Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 92
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Artif Organs ; 27(1): 32-40, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36991242

RESUMEN

Mosaic valve shows higher pressure gradient after aortic valve replacement compared to other same size labeled prostheses in postoperative echocardiogram. The purpose of this study was to evaluate the mid-term echocardiogram findings and long-term clinical outcomes of patients receiving a 19 mm Mosaic. Forty-six aortic stenosis patients receiving 19 mm Mosaic and 112 patients receiving either 19 mm Magna or Inspiris, who underwent mid-term follow-up echocardiogram were included in the study. Mid-term hemodynamic measurements evaluated by trans-thoracic echocardiogram and long-term outcomes were compared. Patients receiving Mosaic were significantly older (Mosaic: 76 ± 5.1 years vs. Magna/Inspiris: 74 ± 5.5 years, p = 0.046) and had smaller body surface area (Mosaic: 1.40 ± 0.114m2 vs. Magna/Inspiris: 1.48 ± 0.143m2, p < 0.001). There were no significant differences in comorbidities and medications. Post-operative echocardiogram performed at 1 week after the surgery showed higher maximum pressure gradient in patients receiving Mosaic (Mosaic: 38 ± 13.5 mmHg vs. Magna/Inspiris: 31 ± 10.7 mmHg, p = 0.002). Furthermore, mid-term echocardiogram follow-up performed at median duration of 53 ± 14.9 months after the surgery continuously showed higher maximum pressure gradient in patients receiving Mosaic (Mosaic: 45 ± 15.6 mmHg vs. Magna/Inspiris: 32 ± 13.0 mmHg, p < 0.001). However, there were no significant difference in changes in left ventricular mass from baseline in both groups. Kaplan-Meyer curve also showed no difference in long-term mortality and major adverse cardiac and cerebrovascular event between the two groups. Although the pressure gradient across the valve evaluated by echocardiogram was higher in 19 mm Mosaic compared to 19 mm Magna/Inspiris, there were no significant differences in left ventricular remodeling and long-term outcomes between the two groups.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Remodelación Ventricular , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Hemodinámica , Resultado del Tratamiento , Diseño de Prótesis
2.
J Artif Organs ; 27(1): 23-31, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36738330

RESUMEN

OBJECTIVES: The purpose of this study was to evaluate the effect of decalcification and existence of stent at the aortic annulus on mitral annular motion after surgery. METHODS: Patients receiving Inspiris (Edwards, CA, USA, n = 117), Intuity (Edwards, n = 36), Perceval (Corcym, London, UK, n = 36), Evolut (Medtronics, MN, USA, n = 81) and Sapien 3 (Edwards, n = 250) were included in the study. Mitral annular motion was evaluated by E', using tissue doppler imaging. RESULTS: After surgery, a significant increase in E' was observed in patients receiving Inspiris (Before: 4.2 ± 1.21 cm/s vs. Discharge: 5.0 ± 1.23 cm/s, p < 0.001). Mid-term echocardiogram performed at 11.8 ± 2.2 months after the surgery, showed a significant increase in E' in patients receiving Inspiris (Before: 4.2 ± 1.21 cm/s vs. Mid-term: 5.2 ± 1.20 cm/s, p < 0.001) and Perceval (Before: 3.9 ± 1.34 cm/s vs. Mid-term: 4.5 ± 1.24 cm/s, p = 0.008). Univariable analysis showed a higher increase in E' in patients with decalcified annulus compared to those without decalcified annulus (Decalcification: 0.15 ± 1.321 cm/s vs. No Decalcification: 0.66 ± 1.420 cm/s, p < 0.001). Multivariable analysis showed that balloon-expandable stent (ß = - 0.6960, p < 0.001) and self-expanding stent (r = - 0.3592, p = 0.042) were independent limiting factors for an increase in E' at discharge. However, balloon-expandable stent (ß = - 0.8382, p < 0.001), and not self-expanding stent (ß = - 0.3682, p = 0.089), was a remaining independent factor associated with E' at mid-term follow-up. CONCLUSIONS: Decalcification was associated with improvement in E' after surgery. Balloon-expandable stent was an independent limiting factor for improvement in E' up to 1 year after the surgery, while self-expanding stent was not a significant factor after 1 year.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Stents , Resultado del Tratamiento , Diseño de Prótesis
3.
Kyobu Geka ; 77(8): 607-612, 2024 Aug.
Artículo en Japonés | MEDLINE | ID: mdl-39205416

RESUMEN

Malignant cardiac tumor is a rare tumor with extremely poor prognosis, and metastatic cardiac tumor causes superior vena cava( SVC) syndrome. A 52-year-old man visited a clinic with a chief complaint of facial edema. Contrast-enhanced computed tomography( CT) revealed a mass in the right atrium( RA)obstructing the SVC. Echocardiography revealed a mass about to incarcerate the tricuspid valve orifice. The patient was transferred to our institution for emergency surgery. Tumor resection was performed under general anesthesia. A cardiopulmonary bypass was established with cannulate in the ascending aorta, in the RA through the right femoral vein, and in the left ventricle for venting. The RA was incised, and the tumor was resected. The SVC was incised, and the tumor and blood clots were removed. Because adhesion between vessel wall and the mass was tight, complete mass removal and recanalization of the SVC was not attempted. Pathological diagnosis was metastatic squamous cell carcinoma. All imaging studies failed to identify primary lesions. The clinical course was uneventful, and the patient was discharged on postoperative day 17. Four months postoperatively, chemotherapy for squamous cell carcinoma was initiated. The patient is alive at approximately 28 months postoperatively.


Asunto(s)
Neoplasias Cardíacas , Síndrome de la Vena Cava Superior , Humanos , Síndrome de la Vena Cava Superior/etiología , Síndrome de la Vena Cava Superior/cirugía , Síndrome de la Vena Cava Superior/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Neoplasias Cardíacas/secundario , Neoplasias Cardíacas/cirugía , Neoplasias Cardíacas/complicaciones , Neoplasias Cardíacas/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Carcinoma de Células Escamosas/cirugía , Carcinoma de Células Escamosas/complicaciones , Carcinoma de Células Escamosas/secundario
4.
Kyobu Geka ; 76(11): 924-927, 2023 Oct.
Artículo en Japonés | MEDLINE | ID: mdl-38056949

RESUMEN

A 44-year old man with a history of Stanford type B acute aortic dissection was admitted for the treatment of acute aortic dissection. Computed tomography( CT) scan showed a descending entry-type non-A non-B aortic dissection with a maximum diameter of 65 mm occurring in a patient with Edwards typeⅢ right aortic arch whose left subclavian artery was obliterated. The patient was initially treated conservatively and underwent one-stage extended aortic repair from the ascending aorta to the descending thoracic aorta via median sternotomy 22 days after the symptom onset. Although the patient suffered from right empyema postoperatively, he was discharged from the hospital on postoperative day 64 after 4 weeks antibiotics therapy. The patient was also complicated by right recurrent nerve palsy, hoarseness improved over the 8 months after surgery.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Masculino , Humanos , Adulto , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Disección Aórtica/complicaciones , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aorta/cirugía , Procedimientos Quirúrgicos Vasculares , Esternotomía , Stents , Aneurisma de la Aorta Torácica/complicaciones , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Resultado del Tratamiento
5.
J Artif Organs ; 25(2): 132-139, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34665354

RESUMEN

Negative impact of prosthesis-patient mismatch on long-term survival after valve replacement has been reported. However, the effect of prosthesis-patient mismatch after bioprosthetic mitral valve replacement has not yet been well examined. The purpose of this study was to investigate the effect of prosthesis-patient mismatch on late outcomes after bioprosthetic mitral valve replacement for mitral regurgitation. A total of 181 patients underwent bioprosthetic mitral valve replacement between April 2008 and December 2016. After excluding patients with mitral stenosis and those with incomplete data, 128 patients were included in the study. Postoperative transthoracic echocardiography was performed before discharge for all patients and the effective orifice area of bioprosthetic mitral valve was calculated using the formula: 220/pressure half-time, and the effective orifice area index was calculated by the formula: effective orifice area/body surface area. Prosthesis-patient mismatch was defined as a postoperative effective orifice area index ≤ 1.2 cm2/m2. The characteristics and outcomes were compared between the groups. There were 34 patients (26.6%) with prosthesis-patient mismatch and 94 patients (73.4%) without prosthesis-patient mismatch. There were no significant differences in the in-hospital mortality and morbidities. Multivariable analysis showed that prosthesis-patient mismatch was an independent predictor of late mortality (hazard ratio 3.38; 95% confidence interval 1.69-6.75; p = 0.001) and death from heart failure (hazard ratio 31.03, 95% confidence interval 4.49-214.40, p < 0.001). Prosthesis-patient mismatch at discharge after mitral valve replacement for mitral regurgitation was associated with long-term mortality and death from heart failure.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Aórtica/cirugía , Insuficiencia Cardíaca/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
6.
J Artif Organs ; 25(3): 238-244, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34727259

RESUMEN

Rapid deployment valve has expanded surgical indication for high-risk patients with aortic stenosis despite its accommodated risk for conduction disorder (CD). The purpose of this study was to evaluate the degree of oversizing in association with postoperative CD. During June 2019 to September 2021, 25 patients underwent aortic valve replacement with Edwards INTUITY. Device size selection was evaluated intraoperatively using provided sizers. Oversizing was evaluated retrospectively by measuring the difference of the dimension of the annulus and left ventricular outflow tract (LVOT) compared to the dimensions of the device used by preoperative-computed tomography. Although there was no incidence of pacemaker implantation, seven patients (28.0%) experienced CD after surgery. There was no difference in device area and annulus area (CD: - 37 ± 22.7 mm2 vs. no CD: - 56 ± 63.6 mm2, p = 0.47), and device circumference and annulus circumference (CD: - 4.4 ± 2.77 mm vs. no CD: - 6.9 ± 5.60 mm, p = 0.26) in patients with and without CD. However, there was a significant difference in area of the device skirt and sub-annular area at the LVOT (CD: 114 ± 28.4 mm2 vs. no CD: - 8 ± 80.0 mm2, p < 0.001), and circumference of device skirt and the LVOT (CD: 3.9 ± 2.08 mm vs. no CD: - 4.6 ± 5.24 mm, p < 0.001) between the two groups. Receiver operating characteristic curve analysis showed that an area difference of 77.7 mm2 and circumference difference of 0.91 mm at LVOT were associated with postoperative CD with specificities of 0.83, 0.78 and sensitivity of 1.0, 1.0, respectively. Preoperative measurement of the LVOT may be useful in evaluating the risk of postoperative CD in patients receiving rapid deployment valve.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/patología , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Prótesis Valvulares Cardíacas/clasificación , Prótesis Valvulares Cardíacas/normas , Humanos , Diseño de Prótesis , Curva ROC , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter , Resultado del Tratamiento
7.
J Card Surg ; 37(9): 2706-2712, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35726649

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the changes in mitral annular motion after surgery in patients with aortic stenosis. METHODS: Patients receiving Edwards (Edwards) valves were included in the study. Echocardiographic findings were compared among the three treatments postoperatively, at discharge, and at 1 year after the surgery. Mitral annular motion was evaluated by e prime, using tissue doppler imaging. RESULTS: There were 111 patients receiving Inspiris, 30 patients receiving Intuity and 241 patients receiving Sapien 3. The patients receiving Sapien 3 were significantly older, (Inspiris: 71 ± 6.7 years vs. Intuity: 75 ± 5.2 years vs. Sapien 3: 84 ± 5.1 years, p < .001), and prevalence of hemodialysis were significantly higher in patients receiving Intuity (Inspiris: 11.7% vs. Intuity: 46.7% vs. Sapien 3: 0.0%, p < .001). There was a significant improvement in mean pressure gradient in all groups (Inspiris: 55 ± 21.2-13 ± 5.2 mmHg, p < .001; Intuity: 48 ± 17.6-12 ± 4.9 mmHg, p < .001, Sapien 3: 55 ± 16.6-14 ± 5.2 mmHg, p < .001). Decalcification was associated with increase in e prime after surgery (no decalcification: 0.10 ± 1.280 cm/s vs. decalcification: 0.68 ± 1.405 cm/s, p < .001) Further, existence of stent was associated with less increase in e prime after surgery (no stent: 0.83 ± 1.210 cm/s vs. stent: 0.10 ± 1.356; p < .001). Multivariate analysis showed that existence of stent but not decalcification of the aortic valve was independently associated with changes in e prime after surgery (ß: -.4679, 95% confidence interval: -0.93389 to -0.00200, p = .049). CONCLUSIONS: Although improvement in pressure gradient was achieved in all treatments, existence of stent inhibited mitral annular motion after surgery.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Diseño de Prótesis , Resultado del Tratamiento
8.
Surg Today ; 52(3): 431-440, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34724105

RESUMEN

PURPOSE: We investigated factors contributing to coagulopathy in patients with acute type A aortic dissection (ATAAD) and coagulopathy's influence on patient outcomes. METHODS: We grouped 420 patients who underwent ATAAD repair-none under anticoagulation therapy or with liver disease-by the prothrombin time-international normalized ratio (PT-INR) at admission: < 1.2 (no coagulopathy, n = 371), 1.2-1.49 (mild coagulopathy, n = 33), or ≥ 1.5 (severe coagulopathy, n = 16). We then compared the clinical presentation, dissection morphology, and outcomes among the groups. We assessed the PT-INR in relation to the preoperative hemodynamics and searched for factors predictive of a PT-INR ≥ 1.2. RESULTS: The transfusion volume and operation time were increased among patients with coagulopathy (P < 0.05). The in-hospital mortality (15.2-37.5% vs. 5.1%, P < 0.001) and 5-year survival (61.1-74.4% vs. 87.6%) were relatively poor for these patients. The median PT-INR was 1.03 (0.97-1.1) for patients with stable hemodynamics (n = 318), 1.11 (1.02-1.21) for those in shock (blood pressure < 80 mmHg) not given cardiopulmonary resuscitation (CPR) (n = 81), and 1.1 (1.0-1.54) for those in shock given CPR (n = 21) (P < 0.001). A multivariable analysis identified shock (P < 0.001), a partially thrombosed false lumen (P = 0.006), and mesenteric malperfusion (P = 0.016) as predictive variables. CONCLUSIONS: Shock, a partially thrombosed false lumen, and mesenteric malperfusion appear to be predictive of dissection-related coagulopathy, which influences outcomes negatively.


Asunto(s)
Disección Aórtica , Trastornos de la Coagulación Sanguínea , Disección Aórtica/cirugía , Trastornos de la Coagulación Sanguínea/etiología , Humanos , Relación Normalizada Internacional , Tiempo de Protrombina , Estudios Retrospectivos , Resultado del Tratamiento
9.
Kyobu Geka ; 75(10): 775-780, 2022 Sep.
Artículo en Japonés | MEDLINE | ID: mdl-36155568

RESUMEN

Ventricular rupture after mitral valve surgery is rare but a serious complication associated with high mortality rate. Of the 2,338 patients who underwent mitral valve surgery, 8 patients (0.7%) suffered from left ventricular rupture in our institution. All developed left ventricular rupture after mitral valve replacement and 3 patients( 37.5%) died within 30 days. To prevent left ventricular rupture, preservation of the mitral loop, appropriate valve sizing, and perioperative hemodynamic management to unload ventricular pressure are needed. Surgical repair for left ventricular rupture should be performed under cardiac arrest. Combination of external approach and endoventricular repair is recommended but epicardial tissue sealing may be an only option for patients with friable ventricular muscles and undetermined location of ruptured site. Use of intraaortic balloon pumping (IABP), percutaneous cardiopulmonary support (PCPS) and Impella are also important technique to unload left ventricular pressure and to maintain systemic hemodynamics.


Asunto(s)
Rotura Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Rotura Cardíaca/diagnóstico por imagen , Rotura Cardíaca/etiología , Rotura Cardíaca/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Ventrículos Cardíacos/cirugía , Humanos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Rotura/etiología
10.
Artif Organs ; 45(4): 382-389, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33191501

RESUMEN

Hemodynamic management based on cerebral autoregulation range is a possible strategy for preserving major organ perfusion during cardiovascular surgery. The purpose of this study was to evaluate the relation of vascular properties with lower limit of cerebral autoregulation (LLA). LLA was monitored in 66 patients undergoing cardiovascular surgery using near-infrared spectroscopy. To determine the clinical importance of LLA monitoring, association of blood pressure excursions below LLA and acute kidney injury (AKI) was evaluated. Flow-mediated dilation (FMD) and pulse wave velocity (PWV) were measured for the evaluation of endothelial function and aortic stiffness. Variables associated with LLA were evaluated. Excluding patients on hemodialysis, there were 15 patients (25.9%) who developed AKI. Blood pressure excursions below LLA were higher in patients who developed AKI (4.55 mm Hg × hr vs. 1.23 mm Hg × hr, P = .017). In the univariate analysis, prevalence of ischemic heart disease (No IHD: 53 ± 13.0 mm Hg vs. IHD: 60.0 ± 13.6 mm Hg, P = .056) and FMD (r = -0.42, 95% CI -0.61 to -0.19, P < .001) were associated with LLA before cardiopulmonary bypass (CPB). During CPB, calcium channel blocker (No Ca blocker: 42 ± 10.6 mm Hg vs. Ca blocker: 49 ± 14.3 mm Hg, P = .033), diabetes (no DM: 44 ± 13.2 mm Hg vs. DM: 55 ± 10.0 mm Hg, P = .024), FMD (r = -0.32, 95% CI -0.55 to -0.05, P = .021), and PWV (r = 0.28, 95% CI 0.012 to 0.513, P = .041) were associated with LLA. Multivariate analysis showed that FMD was correlated with LLA before CPB (r = -2.19, 95% CI -3.621 to -0.755, P = .003), while PWV was correlated with LLA during CPB (r = 0.01, 95% CI 0.001-0.019, P = .023). Endothelial function and aortic stiffness may be important factors in determining LLA at different phases in cardiovascular surgery.


Asunto(s)
Puente Cardiopulmonar , Circulación Cerebrovascular/fisiología , Endotelio Vascular/fisiopatología , Homeostasis/fisiología , Rigidez Vascular , Lesión Renal Aguda/fisiopatología , Anciano , Femenino , Humanos , Masculino , Monitoreo Intraoperatorio , Espectroscopía Infrarroja Corta
11.
J Card Surg ; 36(4): 1557-1559, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33491196

RESUMEN

A 38-year-old man who was resuscitated from ventricular fibrillation was diagnosed with acute aortic dissection complicated by coronary malperfusion. He underwent total aortic arch replacement and coronary artery bypass grafting to the left anterior descending coronary artery. Due to low cardiac output syndrome from cardiac ischemia, central extracorporeal membrane oxygenator (ECMO) was established with aortic cannulation from the side branch of the implanted prosthetic graft and venous drainage from the femoral vein. Ventricular venting was added from the right upper pulmonary vein for the distended left ventricle. ECMO was weaned off on postoperative Day 4. The patient is back on his normal daily life for more than 1 year after the surgery.


Asunto(s)
Disección Aórtica , Oxigenación por Membrana Extracorpórea , Adulto , Gasto Cardíaco Bajo , Corazón , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Humanos , Masculino
12.
Kyobu Geka ; 74(10): 740-745, 2021 Sep.
Artículo en Japonés | MEDLINE | ID: mdl-34548439

RESUMEN

With increasing number of patients undergoing aortic valve replacement, many patients are at risk for redo aortic valve surgery. It has been reported that 56.2% of the patients receiving a bioprostheis and 7.4% of the patients receiving a mechanical valve need reoperation 20 years after the primary surgery. Although valve in valve transcatheter aortic valve implantation (TAVI) is a less invasive approach, redo aortic valve replacement is preferred for patients with prosthetic valve endocarditis, small aortic valve prosthesis and poor access for TAVI. Special care should be prepared for safe re-sternotomy, cardiopulmonary bypass management and strategy for cardioplegia. As reported from high volume centers, redo aortic valve replacement could be performed at a similar mortality rate as the primary surgery. New prostheses such as sutureless valve and rapid deployment valve could be useful, as well as minimally invasive cardiac surgery approach, which may prevent tissue injury. However, redo aortic valve replacement via re-sternotomy remains a gold standard. Techniques and strategy for redo aortic valve replacement are reviewed.


Asunto(s)
Estenosis de la Válvula Aórtica , Endocarditis Bacteriana , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
13.
Kyobu Geka ; 74(8): 583-586, 2021 Aug.
Artículo en Japonés | MEDLINE | ID: mdl-34334598

RESUMEN

A 26-year-old man with relapsing polychondritis was admitted for the treatment of multiple thoracic aortic aneurysms in the ascending and descending aorta. Descending thoracic aortic aneurysm showed rapid expansion, therefore, the patient underwent an extended thoracic aortic repair from the ascending aorta to the descending aorta via anterolateral thoracotomy and partial sternotomy. Although postoperative course was uneventful, aortic root enlargement and severe aortic insufficiency progressed over the next two years. He and his family refused redo surgical intervention and the patient died of heart failure. Careful perioperative follow-up may be mandatory in a patient with relapsing polychondritis complicated by cardiovascular disease.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Policondritis Recurrente , Adulto , Aorta/cirugía , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Humanos , Masculino , Policondritis Recurrente/complicaciones , Toracotomía
14.
Cell Physiol Biochem ; 54(5): 947-958, 2020 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-32975918

RESUMEN

BACKGROUND/AIMS: We recently described a novel regulatory role for histone deacetylase 2 (HDAC2) in protecting endothelial cells from oxidized low-density lipoprotein (OxLDL)-induced injury. In this study, we examined the effects of endothelial-specific HDAC2 overexpression on endothelial-dependent vasorelaxation and atherogenesis in vivo. METHODS: Endothelial-specific HDAC2-overexpressing transgenic mice (HDAC2-Tg) were generated under control of the Tie2 promoter. An atherosclerosis model was produced by injecting HDAC2-Tg and wild-type (WT) mice with adeno-associated virus encoding a PCSK9 gain-of-function mutant under control of a liver-specific promoter and feeding them a high-fat diet for 12 weeks. Aortic stiffness in vivo was determined by measuring pulse wave velocity. Wire myography was used to measure endothelium dependent (acetylcholine) and independent (sodium nitroprusside) relaxation in isolated mice aortas. Atherosclerotic plaque burden in aortas was determined by Oil Red O staining and protein expression was determined by western blotting. RESULTS: At baseline, HDAC2-Tg mice had normal mean arterial blood pressure (MAP) and body weight, but pulse wave velocity (PWV), an inverse measure of vascular health and stiffness, was decreased, suggesting that their vessels were more compliant. Moreover, basal nitric oxide production was enhanced in the vessels of HDAC2-Tg mice as compared to that in WT controls, although no significant differences in acetylcholine (endothelial component)- or sodium nitroprusside (non-endothelial component)-mediated relaxation were observed. However, after exposure to OxLDL, aortas from HDAC2-Tg mice exhibited greater acetylcholine-induced relaxation than did those from WT mice. Thus, endothelial-specific vasodilator production was enhanced despite oxidative injury. Atherosclerosis induction in WT mice led to a significant increase in PWV, but in HDAC2-Tg mice, PWV and MAP remained unchanged. Further, aortic rings from HDAC2-Tg exhibited better endothelial-dependent vascular relaxation than did those from WT mice, but not when treated with nitric oxide synthase inhibitor L-NAME. Finally, plaque burden, determined by Oil red O staining, was significantly increased in WT, but not HDAC2-Tg mice, subjected to the atherogenic model. Deletion of endothelial HDAC2 led to impaired endothelial cell-dependent vascular relaxation and increased PWV, compared with those in littermate controls. CONCLUSION: HDAC2 protects against endothelial dysfunction and atherogenesis induced by oxidized lipids. Hence, overexpression or activation of HDAC2 represents a novel therapy for endothelial dysfunction and atherosclerosis. HDAC2-Tg mice provide an opportunity to determine the role of endothelial HDAC2 in vascular endothelial homeostasis.


Asunto(s)
Aterosclerosis/enzimología , Histona Desacetilasa 2/biosíntesis , Animales , Aorta/metabolismo , Apolipoproteínas E/genética , Apolipoproteínas E/metabolismo , Aterosclerosis/metabolismo , Aterosclerosis/patología , Células Endoteliales/enzimología , Células Endoteliales/metabolismo , Endotelio/enzimología , Endotelio/metabolismo , Endotelio Vascular/metabolismo , Células HEK293 , Histona Desacetilasa 2/genética , Histona Desacetilasa 2/metabolismo , Humanos , Lipoproteínas LDL , Masculino , Ratones , Ratones Endogámicos C57BL , Ratones Transgénicos , Óxido Nítrico/metabolismo , Placa Aterosclerótica/metabolismo , Proproteína Convertasa 9/metabolismo , Análisis de la Onda del Pulso , Vasodilatación/efectos de los fármacos , Vasodilatadores/farmacología
15.
Circ J ; 84(12): 2312-2319, 2020 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-33100280

RESUMEN

BACKGROUND: We investigated the long-term clinical and hemodynamic outcomes after aortic valve replacement (AVR) with a 17-mm mechanical valve.Methods and Results:Between January 2005 and December 2011, 80 patients with aortic stenosis underwent AVR with the 17-mm St. Jude Medical Regent prosthetic valve. Echocardiography was performed preoperatively, at discharge, and at follow-up, which was performed at least 2 years postoperatively (median interval, 7.3 years). Prosthesis-patient mismatch (PPM) was defined as an indexed effective orifice area <0.85 cm2/m2at discharge and occurred in 25 patients (31%). The median follow-up period was 8.7 years (100% complete). Overall in-hospital mortality was 2.5% (2 patients) with 27 late deaths (34%). The 5- and 10-year survival rates were 78.7% and 63.0%, respectively. Peripheral arterial disease and concomitant mitral valve repair were independent predictors of late mortality. The 5- and 10-year freedom from major adverse valve-related events (MAVRE) rates were 91.6% and 83.5%, respectively. PPM at discharge did not affect long-term survival, freedom from MAVRE, or freedom from heart failure. Echocardiographic data at follow-up revealed a significant reduction in the mean left ventricular mass index (LVMI). LVMI reduction observed at follow-up was similar between patients with and without PPM. CONCLUSIONS: AVR with the 17-mm mechanical prosthesis had acceptable long-term clinical and hemodynamic outcomes. Significant reduction in LVMI was observed regardless of PPM.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía , Estudios de Seguimiento , Mortalidad Hospitalaria , Humanos , Diseño de Prótesis , Tasa de Supervivencia , Resultado del Tratamiento
16.
Artif Organs ; 44(11): E470-E481, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32420625

RESUMEN

A minimized perfusion circuit (MPC) may reduce transfusion requirement and inflammatory response. Its use, however, has not been standardized for complicated cardiovascular surgery. We assessed outcomes of surgery for acute type A aortic dissection (ATAAD) performed with a MPC under circulatory arrest. The study involved 706 patients treated surgically for ATAAD (by hemiarch repair [n = 571] or total arch repair [n = 135]). Total arch repair was performed using selective antegrade cerebral perfusion. Our MPC, a semi-closed bypass system, incorporating a completely closed circuit and a level-sensing reservoir in the venous circuit, was used. Clinical variables, transfusion volume, and outcomes were investigated in patients who underwent hemiarch repair or total arch repair. The overall incidences of shock, organ ischemia, and coagulopathy (prothrombin time-international normalized ratio >1.5) were 26%, 35%, and 8%, respectively. Mean extracorporeal circulation (ECC) time was 149 minutes for the hemiarch repair group and 241 minutes for the total arch repair group, respectively. No patient required conversion to conventional ECC, and there were no complications related to the use of the MPC. The need for transfusion (98% vs. 91%, P = .017) and median transfusion volume (1970 vs. 1680 mL, P = .002) was increased in the total arch repair group. Neither in-hospital mortality (total arch; 12% vs. hemiarch; 7%, P = .11) nor 10-year survival (74.4% vs. 68.4%, P = .79) differed significantly. Outcomes of surgery for ATAAD performed with the MPC were acceptable. The possibility of transfusion and transfusion volume remains high during such surgery, despite the use of the MPC.


Asunto(s)
Disección Aórtica/cirugía , Procedimientos Quirúrgicos Vasculares/instrumentación , Anciano , Diseño de Equipo , Circulación Extracorporea/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Perfusión/instrumentación , Resultado del Tratamiento
17.
J Card Surg ; 35(8): 2103-2105, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32652642

RESUMEN

A 59-year-old man with acute mitral regurgitation due to papillary muscle rupture after myocardial infarction was admitted to our hospital. He underwent emergent mitral valve replacement with a mechanical valve by median sternotomy. Although postoperative echocardiography showed no sign of a ventricular aneurysm, echocardiography performed 5 weeks after the surgery showed enlarging left ventricular pseudoaneurysm of the inferior to the posterior cardiac wall. He underwent dacron patch closure of the orifice by fifth intercostal left thoracotomy. The postoperative course was uneventful and he was discharged on postoperative day 10. The patient was successfully treated for two life-threatening complications occurring subsequently after myocardial infarction.


Asunto(s)
Aneurisma Falso/cirugía , Aneurisma Cardíaco/cirugía , Rotura Cardíaca Posinfarto/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Ventrículos Cardíacos/cirugía , Válvula Mitral/cirugía , Infarto del Miocardio/complicaciones , Músculos Papilares , Complicaciones Posoperatorias , Toracotomía/métodos , Aneurisma Falso/etiología , Aneurisma Cardíaco/etiología , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
18.
J Card Surg ; 35(11): 3220-3223, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33047314

RESUMEN

A 67-year-old woman with a prior history of aortic dissection was admitted for enlarging the thoracoabdominal aortic aneurysm (TAAA). She has received multiple treatments including Bentall procedure, hemiarch replacement, and subsequent endovascular procedures for the closure of re-entry. Preoperative computed tomography revealed previously implanted thoracic endograft from distal arch to superior mesenteric artery with dissected TAAA measuring up to 70 mm in diameter. Re-entry was observed at bilateral common iliac arteries. The patient was successfully treated by endovascular treatment using a fenestrated stent graft to obtain a landing zone for parallel endograft technique to the iliac arteries for the closure of re-entry.


Asunto(s)
Aorta Abdominal/cirugía , Aorta Torácica/cirugía , Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Procedimientos Endovasculares/métodos , Anciano , Disección Aórtica/diagnóstico por imagen , Aorta Abdominal/diagnóstico por imagen , Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta/diagnóstico por imagen , Femenino , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/cirugía , Reoperación , Stents , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
19.
J Card Surg ; 35(12): 3581-3584, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32906189

RESUMEN

We report herein the successful treatment of a case of acute type A aortic dissection complicated by cardiac tamponade and mesenteric malperfusion. The patient was a 60-year-old man with back and abdominal pain and in shock, who was transported to our hospital 2 h after symptom onset. Computed tomography revealed DeBakey type I dissection with massive hemopericardium and obstruction of both the celiac artery and superior mesenteric artery. After emergency pericardiotomy and removal of the hematoma, superior mesenteric artery-external iliac artery bypass was constructed with a vein graft, and this restored mesenteric perfusion. Open distal hemiarch replacement was then performed. The postoperative course was uneventful. Superior mesenteric artery revascularization achieved immediately after release of the cardiac tamponade prevented further mesenteric ischemia and paved the way for the aortic repair.


Asunto(s)
Disección Aórtica , Taponamiento Cardíaco , Isquemia Mesentérica , Disección Aórtica/complicaciones , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Taponamiento Cardíaco/etiología , Taponamiento Cardíaco/cirugía , Arteria Celíaca , Humanos , Masculino , Arteria Mesentérica Superior/diagnóstico por imagen , Arteria Mesentérica Superior/cirugía , Isquemia Mesentérica/diagnóstico por imagen , Isquemia Mesentérica/cirugía , Persona de Mediana Edad
20.
Surg Today ; 50(10): 1213-1222, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32253513

RESUMEN

PURPOSE: We investigated the etiology and impact on outcomes of polycystic kidney disease in patients with abdominal aortic aneurysm. METHODS: Eight-hundred patients who underwent open (n = 603) or endovascular aortic repair (n = 197) were divided into three groups: no cyst (n = 204), non-polycystic kidney (n = 503), and polycystic kidney (≥ 5 cysts in the bilateral kidneys, n = 93). The characteristics and outcomes were compared among the groups. RESULTS: In the polycystic kidney group, the age was increased and the proportions of patients with male sex, hypertension, and estimated glomerular filtration rate < 30 mL/min/1.73 m2 were greater. The overall hospital mortality rates were similar. The incidence of acute kidney injury after elective open aortic repair was increased in the polycystic kidney group (12%, 17%, and 29%, P = 0.020). In the polycystic kidney group, 80 patients did not have renal enlargement or a family history of renal disease, while 13 (corresponding to 1.6% [13/800] of the overall patients), had renal enlargement, suggesting the possibility of hereditary polycystic kidney disease. CONCLUSIONS: In our cohort, 1.6% of the patients with abdominal aortic aneurysm who underwent surgery were at risk of hereditary polycystic kidney disease. Polycystic kidney disease was associated with acute kidney injury after open aortic repair.


Asunto(s)
Lesión Renal Aguda/epidemiología , Lesión Renal Aguda/etiología , Aneurisma de la Aorta Abdominal/cirugía , Enfermedades Renales Poliquísticas/complicaciones , Enfermedades Renales Poliquísticas/genética , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Factores de Edad , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/epidemiología , Comorbilidad , Procedimientos Endovasculares , Femenino , Tasa de Filtración Glomerular , Humanos , Hipertensión , Masculino , Persona de Mediana Edad , Enfermedades Renales Poliquísticas/epidemiología , Prevalencia , Factores Sexuales , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA