1.
Pediatr Surg Int ; 39(1): 269, 2023 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-37679509

RESUMEN

PURPOSE: Since pediatric stomas are often temporary, their creation, management, and closure should be simple, with minimal complications and excellent cosmetic results. We began employing umbilical stomas in 2000. This study aimed to characterize the ingenuity and utility of umbilical stomas and provide a quantitative evaluation of their cosmetic outcomes. METHODS: We examined cases of stoma construction and closure surgery performed in our department from January 2000 to December 2022. The umbilical and non-umbilical stoma groups included 54 and 42 cases, respectively, and the findings for both groups were compared and analyzed. RESULTS: The two groups showed no significant differences in the incidence of complications. The Manchester Scar Scale score for the umbilical stoma group (8.42 ± 1.85) was significantly better than that for the non-umbilical stoma group (16.31 ± 2.96; P < 0.01). Likewise, in Patient and Observer Scar Assessment Scale assessments, the umbilical stoma group showed significantly better scores in both the observer scale (9.48 ± 2.50 vs. 21.78 ± 7.26; P < 0.01) and the patient scale (10.5 ± 1.39 vs. 22.40 ± 7.35; P < 0.01). CONCLUSIONS: Umbilical stomas are easy to manage and yield an inconspicuous closure incision with excellent cosmetic outcomes. Although patient selection is important, pediatric umbilical stomas are a valuable option that can be actively employed.


Asunto(s)
Cicatriz , Estomas Quirúrgicos , Humanos , Niño , Selección de Paciente
2.
Int Orthop ; 47(1): 187-192, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36416898

RESUMEN

PURPOSE: Acoustic analysis has recently been applied to cementless total hip arthroplasty (THA). The aim of this study was to develop a machine learning algorithm to predict post-operative subsidence with high accuracy. METHODS: The acoustic parameters of the hammering sounds during a broaching procedure for 62 hips in 55 patients who underwent THAs with cementless taper-wedged stem were analysed. The patient's basic background such as age, sex, height, weight and body mass index, the femoral morphological parameters and the hammering sound characteristics of 24 features of normalised sound pressure (nSP) in 24 frequency ranges were applied to binary classification using a support vector machine using the following models with different features: model A, nSP only; model B, nSP + patients' basic background features; model C, nSP + patients' basic background features + femoral morphological parameters. RESULTS: In 62 hips with 310 hammering sounds, 12 hips (19.4%) showed ≥ 3 mm of post-operative subsidence; hence, 60 hammering sounds were set as positive examples and 250 hammering sounds were set as negative examples. The AUC was very high in all models. The accuracy (AUC/sensitivity/specificity/positive predictive value/negative predictive value/accuracy rate) of each model was as follows: model A, 0.963/0.656/0.996/0.980/0.925/0.934; model B, 0.9866/0.675/1.000/1.000/0.928/0.937 and model C, 0.998/0.750/1.000/1.000/0.950/0.957. CONCLUSION: In this study, we developed a high-accuracy machine learning algorithm for post-operative subsidence using acoustic parameters and additional pre-operative features. Our results represent a step toward the realisation of acoustic monitoring to avoid the complication in cementless THA.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera/efectos adversos , Máquina de Vectores de Soporte , Fémur/cirugía , Acústica , Diseño de Prótesis , Estudios Retrospectivos
3.
Int Orthop ; 46(10): 2205-2212, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35840813

RESUMEN

BACKGROUND: Corrosion of stem-cobalt/chromium (Co/Cr) head interface and subsequent systemic Co ion complication have been a clinical concern after total hip arthroplasty (THA). The aim of this study is to investigate correlation between type of femoral head and blood Co ion level. METHODS: One hundred four patients with THA using accolade TMZF and Co/Cr femoral head (32-mm; 55 cases, 36-mm; 20 cases, dual mobility system (DM) with 22.2 or 28-mm inner head; 29 cases) participated in this study, and blood Co ion concentration test was performed in patients a minimum of four years after THA. RESULTS: DM group was significantly older than 32-mm and 36-mm group (DM: 73.9 ± 4.6, 32-mm: 63.3 ± 8.5, 36-mm: 66.8 ± 10.5). The median (interquartile range) blood Co concentration of each group was 32-mm group 0.26 µg/L (0.69), 36-mm group; 0.21 µg/L (0.30); and DM group 0.21 µg/L (0.13). There was a significant difference of Co concentration between DM and 32-mm group (p = 0.023). Abnormal values of the blood Co concentration (> 1 µg/L) were observed in the 32-mm group; 12 cases (21.8%), 36-mm group; 2 cases (10.0%); and DM group; 0 case (0%) (p = 0.018). CONCLUSIONS: Co blood concentration differed among the different sizes of Co/Cr femoral head. THA using DM is a safe option with low risk of complication from cobalt ion if it is used for elderly patients.


Asunto(s)
Cobalto , Prótesis de Cadera , Anciano , Cromo/efectos adversos , Cobalto/efectos adversos , Cabeza Femoral/cirugía , Prótesis de Cadera/efectos adversos , Humanos , Diseño de Prótesis
4.
Int Orthop ; 46(4): 741-748, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34977970

RESUMEN

PURPOSE: Avoiding stem subsidence is crucial for achieving better outcome for cementless total hip arthroplasty (THA). The aim of this study was to develop a prediction model for the incidence of post-operative stem subsidence using full quantitative acoustic parameters in hammering sound during the broaching procedure and to assess the accuracy of this prediction model. METHODS: The acoustic parameters of the hammering sounds during a broaching procedure for 55 hips in 49 patients who underwent THAs with cementless taper-wedged stem were analysed. The stem subsidence was assessed at one month post-operatively, and the relationship between the acoustic parameters and the value of stem subsidence was investigated. RESULTS: The average stem subsidence was 2.15 ± 2.91 mm. The subsidence 3 mm or more was observed in eleven hips (20%), and 5 mm or more was observed in seven hips (12.7%). Basic patient's characteristics, preoperative femoral morphology and immediate post-operative canal fill ratio and stem alignment were not significantly related to the volume of stem subsidence. Nine acoustic parameters were significantly correlated with the value of subsidence. The prediction model for post-operative subsidence using only acoustic parameters during broaching procedure was established, and this model showed a positive prediction value of 100% and a negative prediction value of 90.6% for post-operative stem subsidence at 5 mm or more. CONCLUSION: Post-operative stem subsidence can be predicted by using acoustic parameters of the hammering sound during the broaching procedure. Our results suggest that we are at the start of a new era in which novel and innovative smart technologies can be used to assist in orthopaedic surgery.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Acústica , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Fémur/cirugía , Prótesis de Cadera/efectos adversos , Humanos , Diseño de Prótesis , Estudios Retrospectivos
5.
Int Orthop ; 45(5): 1169-1177, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33619587

RESUMEN

PURPOSE: Cortical hypertrophy (CH) after total hip arthroplasty (THA) is thought as a process of femoral cortical functional adaptation against the stem. However, no study has been performed to investigate the association between CH and femoral head size. The purpose of this study is to investigate the factors related to femoral CH around the cementless stem after THA. METHODS: THAs in 31 patients using 36-mm metal head and as a control, age-matched 62 THAs with 32-mm metal head have been analyzed. Radiographs were reviewed at four years to determine cortical thickness change from immediate post-operative one. Pre-operative and immediate post-operative radiographs were used to calculate the femoral morphology, canal fill ratio, stem alignment, and femoral and acetabular offset. Univariate and multivariate logistic regression analyses were performed to identify the risk factors for CH. RESULTS: Patients with a 36-mm metal head had a significantly higher rate of severe CH (P = 0.001) than those with a 32-mm metal head. The multivariate logistic regression analysis with dependent variables of CH showed that the use of a 36-mm metal head had a significantly positive effect on CH. The odds ratio of a 36-mm metal head in mild CH was 2.517 (95% confidence interval, 1.032-6.143; P = 0.043), and that in severe CH was 8.273 (95% confidence interval, 2.679-25.551; P = 0.000). Age and the canal flare index were weakly and negatively influenced by mild CH. CONCLUSIONS: The use of a 36-mm metal head was the dominant risk factor for CH.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Cabeza Femoral/diagnóstico por imagen , Cabeza Femoral/cirugía , Prótesis de Cadera/efectos adversos , Humanos , Hipertrofia , Polietileno , Diseño de Prótesis , Falla de Prótesis
6.
Int Orthop ; 44(11): 2267-2274, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32623495

RESUMEN

BACKGROUND: Pre-operative evaluation of pelvic motion using the sacral slope (SS) has been proposed for risk assessment of dislocation after total hip arthroplasty (THA). The purposes of this study were to elucidate the statistical characteristics of pre-operative and post-operative pelvic mobility and investigate the relationship between pre-operative spinopelvic factors and post-operative pelvic mobility. METHODS: Eighty-six patients with osteoarthritis were assessed. The parameters evaluated were lumbar lordosis angle and the SS in the standing and sitting preo-peratively and post-operatively. The pelvic mobility was defined as the difference in the SS between standing and sitting. The presence of osteoarthritis in the contralateral hip, spondylolisthesis, vertebral compression fracture and lumbar scoliosis was investigated. RESULTS: The median (interquartile range) pre-operative and post-operative pelvic mobility was 19.0 (13.75-27.0) and 16.0 (10.0-25.25), respectively, with significant difference. The pre-operative SS while standing and pre-operative pelvic mobility were associated with post-operative pelvic mobility (r = 0.409, P < 0.05 and r = 0.533, P < 0.05). The multivariate linear regression analysis showed that the following factors contributed to post-operative pelvic mobility: incidence of osteoarthritis in the contralateral hip, lumbar scoliosis, pre-operative SS while standing and pre-operative SS while sitting. CONCLUSION: The pre-operative and post-operative pelvic mobility is not equal and ranges widely among patients. In addition to assessment of pre-operative pelvic mobility, other pre-operative spinopelvic factors may also influence post-operative pelvic mobility, such as the SS while standing and sitting, the condition of the contralateral hip and the presence of scoliosis. Risk assessment for dislocation using these pre-operative factors may be useful before THA.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas por Compresión , Fracturas de la Columna Vertebral , Artroplastia de Reemplazo de Cadera/efectos adversos , Humanos , Pelvis , Sacro
7.
Arch Orthop Trauma Surg ; 140(12): 2085-2089, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32940804

RESUMEN

Recently, catastrophic failure (i.e., dissociation between the metal femoral head and stem due to stem neck deformation) after total hip arthroplasty (THA) has been reported. Early detection of this complication is very important, because it is accompanied by an increased cobalt concentration in the body, which might influence systemic conditions such as heart failure and immune system diseases. However, early detection of stem neck deformation is considered as difficult. In most cases in the literatures, the diagnosis was made at the time of acute dissociation. We report a case of early detection of stem neck deformation with the 'Bowing-head sign' before acute dissociation. The patient is a 71-year old woman complained of a clicking sensation in the right hip during regular follow-up after THA with a 32-mm cobalt/chromium head with polyethylene insert for osteoarthritis performed 7 years previously. The plain radiograph showed that the angle between the metal femoral head and the axis of the stem neck was not perpendicular ('Bowing-head sign'). Dynamic evaluation under fluoroscopy showed movement of the stem neck in the metal femoral head with hip abduction and adduction. Laboratory data showed abnormal serum cobalt (6.3 µg/L, normal < 1 µg/L) and chromium (3.8 µg/L, normal < 5 µg/L) levels. Considering those radiographic findings, deformation of the stem neck due to trunnionosis was diagnosed, and elective revision surgery was performed without any complications. Plain radiographs after THA should be assessed with attention to this complication, 'Bowing-head sign' must not be overlooked.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Articulación de la Cadera/diagnóstico por imagen , Prótesis de Cadera , Falla de Prótesis , Anciano , Cromo/sangre , Aleaciones de Cromo , Cobalto/sangre , Diagnóstico Precoz , Intervención Médica Temprana , Femenino , Cabeza Femoral/cirugía , Humanos , Metales , Osteoartritis de la Cadera/cirugía , Polietileno , Radiografía , Reoperación/métodos
9.
J Arthroplasty ; 31(7): 1524-8, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-26876944

RESUMEN

BACKGROUND: Noncement femoral fixation in total hip arthroplasty (THA) has been gaining popularity. However, owing to the numerous varieties of uncemented stems and differing types of femoral stem morphology, it is unclear whether the clinical outcomes of all uncemented stems are equal. The aim of this study was to investigate the relationships between canal fill ratio and femoral morphology and early radiologic outcomes in Japanese patients who underwent THA with an uncemented proximally hydroxyapatite-coated, tapered-wedge stem. METHODS: We retrospectively reviewed 103 patients who had undergone THA using a single proximally coated tapered-wedge stem. The relationships between canal fill ratio and femoral morphology and early radiologic outcomes after THA with those stem were investigated. RESULTS: Eighty-one hips were analyzed after inclusion and exclusion criteria were applied. Failed osteointegration proximally was observed in 4 hips (4.9%). Canal flare index was significantly greater in hips with failed osteointegration than in those with successful osteointegration (P = .009). Distal hypertrophy was observed in 14 hips (17.3%). Proximal-distal matching ratio was significantly lower in hips with distal hypertrophy than in those without (P = .01). Canal fill ratio at 2 cm above the lesser trochanter was smaller in hips with failed osteointegration and distal hypertrophy than in those without (P = .02). CONCLUSION: Suboptimal radiologic changes were seen with greater distal fill with smaller proximal fill and with a narrow femoral canal. It is important to select the stem that can achieve the original concept of intended primary and secondary fixation areas.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Fémur/diagnóstico por imagen , Fémur/cirugía , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Prótesis de Cadera , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/instrumentación , Pueblo Asiatico , Cementos para Huesos , Cementación , Materiales Biocompatibles Revestidos , Durapatita , Femenino , Fémur/anatomía & histología , Estudios de Seguimiento , Articulación de la Cadera/anatomía & histología , Humanos , Artropatías/cirugía , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
10.
Surg Case Rep ; 10(1): 20, 2024 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-38228981

RESUMEN

BACKGROUND: The study introduces the application of negative pressure wound therapy (NPWT) in pediatric stoma closure, emphasizing the importance of enhancing aesthetics and minimizing surgical site infections (SSI). CASE PRESENTATION: The case series involves four infants undergoing non-umbilical stoma closure with a combination of purse-string closure (PSC) and NPWT, focusing on aesthetic outcomes and infection prevention. NPWT was initiated immediately after surgery, and patients were monitored every 3-4 days. Notably, none of the four infants experienced SSI or other complications. The patients adequately tolerated NPWT, with no significant adverse events. Furthermore, Manchester Scar Scale (MSS) was 9 [7-10], and Patient and Observer Scar Assessment Scale (POSAS) (observer) was 12.5 [12-19], POSAS (patient) was 12.5 [11-16] (all median values [minimum-maximum]), indicating that excellent aesthetic outcomes were achieved. DISCUSSION: We emphasizes the significance of aesthetics in pediatric patients; in addition, our findings demonstrate that four infants who received NPWT combined with PSC achieved superior outcomes that did the most recent four infants who underwent PSC only at our institution. It also addresses the risk of SSI in stoma closure and discusses the pros and potential cons of using NPWT in pediatric cases, underlining the need for further research and the accumulation of additional reports. CONCLUSIONS: This is the inaugural report of prophylactic NPWT for pediatric stoma closure, emphasizing the effectiveness of combining PSC and NPWT for SSI prevention and improved aesthetics. The study calls for additional research and reports on NPWT in pediatric cases to further solidify its benefits in this patient population.

11.
Arthroplast Today ; 21: 101136, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37193539

RESUMEN

Background: Listening to the change in the hammering sound is 1 of the elements used to assess the cementless stem stability. This study aimed to quantitatively investigate the change in the acoustic characteristics between the early and late phases of cementless stem insertion in total hip arthroplasty and to identify which patient characteristics contribute to the change in the hammering sound. Methods: The acoustic parameters of the hammering sounds in the early and late phases of cementless taper-wedged stem insertion for 51 hips in 45 patients who underwent total hip arthroplasty (mean age = 68 years, height = 1.56 m, weight = 55.0 kg) were analyzed. Parameters including patient's basic characteristics, radiographical femoral morphology, and canal fill ratio were assessed as potential contributors to the change in the hammering sound. Results: The low-frequency bands (0.5-1.0 kHz and 1.0-1.5 kHz) showed the largest changes during stem insertion and were therefore considered key bands for the analysis of sound alterations. Multivariate linear regression analysis showed that height (ß = 8.312, P = .013) and proximal canal fill ratio (ß = -3.8568, P = .038) were independently associated with the sound alterations. The decision tree analysis identified height (≥1.66 m or <1.66 m) as the best single discriminator for the sound alteration. Conclusions: Patients with smaller stature showed the least change in the hammering sound during stem insertion. Understanding the acoustic characteristics of hammering sound alteration during cementless stem insertion may aid in the achievement of optimal stem insertion.

12.
Arthroplasty ; 5(1): 13, 2023 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-37020254

RESUMEN

BACKGROUND: Although it is important to consider pelvic alignment and mobility in the standing and sitting positions before THA, it is not known how to preoperatively predict individual postoperative pelvic alignment and mobility. The purpose of this study was to investigate the pelvic alignment and mobility before and after THA, and to develop a predictive formula using preoperative factors to calculate postoperative sagittal alignment and mobility. METHODS: One hundred seventy patients were assessed. The 170 patients were randomly divided into a prediction model analysis group (n = 85) and an external validation group (n = 85). In the prediction model analysis group, preoperative spinopelvic parameters were used to develop the predictive formulas to predict the postoperative sacral slope (SS) in standing and sitting positions and ΔSS. These were applied to the external validation group and assessed. RESULTS: R2 in multiple linear regression models for postoperative SS in standing, SS in sitting and ΔSS were 0.810, 0.672, and 0.423, respectively. The values of predicted and postoperative parameters were very close with no significant difference: SS in standing (33.87 vs. 34.23, P = 0.834), SS in sitting (18.86 vs. 19.51, P = 0.228), and ΔSS (15.38 vs. 14.72, P = 0.619). CONCLUSION: The present study showed that the pelvic alignment and mobility after THA can be predicted using preoperative factors. Although a model with higher accuracy is needed, it is important to use a predictive formula to estimate the postoperative condition before performing THA.

13.
Expert Rev Med Devices ; 20(12): 1079-1086, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37942898

RESUMEN

INTRODUCTION: The direct anterior approach (DAA) has its origins in the first and oldest approach for hip replacement in the literature, but at the same time it would not be fanciful to suggest its increasing popularity as the latest approach for hip replacement procedures, especially among younger surgeons. However, in a geographical context, the DAA is not considered the major approach in most countries. Moreover, the term DAA encompasses numerous variations in terms of technique. AREAS COVERED: In this narrative review, we describe our recent experience of advances in the DAA in terms of improved techniques and devices, along with some of its disadvantages. Also, we express our perspective on its future application. EXPERT OPINIONS: The DAA is established as one of exemplary approaches to THA. The use of fluoroscopy, the traction table, and appropriate soft tissue management has become essential in the DAA for a safe and trouble-free procedure with adequate patient comfort. With the combination of recent technologies such as robotics, three-dimensional preoperative planning, and artificial intelligence (AI)-based surgeon assist systems, we can look forward to the DAA being performed more efficiently in the future.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Cirujanos , Humanos , Inteligencia Artificial , Tracción , Estudios Retrospectivos
14.
Biochem Biophys Res Commun ; 418(4): 818-23, 2012 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-22326869

RESUMEN

Organic anion transporting polypeptide 1B3 (OATP1B3) is a hepatocyte plasma membrane protein that transports various endogenous and xenobiotic compounds. Although it is exclusively expressed in the human liver under normal conditions, OATP1B3 can be also expressed in various human cancer tissues that have been associated with prognosis and clinical outcomes. However, despite the potential significance of the latter finding, no experimental evidence addressing the molecular entity of cancer-associated OATP1B3 has been provided to date. In this paper, we report the identification of a new OATP1B3 mRNA isoform expressed in human colon and lung cancer tissues, which we named cancer-type OATP1B3 (Ct-OATP1B3). Our results also make known a previously unidentified transcription start site and an alternative promoter region, localized at intron 2, from which Ct-OATP1B3 mRNA is generated. Isoform specific mRNA quantification showed that the Ct-OATP1B3 mRNA level was strikingly higher than that of Lt-OATP1B3 mRNA in human cancer tissues. In addition, the results showed that the translation occurred at three out of four open reading frames. To summarize, our results clearly demonstrate that the newly-identified Ct-OATP1B3 (but not Lt-OATP1B3) is the primary mRNA isoform, at least in the human cancerous samples we have examined. In line with the possibility that its translation products play important biological roles in cancer cells, we strongly believe that the existence of Ct-OATP1B3 should be taken into account during future studies of OATP1B3 associated with cancer prognosis and clinical outcomes.


Asunto(s)
Biomarcadores de Tumor/biosíntesis , Neoplasias/metabolismo , Transportadores de Anión Orgánico Sodio-Independiente/biosíntesis , Isoformas de ARN/biosíntesis , ARN Mensajero/biosíntesis , Secuencia de Bases , Línea Celular Tumoral , Humanos , Datos de Secuencia Molecular , Sistemas de Lectura Abierta , Transportadores de Anión Orgánico Sodio-Independiente/genética , Biosíntesis de Proteínas , Isoformas de ARN/genética , ARN Mensajero/genética , Miembro 1B3 de la Familia de los Transportadores de Solutos de Aniones Orgánicos
15.
Injury ; 53(8): 2823-2831, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35768326

RESUMEN

AIMS: The acetabular morphology varies greatly among individuals, and hypoplasia is more common in Asia than in Europe. Dislocation after bipolar hip arthroplasty (BHA) for femoral neck fracture occurs at a constant rate, and is affected by the acetabular morphology. This study aimed to clarify individual differences in the acetabula of Asian patients with displaced femoral neck fractures. PATIENTS AND METHODS: Fifty patients with displaced femoral neck fractures were assessed (50 fractured hips, 50 non-fractured hips). On CT corrected by the anterior pelvic plane, the 100 hips were assessed regarding acetabular coverage (six parameters), acetabular depth (two parameters), and acetabular opening angle (four parameters). Additional parameters related to the fracture and sex were examined. The percentile of each parameter was shown for all hips. RESULTS: There was no patient with hip dysplasia defined as superior acetabular sector angle (SASA) less than 110° Compared with men, women had a significantly smaller anterior acetabular sector angle (AASA) (p = 0.016), and significantly larger acetabular inclination angle (p = 0.006) and acetabular index angle (p = 0.034). In the group with a normal SASA, seven hips (7.3%) had an anterior wall defect (AASA<50°) and five hips (5.2%) had a posterior wall defect (posterior acetabular sector angle<90°). CONCLUSION: Older adults with femoral neck fractures can have anterior wall and posterior wall defects, even if their SASA is normal. Hidden acetabular dysplasia may be related to post-BHA dislocation. So, our results suggest that is important to accurately evaluate the acetabulum of patients with femoral neck fracture before surgery.


Asunto(s)
Fracturas del Cuello Femoral , Luxación Congénita de la Cadera , Luxación de la Cadera , Anciano , Femenino , Humanos , Masculino , Acetábulo/anatomía & histología , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Fracturas del Cuello Femoral/diagnóstico por imagen , Fracturas del Cuello Femoral/cirugía , Luxación de la Cadera/diagnóstico por imagen , Luxación de la Cadera/cirugía , Luxación Congénita de la Cadera/cirugía , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
16.
Trauma Case Rep ; 31: 100381, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33426258

RESUMEN

INTRODUCTION: In recent years, it has been reported that periprosthetic femoral fractures in the form of atypical femoral fractures (AFFs) are found occasionally as difficult-to-treat conditions. To date, there have been no reports of interprosthetic femoral fractures (IPFFs) having the form of AFFs. We report a case of an atypical IPFF with breakage of the plate due to abnormal femoral alignment. CASE REPORT: A 70-year-old woman was admitted. She underwent left knee replacement and left hemi-arthroplasty at ages 61 and 60. And she had been taking bisphosphonate for 5 years. A plain X-ray revealed IPFF. The fracture was a complete transverse fracture with circumscribed thickening of the lateral cortical bone ("beak sign") at the fracture site. She underwent surgery. A reversed condylar locking compression plate (LCP) was used for internal fixation. Subsequently, she could walk without particular pain. Five months after the operation, she heard the snap of a bone breaking, and had difficulty walking. Plain X-ray revealed a re-fracture of the fracture site and breakage of the plate at the same high position. She underwent re-operation. A valgus osteotomy was performed at an angle of 15°. A reversed condylar LCP was used on the lateral side of the femur. A bone grafting was performed focusing on the fracture site. In addition, a short-LCP was fixed anteriorly to the femur. The bone union 1 year and 6 months postoperatively. She could walk, with no impairment being noted regarding ADL. CONCLUSIONS: We performed osteosynthesis for an IPFF having the characteristics of AFF, but the patient suffered breakage of the plate and re-fracture. Bone union was achieved as a result of re-operation that consisted of valgus osteotomy of the fracture site in combination with autologous bone grafting and double orthogonal plating.

17.
Surg Case Rep ; 7(1): 269, 2021 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-34928459

RESUMEN

BACKGROUND: Intra-abdominal hemorrhage caused by blunt hepatic injury is a major cause of morbidity and mortality in patients with abdominal trauma. Some of these patients require laparotomy, and rapid decision-making and life-saving surgery are essential. Damage control (DC) surgery is useful for treating children in critical situations. We performed this technique to treat an 8-year-old boy with grade IV blunt hepatic injury and multiple organ damage. This is the first report of the use of the ABTHERA Open Abdomen Negative Pressure Therapy System (KCI, now part of 3 M Company, San Antonio, TX, USA) for DC surgery to rescue a patient without neurological sequelae. CASE PRESENTATION: An 8-year-old boy was brought to the emergency department of our hospital after being run over by a motor vehicle. He had grade IV blunt hepatic injury, thyroid injury, and bilateral hemopneumothorax. Although he was hemodynamically stable, the patient's altered level of consciousness, the presence of a sign of peritoneal irritation, and suspicion of intestinal injury led us to perform exploratory laparotomy. As part of a DC strategy, we performed gauze packing to control hemorrhage from the liver and covered the abdomen with an ABTHERA Open Abdomen Negative Pressure Therapy System to improve the patient's general condition. Eighteen days after admission, the patient was diagnosed with a biliary fistula, which improved with percutaneous and external drainage. He had no neurological sequelae and was discharged 102 days after injury. CONCLUSION: The DC strategy was effective in children with severe blunt hepatic injury. We opted to perform DC surgery because children have less hemodynamic reserve than adults, and we believe that using this strategy before the appearance of trauma triad of death could save lives and improve outcomes. During conservative management, it is important to adopt a multistage, flexible approach to achieve a good outcome.

18.
Arthroplasty ; 3(1): 39, 2021 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-35236468

RESUMEN

BACKGROUND: A large-diameter femoral head is effective in preventing dislocation after total hip arthroplasty. However, although rare, catastrophic stem tribocorrosion may occur at the head-stem junction. CASE PRESENTATION: A 70-year-old woman underwent revision surgery 7.5 years after total hip arthroplasty because of catastrophic stem corrosion with dissociation of the metal head (cobalt/chromium) and stem (TiMo12Zr6Fe2). Abnormal levels of cobalt were found in the intra-articular fluid, capsule, hip muscle, and blood. Revision surgery was performed via the direct anterior approach. The well-fixed femoral stem was explanted, and a cemented stainless stem with stainless head was implanted. Three months after the revision surgery, the cobalt concentration in the blood had decreased to normal. CONCLUSIONS: Stem dissociation in the present case might have been caused by synergistic combination of a 36-mm-diameter femoral head and long neck length offset with high frictional torque, a cobalt-chromium head with a high risk of galvanic corrosion, and a TMZF (TiMo12Zr6Fe2) alloy stem with a low Young's modulus of elasticity. The combination of these factors must be avoided.

19.
Arthroplasty ; 3(1): 2, 2021 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-35236437

RESUMEN

BACKGROUND: Total hip arthroplasty (THA) via the direct anterior approach (DAA) using dual mobility cup (DMC) is considered to effectively prevent postoperative dislocation. However, the dislocation and reduction procedure using a trial implant during the surgery is difficult because of high soft tissue tension. Thereby, leg length discrepancy (LLD) is difficult to assess when using DM via the DAA. PURPOSE: To compare the LLD between cases using conventional SM and those using DMC in THA via the DAA with fluoroscopy. PATIENTS AND METHODS: We retrospectively investigated 34 hips treated with DMC (DMC-DAA group) and 31 hips treated with SM (SM-DAA group). The LLD was defined as the difference in the distance from the teardrop to the medial-most point of the lesser trochanter between the operative and nonoperative sides at immediate postoperative X-ray. RESULTS: The mean LLD in the DMC-DAA group and SM-DAA group was 0.68 ± 7.7 mm and 0.80 ± 5.5, respectively, with no significant difference. The absolute value of the LLD in the DMC-DAA group and SM-DAA group was 6.3 ± 4.4 mm and 5.9 ± 5.5, respectively, with no significant difference. CONCLUSION: Despite the difficulty in assessment of the LLD during THA via the DAA using DMC, this technique does not increase the LLD compared with the use of SM. LEVEL OF EVIDENCE: III, matched case-control study.

20.
Yakugaku Zasshi ; 140(9): 1141-1150, 2020.
Artículo en Japonés | MEDLINE | ID: mdl-32879246

RESUMEN

Osteoarthritis is the most common joint disorder worldwide and one of the leading causes of disability in the elderly. We have reported that the novel sodium hyaluronate derivative chemically linked with diclofenac (DF), diclofenac etalhyaluronate (SI-613), exerted a potent and long-lasting analgesic effect in experimental arthritis models. In this study, we evaluated the properties of residual SI-613 in the knee joint after an intra-articular (IA) administration. After IA administration of fluorescent labeled SI-613 (FA-SI-613) or fluorescent labeled hyaluronic acid (FA-HA) to rabbits, fluorescence intensities in the synovial membrane and cartilage were higher in the FA-SI-613 group until 7 d after administration than in the FA-HA group. After IA administration of radiolabeled SI-613 (14C-SI-613) to rabbits, the radioactivity remained in the joint cavity and the joint tissues such as synovial membrane and cartilage until 84 d after administration. This residual radioactivity was identified mainly as HA linked with DF, since 14C-SI-613 was labeled at the benzene ring of DF and since more DF-linked HA oligomer was detected on metabolite analysis than free DF in the synovial membrane and synovial lavage fluid up to 28 d after administration. These results suggested that intra-articularly administered SI-613 remained for a longer time in the joint as HA linked with DF than when HA was administered. Therefore, SI-613 was considered to prolong the pharmacological effects of both HA and DF by remaining in the joint as HA linked with DF.


Asunto(s)
Diclofenaco/administración & dosificación , Diclofenaco/metabolismo , Ácido Hialurónico/análogos & derivados , Articulación de la Rodilla , Osteoartritis/tratamiento farmacológico , Animales , Cartílago/metabolismo , Modelos Animales de Enfermedad , Ácido Hialurónico/administración & dosificación , Ácido Hialurónico/metabolismo , Inyecciones Intraarticulares , Articulación de la Rodilla/metabolismo , Masculino , Conejos , Membrana Sinovial/metabolismo , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA