Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Revista
País de afiliación
Intervalo de año de publicación
1.
Vasa ; 47(5): 393-401, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29952252

RESUMEN

BACKGROUND: Vascular access site-related complications are frequent in the context of transfemoral transcatheter aortic valve replacement (TAVR). The implantation of a covered stent graft is an effective treatment option for bleeding control. However, the external iliac and common femoral arteries are exposed to flexion of the hip joint. Therefore, stent compression and stent/strut fractures may occur, facilitating stent occlusion. PATIENTS AND METHODS: In all 389 patients who received transfemoral TAVR from 2013-2015 at the Düsseldorf Heart Centre, we monitored the management of vascular access site-related complications. Our analyses focused on immediate technical success and bleeding control, primary patency, and the occurrence of stent/strut fractures after six to 12 months of follow-up. RESULTS: Vascular access site-related complications occurred in 13 % (n = 51), whereof in 10 patients, the bleeding was successfully managed by prolonged compression. In 40 out of 51 patients, a covered stent graft was implanted in the common femoral artery, leading to 100 % immediate bleeding control. After a mean follow-up of 334 ± 188 days, 28 stents out of 29 patients with completed follow-up (excluding e. g. death) were without flow-limiting stenosis (primary patency 97 %) or relevant stent compression (diameter pre/post 8.6/8.1 mm, p = 0.048, late lumen loss 1.1 ± 0.2 mm, mean flow velocity 92 ± 34 cm/s). In four asymptomatic patients, stent/strut fractures were detected (14 %) without flow-limiting stenosis. CONCLUSIONS: The implantation of a covered stent graft is highly effective and safe to control vascular access site-related complications after TAVR. Stent/strut fractures in the flexible segment of the common femoral artery may occur, as consequently verified by X-ray visualization, but show no impairment on flow or clinical parameters after six to 12 months.


Asunto(s)
Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Cateterismo Periférico/métodos , Procedimientos Endovasculares/instrumentación , Arteria Femoral/cirugía , Hemorragia/cirugía , Falla de Prótesis , Stents , Técnicas de Sutura/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Implantación de Prótesis Vascular/efectos adversos , Cateterismo Periférico/efectos adversos , Procedimientos Endovasculares/efectos adversos , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Alemania , Hemorragia/diagnóstico por imagen , Hemorragia/etiología , Humanos , Masculino , Diseño de Prótesis , Punciones , Flujo Sanguíneo Regional , Técnicas de Sutura/efectos adversos , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA