Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 183
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(1): 97-110, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37897084

RESUMEN

INTRODUCTION: The clinical outcomes and mechanisms of delayed responses to cardiac resynchronization therapy (CRT) remain unclear. We aimed to investigate the differences in outcomes and gain insight into the mechanisms of early and delayed responses to CRT. METHODS: This retrospective study included 110 patients who underwent CRT implantation. Positive response to CRT was defined as ≥15% reduction of left ventricular (LV) end-systolic volume on echocardiography at 1 year (early phase) and 3 years (delayed phase) after implantation. The latest mechanical activation site (LMAS) of the LV was identified using two-dimensional speckle-tracking radial strain analysis. RESULTS: Seventy-eight (71%) patients exhibited an early response 1 year after CRT implantation. Of 32 non-responders in the early phase, 12 (38%) demonstrated a delayed response, and 20 (62%) were classified as non-responders after 3 years. During the follow-up time of 10.3 ± 0.5 years, the delayed and early responders had a similar prognosis of mortality and heart failure (HF) hospitalization. In contrast, non-responders had a worse prognosis. Multivariate analysis revealed that a longer duration (months) between initial HF hospitalization and CRT (odds ratio [OR]: 1.126; 95% confidence interval [CI]: 1.036-1.222; p = .005), non-exact concordance of LV lead location with LMAS (OR: 32.744; 95% CI: 1.101-973.518; p = .044), and pre-QRS duration (OR: 0.901; 95% CI: 0.827-0.981; p = .016) were independent predictors of delayed response to CRT compared with early response. CONCLUSION: The prognoses were similar regardless of the response time after CRT. A longer history of HF, suboptimal LV lead position, and shorter pre-QRS duration were related to delayed response than early response.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Ecocardiografía , Pronóstico , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia
2.
Artículo en Inglés | MEDLINE | ID: mdl-38837477

RESUMEN

INTRODUCTION: The underlying risks of asymptomatic embolization during high-power short-duration (HPSD) ablation for atrial fibrillation remain unclear. We aimed to evaluate microembolic signals (MESs) during HPSD ablation with power settings of 50 and 90 W in comparison with those during cryoballoon (CB) ablation using a novel carotid ultrasound-Doppler system that classifies solid and air bubble signals using real-time monitoring. METHODS AND RESULTS: Forty-seven patients underwent HPSD ablation using radiofrequency (RF), and 13 underwent CB ablation. MESs were evaluated using a novel pastable soft ultrasound probe equipped with a carotid ultrasound during pulmonary vein isolation. We compared the detailed MESs and their timing between RF and CB ablations. The number of MESs and solid signals were significantly higher in the RF group than in CB group (209 ± 229 vs. 79 ± 32, p = .047, and 83 ± 89 vs. 28 ± 17, p = .032, respectively). In RF ablation, the number of MESs, solid, and bubble signals per ablation point, or per second, was significantly higher at 90 W than at 50 W ablation. The MESs, solid, and bubble signals were detected more frequently in the bottom and anterior walls of the left pulmonary vein (LPV) ablation. In contrast, many MESs were observed before the first CB application and decreased chronologically as the procedure progressed. Signals were more prevalent during the CB interval rather than during the freezing time. Among the 28 patients, 4 exhibited a high-intensity area on postbrain magnetic resonance imaging (MRI). The MRI-positive group showed a trend of larger signal sizes than did the MRI-negative group. CONCLUSION: The number of MESs was higher in the HPSD RF group than in the CB group, with this risk being more pronounced in the 90 W ablation group. The primary detection site was the anterior wall of the LPV in RF and the first interval in CB ablation.

3.
J Cardiovasc Electrophysiol ; 35(4): 821-831, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38424678

RESUMEN

INTRODUCTION: Intrinsic antitachycardia pacing (iATP) is a novel automated antitachycardia pacing (ATP) that provides individual treatment to terminate ventricular tachycardia (VT). However, the clinical efficacy of iATP in comparison with conventional ATP is unknown. We aim to compare the termination rate of VT between iATP and conventional ATP in patients with implantable cardioverter-defibrillators using a unique setting of different sequential orders of both ATP algorisms. METHODS: Patients with the iATP algorithm were assigned to iATP-first and conventional ATP-first groups sequentially. In the iATP-first group, a maximum of seven iATP sequences were delivered, followed by conventional burst and ramp pacing. In contrast, in the conventional ATP-first group, two bursts and ramp pacing were initially programmed, followed by iATP sequences. We compared the success rates of VT termination in the first and secondary programmed ATP zones between the two groups. RESULTS: Fifty-eight and 56 patients were enrolled in the iATP-first and conventional ATP-first groups, and 67 and 44 VTs were analyzed in each group, respectively. At the first single ATP therapy, success rates were 64% and 70% in the iATP and conventional groups, respectively. At the end of the first iATP treatment zone, the success rate increased from 64% to 85%. Moreover, secondary iATP therapy following the failure of conventional ATPs increased the success rate from 80% to 93%. There was a significant benefit of alternative iATP for VT termination compared to secondary conventional ATP (100% vs. 33%, p = .028). CONCLUSIONS: iATP may be beneficial as a secondary therapy after failure of conventional ATP to terminate VT.


Asunto(s)
Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Resultado del Tratamiento , Estimulación Cardíaca Artificial/efectos adversos , Adenosina Trifosfato
4.
J Cardiovasc Electrophysiol ; 34(3): 627-637, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36651347

RESUMEN

INTRODUCTION: Diagnosis of outflow tract ventricular arrhythmia (OTVA) localization by an electrocardiographic complex is key to successful catheter ablation for OTVA. However, diagnosing the origin of OTVA with a precordial transition in lead V3 (V3TZ) is challenging. This study aimed to create the best practical electrocardiogram algorithm to differentiate the left ventricular outflow tract (LVOT) from the right ventricular outflow tract (RVOT) of OTVA origin with V3TZ using machine learning. METHODS: Of 498 consecutive patients undergoing catheter ablation for OTVA, we included 104 patients who underwent ablation for OTVA with V3TZ and identified the origin of LVOT (n = 62) and RVOT (n = 42) from the results. We analyzed the standard 12-lead electrocardiogram preoperatively and measured 128 elements in each case. The study population was randomly divided into training group (70%) and testing group (30%), and decision tree analysis was performed using the measured elements as features. The performance of the algorithm created in the training group was verified in the testing group. RESULTS: Four measurements were identified as important features: the aVF/II R-wave ratio, the V2S/V3R index, the QRS amplitude in lead V3, and the R-wave deflection slope in lead V3. Among them, the aVF/II R-wave ratio and the V2S/V3R index had a particularly strong influence on the algorithm. The performance of this algorithm was extremely high, with an accuracy of 94.4%, precision of 91.5%, recall of 100%, and an F1-score of 0.96. CONCLUSIONS: The novel algorithm created using machine learning is useful in diagnosing the origin of OTVA with V3TZ.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Algoritmos , Arritmias Cardíacas , Electrocardiografía/métodos , Ventrículos Cardíacos , Aprendizaje Automático
5.
Pacing Clin Electrophysiol ; 46(4): 341-345, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36914408

RESUMEN

Deep septal ventricular pacing is a recently developed physiological pacing modality with good efficacy; however, it has a potential risk of unusual complications. Here, we report a patient with pacing failure and spontaneous, complete lead dislodgement after >2 years of deep septal pacing, possibly caused by systemic bacterial infection and specific lead behavior in the septal myocardium. This case report may implicate a hidden risk of unusual complications in deep septal pacing.


Asunto(s)
Estimulación Cardíaca Artificial , Ventrículos Cardíacos , Humanos , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos
6.
J Cardiovasc Electrophysiol ; 33(7): 1515-1528, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35598302

RESUMEN

INTRODUCTION: Reactive atrial-based antitachycardia pacing (rATP) in patients with cardiac implantable electronic devices (CIEDs) suppresses the progression of atrial fibrillation (AF) to the persistent form. However, the clinical factors associated with successful reactive atrial-based antitachycardia pacing (rATP) treatment are unknown. This study aimed to examine the predictors of high rATP efficacy in patients with CIEDs. METHODS: The data of 101,325 rATP-treated atrial tachyarrhythmia (AT/AF) episodes in 51 patients, obtained through remote monitoring and device interrogation, were analyzed. The study population was divided into the high and low efficacy groups based on the overall median success rate of rATP. Clinical characteristics were compared between the two groups. RESULTS: During a follow-up period of 28.6 ± 8.6 months, the median success rate was 43.7% (31.5%-64.9%). The prevalence of a history of catheter ablation of AF was significantly higher in the high efficacy group than in the low efficacy group (73.0% vs. 44.0%, p = .048) and was the only independent predictor of high rATP efficacy (odds ratio, 3.45; p = .038). The rATP success rate in patients with (n = 30) and without (n = 21) a history of catheter ablation was 53.9% (40.0%-67.5%) and 36.4% (22.2%-47.7%), respectively (p = .012). The effect of rATP after ablation was more pronounced in patients with long cycle length episodes (≥75% of AT/AF sequences having a cycle length of 200-449 ms) (67.3% [46.0%-73.6%] vs. 30.6% [18.1%-60.3%], p = .027). The high efficacy group had a significantly lower incidence of AT/AF lasting ≥1, ≥7, and ≥30 days than the low efficacy group. CONCLUSION: rATP combined with catheter ablation therapy is effective in suppressing AT/AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Electrónica , Atrios Cardíacos/cirugía , Humanos , Resultado del Tratamiento
7.
J Cardiovasc Electrophysiol ; 33(12): 2447-2464, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36168875

RESUMEN

INTRODUCTION: Data are limited regarding outcomes of cryoballoon ablation for atrial fibrillation (AF) in patients with heart failure (HF). This large-scale multicenter study aimed to evaluate the prognosis of patients with HF after cryoballoon ablation for AF. METHODS: Among 3655 patients undergoing cryoballoon ablation at 17 institutions, 549 patients (15%) (391 with paroxysmal AF and 158 with persistent AF) diagnosed with HF preoperatively were analyzed. Clinical endpoints were recurrence, mortality, and HF hospitalization after ablation. RESULTS: Most patients had a preserved left ventricular ejection fraction (LVEF) ≥ 50%. During a mean follow-up period of 25.7 months, recurrence, all-cause death, and HF hospitalization occurred in 29%, 4.0%, and 4.8%, respectively. Cardiac function on echocardiography and B-type natriuretic peptide (BNP) levels significantly improved postoperatively, and the effect was more pronounced in the nonrecurrence group. Major complications occurred in 33 patients (6.0%), but most complications were phrenic nerve palsy (3.6%). Although death and HF hospitalization occurred more frequently in patients with LVEF ≤ 40% (n = 73) and New York Heart Association (NYHA) class III-IV (n = 19) than other subgroups, the BNP levels, and LVEF significantly improved after ablation in all LVEF and NYHA class subgroups. High BNP levels, NHYA class, CHADS2 score, and structural heart disease, but not postablation recurrence, independently predicted death, and HF hospitalization on multivariate analysis. The patients with tachycardia-induced cardiomyopathy had better recovery of BNP levels and LVEF after ablation than those with structural heart disease. CONCLUSIONS: Cryoballoon ablation for AF in HF patients is feasible and leads to significantly improved cardiac function.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Cardiopatías , Insuficiencia Cardíaca , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Volumen Sistólico , Función Ventricular Izquierda , Estudios de Factibilidad , Resultado del Tratamiento , Cardiopatías/cirugía
8.
Circ J ; 87(1): 65-73, 2022 12 23.
Artículo en Inglés | MEDLINE | ID: mdl-36130909

RESUMEN

BACKGROUND: Radiofrequency hotballoon (RHB) is an ablation device used for atrial fibrillation (AF) treatment. The efficacy and safety of RHB-based pulmonary vein isolation (PVI) in real-world practice are unknown.Methods and Results: A multicenter, prospective registry study (UMIN000029567) enrolled AF patients who underwent RHB-PVI. The primary endpoint was the AF recurrence-free survival rate at 12 months after PVI. Of the 679 patients enrolled, 613 (90.3%; paroxysmal AF, n=370; persistent AF, n=136; long-standing AF, n=107) underwent initial RHB-PVI. Acute isolation using only the RHB was successful for 55.6% of patients and 83.5% of pulmonary veins (PVs). The acute isolation rate was higher for patients with paroxysmal AF and more experienced centers. Antiarrhythmic drugs were prescribed after 3 months for 47.5% of patients. The AF recurrence-free survival rate at 12 months was 83.7%. Procedure-related complications including atrio-esophageal fistula (n=1) and phrenic nerve injury (persistent; n=4, permanent; n=2) were observed in 19 (3.1%) patients. Five (1.7%) of the 302 patients who underwent pre-procedural and post-procedural multidetector computed tomography had severe PV stenosis. CONCLUSIONS: The size-adjustable RHB has been used for the treatment of various AF types. The arrhythmia recurrence-free rate at 12 months, with the use of antiarrhythmic drugs in approximately half of the patients, was acceptable, but the acute isolation rate using the RHB requires further improvement.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Antiarrítmicos/uso terapéutico , Estudios Prospectivos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
9.
Circ J ; 86(2): 268-276, 2022 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-34373432

RESUMEN

BACKGROUND: The relationship between nutritional status and the incidence or prognosis of atrial fibrillation (AF) has been reported, but no studies have described the relationship between the outcomes of AF catheter ablation (CA) and nutritional status as assessed by various scoring tools. We aimed to verify the hypothesis that preoperative nutritional status is associated with arrhythmia recurrence after CA for AF.Methods and Results:We evaluated 913 patients (age, 67±10 years; men, 72%; paroxysmal AF, 56%) who underwent CA for AF between November 2011 and November 2017. Patients were systematically followed with an endpoint of atrial tachyarrhythmia recurrence, the predictive value of which was compared among 3 scoring tools (Controlling Nutritional Status [CONUT] score / Geriatric Nutritional Risk Index [GNRI] / Prognostic Nutritional Index [PNI]). Patients were divided into normal nutrition (CONUT <2 [n=637] / GNRI >98 [n=836] / PNI >38 [n=910]) and undernutrition (CONUT ≥2 [n=276] / GNRI ≤98 [n=77] / PNI ≤3 [n=3]) groups. AF recurred in 274 patients (mean follow-up, 2.3±0.8 years). The AF recurrence rate was higher in patients with undernutrition than in those with normal nutrition (CONUT/GNRI) status. Multivariate Cox regression analysis identified undernutrition status (GNRI ≤98) as an independent predictor of atrial tachyarrhythmia recurrence. CONCLUSIONS: The AF recurrence rate after CA was higher in patients with undernutrition than in those with normal nutrition as stratified by the nutrition scoring tools.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Desnutrición , Anciano , Humanos , Masculino , Desnutrición/complicaciones , Persona de Mediana Edad , Estado Nutricional , Pronóstico , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
10.
BMC Cardiovasc Disord ; 22(1): 457, 2022 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-36319975

RESUMEN

BACKGROUND: Left atrial (LA) conduction velocity (CV) is an electrical remodeling parameter of atrial fibrillation (AF) substrate. However, the pathophysiological substrate of LA-CV and its impact on outcomes after catheter ablation for AF have not been well evaluated. METHODS: We retrospectively evaluated 119 patients with AF who underwent catheter ablation and electroanatomical mapping during sinus rhythm. To measure regional LA-CV, we took triplet sites (A, B, and C) on the activation map and calculated the magnitude of the matched orthogonal projection vector between vector-AB and vector-AC, indicating two-dimensional CV. The median of the LA-CVs from four triad sites in both the anterior and posterior walls was set as the 'model LA-CV'. We evaluated the impact of the model LA-CV on recurrence after ablation and relationship between the model LA-CV and LA-low voltage area (LVA) of < 0.5 mV. RESULTS: During the 12-month follow-up, 29 patients experienced recurrence. The LA-CV model was significantly correlated with ipsilateral LVA. The lower anterior model LA-CV was significantly associated with recurrence, with the cut-off value of 0.80 m/s having a sensitivity of 72% and specificity of 67%. Multivariable analysis revealed that the anterior model LA-CV (hazard ratio, 0.09; 95% confidence interval, 0.01-0.94; p = 0.043) and anterior LA-LVA (hazard ratio, 1.06; 95% confidence interval, 1.00-1.11; p = 0.033) were independently associated with AF recurrence. The anterior LA-LVA was mildly correlated with the anterior model LA-CV (r = -0.358; p < 0.001), and patients with both lower LA-CV and greater anterior LA-LVA based on each cut-off value had the worst prognosis. However, decreased LA-CV was more likely to be affected by the distribution pattern of the LVA rather than the total size of the LVA. CONCLUSION: Decreased anterior LA-CV was a significant predictor of AF recurrence and was a useful electrical parameter in addition to LA-LVA for estimating AF arrhythmogenicity.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Técnicas Electrofisiológicas Cardíacas/métodos , Estudios Retrospectivos , Ablación por Catéter/métodos , Atrios Cardíacos , Recurrencia , Resultado del Tratamiento
11.
BMC Cardiovasc Disord ; 22(1): 13, 2022 01 22.
Artículo en Inglés | MEDLINE | ID: mdl-35065605

RESUMEN

BACKGROUND: The efficacy of pulmonary vein isolation (PVI) alone is not guaranteed for persistent atrial fibrillation (PeAF), and it is unclear which type of ablation approach should be applied in addition to PVI. This study aimed to compare outcomes and prognosis between empirical linear ablation and low-voltage area (LVA) ablation after PVI for PeAF. METHODS: We enrolled 128 patients with PeAF who were assigned to the linear ablation group (n = 64) and the LVA ablation group (n = 64) using a propensity score-matched model. After PVI and cardioversion, the patients underwent either empirical linear ablation or LVA ablation during sinus rhythm. All patients in the linear ablation group underwent both roof line and mitral valve isthmus (MVI) ablations. An electrical-guided ablation targeting LVA (< 0.5 mV) was performed in the LVA group. When there was no LVA in the LVA group, only PVI was applied. We compared the procedural outcomes and recurrence after ablation between the two groups. RESULTS: The baseline characteristics were well-balanced between the two groups. Fifty patients had LVA (22 and 28 patients in the linear and LVA groups). The roof and MVI lines were completed in 100% and 96.9% of the patients. During the mean follow-up of 279.5 ± 161.3 days, the LVA group had significantly lower recurrence than the linear group (15 patients [23%] vs. 29 patients [45%], p = 0.014). Thirty-five patients were prescribed antiarrhythmic drugs during the follow-up period (linear group, n = 17; LVA group, n = 18); amiodarone and bepridil were administered to most of the patients (15 and 17 patients, respectively). The difference in the prognosis was relevant among the patients with LVA, while this trend was not observed in those without LVA. The LVA ablation group demonstrated significantly lower radiofrequency energy and shorter procedural time compared to the linear ablation group. The recurrence of atrial flutter was more likely to occur in the linear group than in the LVA group (14 [22%] vs. 6 [9.4%], p = 0.052). CONCLUSION: The electrophysiological-guided LVA ablation is more effective than empirical linear ablation in PeAF patients with LVA. Unnecessary empirical linear ablation might have a risk of iatrogenic gap and atrial flutter recurrence.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Frecuencia Cardíaca/fisiología , Puntaje de Propensión , Venas Pulmonares/cirugía , Cirugía Asistida por Computador/métodos , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Imagenología Tridimensional , Masculino , Pronóstico , Estudios Retrospectivos , Factores de Tiempo
12.
Pacing Clin Electrophysiol ; 45(11): 1299-1302, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35675325

RESUMEN

Septal coronary artery fistula is a rare but concerning complication of left bundle branch area pacing (LBBAP). We report the case of an 82-year-old man who was indicated for cardiac resynchronization therapy and underwent LBBAP. The patient had no chest symptoms during or after implantation. Postoperative echocardiography demonstrated a new abnormal tunnel inside the interventricular septum (IVS) and shunt flow from the IVS toward the right ventricle. Coronary angiography confirmed a septal coronary artery fistula, which might have been formed by failed deep screw attempts. Since the shunt volume assessed by the Qp /Qs was small, the patient was treated conservatively.


Asunto(s)
Terapia de Resincronización Cardíaca , Fístula , Masculino , Humanos , Anciano de 80 o más Años , Fascículo Atrioventricular , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Bloqueo de Rama/diagnóstico , Estimulación Cardíaca Artificial/métodos , Vasos Coronarios/diagnóstico por imagen , Electrocardiografía/métodos , Terapia de Resincronización Cardíaca/métodos
13.
Heart Vessels ; 37(5): 775-787, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34705091

RESUMEN

Atrial ectopy (AE) with a short coupling interval (S-AE) causes atrial fibrillation (AF). A higher burden of AE is associated with recurrence after AF ablation. However, a few reports have evaluated the prognostic impact of both AE burden and S-AE after the acute phase of ablation. This study aimed to assess the characteristics of AE beyond the blanking period in predicting the recurrence. We retrospectively analyzed 173 patients who underwent first catheter ablation for AF and 24-h Holter recording following a 3-month blanking period. AE was defined as a narrow QRS complex occurring < 75% earlier than the prior reference R-R interval. We investigated the relationship between the AE's characteristics in Holter recordings and atrial arrhythmia recurrence. Forty-two patients (24%) had a recurrence during a median 488-day follow-up. Patients with S-AE (minimum coupling interval ratio of AE ≤ 45%) had a higher recurrence rate than those without S-AE (44.9% vs. 16.1%, p < 0.001). Moreover, patients with AE ≥ 241/day exhibited a significantly higher recurrence rate than those with AE < 241/day (44.3% vs. 10.7%, p < 0.001). In multivariate analysis, S-AE with a higher AE burden was an independent predictor of recurrence (hazard ratio 5.82, 95% confidence interval: 2.64-12.82, p < 0.001). Kaplan-Meier analysis showed that patients with S-AE and a higher AE burden had the worst prognosis for recurrence (p < 0.001). The combination of a higher AE burden with S-AE could be an efficient predictor of recurrence. These results can help to develop follow-up strategies after AF ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Modelos de Riesgos Proporcionales , Venas Pulmonares/cirugía , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
14.
Heart Vessels ; 37(3): 476-488, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34432100

RESUMEN

P-wave morphology reflects atrial remodeling and indicates prognosis after radiofrequency catheter ablation (RFCA) for atrial fibrillation (AF). The impact of p-wave morphology after excluding the effect of pulmonary vein (PV) substrate on outcomes is unknown. We evaluated the p-wave morphology on electrocardiography immediately after PV isolation for clinical outcomes. Eighty-four consecutive patients (47 with paroxysmal AF and 37 with persistent AF) who underwent RFCA were included. P-wave duration (PWD) and amplitude in all leads were examined during sinus rhythm immediately after PV isolation. We evaluated the relationship between electrocardiogram parameters and AF recurrence, according to the type of AF and following ablation, and the correlation with left atrial (LA) volume, low voltage ratio, and fixed conduction time. During 12 months of follow-up, 20 patients experienced recurrence. The cut-off value of PWD > 120 ms in lead I showed a sensitivity of 75% and specificity of 69% for predicting recurrence. PWD was significantly correlated with LA volume, low voltage, and conduction velocity. Significantly higher recurrence rates were observed in patients with PWD > 120 ms than in those with PWD ≤ 120 ms (p < 0.001), and the difference was more pronounced in patients with persistent AF. Multivariate analysis demonstrated that PWD > 120 ms was independently associated with recurrence in the total population (hazard ratio 2.00; 95% confidence interval 1.27-3.22; p = 0.003) and in patients with persistent AF. In conclusion, long PWD after PV isolation predicts AF recurrence, which might be associated with the extent of the LA substrate in persistent AF.


Asunto(s)
Fibrilación Atrial , Remodelación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Electrocardiografía , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
15.
Heart Vessels ; 37(5): 840-853, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34708268

RESUMEN

Focal activation is believed to be an atrial fibrillation (AF) driver; however, little is known about whether all focal activations are necessary for AF persistence. The purpose of this study was to assess the electrical nature of focal activation and identify high-priority focal activations using a novel mapping system (CARTOFINDER). Thirty-five patients with persistent AF who underwent catheter ablation were assessed. Cycle length (CL) and CL standard deviation (CLSD) on unipolar recordings and voltage amplitude and electrogram morphologies on bipolar recordings were evaluated at all points of interest. The most frequent CL at each mapping site was defined as the dominant CL. We identified dominant focal activations (DFAs) that had a shorter dominant CL on the integrated CARTOFINDER map. The effect of elimination of DFAs on AF maintenance was assessed by the composite endpoint (termination to sinus rhythm, organization of the rhythm to atrial tachycardia, and AF CL slowing). In all, 450 focal activations were identified among 10,868 points, and 50.4% of focal activations were DFAs. Focal activations showed relatively long CL and regularity with short CLSD. Most focal activations showed an isoelectric baseline and were located outside of the fractionated electrogram area. Both DFAs and non-DFAs were typically observed in the normal voltage range. Elimination of DFAs was achieved in 19 (54.3%) patients, with a remarkable impact on AF maintenance (68.4% vs. 25.0%, p = 0.018). In conclusion, DFAs may play an important role in AF maintenance and could be an attractive therapeutic target for AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Taquicardia Supraventricular , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas , Humanos , Taquicardia Supraventricular/cirugía , Resultado del Tratamiento
16.
Heart Vessels ; 37(5): 765-774, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34636968

RESUMEN

In cryoballoon ablation (CBA), a contrast medium is commonly used to confirm balloon occlusion of the pulmonary veins (PVs). However, a contrast medium cannot always be used in patients with renal dysfunction and allergy. The present study aimed to assess the efficacy and safety of CBA without the use of a contrast medium. We retrospectively examined consecutive patients with paroxysmal atrial fibrillation (PAF) who underwent first-time CBA. We compared the procedural results and outcomes in patients for whom a contrast medium was used (contrast group) and those from whom a contrast medium was not used (non-contrast group). In the non-contrast group, we used saline injection on the intracardiac echocardiography and pressure wave monitoring for PV occlusion. Fifty patients (200 PVs) and 22 patients (88 PVs) underwent CBA with and without a contrast medium, respectively. The success rate of PV isolation with CBA alone was 93% and 90% in the non-contrast and contrast groups, respectively (p = 0.40). The fluoroscopy time and nadir temperature were significantly lower in the non-contrast group as compared to that in the contrast group. The recurrence rate 1 year after ablation did not differ between the two groups (18% vs. 18%, p > 0.99). Furthermore, the number of reconnected PVs in patients with recurrence was significantly lower in the non-contrast group than in the contrast group (6% vs. 36%, p = 0.017). In conclusion, CBA using the intracardiac echocardiography and pressure monitoring approach without the use of a contrast medium was safe and efficient.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Criocirugía/métodos , Ecocardiografía/métodos , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
17.
Ann Noninvasive Electrocardiol ; 27(5): e12991, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35802829

RESUMEN

BACKGROUND: The current study aimed to evaluate changes in electrical depolarization and repolarization parameters after His-bundle pacing (HBP) compared with right ventricular pacing (RVP) and its association with ventricular arrhythmia (VA). METHODS: Forty-one patients (13 with HBP, 14 with RVP, and 14 controls [AAI mode]) were evaluated. After continuous pacing algorithm, QRS duration, QT interval, QTc, JT interval, T-peak to T-end (Tpe), and Tpe/QT ratio were measured on electrocardiography at baseline and 1 week, 1 month, and 6 months postoperatively. We investigated VA occurrence and adverse events after implantation. RESULTS: At 6 months, QRS duration was significantly shorter in the HBP (121.6 ± 15.6 ms) than in the RVP (150.1 ± 14.9 ms) group. The QT intervals were lower in the HBP (424.0 ± 40.9 ms) and control (405.9 ± 23.0 ms) groups than in the RVP (453.0 ± 40.2 ms) group. The Tpe and Tpe/QT ratios at 6 months differed significantly between the HBP and RVP groups (Tpe, 69.8 ± 19.7 ms vs 87.4 ± 11.9 ms and Tpe/QT, 0.16 ± 0.03 vs 0.19 ± 0.02, respectively). The Tpe and Tpe/QT ratios were similarly shortened in the HBP and control groups. VA occurred less frequently in the HBP (15%) and control (7.1%) groups than in the RVP (50%) group (p = 0.020). The non-RVP group showed significantly lower rates of VA and major adverse events than the RVP group. Patients with VA demonstrated significantly longer QRS duration, QT interval, Tpe, and Tpe/QT at 6 months than those without VA. CONCLUSION: HBP showed better depolarization and repolarization stability than RVP.


Asunto(s)
Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Arritmias Cardíacas , Electrocardiografía , Frecuencia Cardíaca , Ventrículos Cardíacos , Humanos , Resultado del Tratamiento
18.
Int Heart J ; 63(3): 633-638, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35650163

RESUMEN

We report the usefulness of novel automated anti-tachycardia pacing (ATP) for ventricular tachycardia (VT) termination evaluated in an electrophysiology study. This intrinsic, automated ATP with an implanted cardiac resynchronization therapy-defibrillator successfully terminated the sustained VT, which had not been suppressed by repetitive burst pacing from the electrode catheter. The reproduction of programed pacing of the automated ATP by a right ventricular electrode catheter was effective in terminating VT, and this termination was absolute and reproducible. Further detailed assessment in an electrophysiology study could highlight the algorithm of the automated ATP and its possible benefit in terminating the reentrant VT.


Asunto(s)
Terapia de Resincronización Cardíaca , Taquicardia Ventricular , Adenosina Trifosfato , Algoritmos , Muerte , Electrofisiología , Humanos , Taquicardia Ventricular/terapia
19.
Int Heart J ; 63(1): 159-162, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35095065

RESUMEN

We report here the case of a 92-year-old woman with atrial fibrillation bradycardia in which leadless pacemaker implantation was performed with a difficult delivery of the catheter sheath due to an extremely large right atrium. Using a snare technique with correction of the direction of the force on the catheter toward the right ventricle (RV) can result in successful delivery of the pacemaker catheter and stable placement of the pacemaker system in the RV septum. This specific snare technique has the potential to facilitate leadless pacemaker implantation safely in a severely dilated chamber of the heart, making this technique effective to use in clinical practice.


Asunto(s)
Fibrilación Atrial/terapia , Bradicardia/terapia , Cateterismo Cardíaco/métodos , Marcapaso Artificial , Implantación de Prótesis/métodos , Anciano de 80 o más Años , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Bradicardia/complicaciones , Bradicardia/diagnóstico , Femenino , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/patología , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/patología , Humanos
20.
J Cardiovasc Electrophysiol ; 32(11): 2933-2942, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34535938

RESUMEN

INTRODUCTION: With regard to short-term outcome in atrial fibrillation (AF), the benefit of cryoballoon ablation (CBA) by pressing a balloon against the earliest pulmonary vein (PV) potential site during PV isolation (earliest potential [EP]-guided CBA) has been previously demonstrated. The present study aimed to evaluate the long-term outcome of the EP-guided CBA. METHODS AND RESULTS: This study included 136 patients from two randomized studies, who underwent CBA for paroxysmal AF for the first time. Patients were randomly assigned to the EP-guided and conventional CBA groups in each study. In the EP-guided CBA group, we pressed a balloon against the EP site when the time-to-isolation (TTI) after cryoapplication exceeded 60 and 45 s in the first and second studies, respectively. We compared the clinical outcomes for 1 year after the procedure between the EP-guided CBA group (68 patients) and the conventional CBA group (68 patients). The primary endpoint was the recurrence of atrial arrhythmia after ablation. No significant differences in baseline characteristics were observed between the two groups. Compared with the conventional CBA group, the EP-guided CBA group had a significantly higher success rate at TTI ≤ 90 s (98.5% vs. 90.0%, p < .001); lower touch-up rate and total cryoapplication; and shorter procedure time, and fluoroscopy time. The recurrence at 1 year after ablation was significantly lower in the EP-guided CBA group than in the conventional CBA group (6.0% vs. 19.4%; p = .019). CONCLUSIONS: The EP-guided CBA approach can facilitate the ablation procedure and achieve low recurrence at 1 year after ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Ensayos Clínicos Controlados Aleatorios como Asunto , Recurrencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS