Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Eur J Neurol ; 24(7): 981-e38, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28557247

RESUMEN

BACKGROUND AND PURPOSE: To support clinical decision-making in central neurological disorders, a physical examination is used to assess responses to passive muscle stretch. However, what exactly is being assessed is expressed and interpreted in different ways. A clear diagnostic framework is lacking. Therefore, the aim was to arrive at unambiguous terminology about the concepts and measurement around pathophysiological neuromuscular response to passive muscle stretch. METHODS: During two consensus meetings, 37 experts from 12 European countries filled online questionnaires based on a Delphi approach, followed by plenary discussion after rounds. Consensus was reached for agreement ≥75%. RESULTS: The term hyper-resistance should be used to describe the phenomenon of impaired neuromuscular response during passive stretch, instead of for example 'spasticity' or 'hypertonia'. From there, it is essential to distinguish non-neural (tissue-related) from neural (central nervous system related) contributions to hyper-resistance. Tissue contributions are elasticity, viscosity and muscle shortening. Neural contributions are velocity dependent stretch hyperreflexia and non-velocity dependent involuntary background activation. The term 'spasticity' should only be used next to stretch hyperreflexia, and 'stiffness' next to passive tissue contributions. When joint angle, moment and electromyography are recorded, components of hyper-resistance within the framework can be quantitatively assessed. CONCLUSIONS: A conceptual framework of pathophysiological responses to passive muscle stretch is defined. This framework can be used in clinical assessment of hyper-resistance and will improve communication between clinicians. Components within the framework are defined by objective parameters from instrumented assessment. These parameters need experimental validation in order to develop treatment algorithms based on the aetiology of the clinical phenomena.


Asunto(s)
Examen Neurológico , Enfermedades Neuromusculares/diagnóstico , Consenso , Sistemas de Apoyo a Decisiones Clínicas , Técnica Delphi , Electromiografía , Europa (Continente) , Humanos , Espasticidad Muscular/diagnóstico , Espasticidad Muscular/fisiopatología , Músculo Esquelético/fisiopatología , Enfermedades Neuromusculares/fisiopatología , Terminología como Asunto
3.
Disabil Rehabil ; 43(19): 2769-2778, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-31999496

RESUMEN

PURPOSE: Existing physical activity interventions do not reach a considerable proportion of physically disabled people. This study assessed feasibility and short-term effects of Activity Coach+, a community-based intervention especially targeting this hard-to-reach population. METHODS: Feasibility was determined by reach, dropouts, and compliance with the protocol. Physical activity was measured with the Activ8 accelerometer and the adapted SQUASH questionnaire. Health outcomes were assessed by body composition, blood pressure, hand grip force, 10-metre walk test, 6-minute walk test, and the Berg Balance Scale. The RAND-36, Exercise Self-Efficacy Scale, Fatigue Severity Scale, and IMPACT-S were administered. Measurements were performed at baseline and after 2 and 4 months. Changes over time were analysed by Friedman tests. RESULTS: Twenty-nine participants enrolled during the first 4 months, of whom two dropped out. Intervention components were employed in 86-100% of the participants. Physical activity did not change after the implementation of Activity Coach+. Body mass index (p = 0.006), diastolic blood pressure (p = 0.032), walking ability (p = 0.002), exercise capacity (p = 0.013), balance (p = 0.014), and vitality (p = 0.049) changed over time. CONCLUSIONS: Activity Coach + is feasible in a community setting. Indications for effectivity of Activity Coach + in hard-to-reach people with a physical disability were found.Implications for rehabilitationActivity Coach + was able to reach physically disabled people living in community, a population that is assumed hard-to-reach.Activity Coach + was feasible in a population of persons with a physical disability that was heterogeneous with respect to age and (severity of) disability.The current study provides the first indications for the beneficial health effects of Activity Coach + in hard-to-reach people with a physical disability.


Asunto(s)
Personas con Discapacidad , Fuerza de la Mano , Ejercicio Físico , Estudios de Factibilidad , Humanos , Caminata
4.
Knee ; 29: 78-85, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33582594

RESUMEN

OBJECTIVES: Physical activity is promoted in patients with hip or knee osteoarthritis (OA), yet little is known about its relationship with symptoms, functional limitations and Quality of Life (QoL). We investigated if OA-associated pain, functional limitations and QoL are associated with objectively measured physical activity in patients with end-stage hip/knee OA. METHODS: Cross-sectional study including patients scheduled for primary total hip/knee arthroplasty. Patients wore an accelerometer (Activ8) with physical activity assessed over waking hours, and expressed as number of activity daily counts (ADC) per hour, %time spent on physical activity i.e. walking, cycling or running (%PA), and %time spent sedentary (%SB). Pain, functional limitations and joint-specific and general QoL were assessed with the Hip disability/Knee Injury and Osteoarthritis Outcome Score (HOOS/KOOS) and the Short Form (SF)-12. Multivariate linear regression models with the three to Z-scores transformed parameters of physical activity as dependent variables and adjusted for confounding, were conducted. RESULTS: 49 hip and 48 knee OA patients were included. In hip and knee OA patients the mean number of ADC, %PA and %SB were 18.79 ± 7.25 and 21.19 ± 6.16, 14 ± 6.4 and 15 ± 5.0, and 66 ± 10.5 and 68 ± 8.7, respectively. In hip OA, better joint-specific and general QoL were associated with more ADC, (ß 0.028; 95%CI:0.007-0.048, ß0.041; 95%CI:0.010-0.071). Also, better general QoL was associated with the %PA (ß 0.040, 95%CI:0.007-0.073). No other associations were found. CONCLUSION: Whereas QoL was associated with physical activity in hip OA, pain and functional limitations were not related to objectively measured physical activity in patients with end-stage hip or knee OA.


Asunto(s)
Artralgia/fisiopatología , Ejercicio Físico/fisiología , Osteoartritis de la Cadera/fisiopatología , Osteoartritis de la Rodilla/fisiopatología , Calidad de Vida , Acelerometría/instrumentación , Anciano , Estudios Transversales , Femenino , Humanos , Masculino , Dimensión del Dolor , Caminata/fisiología
5.
J Biomech ; 39(1): 110-8, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16271594

RESUMEN

Objective measurement of weight bearing during a long-term period can give insight into the postoperative loading of the lower extremity of orthopedic patients to avoid complications. This study investigated the validity of vertical ground reaction force measurements during a long-term period using the Pedar Mobile insole pressure system, by comparing it with a Kistler force platform. In addition, the validity of a new sensor drift correction algorithm to correct for offset drift in the Pedar signal was evaluated. Ground reaction force data were collected during dynamic and static conditions from five healthy subjects every hour for 7 h. A mean offset drift of 14.6% was found after 7 h. After applying the drift correction algorithm the Pedar system showed a high accuracy for the second peak in the ground reaction force-time curve (1.1 to 3.4% difference, p>0.05) and step duration (-2.0 to 4.4% difference, p>0.05). Less accuracy was found for the first peak in the ground reaction force-time curve (5.2 to 12.0% difference; p<0.05 for the first 3 h, p>0.05 for the last 4 h) and, consequently, in the vertical force impulse (5.5 to 11.0% difference, p>0.05). The Pedar Mobile system appeared to be a valid instrument to measure the vertical force during a long-term period when using the drift correction program described in this study.


Asunto(s)
Monitoreo Ambulatorio/instrumentación , Soporte de Peso , Adulto , Femenino , Humanos , Masculino , Zapatos , Programas Informáticos , Estrés Mecánico , Transductores de Presión
6.
Med Biol Eng Comput ; 43(2): 265-72, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15865138

RESUMEN

Piezoresistive accelerometer signals are frequently used in movement analysis. However, their use and interpretation are complicated by the fact that the signal is composed of different acceleration components. The aim of the study was to obtain insight into the components of accelerometer signals from the trunk and thigh segments during four different sit-to-stand (STS) movements (self-selected, slow, fast and fullflexion). Nine subjects performed at least six trials of each type of STS movement. Accelerometer signals from the trunk and thigh in the sagittal direction were decomposed using kinematic data obtained from an opto-electronic device. Each acceleration signal was decomposed into gravitational and inertial components, and the inertial component of the trunk was subsequently decomposed into rotational and translational components. The accelerometer signals could be reliably reconstructed: mean normalised root mean square (RMS) trunk: 6.5% (range 3-12%), mean RMS thigh: 3% (range 2-5%). The accelerometric signals were highly characteristic and repeatable. The influence of the inertial component was significant, especially on the timing of the specific event of maximum trunk flexion in the accelerometer signal. The effect of inertia was larger in the trunk signal than in the thigh signal and increased with higher speeds. The study provides insight into the acceleration signal, its components and the influence of the type of STS movement and supports its use in STS movement analysis.


Asunto(s)
Movimiento/fisiología , Postura/fisiología , Procesamiento de Señales Asistido por Computador , Aceleración , Adulto , Femenino , Humanos , Masculino , Muslo/fisiología
7.
Physiol Meas ; 35(11): 2297-306, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25340938

RESUMEN

This study assessed whether self-propelled wheelchair driving can be validly detected by a new method using a set of two commonly used accelerometers.In a rehabilitation centre, 10 wheelchair-bound persons with spinal cord injury (SCI) (aged 29-63 years) performed a series of representative daily activities according to a protocol including self-propelled wheelchair driving and other activities. Two ActiGraph GT3X+ accelerometers were used; one was attached at the wrist, the other to the spokes of the wheelchair wheel. Based on the movement intensity of the two accelerometers, a custom-made algorithm in MatLab differentiated between self-propelled wheelchair driving and other activities (e.g. being pushed or arm movements not related to wheelchair driving). Video recordings were used for reference. Validity scores between the accelerometer output and the video analyses were expressed in terms of agreement, sensitivity and specificity scores.Overall agreement for the detection of self-propelled wheelchair driving was 85%; sensitivity was 88% and specificity 83%. Disagreement between accelerometer output and video analysis was largest for wheelchair driving at very low speed on a treadmill, wheelchair driving on a slope on a treadmill, and being pushed in the wheelchair whilst making excessive arm movements.Valid detection of self-propelled wheelchair driving is provided by two accelerometers and a simple algorithm. Disagreement with the video analysis was largest during three atypical daily activities.


Asunto(s)
Acelerometría/métodos , Monitoreo Ambulatorio/métodos , Silla de Ruedas , Adulto , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Traumatismos de la Médula Espinal/rehabilitación
8.
Med Eng Phys ; 31(8): 937-44, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19523867

RESUMEN

Physical whole-body vibration (WBV) exercises become available at various levels of intensity. In a first series of measurements, we investigated 3-dimensional platform accelerations of three different WBV devices without and with three volunteers of different weight (62, 81 and 100 kg) in squat position (150 degrees knee flexion). The devices tested were two professional devices, the PowerPlate and the Galileo-Fitness, and one home-use device, the PowerMaxx. In a second series of measurements, the transmission of vertical platform accelerations of each device to the lower limbs was tested in eight healthy volunteers in squat position (100 degrees knee flexion). The first series showed that the platforms of two professional devices vibrated in an almost perfect vertical sine wave at frequencies between 25-50 and 5-40 Hz, respectively. The platform accelerations were slightly influenced by body weight. The PowerMaxx platform mainly vibrated in the horizontal plane at frequencies between 22 and 32 Hz, with minimal accelerations in the vertical direction. The weight of the volunteers reduced the platform accelerations in the horizontal plane but amplified those in the vertical direction about eight times. The vertical accelerations were highest in the Galileo (approximately 15 units of g) and the PowerPlate (approximately 8 units of g) and lowest in the PowerMaxx (approximately 2 units of g). The second series showed that the transmission of vertical accelerations at a common preset vibration frequency of 25 Hz were largest in the ankle and that transmission of acceleration reduced approximately 10 times at the knee and hip. We conclude that large variation in 3-dimensional accelerations exist in commercially available devices. The results suggest that these differences in mechanical behaviour induce variations in transmissibility of vertical vibrations to the (lower) body.


Asunto(s)
Aceleración , Terapia por Ejercicio/instrumentación , Extremidad Inferior/fisiopatología , Vibración , Adulto , Terapia por Ejercicio/métodos , Humanos , Fenómenos Mecánicos , Postura , Soporte de Peso
9.
J Neurol Neurosurg Psychiatry ; 74(12): 1655-61, 2003 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-14638885

RESUMEN

OBJECTIVES: To investigate the effect of pyridostigmine on fatigue, physical performance, and muscle function in subjects with postpoliomyelitis syndrome. METHODS: 67 subjects with increased fatigue and new weakness in one quadriceps muscle showing neuromuscular transmission defects, were included in a randomised, double blind, placebo controlled trial of 60 mg pyridostigmine four times a day for 14 weeks. Primary outcome was fatigue (on the "energy" category of the Nottingham health profile). Secondary outcomes included two minute walking distance and quadriceps strength and jitter. Motor unit size of the quadriceps was studied as a potential effect modifier. The primary data analysis compared the changes from baseline in the outcomes in the last week of treatment between groups. RESULTS: 31 subjects treated with pyridostigmine and 31 subjects treated with placebo completed the trial. No significant effect of pyridostigmine was found on fatigue. The walking distance improved more in the pyridostigmine group than in the placebo group (by 7.2 m (6.0%); p<0.01). Subgroup analysis showed that a significant improvement in walking performance was only found in subjects with normal sized motor units. Quadriceps strength improved more in the pyridostigmine group than in the placebo group (by 6.7 Nm (7.2%); p = 0.15). No effect of pyridostigmine was found on jitter. CONCLUSIONS: Pyridostigmine in the prescribed dose did not reduce fatigue in subjects with postpoliomyelitis syndrome. However, it may have a limited beneficial effect on physical performance, especially in subjects with neuromuscular transmission defects in normal sized motor units.


Asunto(s)
Inhibidores de la Colinesterasa/uso terapéutico , Tolerancia al Ejercicio/efectos de los fármacos , Fatiga Muscular/efectos de los fármacos , Síndrome Pospoliomielitis/tratamiento farmacológico , Desempeño Psicomotor/efectos de los fármacos , Bromuro de Piridostigmina/uso terapéutico , Adulto , Método Doble Ciego , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Síndrome Pospoliomielitis/fisiopatología , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA