Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Dermatol ; 50(2): 262-265, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36217779

RESUMEN

Palisaded neutrophilic and granulomatous dermatitis (PNGD) is a relatively rare skin disease that is characterized by a reactive granulomatous histopathological pattern and is often associated with systemic autoimmune diseases. We encountered a case of PNGD that presented with pustules, although the prototypical clinical presentation of PNGD is mainly erythema and papules. Here, this rare case of PNGD with pustules is presented and discussed in relation to the relevant literature.


Asunto(s)
Dermatitis , Lupus Eritematoso Sistémico , Enfermedades de la Piel , Humanos , Dermatitis/etiología , Dermatitis/complicaciones , Enfermedades de la Piel/patología , Piel/patología , Lupus Eritematoso Sistémico/complicaciones , Lupus Eritematoso Sistémico/diagnóstico , Lupus Eritematoso Sistémico/patología , Vesícula/patología
2.
Eplasty ; 17: e39, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29308107

RESUMEN

Objective: Preoperative prediction of breast volume is important in the planning of breast reconstructive surgery. In this study, we prospectively estimated the accuracy of measurement of breast volume using data from 2 routine modalities, mammography and magnetic resonance imaging, by comparison with volumes of mastectomy specimens. Methods: The subjects were 22 patients (24 breasts) who were scheduled to undergo total mastectomy for breast cancer. Preoperatively, magnetic resonance imaging volume measurement was performed using a medical imaging system and the mammographic volume was calculated using a previously proposed formula. Volumes of mastectomy specimens were measured intraoperatively using a method based on Archimedes' principle and Newton's third law. Results: The average breast volumes measured on magnetic resonance imaging and mammography were 318.47 ± 199.4 mL and 325.26 ± 217.36 mL, respectively. The correlation coefficients with mastectomy specimen volumes were 0.982 for magnetic resonance imaging and 0.911 for mammography. Conclusions: Breast volume measurement using magnetic resonance imaging was highly accurate but requires data analysis software. In contrast, breast volume measurement with mammography requires only a simple formula and is sufficiently accurate, although the accuracy was lower than that obtained with magnetic resonance imaging. These results indicate that mammography could be an alternative modality for breast volume measurement as a substitute for magnetic resonance imaging.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA