Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 579
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 388(22): 2037-2048, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-36876756

RESUMEN

BACKGROUND: Data from a 5-year follow-up of outcomes after transcatheter edge-to-edge repair of severe mitral regurgitation, as compared with outcomes after maximal doses of guideline-directed medical therapy alone, in patients with heart failure are now available. METHODS: We randomly assigned patients with heart failure and moderate-to-severe or severe secondary mitral regurgitation who remained symptomatic despite the use of maximal doses of guideline-directed medical therapy to undergo transcatheter edge-to-edge repair plus receive medical therapy (device group) or to receive medical therapy alone (control group) at 78 sites in the United States and Canada. The primary effectiveness end point was all hospitalizations for heart failure through 2 years of follow-up. The annualized rate of all hospitalizations for heart failure, all-cause mortality, the risk of death or hospitalization for heart failure, and safety, among other outcomes, were assessed through 5 years. RESULTS: Of the 614 patients enrolled in the trial, 302 were assigned to the device group and 312 to the control group. The annualized rate of hospitalization for heart failure through 5 years was 33.1% per year in the device group and 57.2% per year in the control group (hazard ratio, 0.53; 95% confidence interval [CI], 0.41 to 0.68). All-cause mortality through 5 years was 57.3% in the device group and 67.2% in the control group (hazard ratio, 0.72; 95% CI, 0.58 to 0.89). Death or hospitalization for heart failure within 5 years occurred in 73.6% of the patients in the device group and in 91.5% of those in the control group (hazard ratio, 0.53; 95% CI, 0.44 to 0.64). Device-specific safety events within 5 years occurred in 4 of 293 treated patients (1.4%), with all the events occurring within 30 days after the procedure. CONCLUSIONS: Among patients with heart failure and moderate-to-severe or severe secondary mitral regurgitation who remained symptomatic despite guideline-directed medical therapy, transcatheter edge-to-edge repair of the mitral valve was safe and led to a lower rate of hospitalization for heart failure and lower all-cause mortality through 5 years of follow-up than medical therapy alone. (Funded by Abbott; COAPT ClinicalTrials.gov number, NCT01626079.).


Asunto(s)
Cateterismo Cardíaco , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Estudios de Seguimiento , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
2.
N Engl J Med ; 389(21): 1949-1960, 2023 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-37874020

RESUMEN

BACKGROUND: A previous analysis in this trial showed that among patients with severe, symptomatic aortic stenosis who were at low surgical risk, the rate of the composite end point of death, stroke, or rehospitalization at 1 year was significantly lower with transcatheter aortic-valve replacement (TAVR) than with surgical aortic-valve replacement. Longer-term outcomes are unknown. METHODS: We randomly assigned patients with severe, symptomatic aortic stenosis and low surgical risk to undergo either TAVR or surgery. The first primary end point was a composite of death, stroke, or rehospitalization related to the valve, the procedure, or heart failure. The second primary end point was a hierarchical composite that included death, disabling stroke, nondisabling stroke, and the number of rehospitalization days, analyzed with the use of a win ratio analysis. Clinical, echocardiographic, and health-status outcomes were assessed through 5 years. RESULTS: A total of 1000 patients underwent randomization: 503 patients were assigned to undergo TAVR, and 497 to undergo surgery. A component of the first primary end point occurred in 111 of 496 patients in the TAVR group and in 117 of 454 patients in the surgery group (Kaplan-Meier estimates, 22.8% in the TAVR group and 27.2% in the surgery group; difference, -4.3 percentage points; 95% confidence interval [CI], -9.9 to 1.3; P = 0.07). The win ratio for the second primary end point was 1.17 (95% CI, 0.90 to 1.51; P = 0.25). The Kaplan-Meier estimates for the components of the first primary end point were as follows: death, 10.0% in the TAVR group and 8.2% in the surgery group; stroke, 5.8% and 6.4%, respectively; and rehospitalization, 13.7% and 17.4%. The hemodynamic performance of the valve, assessed according to the mean (±SD) valve gradient, was 12.8±6.5 mm Hg in the TAVR group and 11.7±5.6 mm Hg in the surgery group. Bioprosthetic-valve failure occurred in 3.3% of the patients in the TAVR group and in 3.8% of those in the surgery group. CONCLUSIONS: Among low-risk patients with severe, symptomatic aortic stenosis who underwent TAVR or surgery, there was no significant between-group difference in the two primary composite outcomes. (Funded by Edwards Lifesciences; PARTNER 3 ClinicalTrials.gov number, NCT02675114.).


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Estudios de Seguimiento , Readmisión del Paciente , Insuficiencia Cardíaca/etiología
3.
Circulation ; 149(10): 734-743, 2024 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-37874908

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is common in patients undergoing transcatheter aortic valve replacement (TAVR) and is associated with increased risk of bleeding and stroke. While left atrial appendage occlusion (LAAO) is approved as an alternative to anticoagulants for stroke prevention in patients with AF, placement of these devices in patients with severe aortic stenosis, or when performed at the same time as TAVR, has not been extensively studied. METHODS: WATCH-TAVR (WATCHMAN for Patients with AF Undergoing TAVR) was a multicenter, randomized trial evaluating the safety and effectiveness of concomitant TAVR and LAAO with WATCHMAN in AF patients. Patients were randomized 1:1 to TAVR + LAAO or TAVR + medical therapy. WATCHMAN patients received anticoagulation for 45 days followed by dual antiplatelet therapy until 6 months. Anticoagulation was per treating physician preference for patients randomized to TAVR + medical therapy. The primary noninferiority end point was all-cause mortality, stroke, and major bleeding at 2 years between the 2 strategies. RESULTS: The study enrolled 349 patients (177 TAVR + LAAO and 172 TAVR + medical therapy) between December 2017 and November 2020 at 34 US centers. The mean age of patients was 81 years, and the mean scores for CHA2DS2-VASc and HAS-BLED (Hypertension, Abnormal renal/liver function, Stroke, Bleeding history or predisposition, Labile INR, Elderly, Drugs/alcohol concomitantly) were 4.9 and 3.0, respectively. At baseline, 85.4% of patients were taking anticoagulants and 71.3% patients were on antiplatelet therapy. The cohorts were well-balanced for baseline characteristics. The incremental LAAO procedure time was 38 minutes, and the median contrast volume used for combined procedures was 119 mL versus 70 mL with TAVR alone. At the 24-month follow-up, 82.5% compared with 50.8% of patients were on any antiplatelet therapy, and 13.9% compared with 66.7% of patients were on any anticoagulation therapy in TAVR + LAAO compared with TAVR + medical therapy group, respectively. For the composite primary end point, TAVR + LAAO was noninferior to TAVR + medical therapy (22.7 versus 27.3 events per 100 patient-years for TAVR + LAAO and TAVR + medical therapy, respectively; hazard ratio, 0.86 [95% CI, 0.60-1.22]; Pnoninferiority<0.001). CONCLUSIONS: Concomitant WATCHMAN LAAO and TAVR is noninferior to TAVR with medical therapy in severe aortic stenosis patients with AF. The increased complexity and risks of the combined procedure should be considered when concomitant LAAO is viewed as an alternative to medical therapy for patients with AF undergoing TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03173534.


Asunto(s)
Estenosis de la Válvula Aórtica , Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Inhibidores de Agregación Plaquetaria/efectos adversos , Apéndice Atrial/cirugía , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Hemorragia/inducido químicamente , Anticoagulantes/efectos adversos , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento
4.
N Engl J Med ; 387(14): 1253-1263, 2022 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-36121045

RESUMEN

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) for the treatment of aortic stenosis can lead to embolization of debris. Capture of debris by devices that provide cerebral embolic protection (CEP) may reduce the risk of stroke. METHODS: We randomly assigned patients with aortic stenosis in a 1:1 ratio to undergo transfemoral TAVR with CEP (CEP group) or without CEP (control group). The primary end point was stroke within 72 hours after TAVR or before discharge (whichever came first) in the intention-to-treat population. Disabling stroke, death, transient ischemic attack, delirium, major or minor vascular complications at the CEP access site, and acute kidney injury were also assessed. A neurology professional examined all the patients at baseline and after TAVR. RESULTS: A total of 3000 patients across North America, Europe, and Australia underwent randomization; 1501 were assigned to the CEP group and 1499 to the control group. A CEP device was successfully deployed in 1406 of the 1489 patients (94.4%) in whom an attempt was made. The incidence of stroke within 72 hours after TAVR or before discharge did not differ significantly between the CEP group and the control group (2.3% vs. 2.9%; difference, -0.6 percentage points; 95% confidence interval, -1.7 to 0.5; P = 0.30). Disabling stroke occurred in 0.5% of the patients in the CEP group and in 1.3% of those in the control group. There were no substantial differences between the CEP group and the control group in the percentage of patients who died (0.5% vs. 0.3%); had a stroke, a transient ischemic attack, or delirium (3.1% vs. 3.7%); or had acute kidney injury (0.5% vs. 0.5%). One patient (0.1%) had a vascular complication at the CEP access site. CONCLUSIONS: Among patients with aortic stenosis undergoing transfemoral TAVR, the use of CEP did not have a significant effect on the incidence of periprocedural stroke, but on the basis of the 95% confidence interval around this outcome, the results may not rule out a benefit of CEP during TAVR. (Funded by Boston Scientific; PROTECTED TAVR ClinicalTrials.gov number, NCT04149535.).


Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Embolia Intracraneal , Implantación de Prótesis , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Lesión Renal Aguda/etiología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Delirio/etiología , Humanos , Embolia Intracraneal/etiología , Embolia Intracraneal/prevención & control , Ataque Isquémico Transitorio/etiología , Implantación de Prótesis/instrumentación , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
5.
Eur Heart J ; 45(21): 1890-1900, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38270189

RESUMEN

BACKGROUND AND AIMS: In transcatheter aortic valve replacement (TAVR) recipients, the optimal management of concomitant chronic obstructive coronary artery disease (CAD) remains unknown. Some advocate for pre-TAVR percutaneous coronary intervention, while others manage it expectantly. The aim of this study was to assess the impact of varying degrees and extent of untreated chronic obstructive CAD on TAVR and longer-term outcomes. METHODS: The authors conducted a retrospective cohort study of TAVR recipients from January 2015 to November 2021, separating patients into stable non-obstructive or varying degrees of obstructive CAD. The major outcomes of interest were procedural all-cause mortality and complications, major adverse cardiovascular events, and post-TAVR unplanned coronary revascularization. RESULTS: Of the 1911 patients meeting inclusion, 75%, 6%, 10%, and 9% had non-obstructive, intermediate-risk, high-risk, and extreme-risk CAD, respectively. Procedural complication rates overall were low (death 0.4%, shock 0.1%, extracorporeal membrane oxygenation 0.1%), with no difference across groups. At a median follow-up of 21 months, rates of acute coronary syndrome and unplanned coronary revascularization were 0.7% and 0.5%, respectively, in the non-obstructive population, rising in incidence with increasing severity of CAD (P < .001 for acute coronary syndrome/unplanned coronary revascularization). Multivariable analysis did not yield a significantly greater risk of all-cause mortality or major adverse cardiovascular events across groups. One-year acute coronary syndrome and unplanned coronary revascularization rates in time-to-event analyses were significantly greater in the non-obstructive (98%) vs. obstructive (94%) subsets (Plog-rank< .001). CONCLUSIONS: Transcatheter aortic valve replacement can be performed safely in patients with untreated chronic obstructive CAD, without portending higher procedural complication rates and with relatively low rates of unplanned coronary revascularization and acute coronary syndrome at 1 year.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Masculino , Femenino , Estudios Retrospectivos , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Anciano , Intervención Coronaria Percutánea , Resultado del Tratamiento , Factores de Riesgo
6.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38703375

RESUMEN

AIMS: Ablation of monomorphic ventricular tachycardia (MMVT) has been shown to reduce shock frequency and improve survival. We aimed to compare cause-specific risk factors for MMVT and polymorphic ventricular tachycardia (PVT)/ventricular fibrillation (VF) and to develop predictive models. METHODS AND RESULTS: The multicentre retrospective cohort study included 2668 patients (age 63.1 ± 13.0 years; 23% female; 78% white; 43% non-ischaemic cardiomyopathy; left ventricular ejection fraction 28.2 ± 11.1%). Cox models were adjusted for demographic characteristics, heart failure severity and treatment, device programming, and electrocardiogram metrics. Global electrical heterogeneity was measured by spatial QRS-T angle (QRSTa), spatial ventricular gradient elevation (SVGel), azimuth, magnitude (SVGmag), and sum absolute QRST integral (SAIQRST). We compared the out-of-sample performance of the lasso and elastic net for Cox proportional hazards and the Fine-Gray competing risk model. During a median follow-up of 4 years, 359 patients experienced their first sustained MMVT with appropriate implantable cardioverter-defibrillator (ICD) therapy, and 129 patients had their first PVT/VF with appropriate ICD shock. The risk of MMVT was associated with wider QRSTa [hazard ratio (HR) 1.16; 95% confidence interval (CI) 1.01-1.34], larger SVGel (HR 1.17; 95% CI 1.05-1.30), and smaller SVGmag (HR 0.74; 95% CI 0.63-0.86) and SAIQRST (HR 0.84; 95% CI 0.71-0.99). The best-performing 3-year competing risk Fine-Gray model for MMVT [time-dependent area under the receiver operating characteristic curve (ROC(t)AUC) 0.728; 95% CI 0.668-0.788] identified high-risk (> 50%) patients with 75% sensitivity and 65% specificity, and PVT/VF prediction model had ROC(t)AUC 0.915 (95% CI 0.868-0.962), both satisfactory calibration. CONCLUSION: We developed and validated models to predict the competing risks of MMVT or PVT/VF that could inform procedural planning and future randomized controlled trials of prophylactic ventricular tachycardia ablation. CLINICAL TRIAL REGISTRATION: URL:www.clinicaltrials.gov Unique identifier:NCT03210883.


Asunto(s)
Desfibriladores Implantables , Prevención Primaria , Taquicardia Ventricular , Fibrilación Ventricular , Humanos , Femenino , Masculino , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/prevención & control , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Persona de Mediana Edad , Estudios Retrospectivos , Prevención Primaria/métodos , Factores de Riesgo , Medición de Riesgo , Anciano , Fibrilación Ventricular/prevención & control , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/fisiopatología , Fibrilación Ventricular/terapia , Resultado del Tratamiento , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Electrocardiografía , Ablación por Catéter , Factores de Tiempo , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología
7.
Catheter Cardiovasc Interv ; 102(6): 1149-1153, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37855217

RESUMEN

Left ventricular outflow tract (LVOT) obstruction from the displaced prosthetic anterior mitral leaflet is a life-threatening complication that can occur during valve-in-valve (ViV) transcatheter mitral valve replacement (TMVR). Laceration of the anterior mitral leaflet to prevent outflow obstruction is a well-established transcatheter technique to mitigate the risk of LVOT obstruction in high-risk anatomies. In this report, we present a novel transseptal technique of prosthetic leaflet modification to prevent LVOT obstruction during ViV TMVR.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Obstrucción del Flujo de Salida Ventricular Izquierda , Obstrucción del Flujo Ventricular Externo , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas/efectos adversos , Factores de Riesgo , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/prevención & control
8.
Catheter Cardiovasc Interv ; 101(1): 187-196, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36378620

RESUMEN

BACKGROUND: New-onset left bundle branch block (LBBB) can develop after transcatheter aortic valve replacement (TAVR) resulting in worse outcomes. AIMS: Describe clinical and echocardiographic outcomes with new-onset LBBB after TAVR. METHODS: We included consecutive patients who underwent transfemoral-TAVR with SAPIEN-3 (S3) valve between April 2015 and December 2018. Exclusion criteria included pre-existing LBBB, right BBB, left anterior hemiblock, left posterior hemiblock, wide QRS ≥ 120ms, prior permanent pacemaker (PPM), and nontransfemoral access. RESULTS: Among 612 patients, 11.4% developed new-onset LBBB upon discharge. The length of stay was longer with new-onset LBBB compared with no LBBB [3 (2-5) days versus 2 (1-3) days; p < 0.001]. New-onset LBBB was associated with higher rates of 30-day PPM requirement (18.6% vs. 5.4%; p < 0.001) and 1-year heart failure hospitalizations (10.7% vs. 4.4%; p = 0.033). There was no difference in 3-year mortality between both groups (30.9% vs. 30.6%; p = 0.829). Further, new-onset LBBB was associated with lower left ventricular ejection fraction (LVEF) at both 30 days (55.9 ± 11.4% vs. 59.3 ± 9%; p = 0.026) and 1 year (55 ± 12% vs. 60.1 ± 8.9%; p = 0.002). These changes were still present when we stratified patients according to baseline LVEF (≥50% or <50%). New-onset LBBBs were associated with a higher 1-year LV end-diastolic volume index (51.4 ± 18.6 vs. 46.4 ± 15.1 ml/m2 ; p = 0.036), and LV end-systolic volume index (23.2 ± 14.1 vs. 18.9 ± 9.7 ml/m2 ; p = 0.009). Compared with resolved new-onset LBBB, persistent new-onset LBBB was associated with worse LVEF and higher PPM at 1 year. CONCLUSIONS: New-onset LBBB after S3 TAVR was associated with higher PPM requirement, worse LVEF, higher LV volumes, and increased heart failure hospitalizations, with no difference in mortality.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Volumen Sistólico , Función Ventricular Izquierda , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Arritmias Cardíacas , Ecocardiografía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
9.
Echocardiography ; 40(4): 318-326, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36859633

RESUMEN

BACKGROUND: The implications of left ventricular remodeling and dysfunction before and after aortic valve replacement (AVR) for mixed aortic valve disease (MAVD) are not well understood. This study aims to evaluate the impact of AVR on left ventricular (LV) systolic function in MAVD, and determine the prognostic value of postoperative LV global longitudinal strain (LV-GLS) and LV ejection fraction (LVEF). METHODS: We retrospectively assessed 489 consecutive patients with MAVD (defined as at least moderate aortic stenosis and at least moderate aortic regurgitation) and baseline LVEF ≥50%, who underwent AVR between February 2003 and August 2018. All patients had baseline echocardiography, whereas 192 patients underwent postoperative echocardiography between 3 and 18 months after AVR. The primary endpoint was all-cause mortality. RESULTS: Mean age was 65 ± 15 years, and 65% were male. AVR in MAVD patients has a neutral effect on LV systolic function quantitated by LVEF and LV-GLS. During a median follow-up period of 5.8 years, 65 patients (34%) of 192 patients with follow-up echocardiography died. The patients with postoperative LVEF ≥50% had better survival than those with postoperative LVEF <50% (P < .001). Furthermore, among patients with postoperative LVEF ≥50%, mortality differed between patients with postoperative LV-GLS worse than -15% and those with postoperative LV-GLS better than -15% (P < .001). CONCLUSIONS: In patients with MAVD who underwent AVR, the mean postoperative LV-GLS and LVEF remain at a similar value to baseline. However, worse postoperative LV-GLS and LVEF were both independently associated with higher mortality in this population.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Disfunción Ventricular Izquierda , Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Pronóstico , Estudios Retrospectivos , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Disfunción Ventricular Izquierda/complicaciones , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Volumen Sistólico
10.
Curr Cardiol Rep ; 25(8): 807-816, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37493873

RESUMEN

PURPOSE OF REVIEW: The dicrotic notch (DN) has long been considered a marker of arterial stiffness and compliance. Herein, we explored the recent developments in vascular medicine research in an attempt to assess the DN utility in clinical cardiovascular medicine. RECENT FINDINGS: Since its discovery, several studies have attempted to measure the changes in different parameters of the DN in physiological and pathological states. Despite the significance of their findings, the clinical role of the DN remained limited. This may have been related to the difficulty of measuring the DN via indwelling arterial catheters in the past. However, over the past two decades, several non-invasive methods have been developed, which may re-ignite interest in DN research. The DN may have broader applications in clinical cardiovascular medicine. Further research is needed to establish the accuracy of DN non-invasive measurement methods and compare its prognostic value to other circulatory parameters.

11.
Clin Anat ; 36(5): 836-846, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36864653

RESUMEN

The ventricular components of the conduction axis remain vulnerable following transcatheter aortic valvar replacement. We aimed to describe features which may be used accurately by interventionalists to predict the precise location of the conduction axis, hoping better to avoid conduction disturbances. We scanned eight normal adult heart specimens by 3T magnetic resonance, using the images to simulate histological sections in order accurately to place the conduction axis back within the heart. We then used histology, tested in two pediatric hearts, to prepare sections, validated by the magnetic resonance images, to reveal the key relationships between the conduction axis and the aortic root. The axis was shown to have a close relationship to the nadir of the right coronary leaflet, in particular when the aortic root was rotated in counterclockwise fashion. The axis was more vulnerable in the setting of a narrow inferoseptal recess, when the inferior margin of the membranous septum was above the plane of the virtual basal ring, and when minimal myocardium was supporting the right coronary sinus. The features identified in our study are in keeping with the original description provided by Tawara, but at variance with more recent accounts. They suggest that the vulnerability of the axis during transcatheter valvar replacement can potentially be inferred on the basis of knowledge of the position of the aortic root within the ventricular base. If validated by clinical studies, our findings may better permit avoidance of new-onset left bundle branch block following transcatheter aortic valvar replacement.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Adulto , Humanos , Niño , Corazón , Bloqueo de Rama , Ventrículos Cardíacos , Aorta , Resultado del Tratamiento , Válvula Aórtica/cirugía
12.
N Engl J Med ; 380(18): 1695-1705, 2019 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-30883058

RESUMEN

BACKGROUND: Among patients with aortic stenosis who are at intermediate or high risk for death with surgery, major outcomes are similar with transcatheter aortic-valve replacement (TAVR) and surgical aortic-valve replacement. There is insufficient evidence regarding the comparison of the two procedures in patients who are at low risk. METHODS: We randomly assigned patients with severe aortic stenosis and low surgical risk to undergo either TAVR with transfemoral placement of a balloon-expandable valve or surgery. The primary end point was a composite of death, stroke, or rehospitalization at 1 year. Both noninferiority testing (with a prespecified margin of 6 percentage points) and superiority testing were performed in the as-treated population. RESULTS: At 71 centers, 1000 patients underwent randomization. The mean age of the patients was 73 years, and the mean Society of Thoracic Surgeons risk score was 1.9% (with scores ranging from 0 to 100% and higher scores indicating a greater risk of death within 30 days after the procedure). The Kaplan-Meier estimate of the rate of the primary composite end point at 1 year was significantly lower in the TAVR group than in the surgery group (8.5% vs. 15.1%; absolute difference, -6.6 percentage points; 95% confidence interval [CI], -10.8 to -2.5; P<0.001 for noninferiority; hazard ratio, 0.54; 95% CI, 0.37 to 0.79; P = 0.001 for superiority). At 30 days, TAVR resulted in a lower rate of stroke than surgery (P = 0.02) and in lower rates of death or stroke (P = 0.01) and new-onset atrial fibrillation (P<0.001). TAVR also resulted in a shorter index hospitalization than surgery (P<0.001) and in a lower risk of a poor treatment outcome (death or a low Kansas City Cardiomyopathy Questionnaire score) at 30 days (P<0.001). There were no significant between-group differences in major vascular complications, new permanent pacemaker insertions, or moderate or severe paravalvular regurgitation. CONCLUSIONS: Among patients with severe aortic stenosis who were at low surgical risk, the rate of the composite of death, stroke, or rehospitalization at 1 year was significantly lower with TAVR than with surgery. (Funded by Edwards Lifesciences; PARTNER 3 ClinicalTrials.gov number, NCT02675114.).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Readmisión del Paciente/estadística & datos numéricos , Complicaciones Posoperatorias/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Fibrilación Atrial/etiología , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Estimación de Kaplan-Meier , Tiempo de Internación , Masculino , Diseño de Prótesis , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
13.
Am J Physiol Heart Circ Physiol ; 322(1): H94-H104, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34860593

RESUMEN

Dobutamine stress echocardiography (DSE) is a useful tool for assessing low-gradient significant aortic stenosis (AS) and contractile reserve (CR), but its prognostic utility has become controversial in recent studies. We evaluated the impact of DSE on aortic valve physiological, structural, and left ventricular parameters in low-gradient AS. Consecutive patients undergoing DSE for low-gradient AS evaluation from September 2010 to July 2016 were retrospectively studied, and DSE findings were divided into four groups: with and without severe AS and/or CR. Relationships between left ventricular chamber quantification, CR, aortic valve Doppler during DSE, and calcium score [by computerized tomography (CT)] were analyzed. There were 258 DSE studies performed on 243 patients, mean age 77.6 ± 10.8 yr and 183 (70.1%) were males. With increasing dobutamine dose, apart from systolic blood pressure, left ventricular ejection fraction, flow, cardiac power output, and longitudinal strain magnitude, along with aortic valve area and mean aortic gradient were all significantly increased (P < 0.05). Flow and mean gradient increased in both the presence and absence of CR, whereas stroke volume and aortic valve area increased mainly in those with CR only. The aortic valve area increased in both patients with low and high calcium scores; however, the baseline area was lower in those with a higher calcium score. During DSE, aortic valve area increases with increase in aortic valve gradient. Higher calcium score is associated with lower baseline aortic valve area, but the aortic valve area still increases with dobutamine even in presence of a high calcium score.NEW & NOTEWORTHY We show that even in most severe aortic stenosis, there is some residual valve pliability. This suggests that a complete loss of pliability is not compatible with survival.


Asunto(s)
Agonistas de Receptores Adrenérgicos beta 1/farmacología , Estenosis de la Válvula Aórtica/fisiopatología , Dobutamina/farmacología , Ecocardiografía/efectos adversos , Prueba de Esfuerzo/efectos adversos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Presión Sanguínea , Ecocardiografía/métodos , Prueba de Esfuerzo/métodos , Femenino , Corazón/efectos de los fármacos , Corazón/fisiopatología , Humanos , Masculino , Contracción Miocárdica , Volumen Sistólico
14.
Catheter Cardiovasc Interv ; 99(5): 1592-1596, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35066981

RESUMEN

We assessed the incidence of aortic valve surgery intervention in the treatment of infective endocarditis (IE) after transcatheter aortic valve replacement (TAVR) and compared the characteristics and outcomes of surgical intervention versus medical management alone in this cohort using a nationwide data set. We identified all the hospitalizations in patients undergoing TAVR who developed IE within 1-year (i.e., early IE) of the procedure from 2014 to 2017 using the Nationwide Readmission Database (NRD). The primary outcomes of the study were in-hospital mortality. A total of 906 hospitalizations were identified for IE amongst the TAVR patients from 2014 to 2017 of which 20 (2.21%) underwent aortic valve surgery during the hospitalization. Patients undergoing surgery were younger, more likely to have Staphylococcus aureus endocarditis, cardiogenic shock, and acute kidney injury (AKI) during the hospitalization. There were no significant differences in in-hospital mortality (9.9% vs. 12.4%, p = 0.824; adjusted odds ratio (aOR): 0.26 (0.01-1.58), p = 0.223) and 30-day readmissions. However, the length of stay and hospitalization costs were higher in surgical intervention group. The important predictors of in-hospital mortality in TAVR-related IE patients were dialysis during IE hospitalization, AKI, cardiogenic shock, Staphylococcus aureus endocarditis, stroke, and female sex. The utilization of surgical management for IE post-TAVR during the index hospitalization is low, and there is no significant mortality benefit with surgical intervention as compared with the medical management.


Asunto(s)
Lesión Renal Aguda , Estenosis de la Válvula Aórtica , Endocarditis Bacteriana , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Infecciones Estafilocócicas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Endocarditis/diagnóstico , Endocarditis/cirugía , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/cirugía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Mortalidad Hospitalaria , Humanos , Masculino , Factores de Riesgo , Choque Cardiogénico/cirugía , Infecciones Estafilocócicas/complicaciones , Infecciones Estafilocócicas/diagnóstico , Infecciones Estafilocócicas/terapia , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
15.
Artículo en Inglés | MEDLINE | ID: mdl-36511393

RESUMEN

BACKGROUND: The newest-generation balloon-expandable valve, SAPIEN 3 Ultra (S3U), is expected to function well with the enhanced sealing skirt compared with SAPIEN 3 (S3). However, current literature on the comparison between these two valves is limited to short-term follow-ups. Therefore, we aimed to evaluate the 1-year outcomes and echocardiographic changes of S3U compared with S3. METHODS: We retrospectively identified patients who underwent transfemoral-transcatheter aortic valve replacement with S3U or S3 (20/23/26 mm) at our institution in 2018-2020. Outcomes were 1-year clinical events and echocardiographic parameters, and were compared between S3U and S3 after adjustment with inverse probability of treatment weighting. RESULTS: The S3U and S3 groups included 297 (25.7%) and 858 (74.3%) patients, respectively. There were no significant differences between the two groups in clinical events (death 5.8% vs. 5.5%, hazard ratio [HR] 1.07, 95% confidence interval [CI] 0.81-1.90; death or heart failure hospitalization 10.3% vs. 10.1%, HR 1.04, 95% CI 0.67-1.62). The S3U group had a lower prevalence of mild paravalvular leakage (PVL) (13.7% vs. 22.3%, p = 0.044), with similar moderate PVL (0.7% vs. 1.2%, p > 0.99). No significant differences were observed in aortic valve mean gradient and Doppler velocity index at 1 year. However, the S3U group had a larger increase in mean gradient from implantation to 1 year (median +4.70 vs. +1.63 mmHg, p < 0.001). CONCLUSIONS: S3U and S3 carried similarly favorable clinical event risks. Nonetheless, S3U was associated with less frequent mild PVL but a larger increase in transprosthetic gradient. Further studies are needed to determine the prognostic impact of these hemodynamic differences.

16.
Catheter Cardiovasc Interv ; 99(1): 160-168, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34184817

RESUMEN

OBJECTIVES: This study sought to examine the association of hospital procedural volume with the incidence and outcomes of surgical bailout (SB) in patients who undergo transcatheter aortic valve replacement (TAVR). BACKGROUND: SB is required for serious complications during or after TAVR. It remains unclear whether hospital experiences affect the incidence and outcomes of SB. METHODS: We retrospectively identified patients who underwent endovascular TAVR using the Nationwide Readmissions Database 2012-2017. We examined the association of annual hospital procedural volume (annual number of endovascular TAVR cases in each hospital in each year) with the incidence and in-hospital mortality of SB using multivariable logistic regressions and restricted cubic splines. RESULTS: Among 82,764 eligible patients, the incidence of SB was 0.95% (n = 789) and decreased from 2012 to 2017 (from 2.66% to 0.49%; Ptrend < 0.001), while in-hospital mortality of SB remained high over years (from 26.0% to 23.5%; Ptrend  = 0.773). Very-high-volume hospitals (≥200 cases/year), as compared with low-volume hospitals (≤49 cases/year), showed significantly a lower incidence of SB (0.49% vs. 1.81%; adjusted OR = 0.28, 95% CI = 0.21-0.38), but similar in-hospital mortality of SB (26.2% vs. 25.6%; adjusted OR = 0.88, 95% CI = 0.47-1.66). There was a significant nonlinear, inverse association of hospital volume with the incidence of SB, but not with the in-hospital mortality of SB. CONCLUSIONS: Hospitals with higher TAVR volumes have a lower risk of SB, but the in-hospital mortality after SB does not change with hospital TAVR volume. Our findings highlight the importance that physicians should always be aware of the high mortality risk of SB following TAVR regardless of hospital procedural experiences.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Mortalidad Hospitalaria , Hospitales de Bajo Volumen , Humanos , Incidencia , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
17.
Catheter Cardiovasc Interv ; 99(6): 1877-1885, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35289473

RESUMEN

OBJECTIVES: The purpose of this study is to investigate the viability of transcatheter aortic valve replacement (TAVR) for severe symptomatic aortic stenosis (AS) in patients with prior chest radiation therapy (cXRT). BACKGROUND: Since patients with prior cXRT perform poorly with surgical aortic valve replacement, TAVR can be a viable alternative. However, clinical outcomes after TAVR in this patient population have not been well studied. METHODS: From the pooled registry of the placement of aortic transcatheter valves II trial, we identified patients with and without prior cXRT who underwent TAVR (n = 64 and 3923, respectively). The primary outcome was a composite of all-cause death and any stroke at 2 years. Time to event analyses were shown as Kaplan-Meier event rates and compared by log-rank testing. Hazard ratios (HRs) were estimated and compared by Cox proportional hazards regression model. RESULTS: There was no significant difference in the primary outcome between the patients with and without prior cXRT (30.7% vs. 27.0%; p = 0.75; HR, 1.08; 95% confidence interval, 0.66-1.77). Rates of myocardial infarction, vascular complications, acute kidney injury, or new pacemaker implant after TAVR were not statistically different between the two groups. The rate of immediate reintervention with a second valve for aortic regurgitation after TAVR was higher among the patients with prior cXRT. However, no further difference was observed during 2 years follow-up after discharge from the index-procedure hospitalization. CONCLUSIONS: TAVR is a viable alternative for severe symptomatic AS in patients who had cXRT in the past.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
18.
Catheter Cardiovasc Interv ; 99(3): 877-888, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34236762

RESUMEN

OBJECTIVES: This study aimed to evaluate the incidence, treatment, and outcomes of acute myocardial infarction (AMI) following transcatheter or surgical aortic valve replacement (TAVR or SAVR). BACKGROUND: Coronary artery disease is common in patients who undergo aortic valve replacement. However, little is known about differences in clinical features of post-TAVR or post-SAVR AMI. METHODS: We retrospectively identified post-TAVR or post-SAVR (including isolated and complex SAVR) patients admitted with AMI using the Nationwide Readmissions Database 2012-2017. Incidence, invasive strategy (coronary angiography or revascularization), and in-hospital outcomes were compared between post-TAVR and post-SAVR AMIs. RESULTS: The incidence of 180-day AMI was higher post-TAVR than post-SAVR (1.59% vs. 0.72%; p < 0.001). Post-TAVR AMI patients (n = 1315), compared with post-SAVR AMI patients (n = 1344), were older, had more comorbidities and more frequent non-ST-elevation AMI (NSTEMI: 86.6% vs. 78.0%; p < 0.001). After propensity-score matching, there was no significant difference in in-hospital mortality between post-TAVR and post-SAVR AMIs (14.7% vs. 16.1%; p = 0.531), but the mortality was high in both groups, particularly in ST-elevation AMI (STEMI: 38.8% vs. 29.2%; p = 0.153). Invasive strategy was used less frequently for post-TAVR AMI than post-SAVR AMI (25.6% vs. 38.3%; p < 0.001). Invasive strategy was associated with lower mortality in both post-TAVR (adjusted odds ratio = 0.40; 95% confidence interval = [0.24-0.66]) and post-SAVR groups (0.60 [0.41-0.88]). CONCLUSIONS: AMI, albeit uncommon, was more frequent post-TAVR than post-SAVR. Patients commonly presented with NSTEMI, but the mortality of STEMI was markedly high. Further studies are needed to understand why a substantial percentage of patients do not receive invasive coronary treatment, particularly after TAVR, despite seemingly better outcomes with invasive strategy.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Infarto del Miocardio con Elevación del ST , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Mortalidad Hospitalaria , Humanos , Incidencia , Estudios Retrospectivos , Factores de Riesgo , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/epidemiología , Infarto del Miocardio con Elevación del ST/terapia , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
19.
Catheter Cardiovasc Interv ; 100(5): 860-867, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36116028

RESUMEN

BACKGROUND: Transcatheter aortic valve-in-valve implantation (ViV-TAVI) has emerged in recent years as a safe alternative to redo surgery in high-risk patients. Although early results are encouraging, data beyond short-term outcomes are lacking. Herein, we aimed to assess the 2-year outcomes after ViV-TAVI. METHODS: Patients undergoing ViV-TAVI for degenerated surgical valves between 2013 and 2019 at the Cleveland Clinic were reviewed. The coprimary endpoints were all-cause mortality and congestive heart failure (CHF) hospitalizations. We used time-to-event analyses to assess the primary outcomes. Further, we measured the changes in transvalvular gradients and the incidence of structural valve deterioration (SVD). RESULTS: One hundred and eighty-eight patients were studied (mean age = 76 years; 65% males). At 2 years of follow-up, all-cause mortality and CHF hospitalizations occurred in 15 (8%) and 28 (14.9%) patients, respectively. On multivariable analysis, the postprocedural length of stay was a significant predictor for both all-cause mortality (hazard ratio [HR] = 1.1; 95% confidence interval [CI]: 1.01, 1.19) and CHF hospitalization (HR = 1.16; 95% CI: 1.07, 1.27). However, the internal diameter of the surgical valve was not associated with significant differences in both primary endpoints. For hemodynamic outcomes, nine patients (4.8%) developed SVD. The mean and peak transvalvular pressure gradients remained stable over the follow-up period. CONCLUSION: ViV-TAVI for degenerated surgical valves was associated with favorable 2-year clinical and hemodynamic outcomes. Further studies are needed to better understand the role of ViV-TAVI as a treatment option in the life management of aortic valve disease.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano , Femenino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Bioprótesis/efectos adversos , Falla de Prótesis , Reoperación/métodos , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Implantación de Prótesis de Válvulas Cardíacas/métodos
20.
Catheter Cardiovasc Interv ; 100(5): 810-820, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35916117

RESUMEN

BACKGROUND: The cerebral embolic protection (CEP) device captures embolic debris during transcatheter aortic valve replacement (TAVR). However, the impact of CEP on stroke severity following TAVR remains unclear. Therefore, we aimed to examine whether CEP was associated with reduced severity of stroke following TAVR. METHODS: This was a retrospective cohort study of 2839 consecutive patients (mean age: 79.2 ± 9.5 years, females: 41.5%) who underwent transfemoral TAVR at our institution between 2013 and 2020. We categorized patients into Sentinel CEP users and nonusers. Neuroimaging data were reviewed and the final diagnosis of a cerebrovascular event was adjudicated by a neurologist blinded to the CEP use or nonuse. We compared the incidence and severity (assessed by the National Institutes of Health Stroke Scale [NIHSS]) of stroke through 72 h post-TAVR or discharge between the two groups using stabilized inverse probability of treatment weighting (IPTW) of propensity scores. RESULTS: Of the eligible patients, 1802 (63.5%) received CEP during TAVR and 1037 (36.5%) did not. After adjustment for patient characteristics by stabilized IPTW, the rate of overall stroke was numerically lower in CEP users than in CEP nonusers, but the difference did not reach statistical significance (0.49% vs. 1.18%, p = 0.064). However, CEP users had significantly lower rates of moderate-or-severe stroke (NIHSS ≥ 6: 0.11% vs. 0.69%, p = 0.013) and severe stroke (NIHSS ≥ 15: 0% vs. 0.29%, p = 0.046). Stroke following CEP use (n = 8), compared with stroke following CEP nonuse (n = 15), tended to carry a lower NIHSS (median [IQR], 4.0 [2.0-7.0] vs. 7.0 [4.5-19.0], p = 0.087). Four (26.7%) out of 15 patients with stroke following CEP nonuse died within 30 days, with no death after stroke following CEP use. CONCLUSIONS: CEP use may be associated with attenuated severity of stroke despite no significant difference in overall stroke incidence compared with CEP nonuse. This finding is considered hypothesis-generating and needs to be confirmed in large prospective studies.


Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Embolia Intracraneal , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Anciano , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estudios Prospectivos , Estudios Retrospectivos , Resultado del Tratamiento , Embolia Intracraneal/diagnóstico por imagen , Embolia Intracraneal/epidemiología , Embolia Intracraneal/etiología , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA