Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 131
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Europace ; 26(9)2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39230049

RESUMEN

AIMS: Atrial fibrosis and autonomic remodelling are proposed pathophysiological mechanisms in atrial fibrillation (AF). Their impact on conduction velocity (CV) dynamics and wavefront propagation was evaluated. METHODS AND RESULTS: Local activation times (LATs), voltage, and geometry data were obtained from patients undergoing ablation for persistent AF. LATs were obtained at three pacing intervals (PIs) in sinus rhythm (SR). LATs were used to determine CV dynamics and their relationship to local voltage amplitude. The impact of autonomic modulation- pharmacologically and with ganglionated plexi (GP) stimulation, on CV dynamics, wavefront propagation, and pivot points (change in wavefront propagation of ≥90°) was determined in SR. Fifty-four patients were included. Voltage impacted CV dynamics whereby at non-low voltage zones (LVZs) (≥0.5 mV) the CV restitution curves are steeper [0.03 ± 0.03 m/s ΔCV PI 600-400 ms (PI1), 0.54 ± 0.09 m/s ΔCV PI 400-250 ms (PI2)], broader at LVZ (0.2-0.49 mV) (0.17 ± 0.09 m/s ΔCV PI1, 0.25 ± 0.11 m/s ΔCV PI2), and flat at very LVZ (<0.2 mV) (0.03 ± 0.01 m/s ΔCV PI1, 0.04 ± 0.02 m/s ΔCV PI2). Atropine did not change CV dynamics, while isoprenaline and GP stimulation resulted in greater CV slowing with rate. Isoprenaline (2.7 ± 1.1 increase/patient) and GP stimulation (2.8 ± 1.3 increase/patient) promoted CV heterogeneity, i.e. rate-dependent CV (RDCV) slowing sites. Most pivot points co-located to RDCV slowing sites (80.2%). Isoprenaline (1.3 ± 1.1 pivot increase/patient) and GP stimulation (1.5 ± 1.1 increase/patient) also enhanced the number of pivot points identified. CONCLUSION: Atrial CV dynamics is affected by fibrosis burden and influenced by autonomic modulation which enhances CV heterogeneity and distribution of pivot points. This study provides further insight into the impact of autonomic remodelling in AF.


Asunto(s)
Fibrilación Atrial , Fibrosis , Atrios Cardíacos , Humanos , Femenino , Masculino , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Persona de Mediana Edad , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/inervación , Anciano , Potenciales de Acción , Ablación por Catéter , Remodelación Atrial , Frecuencia Cardíaca , Técnicas Electrofisiológicas Cardíacas , Sistema Nervioso Autónomo/fisiopatología , Función del Atrio Izquierdo , Isoproterenol/farmacología , Atropina/farmacología , Factores de Tiempo , Sistema de Conducción Cardíaco/fisiopatología , Resultado del Tratamiento
2.
Europace ; 26(10)2024 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-39283961

RESUMEN

AIMS: Pathophysiology of atrial fibrillation (AF) remains unclear. Interactions between scar and conduction velocity (CV) and their impact on wavefront propagation in sinus rhythm (SR) and rotational activity burden in AF were evaluated. METHODS AND RESULTS: Local activation times (LATs) and voltage data were obtained from patients undergoing ablation for persistent AF. Omnipolar voltage (OV) and bipolar voltage (BV) data were obtained during AF and SR at pacing intervals of 600 and 250 ms. Local activation times were used to determine CV dynamics and their relationship to the underlying voltage and pivot points in SR. Computational modelling studies were performed to evaluate the impact of CVs and fibrosis on rotational activity burden in AF. Data from 60 patients with a total of 2 768 400 LAT and voltage points were analysed (46 140 ± 5689 points/patient). Voltage determined CV dynamics. Enhanced CV heterogeneity sites were predominantly mapped to low-voltage zones (LVZs) (0.2-0.49 mV) (128/168, 76.2%) rather than LVZs (<0.2 mV) and frequently co-located to pivot points (151/168, 89.9%). Atrial fibrillation OV maps correlated better with SR BV 250 ms than 600 ms maps, thereby representing fixed and functional remodelling. Sinus rhythm maps at 250 ms compared with 600 ms harboured a greater number of pivot points. Increased CV slowing and functional remodelling on computational models resulted in a greater rotational activity burden. CONCLUSION: Conduction velocity dynamics are impacted by the degree of scar. Conduction velocity heterogeneity and functional remodelling impacts wavefront propagation in SR and rotational activity burden in AF. This study provides insight into the pathophysiology of AF and identifies potential novel ablation targets.


Asunto(s)
Fibrilación Atrial , Remodelación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Femenino , Masculino , Persona de Mediana Edad , Anciano , Potenciales de Acción , Modelos Cardiovasculares , Frecuencia Cardíaca , Sistema de Conducción Cardíaco/fisiopatología , Técnicas Electrofisiológicas Cardíacas , Fibrosis , Simulación por Computador , Cicatriz/fisiopatología
3.
Pacing Clin Electrophysiol ; 47(11): 1499-1502, 2024 Nov.
Artículo en Español | MEDLINE | ID: mdl-38874349

RESUMEN

We describe two cases of secondary prevention subcutaneous implantable cardioverter defibrillator (S-ICD) implantation and subsequent S-ICD electrode displacement which initially went undetected. One presentation was a result of a coincidental chest x-ray for respiratory exacerbation and another with an untreated episode highlighted via remote monitoring, both patients were booked to clinic for further investigation. Our findings highlighted had there been a comparison of the existing subcutaneous electrogram (S-ECG) to captured S-ECGs at time of implant the electrode displacement would have been detected beforehand. This underpins the importance of introducing the simple management strategy into routine follow-up.


Asunto(s)
Desfibriladores Implantables , Humanos , Masculino , Persona de Mediana Edad , Electrocardiografía , Electrodos Implantados , Falla de Equipo , Femenino , Anciano
4.
Pacing Clin Electrophysiol ; 47(10): 1404-1411, 2024 10.
Artículo en Inglés | MEDLINE | ID: mdl-39107948

RESUMEN

BACKGROUND: When using lesion size index (LSI) to guide catheter ablation, it is unclear what combination of power, contact force and time would be preferable to use and what LSI target value to aim for. This study aimed at identifying desirable ablation settings and LSI targets by using tissue impedance drop as indicator of lesion formation. METHODS: Consecutive patients, undergoing their first left atrial (LA) catheter ablation for atrial fibrillation, with radiofrequency energy (RF) powers of 20, 30 and 40 W were enrolled. Tissue impedance, contact force (CF), Force Time Integral (FTI) and LSI values were continuously recorded during ablation and sampled at 100 Hz. Mean CF and Contact Force Variability (CFV) were calculated for every lesion. The effect of RF power, ablation time, CF and CFV on impedance drop and LSI were assessed. RESULTS: A total of 3258 lesions were included in the analysis. For any target LSI value, use of higher RF powers translated into progressively higher impedance drops. The impact of lower CF and higher CFV on impedance drop was more relevant when using lower powers. Target LSI values corresponding to maximum impedance drop were identified depending on RF power, mean CF and CFV used. CONCLUSIONS: Even in the context of an LSI-guided ablation strategy, use of lower or higher powers might lead to different lesion sizes. Different LSI targets might be needed depending on the combination of RF power, CF and CFV used for ablation. Incorporating indicators of catheter stability, like CFV, in the LSI formula could improve the predictive value of LSI for lesion size. Studies with clinical outcomes are required to confirm the clinical relevance of these findings.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Impedancia Eléctrica , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Ablación por Catéter/métodos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Resultado del Tratamiento
5.
J Cardiovasc Electrophysiol ; 34(5): 1141-1151, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36808788

RESUMEN

INTRODUCTION: Preliminary data suggest that high power short duration (HPSD) ablation for pulmonary vein isolation (PVI) are safe. Limited data are available on its effectiveness. Aim was to evaluate HPSD ablation in atrial fibrillation ablation using a novel Qdot Micro catheter. METHODS AND RESULTS: Prospective multicenter study evaluating safety and efficacy of PVI with HPSD ablation. First pass isolation (FPI) and sustained PVI was assessed. If FPI was not achieved additional ablation index (AI)-guided ablation with 45 W was performed and metrics predictive of this were determined. Sixty-five patients and 260 veins were treated. Procedural and LA dwell time was 93.9 ± 30.4 and 60.5 ± 23.1 min, respectively. FPI was achieved in 47 (72.3%) patients and 231 veins (88.8%) with an ablation duration of 4.6 ± 1.0 min. Twenty-nine veins required additional AI-guided ablation to achieve initial PVI with 24 anatomical sites ablated with the right posterior carina being the most common site (37.5%). A contact force of ≥8 g (area under the curve [AUC]: 0.81; p < 0.001) and catheter position variation of ≤1.2 mm (AUC: 0.79; p < 0.001) with HPSD were strongly predictive of not requiring additional AI-guided ablation. Out of the 260 veins, only 5 (1.9%) veins showed acute reconnection. HPSD ablation was associated with shorter procedure times (93.9 vs. 159.4 min; p < 0.001), ablation times (6.1 vs. 27.7 min; p < 0.001), and lower rates of PV reconnection (9.2% vs. 30.8%; p = 0.004) compared to moderate power cohort. CONCLUSIONS: HPSD ablation is an effective ablation modality which results in effective PVI whilst maintaining a safety profile. Its superiority needs to be evaluated in randomized controlled trials.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Frecuencia Cardíaca , Venas Pulmonares/cirugía , Estudios Prospectivos , Catéteres , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento , Recurrencia
6.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37213071

RESUMEN

AIMS: Arrhythmogenic right ventricular cardiomyopathy (ARVC) patients develop ventricular arrhythmias (VAs) responsive to anti-tachycardia pacing (ATP). However, VA episodes have not been characterized in accordance with the device therapy, and with the emergence of the subcutaneous implantable cardioverter defibrillator (S-ICD), the appropriate device prescription in ARVC remains unclear. Study aim was to characterize VA events in ARVC patients during follow-up in accordance with device therapy and elicit if certain parameters are predictive of specific VA events. METHODS AND RESULTS: This was a retrospective single-centre study utilizing prospectively collated registry data of ARVC patients with ICDs. Forty-six patients were included [54.0 ± 12.1 years old and 20 (43.5%) secondary prevention devices]. During a follow-up of 12.1 ± 6.9 years, 31 (67.4%) patients had VA events [n = 2, 6.5% ventricular fibrillation (VF), n = 14], 45.2% VT falling in VF zone resulting in ICD shock(s), n = 10, 32.3% VT resulting in ATP, and n = 5, 16.1% patients had both VT resulting in ATP and ICD shock(s). Lead failure rates were high (11/46, 23.9%). ATP was successful in 34.5% of patients. Severely impaired right ventricular (RV) function was an independent predictor of VT resulting in ATP (hazard ratio 16.80, 95% confidence interval 3.74-75.2; P < 0.001) with a high predictive accuracy (area under the curve 0.88, 95%CI 0.76-1.00; P < 0.001). CONCLUSION: VA event rates are high in ARVC patients with a majority having VT falling in the VF zone resulting in ICD shock(s). S-ICDs could be of benefit in most patients with ARVC with the absence of severely impaired RV function which has the potential to avoid consequences of the high burden of lead failure.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Cardiomiopatías , Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Adulto , Persona de Mediana Edad , Anciano , Desfibriladores Implantables/efectos adversos , Estudios Retrospectivos , Función Ventricular Derecha , Estudios de Seguimiento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/prevención & control , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/prevención & control , Arritmias Cardíacas/etiología , Cardiomiopatías/complicaciones , Adenosina Trifosfato , Displasia Ventricular Derecha Arritmogénica/complicaciones , Displasia Ventricular Derecha Arritmogénica/diagnóstico , Displasia Ventricular Derecha Arritmogénica/terapia
7.
Europace ; 25(11)2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37738643

RESUMEN

AIMS: Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation (AF). There are limited data on the PolarX Cryoballoon. The study aimed to establish the safety, efficacy, and feasibility of same day discharge for Cryoballoon PVI. METHODS AND RESULTS: Multi-centre study across 12 centres. Procedural metrics, safety profile, and procedural efficacy of the PolarX Cryoballoon with the Arctic Front Advance (AFA) Cryoballoon were compared in a cohort large enough to provide definitive comparative data. A total of 1688 patients underwent PVI with cryoablation (50% PolarX and 50% AFA). Successful PVI was achieved with 1677 (99.3%) patients with 97.2% (n = 1641) performed as day case procedures with a complication rate of <1%. Safety, procedural metrics, and efficacy of the PolarX Cryoballoon were comparable with the AFA cohort. The PolarX Cryoballoon demonstrated a nadir temperature of -54.6 ± 7.6°C, temperature at 30 s of -38.6 ± 7.2°C, time to -40°C of 34.1 ± 13.7 s, and time to isolation of 49.8 ± 33.2 s. Independent predictors for achieving PVI included time to reach -40°C [odds ratio (OR) 1.34; P < 0.001] and nadir temperature (OR 1.24; P < 0.001) with an optimal cut-off of ≤34 s [area under the curve (AUC) 0.73; P < 0.001] and nadir temperature of ≤-54.0°C (AUC 0.71; P < 0.001), respectively. CONCLUSIONS: This large-scale UK multi-centre study has shown that Cryoballoon PVI is a safe, effective day case procedure. PVI using the PolarX Cryoballoon was similarly safe and effective as the AFA Cryoballoon. The cryoablation metrics achieved with the PolarX Cryoballoon were different to that reported with the AFA Cryoballoon. Modified cryoablation targets are required when utilizing the PolarX Cryoballoon.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Criocirugía/métodos , Resultado del Tratamiento , Factores de Tiempo , Venas Pulmonares/cirugía , Ablación por Catéter/métodos , Reino Unido , Recurrencia
8.
J Cardiovasc Electrophysiol ; 33(10): 2139-2151, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35775822

RESUMEN

INTRODUCTION: Markers predicting atrial fibrillation (AF) termination and freedom from AF/atrial tachycardia (AT) has been proposed. This study aimed to evaluate the role of novel coronary sinus (CS) electrogram characteristics in predicting the acute ablation response and freedom from AF/AT during follow-up. METHODS: Patients undergoing ablation for persistent AF as part of the Stochastic Trajectory Analysis of Ranked signals mapping study were included. Novel CS electrogram characteristics including CS cycle length variability (CLV) and CS activation pattern stability (APS) and proportion of low voltage zones (LVZs) were reviewed as potential predictors for AF termination on ablation and freedom from AF/AT during follow-up. The relationship between localized driver characteristics and CS electrogram characteristics was also assessed. RESULTS: Sixty-five patients were included. AF termination was achieved in 51 patients and 80% of patients were free from AF/AT during a follow-up of 29.5 ± 3.7 months. CS CLV of <30 ms, CS APS of ≥30% and proportion of LVZ < 30% showed high diagnostic accuracy in predicting AF termination on ablation and freedom from AF/AT during follow-up (CS CLV odds ratio [OR] 25.6, area under the curve [AUC] 0.91; CS APS OR 15.9, AUC 0.94; proportion of LVZs OR 21.4, AUC 0.88). These markers were independent predictors of AF termination on ablation and AF/AT recurrence during follow-up. Ablation of a smaller number of drivers that demonstrate greater dominance strongly correlate with greater CS organization. CONCLUSION: Novel CS electrogram characteristics were independent predictors of AF termination and AF/AT recurrence during follow-up. These markers can potentially aid in predicting outcomes and guide ablation and follow-up strategies.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Seno Coronario , Venas Pulmonares , Taquicardia Supraventricular , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Seno Coronario/cirugía , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
9.
J Cardiovasc Electrophysiol ; 33(3): 510-526, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34921464

RESUMEN

INTRODUCTION: Ethanol ablation (EA) is an alternative option for subjects with ventricular arrhythmias (VAs) refractory to conventional medical and ablative treatment. However, data on the efficacy and safety of EA remain sparse. METHODS: A systematic literature search was conducted. The primary outcomes were 1) freedom from the targeted VA and 2) freedom from any VAs post-EA. Additional safety outcomes were also analyzed. RESULTS: Ten studies were selected accounting for a population of 174 patients (62.3 ± 12.5 years, 94% male) undergoing 185 procedures. The overall acute success rate of EA was 72.4% (confidence interval [CI95% ]: 65.6-78.4). After a mean follow-up of 11.3 ± 5.5 months, the incidence of relapse of the targeted VA was 24.4% (CI95% : 17.1-32.8), while any VAs post-EA occurred in 41.3% (CI95% : 33.7-49.1). The overall incidence of procedural complications was 14.1% (CI95% : 9.8-19.8), with pericardial complications and complete atrioventricular block being the most frequent. An anterograde transarterial approach was associated with a higher rate of VA recurrences and complications compared to a retrograde transvenous route; however, differences in the baseline population characteristics and in the targeted ventricular areas should be accounted. CONCLUSION: EA is a valuable therapeutic option for VAs refractory to conventional treatment and can result in 1-year freedom from VA recurrence in 60%-75% of the patients. However, anatomical or technical challenges preclude acute success in almost 30% of the candidates and the rate of complication is not insignificant, highlighting the importance of well-informed patient selection. The certainty of the evidence is low, and further research is necessary.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirugía , Ablación por Catéter/efectos adversos , Etanol/efectos adversos , Femenino , Ventrículos Cardíacos , Humanos , Masculino , Estudios Retrospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
10.
J Cardiovasc Electrophysiol ; 33(11): 2263-2273, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35924481

RESUMEN

BACKGROUND: This prospective trial sought to phenotype persistent atrial fibrillation (AF) based on AF mechanisms using electrocardiographic imaging (ECGI) mapping to determine whether this would predict long-term freedom from arrhythmia after pulmonary vein isolation (PVI). METHODS: Patients with persistent AF of <2 years duration underwent cryoballoon PVI. ECGI mapping was performed before PVI to determine potential drivers (PDs) defined as rotational activations completing ≥1.5 revolutions or focal activations. The coprimary endpoint was the association between (1) PD burden (defined as the number of PD occurrences) and (2) PD distribution (defined as the number of segments on an 18-segment model of the atria harboring PDs) with freedom from arrhythmia at 1-year follow up. RESULTS: Of 100 patients, 97 completed follow up and 52 (53.6%) remained in sinus rhythm off antiarrhythmic drugs. Neither PD burden nor PD distribution predicted freedom from arrhythmia (hazard ratio [HR]: 1.01, 95% confidence interval [CI]: 0.99-1.03, p = .164; and HR: 1.04, 95% CI: 0.91-1.17, p = .591, respectively). Otherwise, the burden of rotational PDs, rotational stability, and the burden of PDs occurring at the pulmonary veins and posterior wall all failed to predict arrhythmia recurrence (all p > .10). CONCLUSIONS: AF mechanisms as determined using ECGI mapping do not predict outcomes after PVI for persistent AF. Further studies using different methodologies to characterize AF mechanisms are warranted (NCT03394404).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Estudios Prospectivos , Recurrencia , Resultado del Tratamiento , Electrocardiografía , Fenotipo , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
11.
Europace ; 24(11): 1824-1833, 2022 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-35894862

RESUMEN

AIMS: To determine the incidence, clinical features, management, and outcomes of pacemaker (PM) and implantable cardioverter-defibrillator (ICD) lead cardiac perforation. Cardiac perforations due to PM and ICD leads are rare but serious complications. Clinical features vary widely and may cause diagnostic delay. Management strategies are non-guideline based due to paucity of data. METHODS AND RESULTS: A multicentre retrospective series including 3 UK cardiac tertiary centres from 2016 to 2020. Patient, device, and lead characteristics were obtained including 6-month outcomes. Seventy cases of perforation were identified from 10 631 procedures; perforation rate was 0.50% for local implants. Thirty-nine (56%) patients were female, mean ( ± standard deviation) age 74 ( ± 13.8) years. Left ventricular ejection fraction 51 ( ± 13.2) %. Median time to diagnosis was 9 (range: 0-989) days. Computed tomography (CT) diagnosed perforation with 97% sensitivity. Lead parameter abnormalities were present in 86% (whole cohort) and 98.6% for perforations diagnosed >24 h. Chest pain was the commonest symptom, present in 46%. The management strategy was percutaneous in 98.6% with complete procedural success in 98.6%. Pericardial effusion with tamponade was present in 17% and was associated with significantly increased mortality and major complications. Anticoagulation status was associated with tamponade by multivariate analysis (odds ratio 21.7, 95% confidence interval: 1.7-275.5, P = 0.018). CONCLUSIONS: Perforation was rare (0.50%) and managed successfully by a percutaneous strategy with good outcomes. Tamponade was associated with increased mortality and major complications. Anticoagulation status was an independent predictor of tamponade. Case complexity is highly variable and requires skilled operators with a multi-disciplinary approach to achieve good outcomes.


Asunto(s)
Desfibriladores Implantables , Lesiones Cardíacas , Marcapaso Artificial , Humanos , Femenino , Anciano , Masculino , Estudios Retrospectivos , Volumen Sistólico , Diagnóstico Tardío/efectos adversos , Función Ventricular Izquierda , Marcapaso Artificial/efectos adversos , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia , Desfibriladores Implantables/efectos adversos , Enfermedad Iatrogénica , Anticoagulantes
12.
Europace ; 24(9): 1420-1429, 2022 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-35737685

RESUMEN

AIM: Evaluate the novel PolarX Cryoballoon in atrial fibrillation (AF) catheter ablation through a propensity-matched comparison with the Arctic Front Advance (AFA). The aim was also to identify cryoablation metrics that are predictive of successful pulmonary vein isolation (PVI) with the PolarX Cryoballoon. METHODS AND RESULTS: This prospective multi-centre study included patients that underwent cryoablation for AF. All patients underwent PVI with reconnection assessed after a 30-min waiting period and adenosine. Safety, efficacy, and cryoablation metrics were compared between PolarX and a propensity-matched AFA cohort. Seventy patients were included with 278 veins treated. In total, 359 cryoablations were performed (1.3 ± 0.6 per vein) to achieve initial PVI with 205 (73.7%) veins isolating with a single cryoablation. Independent predictors for achieving initial PVI included temperature at 30 s [odds ratio (OR) 1.26; P = 0.003] and time to reach -40°C (OR 1.88; P < 0.001) with an optimal cut-off of ≤-38.5°C at 30 s [area under the curve (AUC) 0.79; P < 0.001] and ≤-40°C at ≤32.5 s (AUC 0.77; P < 0.001), respectively. Of the 278 veins, 46 (16.5%) veins showed acute reconnection. Temperature at 30 s (≤-39.5°C, OR 1.24; P = 0.002), nadir temperature (≤-53.5°C, OR 1.35; P = 0.003), and time to isolation (≤38.0 s, OR 1.18; P = 0.009) were independent predictors of sustained PVI. Combining two of these three targets was associated with reconnection in only 2-5% of PVs. Efficacy and safety of the PolarX Cryoballoon were comparable to AFA Cryoballoon, however, cryoablation metrics were significantly different. CONCLUSIONS: The PolarX Cryoballoon has a different cryoablation profile to AFA Cryoballoon. Prospective testing of these proposed targets in large outcomes studies is required.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Adenosina , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Benchmarking , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Humanos , Estudios Prospectivos , Venas Pulmonares/cirugía , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
13.
Pacing Clin Electrophysiol ; 45(3): 365-373, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35023176

RESUMEN

BACKGROUND: The risk factors for developing pacing induced left ventricular dysfunction (LVD) in patients with high burden of right ventricular pacing (RVP) is poorly understood. Therefore, in the present study, we aimed to assess the determinants of pacing induced LVD. METHODS: Our data were retrospectively collected from 146 patients with RVP > 40% who underwent generator change (GC) or cardiac resynchronization therapy (CRT) upgrade between 2016 and 2019 who had left ventricular ejection fraction (EF) ≥50% at initial implant. RESULTS: A total of 75 patients had CRT upgrade due to pacing induced LVD (EF < 50%) and 71 patients with preserved LV function (EF ≥ 50%) had a GC. Primary indication for pacing in both groups was complete heart block. Male predominance (p = .008), prior myocardial infarction (MI) (p = .001), atrial fibrillation (AF) (p = .009), chronic kidney disease (CKD) (p = .005), and borderline low systolic function (BLSF) (EF 50%-55%) (p = .04) were more prevalent in the CRT upgrade group. Presence of AF (odds ratio [OR] = 3.05, 95% confidence interval [CI] 1.42-6.58; p = .004), BLSF (OR = 3.8, 95% CI 1.22-11.8; p = .02), and male gender (OR = 2.41, 95% CI 1.14-5.08; p = .02) were independent predictors for RVP induced LVD. Age (OR = 1.08, 95% CI 1.02-1.14; p = .005) and BLSF (OR = 5.33, 95% CI 1.26-22.5; p = .023) were independent predictors of earlier development of LVD after implant. CONCLUSIONS: Our results suggested that AF, BLSF, and male gender are predictors for development of pacing induced LVD in patients with high RVP burden. LVD can occur at any time after pacemaker implant with BLSF and increasing age associated with earlier development of LVD.


Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Disfunción Ventricular Izquierda , Fibrilación Atrial/terapia , Estimulación Cardíaca Artificial/métodos , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Femenino , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Estudios Retrospectivos , Factores de Riesgo , Volumen Sistólico , Resultado del Tratamiento , Reino Unido/epidemiología , Función Ventricular Izquierda
14.
J Cardiovasc Electrophysiol ; 32(2): 200-209, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33368766

RESUMEN

INTRODUCTION: The optimal ablation approach for persistent atrial fibrillation (AF) remains unclear. METHODS AND RESULTS: Objective was to compare the long-term rates of freedom from AF/AT in patients that underwent STAR mapping guided ablation against outcomes of patients undergoing conventional ablation procedures. Patients undergoing ablation for persistent AF as part of the Stochastic Trajectory Analysis of Ranked signals (STAR) mapping study were included. Outcomes following 'pulmonary vein isolation (PVI) plus STAR mapping guided ablation (STAR mapping cohort) were compared to patients undergoing PVI alone ablation during the same time period and also a propensity-matched cohort undergoing PVI plus the addition of complex fractionated electrogram (CFAE) and/or linear ablation ("conventional ablation"). Rates of procedural AF termination and freedom from AF/AT during follow-up were compared. Sixty-five patients were included in both the STAR cohort and propensity matched conventional ablation cohort. AF termination rates were significantly higher in the STAR cohort (51/65, 78.5%) than conventional ablation cohort (10/65, 15.4%) and PVI alone ablation cohort (13/50, 26.0%; STAR cohort vs. other 2 cohorts both p < .001). There was no significant difference in procedure time between the three cohorts. During ≥20 months follow-up a lower proportion of patients had AF/AT recurrence in the STAR cohort (20.0%) compared with the conventional ablation cohort (50.8%) or the PVI alone ablation cohort (50.0%; both p < .05 compared to STAR cohort). CONCLUSIONS: Outcomes of PVI plus STAR mapping guided ablation was superior to PVI alone or in combination with linear/CFAE ablation. A multicenter randomized controlled trial is planned to confirm these findings.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
15.
J Cardiovasc Electrophysiol ; 32(4): 925-930, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33590568

RESUMEN

INTRODUCTION: Cryoballoon ablation is an established technique to achieve pulmonary vein isolation in patients with atrial fibrillation (AF). Recently, a new manufacturer of cryoballoon achieved regulatory CE marking (POLARx™; Boston Scientific). We describe our early experience of using this new market entrant of the technology and describe procedural aspects in comparison to the incumbent Medtronic Arctic Front Advance™. METHODS: We assessed the first 40 AF ablations performed with the POLARx catheter at the Barts Heart Centre. These patients were compared with a contemporaneous series of patients undergoing ablation by the same operators using the Arctic Front Advance. Procedural metrics were prospectively recorded. RESULTS: A total of four operators undertook 40 cases using the POLARx catheter, compared with 40 cases using the Arctic Front Advance. Procedure times (60.0 vs. 60.0 min) were similar between the two technologies, however left atrial dwell time (35.0 vs 39.0 min) and fluoroscopy times (3.3 vs. 5.2 min) were higher with the POLARx. Measured nadir and isolation balloon temperatures were significantly lower with POLARx. Almost all veins were isolated with a median freezing time of 16.0 (POLARx) versus 15.0 (Arctic Front Advance) min. The rate of procedural complications was low in both groups. CONCLUSION: The POLARx cryoballoon is effective for pulmonary vein isolation. Measured isolation and nadir temperatures are lower compared with the predicate Arctic Front Advance catheter. The technology appears similar in acute efficacy and has a short learning curve, but formal dosing studies may be required to prove equivalence of efficacy.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Fluoroscopía , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Tecnología , Resultado del Tratamiento
16.
Europace ; 23(9): 1409-1417, 2021 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-33930121

RESUMEN

AIMS: Atrial fibrillation (AF) is common in hypertrophic cardiomyopathy (HCM). Data on the efficacy of catheter ablation of AF in HCM patients are sparse. METHODS AND RESULTS: Observational multicentre study in 137 HCM patients (mean age 55.0 ± 13.4, 29.1% female; 225 ablation procedures). We investigated (i) the efficacy of catheter ablation for AF beyond the initial 12 months; (ii) the available risk scores, stratification schemes and genotype as potential predictors of arrhythmia relapse, and (iii) the impact of cryoballoon vs. radiofrequency in procedural outcomes. Mean follow-up was 43.8 ± 37.0 months. Recurrences after the initial 12-month period post-ablation were frequent, and 24 months after the index procedure, nearly all patients with persistent AF had relapsed, and only 40% of those with paroxysmal AF remained free from arrhythmia recurrence. The APPLE score demonstrated a modest discriminative capacity for AF relapse post-ablation (c-statistic 0.63, 95% CI 0.52-0.75; P = 0.022), while the risk stratification schemes for sudden death did not. On multivariable analysis, left atrium diameter and LV apical aneurysm were independent predictors of recurrence. Fifty-eight patients were genotyped; arrhythmia-free survival was similar among subjects with different gene mutations. Rate of procedural complications was high (9.3%), although reducing over time. Outcome for cryoballoon and radiofrequency ablation was comparable. CONCLUSION: Very late AF relapses post-ablation is common in HCM patients, especially in those with persistent AF. Left atrium size, LV apical aneurysm, and the APPLE score might contribute to identify subjects at higher risk of arrhythmia recurrence. First-time cryoballoon is comparable with radiofrequency ablation.


Asunto(s)
Fibrilación Atrial , Cardiomiopatía Hipertrófica , Ablación por Catéter , Criocirugía , Adulto , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico , Cardiomiopatía Hipertrófica/cirugía , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Femenino , Atrios Cardíacos , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Resultado del Tratamiento
17.
Europace ; 23(1): 104-112, 2021 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-33083830

RESUMEN

AIMS: Optimum timing of pacemaker implantation following cardiac surgery is a clinical challenge. European and American guidelines recommend observation, to assess recovery of atrioventricular block (AVB) (up to 7 days) and sinus node (5 days to weeks) after cardiac surgery. This study aims to determine rates of cardiac implantable electronic devices (CIEDs) implants post-surgery at a high-volume tertiary centre over 3 years. Implant timing, patient characteristics and outcomes at 6 months including pacemaker utilization were assessed. METHODS AND RESULTS: All cardiac operations (n = 5950) were screened for CIED implantation following surgery, during the same admission, from 2015 to 2018. Data collection included patient, operative, and device characteristics; pacing utilization and complications at 6 months. A total of 250 (4.2%) implants occurred; 232 (3.9%) for bradycardia. Advanced age, infective endocarditis, left ventricle systolic impairment, and valve surgery were independent predictors for CIED implants (P < 0.0001). Relative risk (RR) of CIED implants and proportion of AVB increased with valve numbers operated (single-triple) vs. non-valve surgery: RR 5.4 (95% CI 3.9-7.6)-21.0 (11.4-38.9) CIEDs. Follow-up pacing utilization data were available in 91%. Significant utilization occurred in 82% and underutilization (<1% A and V paced) in 18%. There were no significant differences comparing utilization rates in early (≤day 5 post-operatively) vs. late implants (P = 0.55). CONCLUSION: Multi-valve surgery has a particularly high incidence of CIED implants (14.9% double, 25.6% triple valve). Age, left ventricle systolic impairment, endocarditis, and valve surgery were independent predictors of CIED implants. Device underutilization was infrequent and uninfluenced by implant timing. Early implantation (≤5 days) should be considered in AVB post-multi-valve surgery.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Desfibriladores Implantables , Marcapaso Artificial , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Desfibriladores Implantables/efectos adversos , Electrónica , Humanos , Marcapaso Artificial/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
18.
Pacing Clin Electrophysiol ; 44(6): 1039-1046, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33782987

RESUMEN

BACKGROUND: Anatomical studies demonstrate significant variation in cavotricuspid isthmus (CTI) architecture. METHODS: Thirty-eight patients underwent CTI ablation at two tertiary centers. Operators delivered 682 lesions with a target ablation index (AI) of 600 Wgs. Ablation parameters were recorded every 10-20 ms. Post hoc, Visitags were trisected according to CTI position: inferior vena cava (IVC), middle (Mid), or ventricular (V) lesions. RESULTS: There were no complications. 92.1% of patients (n = 35) remained in sinus rhythm after 14.6 ± 3.4 months. For the whole CTI, peak AI correlated with mean impedance drop (ID) (R2  = 0.89, p < .0001). However, analysis by anatomical site demonstrated a non-linear relationship Mid CTI (R2  = 0.15, p = .21). Accordingly, while mean AI was highest Mid CTI (IVC: 473.1 ± 122.1 Wgs, Mid: 539.6 ± 103.5 Wgs, V: 486.2 ± 111.8 Wgs, ANOVA p < .0001), mean ID was lower (IVC: 10.7 ± 7.5Ω, Mid: 9.0 ± 6.5Ω, V: 10.9 ± 7.3Ω, p = .011), and rate of ID was slower (IVC: 0.37 ± 0.05 Ω/s, Mid: 0.18 ± 0.08 Ω/s, V: 0.29 ± 0.06 Ω/s, p < .0001). Mean contact force was similar at all sites; however, temporal fluctuations in contact force (IVC: 19.3 ± 12.0 mg/s, Mid: 188.8 ± 92.1 mg/s, V: 102.8 ± 32.3 mg/s, p < .0001) and catheter angle (IVC: 0.42°/s, Mid: 3.4°/s, V: 0.28°/s, p < .0001) were greatest Mid CTI. Use of a long sheath attenuated these fluctuations and improved energy delivery. CONCLUSIONS: Ablation characteristics vary across the CTI. At the Mid CTI, higher AI values do not necessarily deliver more effective ablation; this may reflect localized fluctuations in catheter angle and contact force.


Asunto(s)
Aleteo Atrial/cirugía , Ablación por Catéter/métodos , Válvula Tricúspide/cirugía , Anciano , Femenino , Humanos , Masculino
19.
J Cardiovasc Electrophysiol ; 31(6): 1340-1349, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32219906

RESUMEN

INTRODUCTION: Stochastic trajectory analysis of ranked signals (STAR) mapping has recently been used to ablate persistent atrial fibrillation (AF) with high rates of AF termination and long-term freedom from AF in small, single-arm studies. We hypothesized that rapidity and organization markers would correlate with early sites of activation (ESA). METHODS: Patients undergoing persistent AF ablation as part of the STAR mapping study were included. Five-minute unipolar basket recordings used to create STAR maps were used to determine the minimum-cycle length (Min-CL) and CL variability (CLV) at each electrode to identify the site of the fastest Min-CL and lowest CLV across the left atrium (LA). The location of ESA targeted with ablation was compared with these sites. Dominant frequency was assessed at ESA and compared with that of neighboring electrodes to assess for regional gradients. RESULTS: Thirty-two patients were included with 83 ESA ablated, with an ablation response at 73 sites (24 AF termination and 49 CL slowing ≥30 ms). Out of these, 54 (74.0%) and 56 (76.7%) colocated to sites of fastest Min-CL and lowest CLV, respectively. Regional CL and frequency gradients were demonstrable at majority of ESA. ESA colocating to sites of fastest Min-CL and lowest CLV were more likely to terminate AF with ablation (odds ratio, 34 and 29, respectively, P = .02). These showed a moderate sensitivity (74.0% Min-CL and 75.3% CLV) and specificity (66.7% Min-CL and 76.9% CLV) in predicting ESA with an ablation response. CONCLUSIONS: ESA correlate with rapidity and organization markers. Further work is needed to clarify any role for spectral analysis in prioritizing driver ablation.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Procesamiento de Señales Asistido por Computador , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Toma de Decisiones Clínicas , Humanos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Análisis Espectral , Procesos Estocásticos , Factores de Tiempo , Resultado del Tratamiento
20.
J Cardiovasc Electrophysiol ; 31(8): 2192-2205, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32495462

RESUMEN

AIMS: We sought out to make comparisons between all atrial fibrillation (AF) catheter ablation technologies using randomized controlled trial data. Our comparisons were freedom from AF, procedural duration, and fluoroscopy duration. METHODS: Searches were made of EMBASE, MEDLINE, and CENTRAL databases, and studies were selected which had cryoballoon, conventional radiofrequency (RF), multipolar RF catheters, and laser technology as an arm in the study and were identified as randomized controlled trials (RCTs). These studies were analyzed for direct comparisons using conventional meta-analysis and a combination of indirect and direct comparisons via a network meta-analysis (NMA). RESULTS: With respect to freedom from AF both direct comparisons and NMA did not demonstrate any significant difference. However in analysis of procedural and fluoroscopy duration (minutes) for the pulmonary vein ablation catheter (PVAC), both conventional analysis and NMA revealed significantly shorter procedure times, RF vs PVAC (conventional: 61.99 [38.03-85.94], P <.00001; NMA: 54.76 [36.64-72.88], P < .0001) and fluoroscopy times, RF vs PVAC (conventional: 12.96 [6.40-19.53], P = .0001; NMA: 8.89 [3.27-14.51], P < .01). The procedural duration was also shorter for the cryoballoon with NMA, RF vs CRYO (20.56 [3.47-37.65], P = .02). DISCUSSION: Our analysis demonstrated that while there was no difference in the efficacy of the individual catheter technologies, there are significant differences in the procedural duration for the PVAC and the cryoballoon. While they may seem an attractive solution for high-volume centers, further RCTs of next-generation technologies should be examined.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Humanos , Metaanálisis en Red , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Ensayos Clínicos Controlados Aleatorios como Asunto , Tecnología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA