1.
J Magn Reson Imaging ; 2023 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-37668040

RESUMEN

BACKGROUND: In vivo cartilage deformation has been studied by static magnetic resonance imaging (MRI) with in situ loading, but knowledge about strain dynamics after load onset and release is scarce. PURPOSE: To measure the dynamics of patellofemoral cartilage deformation and recovery in response to in situ loading and unloading by using MRI with prospective motion correction. STUDY TYPE: Prospective. SUBJECTS: Ten healthy male volunteers (age: [31.4 ± 3.2] years). FIELD STRENGTH/SEQUENCE: T1-weighted RF-spoiled 2D gradient-echo sequence with a golden angle radial acquisition scheme, augmented with prospective motion correction, at 3 T. ASSESSMENT: In situ knee loading was realized with a flexion angle of approximately 40° using an MR-compatible pneumatic loading device. The loading paradigm consisted of 2 minutes of unloaded baseline followed by a 5-minute loading bout with 50% body weight and an unloading period of 38 minutes. The cartilage strain was assessed as the mean distance between patellar and femoral bone-cartilage interfaces as a percentage of the initial (pre-load) distance. STATISTICAL TESTS: Wilcoxon signed-rank tests (significance level: P < 0.05), Pearson correlation coefficient (r). RESULTS: The cartilage compression and recovery behavior was characterized by a viscoelastic response. The elastic compression ([-12.5 ± 3.1]%) was significantly larger than the viscous compression ([-7.6 ± 1.5]%) and the elastic recovery ([10.5 ± 2.1]%) was significantly larger than the viscous recovery ([6.1 ± 1.8]%). There was a significant residual offset strain ([-3.6 ± 2.3]%) across the cohort. A significant negative correlation between elastic compression and elastic recovery was observed (r = -0.75). DATA CONCLUSION: The in vivo cartilage compression and recovery time course in response to loading was successfully measured via dynamic MRI with prospective motion correction. The clinical relevance of the strain characteristics needs to be assessed in larger subject and patient cohorts. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.

2.
J Magn Reson Imaging ; 57(3): 690-705, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36326548

RESUMEN

Complex engineered systems are often equipped with suites of sensors and ancillary devices that monitor their performance and maintenance needs. MRI scanners are no different in this regard. Some of the ancillary devices available to support MRI equipment, the ones of particular interest here, have the distinction of actually participating in the image acquisition process itself. Most commonly, such devices are used to monitor physiological motion or variations in the scanner's imaging fields, allowing the imaging and/or reconstruction process to adapt as imaging conditions change. "Classic" examples include electrocardiography (ECG) leads and respiratory bellows to monitor cardiac and respiratory motion, which have been standard equipment in scan rooms since the early days of MRI. Since then, many additional sensors and devices have been proposed to support MRI acquisitions. The main physical properties that they measure may be primarily "mechanical" (eg acceleration, speed, and torque), "acoustic" (sound and ultrasound), "optical" (light and infrared), or "electromagnetic" in nature. A review of these ancillary devices, as currently available in clinical and research settings, is presented here. In our opinion, these devices are not in competition with each other: as long as they provide useful and unique information, do not interfere with each other and are not prohibitively cumbersome to use, they might find their proper place in future suites of sensors. In time, MRI acquisitions will likely include a plurality of complementary signals. A little like the microbiome that provides genetic diversity to organisms, these devices can provide signal diversity to MRI acquisitions and enrich measurements. Machine-learning (ML) algorithms are well suited at combining diverse input signals toward coherent outputs, and they could make use of all such information toward improved MRI capabilities. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 1.


Asunto(s)
Corazón , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Corazón/fisiología , Electrocardiografía , Movimiento (Física) , Movimiento/fisiología
3.
Magn Reson Med ; 86(3): 1284-1298, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33829538

RESUMEN

PURPOSE: Prospective motion correction (PMC) and retrospective motion correction (RMC) have different advantages and limitations. The present work aims to combine the advantages of both for rigid body motion, aiming at correcting for faster motions than was previously achievable. Additionally, it provides insights into the effects of motion on pulse sequences and MR signals with a goal of further improving motion correction in the future. METHODS: The effective encoding trajectory and a global phase offset in a moving object are calculated based on complete gradient waveforms of an arbitrary sequence and a continuous motion model. These data are used to feed the forward signal model, which is then used in iterative image reconstruction to suppress the artifacts still present after the PMC. RESULTS: Verification experiments with a rotation phantom and in vivo were performed. Predictions of simulated motion artifacts for PMC based on sequence waveforms are very accurate. The performance at combined PMC+RMC is limited by Nyquist violations in the sampled k-space and can be compensated by oversampling. CONCLUSION: The combined correction results in better images than pure PMC in the presence of fast motion. The predictions of artifacts are very accurate, allowing for comparing sequences or protocols in simulations. The observed artifacts due to Nyquist violations are expected to be corrected by utilizing parallel imaging.


Asunto(s)
Artefactos , Imagen por Resonancia Magnética , Algoritmos , Procesamiento de Imagen Asistido por Computador , Movimiento (Física) , Fantasmas de Imagen , Estudios Prospectivos , Estudios Retrospectivos
4.
Magn Reson Med ; 86(2): 852-865, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33724546

RESUMEN

PURPOSE: To investigate the effects of prospective motion correction on turbo spin echo sequences and optimize motion correction approaches, mitigating signal dropout artifacts caused by the imperfections of motion tracking data. METHODS: Signal dropout artifacts caused by undesired phase deviations introduced by tracking errors are analyzed theoretically. To reduce the adverse effect of such deviations, two approaches are proposed: (1) freezing the correction for example, for even-numbered or higher number of echoes and (2) shifting the correction event prior to the left crusher gradient preceding the refocusing pulse. A comprehensive analysis is presented, including both signal simulations and experimental verifications in phantoms and in vivo. Performance of the proposed approach is validated in two healthy volunteers imaged under two types of motion conditions simulating inadvertent fast motions associated with discomfort and continuous large motions. RESULTS: The results show that the proposed optimization is able to efficiently correct for the motion artifacts and at the same time avoid signal dropout artifacts. Specifically, performing correction every 4th echo prior to the left crusher gradient was shown to improve image quality. CONCLUSION: An optimization approach is proposed to exploit the potential of external tracking for intra-echo-train motion artifact correction for turbo spin echo sequences.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Artefactos , Encéfalo/diagnóstico por imagen , Humanos , Movimiento (Física) , Fantasmas de Imagen , Estudios Prospectivos
5.
MAGMA ; 32(4): 437-447, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30649708

RESUMEN

OBJECTIVE: The applicability of the balanced steady-state free precession (bSSFP) sequence to the field of MR microscopy was investigated, since the potentially high SNR makes bSSFP attractive. However, particularly at ultra-high magnetic fields, a number of constraints emerge: the frequency sensitivity of the bSSFP signal, the duty cycle of the imaging gradients, and the intrinsic diffusion attenuation of the steady state due to the imaging gradients. MATERIALS AND METHODS: Optimization of the bSSFP sequence was performed on three imaging systems (7 T and 9.4 T) suited for MR microscopy. Since biological samples are often imaged in the very proximity of materials from sample containers/holder or devices such as electrodes, several microscopy phantoms representing such circumstances were fabricated and examined with 3D bSSFP. RESULTS: Artifact-free microscopic bSSFP images could be obtained with voxel sizes down to 16 µm × 16 µm × 78 µm and with an SNR gain of 25% over standard gradient echo images. CONCLUSION: With appropriate choice of phantom materials, optimization of the flip angle to the diffusion-attenuated steady state and protocols considering duty-cycle limitations, bSSFP can be a valuable tool in MR microscopy.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Microscopía/métodos , Algoritmos , Artefactos , Simulación por Computador , Aumento de la Imagen , Procesamiento de Imagen Asistido por Computador/métodos , Campos Magnéticos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Relación Señal-Ruido , Agua
6.
PLoS One ; 16(5): e0250903, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33970948

RESUMEN

We present the development of a dual-mode imaging platform that combines optical microscopy with magnetic resonance microscopy. Our microscope is designed to operate inside a 9.4T small animal scanner with the option to use a 72mm bore animal RF coil or different integrated linear micro coils. With a design that minimizes the magnetic distortions near the sample, we achieved a field inhomogeneity of 19 ppb RMS. We further integrated a waveguide in the optical layout for the electromagnetic shielding of the camera, which minimizes the noise increase in the MR and optical images below practical relevance. The optical layout uses an adaptive lens for focusing, 2 × 2 modular combinations of objectives with 0.6mm to 2.3mm field of view and 4 configurable RGBW illumination channels and achieves a plano-apochromatic optical aberration correction with 0.6µm to 2.3µm resolution. We present the design, implementation and characterization of the prototype including the general optical and MR-compatible design strategies, a knife-edge optical characterization and different concurrent imaging demonstrations.


Asunto(s)
Diseño de Equipo/instrumentación , Imagen por Resonancia Magnética/métodos , Microscopía/métodos , Imagen Óptica/métodos , Animales , Imagen por Resonancia Magnética/instrumentación , Microscopía/instrumentación , Imagen Óptica/instrumentación , Fantasmas de Imagen , Ondas de Radio