Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Arch Orthop Trauma Surg ; 136(5): 693-700, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26971267

RESUMEN

INTRODUCTION: The aim of this study was to investigate if preoperative measurements of the femoral valgus angle (FVA) affected the mechanical alignment, individual component positions and clinical outcome in total knee arthroplasty (TKA). METHODS: 120 patients were randomized into two groups. In one group (control), a fixed FVA for the intramedullary femoral guide was set at 7°, whereas in the other group (measured) FVA was measured preoperatively on long hip-knee-ankle radiographs, and the angle for the distal femoral cut was set accordingly. Preoperatively and 1 year after TKA, range of motion (ROM) and Knee Society Score (KSS) were assessed. Postoperatively, the coronal alignments of the components and the mechanical alignment were measured comparing the rate of outliers which deviated more than 3° from the neutral mechanical axis. RESULTS: 104 patients remained for the radiological analysis (52 in each group). There were no significant differences either in the mean preoperative or postoperative mechanical alignment, or femoral or tibial component alignment; also, there were no differences in the number of postoperative mechanical axis or tibial component alignment outliers. However, the number of femoral component alignment outliers was significantly higher in the control group. 97 patients were available for clinical outcome analysis. Preoperatively, the groups did not differ significantly with respect to KSS or ROM. The postoperative ROM and KSS functional subscale scores were similar between the groups. However, there was slightly but significantly better postoperative KSS objective subscale score in the measured group. CONCLUSIONS: Preoperative FVA measurement and following femoral distal cut adjustments did not affect overall leg alignment postoperatively, while positioning of femoral component was improved together with minor improvements in objective KSS subscale scores.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Anciano , Anciano de 80 o más Años , Tobillo/diagnóstico por imagen , Femenino , Fémur/diagnóstico por imagen , Fémur/cirugía , Humanos , Rodilla/diagnóstico por imagen , Rodilla/fisiopatología , Rodilla/cirugía , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/fisiopatología , Estudios Prospectivos , Radiografía , Rango del Movimiento Articular , Tibia/diagnóstico por imagen , Tibia/cirugía , Resultado del Tratamiento
2.
Acta Orthop ; 86(6): 728-33, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26058850

RESUMEN

BACKGROUND AND PURPOSE: Postoperative muscle strength and component alignment are important factors affecting functional results after total knee arthroplasty (TKA). We are not aware of any studies that have investigated the relationship between them. We therefore investigated whether coronal malalignment of the mechanical axis and/or of individual implant components would affect knee muscle strength and function 1 year after TKA surgery. PATIENTS AND METHODS: We included 120 consecutive osteoarthritis (OA) patients admitted for TKA. Preoperative active range of motion (ROM) of the knee, patient age, sex, and BMI were recorded and the Knee Society score (KSS) and knee joint extensor/flexor muscle strength were assessed. At 1-year follow-up, the mechanical and coronal component alignment was measured from a postoperative long standing radiograph, and ROM, KSS, and muscle strength measurements were taken in 91 patients. Functional outcome and muscle strength measurements were compared between normally aligned and malaligned TKA groups. RESULTS: 29 of 91 TKAs were malaligned, i.e. they deviated more than 3° from the neutral mechanical axis. 18 femoral components and 15 tibial components were malaligned. Before surgery, the malaligned and normally aligned groups were similar regarding sex distribution, BMI, ROM, KSS, and muscle strength. At the 1-year follow-up, the differences between the groups regarding knee joint function and muscle strength were small, not statistically significant, and barely clinically relevant. INTERPRETATION: Moderate varus/valgus malalignment of the mechanical axis or of individual components has no relevant clinical effect on function or muscle strength 1 year after TKA surgery.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Desviación Ósea/complicaciones , Rodilla/fisiología , Fuerza Muscular , Anciano , Desviación Ósea/etiología , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Osteoartritis de la Rodilla/cirugía , Rango del Movimiento Articular/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA