Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Proc Natl Acad Sci U S A ; 120(52): e2314808120, 2023 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-38134196

RESUMEN

Infectious virus shedding from individuals infected with severe acute respiratory syndrome-coronavirus 2 (SARS-CoV-2) is used to estimate human-to-human transmission risk. Control of SARS-CoV-2 transmission requires identifying the immune correlates that protect infectious virus shedding. Mucosal immunity prevents infection by SARS-CoV-2, which replicates in the respiratory epithelium and spreads rapidly to other hosts. However, whether mucosal immunity prevents the shedding of the infectious virus in SARS-CoV-2-infected individuals is unknown. We examined the relationship between viral RNA shedding dynamics, duration of infectious virus shedding, and mucosal antibody responses during SARS-CoV-2 infection. Anti-spike secretory IgA antibodies (S-IgA) reduced viral RNA load and infectivity more than anti-spike IgG/IgA antibodies in infected nasopharyngeal samples. Compared with the IgG/IgA response, the anti-spike S-IgA post-infection responses affected the viral RNA shedding dynamics and predicted the duration of infectious virus shedding regardless of the immune history. These findings highlight the importance of anti-spike S-IgA responses in individuals infected with SARS-CoV-2 for preventing infectious virus shedding and SARS-CoV-2 transmission. Developing medical countermeasures to shorten S-IgA response time may help control human-to-human transmission of SARS-CoV-2 infection and prevent future respiratory virus pandemics.


Asunto(s)
COVID-19 , Humanos , SARS-CoV-2 , Esparcimiento de Virus , Formación de Anticuerpos , Tiempo de Reacción , Anticuerpos Antivirales , ARN Viral , Inmunoglobulina G , Inmunoglobulina A , Inmunoglobulina A Secretora
2.
J Shoulder Elbow Surg ; 33(4): 815-822, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37625694

RESUMEN

BACKGROUND: Postoperative rotator cuff retear after arthroscopic rotator cuff repair (ARCR) is still a major problem. Various risk factors such as age, gender, and tear size have been reported. Recently, magnetic resonance imaging-based stump classification was reported as an index of rotator cuff fragility. Although stump type 3 is reported to have a high retear rate, there are few reports on the risk of postoperative retear based on this classification. Machine learning (ML), an artificial intelligence technique, allows for more flexible predictive models than conventional statistical methods and has been applied to predict clinical outcomes. In this study, we used ML to predict postoperative retear risk after ARCR. METHODS: The retrospective case-control study included 353 patients who underwent surgical treatment for complete rotator cuff tear using the suture-bridge technique. Patients who initially presented with retears and traumatic tears were excluded. In study participants, after the initial tear repair, rotator cuff retears were diagnosed by magnetic resonance imaging; Sugaya classification types IV and V were defined as re-tears. Age, gender, stump classification, tear size, Goutallier classification, presence of diabetes, and hyperlipidemia were used for ML parameters to predict the risk of retear. Using Python's Scikit-learn as an ML library, five different AI models (logistic regression, random forest, AdaBoost, CatBoost, LightGBM) were trained on the existing data, and the prediction models were applied to the test dataset. The performance of these ML models was measured by the area under the receiver operating characteristic curve. Additionally, key features affecting retear were evaluated. RESULTS: The area under the receiver operating characteristic curve for logistic regression was 0.78, random forest 0.82, AdaBoost 0.78, CatBoost 0.83, and LightGBM 0.87, respectively for each model. LightGBM showed the highest score. The important factors for model prediction were age, stump classification, and tear size. CONCLUSIONS: The ML classifier model predicted retears after ARCR with high accuracy, and the AI model showed that the most important characteristics affecting retears were age and imaging findings, including stump classification. This model may be able to predict postoperative rotator cuff retears based on clinical features.


Asunto(s)
Laceraciones , Lesiones del Manguito de los Rotadores , Humanos , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/cirugía , Estudios Retrospectivos , Estudios de Casos y Controles , Inteligencia Artificial , Resultado del Tratamiento , Rotura/cirugía , Artroscopía/métodos , Imagen por Resonancia Magnética , Medición de Riesgo , Aprendizaje Automático
3.
Toxicol Ind Health ; 40(3): 117-124, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38225731

RESUMEN

Electret technology was widely used to prevent the airborne transmission of bioaerosols during the COVID-19 pandemic and improve the filtration efficiency of masks and high-efficiency particulate air (HEPA) filters. As alcohol disinfectants are widely used in medical and welfare institutions, concerns about alcohol exposure inactivating electret exist. However, comprehensive alcohol exposure tests have not been conducted on masks and HEPA filters distributed in Japan. Twenty-five types of masks and five types of HEPA filters were subjected to a discharging process according to ISO 16890 to quantitatively elucidate the resistance to alcohol exposure. Measurements of changes in filtration efficiency and pressure drop before and after discharge show that 17 masks (68%) and four HEPA filters (80%) exhibited a significant decrease in filtration efficiency, confirming their vulnerability to alcohol. In addition, a survey (n = 500 Japanese adults, including 30 healthcare professionals) revealed that ∼90% of the general public were unaware that alcohol exposure could degrade masks and air purifiers. Furthermore, 36% of the surveyed healthcare professionals had sprayed alcohol directly onto their masks. The effectiveness of user warnings through product labels and instructions was investigated from the perspective of ensuring the safety of patients and healthcare professionals. Results revealed that the best approach was to describe the extent and duration of the adverse effects caused by disregarding precautions. Increase in awareness of healthcare professionals and general public by authorities and manufacturers through guidelines and warning labels would reduce the risk of inhaling bioaerosols caused by unintentional electret inactivation.


Asunto(s)
Filtros de Aire , Adulto , Humanos , Pandemias , Máscaras , Filtración/métodos , Hospitales , Polvo , Etanol , Comunicación
4.
Sensors (Basel) ; 24(9)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38733018

RESUMEN

Traditionally, angle measurements have been performed using a goniometer, but the complex motion of shoulder movement has made these measurements intricate. The angle of rotation of the shoulder is particularly difficult to measure from an upright position because of the complicated base and moving axes. In this study, we attempted to estimate the shoulder joint internal/external rotation angle using the combination of pose estimation artificial intelligence (AI) and a machine learning model. Videos of the right shoulder of 10 healthy volunteers (10 males, mean age 37.7 years, mean height 168.3 cm, mean weight 72.7 kg, mean BMI 25.6) were recorded and processed into 10,608 images. Parameters were created using the coordinates measured from the posture estimation AI, and these were used to train the machine learning model. The measured values from the smartphone's angle device were used as the true values to create a machine learning model. When measuring the parameters at each angle, we compared the performance of the machine learning model using both linear regression and Light GBM. When the pose estimation AI was trained using linear regression, a correlation coefficient of 0.971 was achieved, with a mean absolute error (MAE) of 5.778. When trained with Light GBM, the correlation coefficient was 0.999 and the MAE was 0.945. This method enables the estimation of internal and external rotation angles from a direct-facing position. This approach is considered to be valuable for analyzing motor movements during sports and rehabilitation.


Asunto(s)
Inteligencia Artificial , Aprendizaje Automático , Rango del Movimiento Articular , Articulación del Hombro , Humanos , Masculino , Adulto , Articulación del Hombro/fisiología , Rango del Movimiento Articular/fisiología , Femenino , Rotación , Postura/fisiología , Computadoras de Mano
5.
Curr Issues Mol Biol ; 45(4): 3434-3445, 2023 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-37185749

RESUMEN

Advanced glycation end-products (AGEs) play a critical supportive role during musculoskeletal disorders via glycosylation and oxidative stress. Though apocynin, identified as a potent and selective inhibitor of NADPH oxidase, has been reported to be involved in pathogen-induced reactive oxygen species (ROS), its role in age-related rotator cuff degeneration has not been well clarified. Therefore, this study aims to evaluate the in vitro effects of apocynin on human rotator cuff-derived cells. Twelve patients with rotator cuff tears (RCTs) participated in the study. Supraspinatus tendons from patients with RCTs were collected and cultured. After the preparation of RC-derived cells, they were divided into four groups (control group, control + apocynin group, AGEs group, AGEs + apocynin group), and gene marker expression, cell viability, and intracellular ROS production were evaluated. The gene expression of NOX, IL-6, and the receptor for AGEs (RAGE) was significantly decreased by apocynin. We also examined the effect of apocynin in vitro. The results showed that ROS induction and increasing apoptotic cells after treatment of AGEs were significantly decreased, and cell viability increased considerably. These results suggest that apocynin can effectively reduce AGE-induced oxidative stress by inhibiting NOX activation. Thus, apocynin is a potential prodrug in preventing degenerative changes of the rotor cuff.

6.
Mol Biol Rep ; 50(12): 10339-10349, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37982930

RESUMEN

BACKGROUND: Advanced glycation end products (AGEs) are compounds formed due to aging and diabetes mellitus (DM). They activate NADPH oxidase (NOX) by binding to their receptors, thereby increasing the production of reactive oxygen species (ROS), which cause oxidative stress. In this study, we investigated the effects of AGEs on the tissues of the shoulder joint (such as rotator cuff synovium, and capsule) in patients with DM having rotator cuff tears. METHODS: This study included eight patients with DM who underwent surgical treatment for rotator cuff tears with contracture. The rotator cuff, synovium, and joint capsule were harvested at the time of surgery and evaluated by hematoxylin-eosin staining. Furthermore, immunostaining was used for evaluating AGEs and receptor for AGEs (RAGE), cell activity, ROS, and apoptosis. Quantitative real-time polymerase chain reaction (qPCR) was employed for the cellular evaluation of NOX, interleukins, RAGE, and collagen. RESULTS: The AGEs and RAGE staining as well as the ratio of ROS and apoptosis were in the following order: rotator cuff > joint capsule > synovium. In contrast, the cellular activity was significantly higher in the synovium than in the other regions. The type I collagen expression (as shown by qPCR) as well as the RAGE and NOX expressions were as follows: rotator cuff > joint capsule > synovium. Conversely, the expression of inflammatory cytokines (i.e., IL-6 and IL-1ß) was higher in the synovium than in the other regions. CONCLUSIONS: Our study is among the first to evaluate the effects of AGEs on each tissue of the shoulder joint in patients with DM having rotator cuff tears and contractures. The accumulation of AGEs in each tissue of the shoulder joint could reveal the locations affected by DM, which can lead to a better understanding of the pathophysiology of DM-related shoulder diseases.


Asunto(s)
Contractura , Diabetes Mellitus , Lesiones del Manguito de los Rotadores , Humanos , Lesiones del Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/metabolismo , Especies Reactivas de Oxígeno/metabolismo , Manguito de los Rotadores/metabolismo , Diabetes Mellitus/metabolismo , Productos Finales de Glicación Avanzada/metabolismo
7.
Sensors (Basel) ; 23(14)2023 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-37514738

RESUMEN

Substantial advancements in markerless motion capture accuracy exist, but discrepancies persist when measuring joint angles compared to those taken with a goniometer. This study integrates machine learning techniques with markerless motion capture, with an aim to enhance this accuracy. Two artificial intelligence-based libraries-MediaPipe and LightGBM-were employed in executing markerless motion capture and shoulder abduction angle estimation. The motion of ten healthy volunteers was captured using smartphone cameras with right shoulder abduction angles ranging from 10° to 160°. The cameras were set diagonally at 45°, 30°, 15°, 0°, -15°, or -30° relative to the participant situated at a distance of 3 m. To estimate the abduction angle, machine learning models were developed considering the angle data from the goniometer as the ground truth. The model performance was evaluated using the coefficient of determination R2 and mean absolute percentage error, which were 0.988 and 1.539%, respectively, for the trained model. This approach could estimate the shoulder abduction angle, even if the camera was positioned diagonally with respect to the object. Thus, the proposed models can be utilized for the real-time estimation of shoulder motion during rehabilitation or sports motion.


Asunto(s)
Articulación del Hombro , Hombro , Humanos , Inteligencia Artificial , Rango del Movimiento Articular , Postura , Fenómenos Biomecánicos
8.
Sensors (Basel) ; 23(8)2023 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-37112354

RESUMEN

The coracohumeral ligament (CHL) is related to the range of motion of the shoulder joint. The evaluation of the CHL using ultrasonography (US) has been reported on the elastic modulus and thickness of the CHL, but no dynamic evaluation method has been established. We aimed to quantify the movement of the CHL by applying Particle Image Velocimetry (PIV), a technique used in the field of fluid engineering, to cases of shoulder contracture using the US. The subjects were eight patients, with 16 shoulders. The coracoid process was identified from the body surface, and a long-axis US image of the CHL parallel to the subscapularis tendon was drawn. The shoulder joint was moved from 0 degrees of internal/external rotation to 60 degrees of internal rotation at a rhythm of one reciprocation every 2 s. The velocity of the CHL movement was quantified by the PIV method. The mean magnitude velocity of CHL was significantly faster on the healthy side. The maximum magnitude velocity was significantly faster on the healthy side. The results suggest that the PIV method is helpful as a dynamic evaluation method, and in patients with shoulder contracture, the CHL velocity was significantly decreased.


Asunto(s)
Contractura , Articulación del Hombro , Humanos , Articulación del Hombro/diagnóstico por imagen , Hombro/diagnóstico por imagen , Ligamentos Articulares/diagnóstico por imagen , Ultrasonografía , Rango del Movimiento Articular , Contractura/diagnóstico por imagen
9.
BMC Musculoskelet Disord ; 23(1): 271, 2022 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-35317765

RESUMEN

BACKGROUND: Most degenerative rotator cuff tears (RCTs) are associated with a limited range of motion (ROM) of the shoulder joint. Additionally, patients with diabetes mellitus (DM) show a higher frequency of limited ROM. Recently, advanced glycation end products (AGEs) of proteins have been observed to cause tissue fibrosis, primarily through abnormal collagen cross-linking and oxidative stress. In this study, we investigated the effect of AGEs on ROM limitation in the shoulder capsule and its relationship with DM in the patients with RCTs. METHODS: Sixteen patients (eight in the DM and non-DM groups) who underwent arthroscopic surgery for RCT with limited shoulder ROM were included in this study. AGE-related pathologies in both groups were compared, and the relationship between AGE accumulation and shoulder joint ROM was evaluated. Shoulder capsule tissue was harvested and subjected to histological and in vitro evaluation. RESULTS: The DM group displayed high levels of AGEs and reactive oxygen species (ROS), and reduced cell viability. There was a significant positive correlation between ROS expression, apoptosis, and preoperative hemoglobin A1c. ROS expression, apoptosis, and ROM of the shoulder joint showed a negative correlation. The NADPH oxidase (NOX) expression and collagen III/I ratio were significantly higher in the DM group than in the non-DM group. CONCLUSIONS: The DM group showed significant AGEs deposition in the shoulder capsule. Additionally, there was a significant association between AGEs and ROM limitation. Collectively, the findings suggest that the oxidative stress induced by AGEs deposition, which leads to fibrosis and local inflammation, might contribute to the limited ROM of the shoulder joint in patients with RCTs accompanied by DM.


Asunto(s)
Diabetes Mellitus , Lesiones del Manguito de los Rotadores , Articulación del Hombro , Productos Finales de Glicación Avanzada/metabolismo , Humanos , Rango del Movimiento Articular , Lesiones del Manguito de los Rotadores/complicaciones , Lesiones del Manguito de los Rotadores/metabolismo , Lesiones del Manguito de los Rotadores/cirugía , Articulación del Hombro/cirugía
10.
J Shoulder Elbow Surg ; 31(12): 2629-2637, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35961498

RESUMEN

BACKGROUND: Large and massive rotator cuff tears are challenging for surgeons because of postoperative complications such as repaired site retears. Recently, collagen extracted from fish scales has gained more attention because fish byproducts are considered a safer collagen source than other animal-derived scaffolds. This study aimed to evaluate the biological efficacy of tilapia scale-derived collagen scaffolds for rotator cuff repair in rat models. METHODS: The infraspinatus tendon was resected from the greater tuberosity of Sprague-Dawley rats. In the control group, the tendon edge was sutured directly to the humeral head. In the augmentation group, the repaired site was augmented with a tilapia scale-derived collagen scaffold. Histologic examinations were performed at 2 and 4 weeks postoperatively via safranin O and immunofluorescence staining (isolectin B4 and type II collagen) in the bone-tendon junction. For mechanical analysis, the ultimate failure load of the tendon-humeral head complex was evaluated at 6 weeks postoperatively. RESULTS: During safranin O staining, the repaired enthesis demonstrated greater proteoglycan staining in the augmentation group than in the control group at 4 weeks postoperatively. Compared to controls, the augmentation group had significantly higher vascular staining with isolectin B4 at 2 and 4 weeks postoperatively, type II collagen expression at 4 weeks postoperatively, and ultimate failure load at 6 weeks postoperatively. CONCLUSION: Augmentation therapy using tilapia scale-derived type I collagen scaffolds promoted angiogenesis and fibrocartilage regeneration at the enthesis and provided higher mechanical strength than controls.


Asunto(s)
Lesiones del Manguito de los Rotadores , Manguito de los Rotadores , Ratas , Animales , Manguito de los Rotadores/cirugía , Manguito de los Rotadores/metabolismo , Colágeno Tipo II , Ratas Sprague-Dawley , Lesiones del Manguito de los Rotadores/cirugía , Colágeno/metabolismo , Lectinas , Fenómenos Biomecánicos
11.
Sensors (Basel) ; 22(21)2022 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-36365914

RESUMEN

The subsheath of the extensor carpi ulnaris (ECU) tendon, a component of the triangular fibrocartilage complex (TFCC), is particularly important as it dynamically stabilizes the distal radioulnar joint. However, the relationship between TFCC injury and ECU dynamics remains unclear. This study aimed to analyze ECU movement and morphology using ultrasonography (US) images. Twenty wrists of patients with TFCC injury, who underwent TFCC repair, were included in the injury group, and 20 wrists of healthy volunteers were in the control group. For static image analysis, curvature and linearity ratios of the ECU in US long-axis images captured during radioulnar deviation were analyzed. For dynamic analysis of the ECU, the wrist was moved from radial deviation to ulnar deviation at a constant speed, and the velocity of the tendon was analyzed using particle image velocimetry. The static analysis showed that the ECU tendon was more curved in ulnar deviation in the injury group than in the control group, and the dynamic analysis showed that only vertical velocity toward the deep side during ulnar deviation was higher in the injury group. These results suggest that TFCC injury caused ECU curvature during ulnar deviation and increased the vertical velocity of the ECU during wrist deviation.


Asunto(s)
Fibrocartílago Triangular , Humanos , Fibrocartílago Triangular/diagnóstico por imagen , Fibrocartílago Triangular/lesiones , Articulación de la Muñeca/diagnóstico por imagen , Tendones/diagnóstico por imagen , Antebrazo , Ultrasonografía
12.
Sensors (Basel) ; 22(1)2022 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-35009887

RESUMEN

The triangular fibrocartilage complex (TFCC) is a significant stabilizer of the distal radioulnar joint. Diagnosing TFCC injury is currently difficult, but ultrasonography (US) has emerged as a low-cost, minimally invasive diagnostic tool. We aimed to quantitatively analyze TFCC by performing motion analysis by using US. Twelve healthy volunteers, comprising 24 wrists (control group), and 15 patients with TFCC Palmer type 1B injuries (injury group) participated. The US transducer was positioned between the ulnar styloid process and triquetrum and was tilted ulnarly 30° from the vertical line. The wrist was then actively moved from 10° of radial deviation to 20° of ulnar deviation in a 60-rounds-per-minute rhythm that was paced by a metronome. The articular disc displacement velocity magnitude was analyzed by using particle image velocimetry fluid measurement software. The mean area of the articular discs was larger on ulnar deviation in the control group. The mean articular disc area on radial deviation was larger in the injury group. The average articular disc velocity magnitude for the injury group was significantly higher than that for the control group. The results suggest that patients with TFCC injury lose articular disc cushioning and static stability, and subsequent abnormal motion can be analyzed by using US.


Asunto(s)
Fibrocartílago Triangular , Traumatismos de la Muñeca , Humanos , Fibrocartílago Triangular/diagnóstico por imagen , Ultrasonografía , Muñeca , Articulación de la Muñeca
13.
BMC Cancer ; 21(1): 57, 2021 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-33435905

RESUMEN

BACKGROUND: Cell-free DNA (cfDNA) genotyping in plasma using the cobas EGFR Mutation Test v2 (cobas) is the first liquid biopsy as a companion diagnosis to identify the EGFR T790M mutation (T790M) after the failure of treatment of EGFR-tyrosine kinase inhibitors (TKIs) (1st generation, gefitinib [G] and erlotinib [E] and 2nd generation, afatinib [A]). This study investigated the clinical utility of a liquid biopsy for patients who acquired resistance to afatinib. METHODS: We prospectively collected plasma from 51 patients who had acquired resistance to afatinib between April 2015 and November 2016 to evaluate the frequency of T790M by cobas and digital droplet PCR (UMIN000025112). Additionally, we retrospectively reviewed 38 patients who tested by cobas in plasma after G/E failure to compare for T790M detection between A and with G/E. RESULTS: The detection rate of EGFR-driver and T790M in plasma in patients treated with A (A group) as a first-line EGFR-TKI was lower than with G/E followed by A (G/E→A group), although the differences were not significant (EGFR-driver: 41% [A] vs. 67% [G/E→A], P=0.1867; and T790M: 8% [A] vs. 17% [G/E→A], P=0.5798). In first-line setting, the detection rate for EGFR-driver and T790M in plasma by cobas was lower in A group than in G/E group, although there was no significant difference (EGFR-driver: 34% [A] vs. 52% [G/E], P=0.2072; and T790M: 10% [A] vs. 27% [G/E], P=0.1161). CONCLUSION: The detection of EGFR-driver and T790M in plasma by cobas in patients treated with afatinib might be lower than with G/E in a real-world setting.


Asunto(s)
Afatinib/farmacología , Carcinoma de Pulmón de Células no Pequeñas/patología , Resistencia a Antineoplásicos/genética , Amplificación de Genes , Biopsia Líquida/métodos , Mutación , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores de Tumor/sangre , Biomarcadores de Tumor/genética , Carcinoma de Pulmón de Células no Pequeñas/sangre , Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Carcinoma de Pulmón de Células no Pequeñas/genética , Receptores ErbB/genética , Femenino , Estudios de Seguimiento , Humanos , Neoplasias Pulmonares/sangre , Neoplasias Pulmonares/tratamiento farmacológico , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Inhibidores de Proteínas Quinasas/farmacología , Estudios Retrospectivos , Tasa de Supervivencia
14.
Respiration ; 95(4): 251-257, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29320774

RESUMEN

BACKGROUND: While endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is widely used as an initial diagnostic procedure for pathological confirmation of sarcoidosis, it is unclear how many passes are required to obtain diagnostic materials. OBJECTIVES: The aim of this study was to determine the number of needle passes needed for the diagnosis of stage I/II sarcoidosis using EBUS-TBNA. METHODS: At three institutions, 109 patients with suspected stage I/II sarcoidosis were recruited and underwent 6 passes of EBUS-TBNA for the main target lesion. Additional EBUS-TBNA for other lesions was permitted. The cumulative yields of needle passes for detecting noncaseating epithelioid cell granulomas were analyzed. RESULTS: A total of 109 patients underwent EBUS-TBNA for 184 lesions. EBUS-TBNA identified specimens containing granulomas in 81 of 92 patients (88%) with a final diagnosis of sarcoidosis. The cumulative yields through the first, second, third, fourth, fifth, and sixth passes for the main target lesion were 63, 75, 82, 85, 86 and 88%, respectively. In the 55 patients that underwent EBUS-TBNA for multiple lesions, the cumulative yields of 2 passes per lesion for 2 lesions (total of 4 passes) and of 4 passes for single lesions were 86 and 84%, respectively (p = 1.00). CONCLUSIONS: If rapid on-site cytological evaluation is not available, we recommend at least 4 passes per patient for either single or multiple lesions with EBUS-TBNA for pathological diagnosis of stage I/II sarcoidosis.


Asunto(s)
Broncoscopía/estadística & datos numéricos , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/estadística & datos numéricos , Sarcoidosis Pulmonar/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
15.
Cureus ; 16(5): e59657, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38707751

RESUMEN

MediaPipe Hand (MediaPipe) is an artificial intelligence (AI)-based pose estimation library. In this study, MediaPipe was combined with four machine learning (ML) models to estimate the rotation angle of the thumb. Videos of the right hands of 15 healthy volunteers were recorded and processed into 9000 images. The rotation angle of the thumb (defined as angle θ from the palmar plane, which is defined as 0°) was measured using an angle measuring device, expressed in a radian system. Angle θ was then estimated by the ML model by using parameters calculated from the hand coordinates detected by MediaPipe. The linear regression model showed a root mean square error (RMSE) of 12.23, a mean absolute error (MAE) of 9.9, and a correlation coefficient of 0.91. The ElasticNet model showed an RMSE of 12.23, an MAE of 9.95, and a correlation coefficient of 0.91; the support vector machine (SVM) model showed an RMSE of 4.7, an MAE of 2.5, and a correlation coefficient of 0.99. The LightGBM model achieved high values: an RMSE of 4.58, an MAE of 2.62, and a correlation coefficient of 0.99. Based on these findings, we concluded that the thumb rotation angle can be estimated with high accuracy by combining MediaPipe and ML.

16.
Pediatr Int ; 55(6): 690-5, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23919576

RESUMEN

BACKGROUND: Thrombolytic therapy for coronary aneurysm thrombosis of Kawasaki disease (KD) includes antiplatelet and anticoagulants, i.v. coronary thrombolysis (IVCT), and i.c. thrombolysis (ICT). Therapeutic methods, drugs and doses vary among medical facilities. METHODS AND RESULTS: A nationwide survey of thrombolytic therapy was conducted under the auspices of the Ministry of Health, Labour and Welfare Research Program to Intractable Diseases Research Grants. A secondary survey targeted 14 facilities conducting thrombolytic therapy during a 5 year period (2004-2009). The primary survey investigated performance of thrombolytic therapy for 23 KD patients at 14 facilities, and of these, five with acute myocardial infarction had received ICT and combined therapy. The secondary survey investigated the pre-treatment condition of aneurysm and thrombosis and actual treatment methods. ICT was effective for small thrombi (≤ 10 mm), while IVCT was effective even for giant thrombi (>10 mm). ICT was also effective for thrombi within several hours after formation. CONCLUSION: In the present nationwide survey, thrombolytic therapy was more effective in cases of a shorter duration between thrombus formation and the start of treatment. It was found that many facilities used only IVCT for thrombus alone. Medications given to KD children did not cause serious hemorrhagic complications, unlike in adults. Although doses exceeded recommended levels in many cases, the only complications were nasal bleeding and fever.


Asunto(s)
Aneurisma Coronario/complicaciones , Trombosis Coronaria/tratamiento farmacológico , Trombosis Coronaria/etiología , Síndrome Mucocutáneo Linfonodular/complicaciones , Terapia Trombolítica/métodos , Adolescente , Adulto , Niño , Preescolar , Vasos Coronarios , Femenino , Encuestas de Atención de la Salud , Humanos , Lactante , Inyecciones Intravenosas , Japón , Masculino , Selección de Paciente , Estudios Retrospectivos , Adulto Joven
17.
Bioengineering (Basel) ; 10(3)2023 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-36978668

RESUMEN

The diagnosis of osteoporosis is made by measuring bone mineral density (BMD) using dual-energy X-ray absorptiometry (DXA). Machine learning, one of the artificial intelligence methods, was used to predict low BMD without using DXA in elderly women. Medical records from 2541 females who visited the osteoporosis clinic were used in this study. As hyperparameters for machine learning, patient age, body mass index (BMI), and blood test data were used. As machine learning models, logistic regression, decision tree, random forest, gradient boosting trees, and lightGBM were used. Each model was trained to classify and predict low-BMD patients. The model performance was compared using a confusion matrix. The accuracy of each trained model was 0.772 in logistic regression, 0.739 in the decision tree, 0.775 in the random forest, 0.800 in gradient boosting, and 0.834 in lightGBM. The area under the curve (AUC) was 0.595 in the decision tree, 0.673 in logistic regression, 0.699 in the random forest, 0.840 in gradient boosting, and 0.961, which was the highest, in the lightGBM model. Important features were BMI, age, and the number of platelets. Shapley additive explanation scores in the lightGBM model showed that BMI, age, and ALT were ranked as important features. Among several machine learning models, the lightGBM model showed the best performance in the present research.

18.
Am J Sports Med ; 51(2): 358-366, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36622401

RESUMEN

BACKGROUND: Medical screening using ultrasonography (US) has been performed on young baseball players for early detection of osteochondritis dissecans (OCD) of the humeral capitellum. Deep learning (DL) and artificial intelligence (AI) techniques are widely adopted in the medical imaging research field. PURPOSE/HYPOTHESIS: The purpose of this study was to calculate the diagnostic accuracy using DL for US images of OCD. We hypothesized that using DL for US imaging would improve the prediction accuracy of OCD. STUDY DESIGN: Cohort study (Diagnosis); Level of evidence, 2. METHODS: A total of 40 elbows (mean age of patients, 12.1 years) that were suspected of having OCD at a medical checkup and later confirmed by radiographs and magnetic resonance imaging were included in the study. The affected elbows were used as the OCD group and the contralateral elbows as the control group. From US videos, 100 images per elbow were captured from different angles, and 4000 images of the elbows were prepared for both groups. Of these, 80% were randomly selected by DL models and used as training data; the remaining were used as test data. Transfer learning was conducted using 3 pretrained DL models. The confusion matrix and the area under the receiver operating characteristic curve (AUC) were used to evaluate the model, and the visualization of the areas deemed important by the DL models was also performed. Furthermore, OCD regions were detected using an automatic image recognition model based on DL. RESULTS: Classification of the OCD image by the DL model was performed; the best accuracy score was 0.87; the recall was 1.00. AUC was high for all DL models. Visualization of important features showed that AI predicted the presence of OCD by focusing on the irregularity or discontinuity of the surface of subchondral bone. In the detection of OCD task, the mean average precision was 0.83. CONCLUSION: The DL on US images identified OCD with high accuracy. The important features detected by the DL models correspond to the areas used by clinicians in screening the US images. The OCD was also detected with high accuracy using the object detection model. The AI model may be used in medical screening for OCD.


Asunto(s)
Aprendizaje Profundo , Articulación del Codo , Osteocondritis Disecante , Humanos , Niño , Estudios de Cohortes , Osteocondritis Disecante/patología , Inteligencia Artificial , Húmero/patología , Articulación del Codo/diagnóstico por imagen , Ultrasonografía
19.
Kyobu Geka ; 65(7): 559-62, 2012 Jul.
Artículo en Japonés | MEDLINE | ID: mdl-22750832

RESUMEN

Immunonutrition, which is a therapeutic approach to modulate acute surgical or medical conditions, has been proven to decrease surgical site complications in patients undergoing major elective surgery for upper gastrointestinal and esophageal malignancy. For immunonutrition to be carried out effectively, specific nutrients called pharmaconutrients are quite important. In our case, to enhance the perioperative nutritional status of the patient, special formulas supplemented with specific pharmaconutrients, which are arginine and omega-3 fatty acids, were orally administered. The open thoracic window for chronic empyema caused by postoperative bronchopleural fistula was successfully closed. Perioperative immunonutrition is likely to have beneficial effect in decreasing postoperative infectious complications in high-risk malnourished thoracic surgical patients.


Asunto(s)
Adyuvantes Inmunológicos/administración & dosificación , Arginina/administración & dosificación , Empiema Pleural/cirugía , Nutrición Enteral/métodos , Ácidos Grasos Omega-3/administración & dosificación , Atención Perioperativa/métodos , Administración Oral , Anciano , Procedimientos Quirúrgicos Electivos , Humanos , Masculino , Estado Nutricional , Complicaciones Posoperatorias/prevención & control
20.
mSphere ; 7(4): e0008622, 2022 08 31.
Artículo en Inglés | MEDLINE | ID: mdl-35947419

RESUMEN

Coronavirus disease 2019 (COVID-19) spreads by airborne transmission; therefore, the development and functional evaluation of air-cleaning technologies are essential for infection control. Air filtration using high-efficiency particulate air (HEPA) filters may be effective; however, no quantitative assessment of the effectiveness of these filters in the removal of infectious severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from the air has been reported. To evaluate the removal effect of HEPA filtration on airborne SARS-CoV-2, here, we disseminated infectious SARS-CoV-2 aerosols in a test chamber in a biosafety level 3 facility and filtered the air with a HEPA-filtered air cleaner in the chamber. The air cleaner with the HEPA filter continuously removed the infectious SARS-CoV-2 from the air in a running-time-dependent manner, and the virus capture ratios were 85.38%, 96.03%, and >99.97% at 1, 2, and 7.1 ventilation volumes, respectively. The air-cleaning performance of a HEPA filter coated with an antiviral agent consisting mainly of a monovalent copper compound was also evaluated, and the capture ratio was found to be comparable to that of the conventional HEPA filter. This study provides insights into the proper use and performance of HEPA-filtered air cleaners to prevent the spread of COVID-19. IMPORTANCE Air filtration simulation experiments quantitatively showed that an air cleaner equipped with a HEPA filter can continuously remove SARS-CoV-2 from the air. The capture ratios for SARS-CoV-2 in the air when the air cleaner was equipped with an antiviral-agent-coated HEPA filter were comparable to those with the conventional HEPA filter, and there was little effect on SARS-CoV-2 in the air that passed through the antiviral-reagent-coated HEPA filter.


Asunto(s)
COVID-19 , SARS-CoV-2 , Aire Acondicionado , Antivirales , COVID-19/prevención & control , Filtración , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA