Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Neurourol Urodyn ; 37(1): 440-448, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29095516

RESUMEN

AIMS: The SUCCESS trial is a phase III study of the Vesair® balloon in the United States for female stress urinary incontinence (SUI). The purpose of this manuscript is to present the 3 month primary efficacy and tolerability outcome data. METHODS: The SUCCESS trial is a multi-center, prospective, single blind, randomized, sham-controlled study. Subjects were randomized on a 2.33:1 basis to either Vesair balloon placement or placebo. The primary efficacy endpoint was a composite of both a >50% reduction from baseline on 1 h provocative pad weight test and a ≥10-point improvement in symptoms on the Incontinence Quality of Life Survey (I-QOL) questionnaire assessed at the 3 month study visit. RESULTS: A total of 221 subjects were randomized, including 157 treatment arm subjects and 64 controls. The 3 month composite primary efficacy endpoint was achieved in 42.1% of treatment group subjects compared with 28.1% of controls on intention-to-treat analysis (p = 0.046). Treatment arm subjects were significantly more likely to report at least a 50% reduction in incontinence frequency on 7-day voiding diary (55.2% vs 32.3%, P = 0.002, ITT) and more commonly reported their incontinence was improved on Patient Global Impression of Improvement in Incontinence (PGI-I) at 3 months compared with controls (58.0% vs 37.7%, P = 0.007, ITT). No device- or procedure-related serious adverse events nor unanticipated adverse events were reported and no cases of urinary retention were observed. All adverse events fully resolved following balloon removal. CONCLUSIONS: In this phase three trial, the Vesair intravesical balloon achieved 3 month primary and secondary endpoints both objectively and subjectively.


Asunto(s)
Oclusión con Balón/métodos , Incontinencia Urinaria de Esfuerzo/terapia , Oclusión con Balón/efectos adversos , Diseño de Equipo , Femenino , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Calidad de Vida , Método Simple Ciego , Resultado del Tratamiento , Incontinencia Urinaria de Esfuerzo/psicología
2.
Female Pelvic Med Reconstr Surg ; 24(3): 222-231, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-28953076

RESUMEN

OBJECTIVES: The "Stress Incontinence Control, Efficacy and Safety Study" (SUCCESS) is a phase III study of the Vesair Balloon in women with stress urinary incontinence who had failed conservative therapy, and either failed surgery, were not candidates for surgery, or chose not to have surgery. The safety and efficacy of the balloon at 12 months is reported for those participants in the treatment arm who elected to continue with the SUCCESS trial beyond the primary end point at 3 months. METHODS: The SUCCESS trial is a multicenter, prospective, single-blinded, randomized, sham-controlled study. Participants were randomized on a 2.33:1 basis to either Vesair Balloon placement or placebo. The primary efficacy end point was a composite of both a greater than 50% reduction from baseline on 1-hour provocative pad weight test and an at least 10-point improvement in symptoms on the Incontinence Quality of Life questionnaire assessed at the 3-month study visit. Patients in the treatment arm who opted to continue in the trial were followed up prospectively up to 12 months. RESULTS: A total of 221 participants were randomized, including 157 in the treatment arm and 64 in the control arm. Sixty-seven participants in the treatment arm (42.7% of participants enrolled) were evaluated at 12 months, with 56.3% achieving the composite end point and 78.7% having greater than 50% reduction in pad weight from baseline in a per-protocol analysis. In an intent-to-treat analysis treating all participants who did not continue with the balloon as failures, 24% of the participants achieved the composite end point and 33.6% had a greater than 50% reduction in pad weight from baseline. Treatment-related adverse events in this group included dysuria (40.1%), gross hematuria (36.9%), and urinary tract infection (26.1%). CONCLUSIONS: In this phase III trial, symptom relief was maintained for those participants who continued therapy for 12 months. The balloon was found to be safe with no device- or procedure-related serious adverse events reported. Additional studies are warranted to determine which patient populations are more tolerant of the balloon and to assess the efficacy and safety of its longer-term use. Additional screening methods, including screening patients for balloon tolerability, are warranted to reduce participant withdrawals.


Asunto(s)
Incontinencia Urinaria de Esfuerzo/terapia , Adulto , Femenino , Estudios de Seguimiento , Humanos , Pañales para la Incontinencia/estadística & datos numéricos , Persona de Mediana Edad , Cooperación del Paciente/estadística & datos numéricos , Estudios Prospectivos , Calidad de Vida , Método Simple Ciego , Resultado del Tratamiento , Vejiga Urinaria/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA