RESUMEN
Background The level of background parenchymal enhancement (BPE) at breast MRI provides predictive and prognostic information and can have diagnostic implications. However, there is a lack of standardization regarding BPE assessment. Purpose To investigate how well results of quantitative BPE assessment methods correlate among themselves and with assessments made by radiologists experienced in breast MRI. Materials and Methods In this pseudoprospective analysis of 5773 breast MRI examinations from 3207 patients (mean age, 60 years ± 10 [SD]), the level of BPE was prospectively categorized according to the Breast Imaging Reporting and Data System by radiologists experienced in breast MRI. For automated extraction of BPE, fibroglandular tissue (FGT) was segmented in an automated pipeline. Four different published methods for automated quantitative BPE extractions were used: two methods (A and B) based on enhancement intensity and two methods (C and D) based on the volume of enhanced FGT. The results from all methods were correlated, and agreement was investigated in comparison with the respective radiologist-based categorization. For surrogate validation of BPE assessment, how accurately the methods distinguished premenopausal women with (n = 50) versus without (n = 896) antihormonal treatment was determined. Results Intensity-based methods (A and B) exhibited a correlation with radiologist-based categorization of 0.56 ± 0.01 and 0.55 ± 0.01, respectively, and volume-based methods (C and D) had a correlation of 0.52 ± 0.01 and 0.50 ± 0.01 (P < .001). There were notable correlation differences (P < .001) between the BPE determined with the four methods. Among the four quantitation methods, method D offered the highest accuracy for distinguishing women with versus without antihormonal therapy (P = .01). Conclusion Results of different methods for quantitative BPE assessment agree only moderately among themselves or with visual categories reported by experienced radiologists; intensity-based methods correlate more closely with radiologists' ratings than volume-based methods. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Mann in this issue.
Asunto(s)
Neoplasias de la Mama , Mama , Imagen por Resonancia Magnética , Humanos , Femenino , Persona de Mediana Edad , Imagen por Resonancia Magnética/métodos , Neoplasias de la Mama/diagnóstico por imagen , Mama/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Adulto , Estudios Prospectivos , Aumento de la Imagen/métodos , Anciano , Reproducibilidad de los Resultados , Estudios RetrospectivosRESUMEN
BACKGROUND: To compare denoising diffusion probabilistic models (DDPM) and generative adversarial networks (GAN) for recovering contrast-enhanced breast magnetic resonance imaging (MRI) subtraction images from virtual low-dose subtraction images. METHODS: Retrospective, ethically approved study. DDPM- and GAN-reconstructed single-slice subtraction images of 50 breasts with enhancing lesions were compared to original ones at three dose levels (25%, 10%, 5%) using quantitative measures and radiologic evaluations. Two radiologists stated their preference based on the reconstruction quality and scored the lesion conspicuity as compared to the original, blinded to the model. Fifty lesion-free maximum intensity projections were evaluated for the presence of false-positives. Results were compared between models and dose levels, using generalized linear mixed models. RESULTS: At 5% dose, both radiologists preferred the GAN-generated images, whereas at 25% dose, both radiologists preferred the DDPM-generated images. Median lesion conspicuity scores did not differ between GAN and DDPM at 25% dose (5 versus 5, p = 1.000) and 10% dose (4 versus 4, p = 1.000). At 5% dose, both readers assigned higher conspicuity to the GAN than to the DDPM (3 versus 2, p = 0.007). In the lesion-free examinations, DDPM and GAN showed no differences in the false-positive rate at 5% (15% versus 22%), 10% (10% versus 6%), and 25% (6% versus 4%) (p = 1.000). CONCLUSIONS: Both GAN and DDPM yielded promising results in low-dose image reconstruction. However, neither of them showed superior results over the other model for all dose levels and evaluation metrics. Further development is needed to counteract false-positives. RELEVANCE STATEMENT: For MRI-based breast cancer screening, reducing the contrast agent dose is desirable. Diffusion probabilistic models and generative adversarial networks were capable of retrospectively enhancing the signal of low-dose images. Hence, they may supplement imaging with reduced doses in the future. KEY POINTS: ⢠Deep learning may help recover signal in low-dose contrast-enhanced breast MRI. ⢠Two models (DDPM and GAN) were trained at different dose levels. ⢠Radiologists preferred DDPM at 25%, and GAN images at 5% dose. ⢠Lesion conspicuity between DDPM and GAN was similar, except at 5% dose. ⢠GAN and DDPM yield promising results in low-dose image reconstruction.
Asunto(s)
Neoplasias de la Mama , Medios de Contraste , Imagen por Resonancia Magnética , Humanos , Femenino , Estudios Retrospectivos , Medios de Contraste/administración & dosificación , Neoplasias de la Mama/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Modelos Estadísticos , Adulto , AncianoRESUMEN
Magnetic resonance imaging (MRI) is the clinical method of choice for cartilage imaging in the context of degenerative and nondegenerative joint diseases. The MRI-based definitions of osteoarthritis rely on the detection of osteophytes, cartilage pathologies, bone marrow edema and meniscal lesions but currently a scientific consensus is lacking. In the clinical routine proton density-weighted, fat-suppressed 2D turbo spin echo sequences with echo times of 30-40â¯ms are predominantly used, which are sufficiently sensitive and specific for the assessment of cartilage. The additionally acquired T1-weighted sequences are primarily used for evaluating other intra-articular and periarticular structures. Diagnostically relevant artifacts include magic angle and chemical shift artifacts, which can lead to artificial signal enhancement in cartilage or incorrect representations of the subchondral lamina and its thickness. Although scientifically validated, high-resolution 3D gradient echo sequences (for cartilage segmentation) and compositional MR sequences (for quantification of physical tissue parameters) are currently reserved for scientific research questions. The future integration of artificial intelligence techniques in areas such as image reconstruction (to reduce scan times while maintaining image quality), image analysis (for automated identification of cartilage defects), and image postprocessing (for automated segmentation of cartilage in terms of volume and thickness) will significantly improve the diagnostic workflow and advance the field further.
Asunto(s)
Enfermedades de los Cartílagos , Cartílago Articular , Osteoartritis de la Rodilla , Humanos , Osteoartritis de la Rodilla/patología , Cartílago Articular/patología , Inteligencia Artificial , Enfermedades de los Cartílagos/patología , Imagen por Resonancia Magnética/métodosRESUMEN
High-quality magnetic resonance (MR) imaging is essential for the precise assessment of the knee joint and plays a key role in the diagnostics, treatment and prognosis. Intact cartilage tissue is characterized by a smooth surface, uniform tissue thickness and an organized zonal structure, which are manifested as depth-dependent signal intensity variations. Cartilage pathologies are identifiable through alterations in signal intensity and morphology and should be communicated based on a precise terminology. Cartilage pathologies can show hyperintense and hypointense signal alterations. Cartilage defects are assessed based on their depth and should be described in terms of their location and extent. The following symptom constellations are of overarching clinical relevance in image reading and interpretation: symptom constellations associated with rapidly progressive forms of joint degeneration and unfavorable prognosis, accompanying symptom constellations mostly in connection with destabilizing meniscal lesions and subchondral insufficiency fractures (accelerated osteoarthritis) as well as symptoms beyond the "typical" degeneration, especially when a discrepancy is observed between (minor) structural changes and (major) synovitis and effusion (inflammatory arthropathy).
Asunto(s)
Cartílago Articular , Osteoartritis de la Rodilla , Humanos , Osteoartritis de la Rodilla/complicaciones , Osteoartritis de la Rodilla/patología , Cartílago Articular/patología , Progresión de la Enfermedad , Articulación de la Rodilla/patología , Imagen por Resonancia Magnética/métodosRESUMEN
OBJECTIVES: Chronic liver diseases (CLDs) have diverse etiologies. To better classify CLDs, we explored the ability of longitudinal multiparametric MRI (magnetic resonance imaging) in depicting alterations in liver morphology, inflammation, and hepatocyte and macrophage activity in murine high-fat diet (HFD)- and carbon tetrachloride (CCl 4 )-induced CLD models. MATERIALS AND METHODS: Mice were either untreated, fed an HFD for 24 weeks, or injected with CCl 4 for 8 weeks. Longitudinal multiparametric MRI was performed every 4 weeks using a 7 T MRI scanner, including T1/T2 relaxometry, morphological T1/T2-weighted imaging, and fat-selective imaging. Diffusion-weighted imaging was applied to assess fibrotic remodeling and T1-weighted and T2*-weighted dynamic contrast-enhanced MRI and dynamic susceptibility contrast MRI using gadoxetic acid and ferucarbotran to target hepatocytes and the mononuclear phagocyte system, respectively. Imaging data were associated with histopathological and serological analyses. Principal component analysis and clustering were used to reveal underlying disease patterns. RESULTS: The MRI parameters significantly correlated with histologically confirmed steatosis, fibrosis, and liver damage, with varying importance. No single MRI parameter exclusively correlated with 1 pathophysiological feature, underscoring the necessity for using parameter patterns. Clustering revealed early-stage, model-specific patterns. Although the HFD model exhibited pronounced liver fat content and fibrosis, the CCl 4 model indicated reduced liver fat content and impaired hepatocyte and macrophage function. In both models, MRI biomarkers of inflammation were elevated. CONCLUSIONS: Multiparametric MRI patterns can be assigned to pathophysiological processes and used for murine CLD classification and progression tracking. These MRI biomarker patterns can directly be explored clinically to improve early CLD detection and differentiation and to refine treatments.
Asunto(s)
Modelos Animales de Enfermedad , Hepatopatías , Imágenes de Resonancia Magnética Multiparamétrica , Animales , Ratones , Imágenes de Resonancia Magnética Multiparamétrica/métodos , Hepatopatías/diagnóstico por imagen , Hepatopatías/patología , Masculino , Ratones Endogámicos C57BL , Enfermedad Crónica , Tetracloruro de Carbono/toxicidad , Dieta Alta en Grasa , Hígado/diagnóstico por imagen , Hígado/patologíaRESUMEN
BACKGROUND: Quantitative techniques such as T2 and T1ρ mapping allow evaluating the cartilage and meniscus. We evaluated multi-interleaved X-prepared turbo-spin echo with intuitive relaxometry (MIXTURE) sequences with turbo spin-echo (TSE) contrast and additional parameter maps versus reference TSE sequences in an in situ model of human cartilage defects. METHODS: Standardized cartilage defects of 8, 5, and 3 mm in diameter were created in the lateral femora of ten human cadaveric knee specimens (81 ± 10 years old; nine males, one female). MIXTURE sequences providing proton density-weighted fat-saturated images and T2 maps or T1-weighted images and T1ρ maps as well as the corresponding two- and three-dimensional TSE reference sequences were acquired before and after defect creation (3-T scanner; knee coil). Defect delineability, bone texture, and cartilage relaxation times were quantified. Appropriate parametric or non-parametric tests were used. RESULTS: Overall, defect delineability and texture features were not significantly different between the MIXTURE and reference sequences (p ≤ 0.47). After defect creation, relaxation times significantly increased in the central femur (T2pre = 51 ± 4 ms [mean ± standard deviation] versus T2post = 56 ± 4 ms; p = 0.002) and all regions combined (T1ρpre = 40 ± 4 ms versus T1ρpost = 43 ± 4 ms; p = 0.004). CONCLUSIONS: MIXTURE permitted time-efficient simultaneous morphologic and quantitative joint assessment based on clinical image contrasts. While providing T2 or T1ρ maps in clinically feasible scan time, morphologic image features, i.e., cartilage defects and bone texture, were comparable between MIXTURE and reference sequences. RELEVANCE STATEMENT: Equally time-efficient and versatile, the MIXTURE sequence platform combines morphologic imaging using familiar contrasts, excellent image correspondence versus corresponding reference sequences and quantitative mapping information, thereby increasing the diagnostic value beyond mere morphology. KEY POINTS: ⢠Combined morphologic and quantitative MIXTURE sequences are based on three-dimensional TSE contrasts. ⢠MIXTURE sequences were studied in an in situ human cartilage defect model. ⢠Morphologic image features, i.e., defect delineabilty and bone texture, were investigated. ⢠Morphologic image features were similar between MIXTURE and reference sequences. ⢠MIXTURE allowed time-efficient simultaneous morphologic and quantitative knee joint assessment.
Asunto(s)
Cadáver , Cartílago Articular , Articulación de la Rodilla , Imagen por Resonancia Magnética , Humanos , Masculino , Imagen por Resonancia Magnética/métodos , Femenino , Cartílago Articular/diagnóstico por imagen , Articulación de la Rodilla/diagnóstico por imagen , Anciano de 80 o más Años , AncianoRESUMEN
PURPOSE: Further acceleration of DWI in diagnostic radiology is desired but challenging mainly due to low SNR in high b-value images and associated bias in quantitative ADC values. Deep learning-based reconstruction and denoising may provide a solution to address this challenge. METHODS: The effects of SNR reduction on ADC bias and variability were investigated using a commercial diffusion phantom and numerical simulations. In the phantom, performance of different reconstruction methods, including conventional parallel (SENSE) imaging, compressed sensing (C-SENSE), and compressed SENSE acceleration with an artificial intelligence deep learning-based technique (C-SENSE AI), was compared at different acceleration factors and flip angles using ROI-based analysis. ADC bias was assessed by Lin's Concordance correlation coefficient (CCC) followed by bootstrapping to calculate confidence intervals (CI). ADC random measurement error (RME) was assessed by the mean coefficient of variation (CV¯) and non-parametric statistical tests. RESULTS: The simulations predicted increasingly negative bias and loss of precision towards lower SNR. These effects were confirmed in phantom measurements of increasing acceleration, for which CCC decreased from 0.947 to 0.279 and CV¯ increased from 0.043 to 0.439, and of decreasing flip angle, for which CCC decreased from 0.990 to 0.063 and CV¯ increased from 0.037 to 0.508. At high acceleration and low flip angle, C-SENSE AI reconstruction yielded best denoised ADC maps. For the lowest investigated flip angle, CCC = {0.630, 0.771 and 0.987} and CV¯={0.508, 0.426 and 0.254} were obtained for {SENSE, C-SENSE, C-SENSE AI}, the improvement by C-SENSE AI being significant as compared to the other methods (CV: p = 0.033 for C-SENSE AI vs. C-SENSE and p < 0.001 for C-SENSE AI vs. SENSE; CCC: non-overlapping CI between reconstruction methods). For the highest investigated acceleration factor, CCC = {0.479,0.926,0.960} and CV¯={0.519,0.119,0.118} were found, confirming the reduction of bias and RME by C-SENSE AI as compared to C-SENSE (by trend) and to SENSE (CV: p < 0.001; CCC: non-overlapping CI). CONCLUSION: ADC bias and random measurement error in DWI at low SNR, typically associated with scan acceleration, can be effectively reduced by deep-learning based C-SENSE AI reconstruction.
Asunto(s)
Aprendizaje Profundo , Imagen de Difusión por Resonancia Magnética , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Relación Señal-Ruido , Imagen de Difusión por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Humanos , Reproducibilidad de los Resultados , Algoritmos , Simulación por ComputadorRESUMEN
Quantitative MRI techniques such as T2 and T1ρ mapping are beneficial in evaluating knee joint pathologies; however, long acquisition times limit their clinical adoption. MIXTURE (Multi-Interleaved X-prepared Turbo Spin-Echo with IntUitive RElaxometry) provides a versatile turbo spin-echo (TSE) platform for simultaneous morphologic and quantitative joint imaging. Two MIXTURE sequences were designed along clinical requirements: "MIX1", combining proton density (PD)-weighted fat-saturated (FS) images and T2 mapping (acquisition time: 4:59 min), and "MIX2", combining T1-weighted images and T1ρ mapping (6:38 min). MIXTURE sequences and their reference 2D and 3D TSE counterparts were acquired from ten human cadaveric knee joints at 3.0 T. Contrast, contrast-to-noise ratios, and coefficients of variation were comparatively evaluated using parametric tests. Clinical radiologists (n = 3) assessed diagnostic quality as a function of sequence and anatomic structure using five-point Likert scales and ordinal regression, with a significance level of α = 0.01. MIX1 and MIX2 had at least equal diagnostic quality compared to reference sequences of the same image weighting. Contrast, contrast-to-noise ratios, and coefficients of variation were largely similar for the PD-weighted FS and T1-weighted images. In clinically feasible scan times, MIXTURE sequences yield morphologic, TSE-based images of diagnostic quality and quantitative parameter maps with additional insights on soft tissue composition and ultrastructure.
RESUMEN
Biohybrid tissue-engineered vascular grafts (TEVGs) promise long-term durability due to their ability to adapt to hosts' needs. However, the latter calls for sensitive non-invasive imaging approaches to longitudinally monitor their functionality, integrity, and positioning. Here, we present an imaging approach comprising the labeling of non-degradable and degradable TEVGs' components for their in vitro and in vivo monitoring by hybrid 1H/19F MRI. TEVGs (inner diameter 1.5 mm) consisted of biodegradable poly(lactic-co-glycolic acid) (PLGA) fibers passively incorporating superparamagnetic iron oxide nanoparticles (SPIONs), non-degradable polyvinylidene fluoride scaffolds labeled with highly fluorinated thermoplastic polyurethane (19F-TPU) fibers, a smooth muscle cells containing fibrin blend, and endothelial cells. 1H/19F MRI of TEVGs in bioreactors, and after subcutaneous and infrarenal implantation in rats, revealed that PLGA degradation could be faithfully monitored by the decreasing SPIONs signal. The 19F signal of 19F-TPU remained constant over weeks. PLGA degradation was compensated by cells' collagen and α-smooth-muscle-actin deposition. Interestingly, only TEVGs implanted on the abdominal aorta contained elastin. XTT and histology proved that our imaging markers did not influence extracellular matrix deposition and host immune reaction. This concept of non-invasive longitudinal assessment of cardiovascular implants using 1H/19F MRI might be applicable to various biohybrid tissue-engineered implants, facilitating their clinical translation.
Asunto(s)
Prótesis Vascular , Imagen por Resonancia Magnética , Copolímero de Ácido Poliláctico-Ácido Poliglicólico , Ingeniería de Tejidos , Andamios del Tejido , Animales , Andamios del Tejido/química , Ingeniería de Tejidos/métodos , Imagen por Resonancia Magnética/métodos , Copolímero de Ácido Poliláctico-Ácido Poliglicólico/química , Ratas , Humanos , Masculino , Ácido Poliglicólico/química , Ácido Láctico/química , Poliuretanos/química , Miocitos del Músculo Liso/citología , Materiales Biocompatibles/química , Ratas Sprague-Dawley , Nanopartículas Magnéticas de Óxido de Hierro/químicaRESUMEN
OBJECTIVES: Optical fluorescence imaging can track the biodistribution of fluorophore-labeled drugs, nanoparticles, and antibodies longitudinally. In hybrid computed tomography-fluorescence tomography (CT-FLT), CT provides the anatomical information to generate scattering and absorption maps supporting a 3-dimensional reconstruction from the raw optical data. However, given the CT's limited soft tissue contrast, fluorescence reconstruction and quantification can be inaccurate and not sufficiently detailed. Magnetic resonance imaging (MRI) can overcome these limitations and extend the options for tissue characterization. Thus, we aimed to establish a hybrid CT-MRI-FLT approach for whole-body imaging and compared it with CT-FLT. MATERIALS AND METHODS: The MRI-based hybrid imaging approaches were established first by scanning a water and coconut oil-filled phantom, second by quantifying Cy7 concentrations of inserts in dead mice, and finally by analyzing the biodistribution of AF750-labeled immunoglobulins (IgG, IgA) in living SKH1 mice. Magnetic resonance imaging, acquired with a fat-water-separated mDixon sequence, CT, and FLT were co-registered using markers in the mouse holder frame filled with white petrolatum, which was solid, stable, and visible in both modalities. RESULTS: Computed tomography-MRI fusion was confirmed by comparing the segmentation agreement using Dice scores. Phantom segmentations showed good agreement, after correction for gradient linearity distortion and chemical shift. Organ segmentations in dead and living mice revealed adequate agreement for fusion. Marking the mouse holder frame and the successful CT-MRI fusion enabled MRI-FLT as well as CT-MRI-FLT reconstructions. Fluorescence tomography reconstructions supported by CT, MRI, or CT-MRI were comparable in dead mice with 60 pmol fluorescence inserts at different locations. Although standard CT-FLT reconstruction only considered general values for soft tissue, skin, lung, fat, and bone scattering, MRI's more versatile soft tissue contrast enabled the additional consideration of liver, kidneys, and brain. However, this did not change FLT reconstructions and quantifications significantly, whereas for extending scattering maps, it was important to accurately segment the organs and the entire mouse body. The various FLT reconstructions also provided comparable results for the in vivo biodistribution analyses with fluorescent immunoglobulins. However, MRI additionally enabled the visualization of gallbladder, thyroid, and brain. Furthermore, segmentations of liver, spleen, and kidney were more reliable due to better-defined contours than in CT. Therefore, the improved segmentations enabled better assignment of fluorescence signals and more differentiated conclusions with MRI-FLT. CONCLUSIONS: Whole-body CT-MRI-FLT was implemented as a novel trimodal imaging approach, which allowed to more accurately assign fluorescence signals, thereby significantly improving pharmacokinetic analyses.
RESUMEN
Accurate and automatic segmentation of fibroglandular tissue in breast MRI screening is essential for the quantification of breast density and background parenchymal enhancement. In this retrospective study, we developed and evaluated a transformer-based neural network for breast segmentation (TraBS) in multi-institutional MRI data, and compared its performance to the well established convolutional neural network nnUNet. TraBS and nnUNet were trained and tested on 200 internal and 40 external breast MRI examinations using manual segmentations generated by experienced human readers. Segmentation performance was assessed in terms of the Dice score and the average symmetric surface distance. The Dice score for nnUNet was lower than for TraBS on the internal testset (0.909 ± 0.069 versus 0.916 ± 0.067, P < 0.001) and on the external testset (0.824 ± 0.144 versus 0.864 ± 0.081, P = 0.004). Moreover, the average symmetric surface distance was higher (= worse) for nnUNet than for TraBS on the internal (0.657 ± 2.856 versus 0.548 ± 2.195, P = 0.001) and on the external testset (0.727 ± 0.620 versus 0.584 ± 0.413, P = 0.03). Our study demonstrates that transformer-based networks improve the quality of fibroglandular tissue segmentation in breast MRI compared to convolutional-based models like nnUNet. These findings might help to enhance the accuracy of breast density and parenchymal enhancement quantification in breast MRI screening.