Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 223
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Ophthalmology ; 131(6): 682-691, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38160882

RESUMEN

PURPOSE: To report long-term results from a phase 1/2a clinical trial assessment of a scaffold-based human embryonic stem cell-derived retinal pigmented epithelium (RPE) implant in patients with advanced geographic atrophy (GA). DESIGN: A single-arm, open-label phase 1/2a clinical trial approved by the United States Food and Drug Administration. PARTICIPANTS: Patients were 69-85 years of age at the time of enrollment and were legally blind in the treated eye (best-corrected visual acuity [BCVA], ≤ 20/200) as a result of GA involving the fovea. METHODS: The clinical trial enrolled 16 patients, 15 of whom underwent implantation successfully. The implant was administered to the worse-seeing eye with the use of a custom subretinal insertion device. The companion nonimplanted eye served as the control. The primary endpoint was at 1 year; thereafter, patients were followed up at least yearly. MAIN OUTCOME MEASURES: Safety was the primary endpoint of the study. The occurrence and frequency of adverse events (AEs) were determined by scheduled eye examinations, including measurement of BCVA and intraocular pressure and multimodal imaging. Serum antibody titers were collected to monitor systemic humoral immune responses to the implanted cells. RESULTS: At a median follow-up of 3 years, fundus photography revealed no migration of the implant. No unanticipated, severe, implant-related AEs occurred, and the most common anticipated severe AE (severe retinal hemorrhage) was eliminated in the second cohort (9 patients) through improved intraoperative hemostasis. Nonsevere, transient retinal hemorrhages were noted either during or after surgery in all patients as anticipated for a subretinal surgical procedure. Throughout the median 3-year follow-up, results show that implanted eyes were more likely to improve by > 5 letters of BCVA and were less likely to worsen by > 5 letters compared with nonimplanted eyes. CONCLUSIONS: This report details the long-term follow-up of patients with GA to receive a scaffold-based stem cell-derived bioengineered RPE implant. Results show that the implant, at a median 3-year follow-up, is safe and well tolerated in patients with advanced dry age-related macular degeneration. The safety profile, along with the early indication of efficacy, warrants further clinical evaluation of this novel approach for the treatment of GA. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Atrofia Geográfica , Epitelio Pigmentado de la Retina , Agudeza Visual , Humanos , Atrofia Geográfica/cirugía , Atrofia Geográfica/fisiopatología , Epitelio Pigmentado de la Retina/trasplante , Epitelio Pigmentado de la Retina/patología , Anciano , Agudeza Visual/fisiología , Femenino , Anciano de 80 o más Años , Masculino , Estudios de Seguimiento , Tomografía de Coherencia Óptica , Células Madre Embrionarias Humanas/trasplante , Células Madre Embrionarias Humanas/citología , Trasplante de Células Madre , Resultado del Tratamiento
2.
Int J Mol Sci ; 25(7)2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38612560

RESUMEN

Retinal degenerative diseases, including age-related macular degeneration and retinitis pigmentosa, significantly contribute to adult blindness. The Royal College of Surgeons (RCS) rat is a well-established disease model for studying these dystrophies; however, molecular investigations remain limited. We conducted a comprehensive analysis of retinal degeneration in RCS rats, including an immunodeficient RCS (iRCS) sub-strain, using ocular coherence tomography, electroretinography, histology, and molecular dissection using transcriptomics and immunofluorescence. No significant differences in retinal degeneration progression were observed between the iRCS and immunocompetent RCS rats, suggesting a minimal role of adaptive immune responses in disease. Transcriptomic alterations were primarily in inflammatory signaling pathways, characterized by the strong upregulation of Tnfa, an inflammatory signaling molecule, and Nox1, a contributor to reactive oxygen species (ROS) generation. Additionally, a notable decrease in Alox15 expression was observed, pointing to a possible reduction in anti-inflammatory and pro-resolving lipid mediators. These findings were corroborated by immunostaining, which demonstrated increased photoreceptor lipid peroxidation (4HNE) and photoreceptor citrullination (CitH3) during retinal degeneration. Our work enhances the understanding of molecular changes associated with retinal degeneration in RCS rats and offers potential therapeutic targets within inflammatory and oxidative stress pathways for confirmatory research and development.


Asunto(s)
Degeneración Macular , Degeneración Retiniana , Retinitis Pigmentosa , Cirujanos , Humanos , Adulto , Animales , Ratas , Retina
3.
Int J Mol Sci ; 25(4)2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38396738

RESUMEN

The emergence and mutation of pathogenic viruses have been occurring at an unprecedented rate in recent decades. The coronavirus disease 2019 (COVID-19) pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has developed into a global public health crisis due to extensive viral transmission. In situ RNA mapping has revealed angiotensin-converting enzyme 2 (ACE2) expression to be highest in the nose and lower in the lung, pointing to nasal susceptibility as a predominant route for infection and the cause of subsequent pulmonary effects. By blocking viral attachment and entry at the nasal airway using a cyclodextrin-based formulation, a preventative therapy can be developed to reduce viral infection at the site of entry. Here, we assess the safety and antiviral efficacy of cyclodextrin-based formulations. From these studies, hydroxypropyl beta-cyclodextrin (HPBCD) and hydroxypropyl gamma-cyclodextrin (HPGCD) were then further evaluated for antiviral effects using SARS-CoV-2 pseudotypes. Efficacy findings were confirmed with SARS-CoV-2 Delta variant infection of Calu-3 cells and using a K18-hACE2 murine model. Intranasal pre-treatment with HPBCD-based formulations reduced viral load and inflammatory signaling in the lung. In vitro efficacy studies were further conducted using lentiviruses, murine hepatitis virus (MHV), and influenza A virus subtype H1N1. These findings suggest HPBCD may be used as an agnostic barrier against transmissible pathogens, including but not limited to SARS-CoV-2.


Asunto(s)
Ciclodextrinas , Subtipo H1N1 del Virus de la Influenza A , Virosis , beta-Ciclodextrinas , Humanos , Ratones , Animales , Antivirales/farmacología , Antivirales/uso terapéutico , beta-Ciclodextrinas/farmacología
4.
Curr Opin Ophthalmol ; 34(5): 431-436, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37459295

RESUMEN

PURPOSE OF REVIEW: The Future Vision Forum discussed the current state of Human Centered Computing and the future of data collection, curation, and collation in ophthalmology. Although the uptake of electronic health record (EHR) systems and the digitization of healthcare data is encouraging, there are still barriers to implementing a specialty-wide clinical trial database. The article identifies several critical opportunities, including the need for standardization of image metadata and data, the establishment of a centralized trial database, incentives for clinicians and trial sponsors to participate, and resolving ethical concerns surrounding data ownership. FINDINGS: Recommendations to overcome these challenges include the standardization of image metadata using the Digital Imaging and Communications in Medicine (DICOM) guidelines, the establishment of a centralized trial database that uses federated learning (FL), and the use of FL to facilitate cross-institutional collaboration for rare diseases. Forum faculty suggests incentives will accelerate artificial intelligence, digital innovation projects, and data sharing agreements to empower patients to release their data. SUMMARY: A specialty-wide clinical trial database could provide invaluable insights into the natural history of disease, pathophysiology, why trials fail, and improve future clinical trial design. However, overcoming the barriers to implementation will require continued discussion, collaboration, and collective action from stakeholders across the ophthalmology community.


Asunto(s)
Inteligencia Artificial , Oftalmología , Humanos
5.
J Heat Transfer ; 144(3): 031208, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35833154

RESUMEN

The purpose of this study is to investigate the effect of partial liquefaction (due to ageing) of the vitreous humor on the transport of ocular drugs. In our model, the gel part of the vitreous is treated as a Darcy-type porous medium. A spherical region within the porous part of vitreous is in a liquid state which, for computational purposes, is also treated as a porous medium but with a much higher permeability. Using the finite element method, a time-dependent, three-dimensional model has been developed to computationally simulate (using the Petrov-Galerkin method) the transport of intravitreally injected macromolecules where both convection and diffusion are present. From a fluid physics and transport phenomena perspective, the results show many interesting features. For pressure-driven flow across the vitreous, the flow streamlines converge into the liquefied region as the flow seeks the fastest path of travel. Furthermore, as expected, with increased level of liquefaction, the overall flow rate increases for a given pressure drop. We have quantified this effect for various geometrical considerations. The flow convergence into the liquefied region has important implication for convective transport. One effect is the clear diversion of the drug as it reaches the liquefied region. In some instances, the entry point of the drug in the retinal region gets slightly shifted due to liquefaction. While the model has many approximations and assumptions, the focus is illustrating the effect of liquefaction as one of the building blocks toward a fully comprehensive model.

6.
Ophthalmology ; 128(3): 453-462, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32858064

RESUMEN

PURPOSE: Bioelectronic retinal prostheses that stimulate the remaining inner retinal neurons, bypassing degenerated photoreceptors, have been demonstrated to restore some vision in patients blinded by retinitis pigmentosa (RP). These implants encode luminance of the visual scene into electrical stimulation, however, leaving out chromatic information. Yet color plays an important role in visual processing when it comes to recognizing objects and orienting to the environment, especially at low spatial resolution as generated by current retinal prostheses. In this study, we tested the feasibility of partially restoring color perception in blind RP patients, with the aim to provide chromatic information as an extra visual cue. DESIGN: Case series. PARTICIPANTS: Seven subjects blinded by advanced RP and monocularly fitted with an epiretinal prosthesis. METHODS: Frequency-modulated electrical stimulation of retina was tested. Phosphene brightness was controlled by amplitude tuning, and color perception was acquired using the Red, Yellow, Green, and Blue (RYGB) hue and saturation scaling model. MAIN OUTCOME MEASURES: Brightness and color of the electrically elicited visual perception reported by the subjects. RESULTS: Within the tested parameter space, 5 of 7 subjects perceived chromatic colors along or nearby the blue-yellow axis in color space. Aggregate data obtained from 20 electrodes of the 5 subjects show that an increase of the stimulation frequency from 6 to 120 Hz shifted color perception toward blue/purple despite a significant inter-subject variation in the transition frequency. The correlation between frequency and blue-yellow perception exhibited a good level of consistency over time and spatially matched multi-color perception was possible with simultaneous stimulation of paired electrodes. No obvious correlation was found between blue sensations and array placement or status of visual impairment. CONCLUSIONS: These findings present a strategy for the generation and control of color perception along the blue-yellow axis in blind patients with RP by electrically stimulating the retina. It could transform the current prosthetic vision landscape by leading in a new direction beyond the efforts to improve the visual acuity. This study also offers new insights into the response of our visual system to electrical stimuli in the photoreceptor-less retina that warrant further mechanistic investigation.


Asunto(s)
Ceguera/fisiopatología , Percepción de Color/fisiología , Terapia por Estimulación Eléctrica , Retina/fisiopatología , Retinitis Pigmentosa/terapia , Prótesis Visuales , Anciano , Visión de Colores/fisiología , Electrodos Implantados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fosfenos , Células Fotorreceptoras de Vertebrados/fisiología , Retinitis Pigmentosa/fisiopatología , Umbral Sensorial/fisiología , Agudeza Visual
7.
Graefes Arch Clin Exp Ophthalmol ; 259(2): 405-412, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32809071

RESUMEN

PURPOSE: Traction exerted on the vitreous base during vitrectomy poses a risk for retinal tears. We aimed to quantify core vitreous traction during vitrectomy using spring return and pneumatic cutters. METHODS: Juvenile porcine vitreous was vacuum held in a vitreous bath while traction was measured using precision force gauge during vitrectomy. The parameters included were aspiration rate, cut-rate, cutter size, and machine types. RESULTS: An empirical probabilistic model was developed. The traction was proportional to the aspiration rate but insignificantly dependent on the cut-rate. The traction probability was inversely proportional to the exponential function of the traction (p < 0.05). The traction was < 0.003 N for 99% of the time using either 23- or 25-gauge cutters. CONCLUSION: The tractions measured were considered similar to the causative forces of an iatrogenic retinal tear during a pars plana vitrectomy. The results provide a safety reference matrix of instrumental parameters during vitrectomy.


Asunto(s)
Vitrectomía , Cuerpo Vítreo , Animales , Humanos , Microcirugia , Modelos Estadísticos , Porcinos , Tracción , Cuerpo Vítreo/cirugía
8.
Ophthalmologica ; 244(4): 291-300, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33279905

RESUMEN

PURPOSE: To report the anatomical and functional outcomes of Argus II retinal prosthesis implantation in Korean patients. METHODS: We included 5 consecutive patients with end-stage retinitis pigmentosa (RP) who underwent Argus II retinal prosthesis implantation and were followed for at least 12 months. The transcorneal electrical evoked response was utilized for patient selection. We used intraoperative optical coherence tomography (OCT) for optimal placement of the array and provided specialized vision rehabilitation training. A morphological evaluation using SD-OCT and a functional evaluation using computer-based visual function tests, a letter-reading ability test, and the Functional Low-Vision Observer Rated Assessment (FLORA) were conducted. RESULTS: Postoperatively, the array was completely apposed to the retinal surface in all eyes, except for one eye which had a preexisting macular concavity. Fibrosis-like tissues of ≥50-µm thickness developed at the interface in 2 eyes. All of the patients showed improvement in computer-based visual function tests and could read ETDRS letters at a distance of 50 cm. Three patients could read Korean words. FLORA was improved in all patients, mainly in tasks of visual mobility, daily activities, and social interactions. CONCLUSIONS: Along with good anatomical outcomes and specialized rehabilitation practices, recipients of the Argus II implant showed profound improvements in functional vision and mobility.


Asunto(s)
Retinitis Pigmentosa , Prótesis Visuales , Humanos , Implantación de Prótesis , República de Corea , Retina/diagnóstico por imagen , Retina/cirugía , Retinitis Pigmentosa/diagnóstico , Tomografía de Coherencia Óptica
9.
J Heat Transfer ; 143(10): 101201, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-35832287

RESUMEN

Sustained ocular drug delivery systems are necessary for patients needing regular drug therapy since frequent injection is painful, undesirable, and risky. One type of sustained-release systems includes pellets loaded with the drug, encapsulated in a porous shell that can be injected into the vitreous humor. There the released drug diffuses while the physiological flow of water provides the convective transport. The fluid flow within the vitreous is described by Darcy's equations for the analytical model and Brinkman flow for the computational analysis while the drug transport is given by the classical convection-diffusion equation. Since the timescale for the drug depletion is quite large, for the analytical model, we consider the exterior surrounding the capsule to be quasi-steady and the interior is time dependent. In the vitreous, the fluid-flow process is relatively slow, and meaningful results can be obtained for small Peclet number whereby a perturbation analysis is possible. For an isolated capsule, with approximately uniform flow in the far field around it, the mass-transfer problem requires singular perturbation with inner and outer matching. The computational model, besides accommodating the ocular geometry, allows for a fully time-dependent mass-concentration solution and also admits moderate Peclet numbers. As expected, the release rate diminishes with time as the drug depletion lowers the driving potential. The predictive results are sufficient general for a range of capsule permeability values and are useful for the design of the sustained-release microspheres as to the requisite permeability for specific drugs.

10.
J Heat Transfer ; 143(3): 032101, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-33612856

RESUMEN

In order to measure the effective diffusion coefficient D of Bevacizumab (Avastin, Genentech) in the vitreous humor, a new technique is developed based on the "contour method" and in vivo optical coherence tomography measurements. After injection of Bevacizumab-fluorescein conjugated compound solution into the rabbit eye, the contours of drug concentration distribution at the subsurface of injection were tracked over time. The 2D contours were extrapolated to 3D contours using reasonable assumptions and a numerically integrated analytical model was developed for the theoretical contours for the irregularly shaped drug distribution in the experimental result. By floating the diffusion coefficient, different theoretical contours were constructed and the least-squares best fit to the experimental contours was performed at each time point to get the best fit solution. The approach generated consistent diffusion coefficient values based on the experiments on four rabbit eyes over a period of 3 h each, which gave D = 1.2 ± 0.6 × 10 - 6 cm 2 / s , and the corresponding theoretical contours matched well with the experimental contours. The quantitative measurement of concentration using optical coherence tomography and fluorescein labeling gives a new approach for the "noncontact" in vivo drug distribution measurement within vitreous.

11.
Retina ; 40(2): 303-311, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31972801

RESUMEN

PURPOSE: To analyze and provide an overview of the incidence, management, and prevention of conjunctival erosion in Argus II clinical trial subjects and postapproval patients. METHODS: This retrospective analysis followed the results of 274 patients treated with the Argus II Retinal Prosthesis System between June 2007 and November 2017, including 30 subjects from the US and European clinical trials, and 244 patients in the postapproval phase. Results were gathered for incidence of a serious adverse event, incidence of conjunctival erosion, occurrence sites, rates of erosion, and erosion timing. RESULTS: Overall, 60% of subjects in the clinical trial subjects versus 83% of patients in the postapproval phase did not experience device- or surgery-related serious adverse events. In the postapproval phase, conjunctival erosion had an incidence rate of 6.2% over 5 years and 11 months. In 55% of conjunctival erosion cases, erosion occurred in the inferotemporal quadrant, 25% in the superotemporal quadrant, and 20% in both. Sixty percent of the erosion events occurred in the first 15 months after implantation, and 85% within the first 2.5 years. CONCLUSION: Reducing occurrence of conjunctival erosion in patients with the Argus II Retinal Prosthesis requires identification and minimization of risk factors before and during implantation. Implementing inverted sutures at the implant tabs, use of graft material at these locations as well as Mersilene rather than nylon sutures, and accurate Tenon's and conjunctiva closure are recommended for consideration in all patients.


Asunto(s)
Conjuntiva/cirugía , Enfermedades de la Conjuntiva/etiología , Complicaciones Posoperatorias/etiología , Implantación de Prótesis/efectos adversos , Retinitis Pigmentosa/cirugía , Prótesis Visuales/efectos adversos , Enfermedades de la Conjuntiva/epidemiología , Enfermedades de la Conjuntiva/prevención & control , Europa (Continente)/epidemiología , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/prevención & control , Implantación de Prótesis/métodos , Estudios Retrospectivos , Estados Unidos/epidemiología
12.
J Porous Media ; 23(2): 195-206, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32494116

RESUMEN

The hydraulic conductivity of the vitreous humor has been measured for the bovine eye. The experiment was carried out by placing it within upright cylindrical chamber, open at both ends, and letting its liquid content drain out of the bottom opening by gravity, through a 20µm nylon mesh filter. Additional negative pressure was provided at the exit by a hanging drainage tube. The diminishing vitreous volume was measured in terms of the height in the chamber and recorded as a function of time. The reduction in the vitreous liquid content also caused the hydraulic conductivity to reduce and this parameter was quantified on the basis of previously-developed theories of fibrous porous media that have been very well established. A theoretical model with a fully analytical expression for the vitreous volume undergoing drainage was developed and used as a least-squares best fit to deliver the initial hydraulic conductivity value of K 0/µ=(7.8 ± 3.1) × 10-12 m2 (Pa-s). The measurements were made with the hyaloid membrane intact and therefore represents an effective conductivity for the entire system, including possible variations within the vitreous.

13.
Adv Exp Med Biol ; 1185: 569-574, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31884672

RESUMEN

The goal of this study was to quantitatively assess retinal thickness using spectral domain optical coherence tomography (SD-OCT) after subretinal implantation of human embryonic stem cell-derived retinal pigment epithelium in a porcine model. The implant is called CPCB-RPE1 for the California Project to Cure Blindness-Retinal Pigment Epithelium 1. Data were derived from previous experiments on 14 minipigs that received either subretinal implantation of CPCB-RPE1 (n = 11) or subretinal bleb formation alone (sham; n = 3) using previously described methods and procedures (Brant Fernandes et al. Ophthalmic Surg Lasers Imaging Retina 47:342-51, 2016; Martynova et al. (2016) Koss et al. Graefes Arch Clin Exp Ophthalmol 254:1553-65, 2016; Hu et al. Ophthalmic Res 48:186-91, 2016; Martynova et al. ARVO Abstract 2016. SD-OCT retinal thickness (RT) and sublayer thickness over the implant were compared with topographically similar preimplantation regions as described previously Martynova et al. ARVO Abstract 2016. Imaging results were compared to postmortem histology using hematoxylin-eosin staining. RT overlying the CPCB-RPE1 postimplantation was not significantly different from preimplantation (308 ± 72 µm vs 292 ± 41 µm; p = 0.44). RT was not significantly different before and after implantation in any retinal sublayer at 1 month. Histology demonstrated grossly normal retinal anatomy as well as photoreceptor interdigitation with RPE.


Asunto(s)
Células Madre Embrionarias Humanas/trasplante , Retina/diagnóstico por imagen , Epitelio Pigmentado de la Retina/citología , Tomografía de Coherencia Óptica , Animales , California , Humanos , Porcinos
14.
J Heat Transfer ; 141(5): 050801, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-35832509

RESUMEN

In relation to intravitreal drug delivery, predictive mathematical models for drug transport are being developed, and to effectively implement these for retinal delivery, the information on biophysical properties of various ocular tissues is fundamentally important. It is therefore necessary to accurately measure the diffusion coefficient of drugs and drug surrogates in the vitreous humor. In this review, we present the studies conducted by various researchers on such measurements over the last several decades. These include imaging techniques (fluorescence and magnetic resonance imaging (MRI)) that make use of introducing a contrast agent or a labeled drug into the vitreous and tracking its diffusive movement at various time points. A predictive model for the same initial conditions when matched with the experimental measurements provides the diffusion coefficient, leading to results for various molecules ranging in size from approximately 0.1 to 160 kDa. For real drugs, the effectiveness of this system depends on the successful labeling of the drugs with suitable contrast agents such as fluorescein and gadolinium or manganese so that fluorescence or MR imagining could be conducted. Besides this technique, some work has been carried out using the diffusion apparatus for measuring permeation of a drug across an excised vitreous body from a donor chamber to the receptor by sampling assays from the chambers at various time intervals. This has the advantage of not requiring labeling but is otherwise more disruptive to the vitreous. Some success with nanoparticles has been achieved using dynamic light scattering (DLS), and presently, radioactive labeling is being explored.

15.
Sensors (Basel) ; 19(8)2019 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-30999576

RESUMEN

Neurostimulation has proved to be an effective method for the restoration of visual perception lost due to retinal diseases. However, the clinically available retinal neurostimulation method is based on invasive electrodes, making it a high-cost and high-risk procedure. Recently, ultrasound has been demonstrated to be an effective way to achieve noninvasive neurostimulation. In this work, a novel racing array transducer with a contact lens shape is proposed for ultrasonic retinal stimulation. The transducer is flexible and placed outside the eyeball, similar to the application of a contact lens. Ultrasound emitted from the transducer can reach the retina without passing through the lens, thus greatly minimizing the acoustic absorption in the lens. The discretized Rayleigh-Sommerfeld method was employed for the acoustic field simulation, and patterned stimulation was achieved. A 5 MHz racing array transducer with different element numbers was simulated to optimize the array configuration. The results show that a 512-element racing array is the most appropriate configuration considering the necessary tradeoff between the element number and the stimulation resolution. The stimulation resolution at a focus of 24 mm is about 0.6 mm. The obtained results indicate that the proposed racing array design of the ultrasound transducer can improve the feasibility of an ultrasound retinal prosthesis.

16.
Graefes Arch Clin Exp Ophthalmol ; 256(11): 2113-2125, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30215097

RESUMEN

PURPOSE: To create new immunodeficient Royal College of Surgeons (RCS) rats by introducing the defective MerTK gene into athymic nude rats. METHODS: Female homozygous RCS (RCS-p+/RCS-p+) and male nude rats (Hsd:RH-Foxn1mu, mutation in the foxn1 gene; no T cells) were crossed to produce heterozygous F1 progeny. Double homozygous F2 progeny obtained by crossing the F1 heterozygotes was identified phenotypically (hair loss) and genotypically (RCS-p+ gene determined by PCR). Retinal degenerative status was confirmed by optical coherence tomography (OCT) imaging, electroretinography (ERG), optokinetic (OKN) testing, superior colliculus (SC) electrophysiology, and by histology. The effect of xenografts was assessed by transplantation of human embryonic stem cell-derived retinal pigment epithelium (hESC-RPE) and human-induced pluripotent stem cell-derived RPE (iPS-RPE) into the eye. Morphological analysis was conducted based on hematoxylin and eosin (H&E) and immunostaining. Age-matched pigmented athymic nude rats were used as control. RESULTS: Approximately 6% of the F2 pups (11/172) were homozygous for RCS-p+ gene and Foxn1mu gene. Homozygous males crossed with heterozygous females resulted in 50% homozygous progeny for experimentation. OCT imaging demonstrated significant loss of retinal thickness in homozygous rats. H&E staining showed photoreceptor thickness reduced to 1-3 layers at 12 weeks of age. Progressive loss of visual function was evidenced by OKN testing, ERG, and SC electrophysiology. Transplantation experiments demonstrated survival of human-derived cells and absence of apparent immune rejection. CONCLUSIONS: This new rat animal model developed by crossing RCS rats and athymic nude rats is suitable for conducting retinal transplantation experiments involving xenografts.


Asunto(s)
Modelos Animales de Enfermedad , Células Madre Embrionarias Humanas/trasplante , Síndromes de Inmunodeficiencia/terapia , Células Madre Pluripotentes Inducidas/trasplante , Distrofias Retinianas/terapia , Epitelio Pigmentado de la Retina/trasplante , Animales , Supervivencia Celular , Electrorretinografía , Femenino , Técnicas de Genotipaje , Supervivencia de Injerto/fisiología , Células Madre Embrionarias Humanas/fisiología , Humanos , Síndromes de Inmunodeficiencia/diagnóstico , Síndromes de Inmunodeficiencia/fisiopatología , Células Madre Pluripotentes Inducidas/fisiología , Masculino , Fenotipo , Ratas , Ratas Desnudas , Retina/fisiopatología , Distrofias Retinianas/diagnóstico , Distrofias Retinianas/fisiopatología , Epitelio Pigmentado de la Retina/fisiología , Tomografía de Coherencia Óptica , Tirosina Quinasa c-Mer/genética
17.
Retina ; 38(10): 1913-1919, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28796149

RESUMEN

PURPOSE: To evaluate visual and anatomical outcomes of diabetic tractional retinal detachment repaired with pars plana vitrectomy. METHODS: Operative records were used to retrospectively identify all patients with tractional retinal detachments secondary to proliferative diabetic retinopathy surgically repaired with pars plana vitrectomy between November 1, 2009, and January 1, 2015 at the LAC + USC (Los Angeles County + University of Southern California) Medical Center. RESULTS: A total of 403 eyes with diabetic tractional retinal detachment in 359 patients were included. Successful reattachment of the retina was achieved in 87.6% of eyes after one surgery and 92.6% of eyes at the final follow-up. Best-corrected visual acuity at the final follow-up improved two or more lines in 56.3% of eyes, was stable in 23.8% of eyes, and decreased two or more lines in 19.9% of eyes. Eyes repaired with 23-gauge and 25-gauge vitrectomy systems had similar success rates as eyes treated with 20-gauge instrumentation (P = 0.73). Eyes receiving silicone oil tamponade had lower single-surgery reattachment rates (77.6% vs. 87.6%; P = 0.013), lower reattachment rates at the final follow-up (85.7% vs. 92.6%; P = 0.048), and higher rates of vision loss (34.7% vs. 19.9%; P < 0.0001) but were more likely to have concurrent rhegmatogenous detachment (47.0% vs. 21.3%; P < 0.0001) and macula involving detachment (74.5% vs. 60.0%; P < 0.0001). CONCLUSION: In this large, single-center retrospective study of patients with advanced diabetic tractional retinal detachment, vitrectomy achieved excellent anatomical outcome and improved or stabilized vision in 80.1% of eyes. Smaller gauge vitrectomy systems were found to have similar outcomes to 20-gauge instrumentation.


Asunto(s)
Retinopatía Diabética/complicaciones , Desprendimiento de Retina/cirugía , Vitrectomía/métodos , Adulto , Anciano , Retinopatía Diabética/patología , Retinopatía Diabética/fisiopatología , Femenino , Humanos , Mácula Lútea/patología , Masculino , Persona de Mediana Edad , Desprendimiento de Retina/patología , Desprendimiento de Retina/fisiopatología , Estudios Retrospectivos , Agudeza Visual/fisiología
18.
Ophthalmology ; 123(10S): S89-S97, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27664290

RESUMEN

This article describes the history of visual prostheses, with emphasis on the development of the Argus II retinal prosthesis system (Second Sight Medical Products, Inc., Sylmar, CA). A brief overview of cortical electrical stimulation in the blind is provided, followed by an account of the design and development of retinal stimulation equipment at the Duke Eye Center in the late 1980s; the first human intraoperative tests there and the subsequent 8 years of tests at the Wilmer Eye Institute; the transfer of the project to the Doheny Eye Institute at the University of Southern California and the founding of Second Sight Medical Products; and the development and clinical trials of the Argus I and Argus II systems. In a series of vignettes, we pay tribute to the many colleagues and patient volunteers without whose help the work would not have been possible.

19.
Ophthalmology ; 123(10): 2248-54, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27453256

RESUMEN

PURPOSE: The Argus II Retinal Prosthesis System (Second Sight Medical Products, Inc, Sylmar, CA) was developed to restore some vision to patients blind as a result of retinitis pigmentosa (RP) or outer retinal degeneration. A clinical trial was initiated in 2006 to study the long-term safety and efficacy of the Argus II System in patients with bare or no light perception resulting from end-stage RP. DESIGN: Prospective, multicenter, single-arm clinical trial. Within-patient controls included the nonimplanted fellow eye and patients' native residual vision compared with their vision with the Argus II. PARTICIPANTS: Thirty participants in 10 centers in the United States and Europe. METHODS: The worse-seeing eye of blind patients was implanted with the Argus II. Patients wore glasses mounted with a small camera and a video processor that converted images into stimulation patterns sent to the electrode array on the retina. MAIN OUTCOME MEASURES: The primary outcome measures were safety (the number, seriousness, and relatedness of adverse events) and visual function, as measured by 3 computer-based, objective tests. Secondary measures included functional vision performance on objectively scored real-world tasks. RESULTS: Twenty-four of 30 patients remained implanted with functioning Argus II Systems at 5 years after implantation. Only 1 additional serious adverse event was experienced after the 3-year time point. Patients performed significantly better with the Argus II on than off on all visual function tests and functional vision tasks. CONCLUSIONS: The 5-year results of the Argus II trial support the long-term safety profile and benefit of the Argus II System for patients blind as a result of RP. The Argus II is the first and only retinal implant to have market approval in the European Economic Area, the United States, and Canada.


Asunto(s)
Ceguera/cirugía , Retina/patología , Retinitis Pigmentosa/complicaciones , Agudeza Visual , Prótesis Visuales , Personas con Daño Visual/rehabilitación , Adulto , Anciano , Ceguera/etiología , Ceguera/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Retina/fisiopatología , Retinitis Pigmentosa/fisiopatología , Retinitis Pigmentosa/cirugía , Factores de Tiempo , Resultado del Tratamiento
20.
Graefes Arch Clin Exp Ophthalmol ; 254(8): 1553-1565, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27335025

RESUMEN

PURPOSE: A subretinal implant termed CPCB-RPE1 is currently being developed to surgically replace dystrophic RPE in patients with dry age-related macular degeneration (AMD) and severe vision loss. CPCB-RPE1 is composed of a terminally differentiated, polarized human embryonic stem cell-derived RPE (hESC-RPE) monolayer pre-grown on a biocompatible, mesh-supported submicron parylene C membrane. The objective of the present delivery study was to assess the feasibility and 1-month safety of CPCB-RPE1 implantation in Yucatán minipigs, whose eyes are similar to human eyes in size and gross retinal anatomy. METHODS: This was a prospective, partially blinded, randomized study in 14 normal-sighted female Yucatán minipigs (aged 2 months, weighing 24-35 kg). Surgeons were blinded to the randomization codes and postoperative and post-mortem assessments were performed in a blinded manner. Eleven minipigs received CPCB-RPE1 while three control minipigs underwent sham surgery that generated subretinal blebs. All animals except two sham controls received combined local (Ozurdex™ dexamethasone intravitreal implant) and systemic (tacrolimus) immunosuppression or local immunosuppression alone. Correct placement of the CPCB-RPE1 implant was assessed by in vivo optical coherence tomography and post-mortem histology. hESC-RPE cells were identified using immunohistochemistry staining for TRA-1-85 (a human marker) and RPE65 (an RPE marker). As the study results of primary interest were nonnumerical no statistical analysis or tests were conducted. RESULTS: CPCB-RPE1 implants were reliably placed, without implant breakage, in the subretinal space of the minipig eye using surgical techniques similar to those that would be used in humans. Histologically, hESC-RPE cells were found to survive as an intact monolayer for 1 month based on immunohistochemistry staining for TRA-1-85 and RPE65. CONCLUSIONS: Although inconclusive regarding the necessity or benefit of systemic or local immunosuppression, our study demonstrates the feasibility and safety of CPCB-RPE1 subretinal implantation in a comparable animal model and provides an encouraging starting point for human studies.


Asunto(s)
Células Madre Embrionarias Humanas/trasplante , Degeneración Macular/cirugía , Epitelio Pigmentado de la Retina/trasplante , Trasplante de Células Madre/métodos , Animales , Células Cultivadas , Modelos Animales de Enfermedad , Estudios de Factibilidad , Femenino , Humanos , Degeneración Macular/diagnóstico , Estudios Prospectivos , Epitelio Pigmentado de la Retina/citología , Porcinos , Porcinos Enanos , Tomografía de Coherencia Óptica , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA