Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Ther Hypothermia Temp Manag ; 9(1): 56-62, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29883298

RESUMEN

Targeted temperature management (TTM) is recommended postcardiac arrest. The cooling method with the highest safety and efficacy is unknown. The COOL-ARREST pilot trial aimed to evaluate the safety and efficacy of the most contemporary ZOLL Thermogard XP Intravascular Temperature Management (IVTM) system for providing mild TTM postcardiac arrest. This multicenter, prospective, single-arm, observational pilot trial enrolled patients at eight U.S. hospitals between July 28, 2014, and July 24, 2015. Adult (≥18 years old), out-of-hospital cardiac arrest subjects of presumed cardiac etiology who achieved return of spontaneous circulation (ROSC) were considered for inclusion. Patients were excluded if (1) awake or consistently following commands after ROSC, (2) significant prearrest neurological dysfunction, (3) terminal illness or advanced directives precluding aggressive care, and (4) severe hemodynamic instability or shock. Patient temperature was maintained at 33.0°C ± 0.3°C for a total of 24 hours followed by controlled rewarming (0.1-0.2°C/h). Logistic regressions were used to assess association of good functional outcome (modified Rankin Scale ≤3) measured at the time of hospital discharge with shockable rhythm (yes/no), age, gender, race/ethnicity, lay-rescuer cardiopulmonary resuscitation, time to basic life support (minutes), time to ROSC (minutes), lactate (mg/dL), and pH on admission. The ZOLL IVTM system was effective at inducing TTM (median time to target temperature from initiation, 89 minutes [interquartile range 42-155]). Adverse events most often included electrolyte abnormalities and dysrhythmias. Of patients surviving to hospital discharge, 16/20 patients had a good functional outcome. A total of 18 patients survived through 90-day follow-up, at which time 94% (17/18) of patients had good functional outcome. The COOL-ARREST pilot trial demonstrates high safety and efficacy of the ZOLL Thermogard XP IVTM system in the application of mild TTM postcardiac arrest. This observational trial also revealed noteworthy variability in the management of postcardiac arrest patients, particularly with the use of early withdrawal of life-sustaining therapy.


Asunto(s)
Hipotermia Inducida/métodos , Paro Cardíaco Extrahospitalario/terapia , Anciano , Temperatura Corporal , Reanimación Cardiopulmonar , Femenino , Estudios de Seguimiento , Humanos , Hipotermia Inducida/efectos adversos , Hipotermia Inducida/instrumentación , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Recalentamiento , Análisis de Supervivencia , Resultado del Tratamiento
2.
Circulation ; 109(1): 108-13, 2004 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-14662713

RESUMEN

BACKGROUND: The precise role of arterial barotrauma-mediated apoptosis in causing restenosis is unclear. The purpose of this study was to determine if a link exists between angioplasty-mediated medial smooth muscle cell apoptosis and subsequent neointimal hyperplasia. METHODS AND RESULTS: Bilateral iliac artery angioplasty was performed in 25 male New Zealand White rabbits. Simultaneous with balloon injury, each artery was treated locally with either the caspase inhibitor N-benzyloxycarbonyl-Val-Ala-Asp(Ome)-fluoromethylketone (ZVAD-fmk) or control. In the acute cohort that was survived to 4 hours (n=10, 7 high dose and 3 low dose), an apoptotic index was calculated using the terminal deoxynucleotidyl TUNEL method. In the intermediate cohort that was survived to 2 weeks (n=5), luminal reendothelialization was measured via CD-31 staining. In the chronic cohort that was survived to 4 weeks (n=10), neointimal area was measured. In the acute cohort, there was a 40% reduction in the apoptotic index with high-dose ZVAD-fmk (P=0.008) and a 33% reduction with low-dose ZVAD-fmk (P=0.08). At 2 weeks, there was no significant difference in the degree of luminal reendothelialization. However, at 4 weeks, there was a 33% (0.33+/-0.23 versus 0.22+/-0.20 mm2) (P<0.005) reduction in neointimal area in ZVAD-fmk-treated arteries. CONCLUSIONS: The local delivery of ZVAD-fmk during balloon injury inhibits smooth muscle cell apoptosis. This corresponds to a significant reduction in neointimal proliferation seen at 4 weeks without a significant change in the degree of reendothelialization at 2 weeks.


Asunto(s)
Angioplastia Coronaria con Balón/efectos adversos , Apoptosis/fisiología , Caspasas/fisiología , Reestenosis Coronaria/patología , Músculo Liso Vascular/patología , Clorometilcetonas de Aminoácidos/farmacología , Animales , Apoptosis/efectos de los fármacos , Inhibidores de Caspasas , Reestenosis Coronaria/enzimología , Reestenosis Coronaria/prevención & control , Hiperplasia , Masculino , Músculo Liso Vascular/efectos de los fármacos , Músculo Liso Vascular/lesiones , Conejos , Túnica Íntima/patología
3.
JACC Cardiovasc Interv ; 7(8): 857-67, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25147030

RESUMEN

OBJECTIVES: This study sought to determine the effect of radial access on outcomes in women undergoing percutaneous coronary intervention (PCI) using a registry-based randomized trial. BACKGROUND: Women are at increased risk of bleeding and vascular complications after PCI. The role of radial access in women is unclear. METHODS: Women undergoing cardiac catheterization or PCI were randomized to radial or femoral arterial access. Data from the CathPCI Registry and trial-specific data were merged into a final study database. The primary efficacy endpoint was Bleeding Academic Research Consortium type 2, 3, or 5 bleeding or vascular complications requiring intervention. The primary feasibility endpoint was access site crossover. The primary analysis cohort was the subgroup undergoing PCI; sensitivity analyses were conducted in the total randomized population. RESULTS: The trial was stopped early for a lower than expected event rate. A total of 1,787 women (691 undergoing PCI) were randomized at 60 sites. There was no significant difference in the primary efficacy endpoint between radial or femoral access among women undergoing PCI (radial 1.2% vs. 2.9% femoral, odds ratio [OR]: 0.39; 95% confidence interval [CI]: 0.12 to 1.27); among women undergoing cardiac catheterization or PCI, radial access significantly reduced bleeding and vascular complications (0.6% vs. 1.7%; OR: 0.32; 95% CI: 0.12 to 0.90). Access site crossover was significantly higher among women assigned to radial access (PCI cohort: 6.1% vs. 1.7%; OR: 3.65; 95% CI: 1.45 to 9.17); total randomized cohort: (6.7% vs. 1.9%; OR: 3.70; 95% CI: 2.14 to 6.40). More women preferred radial access. CONCLUSIONS: In this pragmatic trial, which was terminated early, the radial approach did not significantly reduce bleeding or vascular complications in women undergoing PCI. Access site crossover occurred more often in women assigned to radial access. (SAFE-PCI for Women; NCT01406236).


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Arteria Femoral , Intervención Coronaria Percutánea/métodos , Arteria Radial , Anciano , Canadá , Enfermedad de la Arteria Coronaria/diagnóstico , Terminación Anticipada de los Ensayos Clínicos , Femenino , Hemorragia/etiología , Hemorragia/prevención & control , Humanos , Modelos Lineales , Persona de Mediana Edad , Oportunidad Relativa , Prioridad del Paciente , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Sistema de Registros , Factores de Riesgo , Factores Sexuales , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
4.
Echocardiography ; 24(2): 159-61, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17313547

RESUMEN

Percutaneous delivery of left atrial appendage (LAA) occluding devices represents a novel approach for stroke prevention in patients with atrial fibrillation. Transesophageal echocardiography (TEE) has a pivotal role throughout these procedures, facilitating device size selection and ensuring optimal deployment of the device. We report a case of an LAA occluding device implantation in which apparent proper positioning on fluoroscopy was determined by TEE to be malpositioning with a nonocclusive, perpendicular orientation to the plane of the LAA ostium. This problem appeared to be related to a complex, multilobed LAA anatomy and was readily resolved by repositioning of the device under TEE guidance.


Asunto(s)
Apéndice Atrial/anatomía & histología , Apéndice Atrial/diagnóstico por imagen , Cateterismo Cardíaco , Ecocardiografía Transesofágica , Prótesis e Implantes , Fibrilación Atrial/complicaciones , Fibrilación Atrial/terapia , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA