Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Biomech Eng ; 144(8)2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35044448

RESUMEN

The mechanisms underlying chronic pain development following musculoskeletal trauma are complex and multifactorial. In their search, some researchers are turning to the subchondral bone as a potential contributor to pain due to its vascularity, using a depth-specific imaging technique. However, this technique has been mainly used in the knee. We propose the use of a quantitative computed tomography (QCT) depth-specific analysis to measure subchondral bone following wrist trauma. Ten participants (n = 5 post-trauma; n = 5 healthy) underwent bilateral computed tomography scans of their wrist accompanied by a calibration phantom with known densities. Average subchondral volumetric bone mineral density (vBMD) was studied at three depths from the subchondral surface (0-2.5, 2.5-5, 5-7.5 mm) according to radial articular surface contact in both wrists of each participant. Percentage differences and Cohen's d effect sizes were calculated to analyze bilateral vBMD and vBMD differences between groups. This image-based tool demonstrated subject-specific, depth-specific, and joint-specific measures of vBMD within the wrist. This methodology highlighted the differences between depth-specific vBMD in healthy people and people who have experienced wrist trauma. Overall, the healthy cohort demonstrated higher vBMD across all three depths and both articular surfaces. This imaging technique further distinguished between subchondral cortical and trabecular bones, wherein clinical implications can be drawn from these distinctions in future work. Our study therefore supports the utility of a QCT imaging technique in detecting differences in depth-specific vBMD in the wrist.


Asunto(s)
Densidad Ósea , Muñeca , Hueso Esponjoso , Humanos , Dolor , Tomografía Computarizada por Rayos X/métodos , Muñeca/diagnóstico por imagen
2.
J Shoulder Elbow Surg ; 30(12): 2824-2831, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34216785

RESUMEN

BACKGROUND: The coronoid process is an important stabilizer of the elbow, and its anatomy has been extensively studied. However, data documenting the relationship of the coronoid relative to the radial head (RH) are limited. The latter is a good landmark for the surgeon when débriding or reconstructing the coronoid. This imaging-based study quantified the anatomic relationship between the coronoid and the proximal radius and ulna. METHODS: We investigated 80 cadaveric upper extremities (18 paired elbows) by 3-dimensional digital analysis of computed tomography data. After construction of a standardized coordinate system, the relationships between the coronoid, the anterior-most point of the RH, the deepest point of the articular surface of the RH, the top of the lesser sigmoid notch, and the deepest point of the guiding ridge of the trochlear notch were analyzed. RESULTS: The mean height of the tip of the coronoid was 36 ± 4 mm (range, 26-43 mm). The mean height of the anterior-most point of the RH was 40 ± 4 mm (range, 28-47 mm). The mean distance between the tip of the coronoid and the anterior-most point of the RH was 4.5 ± 1 mm (range, 2-10 mm). For paired elbows, the heights of the tip of the coronoid and the anterior-most point of the RH were similar between sides. CONCLUSION: This study described the relationship between the coronoid and RH. This information should prove useful when reconstructing a coronoid from a medial approach in the case of an intact RH. The difference in radiographic height between the tip of the coronoid and anterior RH in the normal elbow averages 5 mm. However, when we account for the normal cartilage thickness of the RH and coronoid, a 3- to 6-mm difference in height would be seen at surgery depending on whether the cartilage of the coronoid process is intact or removed. The distance between the tip of the coronoid and the anterior-most point of the RH is similar to the size of shavers used when débriding osteophytes during arthroscopy.


Asunto(s)
Articulación del Codo , Fracturas del Cúbito , Articulación del Codo/diagnóstico por imagen , Articulación del Codo/cirugía , Humanos , Radio (Anatomía)/diagnóstico por imagen , Radio (Anatomía)/cirugía , Tomografía Computarizada por Rayos X , Cúbito/diagnóstico por imagen , Cúbito/cirugía
3.
J Shoulder Elbow Surg ; 30(6): 1282-1287, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33045331

RESUMEN

BACKGROUND: The coronoid process plays a vital role in preserving elbow stability. In cases of acute or chronic deficiency of the coronoid process, reconstruction is warranted to restore stability and to avoid early joint degeneration. The distal clavicle might be a useful osteochondral autograft for coronoid reconstruction with low donor-site morbidity. This study evaluated the fitting accuracy of the distal clavicle as an autograft for coronoid process reconstruction. METHODS: One hundred upper-extremity computed tomography scans of 85 body donors were available for this study (mean age, 69 ± 17 years; 46 male and 39 female donors; 15 bilateral specimens). Standardized 40% transverse defects of the coronoid process were digitally created; the distal clavicles were digitally harvested and placed onto the defects by a best-fit technique in 2 different orientations using commercially available software: (1) with the superior aspect of the articular surface of the graft oriented toward the coronoid tip and (2) with the inferior aspect of the articular surface of the graft oriented toward the coronoid tip. The fitting accuracy of the grafts to the native coronoid process was evaluated from lateral to medial using custom code. RESULTS: Regardless of the orientation of the graft, the distal clavicle provided a good fit in the central portion of the coronoid process. In the lateral and medial aspects of the defect, however, the fitting accuracy of the graft declined significantly (P ≤ .044). No significant differences were observed between ipsilateral and contralateral grafts (P ≥ .199). The intrarater reliability was excellent. CONCLUSION: The results of this study suggest that a distal clavicle autograft may be suitable to replace a transverse defect of the coronoid process; however, it may not fully reconstruct the anteromedial and anterolateral aspects of the coronoid.


Asunto(s)
Articulación del Codo , Inestabilidad de la Articulación , Anciano , Autoinjertos , Trasplante Óseo , Clavícula/diagnóstico por imagen , Clavícula/cirugía , Simulación por Computador , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados
4.
J Shoulder Elbow Surg ; 29(8): 1615-1620, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32197806

RESUMEN

BACKGROUND: The reconstructive options for instability-related anterior glenoid bone loss include iliac crest autograft, allograft, or coracoid transfer. The use of distal clavicle autograft (DCG) has also been described. The purpose of this imaging and cadaveric study was to examine the dimensions, morphology, and bone density of the DCG and compare it with the Latarjet procedure. METHODS: We used 49 computed tomography scans from patients with anterior glenoid bone loss to measure the distal clavicle dimensions and bone density. Four glenoid reconstructions were simulated to compare techniques: DCG inferior surface toward glenoid (DCG inferior), DCG superior, classic Latarjet, and congruent-arc Latarjet. In addition, the morphology of the DCG was assessed on computed tomography and confirmed in 27 cadavers. RESULTS: The mean width of the DCG (11 mm) was significantly greater (P < .001) than that of the classic Latarjet orientation (9 mm) but less (P = .002) than that of the congruent-arc orientation (12 mm). The DCG had a lower bone density than the coracoid (P < .001). The mean articular surface area of the DCG-inferior orientation was 208 mm2, which was greater (P = .013) than that of the DCG-superior orientation (195 mm2) and not significantly different (P = .44) than that of the classic Latarjet orientation (214 mm2). The surface area of the congruent-arc orientation was greater (285 mm2, P < .001) than that of all other graft orientations. The DCG-inferior orientation was able to reconstruct 22% of the glenoid articular surface; DCG-superior orientation, 21%; classic Latarjet orientation, 23%; and congruent-arc orientation, 30%. Three DCG morphologies were identified: square (34%), trapezoidal (53%), and rounded (13%). CONCLUSIONS: The distal clavicle osteoarticular graft was able to reconstruct 22% of the glenoid face. Three morphologies of the distal clavicle were identified, with the square and trapezoidal morphologies most amenable for glenoid reconstruction.


Asunto(s)
Enfermedades Óseas Metabólicas/cirugía , Trasplante Óseo/métodos , Clavícula/trasplante , Inestabilidad de la Articulación/cirugía , Escápula/cirugía , Adolescente , Adulto , Densidad Ósea , Enfermedades Óseas Metabólicas/etiología , Cadáver , Femenino , Humanos , Masculino , Persona de Mediana Edad , Articulación del Hombro/cirugía , Tomografía Computarizada por Rayos X , Trasplante Autólogo , Trasplante Homólogo , Adulto Joven
5.
J Shoulder Elbow Surg ; 29(5): 1071-1082, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32147336

RESUMEN

BACKGROUND: Joint registries provide invaluable data on primary arthroplasties with revision as the endpoint; however, the revision outcomes are often excluded. Therefore, a PROSPERO registered review (CRD42015032531) of all revision studies in North America and Europe was conducted to evaluate demographics, etiologies and indications, implant manufacturer, and complications by geographic region. METHODS: The MEDLINE, EMBASE, and CENTRAL databases were searched for revision arthroplasty clinical studies with a minimum mean 24-month follow-up. There were no language exclusions. Articles published in German, French, and Italian were reviewed by research personnel proficient in each language. RESULTS: The mean age at revision was 66 ± 5 years (male = 759, female = 1123). The male-female ratio in North American and Europeans studies was 43:57 and 34:66, respectively. The most common etiology for primary surgery in both regions was osteoarthritis or glenoid arthrosis (38%). The most common revision indication overall was rotator cuff tear, deficiency, or arthropathy (26%). The most common implant type used in revisions was a reverse shoulder arthroplasty (54%). The complication rate for all revisions was 17%. There were a total of 465 complications, and of those, 74% lead to a reoperation. CONCLUSION: Generally, shoulder arthroplasties are designed to last 10-15 years; however, revisions are being performed at a mean 3.9 years from the primary procedure, based on the published studies included in this systematic review. Additionally, of the complications, a large number (74%) went on to a reoperation. Further insight into the reasons for early revisions and standardized reporting metrics and data collection on revisions is needed.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Complicaciones Posoperatorias/etiología , Reoperación , Anciano , Artroplastía de Reemplazo de Hombro/efectos adversos , Europa (Continente) , Femenino , Humanos , Artropatías/cirugía , Masculino , Persona de Mediana Edad , América del Norte , Reoperación/efectos adversos , Lesiones del Manguito de los Rotadores/cirugía , Resultado del Tratamiento
6.
J Shoulder Elbow Surg ; 29(7): 1460-1469, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32061510

RESUMEN

BACKGROUND: The purpose of this study was 2-fold: (1) to quantify type E2 bone loss orientation and its association with rotator cuff fatty infiltration and (2) to examine reverse baseplate designs used to manage type E2 glenoids. METHODS: Computed tomography scans of 40 patients with type E2 glenoids were examined for pathoanatomic features and erosion orientation. The rotator cuff fatty infiltration grade was compared with the erosion orientation angle. To compare reconstructive options in light of the pathoanatomic findings, virtual implantation of 4 glenoid baseplate designs (standard, half wedge, full wedge, and patient-matched) was conducted to determine the volume of bone removal for seating and impingement-free range of motion. RESULTS: The mean type E2 erosion orientation angle was 47° ± 17° from the 0° superoinferior glenoid axis, resulting in the average erosion being located in the posterosuperior quadrant directed toward the 10:30 clock-face position. The type E2 neoglenoid, on average, involved 67% of the total glenoid surface (total surface area, 946 ± 209 mm2; neoglenoid surface area, 636 ± 247 mm2). The patient-matched baseplate design resulted in significantly (P ≤ .01) less bone removal (200 ± 297 mm3) for implantation, followed by the full-wedge design (1228 ± 753 mm3), half-wedge design (1763 ± 969 mm3), and standard (non-augmented) design (4009 ± 1210 mm3). We noted a marked difference in erosion orientation toward a more superior direction as the subscapularis fatty infiltration grade increased from grade 3 to grade 4 (P < .001). CONCLUSION: The average type E2 erosion orientation was directed toward the 10:30 clock-face position in the posterosuperior glenoid quadrant. This orientation resulted in the patient-matched glenoid augmentation requiring the least amount of bone removal for seating, followed by the full-wedge, half-wedge, and standard designs. Implant selection also substantially affected computationally derived range of motion in external rotation, flexion, extension, and adduction.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Enfermedades Óseas Metabólicas/diagnóstico por imagen , Enfermedades Óseas Metabólicas/etiología , Lesiones del Manguito de los Rotadores/complicaciones , Prótesis de Hombro , Anciano , Anciano de 80 o más Años , Enfermedades Óseas Metabólicas/cirugía , Femenino , Cavidad Glenoidea/cirugía , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/cirugía , Escápula/cirugía , Articulación del Hombro/cirugía , Tomografía Computarizada por Rayos X
7.
J Shoulder Elbow Surg ; 29(1): 167-174, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31473132

RESUMEN

BACKGROUND: Little is known about the cortical-like and cancellous bone density variations in superiorly eroded glenoids due to cuff tear arthropathy. The purpose of this study was to analyze regional bone density in type E2 glenoids. METHODS: Clinical shoulder computed tomography scans were obtained from 32 patients with a type E2 superior erosion (10 men and 22 women; mean age, 73 years). Measurement regions were organized into quadrants (superior, inferior, anterior, and posterior) and depth regions. The depth regions were incremented by 2 mm from 0 to 10 mm. A repeated-measures multiple analysis of variance was performed to assess differences and interactions between mean densities (cortical-like and cancellous bone) in each depth, in each quadrant, and between sexes. RESULTS: The lowest cancellous bone density was found in the inferior glenoid quadrant compared with all other quadrants (307 ± 50 Hounsfield units [HU], P < .001). At the glenoid surface, the superior quadrant contained the highest mean density for cortical-like bone (895 ± 97 HU); this differed significantly from the posterior, anterior, and inferior quadrants (P ≤ .033). As for depth of measurement, cortical-like bone was most dense at the glenoid surface (0-2 mm, 892 ± 91 HU), and density decreased significantly at depths greater than 2 mm (P ≤ .019). CONCLUSION: In patients with type E2 glenoids due to cuff tear arthropathy, the densest bone was found in the superior quadrant in the area of erosion. The inferior quadrant, which tends to be unloaded as the humeral head migrates superiorly, had the lowest density bone. In addition, the best-quality bone was located at the glenoid surface as compared with deeper in the vault.


Asunto(s)
Densidad Ósea , Hueso Esponjoso/diagnóstico por imagen , Cavidad Glenoidea/diagnóstico por imagen , Artropatía por Desgarro del Manguito de los Rotadores/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Femenino , Cavidad Glenoidea/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Artropatía por Desgarro del Manguito de los Rotadores/fisiopatología , Articulación del Hombro/diagnóstico por imagen , Tomografía Computarizada por Rayos X
8.
J Hand Surg Am ; 44(9): 794.e1-794.e8, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30502012

RESUMEN

PURPOSE: The anatomy of the radial head and capitellum has been extensively studied; however, the anatomy of the radial notch of the ulna (RNU) has received little attention. This imaging-based anatomic study characterizes the morphology of the RNU. METHODS: Ninety-eight cadaveric arms (57 male, 72 ± 14 y) were imaged with computed tomography, and 3-dimensional reconstructions of the proximal ulna were constructed. The anteroposterior and proximal-distal dimensions of the RNU as well as the radius of curvature at standardized levels were measured in 2-mm increments. The orientation of the RNU was also determined. RESULTS: The proximal-distal and anteroposterior dimensions of the RNU were 12 ± 2 mm (range, 7-16 mm) and 18 ± 3 mm (range, 12-24 mm), respectively. The average radius of curvature of the RNU was 15 ± 0 mm (range, 15-16 mm). The radius of curvature did not change significantly when comparing the proximal and distal aspect of the RNU. The RNU was rotated 33° ± 2° (range, 31° to 38°) externally relative to the transverse plane of the ulna. The average depth of the RNU at its deepest point was 2.2 ± 0.4 mm (range, 1.5-2.7 mm). The depth decreased from proximal to distal, being most shallow distally. The depth changed by an increase of the radius of curvature, as well as by rotation in the frontal plane. CONCLUSIONS: The RNU anatomy was variable, generally extending laterally from proximal to distal. This suggests that a radial head implant should taper from proximal to distal to optimize contact at the RNU. CLINICAL RELEVANCE: The present study investigates the detailed anatomy of the radial notch of the ulna using computed tomography scans. The data might help improve the design of prosthetic components.


Asunto(s)
Radio (Anatomía)/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Cúbito/diagnóstico por imagen , Anciano , Puntos Anatómicos de Referencia , Cadáver , Femenino , Humanos , Imagenología Tridimensional , Masculino , Radio (Anatomía)/anatomía & histología , Cúbito/anatomía & histología
9.
J Shoulder Elbow Surg ; 28(9): 1801-1808, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31043349

RESUMEN

BACKGROUND: The Walch type B glenoid has the hallmark features of retroversion, joint subluxation, and bony erosion. Although the type B glenoid has been well described, the morphology of the corresponding type B humerus is poorly understood. As such, the aim of this imaging-based anthropometric study was to investigate humeral torsion in Walch type B shoulders. METHODS: Three-dimensional models of the full-length humerus were generated from computed tomography data for the Walch type B group (n = 59) and for a control group of normal nonarthritic shoulders (n = 59). An anatomic humeral head-neck plane was created and used to determine humeral torsion relative to the epicondylar axis. Measurements were repeated, and intraclass correlation coefficients were calculated. RESULTS: The type B humeri had significantly (P < .001) less retrotorsion (14° ± 9°) than the control group (36° ± 12°) relative to the epicondylar axis. Male and female individuals within the control group showed statistically significant differences in humeral torsion (P = .043), which were not found in the type B group. Inter-rater reliability showed excellent agreement for humeral torsion (intraclass correlation coefficient, 0.962). A subgroup analysis between Walch type B2 and B3 shoulders showed no significant differences in any of the humeral or glenoid parameters. CONCLUSION: The Walch type B humerus has significantly less retrotorsion than non-osteoarthritic shoulders. At present, it is unknown whether the altered humeral retrotorsion is a cause or effect of the type B glenoid. In addition, it is unknown whether surgeons should be reconstructing type B2 humeral component version to pathologic torsion or to nonpathologic population means to optimize arthroplasty survivorship.


Asunto(s)
Húmero/patología , Osteoartritis/patología , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Antropometría , Estudios de Casos y Controles , Femenino , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/patología , Humanos , Húmero/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Modelos Anatómicos , Variaciones Dependientes del Observador , Osteoartritis/diagnóstico por imagen , Reproducibilidad de los Resultados , Factores Sexuales , Articulación del Hombro/diagnóstico por imagen
10.
J Shoulder Elbow Surg ; 28(4): e117-e124, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30713058

RESUMEN

BACKGROUND: The integrity of the coronoid process is critical to maintaining elbow stability. Unreconstructible fractures and chronic coronoid deficiency are challenging clinical problems with no clear solution. The purposes of this study were to investigate the shape match of the ipsilateral and contralateral olecranon tips as graft options and to determine the influence of the osteotomy angle on fitment. METHODS: Nineteen paired cadaveric elbow joints were investigated by 3-dimensional digital analysis of computed tomography DICOM (Digital Imaging and Communications in Medicine) data. After construction of an ulnar coordinate system, the ipsilateral and contralateral olecranon tips were digitally harvested at 10°, 20°, 30°, 40°, 50°, and 60° osteotomy angles. In an overlay analysis, we compared the shape match of the ipsilateral and contralateral grafts and the different angles. RESULTS: The ipsilateral grafts showed an average mismatch of 1.8 mm (standard deviation, 1.38 mm), whereas the contralateral grafts had a significantly lower (P < .001) mean mismatch of 1.3 mm (standard deviation, 0.95 mm). The 50° osteotomy plane showed the best shape match in comparison with the native coronoid-in both the ipsilateral and contralateral grafts. Evaluation of the intraclass correlation coefficient was calculated at r = 0.944, showing high repeatability of the measurements. CONCLUSIONS: The contralateral olecranon tip graft showed significantly better shape matching to the native coronoid than the ipsilateral olecranon graft. Specifically, the contralateral graft more closely matched the biomechanically critical anteromedial coronoid facet. Finally, both the contralateral and ipsilateral olecranon grafts had better shape matching with the native coronoid when osteotomy was performed at higher angles, specifically 50°.


Asunto(s)
Olécranon/anatomía & histología , Fracturas del Cúbito/cirugía , Anciano , Anciano de 80 o más Años , Trasplante Óseo , Cadáver , Epífisis/lesiones , Epífisis/cirugía , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Olécranon/trasplante , Osteotomía , Procedimientos de Cirugía Plástica , Tomografía Computarizada por Rayos X , Cúbito/cirugía
11.
J Biomech Eng ; 140(9)2018 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-29801170

RESUMEN

Quantitative computed tomography (qCT) relies on calibrated bone mineral density data. If a calibration phantom is absent from the CT scan, post hoc calibration becomes necessary. Scanning a calibration phantom after-the-fact and applying that calibration to uncalibrated scans has been used previously. Alternatively, the estimated density is known to vary with CT settings, suggesting that it may be possible to predict the calibration terms using CT settings. This study compares a novel CT setting regression method for post hoc calibration to standard and post hoc phantom-only calibrations. Five cadaveric upper limbs were scanned at 11 combinations of peak tube voltage and current (80-140 kV and 100-300 mA) with two calibration phantoms. Density calibrations were performed for the cadaver scans, and scans of the phantoms alone. Stepwise linear regression determined if the calibration equation terms were predictable using peak tube voltage and current. Peak tube voltage, but not current, was significantly correlated with regression calibration terms. Calibration equation slope was significantly related to the type of phantom (p < 0.001), calibration method (p = 0.026), and peak tube voltage (p < 0.001), but not current (p = 1.000). The calibration equation vertical intercept was significantly related to the type of phantom (p < 0.001), and peak tube voltage (p = 0.006), but not calibration method (p = 0.682), or current (p = 0.822). Accordingly, regression can correlate peak tube voltage with density calibration terms. Suggesting that, while standard qCT calibration is preferable, regression calibration may be an acceptable post hoc method when necessary.


Asunto(s)
Densidad Ósea , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/instrumentación , Anciano , Calibración , Humanos , Análisis de Regresión
12.
J Shoulder Elbow Surg ; 26(5): 909-914, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28089255

RESUMEN

BACKGROUND: The type B3 glenoid is an addition to the Walch classification. A potential etiologic theory is that it is a progression of the B2. It is characterized by uniconcavity, absent paleoglenoid, medialization, retroversion, and subluxation. The purpose of this study was to describe the morphology of B3 glenoids. METHODS: Fifty-two patients with B3 glenoids underwent 3-dimensional analysis of computed tomography data. Glenoid measurements (retroversion, inclination, medialization) and humeral head subluxation according to the scapular and glenoid planes were determined. The measured variables were compared between male and female patients. RESULTS: The mean B3 retroversion, inclination, and medialization were 24° ± 7°, 8° ± 6° superior, and 14 ± 4 mm, respectively. The mean posterior subluxation was 80% ± 8% and 54% ± 6% according to the scapular and glenoid planes, respectively. There were no differences in B3 characteristics between sexes (P > .05). A significant correlation existed between glenoid retroversion and humeral head subluxation relative to the scapular plane, with every 1° increase in retroversion translating to a 1% increase in subluxation (P < .001). In contrast, when referencing the glenoid plane, the humeral head remained concentric to the erosion. CONCLUSIONS: The B3 is uniconcave and retroverted. As glenoid retroversion increases, posterior humeral head subluxation significantly increases as referenced to the scapular plane; however, when referenced to the glenoid plane, the head remains concentric to the erosion. This appearance of "concentricity" is acquired secondary to the wear pattern, creating a uniconcave glenoid. Therefore, surgeons should be aware that the visualized concentricity is a product of the erosion pattern and thus may conceal a greater amount of subluxation potential.


Asunto(s)
Osteoartritis/diagnóstico por imagen , Articulación del Hombro/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Luxación del Hombro/diagnóstico por imagen , Tomografía Computarizada por Rayos X
13.
J Shoulder Elbow Surg ; 25(7): 1064-8, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26895600

RESUMEN

BACKGROUND: Posterior glenoid erosion is thought to be initiated by humeral head subluxation. However, it is unknown whether subluxation is entirely caused by soft-tissue instability and unbalanced muscle activity or whether osseous morphology is a contributing factor. We hypothesized that patients with posterior erosion may exhibit premorbid glenoid morphology that is inherently retroverted and inferiorly inclined compared with age-matched normal glenoids. METHODS: This study examined 80 scapulae, evenly distributed between 2 groups: osteoarthritic with type B2 glenoids and age-matched normal glenoids. From 3-dimensional computed tomography reconstructions, version and inclination were measured from the anterior paleoglenoid region of the B2 glenoids, which is representative of the premorbid glenoid, and compared with measurements obtained from similar regions in the normal cohort. RESULTS: The anterior paleoglenoid region of B2 glenoids was significantly (P < .001) more retroverted (-14° ± 6°) compared with similar regions in nonarthritic normal glenoids (-5° ± 5°). There were no significant differences (P = .166) in the glenoid inclination angle between type B2 glenoids (0° ± 6°) and nonarthritic normal glenoids (2° ± 5°). Negative values represent retroverted and inferiorly inclined glenoids. DISCUSSION: Understanding premorbid glenoid morphologic variations may provide insight into the pathoanatomy of humeral head subluxation, osteoarthritis, and posterior glenoid erosion. The results of this study indicate that patients with type B2 osteoarthritic glenoids have significantly greater premorbid glenoid retroversion compared with nonarthritic normal glenoids, suggesting that this premorbid morphologic variation may be one contributing factor to posterior erosion.


Asunto(s)
Cavidad Glenoidea/diagnóstico por imagen , Osteoartritis/diagnóstico por imagen , Articulación del Hombro/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
14.
J Shoulder Elbow Surg ; 25(3): 502-9, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26597658

RESUMEN

BACKGROUND: The purpose of this study was to evaluate and to compare the size and morphologic patterns among normal and osteoarthritic (OA) humeral heads. METHODS: This comparative anatomic imaging study evaluated 150 humeral heads that were separated into 3 cohorts: normal, OA with symmetric glenoid erosion, and OA with asymmetric (type B2) glenoid erosion. Three-dimensional models were created of the humeral head from computed tomography data, and point coordinates were extracted for evaluation. Parameters measured were diameter (sphere fit and circle fit), chord distance (superoinferior and anteroposterior), and humeral head height. RESULTS: The sphere-fit diameter of the humeral head for the entire OA cohort (100 patients; mean diameter, 59 ± 9 mm) was significantly greater (P < .001) than that of the normal cohort (50 patients; mean diameter, 49 ± 5 mm). Similarly, the humeral head circle-fit diameters in the superoinferior and anteroposterior planes were significantly greater (P < .001) in the combined OA cohorts (59 ± 9 mm and 56 ± 10 mm, respectively) compared with the normal cohort (51 ± 5 mm and 47 ± 5 mm, respectively). However, there were no significant differences (P ≥ .099) between the symmetric and asymmetric OA cohorts in sphere-fit or circle-fit diameters. The mean values of humeral head heights were not significantly different (P = .382) between cohorts, 19 ± 2 mm, 18 ± 2 mm, and 18 ± 2 mm for the normal, symmetric, and asymmetric cohorts, respectively. DISCUSSION: Although OA humeral head morphology varies significantly from normal, it does not vary as a function of the Walch classification between symmetric and asymmetric glenoids. Understanding of the morphologic variability of the pathologic humeral head may provide insight into the pathoanatomy of osteoarthritis and the development of various erosion patterns.


Asunto(s)
Cabeza Humeral/anatomía & histología , Cabeza Humeral/diagnóstico por imagen , Osteoartritis/diagnóstico por imagen , Osteoartritis/patología , Articulación del Hombro/anatomía & histología , Articulación del Hombro/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Cabeza Humeral/patología , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Modelos Anatómicos , Escápula/diagnóstico por imagen , Escápula/patología , Articulación del Hombro/patología , Tomografía Computarizada por Rayos X
15.
J Shoulder Elbow Surg ; 24(8): 1218-26, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25648971

RESUMEN

BACKGROUND: The purpose of this computational modeling study was to compare the volume of glenoid bone removal required to implant 3 augmented component designs for management of B2 erosions. In addition, we assessed bone quality of the supporting bone directly beneath the implants by measuring bone density and porosity. METHODS: Three augmented component designs­full-wedge, posterior-wedge, and posterior-step­were studied by virtual implantation in a cohort of 16 patients with B2 glenoids. B2 retroversion was corrected to 0° and 10°. The outcome variables were the volume of glenoid bone removal required for implantation and the density and porosity of the bone immediately beneath the implant. RESULTS: Implant design had a significant effect on the volume of bone removal (P < .001). When correcting to 0°, the posterior-wedge implant removed less bone than the posterior-step (P < .001) and the full-wedge (P = .004). At 10° retroversion, the posterior-wedge removed less bone (P = .029) than the posterior-step but was no different than the full-wedge (P = .143). The residual glenoid bone density with the posterior-wedge was significantly greater than with the posterior-step (P = .048), with no other significant differences (P > .05). Residual glenoid bone porosity was not significantly different between implants (P > .262). CONCLUSIONS: Augmented components can provide a bone-preserving option for B2 glenoid management. Substantial variations in the volume of bone removal and the quality of the remaining glenoid bone were found between 3 different designs of augmented implants. Simulations with the posterior-wedge implant resulted in substantially less glenoid bone removal, with the remaining supporting bone being of better quality.


Asunto(s)
Artroplastia de Reemplazo/métodos , Simulación por Computador , Osteoartritis/cirugía , Prótesis e Implantes , Articulación del Hombro/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Densidad Ósea , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis/diagnóstico , Diseño de Prótesis , Escápula/patología , Escápula/cirugía , Articulación del Hombro/patología
16.
J Shoulder Elbow Surg ; 24(3): 425-32, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25306495

RESUMEN

BACKGROUND: Accurate characterization of regional variations in bone density in symmetric and asymmetric (B2) glenoid erosion patterns can assist with surgical planning, reaming, and component implantation. The purpose of this study was to characterize regional bone density and porosity in symmetric and asymmetric (B2) osteoarthritic glenoids. METHODS: Symmetric (n = 25) and asymmetric (B2) (n = 25) erosion patterns were compared by computed tomography-based imaging software. An orthogonal coordinate system separated each glenoid into quadrants. In addition, a linear best-fit line defined the line-of-erosion between the paleoglenoid and neoglenoid in the asymmetric cohort. All glenoids were further divided into volumes at depths of 0 to 2.5 mm and 2.5 to 5 mm. Average bone density was measured in Hounsfield units. Bone voids or cysts were included to quantify regional porosity as the fraction of void volume to total glenoid volume. RESULTS: For the symmetric cohort, there were no significant differences in bone density between quadrants at either depth (P ≥ .089). For the asymmetric cohort, bone density was significantly higher in the posterior quadrants compared with the anterior quadrants (P < .001), especially posteroinferiorly (P ≤ .007) at both depths. In addition, the neoglenoid had significantly higher density and lower void fraction compared with the paleoglenoid (P < .001). There were also significant differences in void fraction between quadrants for both cohorts, at both depths (P ≤ .004). CONCLUSIONS: This study demonstrates that osteoarthritic glenoids with symmetric erosion have uniform subarticular bone density. However, asymmetric (B2) erosion patterns have potentially important regional variations in bone density and porosity, with the densest bone with the least porosity found posteroinferiorly or in the neoglenoid region.


Asunto(s)
Densidad Ósea , Osteoartritis/diagnóstico por imagen , Escápula/diagnóstico por imagen , Articulación del Hombro/diagnóstico por imagen , Anciano , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis/fisiopatología , Porosidad , Falla de Prótesis , Escápula/fisiopatología , Articulación del Hombro/fisiopatología , Tomografía Computarizada por Rayos X
17.
J Shoulder Elbow Surg ; 24(4): 503-10, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25440510

RESUMEN

BACKGROUND: The purpose of this computed tomography-based study was to quantify erosions in B2 glenoids. We hypothesized that erosions do not occur symmetrically and that they have a predictable orientation. METHODS: This study evaluated 55 type B2 glenoid cases. Computed tomography data were used to create three-dimensional reconstructions, and point coordinates were extracted from each reconstruction for morphologic analysis of the osteoarthritic glenoid and humerus. RESULTS: There was a significant difference between the mean orientation angle (28° ± 11°) of the posterior glenoid line of erosion and the superoinferior axis (P < .001), which resulted in the average erosion being directed toward the 8-o'clock position. On average, the erosion started 1.6 ± 3.4 mm posterior to the glenoid center point. In 35% of B2 cases, the line of erosion was curved. The mean surface area was 763 ± 296 mm(2) for the neoglenoid and 957 ± 276 mm(2) for the paleoglenoid, indicating that the neoglenoid occupied 44% ± 12% of the total glenoid area. In this cohort, the mean radius of the humeral head neoarticulation was 32 ± 6 mm, the neoglenoid radius was 37 ± 8 mm, and the paleoglenoid radius was 34 ± 7 mm. The radius of the humeral head was significantly less than that of the neoglenoid (P < .001) and the paleoglenoid (P = .009). In addition, the radius of the neoglenoid was significantly greater than the radius of the paleoglenoid (P = .012). DISCUSSION: Type B2 glenoids have a predictable wear pattern, which is not axisymmetric to the glenoid superoinferior axis. In addition, the identified anatomic characteristics of B2 erosions will aid surgeons in the operative management of bone loss and may assist manufacturers in the design of augmented components.


Asunto(s)
Cavidad Glenoidea/diagnóstico por imagen , Imagenología Tridimensional , Osteoartritis/diagnóstico por imagen , Articulación del Hombro/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Cabeza Humeral/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados
18.
J Biomech ; 161: 111849, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37931557

RESUMEN

Bone tissue is influenced by its mechanical environment and adapts in response to its mechanical load. This is supported by studies analyzing bone adaptation in the knee and hip. Changes to the bone have also been found to precede cartilage degeneration in diseases such as osteoarthritis (OA). Our objective was to demonstrate the relationship between joint contact and bone density in the wrists of healthy adults. Static CT scans with a calibration phantom were taken to obtain measures of bone mineral density (vBMD) in 3 normalized depths; 0 - 2.5, 2.5 - 5, and 5 - 7.5 mm. Participants underwent a four-dimensional CT scan (4DCT) while performing maximum wrist extension to maximum wrist flexion. 3D bone models of the distal radius, scaphoid, and lunate were made, and analyzed vBMD and joint contact area (JCA) in the radiolunate (RL) and radioscaphoid (RS) joints separately. Correlation coefficients were calculated where vBMD was the dependent variable, and kinematic JCA throughout every 10 degrees of motion were the independent variables. Statistically significant independent variables associated with vBMD were assessed using a regression model and were entered in steps; (1) significant correlations, (2) sex, and (3) age.An increase in vBMD was significantly, positively associated with an increase in JCa. Notably, in the deeper regions (5 - 7.5 mm) of the radius that is primarily composed of trabecular bone. Sex contributed to the variance in vBMD, while age did not. Subchondral bone changes are influenced by wrist position, demonstrating that the wrist serves to bear load similar to the knee and hip.


Asunto(s)
Osteoartritis , Hueso Escafoides , Adulto , Humanos , Muñeca , Articulación de la Muñeca/diagnóstico por imagen , Articulación de la Muñeca/fisiología , Hueso Escafoides/fisiología , Osteoartritis/diagnóstico por imagen , Tomografía Computarizada Cuatridimensional
19.
J Exp Orthop ; 10(1): 1, 2023 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-36607513

RESUMEN

PURPOSE: This study aimed to assess the accuracy and reproducibility of four common segmentation techniques measuring subchondral bone cyst volume in clinical-CT scans of glenohumeral OA patients. METHODS: Ten humeral head osteotomies collected from cystic OA patients, having undergone total shoulder arthroplasty, were scanned within a micro-CT scanner, and corresponding preoperative clinical-CT scans were gathered. Cyst volumes were measured manually in micro-CT and served as a reference standard (n = 13). Respective cyst volumes were measured on the clinical-CT scans by two independent graders using four segmentation techniques: Qualitative, Edge Detection, Region Growing, and Thresholding. Cyst volume measured in micro-CT was compared to the different clinical-CT techniques using linear regression and Bland-Altman analysis. Reproducibility of each technique was assessed using intraclass correlation coefficient (ICC). RESULTS: Each technique outputted lower volumes on average than the reference standard (-0.24 to -3.99 mm3). All linear regression slopes and intercepts were not significantly different than 1 and 0, respectively (p < 0.05). Cyst volumes measured using Qualitative and Edge Detection techniques had the highest overall agreement with reference micro-CT volumes (mean discrepancy: 0.24, 0.92 mm3). These techniques showed good to excellent reproducibility between graders. CONCLUSIONS: Qualitative and Edge Detection techniques were found to accurately and reproducibly measure subchondral cyst volume in clinical-CT. These findings provide evidence that clinical-CT may accurately gauge glenohumeral cystic presence, which may be useful for disease monitoring and preoperative planning. LEVEL OF EVIDENCE: Retrospective cohort Level 3 study.

20.
Comput Methods Programs Biomed ; 225: 107051, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35939979

RESUMEN

BACKGROUND: Image-based finite element (FE) modeling of bone is a non-invasive method to estimate bone stiffness and strength. High-resolution imaging data as input allows for inclusion of bone microarchitecture but results in large amounts of data unsuitable for traditional FE solvers. Bone-specific mesh-free solvers have been developed over the past 20 years to improve on memory efficiency in simulated bone loading applications. The objective of this study was to provide linear performance benchmarking for a bone-specific, mesh-free solver (FAIM) using µCT and HR-pQCT image data on Mac, Linux, and Windows operating systems using both single- and multi-thread CPU and GPU processing. METHODS: The focus is on the linear gradient-descent solver using standardized uniaxial loading of bone models from µCT, and first- and second-generation HR-pQCT scans of the radius and tibia. Convergence, speedup, memory, and batch performance tests were completed using CPUs and GPUs on three laboratory-based systems with Windows, Linux, and Mac operating systems. RESULTS: Although varying by system and model size, time-per-iteration was as low as 0.03 s when an HR-pQCT-based radius model (6.45 million DOF) was solved with 3 GPUs. Strong scaling was achieved with GPU and CPU parallel processing, with strong parallel efficiencies when models were solved using 3 GPUs or ≤ 10 CPU threads. Errors in force, strain energy density, and Von Mises stress were as low as 0.1% when a convergence tolerance of 10-3 or smaller was used. CONCLUSION: The results of this study indicate that to maximize computational efficiency and minimize model solution times using FAIM software under the standardized tested conditions using µCT, XCT1 and XCT2 HR-pQCT image data, convergence tolerance set to 10-4, and 10 threads or 2 GPUs are sufficient for efficient solution times. Less strict convergence tolerances will improve solution times but will introduce more error in the outcome measures.


Asunto(s)
Huesos , Radio (Anatomía) , Densidad Ósea , Huesos/diagnóstico por imagen , Análisis de Elementos Finitos , Tibia , Tomografía Computarizada por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA