Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39171406

RESUMEN

PURPOSE: Trochlear dysplasia is a major risk factor for recurrent patellar instability, reduced quality of life and osteoarthritis of the patellofemoral joint. Patellar instability in patients with trochlear dysplasia can be treated by trochleoplasty, usually in combination with medial patellofemoral ligament reconstruction (MPFL-R). An á la carte treatment algorithm, which also addresses patella alta, lateralisation of the tibial tuberosity and valgus or torsional malalignment when present has been standard in one clinic for treatment of patellar instability patients since 2009, based on the hypothesis that it results in optimal subjective and clinical outcome, normalisation of the lateral trochlea inclination (LTI) angle and a low rate of patellar redislocation. METHODS: This prospective study reports the 5-year results for consecutive patients with high-grade trochlea dysplasia operated according to the algorithm 2010-2017, evaluated preoperatively and 1, 2 and 5 years postoperatively. Clinical information on previous surgery and postoperative patellar stability, range-of-motion (ROM) and subsequent surgery were registered. Subjective outcome was evaluated by four patient-reported outcome measures (PROMs): Kujala, Lysholm, International Knee Documentation Committee and Knee injury and Osteoarthritis Outcome Score. The LTI angle was measured pre- and postoperatively on magnetic resonance imaging scans. RESULTS: There were 131 patients (87 females) with a median age of 22 years (range: 14-38). All had a trochleoplasty and an MPFL-R. Additional procedures (tibial tuberosity medialisation/distalisation and/or femoral/tibial osteotomy) were performed in 52%. All PROM scores improved from preoperatively to 1-year follow-up with further improvement at 2 and 5 years after surgery (p < 0.05). Three patients (2%) had a traumatic patellar dislocation 9, 12 and 24 months postoperatively and 38% underwent subsequent surgery (hardware removal, arthroscopically assisted brisement force, knee arthroscopy). A normalisation of the LTI angle (≥11°) was achieved in 76%. CONCLUSIONS: Treatment according to the à la carte algorithm for patients with patellar instability and high-grade trochlear dysplasia resulted in significant clinical and subjective improvement in all PROM scores and a very low redislocation rate (2%) 5 years after surgery. LEVEL OF EVIDENCE: Level II.

2.
Knee Surg Sports Traumatol Arthrosc ; 31(11): 4871-4877, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37573265

RESUMEN

PURPOSE: To present 1-year results after all paediatric anterior cruciate ligament (ACL) reconstructions in Denmark (5.9 M inhabitants) for the 10½ year period, 1 July 2011 to 31 December 2021. METHODS: All children who had an ACL reconstruction were enrolled. They were asked to complete Pedi-IKDC preoperatively and at 1-year follow-up. Independent observers performed pivot shift test and instrumented laxity assessment preoperatively and at 1-year follow-up. RESULTS: The median age of the 506 children (47.2% girls) was 14.3 years (9.3-15.9). The Pedi-IKDC score increased from preoperatively 61.6 ± 15.8 (mean ± SD) to 85.9 ± 13.0 at 1-year follow-up (p < 0.0001). There were concomitant injuries (to meniscus and/or cartilage) in 49.9%, but these children had preoperative and follow-up Pedi-IKDC scores similar to the scores for children with isolated injury to ACL (n. s.). Instrumented anterior laxity was 4.3 ± 1.4 (mean ± SD) mm preoperatively and 1.4 ± 1.4 mm at follow-up (p < 0.0001). Preoperatively, 3% had no pivot shift whilst this was the case for 68% postoperatively (p < 0.0001). Twenty-five children (5.6%) had 4 mm instrumented laxity or more relative to the unoperated knee at follow-up. Two patients (0.4%) had an operatively treated deep infection, three (0.5%) were operated on for reduced range of motion and two (0.4%) had a revision ACL reconstruction. CONCLUSION: ACL reconstruction resulted in a clinically meaningful increase in Pedi-IKDC, an improved instrumented stability, a reduction in the grade of pivot shift and the complication rate was low at 1-year follow-up. The risk of graft insufficiency at 1-year follow-up was the same as in an adult population. LEVEL OF EVIDENCE: II.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior , Femenino , Humanos , Adulto , Niño , Adolescente , Masculino , Estudios de Seguimiento , Lesiones del Ligamento Cruzado Anterior/cirugía , Articulación de la Rodilla/cirugía , Reconstrucción del Ligamento Cruzado Anterior/métodos , Dinamarca , Resultado del Tratamiento
3.
Orthopedics ; 25(1): 49-51, 2002 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11811242

RESUMEN

This study determined the accuracy of standard radiographs in observing radiolucency adjacent to the tibial component in total knee arthroplasty. A model of the proximal tibia was used. Plastic sleeves of different heights were glued under the tibial tray to imitate radiolucency. By tilting the x-ray tube 1degrees at a time, an investigation was performed to determine how many degrees it would take to cover the heights of the different plastic sleeves. In a clinical study of patients at standard follow-up, 21 knees were examined using standard radiographs. Radiographs using image intensification were then taken of the same knees to obtain radiographs with views parallel to the plane of the tibial tray. The results of the study on the phantom showed that a 1degrees deviation of the x-ray beam from the optimal position would obscure a 0.5-mm "radiolucency." This was true for radiolucencies of 2, 3, 4, and 5 mm. This was confirmed in the clinical study where < or = 4 mm of radiolucency was obscured on standard radiographs. Therefore, standard radiographs cannot be used to determine radiolucency. The 2-mm radiolucency normally associated with loosening is not clinically valid.


Asunto(s)
Prótesis de la Rodilla , Falla de Prótesis , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Radiografía , Tibia/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA