Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 209
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Radiol ; 31(10): 7614-7625, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33855588

RESUMEN

OBJECTIVES: Hepatocellular carcinoma (HCC) can be diagnosed non-invasively with contrast-enhanced ultrasound (CEUS) in cirrhosis if the characteristic pattern of arterial phase hyperenhancement followed by hypoenhancement is present. Recent studies suggest that diagnosis based on this "hyper-hypo" pattern needs further refinement. This study compares the diagnostic accuracies of standardized CEUS for HCC according to the current guideline definition and following the newly developed CEUS algorithms (CEUS LI-RADS®, ESCULAP) in a prospective multicenter real-life setting. METHODS: Cirrhotic patients with liver lesions on B-mode ultrasound were recruited prospectively from 04/2018 to 04/2019, and clinical and imaging data were collected. The CEUS standard included an additional examination point after 4-6 min in case of no washout after 3 min. The diagnostic accuracies of CEUS following the guidelines ("hyper-hypo" pattern), based on the examiner's subjective interpretation ("CEUS subjective"), and based on the CEUS algorithms ESCULAP and CEUS LI-RADS® were compared. RESULTS: In total, 470 cirrhotic patients were recruited in 43 centers. The final diagnosis was HCC in 378 cases (80.4%) according to the reference standard (histology 77.4%, MRI 16.4%, CT 6.2%). The "hyper-hypo" pattern yielded 74.3% sensitivity and 63% specificity. "CEUS subjective" showed a higher diagnostic accuracy (sensitivity, 91.5%; specificity, 67.4%; positive predictive value, 92%; negative predictive value, 66%). Sensitivity was higher for ESCULAP (95%) and "CEUS subjective" (91.5%) versus CEUS LI-RADS® (65.2%; p < 0.001). Specificity was highest for CEUS LI-RADS® (78.6%; p < 0.001). CONCLUSIONS: CEUS has an excellent diagnostic accuracy for the non-invasive diagnosis of HCC in cirrhosis. CEUS algorithms may be a helpful refinement of the "hyper-hypo" pattern defined by current HCC guidelines. KEY POINTS: • Contrast-enhanced ultrasound (CEUS) has a high diagnostic accuracy for the non-invasive diagnosis of hepatocellular carcinoma (HCC) in cirrhosis. • The CEUS algorithm ESCULAP (Erlanger Synopsis for Contrast-enhanced Ultrasound for Liver lesion Assessment in Patients at risk) showed the highest sensitivity, whereas the CEUS LI-RADS® (Contrast-Enhanced UltraSound Liver Imaging Reporting and Data System) algorithm yielded the highest specificity. • A standardized CEUS examination procedure with an additional examination point in the late phase, after 4-6 min in lesions with no washout after 3 min, is vital.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Algoritmos , Carcinoma Hepatocelular/complicaciones , Carcinoma Hepatocelular/diagnóstico por imagen , Medios de Contraste , Humanos , Cirrosis Hepática/complicaciones , Cirrosis Hepática/diagnóstico por imagen , Neoplasias Hepáticas/complicaciones , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética , Estudios Prospectivos , Estudios Retrospectivos , Ultrasonografía
2.
Knee Surg Sports Traumatol Arthrosc ; 26(7): 2080-2087, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29147741

RESUMEN

PURPOSE: Rupture of the Achilles tendon results in inferior scar tissue formation. Elastography allows a feasible in vivo investigation of biomechanical properties of the Achilles tendon. The purpose of this study is to investigate the biomechanical properties of healed Achilles tendons in the long term. MATERIALS AND METHODS: Patients who suffered from Achilles tendon rupture were recruited for an elastographic evaluation. Unilateral Achilles tendon ruptures were included and scanned in the mid-substance and calcaneal insertion at least 2 years after rupture using shear wave elastography. Results were compared to patients' contralateral non-injured Achilles tendons and additionally to a healthy population. Descriptive statistics, reliability analysis, and correlation analysis with clinical scores were performed. RESULTS: Forty-one patients were included in the study with a mean follow-up-time of 74 ± 30; [26-138] months after rupture. Significant differences were identified in shear wave elastography in the mid-substance of healed tendons (shear wave velocity 1.2 ±1.5 m/s) compared to both control groups [2.5 ±1.5 m/s (p < 0.01) and 2.8 ±1.6 m/s (p < 0.0001) contralateral and healthy population, respectively]. There was no correlation between the measurements and the clinical outcome. CONCLUSIONS: This study shows that the healed Achilles tendon after rupture has inferior elastic properties even after a long-term healing phase. Differences in elastic properties after rupture mainly originate from the mid-substance of the Achilles tendon, in which most of the ruptures occur. Elastographic results do not correspond with subjective perception. Clinically, sonoelastographical measurements of biomechanical properties can be useful to provide objective insights in tendon recovery.


Asunto(s)
Tendón Calcáneo/diagnóstico por imagen , Cicatriz/diagnóstico por imagen , Elasticidad , Traumatismos de los Tendones/diagnóstico por imagen , Tendón Calcáneo/fisiopatología , Tendón Calcáneo/cirugía , Adulto , Anciano , Fenómenos Biomecánicos , Cicatriz/fisiopatología , Elasticidad/fisiología , Diagnóstico por Imagen de Elasticidad/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Rotura , Traumatismos de los Tendones/fisiopatología , Traumatismos de los Tendones/terapia , Cicatrización de Heridas/fisiología
3.
Radiologe ; 58(6): 538-544, 2018 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-29797043

RESUMEN

CLINICAL/METHODICAL ISSUE: Contrast-enhanced ultrasound (CEUS) is becoming increasingly important for the detection and characterization of malignant liver lesions and allows percutaneous treatment when surgery is not possible. Contrast-enhanced ultrasound image fusion with computed tomography (CT) and magnetic resonance imaging (MRI) opens up further options for the targeted investigation of a modified tumor treatment. METHODICAL INNOVATIONS: Ultrasound image fusion offers the potential for real-time imaging and can be combined with other cross-sectional imaging techniques as well as CEUS. PERFORMANCE: With the implementation of ultrasound contrast agents and image fusion, ultrasound has been improved in the detection and characterization of liver lesions in comparison to other cross-sectional imaging techniques. In addition, this method can also be used for intervention procedures. The success rate of fusion-guided biopsies or CEUS-guided tumor ablation lies between 80 and 100% in the literature. ACHIEVEMENTS: Ultrasound-guided image fusion using CT or MRI data, in combination with CEUS, can facilitate diagnosis and therapy follow-up after liver interventions. PRACTICAL RECOMMENDATIONS: In addition to the primary applications of image fusion in the diagnosis and treatment of liver lesions, further useful indications can be integrated into daily work. These include, for example, intraoperative and vascular applications as well applications in other organ systems.


Asunto(s)
Medios de Contraste , Hígado/diagnóstico por imagen , Ultrasonografía , Humanos , Neoplasias Hepáticas , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X
4.
Ultraschall Med ; 37(3): 277-82, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25741669

RESUMEN

PURPOSE: A. fumigatus infections represent a major threat for patients with a suppressed immune system. Early diagnosis is of importance for a favorable outcome but appears to be difficult due to limited diagnostic procedures. Here we investigated the sensitivity of high-resolution ultrasound (HRU) for the detection of A. fumigatus infection in the liver. MATERIALS AND METHODS: BALB/c mice were intravenously infected with A. fumigatus and monitored by HRU, Doppler sonography (CCDS), contrast-enhanced ultrasound (CEUS), and real-time strain color-coded elastography (CCE) using a multi-frequency probe (6 - 15 MHz). Contrast media bolus injection of sulfur-hexafluoride micro-bubbles was applied and digital cine-loops from the arterial phase, as well as the portal venous phase up to the late phase of the whole liver were analyzed. All data were correlated to the histopathological findings. RESULTS: Using HRU and CEUS, a sonic shadow was detected in all infected animals. All Aspergillus-infected nodes from 3 - 6 mm in the liver showed a shadow with rim enhancement and no intranodal enhancement when using CEUS. A. fumigatus infection was confirmed by CFU assessment and histopathological analysis. Granulomas were not associated with shadowing on B-mode. In contrast, granulomas with a diameter above 5 mm and a higher stiffness in CCE generated particularly an arterial rim enhancement and portal venous washout without contrast media uptake in the late phase. In addition, CEUS was able to define dynamic capillary microvascularization of infected liver areas. CONCLUSION: Liver lesions associated with A. fumigatus infection can be detected in mice when combined with CEUS and CCE in vivo.


Asunto(s)
Aspergilosis/diagnóstico por imagen , Aspergillus fumigatus , Medios de Contraste , Gases , Aumento de la Imagen , Hepatopatías/diagnóstico por imagen , Animales , Aspergilosis/patología , Diagnóstico por Imagen de Elasticidad , Hígado/diagnóstico por imagen , Hígado/patología , Hepatopatías/patología , Ratones , Valores de Referencia
5.
Ultraschall Med ; 37(3): 290-6, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27112624

RESUMEN

PURPOSE: Aim of the present study was to investigate the sensitivity of high resolution ultrasound (HRU), standard contrast-enhanced ultrasound (CEUS) and CEUS using a novel vascular endothelial growth factor receptor 2 (VEGFR2)-targeted contrast agent for the detection of hepatic metastases in a mouse model of colorectal cancer using clinical standard technology. MATERIALS AND METHODS: The human colon cancer cell line HT29, transfected with luciferase cDNA for in vivo bioluminescence monitoring, was injected intrasplenically into CB17.SCID mice. Mice were monitored weekly by bioluminescence and after 2 and 4.5 weeks by HRU and CEUS. Contrast media (untargeted BR1, targeted BR55) was applied and digital cine loops from the arterial phase (15 - 45 sec), portal venous phase (50 - 120 s) and late phases (3 - 5 min, 1hour) of the whole liver were analyzed. Data were correlated with postmortem histopathology. RESULTS: Without contrast enhancement, lesions > 4 mm were reliably detected. After use of untargeted CEUS, lesions > 2 mm were reliably detected and enhanced rim vascularization and late-phase wash-out was shown. With BR55, lesions > 0.8 mm were reliably detected with excellent documentation of vascularization. A persistent contrast enhancement was seen > 30 min after injection. Contrast-enhancement patterns with BR55 significantly correlated with CD31 (R2 = 0.74) and VEGFR2-immunohistochemistry (R2 = 0.66). CONCLUSION: Detection of metastases by HRU and CEUS was earlier and more accurate than monitoring via bioluminescence. In vivo monitoring of hepatic micrometastases can thus be performed without prior modification of cancer cells using standard technology.


Asunto(s)
Neoplasias del Colon/diagnóstico por imagen , Medios de Contraste , Aumento de la Imagen , Lipopéptidos/administración & dosificación , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Hígado/diagnóstico por imagen , Imagen Molecular , Ultrasonografía , Receptor 2 de Factores de Crecimiento Endotelial Vascular , Animales , Femenino , Células HT29 , Humanos , Mediciones Luminiscentes , Ratones , Ratones Endogámicos , Microburbujas , Trasplante de Neoplasias
6.
Ultraschall Med ; 36(2): 168-73, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25607631

RESUMEN

PURPOSE: The main goal of cerebral endovascular aneurysm therapy is the complete occlusion of the aneurysm. Along with the development of new aneurysm treatment devices, repeated controls are necessary. We examined whether contrast-enhanced ultrasound can help to monitor aneurysms after endovascular treatment. MATERIALS AND METHODS: We prospectively examined 12 patients after coiling (7 patients) or flow diverter (FD) implantation (5 patients). These patients were examined with transcranial contrast-enhanced ultrasound using a matrix probe (1 - 5 MHz). Doppler sonography, Power Doppler, contrast harmonic imaging (CHI) and Power Doppler sonography (CPD) were included in the examination. Digital subtraction angiography with 3 D reconstructions served as the gold standard. Two radiologists decided in consensus about the degree of aneurysm occlusion separately in CEUS and digital subtraction angiography using a 4-point grading scheme. RESULTS: The degree of occlusion of the 12 aneurysms comparing the two imaging modalities was identical in 10 cases. In two cases CHI and CPD showed a small aneurysm remnant after coiling in the center of the coil pack while in digital subtraction angiography the aneurysms seemed completely occluded. CONCLUSION: The investigation indicates that contrast-enhanced ultrasound is a supportive, noninvasive method for post-interventional controls of intracranial aneurysms due to its ability to display not only macro- but also microvascularization.


Asunto(s)
Medios de Contraste , Embolización Terapéutica/instrumentación , Embolización Terapéutica/métodos , Aumento de la Imagen/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Ultrasonografía Doppler Transcraneal/métodos , Adulto , Angiografía de Substracción Digital , Femenino , Estudios de Seguimiento , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Hemorragia Subaracnoidea/diagnóstico por imagen , Hemorragia Subaracnoidea/terapia , Resultado del Tratamiento , Ultrasonografía Doppler en Color/métodos
7.
Radiologe ; 55(11): 937-48, 2015 Nov.
Artículo en Alemán | MEDLINE | ID: mdl-26464374

RESUMEN

CLINICAL/METHODICAL ISSUE: For diagnostic and interventional procedures ultrasound (US) image fusion can be used as a complementary imaging technique. METHODICAL INNOVATIONS: Image fusion has the advantage of real time imaging and can be combined with other cross-sectional imaging techniques. PERFORMANCE: With the introduction of US contrast agents sonography and image fusion have gained more importance in the detection and characterization of liver lesions. ACHIEVEMENTS: Fusion of US images with computed tomography (CT) or magnetic resonance imaging (MRI) facilitates the diagnostics and postinterventional therapy control. PRACTICAL RECOMMENDATIONS: In addition to the primary application of image fusion in the diagnosis and treatment of liver lesions, there are more useful indications for contrast-enhanced US (CEUS) in routine clinical diagnostic procedures, such as intraoperative US (IOUS), vascular imaging and diagnostics of other organs, such as the kidneys and prostate gland.


Asunto(s)
Medios de Contraste , Interpretación de Imagen Asistida por Computador/métodos , Imagen Multimodal/tendencias , Técnica de Sustracción/tendencias , Ultrasonografía/tendencias , Humanos , Aumento de la Imagen/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
Eur Radiol ; 24(10): 2449-57, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24965507

RESUMEN

OBJECTIVES: To assess the diagnostic accuracy of dual-energy computed tomography (DECT) for detection of endoleaks and aneurysm sac calcifications after endovascular aneurysm repair (EVAR) using hard plaque imaging algorithms. MATERIALS AND METHODS: One hundred five patients received 108 triple-phase contrast-enhanced CT (non-contrast, arterial and delayed phase) after EVAR. The delayed phase was acquired in dual-energy and post-processed using the standard (HPI-S) and a modified (HPI-M) hard plaque imaging algorithm. The reference standard was determined using the triple-phase CT and contrast-enhanced ultrasound. All images were analysed separately for the presence of endoleaks and calcifications by two independent readers; sensitivity, specificity and interobserver agreement were calculated. RESULTS: Endoleaks and calcifications were present in 25.9 % (28/108) and 20.4 % (22/108) of images. The HPI-S images had a sensitivity/specificity of 54 %/100 % (reader 1) and 57 %/99 % (reader 2), the HPI-M images of 93 %/92 % (reader 1) and 96 %/92 % (reader 2) for detection of endoleaks. For detection of calcifications HPI-S had a sensitivity/specificity of 91 %/99 % (reader 1) and 95 %/97 % (reader 2), the HPI-M images of 91 %/99 % (reader 1) and 91 %/99 % (reader 2), respectively. CONCLUSION: Using HPI-M, DECT enables an accurate diagnosis of endoleaks after EVAR and allows distinguishing between endoleaks and calcifications with high diagnostic accuracy. KEY POINTS: • Dual-energy computed tomography allows the diagnosis of aortic pathologies after EVAR. • Hard plaque imaging algorithms can distinguish between endoleaks and aneurysm sac calcifications. • The modified hard plaque imaging algorithm detects endoleaks with high diagnostic accuracy.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Calcinosis/complicaciones , Endofuga/diagnóstico por imagen , Procedimientos Endovasculares/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/cirugía , Calcinosis/diagnóstico por imagen , Endofuga/etiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Curva ROC , Reproducibilidad de los Resultados
9.
Z Gastroenterol ; 52(11): 1257-62, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25390212

RESUMEN

Abscesses and circumscribed collections of fluid are frequently found as complications of infectious diseases or surgery. Drainage is often indicated. We have established a new, economic, easy-to-make model to learn and improve competence in installing ultrasound-guided drainage. Up to fifteen water balloons (size 30 - 50 mm) were placed in a plastic box which then was filled with instant custard powder mixed with water. Spiral computed tomography (CT) of this box was performed. Experienced (n = 8) and inexperienced examiners (n = 8) drained the balloons via a direct puncture technique using either ultrasound-guidance alone or volume navigation with image fusion (ultrasound and CT) with needle tracking. Trainees filled out a questionnaire (before and after training) asking for information on their experience in ultrasound, in installing drainages and evaluating the new model. The time needed for installing the drainage was measured. None of the participants had ever attended a course on drainage installation. Only a few of the experienced examiners (n = 3) would autonomously install a drainage into a fluid collection with a size exceeding 4 cm before training. After training all participants felt more confident in ultrasound and in installing drainages into abscesses or other fluid collections. Most of the participants rated additional volume navigation with image fusion as a helpful tool. Ultrasound-guided drainage of abscesses can be trained easily with this new and economic model. Students and physicians can improve their skills and gain confidence in performing ultrasound-guided interventions.


Asunto(s)
Drenaje/instrumentación , Modelos Anatómicos , Modelos Educacionales , Fantasmas de Imagen , Cirugía Asistida por Computador/educación , Cirugía Asistida por Computador/instrumentación , Ultrasonografía Intervencional/instrumentación , Competencia Clínica , Análisis Costo-Beneficio , Drenaje/economía , Evaluación Educacional , Diseño de Equipo , Análisis de Falla de Equipo , Alemania , Humanos , Cirugía Asistida por Computador/economía , Ultrasonografía Intervencional/economía , Ultrasonografía Intervencional/métodos
10.
Clin Hemorheol Microcirc ; 86(1-2): 133-142, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37742633

RESUMEN

AIM: First assessment of flow changes in the jugular veins using high resolution ultrasound vector flow. MATERIAL UND METHODS: 15 patients (8 males, 7 females) with an age range of 35 to 82 years (mean age 58.53±12.26 years) were examined by an experienced examiner using high power ultrasound equipment (Resona R9, Mindray) with probe technology (Mindray L9-3U Linear Array transducer, 2.5 to 9.0 MHz). This group was compared with five healthy subjects (mean age 35.4±13.79 years) as a reference. To assess flow changes, the color-coded duplex sonography and the novel vector flow technique were used. The evaluation was performed of vector morphology changes, turbulence, and wall resistance measurements. RESULTS: There were changes after acute and chronic thrombosis in 9 cases, and venous compression in 7 cases. Turbulence was measurable from 0.01 % to 64.44 %, the average turbulence was 19.73±22.06 %. Wall resistance measurement showed values from 0.01 Pa to 3.14 Pa, depending on the age of the thrombosis or compression. The reference veins showed turbulence of 0.94±1.5 % and a mean wall resistance of 0.05±0.05 Pa. There are statistically significant differences between normal and thrombotic or compressed veins in terms of maximum wall stress (p = 0.006) and mean degree of turbulence (p = 0.012), while the difference in mean wall stress is not statistically significant (p = 0.058). CONCLUSION: Despite still existing technical limitations, the combination of V-flow and wall stress measurements in jugular vein changes suggests a high diagnostic potential.


Asunto(s)
Venas Yugulares , Trombosis , Masculino , Femenino , Humanos , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Adulto Joven , Venas Yugulares/diagnóstico por imagen , Venas , Trombosis/diagnóstico por imagen , Ultrasonografía Doppler Dúplex
11.
Clin Hemorheol Microcirc ; 86(1-2): 99-108, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37638423

RESUMEN

BACKGROUND: Lipedema is a chronic disease marked by symmetric enlargement of painful nodular and fibrotic adipose tissue, predominantly affecting the limbs. Since there is no specific test or biomarker for this condition, years often pass before the diagnosis of lipedema is established for the first time, thereby causing psychosocial distress, including depression, eating disorders, and social isolation. Over the last few years several advanced Doppler-based technologies have been developed to visualize slow flow blood vessels and superficial microvascular architecture undetectable by traditional color Doppler flow imaging (CDFI). OBJECTIVE: The aim of this study was to evaluate the superficial microvascular anatomy in lipedema patients compared to healthy controls and investigate the clinical significance of the Ultra Micro Angiography (UMA) technology in the diagnosis of lipedema. This new technique may contribute to reduce the diagnostic delay and, eventually, establish and guide treatment strategies toward a better therapeutic outcome in lipedema patients. METHODS: 25 patients with lipedema and ten healthy controls with no history of lipedema were included in this study. All ultrasound examinations were performed on a novel high-performance ultrasound system (Resona R9/Mindray) using CDFI and the UMA technique. RESULTS: In all of the patients, Ultra Micro Angiography achieved the excellent visualization of microvascular structures, revealing that most lipedema patients showed grade 3 (n = 13) or grade 2 (n = 8) flow. UMA was superior to CDFI for depicting the microvascular structures. CONCLUSIONS: Here we show that UMA imaging characterizes the subcutaneous microvasculature with an unprecedented accuracy. The method has the advantage of being sensitive to small, slow-flowing vessels. This allows for the assessment of the course of vessels and vascular pathologies in great detail. Thus, UMA as a non-invasive diagnostic method can improve diagnostic accuracy in lipedema.


Asunto(s)
Lipedema , Humanos , Lipedema/diagnóstico por imagen , Lipedema/patología , Diagnóstico Tardío/efectos adversos , Ultrasonografía/métodos , Dolor , Fibrosis
12.
Ultraschall Med ; 34(6): 550-8, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24127394

RESUMEN

PURPOSE: Tissue defects are a common problem in trauma surgery and oncology. Flap transplantation is often the only therapy to cover such defects. Several monitoring systems are currently available but none has made it to the clinical routine. The aim of this study was to assess perfusion disturbances of local and free flaps using contrast-enhanced ultrasound (CEUS). MATERIALS AND METHODS: 112 patients were examined during the first 72 hours after operation. CEUS was performed by one experienced examiner with a linear transducer (6 - 9 MHz, LOGIQE9/GE) after a bolus injection of 2.4 ml sulfohexa-fluoride microbubbles (SonoVue®, Bracco, Italy). Retrospective vascular perfusion was quantified by evaluating the stored DICOM cine loops using the perfusion software QONTRAST® (Bracco, Italy). Over a total penetration depth of 3 cm, every centimeter was analyzed separately. 27 complications were observed. Complete flap loss was only seen in 4 cases, while 23 flaps had to undergo minor revision and survived. RESULTS: Regarding the complete flap size, quantitative analysis showed significantly higher perfusion values in patients without complications compared to patients with complications: PEAK 16.5 vs. 10.0 (p = 0.001), TTP 32.6 vs. 22.2 (p = 0.001), RBV: 738.8 vs. 246.2 (p < 0.001), RBF 17.5 vs. 10.1 (p < 0.001) and MTT 43.1 vs. 29.5 (p = 0.001). Analysis of the correlation of the different flap types, age, sex and etiology of the tissue defect to the complication rate showed no statistical correlation. CONCLUSION: CEUS was capable of detecting vascular disturbances after flap transplantation. TTP, RBV and MTT seem to be the most accurately parameters and are not susceptible to malfunction during measurement.


Asunto(s)
Medios de Contraste , Colgajos Tisulares Libres/irrigación sanguínea , Colgajos Tisulares Libres/cirugía , Aumento de la Imagen , Fosfolípidos , Complicaciones Posoperatorias/diagnóstico por imagen , Hexafluoruro de Azufre , Colgajos Quirúrgicos/irrigación sanguínea , Colgajos Quirúrgicos/cirugía , Velocidad del Flujo Sanguíneo/fisiología , Femenino , Supervivencia de Injerto/fisiología , Humanos , Interpretación de Imagen Asistida por Computador , Isquemia/diagnóstico por imagen , Isquemia/cirugía , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/cirugía , Flujo Sanguíneo Regional/fisiología , Reoperación , Sensibilidad y Especificidad , Programas Informáticos , Ultrasonografía
13.
Ultraschall Med ; 34(3): 272-9, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23709242

RESUMEN

BACKGROUND: Extensive wound defects frequently have to be covered by free flap transplantation. A monitoring device for measuring capillary level perfusion of bone is currently not available. OBJECTIVE: The aim of the study was to detect complications after osteocutaneous flap transplantation using contrast-enhanced ultrasound (CEUS). Additionally quantitative analysis was performed by special perfusion software (QONTRAST®; Bracco, Italy). METHODS: 22 patients were examined after osteocutaneous flap transplantation during the first 72 h after operation. CEUS was performed with a linear transducer (6-9 MHz, LOGIQ E9/GE) after bolus injections of 2.4 ml ultrasound contrast agent (SonoVue®; Bracco, Italy). The osseous perfusion and soft tissue perfusion were analyzed separately and quantitative perfusion analysis was performed. Five patients had to undergo reoperation due to compromised flap microvascularization. RESULTS: In all 5 complications reduced osseous and soft tissue perfusion was seen using CEUS. Additionally using the perfusion parameters TTP (time to PEAK), RBV (regional blood volume), RBF (regional blood flow) und MTT (mean transit time), significantly lower soft tissue and osseous perfusion was detected. CONCLUSION: CEUS seems to be capable of detecting vascular disturbances and of assessing microvascularization of the osseous component after osteocutaneous flap transplantation.


Asunto(s)
Trasplante Óseo/métodos , Huesos/irrigación sanguínea , Medios de Contraste , Colgajos Tisulares Libres/irrigación sanguínea , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Microcirculación/fisiología , Fosfolípidos , Complicaciones Posoperatorias/diagnóstico por imagen , Infecciones de los Tejidos Blandos/diagnóstico por imagen , Infecciones de los Tejidos Blandos/cirugía , Traumatismos de los Tejidos Blandos/diagnóstico por imagen , Traumatismos de los Tejidos Blandos/cirugía , Neoplasias de los Tejidos Blandos/diagnóstico por imagen , Neoplasias de los Tejidos Blandos/cirugía , Hexafluoruro de Azufre , Ultrasonografía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Capilares/diagnóstico por imagen , Capilares/patología , Femenino , Colgajos Tisulares Libres/cirugía , Humanos , Isquemia/diagnóstico por imagen , Isquemia/cirugía , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/cirugía , Reoperación , Programas Informáticos
14.
Ultraschall Med ; 34(6): 590-4, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24132649

RESUMEN

PURPOSE: To evaluate the reliability of ultrasound elastography for delineating thermal ablation defects post-radiofrequency ablation (RFA) by comparing lesion dimensions determined by real-time elastography (RTE) with the findings of contrast-enhanced ultrasound (CEUS). MATERIALS AND METHODS: A total of 21 malignant liver tumors were percutaneously ablated using RFA. Color-coded elastography and CEUS were performed by one experienced examiner, using a 1 - 5 MHz multi-frequency convex transducer (LOGIQ E9, GE). Lesions were examined using CEUS and real-time elastography (RTE) to assess ablation defects. Measurements of lesions (long axis, short axis, and area) representing the same image plane used for elastography were taken during CEUS examination and compared to the measurements obtained from the elastograms. All measurements were performed by two independent observers. RESULTS: A statistically significant correlation in vivo between RTE and CEUS measurements with respect to the lesion's principal axis and area (r = 0.876 long axis, r = 0.842 short axis and r = 0.889 area) was found. Inter-rater reliability assessed with the concordance correlation coefficient was substantial for all measurements (ρc ≥ 0.96) Overall, elastography slightly underestimated the lesion size, as judged by the CEUS images. CONCLUSION: These results support that RTE could potentially be used for the routine assessment of thermal ablation therapies.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/cirugía , Ablación por Catéter , Medios de Contraste , Diagnóstico por Imagen de Elasticidad/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Fosfolípidos , Hexafluoruro de Azufre , Ultrasonografía/métodos , Anciano , Femenino , Humanos , Hígado/diagnóstico por imagen , Hígado/cirugía , Neoplasias Hepáticas/secundario , Masculino , Persona de Mediana Edad , Neoplasia Residual/diagnóstico por imagen , Variaciones Dependientes del Observador , Complicaciones Posoperatorias/diagnóstico por imagen , Estudios Prospectivos , Sensibilidad y Especificidad , Estadística como Asunto
15.
Radiologe ; 53(11): 962-73, 2013 Nov.
Artículo en Alemán | MEDLINE | ID: mdl-24177722

RESUMEN

CLINICAL/METHODICAL ISSUE: Optimization of ultrasound guided interventional procedures of the liver and kidneys using new imaging methods. STANDARD RADIOLOGICAL METHODS: Punctures, biopsies, drainage, intraoperative ultrasound, fusion, embolization in correlation with ultrasound and other imaging methods. METHODICAL INNOVATIONS: Real-time-sonography, contrast-enhanced ultrasound (CEUS) and fusion for planning, monitoring and postinterventional control. PERFORMANCE: The use of CEUS enables better detection, characterization and execution of interventional procedures. Fusion facilitates detection. ACHIEVEMENTS: The CEUS procedure is superior for detection and characterization of smaller lesions in comparison to the B scan. Fusion enables the performance of difficult interventional procedures. PRACTICAL RECOMMENDATIONS: The B scan is the standard imaging method but CEUS and fusion could be helpful for smaller lesions.


Asunto(s)
Enfermedades Renales/diagnóstico por imagen , Enfermedades Renales/terapia , Hepatopatías/diagnóstico por imagen , Hepatopatías/terapia , Cirugía Asistida por Computador/métodos , Ultrasonografía Intervencional/métodos , Humanos
16.
Clin Hemorheol Microcirc ; 84(2): 227-236, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37092219

RESUMEN

 Goal of the study was the assessment of AI-assisted diagnosis of solid thyroid foci with multimodal modern ultrasound imaging. 50 patients (26-81 years, 54.7±13.1 years) were included in the study. Multimodal ultrasound imaging by means of B-mode with linear probe (4-12 MHz) with option of automated documentation of findings by means of AI, with supplementary Ultra MicroAngiography (UMA) was used. Macrovascularisation was assessed by dynamic contrast ultrasonography (CEUS) with parametric evaluation and perfusion analysis, and microvascularization was assessed by combined strain and shear wave elastography on a novel high-performance ultrasound system (Resona R9/Mindray) by an experienced examiner with independent reading. The evaluation was performed according to TI-RADS III-V.The volume of the thyroid lobes on both sides averaged 39 ml±5 ml (27 to 69 ml). The 13 cases of histologically confirmed thyroid carcinomas (8 papillary, 2 medullary, 2 microfollicular, 1 anaplastic CA) with a mean size of 15 mm±6 mm (9-21 mm) were correctly evaluated by TI-RADS V on the basis of irregular shape, induration > 2.5 m/s or > 30kPA and striking wash-out kinetics. Tumor lymph nodes could only be correctly detected preoperatively in one case of medullary carcinoma according to the surgical findings, based on irregular vascularization with UMA in roundish shape with cortex > 4 mm, transverse diameter up to 11 mm. In 25 cases of inhomogeneous nodular goiter an evaluation with TI-RADS III was performed in 31 cases, in 4 cases with incomplete marginal contour, partial marginal vascularization with UMA and partial wash out with indurations up to 2.5 m/s 30 kPA an evaluation with TI-RADS IV and surgical excision for nodular goiter. In 12 cases regressive nodular changes without relevant malignancy criteria resulted in nodular goiter, with focal changes up to 1.5 cm in diameter, classified as requiring control with TI-RADS III. There were no relevant changes in findings in the controls after 6 months. From the AI tool, the 20/25 goiter nodes were assessed as TI-RADS III, 7/12 adenomas, 5 goiter nodes, and 5 adenomas as TI-RADS IV, 5/13 carcinomas as TI-RADS IV, and 8/13 carcinomas as TI-RADS V.Multimodal ultrasound diagnostics supported by AI has a high diagnostic potential for the evaluation of solid thyroid lesions and standardizes the reporting with digital representative image documentation. CEUS perfusion and modern elastography techniques allow targeted follow-up of TI-RADS III findings.


Asunto(s)
Carcinoma Neuroendocrino , Diagnóstico por Imagen de Elasticidad , Bocio Nodular , Neoplasias de la Tiroides , Nódulo Tiroideo , Humanos , Inteligencia Artificial , Diagnóstico por Imagen de Elasticidad/métodos , Imagen Multimodal , Perfusión , Estudios Retrospectivos , Sensibilidad y Especificidad , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/patología , Nódulo Tiroideo/patología , Ultrasonografía/métodos , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años
17.
Clin Hemorheol Microcirc ; 83(2): 181-193, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36776044

RESUMEN

Current ultrasound multifrequency probes allow both improved detail resolution and depth of penetration when examining the liver. Also, new developments in vascular diagnostics, elastography with fibrosis assessment, evaluation of possible steatosis, and parametric and time intensity curve (TIC) analysis of dynamic microvascularization of the liver with contrast-enhanced ultrasound sonography (CEUS) complement ultrasound-guided diagnostics. State-of-the-art high-resolution technology includes a high frame rate (HiFR) mode for CEUS, fast shear wave measurements with the sound touch quantify (STQ) mode, artifact-free flow detection using HR flow and glazing flow in combination with a special flow-adapted imaging (Ultra Micro Angiography, UMA) and additionally different assessments of possible fatty liver (UltraSound ATtenuation Imaging Technology, USAT). In 50 cases with focal liver lesions, a multimodal liver diagnosis was performed with a still new high-performance ultrasound system as part of the clarification of questions from the university liver consultation and tumor outpatient clinic.


Asunto(s)
Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/patología , Medios de Contraste , Ultrasonografía/métodos , Hígado/diagnóstico por imagen , Perfusión , Fibrosis
18.
J Physiol Pharmacol ; 74(2)2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37453095

RESUMEN

Building a precise alternative neurotoxicological test is of great importance to respond to societal and ethical requirements. In this study, a new developmental neurotoxicity test (DNT) was established with the human neural progenitor cell line. ReNcell CX cells were exposed to neurotoxic chemicals (aphidicolin, hydroxyurea, cytosine arabinoside, 5-fluorouracil, and ochratoxin A) or non-neurotoxic chemicals (sodium gluconate, sodium bicarbonate, penicillin G, and saccharin). Propidium iodide (PI) was used to evaluate cell viability. BrdU and Ki-76 were employed to determine cell proliferation. Based on the cell viability and proliferation, mathematical models were built by linear discriminant analysis. Furthermore, the neurotoxic-considered chemicals inhibited cell cycle progression at the protein level, supporting the biomolecular rationale for the predictive model. Overall, these results show that the new test method can be used to determine the potential developmental neurotoxicants or new drug candidates.


Asunto(s)
Células-Madre Neurales , Síndromes de Neurotoxicidad , Humanos , Antígeno Ki-67/metabolismo , Células-Madre Neurales/metabolismo , Síndromes de Neurotoxicidad/metabolismo , Línea Celular
19.
Acta Radiol ; 53(10): 1133-6, 2012 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-23091236

RESUMEN

BACKGROUND: Technological advances introduced hand-carried ultrasound (HCU) imagers in daily clinical workflow providing several benefits such as fast bedside availability and prompt diagnosis. PURPOSE: To evaluate the diagnostic yield of a latest generation HCU imager compared to contrast-enhanced multidetector computed tomography (MDCT) for the detection of pericardial effusion (PE) in cardiothoracic intensive care unit (ICU) patients. MATERIAL AND METHODS: Thirty-six patients from a cardiothoracic ICU were enrolled to this study irrespective of their underlying disease. All patients were examined with a new generation HCU for the presence of PE. Definite diagnosis of PE was based on findings of MDCT as standard of reference. Statistical analysis was performed using PASW 18. RESULTS: PE was identified in 20 patients by MDCT (prevalence 56%). The HCU examination was carried out technically successfully in all patients. Sensitivity, specificity, positive and negative predictive value of HCU for the diagnosis of PE were 75%, 88%, 88%, and 74%, respectively. CONCLUSION: HCU provides rapid, practical, reliable, and cost-effective diagnosis of PE in patients on cardiothoracic ICU.


Asunto(s)
Cuidados Críticos/métodos , Unidades de Cuidados Intensivos , Derrame Pericárdico/diagnóstico por imagen , Sistemas de Atención de Punto , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Diagnóstico Diferencial , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Intensificación de Imagen Radiográfica/métodos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X , Ultrasonografía , Adulto Joven
20.
Acta Radiol ; 53(5): 556-60, 2012 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-22661602

RESUMEN

BACKGROUND: Further development established hand-carried ultrasound (HCU) imagers in daily clinical workflow providing several advantages such as fast bedside availability and prompt diagnosis. PURPOSE: To evaluate the diagnostic yield of a latest generation HCU imager compared to chest radiography (CR) for the detection of pleural effusion (PE) in intensive care patients. MATERIAL AND METHODS: Forty-eight hemithoraces of 24 patients on surgical intensive care units were enrolled in this study. All hemithoraces were evaluated using both HCU and CR. Definite diagnosis of PE was achieved using a high-end ultrasound system as standard of reference. Statistical analysis was performed using 2 × 2 tables and a McNemar test. A P value of <0.05 was considered statistically significant. RESULTS: PE was present in 35 of 48 hemithoraces (73%). The HCU examination was carried out technically successfully in all hemithoraces. Sensitivity and specificity of HCU for the diagnosis of PE was 91% and 100%, respectively, whereas sensitivity and specificity of CR was 74% and 31%, respectively. The difference between HCU and CR was statistically significant with respect to specificity but not sensitivity (P = 0.008 and P = 0.11, respectively). CONCLUSION: Due to its ease of use and its high diagnostic yield HCU systems of the latest generation constitute a helpful technique for the primary assessment of PE.


Asunto(s)
Unidades de Cuidados Intensivos , Derrame Pleural/diagnóstico por imagen , Sistemas de Atención de Punto , Ultrasonografía/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiografía Torácica , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA