies often overlook interactions between proteins, which are crucial in complex disorders like dementia. While protein-protein interactions (PPIs) have been used in network models, these models often fail to fully capture the diverse properties of PPIs due to their local awareness. This drawback increases the chance of neglecting critical components and magnifying the impact of noisy interactions. In this study, we propose a novel graph-based ML model for dementia subtype diagnosis, the graph propagational network (GPN). By propagating the independent effect of plasma proteins on PPI network, the GPN extracts the globally interactive effects between proteins. Experimental results showed that the interactive effect between proteins yielded to further clarify the differences between dementia subtype groups and contributed to the performance improvement where the GPN outperformed existing methods by 10.4% on average.


Asunto(s)
Biomarcadores , Proteínas Sanguíneas , Demencia , Aprendizaje Automático , Mapas de Interacción de Proteínas , Humanos , Demencia/metabolismo , Demencia/diagnóstico , Proteínas Sanguíneas/metabolismo , Mapeo de Interacción de Proteínas/métodos , Algoritmos , Biología Computacional/métodos
2.
J Am Chem Soc ; 146(1): 646-659, 2024 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-38151051

RESUMEN

Among the various metal-organic framework (MOF) adsorbents, diamine-functionalized Mg2(dobpdc) (dobpdc4- = 4,4-dioxidobiphenyl-3,3'-dicarboxylate) shows remarkable carbon dioxide removal performance. However, applying diamine-functionalized Mg2(dobpdc) in practical applications is premature because it shows persistent performance degradation under real flue gas conditions containing water vapor owing to diamine loss during wet cycles. To address this issue, we employed hydrophobic carbonate compounds to protect diamine groups in een-Mg2(dobpdc) (een-MOF, een = N-ethylethylenediamine). tert-Butyl dicarbonate (Boc) reacted rapidly with diamines at the pore openings of MOF particles to form dense secondary and tertiary hydrophobic amines, effectively preventing moisture ingress. The Boc-protected een-MOF-Boc1 maintained excellent CO2 adsorption even under simulated flue gas conditions containing 10% H2O. This observation indicates that Boc protection renders een groups intact during repeated wet cycles, suggesting that Boc-protected een groups are resistant to replacement by water molecules. To increase the practicability of the MOF adsorbent, we fabricated een-MOF/PAN-Boc1 composite beads by shaping MOF particles with polyacrylonitrile (PAN). Notably, the composite beads maintained their CO2 adsorption performance even after repeating the temperature swing adsorption process more than 150 times in 10% water vapor. Furthermore, breakthrough tests showed that the dynamic CO2 separation performance was retained under humid conditions. These results demonstrate that Boc protection provides an easy and effective way to develop promising adsorbents with high CO2 adsorption capacity, long-term durability, and the properties required for postcombustion applications.

3.
J Am Chem Soc ; 146(28): 19337-19349, 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-38953459

RESUMEN

Direct air capture (DAC) shows considerable promise for the effective removal of CO2; however, materials applicable to DAC are lacking. Among metal-organic framework (MOF) adsorbents, diamine-Mg2(dobpdc) (dobpdc4- = 4,4-dioxidobiphenyl-3,3'-dicarboxylate) effectively removes low-pressure CO2, but the synthesis of the organic ligand requires high temperature, high pressure, and a toxic solvent. Besides, it is necessary to isolate the ligand for utilization in the synthesis of the framework. In this study, we synthesized a new variant of extended MOF-74-type frameworks, M2(hob) (M = Mg2+, Co2+, Ni2+, and Zn2+; hob4- = 5,5'-(hydrazine-1,2-diylidenebis(methanylylidene))bis(2-oxidobenzoate)), constructed from an azine-bonded organic ligand obtained through a facile condensation reaction at room temperature. Functionalization of Mg2(hob) with N-methylethylenediamine, N-ethylethylenediamine, and N,N'-dimethylethylenediamine (mmen) enables strong interactions with low-pressure CO2, resulting in top-tier adsorption capacities of 2.60, 2.49, and 2.91 mmol g-1 at 400 ppm of CO2, respectively. Under humid conditions, the CO2 capacity was higher than under dry conditions due to the presence of water molecules that aid in the formation of bicarbonate species. A composite material combining mmen-Mg2(hob) and polyvinylidene fluoride, a hydrophobic polymer, retained its excellent adsorption performance even after 7 days of exposure to 40% relative humidity. In addition, the one-pot synthesis of Mg2(hob) from a mixture of the corresponding monomers is achieved without separate ligand synthesis steps; thus, this framework is suitable for facile large-scale production. This work underscores that the newly synthesized Mg2(hob) and its composites demonstrate significant potential for DAC applications.

4.
J Transl Med ; 22(1): 650, 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38997780

RESUMEN

BACKGROUND: Although the inherited risk factors associated with fatty liver disease are well understood, little is known about the genetic background of metabolic dysfunction-associated steatotic liver disease (MASLD) and its related health impacts. Compared to non-alcoholic fatty liver disease (NAFLD), MASLD presents significantly distinct diagnostic criteria, and epidemiological and clinical features, but the related genetic variants are yet to be investigated. Therefore, we conducted this study to assess the genetic background of MASLD and interactions between MASLD-related genetic variants and metabolism-related outcomes. METHODS: Participants from the UK Biobank were grouped into discovery and replication cohorts for an MASLD genome-wide association study (GWAS), and base and target cohorts for polygenic risk score (PRS) analysis. Autosomal genetic variants associated with NAFLD were compared with the MASLD GWAS results. Kaplan-Meier and Cox regression analyses were used to assess associations between MASLD and metabolism-related outcomes. RESULTS: Sixteen single-nucleotide polymorphisms (SNPs) were identified at genome-wide significance levels for MASLD and duplicated in the replication cohort. Differences were found after comparing these SNPs with the results of NAFLD-related genetic variants. MASLD cases with high PRS had a multivariate-adjusted hazard ratio of 3.15 (95% confidence interval, 2.54-3.90) for severe liver disease (SLD), and 2.81 (2.60-3.03) for type 2 diabetes mellitus. The high PRS amplified the impact of MASLD on SLD and extrahepatic outcomes. CONCLUSIONS: High PRS of MASLD GWAS amplified the impact of MASLD on SLD and metabolism-related outcomes, thereby refining the process of identification of individuals at high risk of MASLD. Supplementation of this process with relevant genetic backgrounds may lead to more effective MASLD prevention and management.


Asunto(s)
Predisposición Genética a la Enfermedad , Estudio de Asociación del Genoma Completo , Herencia Multifactorial , Polimorfismo de Nucleótido Simple , Humanos , Polimorfismo de Nucleótido Simple/genética , Masculino , Femenino , Herencia Multifactorial/genética , Factores de Riesgo , Persona de Mediana Edad , Hígado Graso/genética , Hígado Graso/complicaciones , Enfermedad del Hígado Graso no Alcohólico/genética , Enfermedades Metabólicas/genética , Enfermedades Metabólicas/complicaciones , Estudios de Cohortes , Estimación de Kaplan-Meier , Anciano , Modelos de Riesgos Proporcionales , Puntuación de Riesgo Genético
5.
Clin Endocrinol (Oxf) ; 100(2): 116-123, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38146598

RESUMEN

OBJECTIVE: Metabolic dysfunction-associated steatotic liver disease (MASLD) affects many populations, and screening out the high-risk populations at an early stage is a challenge. As a sarcopenia index, the relationship between creatinine to cystatin C ratio (CCR) and MASLD remains unclear. This cross-sectional, prospective study aimed to explore the relationship between CCR and MASLD. Design Firstly, explored the correlation between CCR and MASLD in cross-sectional analyses. Then excluded the population with baseeline diagnosis of MASLD and analyzed the association with baseline CCR levels and the onset of MASLD in the population with available follow-up data. Univariate and multivariate logistic regression analyses were used to calculate odds ratios (ORs) to evaluate the association between CCR levels and MASLD. PATIENTS AND MEASUREMENTS: This study included 368,634 participants from the UK Biobank for cross-sectional and prospective analyses. The demographic characteristics and laboratory measurements of all participants were obtained from the UK Biobank. MASLD was diagnosed according to the multi-society consensus nomenclature. Hepatic steatosis was defined as FLI  ≥60. RESULTS: We grouped the study participants according to CCR tertiles. In cross-sectional analyses, participants in CCR tertile 1 had the highest MASLD risk (OR: 1.070, 95% CI: 1.053-1.088, p < .001). And the similar association was observed in the prospective analyses (CCR tertile 1 OR: 1.340, 95% CI: 1.077-1.660, p = .009; CCR tertile 2 OR: 1.217, 95% CI: 1.021-1.450, p = .029, respectively). After stratification by gender, the significant association between CCR and the onset of MASLD was only observed in males (CCR tertile 1 OR: 1.639, 95% CI: 1.160-2.317, p = .005; CCR tertile 2 OR: 1.322, 95% CI: 1.073-1.628, p = .005, respectively). CONCLUSION: Our results indicated that lower CCR was significantly associated with higher risk of MASLD, based on which predictive models can be developed to screen populations at high risk of developing MASLD.


Asunto(s)
Cistatina C , Hígado Graso , Masculino , Humanos , Estudios Prospectivos , Creatinina , Estudios Transversales , Bancos de Muestras Biológicas , Biobanco del Reino Unido
6.
Osteoporos Int ; 35(4): 679-689, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38221591

RESUMEN

Previously observational studies did not draw a clear conclusion on the association between fatty liver diseases and bone mineral density (BMD). Our large-scale studies revealed that MAFLD and hepatic steatosis had no causal effect on BMD, while some metabolic factors were correlated with BMD. The findings have important implications for the relationship between fatty liver diseases and BMD, and may help direct the clinical management of MAFLD patients who experience osteoporosis and osteopenia. PURPOSE: Liver and bone are active endocrine organs with several metabolic functions. However, the link between metabolic dysfunction-associated fatty liver disease (MAFLD) and bone mineral density (BMD) is contradictory. METHODS: Using the UK Biobank and National Health and Nutrition Examination Survey (NHANES) dataset, we investigated the association between MAFLD, steatosis, and BMD in the observational analysis. We performed genome-wide association analysis to identify single-nucleotide polymorphisms associated with MAFLD. Large-scale two-sample Mendelian randomization (TSMR) analyses examined the potential causal relationship between MAFLD, hepatic steatosis, or major comorbid metabolic factors, and BMD. RESULTS: After adjusting for demographic factors and body mass index, logistic regression analysis demonstrated a significant association between MAFLD and reduced heel BMD. However, this association disappeared after adjusting for additional metabolic factors. MAFLD was not associated with total body, femur neck, and lumbar BMD in the NHANES dataset. Magnetic resonance imaging-measured steatosis did not show significant associations with reduced total body, femur neck, and lumbar BMD in multivariate analysis. TSMR analyses indicated that MAFLD and hepatic steatosis were not associated with BMD. Among all MAFLD-related comorbid factors, overweight and type 2 diabetes showed a causal relationship with increased BMD, while waist circumference and hyperlipidemia had the opposite effect. CONCLUSION: No causal effect of MAFLD and hepatic steatosis on BMD was observed in this study, while some metabolic factors were correlated with BMD. This has important implications for understanding the relationship between fatty liver disease and BMD, which may help direct the clinical management of MAFLD patients with osteoporosis.


Asunto(s)
Diabetes Mellitus Tipo 2 , Diagnóstico por Imagen de Elasticidad , Enfermedad del Hígado Graso no Alcohólico , Osteoporosis , Humanos , Densidad Ósea/genética , Estudio de Asociación del Genoma Completo , Análisis de la Aleatorización Mendeliana , Encuestas Nutricionales , Osteoporosis/genética
7.
BMC Cancer ; 24(1): 246, 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38388861

RESUMEN

BACKGROUND: Artificial intelligence (AI)-assisted clinical trial screening is a promising prospect, although previous matching systems were developed in English, and relevant studies have only been conducted in Western countries. Therefore, we evaluated an AI-based clinical trial matching system (CTMS) that extracts medical data from the electronic health record system and matches them to clinical trials automatically. METHODS: This study included 1,053 consecutive inpatients primarily diagnosed with hepatocellular carcinoma who were referred to the liver tumor center of an academic medical center in China between January and December 2019. The eligibility criteria extracted from two clinical trials, patient attributes, and gold standard were decided manually. We evaluated the performance of the CTMS against the established gold standard by measuring the accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and run time required. RESULTS: The manual reviewers demonstrated acceptable interrater reliability (Cohen's kappa 0.65-0.88). The performance results for the CTMS were as follows: accuracy, 92.9-98.0%; sensitivity, 51.9-83.5%; specificity, 99.0-99.1%; PPV, 75.7-85.1%; and NPV, 97.4-98.9%. The time required for eligibility determination by the CTMS and manual reviewers was 2 and 150 h, respectively. CONCLUSIONS: We found that the CTMS is particularly reliable in excluding ineligible patients in a significantly reduced amount of time. The CTMS excluded ineligible patients for clinical trials with good performance, reducing 98.7% of the work time. Thus, such AI-based systems with natural language processing and machine learning have potential utility in Chinese clinical trials.


Asunto(s)
Inteligencia Artificial , Carcinoma Hepatocelular , Neoplasias Hepáticas , Selección de Paciente , Humanos , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/terapia , China/epidemiología , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/terapia , Reproducibilidad de los Resultados , Estudios Retrospectivos , Ensayos Clínicos como Asunto , Hospitalización
8.
Purinergic Signal ; 2024 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-39066830

RESUMEN

Immunosuppression is a hallmark of cancer progression. Tumor-derived small extracellular vesicles (sEV), also known as TEX, produce adenosine (ADO) and can mediate tumor-induced immunosuppression.Here, the ATP pathway of ADO production (ATP →  ADP →  AMP →  ADO) by ecto-nucleotidases carried on the sEV surface was evaluated by a method using N6-etheno-ATP (eATP) and N6-etheno-AMP (eAMP) as substrates for enzymatic activity. The "downstream" N6-etheno-purines (ePurines) were measured by high performance liquid chromatography with fluorescence detection (HPLC-FL).Human melanoma cell-derived TEX (MTEX) metabolized eATP to N6-etheno-ADP (eADP), eAMP and N6-etheno-Adenosine (eADO) more robustly than control keratinocyte cell-derived sEV (CEX); due to accelerated conversion of eATP to eADP and eADP to eAMP. MTEX and CEX similarly metabolized eAMP to eADO. Blocking of the ATP pathway with the selective CD39 inhibitor ARL67156 or pan ecto-nucleotidase inhibitor POM-1 normalized the ATP pathway but neither inhibitor completely abolished it. In contrast, inhibition of CD73 by PSB12379 or AMPCP abolished eADO formation by both MTEX and CEX, suggesting that targeting CD73 is the preferred approach to eliminating ADO produced by ecto-nucleotidases located on the sEV surface.The noninvasive, sensitive, and specific assay assessing ePurine metabolism ± ecto-nucleotidase inhibitors in TEX enables the personalized identification of ecto-nucleotidase activity primarily involved in ADO production in patients with cancer. The assay could guide precision medicine by determining which purine is the preferred target for inhibitory therapeutic interventions.

9.
J Clin Periodontol ; 51(1): 24-32, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37872750

RESUMEN

AIM: To compare the implant accuracy, safety and morbidity between robot-assisted and freehand dental implant placement. MATERIALS AND METHODS: Subjects requiring single-site dental implant placement were recruited. Patients were randomly allocated to freehand implant placement and robot-assisted implant placement. Differences in positional accuracy of the implant, surgical morbidity and complications were assessed. The significance of intergroup differences was tested with an intention-to-treat analysis and a per-protocol (PP) analysis (excluding one patient due to calibration error). RESULTS: Twenty patients (with a median age of 37, 13 female) were included. One subject assigned to the robotic arm was excluded from the PP analysis because of a large calibration error due to the dislodgement of the index. For robot-assisted and freehand implant placement, with the PP analysis, the median (25th-75th percentile) platform global deviation, apex global deviation and angular deviation were 1.23 (0.9-1.4) mm/1.9 (1.2-2.3) mm (p = .03, the Mann-Whitney U-test), 1.40 (1.1-1.6) mm/2.1 (1.7-3.9) mm (p < .01) and 3.0 (0.9-6.0)°/6.7 (2.2-13.9)° (p = .08), respectively. Both methods showed limited damage to the alveolar ridge and had similar peri- and post-operative morbidity and safety. CONCLUSIONS: Robot-assisted implant placement enabled greater positional accuracy of the implant compared to freehand placement in this pilot trial. The robotic system should be further developed to simplify surgical procedures and improve accuracy and be validated in properly sized trials assessing the full spectrum of relevant outcomes.


Asunto(s)
Implantes Dentales , Robótica , Cirugía Asistida por Computador , Humanos , Femenino , Proyectos Piloto , Tecnología Háptica , Implantación Dental Endoósea/métodos , Tomografía Computarizada de Haz Cónico , Diseño Asistido por Computadora
10.
Clin Oral Implants Res ; 35(6): 598-608, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38517053

RESUMEN

OBJECTIVES: To systematically analyze the accuracy of robotic surgery for dental implant placement. MATERIALS AND METHODS: PubMed, Embase, and Cochrane CENTRAL were searched on October 25, 2023. Model studies or clinical studies reporting the accuracy of robotic surgery for dental implant placement among patients with missing or hopeless teeth were included. Risks of bias in clinical studies were assessed. Meta-analyses were undertaken. RESULTS: Data from 8 clinical studies reporting on 109 patients and 242 implants and 13 preclinical studies were included. Positional accuracy was measured by comparing the implant plan in presurgery CBCT and the actual implant position in postsurgery CBCT. For clinical studies, the pooled (95% confidence interval) platform deviation, apex deviation, and angular deviation were 0.68 (0.57, 0.79) mm, 0.67 (0.58, 0.75) mm, and 1.69 (1.25, 2.12)°, respectively. There was no statistically significant difference between the accuracy of implants placed in partially or fully edentulous patients. For model studies, the pooled platform deviation, apex deviation, and angular deviation were 0.72 (0.58, 0.86) mm, 0.90 (0.74, 1.06) mm, and 1.46 (1.22, 1.70)°, respectively. No adverse event was reported. CONCLUSION: Within the limitation of the present systematic review, robotic surgery for dental implant placement showed suitable implant positional accuracy and had no reported obvious harm. Both robotic systems and clinical studies on robotic surgery for dental implant placement should be further developed.


Asunto(s)
Implantación Dental Endoósea , Implantes Dentales , Procedimientos Quirúrgicos Robotizados , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Implantación Dental Endoósea/métodos , Tomografía Computarizada de Haz Cónico
11.
Artículo en Inglés | MEDLINE | ID: mdl-39233386

RESUMEN

OBJECTIVES: This study aimed to compare the accuracy of digital complete-arch implant impressions with prefabricated aids using three intraoral scanners (IOSs) and explore the correlation between virtual deviation measurement and physical framework misfit. MATERIALS AND METHODS: Four edentulous maxillary master models with four and six parallel and angular implants were fabricated and scanned by a laboratory scanner as reference scans. Ten scans of each master model were acquired using three IOSs (IOS-T, IOS-M, and IOS-A) with and without prefabricated aids. Trueness and precision of root mean square (RMS) errors were measured. Ten aluminum alloy frameworks were fabricated, and the misfit was measured with a micro-computed tomography scan with one screw tightened. RESULTS: Trueness and precision showed significant improvement when prefabricated aids were used for all three IOSs (p < 0.010). Median (interquartile range) RMS errors of trueness reduced from 67.5 (30.4) to 61.8 (30.3) µm, from 100.6 (35.4) to 45.9 (15.1) µm, and from 52.7 (33.2) to 41.1 (22.5) µm for scanner IOS-T, IOS-M, and IOS-A, respectively (p < 0.010). The precision of IOS-A and IOS-M was significantly better than IOS-T when using prefabricated aid (p < 0.001). RMS errors and the maximum marginal misfit of the framework were significantly correlated (p < 0.001, R2 = 0.845). CONCLUSIONS: With the prefabricated aids, the accuracy of IOSs enhanced significantly in digital complete-arch implant impressions. Three IOSs showed different levels of improvement in accuracy. Virtual RMS errors <62.2 µm could be the clinically acceptable threshold (150 µm) for framework passive fit.

12.
Eur Spine J ; 33(7): 2611-2620, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38819738

RESUMEN

PURPOSE: The minimally invasive oblique lumbar interbody fusion (MI-OLIF) L5-S1 was introduced to overcome the limitations of conventional fusion techniques, however, MI-OLIF is not possible using the standard method due to vascular structures in some cases. We aimed to introduce the "lateral corridor" and report the details of the surgical technique with a clinical case series. METHODS: We utilized the lateral access route of the left common iliac vein and named it the "lateral corridor", to distinguish the technique from the standard technique (central corridor). The type and frequency of branch vessels that required additional manipulations were reviewed, and the frequency of intraoperative vascular injury was investigated. RESULTS: Among the 107 patients who underwent MI-OLIF L5-S1, 26 patients (24.3%) who received the "lateral corridor" technique were included. Branch vessel ligation was required in 42.3% of the patients. The types of branch vessels that required ligation were seven cases (26.9%) of the iliolumbar vein (ILV) and six cases (23.1%) of ascending lumbar vein (ALV). The ILV and ALV were ligated in two cases. None of the patients developed intraoperative vascular injuries. CONCLUSION: We introduced the "lateral corridor" as an alternative approach for MI-OLIF L5-S1, implemented it in 24.3% of the patient cohort, and reported favorable outcomes devoid of vascular complications. The "lateral corridor" necessitated ligation of the ILV or ALV in 42.3% of cases. The "lateral corridor" approach appears to be a promising surgical technique, offering feasibility even in instances where the vascular anatomy precludes the employment of the conventional approach.


Asunto(s)
Vértebras Lumbares , Procedimientos Quirúrgicos Mínimamente Invasivos , Fusión Vertebral , Humanos , Fusión Vertebral/métodos , Masculino , Femenino , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Vértebras Lumbares/cirugía , Persona de Mediana Edad , Anciano , Adulto , Sacro/cirugía
13.
Environ Toxicol ; 39(6): 3473-3480, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38450827

RESUMEN

Cholelithiasis is a common digestive disease that drives a myriad of adverse complications. The correlation between sarcopenia and various digestive disorders has been extensively researched, whereas its association with cholelithiasis remains unreported. We aimed to investigate the association through prospective and Mendelian randomization (MR) analyses and establish a quantitative score reflecting the impact of sarcopenia-related markers on cholelithiasis. The prospective study involved 448 627 participants from the UK Biobank. Cox proportional hazard models were employed to investigate the correlation between sarcopenia-related markers and cholelithiasis. To quantitatively assess cholelithiasis risk, the SARCHO score was derived from a multivariable Cox model. Bidirectional two-sample MR analysis was conducted to validate the causal association. A total of 16 738 individuals developed cholelithiasis during a median follow-up of 12 years. Hazard ratios (HRs) of cholelithiasis decreased stepwise over skeletal muscle index tertiles (highest tertile: reference; middle tertile: 1.23, p < .001; lowest tertile: 1.33, p < .001). The tertiles of grip strength showed a similar pattern. Individuals with slow walking pace had a higher risk of cholelithiasis compared to those with normal walking pace (HR 1.23; p < .001). Our SARCHO score better quantifies the risk of cholelithiasis. MR analysis showed a causal relationship between muscle mass and cholelithiasis (OR 0.81; p < .001). No causal effect of cholelithiasis on lean mass was observed. Prospective and MR analyses have consistently demonstrated an increased risk of cholelithiasis in individuals with decreased muscle mass. Additionally, SARCHO score further quantified the cholelithiasis occurrence risk. These findings provide compelling evidence for muscle strengthening in preventing cholelithiasis.


Asunto(s)
Colelitiasis , Análisis de la Aleatorización Mendeliana , Sarcopenia , Humanos , Sarcopenia/epidemiología , Colelitiasis/epidemiología , Estudios Prospectivos , Femenino , Masculino , Persona de Mediana Edad , Biomarcadores/sangre , Anciano , Adulto , Modelos de Riesgos Proporcionales , Factores de Riesgo
14.
Sensors (Basel) ; 24(3)2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38339435

RESUMEN

Needle electromyogram (EMG) research has suggested that endplate noise (EPN) is a characteristic of myofascial trigger points (MTrPs). Although several studies have observed MTrPs through ultrasonography, whether they are hyperechoic or hypoechoic in ultrasound images is still controversial. Therefore, this study determined the echogenicity of MTrP ultrasonography. In stage 1, the MTrP of rat masseter muscle was identified through palpation and marked. Needle EMG was performed to detect the presence of EPN. When EPN was detected, ultrasound scans and indwelling needles were used to identify the nodule with a different grayscale relative to that of its surrounding tissue, and the echogenicity of the identified MTrP was determined. In stage 2, these steps were reversed. An ultrasound scan was performed to detect the nodule at the marked site, and an EMG needle was inserted into the nodule to detect EPN. There were 178 recordings in each stage, obtained from 45 rats. The stage 1 results indicate that the MTrPs in ultrasound images were hypoechoic with a 100% sensitivity of assessment. In stage 2, the accuracy and precision of MTrP detection through ultrasonography were 89.9% and 89.2%, respectively. The results indicate that ultrasonography produces highly accurate and precise MTrP detection results.


Asunto(s)
Síndromes del Dolor Miofascial , Puntos Disparadores , Ratas , Animales , Síndromes del Dolor Miofascial/diagnóstico por imagen , Ultrasonografía , Electromiografía , Agujas
15.
Alzheimers Dement ; 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-39001624

RESUMEN

INTRODUCTION: This study aimed to explore the potential of whole brain white matter patterns as novel neuroimaging biomarkers for assessing cognitive impairment and disability in older adults. METHODS: We conducted an in-depth analysis of magnetic resonance imaging (MRI) and amyloid positron emission tomography (PET) scans in 454 participants, focusing on white matter patterns and white matter inter-subject variability (WM-ISV). RESULTS: The white matter pattern ensemble model, combining MRI and amyloid PET, demonstrated a significantly higher classification performance for cognitive impairment and disability. Participants with Alzheimer's disease (AD) exhibited higher WM-ISV than participants with subjective cognitive decline, mild cognitive impairment, and vascular dementia. Furthermore, WM-ISV correlated significantly with blood-based biomarkers (such as glial fibrillary acidic protein and phosphorylated tau-217 [p-tau217]), and cognitive function and disability scores. DISCUSSION: Our results suggest that white matter pattern analysis has significant potential as an adjunct neuroimaging biomarker for clinical decision-making and determining cognitive impairment and disability. HIGHLIGHTS: The ensemble model combined both magnetic resonance imaging (MRI) and amyloid positron emission tomography (PET) and demonstrated a significantly higher classification performance for cognitive impairment and disability. Alzheimer's disease (AD) revealed a notably higher heterogeneity compared to that in subjective cognitive decline, mild cognitive impairment, or vascular dementia. White matter inter-subject variability (WM-ISV) was significantly correlated with blood-based biomarkers (glial fibrillary acidic protein and phosphorylated tau-217 [p-tau217]) and with the polygenic risk score for AD. White matter pattern analysis has significant potential as an adjunct neuroimaging biomarker for clinical decision-making processes and determining cognitive impairment and disability.

16.
Int J Mol Sci ; 25(15)2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39126027

RESUMEN

Korean mistletoe (Viscum album L. var. coloratum) is renowned for its medicinal properties, including anti-cancer and immunoadjuvant effects. This study aimed to elucidate the mechanisms by which Korean mistletoe lectin (V. album L. var. coloratum agglutinin; VCA) modulates breast cancer cell apoptosis and macrophage polarization. The specific objectives were to (1) investigate the direct effects of VCA on MCF-7 breast cancer cells and THP-1-derived M1/M2 macrophages; (2) analyze the impact of VCA on the paracrine interactions between these cell types; and (3) compare the efficacy of VCA in 2D vs. 3D co-culture models to bridge the gap between in vitro and in vivo studies. We employed both 2D and 3D models, co-culturing human M1/M2 macrophages with human MCF-7 breast cancer cells in a Transwell system. Our research demonstrated that M1 and M2 macrophages significantly influenced the immune and apoptotic responses of breast cancer cells when exposed to VCA. M1 macrophages exhibited cytotoxic characteristics and enhanced VCA-induced apoptosis in both 2D and 3D co-culture models. Conversely, M2 macrophages initially displayed a protective effect by reducing apoptosis in breast cancer cells, but this protective effect was reversed upon exposure to VCA. Furthermore, our findings illustrate VCA's ability to modulate M1 and M2 polarization in breast cancer cells. Finally, the use of magnetic 3D cell cultures suggests their potential to yield results comparable to conventional 2D cultures, bridging the gap between in vitro and in vivo studies.


Asunto(s)
Apoptosis , Neoplasias de la Mama , Técnicas de Cocultivo , Macrófagos , Humanos , Apoptosis/efectos de los fármacos , Macrófagos/efectos de los fármacos , Macrófagos/metabolismo , Neoplasias de la Mama/patología , Neoplasias de la Mama/metabolismo , Neoplasias de la Mama/tratamiento farmacológico , Células MCF-7 , Femenino , Viscum album/química , Lectinas de Plantas/farmacología , Células THP-1
17.
J Prosthet Dent ; 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38991886

RESUMEN

STATEMENT OF PROBLEM: Conventional impression techniques for complete arch implant-supported fixed dental prostheses (CIFDPs) are technique sensitive. Stereophotogrammetry (SPG) and intraoral scanning (IOS) may offer alternatives to conventional impression making. PURPOSE: The purpose of this in vitro study was to assess the accuracy and passive fit of IOS with prefabricated aids, SPG, and open tray impression (OI) for CIFDPs with different implant distributions. MATERIAL AND METHODS: Three definitive casts with 4 parallel implants (4-PARA), 4 inclined implants (4-INCL), and 6 parallel implants (6-PARA) were fabricated. Three recording techniques were tested: IOS with prefabricated aids, SPG, and OI. The best and the worst scans were selected to fabricate 18 milled aluminum alloy frameworks. The trueness and precision of distance deviation (∆td and ∆pd), angular deviation (∆tθand ∆pθ), root mean square errors (∆tRMS for ∆pRMS), and passive fit score of frameworks were recorded. Two-way ANOVA was applied. RESULTS: SPG showed the best trueness and precision (95%CI of ∆td/∆tθ/∆tRMS, 31 to 39 µm, 0.22 to 0.28 degrees, 20 to 23 µm; 95%CI of ∆pd/∆pθ/∆pRMS, 9 to 11 µm, 0.06 to 0.08 degrees, 8 to 10 µm), followed by OI (61 to 83 µm, 0.33 to 0.48 degrees, 28 to 48 µm; 66 to 81 µm, 0.29 to 0.38 degrees, 32 to 41 µm) and IOS (143 to 193 µm, 0.37 to 0.50 degrees, 81 to 96 µm; 89 to 111 µm, 0.27 to 0.31 degrees, 51 to 62 µm). Tilted implants were associated with increased distance deviation. Increased implant number was associated with improved recording precision. The passive fit of frameworks was negatively correlated with the RMS error, and the correlation coefficient was -0.65 (P=.003). CONCLUSIONS: SPG had the best accuracy. Implant distributions affected implant precision. The RMS error can be used to evaluate the passive fit of frameworks.

18.
J Neuroradiol ; 51(1): 59-65, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37247754

RESUMEN

PURPOSE: In the endovascular era, postcoiling recanalization of cerebral aneurysms is occurring with greater frequency. Repeat coiling is usually done to prevent rebleeding, although long-term outcomes of re-embolization have yet to be adequately investigated. The present study was undertaken to assess clinical and radiographic outcomes of re-embolization in recanalized aneurysms, focusing on procedural safety, efficacy, and durability. METHOD: In this retrospective review, we examined 308 patients with 310 recurrent aneurysms. All lesions were re-coiled, once major recanalization (after initial coil embolization) was established. Medical records and radiologic data amassed during extended follow-up were then subject to review. Cox proportional hazards regression analysis was undertaken to identify risk factors for subsequent recurrence. RESULT: During a lengthy follow-up (mean, 40.2 ± 33.0 months), major recanalization developed again in 87 aneurysms (28.1%). Multivariable Cox regression analysis linked re-recanalization to initial saccular neck width (p=.003) and autosomal dominant polycystic kidney disease (ADPKD; p<.001). Stent implantation (p=.038) and successful occlusion at second coiling (p=.012) were protective against later recanalization in this setting. The more recent the second embolization was performed, the lower the risk of further recurrence (p=.023). Procedure-related complications included asymptomatic thromboembolism (n = 9), transient ischemic neurologic deficits (n = 2), procedural bleeding (n = 1), and coil migration (n = 1), but there were no residual effects or deaths. CONCLUSION: Repeat coil embolization is a safe therapeutic option for recanalized cerebral aneurysms. Wide-necked status and ADPKD emerged as risks for subsequent recanalization, whereas successful occlusion and stent implantation seemed to reduce the likelihood of recurrence after re-embolization procedures.


Asunto(s)
Embolización Terapéutica , Aneurisma Intracraneal , Riñón Poliquístico Autosómico Dominante , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Aneurisma Intracraneal/etiología , Resultado del Tratamiento , Estudios de Seguimiento , Riñón Poliquístico Autosómico Dominante/etiología , Riñón Poliquístico Autosómico Dominante/terapia , Angiografía Cerebral , Stents , Embolización Terapéutica/métodos , Estudios Retrospectivos
19.
Angew Chem Int Ed Engl ; 63(21): e202400855, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38503692

RESUMEN

Postsynthetic modifications (PSMs) of metal-organic frameworks (MOFs) play a crucial role in enhancing material performance through open metal site (OMS) functionalization or ligand exchange. However, a significant challenge persists in preserving open metal sites during ligand exchange, as these sites are inherently bound by incoming ligands. In this study, for the first time, we introduced alkoxides by exchanging bridging chloride in Ni2Cl2BTDD (BTDD=bis (1H-1,2,3,-triazolo [4,5-b],-[4',5'-i]) dibenzo[1,4]dioxin) through PSM. Rietveld refinement of synchrotron X-ray diffraction data indicated that the alkoxide oxygen atom bridges Ni(II) centers while the OMSs of the MOF are preserved. Due to the synergy of the existing OMS and introduced functional group, the alkoxide-exchanged MOFs showed CO2 uptakes superior to the pristine MOF. Remarkably, the tert-butoxide-substituted Ni_T exhibited a nearly threefold and twofold increase in CO2 uptake compared to Ni2Cl2BTDD at 0.15 and 1 bar, respectively, as well as high water stability relative to the other exchanged frameworks. Furthermore, the Grand Canonical Monte Carlo simulations for Ni_T suggested that CO2 interacts with the OMS and the surrounding methyl groups of tert-butoxide groups, which is responsible for the enhanced CO2 capacity. This work provides a facile and unique synthetic strategy for realizing a desirable OMS-incorporating MOF platform through bridging ligand exchange.

20.
Physiol Genomics ; 55(2): 90-100, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36645668

RESUMEN

Bone marrow mesenchymal stem cells (BMSCs) exert pivotal roles in suppressing immune rejection in organ transplantation. However, the function of BMSCs on immune rejection in renal transplantation remains unclear. This study aimed to evaluate the effect and underlying mechanism of BMSCs on immune rejection in renal transplantation. Following the establishment of the renal allograft mouse model, the isolated primary BMSCs were injected intravenously into the recipient mice. Enzyme-linked immunosorbent assay, flow cytometry, hematoxylin-eosin staining, and Western blot assays were conducted to investigate BMSCs' function in vivo and in vitro. Mechanistically, the underlying mechanism of BMSCs on immune rejection in renal transplantation was investigated in in vivo and in vitro models. Functionally, BMSCs alleviated the immune rejection in renal transplantation mice and facilitated B cell activation and the production of IL-10+ regulatory B cells (Bregs). Furthermore, the results of mechanism studies revealed that BMSCs induced the production of IL-10+ Bregs by facilitating a proliferation-inducing ligand (APRIL) phosphorylation to enhance immunosuppression and repressed renal transplant rejection by promoting APRIL phosphorylation to induce IL-10+ Bregs. BMSCs prevent renal transplant rejection by facilitating APRIL phosphorylation to induce IL-10+ Bregs.


Asunto(s)
Linfocitos B Reguladores , Trasplante de Riñón , Trasplante de Células Madre Mesenquimatosas , Células Madre Mesenquimatosas , Ratones , Animales , Interleucina-10 , Rechazo de Injerto , Fosforilación , Trasplante de Células Madre Mesenquimatosas/métodos , Células de la Médula Ósea
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA