Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Pediatr Transplant ; 28(5): e14807, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38923151

RESUMEN

BACKGROUND: The United Network for Organ Sharing (UNOS) started recording data on intellectual disability status in 2008. This study aimed to characterize the long-term outcomes for children with intellectual disabilities (IDs) undergoing lung transplantation. METHODS: All pediatric patients (under 18 years old) undergoing bilateral lung transplantation were identified using the UNOS database. The patients were grouped into the following categories: no cognitive delay, possible cognitive delay, and definite cognitive delay. The primary endpoint was graft survival at 3-year posttransplantation. Multivariate Cox proportional hazards modeling was used to estimate the independent effect of cognitive disability on graft survival. RESULTS: Five hundred four pediatric patients who underwent lung transplantation between March 2008 and December 2022 were retrospectively analyzed. 59 had a definite cognitive delay (12%), 23 had a possible delay (5%), and 421 had no delay (83%). When comparing these three groups, there was no significant difference in 60-day graft survival (p = 0.4), 3-year graft survival (p = 0.6), 3-year graft survival for patients who survived at least 60-day posttransplantation (p = 0.9), distribution of causes of death (p = 0.24), nor distribution treatment of rejection within 1-year posttransplantation (p = 0.06). CONCLUSIONS: Intellectual disability does not impact long-term outcomes after bilateral lung transplantation. Intellectual disability should not be a contraindication to bilateral lung transplantation on the basis of inferior graft survival.


Asunto(s)
Supervivencia de Injerto , Discapacidad Intelectual , Trasplante de Pulmón , Modelos de Riesgos Proporcionales , Humanos , Discapacidad Intelectual/complicaciones , Femenino , Masculino , Niño , Estudios Retrospectivos , Adolescente , Preescolar , Resultado del Tratamiento , Lactante , Rechazo de Injerto/epidemiología , Estudios de Seguimiento
2.
Clin Transplant ; 29(6): 499-505, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25773536

RESUMEN

BACKGROUND: Left ventricular assist devices (LVADs) as a bridge to transplant (BTT) have been known to cause allosensitization, as measured by panel-reactive antibody (PRA) levels. The goal of this study was to measure the impact of this allosensitization on outcomes. METHODS: Panel-reactive antibodies were analyzed in BTT patients, with sensitization defined as peak PRAs ≥ 10%. Baseline characteristics and outcomes in the two patient groups were evaluated using descriptive statistics, Kaplan-Meier, and regression analysis. RESULTS: Thirty-eight patients were included in the study (17 sensitized vs. 21 non-sensitized). There were more women in the sensitized group (47% vs. 10%, p = 0.023). There was no difference in mean times to high-grade acute cellular rejection (ACR; 18.3 months in sensitized vs. 36.9 months in non-sensitized). Five patients in the sensitized groups developed antibody-mediated rejection (AMR) vs. 0 in the non-sensitized, and all five patients died (Kaplan-Meier log-rank p = 0.024). There was also a significant difference in the incidence of infection at the one- to six-month stage (52.9% vs. 19.0%, p = 0.03). CONCLUSION: Sensitization appears to have a negative effect on mortality. This mortality appears to be concentrated in patients with AMR, and we postulate that the development of AMR in a sensitized patient may be a predictor of mortality.


Asunto(s)
Rechazo de Injerto/inmunología , Antígenos HLA/inmunología , Trasplante de Corazón , Corazón Auxiliar/efectos adversos , Isoanticuerpos/sangre , Adulto , Biomarcadores/sangre , Femenino , Rechazo de Injerto/sangre , Rechazo de Injerto/diagnóstico , Rechazo de Injerto/mortalidad , Trasplante de Corazón/mortalidad , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
3.
Ann Thorac Surg ; 116(6): 1241-1248, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-35835207

RESUMEN

BACKGROUND: Infants account for a significant proportion of pediatric heart transplantation but also suffer from a high waitlist mortality. Donor oversizing by weight-based criteria is common practice in transplantation and is prevalent in this group. We sought to analyze the impact of oversizing on outcomes in infants. METHODS: Infant heart transplantations reported to the United Network for Organ Sharing from January 1994 to September 2019 were retrospectively analyzed. 2384 heart transplantation recipients were divided into quintiles (Q1-Q5) on the basis of donor-to-recipient weight ratio (DRWR). Multivariate Cox regression was used to estimate the effect of DRWR. The primary end point was graft survival at 1 year. RESULTS: The median DRWR for each quintile was 0.90 (0.37-1.04), 1.17 (1.04-1.29), 1.43 (1.29-1.57), 1.74 (1.58-1.97), and 2.28 (1.97-5.00). Pairwise comparisons showed improved survival for Q3 and Q4 over each of the bottom 2 quintiles and the top quintile. Regression analyses found that Q3 and Q4 were protective against graft failure compared with the bottom 2 quintiles. There was no difference in hazard among the top 3 quintiles. Significant covariates included primary diagnosis, ischemia time, serum bilirubin level, transplantation year, mechanical ventilation at transplantation, and extracorporeal membrane oxygenation at transplantation. Sex, female-to-male transplantation, and mechanical circulatory support at transplantation were not significant in univariate analyses. CONCLUSIONS: Modest oversizing by DRWR (1.29-1.97) is associated with increased survival and lower risk in infant heart transplantation. Additional investigation is needed to establish best practices for size matching in this population.


Asunto(s)
Trasplante de Corazón , Donantes de Tejidos , Humanos , Niño , Lactante , Masculino , Femenino , Estudios Retrospectivos , Análisis de Regresión , Sistema de Registros , Supervivencia de Injerto
4.
Ann Biomed Eng ; 51(8): 1738-1746, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36966247

RESUMEN

Single ventricle physiology (SVP) is used to describe any congenital heart lesion that is unable to support independent pulmonary and systemic circulations. Current treatment strategies rely on a series of palliation surgeries that culminate in the Fontan physiology, which relies on the single functioning ventricle to provide systemic circulation while passively routing venous return through the pulmonary circulation. Despite significant reductions in early mortality, the presence of atrioventricular valve (AVV) regurgitation is a key predictor of heart failure in these patients. We sought to evaluate the biomechanical changes associated with the AVV in SVP physiologies. Left and right ventricles were sutured onto patient-derived 3D-printed mounts and mounted into an ex vivo systemic heart simulator capable of reproducing Norwood, Glenn, Fontan and Late Fontan physiologies. We found that the tricuspid anterior leaflet experienced elevated maximum force, average force, and maximum yank compared to the posterior and septal leaflets. Between physiologies, maximum yank was greatest in the Norwood physiology relative to the Glenn, Fontan, and Late Fontan physiologies. These contrasting trends suggest that long- and short-term mechanics of AVV failure in single ventricle differ and that AVV interventions should account for asymmetries in force profiles between leaflets and physiologies.


Asunto(s)
Procedimiento de Fontan , Cardiopatías Congénitas , Humanos , Resultado del Tratamiento , Estudios Retrospectivos , Válvulas Cardíacas , Ventrículos Cardíacos
5.
J Heart Lung Transplant ; 41(12): 1790-1797, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36210265

RESUMEN

BACKGROUND: Predicted Heart Mass (PHM) has emerged as an attractive size matching metric in adult cardiac transplantation. However, since PHM was derived from a healthy adult cohort, its generalizability to the pediatric population is unclear. We hypothesize that PHM can be extended to older adolescents, and potentially broaden the donor pool available to this group. METHODS: The United Network for Organ Sharing database was retrospectively analyzed for patients aged 13 to 18 undergoing heart transplantation. Recipients were divided into quintiles (Q1-Q5) based on donor-to-recipient predicted heart mass ratios (PHMR). Primary end-point was graft survival at 5 years. RESULTS: Two thousand sixty-one adolescent heart transplant recipients between January 1994 and September 2019 were retrospectively analyzed. The median PHMR's for each quintile was 0.84 (0.59-0.92), 0.97 (0.92-1.02), 1.08 (1.02-1.14), 1.21 (1.14-1.30), and 1.44 (1.30-2.31). Kaplan-Meier survival curves demonstrated comparable survival across all quintiles of PHMR (p = 0.9). Multivariate Cox regression showed no significant difference in graft failure of the outer quintiles when compared to the middle quintile (Q1: 1.04 HR, p = 0.80; Q2: 1.02 HR, p = 0.89; Q4: 1.19 HR, p = 0.28; Q5: 1.02 HR, p = 0.89). Significant covariates included transplant year (HR: 0.95, p < 0.0001), serum bilirubin (HR: 1.04, p = 0.0004), ECMO at transplantation (HR: 2.85, p < 0.0001), and underlying diagnosis of dilated cardiomyopathy (vs congenital heart disease, HR: 0.66, p = 0.0004). CONCLUSIONS: Matching by PHM is not associated with survival or risk in adolescent heart transplant recipients. Our results underscore the ongoing need to develop an improved size-matching method in pediatric heart transplantation.


Asunto(s)
Trasplante de Corazón , Obtención de Tejidos y Órganos , Adulto , Adolescente , Niño , Humanos , Estudios Retrospectivos , Trasplante de Corazón/métodos , Donantes de Tejidos , Supervivencia de Injerto
6.
Artículo en Inglés | MEDLINE | ID: mdl-36455710

RESUMEN

We sought to understand how leaflet forces change in response to annular dilation and leaflet tethering (LT) in single ventricle physiology. Explanted fetal bovine tricuspid valves were sutured onto image-derived annuli and ventricular mounts. Control valves (CON) were secured to a size-matched hypoplastic left heart syndrome (HLHS)-type annulus and compared to: (1) normal tricuspid valves secured to a size-matched saddle-shaped annulus, (2) HLHS-type annulus with LT, (3) HLHS-type annulus with annular dilation (dilation valves), or (4) a combined disease model with both dilation and tethering (disease valves). The specimens were tested in a systemic heart simulator at various single ventricle physiologies. Leaflet forces were measured using optical strain sensors sutured to each leaflet edge. Average force in the anterior leaflet was 43.2% lower in CON compared to normal tricuspid valves (P < 0.001). LT resulted in a 6.6% increase in average forces on the anterior leaflet (P = 0.04), 10.7% increase on the posterior leaflet (P = 0.03), and 14.1% increase on the septal leaflet (P < 0.001). In dilation valves, average septal leaflet forces increased relative to the CON by 42.2% (P = 0.01). In disease valves, average leaflet forces increased by 54.8% in the anterior leaflet (P < 0.001), 37.6% in the posterior leaflet (P = 0.03), and 79.9% in the septal leaflet (P < 0.001). The anterior leaflet experiences the highest forces in the normal tricuspid annulus under single ventricle physiology conditions. Annular dilation resulted in an increase in forces on the septal leaflet and LT resulted in an increase in forces across all 3 leaflets. Annular dilation and LT combined resulted in the largest increase in leaflet forces across all 3 leaflets.

7.
World J Pediatr Congenit Heart Surg ; 13(2): 166-174, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35238706

RESUMEN

BACKGROUND: Neo-aortic pulmonary autografts often experience root dilation and valve regurgitation over time. This study seeks to understand the biomechanical differences between aortic and neo-aortic pulmonary roots using a heart simulator. METHODS: Porcine aortic, neo-aortic pulmonary, and pulmonary roots (n = 6) were mounted in a heart simulator (parameters: 100 mm Hg, 37 °C, 70 cycles per minute, 5.0 L/min cardiac output). Echocardiography was used to study root distensibility (percentage change in luminal diameter between systole and diastole) and valve function. Leaflet motion was tracked with high-speed videography. After 30 min in the simulator, leaflet thickness (via cryosectioning), and multiaxial modulus (via lenticular hydrostatic deformation testing) were obtained. RESULTS: There were no significant differences between aortic and neo-aortic pulmonary leaflet motion, including mean opening velocity (218 vs 248 mm/s, P = .27) or mean closing velocity (116 vs 157 mm/s, P = .12). Distensibility was similar between aortic (8.5%, 1.56 mm) and neo-aortic pulmonary (7.8%, 1.12 mm) roots (P = .59). Compared to virgin controls, native pulmonic roots exposed to systemic pressure for 30 min had reduced leaflet thickness (630 vs 385 µm, P = .049) and a reduced Young's modulus (3,125 vs 1,089 kPa, P = .077). In contrast, the aortic roots exposed to pressure displayed no significant difference in aortic leaflet thickness (1,317 vs 1,256 µm, P = .27) or modulus (5,931 vs 3,631 kPa, P = .56). CONCLUSIONS: Neo-aortic pulmonary roots demonstrated equivalence in valve function and distensibility but did experience changes in biomechanical properties and morphology. These changes may contribute to long-term complications associated with the Ross procedure.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Enfermedades de las Válvulas Cardíacas , Válvula Pulmonar , Animales , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Autoinjertos , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Válvula Pulmonar/trasplante , Porcinos , Trasplante Autólogo/efectos adversos
9.
Ann Thorac Surg ; 106(6): e313-e315, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-29807007

RESUMEN

We describe the case of a patient with myasthenia gravis and severe pulmonary emphysema who underwent concomitant bilateral video/robotic-assisted thymectomy with unilateral lung volume reduction surgery. We review the important pathophysiologic considerations that must be appreciated to ensure safe surgery in this unusual situation with two diseases that independently affect the respiratory system-each of which requires preoperative optimization.


Asunto(s)
Neumonectomía/métodos , Enfisema Pulmonar/cirugía , Timectomía/métodos , Femenino , Humanos , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos , Miastenia Gravis/complicaciones , Enfisema Pulmonar/etiología
10.
J Heart Lung Transplant ; 37(9): 1093-1101, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30173824

RESUMEN

BACKGROUND: Severe right ventricular failure necessitating a right ventricular assist device (RVAD) complicates 6% to 11% of left ventricular assist device (LVAD) implants. Patient outcomes for those receiving durable continuous-flow VADs in a biventricular configuration (i.e., BiVAD) have been reported in limited case series. METHODS: Data from United States centers with ≥ 6 BiVAD implants were collected. Characteristics and outcomes of patients receiving contemporaneous (i.e., same surgery) vs staged implantation of the HVAD as a BiVAD were compared. RESULTS: From 2011 to 2017, 46 patients received durable BiVADs and had the following characteristics: median age, 46 years (interquartile range [IQR], 19-67 years), non-ischemic cardiomyopathy (80%), bridge to transplant (83%), Interagency Registry for Mechanically Assisted Circulatory Support Profile 1 or 2 (92%), use of temporary circulatory support (37%), right atrial pressure 19 mm Hg (IQR, 14-23 mm Hg), and cardiac index of 1.6 liters/min/m2 (IQR, 1.2-2.1 liters/min/m2). Operative mortality was 33%. Equal numbers of patients received a right atrial or right ventricular implant. Contemporaneous BiVAD implantation occurred in 31 patients (67%), and compared with 15 patients (33%) with staged implants, these patients had a shorter intensive care unit length of stay of 12 days (IQR, 7-23 days) vs 42 days (IQR, 28-48 days, p = 0.035) and were more likely to be discharged from the hospital on BiVAD support (61% vs 27%, p = 0.04). RVAD thrombosis developed in 17 patients (37%). Patients with contemporaneous BiVAD implants had a 1-year survival of 74% compared with 40% in staged BiVAD patients (p = 0.11). CONCLUSIONS: Patients receiving durable BiVADs represent a critically ill patient population with severe biventricular failure who have high operative mortality and RVAD thrombosis rates. The 1-year survival for patients receiving contemporaneous BiVADs in experienced centers mirrors other contemporary durable biventricular support strategies.


Asunto(s)
Diseño de Equipo , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Falla de Prótesis , Adulto , Anciano , Enfermedad Crítica , Femenino , Insuficiencia Cardíaca/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Tasa de Supervivencia , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA