1.
Cardiol Young ; 33(10): 1840-1845, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36259096

RESUMEN

BACKGROUND: Right ventricular outflow tract intervention spans transcatheter, surgical, or hybrid pulmonary valve replacement methodologies. Standardised pre-procedure workup includes cardiac MRI to identify an intended valve site (landing zone). Our institutional practice includes measurement of the right ventricular outflow tract perimeter (circumference) of this site in end-systole. Our primary aim was to compare patients by their perimeter values to the palliative interventions performed (transcatheter versus surgical/hybrid methodologies). METHODS: Retrospective review of patients undergoing pulmonary valve replacement from January 2017 to 2021. We performed perimeter measurements at the intended valve site on advanced imaging; the outcomes of interventions were outlined via descriptive and statistical analyses. RESULTS: A total of 37 patients underwent pulmonary valve replacement that met study criteria - 21 transcatheter, 7 surgical, and 9 hybrid. Median age at intervention was 26 years (range 8-70). The mean end-systolic perimeter of the transcatheter cohort was 88.9 ± 8.7 mm and in the surgical/hybrid cohort measured 106.6 ± 7.5 mm. For the transcatheter cohort, the median "circularised" diameter derived from the perimeter measurement (divided by π) was 27.7 mm (range 24.3-32.4). Notably, this correlated (r = 0.93, p < 0.01) with the median diameter of the narrowest region during actual transcatheter right ventricular outflow tract balloon sizing (lateral imaging) of 27.1 mm (range 23.2-30.1). CONCLUSIONS: Right ventricular outflow tract perimeter measurement to determine circularised diameter is useful in planning pulmonary valve replacement in terms of candidacy of transcatheter versus the need for a surgical/hybrid approach. The circularised diameter correlates with transcatheter right ventricular outflow tract balloon sizing.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Humanos , Niño , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/cirugía , Estudios Retrospectivos , Cateterismo Cardíaco/métodos
2.
Echocardiography ; 39(1): 112-117, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34923683

RESUMEN

Infective endocarditis (IE) is a life-threatening disease associated with in-hospital mortality of nearly one in five cases. IE can destroy valvular tissue, which may rarely progress to aneurysm formation, most commonly at the anterior leaflet in instances of mitral valve involvement. We present a remarkable case of a patient with IE and a rare complication of a ruptured aneurysm of the posterior leaflet of the mitral valve. Two- and Three-dimensional transesophageal echocardiography, intra-operative videography, and histopathologic analysis revealed disruption at this unusual location-at the junction of the P2 and P3 scallops, surrounded by an annular abscess.


Asunto(s)
Aneurisma Roto , Endocarditis Bacteriana , Endocarditis , Aneurisma Cardíaco , Insuficiencia de la Válvula Mitral , Aneurisma Roto/complicaciones , Aneurisma Roto/diagnóstico por imagen , Ecocardiografía Transesofágica/métodos , Endocarditis/complicaciones , Endocarditis/diagnóstico por imagen , Endocarditis Bacteriana/complicaciones , Endocarditis Bacteriana/diagnóstico por imagen , Aneurisma Cardíaco/complicaciones , Aneurisma Cardíaco/diagnóstico por imagen , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Staphylococcus
3.
Radiographics ; 41(2): 399-424, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33646903

RESUMEN

Chest CT angiography (CTA) is essential in the diagnosis of acute aortic syndromes. Chest CTA quality can be optimized with attention to technical parameters pertaining to noncontrast imaging, timing of contrast-enhanced imaging, contrast material volume, kilovolt potential, tube-current modulation, and decisions regarding electrocardiographic-gating and ultra-fast imaging, which may affect the accurate diagnosis of acute aortic syndromes. An understanding of methods to apply to address suboptimal image quality is useful, as the accurate identification of acute aortic syndromes is essential for appropriate patient management. Acute aortic syndromes have high morbidity and mortality, particularly when involving the ascending aorta, and include classic aortic dissection, penetrating atherosclerotic ulcer, and acute intramural hematoma. An understanding of the pathogenesis and distinguishing imaging features of acute aortic syndromes and aortic rupture and some less common manifestations is helpful when interpreting imaging examinations. Related entities, such as ulcerated plaque, ulcerlike projections, and intramural blood pools, and mimics, such as vasculitis and aortic thrombus, are important to recognize; knowledge of these is important to avoid interpretive pitfalls. In addition, an awareness of postsurgical aortic changes can be useful when interpreting CTA examinations when patient history is incomplete. The authors review technical considerations when performing CTA, discuss acute aortic syndromes, and highlight diagnostic challenges encountered when interpreting aortic CTA examinations. ©RSNA, 2021.


Asunto(s)
Enfermedades de la Aorta , Disección Aórtica , Disección Aórtica/diagnóstico por imagen , Aorta , Enfermedades de la Aorta/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Hematoma , Humanos , Tomografía Computarizada por Rayos X
4.
J Comput Assist Tomogr ; 42(6): 840-849, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30371612

RESUMEN

Pulmonary embolism is the third most common acute cardiovascular disease. Dual-energy computed tomography perfusion imaging is a promising adjunct in the detection of acute PE providing simultaneous functional assessment of pulmonary perfusion alongside the high-resolution morphological information from computed tomography pulmonary angiography. We review the evidence to date and common causes of perfusion defects including artifacts, parenchymal, and vascular causes, and discuss its potential in furthering our understanding of physiology and pathophysiology in acute pulmonary embolism.


Asunto(s)
Embolia Pulmonar/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Artefactos , Angiografía por Tomografía Computarizada/métodos , Humanos
5.
MAGMA ; 31(1): 49-59, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29067539

RESUMEN

OBJECTIVES: Residual respiratory motion degrades image quality in conventional cardiac cine MRI (CCMRI). We evaluated whether a free-breathing (FB) radial imaging CCMRI sequence with compressed sensing reconstruction [extradimensional (e.g. cardiac and respiratory phases) golden-angle radial sparse parallel, or XD-GRASP] could provide better image quality than a conventional Cartesian breath-held (BH) sequence in an unselected population of patients undergoing clinical CCMRI. MATERIALS AND METHODS: One hundred one patients who underwent BH and FB imaging in a midventricular short-axis plane at a matching location were included. Visual and quantitative image analysis was performed by two blinded experienced readers, using a five-point qualitative scale to score overall image quality and visual signal-to-noise ratio (SNR) grade, with measures of noise and sharpness. End-diastolic and end-systolic left ventricular areas were also measured and compared for both BH and FB images. RESULTS: Image quality was generally better with the BH cines (overall quality grade for BH vs FB images 4 vs 2.9, p < 0.001; noise 0.06 vs 0.08 p < 0.001; SNR grade 4.1 vs 3, p < 0.001), except for sharpness (p = 0.48). There were no significant differences between BH and FB images regarding end-diastolic or end-systolic areas (p = 0.35 and p = 0.12). Eighteen of the 101 patients had poor BH image quality (grade 1 or 2). In this subgroup, the quality of the FB images was better (p = 0.0032), as was the SNR grade (p = 0.003), but there were no significant differences regarding noise and sharpness (p = 0.45 and p = 0.47). CONCLUSION: Although FB XD-GRASP CCMRI was visually inferior to conventional BH CCMRI in general, it provided improved image quality in the subgroup of patients with respiratory-motion-induced artifacts on BH images.


Asunto(s)
Técnicas de Imagen Cardíaca/métodos , Imagen por Resonancia Cinemagnética/métodos , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Contencion de la Respiración , Técnicas de Imagen Cardíaca/estadística & datos numéricos , Niño , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética/estadística & datos numéricos , Imagen por Resonancia Cinemagnética/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Mecánica Respiratoria , Estudios Retrospectivos , Relación Señal-Ruido , Adulto Joven
6.
Pediatr Cardiol ; 38(1): 103-114, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27837304

RESUMEN

Rapid prototyping facilitates comprehension of complex cardiac anatomy. However, determining when this additional information proves instrumental in patient management remains a challenge. We describe our experience with patient-specific anatomic models created using rapid prototyping from various imaging modalities, suggesting their utility in surgical and interventional planning in congenital heart disease (CHD). Virtual and physical 3-dimensional (3D) models were generated from CT or MRI data, using commercially available software for patients with complex muscular ventricular septal defects (CMVSD) and double-outlet right ventricle (DORV). Six patients with complex anatomy and uncertainty of the optimal management strategy were included in this study. The models were subsequently used to guide management decisions, and the outcomes reviewed. 3D models clearly demonstrated the complex intra-cardiac anatomy in all six patients and were utilized to guide management decisions. In the three patients with CMVSD, one underwent successful endovascular device closure following a prior failed attempt at transcatheter closure, and the other two underwent successful primary surgical closure with the aid of 3D models. In all three cases of DORV, the models provided better anatomic delineation and additional information that altered or confirmed the surgical plan. Patient-specific 3D heart models show promise in accurately defining intra-cardiac anatomy in CHD, specifically CMVSD and DORV. We believe these models improve understanding of the complex anatomical spatial relationships in these defects and provide additional insight for pre/intra-interventional management and surgical planning.


Asunto(s)
Ventrículo Derecho con Doble Salida/diagnóstico por imagen , Defectos del Tabique Interventricular/diagnóstico por imagen , Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Niño , Preescolar , Toma de Decisiones , Ventrículo Derecho con Doble Salida/cirugía , Femenino , Corazón/anatomía & histología , Defectos del Tabique Interventricular/cirugía , Humanos , Imagenología Tridimensional/métodos , Lactante , Masculino , Modelos Anatómicos , Impresión Tridimensional
7.
Catheter Cardiovasc Interv ; 87(5): 931-2, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27085031

RESUMEN

Delivery cable/attachment of the Amplatzer Septal Occluder holds the device at a suboptimal angle relative to the plane of the atrial septum prior to release A small gooseneck snare tightened on the hub can maintain flexible control of the device after release of the delivery cable This technique can improve safety of delivery in difficult cases if you think ahead.


Asunto(s)
Defectos del Tabique Interatrial , Dispositivo Oclusor Septal , Tabique Interatrial , Cateterismo Cardíaco/instrumentación , Humanos , Resultado del Tratamiento
8.
Catheter Cardiovasc Interv ; 88(1): 150-6, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25964108

RESUMEN

Ascending aortic and subvalvar left ventricular outflow tract (LVOT) pseudoaneurysms are rare complications following aortic valve or root replacement surgery. Clinically important paravalvular leaks are rare complications following any valve replacement surgery. We report an unusual case of sequential percutaneous closure of mitral prosthetic paravalvular leak and complex communicating ascending aortic and subvalvar LVOT pseudoaneurysms, which demonstrates the importance of multimodal imaging assessment surrounding percutaneous closure. © 2015 Wiley Periodicals, Inc.


Asunto(s)
Aneurisma Falso/terapia , Aneurisma de la Aorta/terapia , Cateterismo Cardíaco , Cateterismo Periférico , Aneurisma Cardíaco/terapia , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Mitral/cirugía , Aneurisma Falso/diagnóstico por imagen , Aneurisma de la Aorta/diagnóstico por imagen , Aortografía/métodos , Cateterismo Cardíaco/instrumentación , Cateterismo Periférico/instrumentación , Angiografía por Tomografía Computarizada , Ecocardiografía Transesofágica , Aneurisma Cardíaco/diagnóstico por imagen , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Falla de Prótesis , Recurrencia , Retratamiento , Dispositivo Oclusor Septal , Factores de Tiempo , Resultado del Tratamiento
9.
Pediatr Cardiol ; 37(8): 1436-1445, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27502109

RESUMEN

The Congenital Cardiac Catheterization Project on Outcomes (C3PO) launched in 2007 as a multi-center collaborative to establish standardized and comparable metrics for pediatric cardiac catheterization procedures. The limitations of larger registries at the time led to the development of the next phase in 2013, C3PO-Quality Improvement (C3PO-QI), focusing on instituting QI initiatives within the field. The objective of this manuscript is to provide a detailed overview of C3PO-QI and report data on case characteristics and outcome metrics being explored. C3PO-QI was designed to cultivate institutional collaboration during implementation of its initiatives. A database and website were developed to support data entry and on-demand reporting. The registry prospectively captures pediatric cardiac catheterization data among 15 hospitals. The present study includes case demographic data (n) and quality metric reporting by case type, age, and radiation dose variables. This dataset includes 13,135 cases entered into the database between 1/1/2014 and 12/31/2015. Interventional cases make up the highest percentage by case mix distribution (48 %), and patients <1 years make up the highest percentage by age distribution (26 %). The ratio of diagnostic and interventional procedures performed changes by age group. Application of QI metric shows all procedure types surpassing metric goals. Large volume data collection, such as in C3PO-QI, allows for meaningful interpretation of data. C3PO-QI is uniquely poised to deliver fast-paced changes in the field. Although the project initiatives are specific to pediatric cardiac catheterization, the implementation of the project and utilization of real-time reporting is generalizable to other specialties and multi-center collaboratives.


Asunto(s)
Cateterismo Cardíaco , Niño , Bases de Datos Factuales , Cardiopatías Congénitas , Humanos , Mejoramiento de la Calidad , Sistema de Registros
10.
J Interv Cardiol ; 28(4): 380-9, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26086715

RESUMEN

OBJECTIVES: To investigate technical approaches for transcatheter closure of coronary artery fistula based on anatomic type of the fistula. BACKGROUND: The variability in coronary artery fistulae (CAF) anatomy that necessitates different transcatheter closure (TCC) approaches has not been well documented. METHODS: Records of patients with CAF who underwent TCC at 2 centers were reviewed for technical details and procedural outcome. CAF were classified as proximal and distal. TCC approaches employed were arterio-venous or arterio-arterial loop, retrograde arterial, and antegrade venous. RESULTS: Eighteen patients with CAF, mean age 12.6 years (0.07-60), 11 male (61%), underwent TCC. All CAF drained predominantly into the right side of the heart. Types of CAF were proximal in 15 and distal in 3 patients. CAF calibers were large in 7, medium in 9, and small in 2 patients. The arterio-venous loop approach was used in the majority of the cases (11 patients) and the CAF size were medium to large. The retrograde arterial approach was used in 4; of these, 3 patients had small to medium sized CAF. In 2 patients with long tortuous CAF an antegrade venous approach was employed. TCC was successful in 17 of the 18 patients (94.4%). There were no peri-procedural deaths or vascular complications. CONCLUSIONS: This study documents transcatheter closure approaches for CAF and device selection based on fistula origin. The choices of TCC technique and device selection vary, and are primarily determined by the heterogeneous anatomic characteristics of the fistulae.


Asunto(s)
Cateterismo Cardíaco/métodos , Enfermedad de la Arteria Coronaria/terapia , Fístula Vascular/terapia , Adolescente , Adulto , Niño , Vasos Coronarios , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
11.
Catheter Cardiovasc Interv ; 84(1): 94-100, 2014 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-24989344

RESUMEN

OBJECTIVES: To identify complications and measures that can be undertaken to prevent complications from transhepatic central venous access. BACKGROUND: Utility and safety data from a large experience of patients undergoing transhepatic venous access are lacking. METHODS: The records of patients who underwent transhepatic venous access between June 2000 and October 2012 at The Center for Pediatric and Congenital Heart Disease at The Cleveland Clinic were reviewed. RESULTS: One hundred twenty-four transhepatic procedures were performed in 81 patients. The median weight of the patients was 6.3 (2.2-94) kg at a median age of 7 months (2 weeks to 35 years). Diagnostic catheterizations were performed in 75, interventions in 39, and central venous line placement in 91 procedures. The median maximum sheath size inserted was 8 (4-14) French. There were 10 (8%) major adverse events in 8 procedures-bleeding related (n = 6 with 1 death as a result) or complete heart block with instability or requiring intervention (n = 4). Heart block persisted after the catheterization in three patients (2 days, 2 weeks, 1 month). Minor adverse events (transient heart block) occurred in 5 (4 %) procedures. Weight, age, and French size of sheath (P = 0.46, 0.84, and 0.18) were not associated with complications. In addition, time to gain access was not different between non-complicated and complicated cases (median 19.5 versus 15.1 min, P = 0.72). Diagnostic and interventional procedures were not associated with more complications compared with procedures involving central venous line placement alone (P = 0.5). CONCLUSIONS: Transhepatic access is an extremely useful modality of access to the heart and vascular structures in some patients with complex heart disease. Prevention of complications should focus on minimizing bleeding risks and heart block.


Asunto(s)
Cateterismo Cardíaco/métodos , Cateterismo Venoso Central/efectos adversos , Predicción , Cardiopatías Congénitas/diagnóstico , Adolescente , Adulto , Cateterismo Cardíaco/efectos adversos , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Estudios Retrospectivos , Adulto Joven
12.
Catheter Cardiovasc Interv ; 84(2): 204-10, 2014 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-24039138

RESUMEN

OBJECTIVES: To describe the effectiveness of the Helex Septal Occluder (HSO) to close multiple atrial septal defects (mASDs). Background : Limited information is available describing closure of mASDs with the HSO. METHODS: A total of 28 patients who underwent closure of mASDs with the HSO were identified by retrospective review of our catheterization database between 2001 and 2012. Procedural details and follow up information were collected. RESULTS: Median age was 19.2 years, median weight 48 kg, with 10 (36%) patients weighing <25 kg. Indication for closure was RV enlargement (RVE) in all patients and additionally neurologic events occurred in 3/28 (11%). Median stop-flow diameter for the largest ASD was 14 (4-23) mm. One HSO was implanted in 21/28 (75%), 2 in 6/28 (21%), and 3 in 1/28 (4%). One embolization and one transient arrhythmia occurred with no sequelae. Immediate residual shunt was absent in 5/28 (18%), trivial in 15/28 (54%), small in 6/28 (21%), and moderate in 2/28 (7%). Of the 25 patients with ≥6 months follow-up (median 53 months), residual shunt was absent in 13/25 (52%), trivial in 5/25 (20%), and small in 7/25 (28%). RVE resolved in all but one patient with no other associated lesions and ≥6 months of follow-up. No patient with prior neurological event had recurrence at last follow-up. CONCLUSIONS: We conclude that closure of mASDs with ≥1 HSO is effective with a low complication rate. The ability of HSO devices to overlap or sandwich each other may facilitate safe implantation of multiple devices in smaller patients.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Defectos del Tabique Interatrial/terapia , Dispositivo Oclusor Septal , Peso Corporal , Cateterismo Cardíaco/efectos adversos , Ecocardiografía Doppler en Color , Ecocardiografía Transesofágica , Femenino , Defectos del Tabique Interatrial/diagnóstico , Defectos del Tabique Interatrial/fisiopatología , Hemodinámica , Humanos , Masculino , Diseño de Prótesis , Radiografía Intervencional , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
13.
Catheter Cardiovasc Interv ; 82(1): 132-42, 2013 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-23408662

RESUMEN

BACKGROUND: To evaluate postdiscovery outcome of coronary artery fistulae (CAF). CAF treatment sequelae and risk factors for coronary thrombosis have not been adequately evaluated. METHODS: Outcome on follow-up of 16 patients with CAF was reviewed. Risk factors for adverse coronary events were assessed based on type, size, and treatment of CAF. RESULTS: Median age was 10 years (0.01-56). Seven patients had large, four medium, and five small sizes CAF. Eight had proximal and 8 distal type CAF. There were 7 in the intervention group (IG) and 9 in nonintervention (NIG). In the IG, 1 had myocardial infarction (MI) <24 hr with distal thrombosis following large distal type CAF closure. Follow-up angiograms in 6 pts showed; decrease in conduit coronary artery size towards normal in 4, 1 had discrete intimal stenosis, persistent coronary dilatation in 1, thrombosis of residual proximal fistula segment without MI in 2, evidence of revascularization in 2 and neovascularization in 1 patient. In the NIG, 6 of the 9 pts available for follow-up were asymptomatic. Angiogram available in 1 patient showed persistent coronary dilatation with partial closure. CONCLUSION: Post-CAF treatment sequelae include thrombosis and MI, revascularization, persistent coronary dilatation, remodeling, and decrease in conduit coronary artery size towards normal. The large size distal type of CAF may be at highest risk for coronary thrombosis post closure. The optimal treatment approach to various morphologies of CAF at various ages remains to be determined.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Enfermedad de la Arteria Coronaria/cirugía , Trombosis Coronaria/etiología , Vasos Coronarios/patología , Fístula/cirugía , Adolescente , Adulto , Niño , Preescolar , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Trombosis Coronaria/diagnóstico , Trombosis Coronaria/patología , Vasos Coronarios/diagnóstico por imagen , Femenino , Fístula/diagnóstico , Humanos , Lactante , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Selección de Paciente , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Intervencional , Adulto Joven
14.
Int J Cardiol Cardiovasc Risk Prev ; 17: 200179, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36923366

RESUMEN

Background: Obesity is prevalent among patients with hypertrophic cardiomyopathy (HCM). Obese HCM patients have greater wall thickness, LV mass, worse hemodynamic function and NYHA class. Weight loss may favorably influence the HCM phenotype. Case summary: We describe six patients with hypertrophic cardiomyopathy who lost weight through diet and lifestyle changes (n = 4) or bariatric surgery (n = 2). Radiographic imaging, with cardiac MRI or CT scan, was performed before and after their weight loss. There was a mean decrease in LV mass and indexed LV mass, and a mean numerical decrease in mean wall thickness in up to 14 out of 18 LV segments. There was also NYHA class reduction in symptoms. Discussion: In this case series, we have shown that substantial weight loss in HCM patients can be associated with a decrease in LV mass, wall thickness and improvement in symptoms. These observations indicate the potential for positive remodeling of the heart by weight loss. Prospective studies of the benefits of weight loss in HCM are needed.

15.
Catheter Cardiovasc Interv ; 79(3): 422-6, 2012 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-22162341

RESUMEN

After the Norwood procedure for palliation of hypoplastic left heart syndrome, there is still significant interstage and late mortality with often unclear etiology. An important, but possibly under-recognized complication of the Norwood operation is the potential for coronary insufficiency from pre-coronary stenosis due to kinking or scarring at the anastomosis between the native and neo-aorta. We report a case of a clinically thriving 10-month old infant status post bidirectional Glenn who had acute ischemic changes on electrocardiogram (ECG) during induction of anesthesia for elective bilateral herniorrhaphy. A discrete narrowing in the native aorta to neo-aorta anastomosis was identified. A stent was placed emergently to restore adequate coronary blood flow after failure of simple angioplasty to adequately improve the stenosis.


Asunto(s)
Anestesia General/efectos adversos , Enfermedades de la Aorta/etiología , Arteriopatías Oclusivas/etiología , Síndrome del Corazón Izquierdo Hipoplásico/cirugía , Isquemia Miocárdica/etiología , Procedimientos de Norwood/efectos adversos , Angioplastia de Balón/instrumentación , Enfermedades de la Aorta/diagnóstico , Enfermedades de la Aorta/fisiopatología , Enfermedades de la Aorta/terapia , Arteriopatías Oclusivas/diagnóstico , Arteriopatías Oclusivas/terapia , Constricción Patológica , Circulación Coronaria , Ecocardiografía Doppler en Color , Electrocardiografía , Herniorrafia , Humanos , Lactante , Masculino , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatología , Isquemia Miocárdica/terapia , Cuidados Paliativos , Stents , Factores de Tiempo , Resultado del Tratamiento
16.
Aorta (Stamford) ; 10(3): 104-113, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36318931

RESUMEN

BACKGROUND: Coronavirus disease-19 (COVID-19) remains a public health crisis. The epidemiology of COVID-19-associated large- and medium-sized-vessel pathology is not well characterized. The aim of this study is to identify patients with possible COVID-19-associated large- and medium-sized-vessel pathology based on computed tomography (CT) imaging to provide insight into this rare, but potentially devastating, cardiovascular manifestation. METHODS: This is a single-center retrospective review of patients with CT chest, abdomen, and/or pelvis concerning for large- and medium-vessel pathology and confirmed COVID-19 infection from March 1, 2020 to October 31, 2020. RESULTS: During the study period, 6,553 CT reports were reviewed and pertinent imaging was identified in 139 patients. Of these, 8 patients (median age: 59 years, range 51-82) were COVID-19 positive. All patients had preexisting cardiovascular risk factors and three (37.5%) had an autoimmune disease. Four patients were never hospitalized for COVID-19. Among these, two presented to the hospital at a median of 39 days (range: 27-50) after their initial COVID-19 test with chest and back pain where imaging revealed extensive aortic pathology. One patient required surgical management for aortic pathology. All other patients were treated with expectant management and outpatient follow-up. CONCLUSION: The clinical and radiological presentations of COVID-19-associated large- and medium-vessel pathology are heterogeneous and can be a late finding after COVID-19 recovery. Close clinical follow-up and surveillance imaging for large- and medium-sized-vessel pathology may be warranted in COVID-19 patients.

17.
Acad Radiol ; 28(12): 1645-1653, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34740527

RESUMEN

RATIONALE AND OBJECTIVES: Asymptomatic COVID-19 carriers and insufficient testing make containment of the virus difficult. The purpose of this study was to determine if unexpected lung base findings on abdominopelvic CTs concerning for COVID-19 infection could serve as a surrogate for the diagnosis of COVID-19 in the community. MATERIALS AND METHODS: A database search of abdominopelvic CT reports from March 1,2020 to May 2,2020 was performed for keywords suggesting COVID-19 infection by lung base findings. COVID-19 status, respiratory symptoms, laboratory parameters and patient outcomes (hospitalization, ICU admission and/or intubation, and death) were recorded. The trend in cases of unexpected concerning lung base findings on abdominopelvic CT at our institution was compared to the total number of confirmed new cases in NYC over the same time period. RESULTS: The trend in abnormal lung base findings on abdominopelvic CT at our institution correlated with the citywide number of confirmed new cases, including rise and subsequent fall in total cases. The trend was not mediated by COVID-19 testing status or number of tests performed. Patients with respiratory symptoms had significantly higher ferritin (median = 995ng/ml vs 500ng/ml, p = 0.027) and death rate (8/24, 33% vs 4/54, 9%, p = 0.018) compared to those without. CONCLUSION: The rise and fall of unexpected lung base findings suggestive of COVID-19 infection on abdominopelvic CT in patients without COVID-19 symptoms correlated with the number of confirmed new cases throughout NYC from the same time period. A model using abdominopelvic CT lung base findings can serve as a surrogate for future COVID-19 outbreaks.


Asunto(s)
COVID-19 , Prueba de COVID-19 , Brotes de Enfermedades , Humanos , Pulmón , Ciudad de Nueva York/epidemiología , SARS-CoV-2
18.
Eur Heart J Case Rep ; 5(6): ytab235, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34222784

RESUMEN

BACKGROUND: Acquired pulmonary vein stenosis (PVS) is an infrequent complication of atrial fibrillation ablation that is often misdiagnosed due to predominant respiratory symptoms. It can result in pulmonary venous hypertension, with varying presentations, ranging from shortness of breath to haemoptysis. CASE SUMMARY: We report two patients with a history of paroxysmal atrial fibrillation treated with radiofrequency ablation and pulmonary vein (PV) isolation, who subsequently developed PVS. Case 1 initially presented with indolent symptoms of shortness of breath and cough. He was initially diagnosed with and treated for pneumonia. In contrast, Case 2 presented with massive haemoptysis, requiring intubation and intensive care unit admission. Both patients were eventually diagnosed with PVS by computed tomography. They were treated with PV angioplasty and stenting. DISCUSSION: While previously limited to the congenital heart disease population, PVS is occurring more frequently now in adult patients as a complication of ablation procedures. It is most effectively treated with angioplasty and stent implantation but has a high rate of recurrence.

19.
World J Pediatr Congenit Heart Surg ; 12(2): 213-219, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33684011

RESUMEN

BACKGROUND: Surgical pulmonary artery banding (PAB) has been limited in practice because of later requirement for surgical removal or adjustment. The aim of this study is to describe our experience creating a dilatable PAB via transcatheter balloon dilation (TCBD) in congenital heart disease (CHD) patients. METHODS: Retrospective chart review of adjustable PAB-outline anatomical variants palliated and patient outcomes. RESULTS: Sixteen patients underwent dilatable PAB-median age 52 days (range 4-215) and weight 3.12 kg (1.65-5.8). Seven (44%) of the patients were premature, 11 (69%) had ventricular septal defect(s) with pulmonary over-circulation, four (25%) atrioventricular septal defects, and four (25%) single ventricle physiology. Subsequent to the index procedure: five patients have undergone intracardiac complete repair, six patients remain well palliated with no additional intervention, and four single ventricles await their next palliation. One patient died from necrotizing enterocolitis (unrelated to PAB) and one patient required a pericardiocentesis postoperatively. Five patients underwent TCBD of the PAB without complication-Two had one TCBD, two had two TCBD, and another had three TCBD. The median change in saturation was 14% (complete range 6-22) and PAB diameter 1.7 mm (complete range 1.1-5.2). Median time from PAB to most recent outpatient follow-up was 868 days (interquartile range 190-1,079). CONCLUSIONS: Our institution has standardized a PAB technique that allows for transcatheter incremental increases in pulmonary blood flow over time. This methodology has proven safe and effective enough to supplant other institutional techniques of limiting pulmonary blood flow in most patients-allowing for interval growth or even serving as the definitive palliation.


Asunto(s)
Cardiopatías Congénitas/cirugía , Cuidados Paliativos/métodos , Arteria Pulmonar/cirugía , Circulación Pulmonar/fisiología , Procedimientos Quirúrgicos Vasculares/métodos , Femenino , Cardiopatías Congénitas/fisiopatología , Humanos , Lactante , Recién Nacido , Masculino , Arteria Pulmonar/fisiopatología , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS