Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38881496

RESUMEN

BACKGROUND: Artificial intelligence, particularly deep learning (DL), has immense potential to improve the interpretation of transthoracic echocardiography (TTE). Mitral regurgitation (MR) is the most common valvular heart disease and presents unique challenges for DL, including the integration of multiple video-level assessments into a final study-level classification. METHODS: A novel DL system was developed to intake complete TTEs, identify color MR Doppler videos, and determine MR severity on a 4-step ordinal scale (none/trace, mild, moderate, and severe) using the reading cardiologist as a reference standard. This DL system was tested in internal and external test sets with performance assessed by agreement with the reading cardiologist, weighted κ, and area under the receiver-operating characteristic curve for binary classification of both moderate or greater and severe MR. In addition to the primary 4-step model, a 6-step MR assessment model was studied with the addition of the intermediate MR classes of mild-moderate and moderate-severe with performance assessed by both exact agreement and ±1 step agreement with the clinical MR interpretation. RESULTS: A total of 61 689 TTEs were split into train (n=43 811), validation (n=8891), and internal test (n=8987) sets with an additional external test set of 8208 TTEs. The model had high performance in MR classification in internal (exact accuracy, 82%; κ=0.84; area under the receiver-operating characteristic curve, 0.98 for moderate/severe MR) and external test sets (exact accuracy, 79%; κ=0.80; area under the receiver-operating characteristic curve, 0.98 for moderate or greater MR). Most (63% internal and 66% external) misclassification disagreements were between none/trace and mild MR. MR classification accuracy was slightly higher using multiple TTE views (accuracy, 82%) than with only apical 4-chamber views (accuracy, 80%). In subset analyses, the model was accurate in the classification of both primary and secondary MR with slightly lower performance in cases of eccentric MR. In the analysis of the 6-step classification system, the exact accuracy was 80% and 76% with a ±1 step agreement of 99% and 98% in the internal and external test set, respectively. CONCLUSIONS: This end-to-end DL system can intake entire echocardiogram studies to accurately classify MR severity and may be useful in helping clinicians refine MR assessments.

2.
Circulation ; 146(1): 36-47, 2022 07 05.
Artículo en Inglés | MEDLINE | ID: mdl-35533093

RESUMEN

BACKGROUND: Timely diagnosis of structural heart disease improves patient outcomes, yet many remain underdiagnosed. While population screening with echocardiography is impractical, ECG-based prediction models can help target high-risk patients. We developed a novel ECG-based machine learning approach to predict multiple structural heart conditions, hypothesizing that a composite model would yield higher prevalence and positive predictive values to facilitate meaningful recommendations for echocardiography. METHODS: Using 2 232 130 ECGs linked to electronic health records and echocardiography reports from 484 765 adults between 1984 to 2021, we trained machine learning models to predict the presence or absence of any of 7 echocardiography-confirmed diseases within 1 year. This composite label included the following: moderate or severe valvular disease (aortic/mitral stenosis or regurgitation, tricuspid regurgitation), reduced ejection fraction <50%, or interventricular septal thickness >15 mm. We tested various combinations of input features (demographics, laboratory values, structured ECG data, ECG traces) and evaluated model performance using 5-fold cross-validation, multisite validation trained on 1 site and tested on 10 independent sites, and simulated retrospective deployment trained on pre-2010 data and deployed in 2010. RESULTS: Our composite rECHOmmend model used age, sex, and ECG traces and had a 0.91 area under the receiver operating characteristic curve and a 42% positive predictive value at 90% sensitivity, with a composite label prevalence of 17.9%. Individual disease models had area under the receiver operating characteristic curves from 0.86 to 0.93 and lower positive predictive values from 1% to 31%. Area under the receiver operating characteristic curves for models using different input features ranged from 0.80 to 0.93, increasing with additional features. Multisite validation showed similar results to cross-validation, with an aggregate area under the receiver operating characteristic curve of 0.91 across our independent test set of 10 clinical sites after training on a separate site. Our simulated retrospective deployment showed that for ECGs acquired in patients without preexisting structural heart disease in the year 2010, 11% were classified as high risk and 41% (4.5% of total patients) developed true echocardiography-confirmed disease within 1 year. CONCLUSIONS: An ECG-based machine learning model using a composite end point can identify a high-risk population for having undiagnosed, clinically significant structural heart disease while outperforming single-disease models and improving practical utility with higher positive predictive values. This approach can facilitate targeted screening with echocardiography to improve underdiagnosis of structural heart disease.


Asunto(s)
Cardiopatías , Aprendizaje Automático , Adulto , Ecocardiografía , Electrocardiografía , Cardiopatías/diagnóstico por imagen , Cardiopatías/epidemiología , Humanos , Estudios Retrospectivos
3.
J Electrocardiol ; 76: 61-65, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36436476

RESUMEN

BACKGROUND: Several large trials have employed age or clinical features to select patients for atrial fibrillation (AF) screening to reduce strokes. We hypothesized that a machine learning (ML) model trained to predict AF risk from 12­lead electrocardiogram (ECG) would be more efficient than criteria based on clinical variables in indicating a population for AF screening to potentially prevent AF-related stroke. METHODS: We retrospectively included all patients with clinical encounters in Geisinger without a prior history of AF. Incidence of AF within 1 year and AF-related strokes within 3 years of the encounter were identified. AF-related stroke was defined as a stroke where AF was diagnosed at the time of stroke or within a year after the stroke. The efficiency of five methods was evaluated for selecting a cohort for AF screening. The methods were selected from four clinical trials (mSToPS, GUARD-AF, SCREEN-AF and STROKESTOP) and the ECG-based ML model. We simulated patient selection for the five methods between the years 2011 and 2014 and evaluated outcomes for 1 year intervals between 2012 and 2015, resulting in a total of twenty 1-year periods. Patients were considered eligible if they met the criteria before the start of the given 1-year period or within that period. The primary outcomes were numbers needed to screen (NNS) for AF and AF-associated stroke. RESULTS: The clinical trial models indicated large proportions of the population with a prior ECG for AF screening (up to 31%), coinciding with NNS ranging from 14 to 18 for AF and 249-359 for AF-associated stroke. At comparable sensitivity, the ECG ML model indicated a modest number of patients for screening (14%) and had the highest efficiency in NNS for AF (7.3; up to 60% reduction) and AF-associated stroke (223; up to 38% reduction). CONCLUSIONS: An ECG-based ML risk prediction model is more efficient than contemporary AF-screening criteria based on age alone or age and clinical features at indicating a population for AF screening to potentially prevent AF-related strokes.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Electrocardiografía , Estudios Retrospectivos , Tamizaje Masivo , Accidente Cerebrovascular/diagnóstico
4.
Circulation ; 143(13): 1287-1298, 2021 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-33588584

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is associated with substantial morbidity, especially when it goes undetected. If new-onset AF could be predicted, targeted screening could be used to find it early. We hypothesized that a deep neural network could predict new-onset AF from the resting 12-lead ECG and that this prediction may help identify those at risk of AF-related stroke. METHODS: We used 1.6 M resting 12-lead digital ECG traces from 430 000 patients collected from 1984 to 2019. Deep neural networks were trained to predict new-onset AF (within 1 year) in patients without a history of AF. Performance was evaluated using areas under the receiver operating characteristic curve and precision-recall curve. We performed an incidence-free survival analysis for a period of 30 years following the ECG stratified by model predictions. To simulate real-world deployment, we trained a separate model using all ECGs before 2010 and evaluated model performance on a test set of ECGs from 2010 through 2014 that were linked to our stroke registry. We identified the patients at risk for AF-related stroke among those predicted to be high risk for AF by the model at different prediction thresholds. RESULTS: The area under the receiver operating characteristic curve and area under the precision-recall curve were 0.85 and 0.22, respectively, for predicting new-onset AF within 1 year of an ECG. The hazard ratio for the predicted high- versus low-risk groups over a 30-year span was 7.2 (95% CI, 6.9-7.6). In a simulated deployment scenario, the model predicted new-onset AF at 1 year with a sensitivity of 69% and specificity of 81%. The number needed to screen to find 1 new case of AF was 9. This model predicted patients at high risk for new-onset AF in 62% of all patients who experienced an AF-related stroke within 3 years of the index ECG. CONCLUSIONS: Deep learning can predict new-onset AF from the 12-lead ECG in patients with no previous history of AF. This prediction may help identify patients at risk for AF-related strokes.


Asunto(s)
Fibrilación Atrial/diagnóstico , Aprendizaje Profundo/normas , Accidente Cerebrovascular/etiología , Fibrilación Atrial/complicaciones , Electrocardiografía , Femenino , Humanos , Masculino , Redes Neurales de la Computación , Accidente Cerebrovascular/mortalidad , Análisis de Supervivencia
5.
Eur Heart J ; 41(12): 1249-1257, 2020 03 21.
Artículo en Inglés | MEDLINE | ID: mdl-31386109

RESUMEN

AIMS: We investigated the relationship between clinically assessed left ventricular ejection fraction (LVEF) and survival in a large, heterogeneous clinical cohort. METHODS AND RESULTS: Physician-reported LVEF on 403 977 echocardiograms from 203 135 patients were linked to all-cause mortality using electronic health records (1998-2018) from US regional healthcare system. Cox proportional hazards regression was used for analyses while adjusting for many patient characteristics including age, sex, and relevant comorbidities. A dataset including 45 531 echocardiograms and 35 976 patients from New Zealand was used to provide independent validation of analyses. During follow-up of the US cohort, 46 258 (23%) patients who had undergone 108 578 (27%) echocardiograms died. Overall, adjusted hazard ratios (HR) for mortality showed a u-shaped relationship for LVEF with a nadir of risk at an LVEF of 60-65%, a HR of 1.71 [95% confidence interval (CI) 1.64-1.77] when ≥70% and a HR of 1.73 (95% CI 1.66-1.80) at LVEF of 35-40%. Similar relationships with a nadir at 60-65% were observed in the validation dataset as well as for each age group and both sexes. The results were similar after further adjustments for conditions associated with an elevated LVEF, including mitral regurgitation, increased wall thickness, and anaemia and when restricted to patients reported to have heart failure at the time of the echocardiogram. CONCLUSION: Deviation of LVEF from 60% to 65% is associated with poorer survival regardless of age, sex, or other relevant comorbidities such as heart failure. These results may herald the recognition of a new phenotype characterized by supra-normal LVEF.


Asunto(s)
Insuficiencia Cardíaca , Función Ventricular Izquierda , Femenino , Humanos , Masculino , Nueva Zelanda/epidemiología , Pronóstico , Modelos de Riesgos Proporcionales , Factores de Riesgo , Volumen Sistólico
6.
J Cardiovasc Magn Reson ; 20(1): 63, 2018 09 13.
Artículo en Inglés | MEDLINE | ID: mdl-30208894

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) feature tracking is increasingly used to quantify cardiac mechanics from cine CMR imaging, although validation against reference standard techniques has been limited. Furthermore, studies have suggested that commonly-derived metrics, such as peak global strain (reported in 63% of feature tracking studies), can be quantified using contours from just two frames - end-diastole (ED) and end-systole (ES) - without requiring tracking software. We hypothesized that mechanics derived from feature tracking would not agree with those derived from a reference standard (displacement-encoding with stimulated echoes (DENSE) imaging), and that peak strain from feature tracking would agree with that derived using simple processing of only ED and ES contours. METHODS: We retrospectively identified 88 participants with 186 pairs of DENSE and balanced steady state free precession (bSSFP) image slices acquired at the same locations across two institutions. Left ventricular (LV) strains, torsion, and dyssynchrony were quantified from both feature tracking (TomTec Imaging Systems, Circle Cardiovascular Imaging) and DENSE. Contour-based strains from bSSFP images were derived from ED and ES contours. Agreement was assessed with Bland-Altman analyses and coefficients of variation (CoV). All biases are reported in absolute percentage. RESULTS: Comparison results were similar for both vendor packages (TomTec and Circle), and thus only TomTec Imaging System data are reported in the abstract for simplicity. Compared to DENSE, mid-ventricular circumferential strain (Ecc) from feature tracking had acceptable agreement (bias: - 0.4%, p = 0.36, CoV: 11%). However, feature tracking significantly overestimated the magnitude of Ecc at the base (bias: - 4.0% absolute, p < 0.001, CoV: 18%) and apex (bias: - 2.4% absolute, p = 0.01, CoV: 15%), underestimated torsion (bias: - 1.4 deg/cm, p < 0.001, CoV: 41%), and overestimated dyssynchrony (bias: 26 ms, p < 0.001, CoV: 76%). Longitudinal strain (Ell) had borderline-acceptable agreement (bias: - 0.2%, p = 0.77, CoV: 19%). Contour-based strains had excellent agreement with feature tracking (biases: - 1.3-0.2%, CoVs: 3-7%). CONCLUSION: Compared to DENSE as a reference standard, feature tracking was inaccurate for quantification of apical and basal LV circumferential strains, longitudinal strain, torsion, and dyssynchrony. Feature tracking was only accurate for quantification of mid LV circumferential strain. Moreover, feature tracking is unnecessary for quantification of whole-slice strains (e.g. base, apex), since simplified processing of only ED and ES contours yields very similar results to those derived from feature tracking. Current feature tracking technology therefore has limited utility for quantification of cardiac mechanics.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Contracción Miocárdica , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Adolescente , Adulto , Fenómenos Biomecánicos , Niño , Bases de Datos Factuales , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/normas , Kentucky , Imagen por Resonancia Cinemagnética/normas , Masculino , Philadelphia , Valor Predictivo de las Pruebas , Estándares de Referencia , Reproducibilidad de los Resultados , Estudios Retrospectivos , Torsión Mecánica , Disfunción Ventricular Izquierda/fisiopatología , Adulto Joven
7.
J Cardiovasc Magn Reson ; 20(1): 32, 2018 05 21.
Artículo en Inglés | MEDLINE | ID: mdl-29783986

RESUMEN

BACKGROUND: In addition to tricuspid regurgitation (TR) and right ventricular (RV) enlargement, patients with Ebstein anomaly are at risk for left ventricular (LV) dysfunction and dyssynchrony. We studied the impact of the cone tricuspid valve reconstruction operation on LV size, function, and dyssynchrony. METHODS: All Ebstein anomaly patients who had both pre- and postoperative cardiovascular magnetic resonance (CMR) studies were retrospectively identified. From cine images, RV and LV volumes and ejection fractions (EF) were calculated, and LV circumferential and longitudinal strain were measured by feature tracking. To quantify LV dyssynchrony, temporal offsets (TOs) were computed among segmental circumferential strain versus time curves using cross-correlation analysis and patient-specific reference curves. An LV dyssynchrony index was calculated as the standard deviation of the TOs. RESULTS: Twenty patients (65% female) were included with a median age at cone operation of 16 years, and a median time between pre- and postoperative CMR of 2.8 years. Postoperatively, there was a decline in the TR fraction (56 ± 19% vs. 5 ± 4%, p < 0.001), RV end-diastolic volume (EDV) (242 ± 110 ml/m2 vs. 137 ± 82 ml/m2, p < 0.001), and RV stroke volume (SV) (101 ± 35 vs. 51 ± 7 ml/m2, p < 0.001). RV EF was unchanged. Conversely, there was an increase in both LV EDV (68 ± 13 vs. 85 ± 13 ml/m2, p < 0.001) and LV stroke volume (37 ± 8 vs. 48 ± 6 ml/m2, p < 0.001). There was no change in LV EF, or global circumferential and longitudinal strain but basal septal circumferential strain improved (16 ± 7% vs. 22 ± 5%, p = 0.04). LV contraction become more synchronous (dyssynchrony index: 32 ± 17 vs. 21 ± 9 msec, p = 0.02), and the extent correlated with the reduction in RV EDV and TR. CONCLUSIONS: In patients with the Ebstein anomaly, the cone operation led to reduced TR and RV stroke volume, increased LV stroke volume, improved LV basal septal strain, and improved LV synchrony. Our data demonstrates that the detrimental effect of the RV on LV function can be mitigated by the cone operation.


Asunto(s)
Anomalía de Ebstein/cirugía , Ventrículos Cardíacos/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Contracción Miocárdica , Válvula Tricúspide/cirugía , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Adolescente , Adulto , Procedimientos Quirúrgicos Cardíacos , Niño , Preescolar , Anomalía de Ebstein/diagnóstico por imagen , Anomalía de Ebstein/fisiopatología , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Valor Predictivo de las Pruebas , Recuperación de la Función , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Válvula Tricúspide/anomalías , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/fisiopatología , Función Ventricular Derecha , Adulto Joven
8.
J Cardiovasc Magn Reson ; 19(1): 100, 2017 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-29228952

RESUMEN

BACKGROUND: Patients with repaired tetralogy of Fallot (TOF) have progressive, adverse biventricular remodeling, leading to abnormal contractile mechanics. Defining the mechanisms underlying this dysfunction, such as diffuse myocardial fibrosis, may provide insights into poor long-term outcomes. We hypothesized that left ventricular (LV) diffuse fibrosis is related to impaired LV mechanics. METHODS: Patients with TOF were evaluated with cardiac magnetic resonance in which modified Look-Locker (MOLLI) T1-mapping and spiral cine Displacement encoding (DENSE) sequences were acquired at three LV short-axis positions. Linear mixed modeling was used to define the association between regional LV mechanics from DENSE based on regional T1-derived diffuse fibrosis measures, such as extracellular volume fraction (ECV). RESULTS: Forty patients (26 ± 11 years) were included. LV ECV was generally within normal range (0.24 ± 0.05). For LV mechanics, peak circumferential strains (-15 ± 3%) and dyssynchrony indices (16 ± 8 ms) were moderately impaired, while peak radial strains (29 ± 8%) were generally normal. After adjusting for patient age, sex, and regional LV differences, ECV was associated with log-adjusted LV dyssynchrony index (ß = 0.67) and peak LV radial strain (ß = -0.36), but not LV circumferential strain. Moreover, post-contrast T1 was associated with log-adjusted LV diastolic circumferential strain rate (ß = 0.37). CONCLUSIONS: We observed several moderate associations between measures of fibrosis and impaired mechanics, particularly the LV dyssynchrony index and peak radial strain. Diffuse fibrosis may therefore be a causal factor in some ventricular dysfunction in TOF.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Contracción Miocárdica , Miocardio/patología , Tetralogía de Fallot/cirugía , Disfunción Ventricular Izquierda/etiología , Función Ventricular Izquierda , Remodelación Ventricular , Adolescente , Adulto , Fenómenos Biomecánicos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Estudios Transversales , Femenino , Fibrosis , Humanos , Imagen por Resonancia Cinemagnética , Masculino , Factores de Riesgo , Tetralogía de Fallot/complicaciones , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Adulto Joven
9.
J Cardiovasc Magn Reson ; 19(1): 49, 2017 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-28659144

RESUMEN

BACKGROUND: Pediatric obesity is a growing public health problem, which is associated with increased risk of cardiovascular disease and premature death. Left ventricular (LV) remodeling (increased myocardial mass and thickness) and contractile dysfunction (impaired longitudinal strain) have been documented in obese children, but little attention has been paid to the right ventricle (RV). We hypothesized that obese/overweight children would have evidence of RV remodeling and contractile dysfunction. METHODS: One hundred and three children, ages 8-18 years, were prospectively recruited and underwent cardiovascular magnetic resonance (CMR), including both standard cine imaging and displacement encoding with stimulated echoes (DENSE) imaging, which allowed for quantification of RV geometry and function/mechanics. RV free wall longitudinal strain was quantified from the end-systolic four-chamber DENSE image. Linear regression was used to quantify correlations of RV strain with LV strain and measurements of body composition (adjusted for sex and height). Analysis of variance was used to study the relationship between RV strain and LV remodeling types (concentric remodeling, eccentric/concentric hypertrophy). RESULTS: The RV was sufficiently visualized with DENSE in 70 (68%) subjects, comprising 36 healthy weight (13.6 ± 2.7 years) and 34 (12.1 ± 2.9 years) obese/overweight children. Obese/overweight children had a 22% larger RV mass index (8.2 ± 0.9 vs 6.7 ± 1.1 g/m2.7, p < 0.001) compared to healthy controls. RV free wall longitudinal strain was impaired in obese/overweight children (-16 ± 4% vs -19 ± 5%, p = 0.02). Ten (14%) out of 70 children had LV concentric hypertrophy, and these children had the most impaired RV longitudinal strain compared to those with normal LV geometry (-13 ± 4% vs -19 ± 5%, p = 0.002). RV longitudinal strain was correlated with LV longitudinal strain (r = 0.34, p = 0.004), systolic blood pressure (r = 0.33, p = 0.006), as well as BMI z-score (r = 0.28, p = 0.02), waist (r = 0.31, p = 0.01), hip (r = 0.40, p = 0.004) and abdominal (r = 0.38, p = 0.002) circumference, height and sex adjusted. CONCLUSIONS: Obese/overweight children have evidence of RV remodeling (increased RV mass) and RV contractile dysfunction (impaired free wall longitudinal strain). Moreover, RV longitudinal strain correlates with LV longitudinal strain, and children with LV concentric hypertrophy show the most impaired RV function. These results suggest there may be a common mechanism underlying both remodeling and dysfunction of the left and right ventricles in obese/overweight children.


Asunto(s)
Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Contracción Miocárdica , Obesidad Infantil/complicaciones , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Derecha/diagnóstico por imagen , Función Ventricular Izquierda , Función Ventricular Derecha , Remodelación Ventricular , Adolescente , Niño , Femenino , Humanos , Hipertrofia Ventricular Izquierda/etiología , Hipertrofia Ventricular Izquierda/fisiopatología , Interpretación de Imagen Asistida por Computador , Kentucky , Modelos Lineales , Masculino , Variaciones Dependientes del Observador , Obesidad Infantil/diagnóstico , Obesidad Infantil/fisiopatología , Pennsylvania , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Derecha/etiología , Disfunción Ventricular Derecha/fisiopatología
10.
J Cardiovasc Magn Reson ; 19(1): 86, 2017 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-29117866

RESUMEN

BACKGROUND: Children with obesity have hypertrophic cardiac remodeling. Hypertension is common in pediatric obesity, and may independently contribute to hypertrophy. We hypothesized that both the degree of obesity and ambulatory blood pressure (ABP) would independently associate with measures of hypertrophic cardiac remodeling in children. METHODS: Children, aged 8-17 years, prospectively underwent cardiovascular magnetic resonance (CMR) and ABP monitoring. Left ventricular (LV) mass indexed to height2.7 (LVMI), myocardial thickness and end-diastolic volume were quantified from a 3D LV model reconstructed from cine balanced steady state free precession images. Categories of remodeling were determined based on cutoff values for LVMI and mass/volume. Principal component analysis was used to define a "hypertrophy score" to study the continuous relationship between concentric hypertrophy and ABP. RESULTS: Seventy-two children were recruited, and 68 of those (37 healthy weight and 31 obese/overweight) completed both CMR and ABP monitoring. Obese/overweight children had increased LVMI (27 ± 4 vs 22 ± 3 g/m2.7, p < 0.001), myocardial thickness (5.6 ± 0.9 vs 4.9 ± 0.7 mm, p < 0.001), mass/volume (0.69 ± 0.1 vs 0.61 ± 0.06, p < 0.001), and hypertrophy score (1.1 ± 2.2 vs -0.96 ± 1.1, p < 0.001). Thirty-five percent of obese/overweight children had concentric hypertrophy. Ambulatory hypertension was observed in 26% of the obese/overweight children and none of the controls while masked hypertension was observed in 32% of the obese/overweight children and 16% of the controls. Univariate linear regression showed that BMI z-score, systolic BP (24 h, day and night), and systolic load correlated with LVMI, thickness, mass/volume and hypertrophy score, while 24 h and nighttime diastolic BP and load also correlated with thickness and mass/volume. Multivariate analysis showed body mass index z-score and systolic blood pressure were both independently associated with left ventricular mass index (ß=0.54 [p < 0.001] and 0.22 [p = 0.03]), thickness (ß=0.34 [p < 0.001] and 0.26 [p = 0.001]) and hypertrophy score (ß=0.47 and 0.36, both p < 0.001). CONCLUSIONS: In children, both the degree of obesity and ambulatory blood pressures are independently associated with measures of cardiac hypertrophic remodeling, however the correlations were generally stronger for the degree of obesity. This suggests that interventions targeted at weight loss or obesity-associated co-morbidities including hypertension may be effective in reversing or preventing cardiac remodeling in obese children.


Asunto(s)
Presión Sanguínea , Hipertensión/etiología , Hipertrofia Ventricular Izquierda/etiología , Obesidad Infantil/complicaciones , Función Ventricular Izquierda , Remodelación Ventricular , Adolescente , Factores de Edad , Monitoreo Ambulatorio de la Presión Arterial , Índice de Masa Corporal , Distribución de Chi-Cuadrado , Niño , Estudios Transversales , Femenino , Humanos , Hipertensión/diagnóstico , Hipertensión/fisiopatología , Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Hipertrofia Ventricular Izquierda/fisiopatología , Modelos Lineales , Imagen por Resonancia Cinemagnética , Masculino , Análisis Multivariante , Obesidad Infantil/diagnóstico , Obesidad Infantil/fisiopatología , Análisis de Componente Principal , Estudios Prospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad
11.
J Cardiovasc Magn Reson ; 18(1): 28, 2016 05 11.
Artículo en Inglés | MEDLINE | ID: mdl-27165194

RESUMEN

BACKGROUND: Obesity affects nearly one in five children and is associated with increased risk of premature death. Obesity-related heart disease contributes to premature death. We aimed to use cardiovascular magnetic resonance (CMR) to comprehensively characterize the changes in cardiac geometry and function in obese children. METHODS AND RESULTS: Forty-one obese/overweight (age 12 ± 3 years, 56 % female) and 29 healthy weight children (age 14 ± 3 years, 41 % female) underwent CMR, including both standard cine imaging and displacement encoded imaging, for a complete assessment of left ventricular (LV) structure and function. After adjusting for age, LV mass index was 23 % greater (27 ± 4 g/m(2.7) vs 22 ± 3 g/m(2.7), p <0.001) and the LV myocardium was 10 % thicker (5.6 ± 0.8 mm vs 5.1 ± 0.8 mm, p <0.001) in the obese/overweight children. This evidence of cardiac remodeling was present in obese children as young as age 8. Twenty four percent of obese/overweight children had concentric hypertrophy, 59 % had normal geometry and 17 % had either eccentric hypertrophy or concentric remodeling. LV mass index, thickness, ejection fraction and peak longitudinal and circumferential strains all correlated with epicardial adipose tissue after adjusting for height and gender (all p <0.05). Peak longitudinal and circumferential strains showed a significant relationship with the type of LV remodeling, and were most impaired in children with concentric hypertrophy (p <0.001 and p = 0.003, respectively). CONCLUSIONS: Obese children show evidence of significant cardiac remodeling and dysfunction, which begins as young as age 8. Obese children with concentric hypertrophy and impaired strain may represent a particularly high risk subgroup that demands further investigation.


Asunto(s)
Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Obesidad Infantil/complicaciones , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Remodelación Ventricular , Adiposidad , Adolescente , Edad de Inicio , Fenómenos Biomecánicos , Estudios de Casos y Controles , Niño , Estudios Transversales , Femenino , Humanos , Hipertrofia Ventricular Izquierda/etiología , Hipertrofia Ventricular Izquierda/fisiopatología , Masculino , Contracción Miocárdica , Variaciones Dependientes del Observador , Obesidad Infantil/fisiopatología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Factores de Riesgo , Estrés Mecánico , Volumen Sistólico , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/fisiopatología
12.
J Cardiovasc Magn Reson ; 18(1): 49, 2016 08 22.
Artículo en Inglés | MEDLINE | ID: mdl-27549809

RESUMEN

BACKGROUND: Patients with repaired tetralogy of Fallot (rTOF) suffer from progressive ventricular dysfunction decades after their surgical repair. We hypothesized that measures of ventricular strain and dyssynchrony would predict deterioration of ventricular function in patients with rTOF. METHODS: A database search identified all patients at a single institution with rTOF who underwent cardiovascular magnetic resonance (CMR) at least twice, >6 months apart, without intervening surgical or catheter procedures. Seven primary predictors were derived from the first CMR using a custom feature tracking algorithm: left (LV), right (RV) and inter-ventricular dyssynchrony, LV and RV peak global circumferential strains, and LV and RV peak global longitudinal strains. Three outcomes were defined, whose changes were assessed over time: RV end-diastolic volume, and RV and LV ejection fraction. Multivariate linear mixed models were fit to investigate relationships of outcomes to predictors and ten potential baseline confounders. RESULTS: One hundred fifty-three patients with rTOF (23 ± 14 years, 50 % male) were included. The mean follow-up duration between the first and last CMR was 2.9 ± 1.3 years. After adjustment for confounders, none of the 7 primary predictors were significantly associated with change over time in the 3 outcome variables. Only 1-17 % of the variability in the change over time in the outcome variables was explained by the baseline predictors and potential confounders. CONCLUSIONS: In patients with repaired tetralogy of Fallot, ventricular dyssynchrony and global strain derived from cine CMR were not significantly related to changes in ventricular size and function over time. The ability to predict deterioration in ventricular function in patients with rTOF using current methods is limited.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Imagen por Resonancia Cinemagnética , Tetralogía de Fallot/cirugía , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Derecha/diagnóstico por imagen , Función Ventricular Izquierda , Función Ventricular Derecha , Adolescente , Algoritmos , Fenómenos Biomecánicos , Niño , Bases de Datos Factuales , Progresión de la Enfermedad , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Kentucky , Modelos Lineales , Masculino , Análisis Multivariante , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Estrés Mecánico , Volumen Sistólico , Tetralogía de Fallot/complicaciones , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Derecha/etiología , Disfunción Ventricular Derecha/fisiopatología , Adulto Joven
13.
J Cardiovasc Magn Reson ; 17: 90, 2015 Oct 29.
Artículo en Inglés | MEDLINE | ID: mdl-26520782

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) of ventricular structure and function is widely performed using cine balanced steady state free precession (bSSFP) MRI. The bSSFP signal of myocardium is weighted by magnetization transfer (MT) and T1/T2-relaxation times. In edematous and fibrotic tissues, increased T2 and reduced MT lead to increased signal intensity on images acquired with high excitation flip angles. We hypothesized that acquisition of two differentially MT-weighted bSSFP images (termed 2-point bSSFP) can identify tissue that would enhance with gadolinium similar to standard of care late gadolinium enhancement (LGE). METHODS: Cine bSSFP images (flip angles of 5° and 45°) and native-T1 and T2 maps were acquired in one mid-ventricular slice in 47 patients referred for CMR and 10 healthy controls. Afterwards, LGE images and post-contrast T1 maps were acquired and gadolinium partition coefficient (GPC) was calculated. Maps of ΔS/So were calculated as (S45-S5)/S5*100 (%), where Sflip_angle is the voxel signal intensity. RESULTS: Twenty three patients demonstrated areas of myocardial hyper-enhancement with LGE. In enhanced regions, ΔS/So, native-T1, T2, and GPC were heightened (p < 0.05 vs. non-enhanced tissues). ΔS/So, native-T1, and T2 all demonstrated association with GPC, however the association was strongest for ΔS/So. Bland-Altman analysis revealed a slight bias towards larger volume of enhancement with ΔS/So compared to LGE, and similar transmurality. Subjective analysis with 2-blinded expert readers revealed agreement between ΔS/So and LGE of 73.4 %, with false positive detection of 16.7 % and false negative detection of 15.2 %. CONCLUSIONS: Gadolinium free 2-point bSSFP identified tissue that enhances at LGE with strong association to GPC. Our results suggest that with further development, MT-weighted CMR could be used similar to LGE for diagnostic imaging.


Asunto(s)
Cardiomiopatías/diagnóstico , Medios de Contraste , Gadolinio DTPA , Imagen por Resonancia Cinemagnética/métodos , Miocardio/patología , Remodelación Ventricular , Adulto , Anciano , Algoritmos , Cardiomiopatías/patología , Cardiomiopatías/fisiopatología , Estudios de Casos y Controles , Reacciones Falso Negativas , Reacciones Falso Positivas , Femenino , Fibrosis , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Volumen Sistólico
14.
J Cardiovasc Magn Reson ; 17: 75, 2015 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-26310667

RESUMEN

BACKGROUND: Obesity is a risk factor for cardiovascular disease. There is evidence of impaired left ventricular (LV) function associated with obesity, which may relate to cardiovascular mortality, but some studies have reported no dysfunction. Ventricular function data are generally acquired under resting conditions, which could mask subtle differences and potentially contribute to these contradictory findings. Furthermore, abnormal ventricular mechanics (strains, strain rates, and torsion) may manifest prior to global changes in cardiac function (i.e., ejection fraction) and may therefore represent more sensitive markers of cardiovascular disease. This study evaluated LV mechanics under both resting and stress conditions with the hypothesis that the LV mechanical dysfunction associated with obesity is exacerbated with stress and manifested at earlier stages of disease compared to baseline. METHODS: C57BL/6J mice were randomized to a high-fat or control diet (60 %, 10 % kcal from fat, respectively) for varying time intervals (n = 7 - 10 subjects per group per time point, 100 total; 4 - 55 weeks on diet). LV mechanics were quantified under baseline (resting) and/or stress conditions (40 µg/kg/min continuous infusion of dobutamine) using cine displacement encoding with stimulated echoes (DENSE) with 7.4 ms temporal resolution on a 7 T Bruker ClinScan. Peak strain, systolic strain rates, and torsion were quantified. A linear mixed model was used with Benjamini-Hochberg adjustments for multiple comparisons. RESULTS: Reductions in LV peak longitudinal strain at baseline were first observed in the obese group after 42 weeks, with no differences in systolic strain rates or torsion. Conversely, reductions in longitudinal strain and circumferential and radial strain rates were seen under inotropic stress conditions after only 22 weeks on diet. Furthermore, stress cardiovascular magnetic resonance (CMR) evaluation revealed supranormal values of LV radial strain and torsion in the obese group early on diet, followed by later deficits. CONCLUSIONS: Differences in left ventricular mechanics in obese mice are exacerbated under stress conditions. Stress CMR demonstrated a broader array of mechanical dysfunction and revealed these differences at earlier time points. Thus, it may be important to evaluate cardiac function in the setting of obesity under stress conditions to fully elucidate the presence of ventricular dysfunction.


Asunto(s)
Cardiotónicos/administración & dosificación , Dieta Alta en Grasa , Dobutamina/administración & dosificación , Imagen por Resonancia Cinemagnética , Contracción Miocárdica/efectos de los fármacos , Obesidad/complicaciones , Estrés Fisiológico , Disfunción Ventricular Izquierda/diagnóstico , Función Ventricular Izquierda/efectos de los fármacos , Animales , Fenómenos Biomecánicos , Modelos Animales de Enfermedad , Infusiones Intravenosas , Modelos Lineales , Masculino , Ratones Endogámicos C57BL , Valor Predictivo de las Pruebas , Factores de Riesgo , Estrés Mecánico , Factores de Tiempo , Torsión Mecánica , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/fisiopatología
15.
J Cardiovasc Magn Reson ; 17: 93, 2015 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-26538111

RESUMEN

BACKGROUND: Displacement Encoding with Stimulated Echoes (DENSE) encodes displacement into the phase of the magnetic resonance signal. The encoding frequency (ke) maps the measured phase to tissue displacement while the strength of the encoding gradients affects image quality. 2D cine DENSE studies have used a ke of 0.10 cycles/mm, which is high enough to remove an artifact-generating echo from k-space, provide high sensitivity to tissue displacements, and dephase the blood pool. However, through-plane dephasing can remove the unwanted echo and dephase the blood pool without relying on high ke. Additionally, the high sensitivity comes with the costs of increased phase wrapping and intra-voxel dephasing. We hypothesized that ke below 0.10 cycles/mm can be used to improve image characteristics and provide accurate measures of cardiac mechanics. METHODS: Spiral cine DENSE images were obtained for 10 healthy subjects and 10 patients with a history of heart disease on a 3 T Siemens Trio. A mid-ventricular short-axis image was acquired with different ke: 0.02, 0.04, 0.06, 0.08, and 0.10 cycles/mm. Peak twist, circumferential strain, and radial strain were compared between acquisitions employing different ke using Bland-Altman analyses and coefficients of variation. The percentage of wrapped pixels in the phase images at end-systole was calculated for each ke. The dephasing of the blood signal and signal to noise ratio (SNR) were also calculated and compared. RESULTS: Negligible differences were seen in strains and twist for all ke between 0.04 and 0.10 cycles/mm. These differences were of the same magnitude as inter-test differences. Specifically, the acquisitions with 0.04 cycles/mm accurately quantified cardiac mechanics and had zero phase wrapping. Compared to 0.10 cycles/mm, the acquisitions with 0.04 cycles/mm had 9 % greater SNR and negligible differences in blood pool dephasing. CONCLUSIONS: For 2D cine DENSE with through-plane dephasing, the encoding frequency can be lowered to 0.04 cycles/mm without compromising the quantification of twist or strain. The amount of wrapping can be reduced with this lower value to greatly simplify the input to unwrapping algorithms. The strain and twist results from studies using different encoding frequencies can be directly compared.


Asunto(s)
Cardiopatías/diagnóstico , Imagen por Resonancia Cinemagnética/métodos , Contracción Miocárdica , Función Ventricular , Adolescente , Adulto , Algoritmos , Artefactos , Fenómenos Biomecánicos , Estudios de Casos y Controles , Femenino , Cardiopatías/patología , Cardiopatías/fisiopatología , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Relación Señal-Ruido , Estrés Mecánico , Adulto Joven
16.
J Cardiovasc Magn Reson ; 17(1): 5, 2015 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-25634468

RESUMEN

BACKGROUND: Displacement Encoding with Stimulated Echoes (DENSE) encodes displacement into the phase of the magnetic resonance signal. Due to the stimulated echo, the signal is inherently low and fades through the cardiac cycle. To compensate, a spiral acquisition has been used at 1.5T. This spiral sequence has not been validated at 3T, where the increased signal would be valuable, but field inhomogeneities may result in measurement errors. We hypothesized that spiral cine DENSE is valid at 3T and tested this hypothesis by measuring displacement errors at both 1.5T and 3T in vivo. METHODS: Two-dimensional spiral cine DENSE and tagged imaging of the left ventricle were performed on ten healthy subjects at 3T and six healthy subjects at 1.5T. Intersection points were identified on tagged images near end-systole. Displacements from the DENSE images were used to project those points back to their origins. The deviation from a perfect grid was used as a measure of accuracy and quantified as root-mean-squared error. This measure was compared between 3T and 1.5T with the Wilcoxon rank sum test. Inter-observer variability of strains and torsion quantified by DENSE and agreement between DENSE and harmonic phase (HARP) were assessed by Bland-Altman analyses. The signal to noise ratio (SNR) at each cardiac phase was compared between 3T and 1.5T with the Wilcoxon rank sum test. RESULTS: The displacement accuracy of spiral cine DENSE was not different between 3T and 1.5T (1.2 ± 0.3 mm and 1.2 ± 0.4 mm, respectively). Both values were lower than the DENSE pixel spacing of 2.8 mm. There were no substantial differences in inter-observer variability of DENSE or agreement of DENSE and HARP between 3T and 1.5T. Relative to 1.5T, the SNR at 3T was greater by a factor of 1.4 ± 0.3. CONCLUSIONS: The spiral cine DENSE acquisition that has been used at 1.5T to measure cardiac displacements can be applied at 3T with equivalent accuracy. The inter-observer variability and agreement of DENSE-derived peak strains and torsion with HARP is also comparable at both field strengths. Future studies with spiral cine DENSE may take advantage of the additional SNR at 3T.


Asunto(s)
Ventrículos Cardíacos/anatomía & histología , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Contracción Miocárdica , Voluntarios Sanos , Humanos
17.
J Cardiovasc Magn Reson ; 16: 94, 2014 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-25430079

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance using displacement encoding with stimulated echoes (DENSE) is capable of assessing advanced measures of cardiac mechanics such as strain and torsion. A potential hurdle to widespread clinical adoption of DENSE is the time required to manually segment the myocardium during post-processing of the images. To overcome this hurdle, we proposed a radical approach in which only three contours per image slice are required for post-processing (instead of the typical 30-40 contours per image slice). We hypothesized that peak left ventricular circumferential, longitudinal and radial strains and torsion could be accurately quantified using this simplified analysis. METHODS AND RESULTS: We tested our hypothesis on a large multi-institutional dataset consisting of 541 DENSE image slices from 135 mice and 234 DENSE image slices from 62 humans. We compared measures of cardiac mechanics derived from the simplified post-processing to those derived from original post-processing utilizing the full set of 30-40 manually-defined contours per image slice. Accuracy was assessed with Bland-Altman limits of agreement and summarized with a modified coefficient of variation. The simplified technique showed high accuracy with all coefficients of variation less than 10% in humans and 6% in mice. The accuracy of the simplified technique was also superior to two previously published semi-automated analysis techniques for DENSE post-processing. CONCLUSIONS: Accurate measures of cardiac mechanics can be derived from DENSE cardiac magnetic resonance in both humans and mice using a simplified technique to reduce post-processing time by approximately 94%. These findings demonstrate that quantifying cardiac mechanics from DENSE data is simple enough to be integrated into the clinical workflow.


Asunto(s)
Cardiopatías/diagnóstico , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Cinemagnética , Contracción Miocárdica , Función Ventricular Izquierda , Animales , Automatización , Fenómenos Biomecánicos , Modelos Animales de Enfermedad , Cardiopatías/fisiopatología , Humanos , Kentucky , Ratones , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Estrés Mecánico , Factores de Tiempo , Torsión Mecánica , Virginia , Flujo de Trabajo
18.
Radiol Cardiothorac Imaging ; 5(3): e220196, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37404792

RESUMEN

Purpose: To develop a three-dimensional (two dimensions + time) convolutional neural network trained with displacement encoding with stimulated echoes (DENSE) data for displacement and strain analysis of cine MRI. Materials and Methods: In this retrospective multicenter study, a deep learning model (StrainNet) was developed to predict intramyocardial displacement from contour motion. Patients with various heart diseases and healthy controls underwent cardiac MRI examinations with DENSE between August 2008 and January 2022. Network training inputs were a time series of myocardial contours from DENSE magnitude images, and ground truth data were DENSE displacement measurements. Model performance was evaluated using pixelwise end-point error (EPE). For testing, StrainNet was applied to contour motion from cine MRI. Global and segmental circumferential strain (Ecc) derived from commercial feature tracking (FT), StrainNet, and DENSE (reference) were compared using intraclass correlation coefficients (ICCs), Pearson correlations, Bland-Altman analyses, paired t tests, and linear mixed-effects models. Results: The study included 161 patients (110 men; mean age, 61 years ± 14 [SD]), 99 healthy adults (44 men; mean age, 35 years ± 15), and 45 healthy children and adolescents (21 males; mean age, 12 years ± 3). StrainNet showed good agreement with DENSE for intramyocardial displacement, with an average EPE of 0.75 mm ± 0.35. The ICCs between StrainNet and DENSE and FT and DENSE were 0.87 and 0.72, respectively, for global Ecc and 0.75 and 0.48, respectively, for segmental Ecc. Bland-Altman analysis showed that StrainNet had better agreement than FT with DENSE for global and segmental Ecc. Conclusion: StrainNet outperformed FT for global and segmental Ecc analysis of cine MRI.Keywords: Image Postprocessing, MR Imaging, Cardiac, Heart, Pediatrics, Technical Aspects, Technology Assessment, Strain, Deep Learning, DENSE Supplemental material is available for this article. © RSNA, 2023.

20.
Nat Biomed Eng ; 5(6): 546-554, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33558735

RESUMEN

Machine learning promises to assist physicians with predictions of mortality and of other future clinical events by learning complex patterns from historical data, such as longitudinal electronic health records. Here we show that a convolutional neural network trained on raw pixel data in 812,278 echocardiographic videos from 34,362 individuals provides superior predictions of one-year all-cause mortality. The model's predictions outperformed the widely used pooled cohort equations, the Seattle Heart Failure score (measured in an independent dataset of 2,404 patients with heart failure who underwent 3,384 echocardiograms), and a machine learning model involving 58 human-derived variables from echocardiograms and 100 clinical variables derived from electronic health records. We also show that cardiologists assisted by the model substantially improved the sensitivity of their predictions of one-year all-cause mortality by 13% while maintaining prediction specificity. Large unstructured datasets may enable deep learning to improve a wide range of clinical prediction models.


Asunto(s)
Aprendizaje Profundo , Ecocardiografía/estadística & datos numéricos , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/mortalidad , Interpretación de Imagen Asistida por Computador/estadística & datos numéricos , Anciano , Bases de Datos Factuales , Ecocardiografía/métodos , Registros Electrónicos de Salud/estadística & datos numéricos , Femenino , Insuficiencia Cardíaca/patología , Humanos , Masculino , Persona de Mediana Edad , Curva ROC , Estudios Retrospectivos , Análisis de Supervivencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA