RESUMEN
BACKGROUND: The increased demand for decentralized blood sample collection presents numerous operational challenges for diagnostics providers. Sample degradation including sample hemolysis due to time, temperature, and handling between collection and laboratory analysis leads to limited test menus and unreliable results. Here we introduce the lightweight, portable Labcorp TrueSpin™ for rapid point-of-care blood separation using commercially available microvolume blood collection tubes. The TrueSpin is a class I FDA-registered device designed for untrained users. The centrifuge runs on AA batteries and separates a blood sample in 5 minutes. METHODS: Here we describe a series of studies evaluating sample quality and analyte stability in serum samples collected into gel microtubes and processed using the TrueSpin. Hemolysis, residual red blood cell concentration, sample volume, and serum-based chemistry analyte stability were evaluated. RESULTS: No significant difference was seen in hemolysis or residual red blood cell concentration in serum samples prepared by TrueSpin compared to the reference method. Additionally, capillary and venous blood samples separated using the TrueSpin and exposed to International Safe Transit Association 3A-simulated shipping conditions were shown to yield acceptable sample volume and quality for laboratory analysis. Finally, we show that many common serum-based chemistry analytes have limited (< 1 day) stability if uncentrifuged but improve to ≥ 3-day stability following TrueSpin separation and refrigerated or room temperature storage. CONCLUSIONS: These findings suggest that the TrueSpin is a simple and effective solution for remote sample separation and may enable broader test menus and increased test result reliability for decentralized sample collection pursuits.
Asunto(s)
Recolección de Muestras de Sangre , Hemólisis , Humanos , Reproducibilidad de los Resultados , Recolección de Muestras de Sangre/métodos , Manejo de Especímenes , Factores de TiempoRESUMEN
Blood sample collection and rapid separation-critical preanalytical steps in clinical chemistry-can be challenging in decentralized collection settings. To address this gap, the Torq™ zero delay centrifuge system includes a lightweight, hand-portable centrifuge (ZDrive™) and a disc-shaped blood collection device (ZDisc™) enabling immediate sample centrifugation at the point of collection. Here, we report results from clinical validation studies comparing performance of the Torq System with a conventional plasma separation tube (PST). Blood specimens from 134 subjects were collected and processed across three independent sites to compare ZDisc and PST performance in the assessment of 14 analytes (K, Na, Cl, Ca, BUN, creatinine, AST, ALT, ALP, total bilirubin, albumin, total protein, cholesterol, and triglycerides). A 31-subject precision study was performed to evaluate reproducibility of plasma test results from ZDiscs, and plasma quality was assessed by measuring hemolysis and blood cells from 10 subject specimens. The ZDisc successfully collected and processed samples from 134 subjects. ZDisc results agreed with reference PSTs for all 14 analytes with mean % biases well below clinically significant levels. Results were reproducible across different operators and ZDisc production lots, and plasma blood cell counts and hemolysis levels fell well below clinical acceptance thresholds. ZDiscs produce plasma samples equivalent to reference PSTs. Results support the suitability of the Torq System for remotely collecting and processing blood samples in decentralized settings.