1.
Nephrology (Carlton) ; 25(11): 865-871, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32706161

RESUMEN

AIM: Fatigue in haemodialysis (HD) patients can be captured in quality of life questionnaires and by the dialysis recovery time (DRT) question. The associations between fatigue and measured physical activity has not been explored until the present. We tested our hypothesis that the patient perception of chronic and post dialysis fatigue would be associated with lower physical activity. METHODS: This study was a cross sectional evaluation of baseline data from HD patients recruited in the HDFIT trial. Vitality scores from the Kidney Disease Quality of Life (KDQOL-36) and the dialysis recovery time (DRT) question were used as indicators of chronic and post dialysis fatigue, respectively. Granular physical activity was measured by accelerometers as part of the study protocol. RESULTS: Among 176 patients, Vitality score was 63 ± 21 and the DRT was ≤30 minutes in 57% of patients. The mean number of steps was 5288 ± 3540 in 24 hours after HD and 953 ± 617 in the 2-hour post-HD period. The multivariable analysis confirmed Vitality scores were associated with physical activity in the 24-hour post-HD period. In contrast, DRT was not associated with physical activity captured by the accelerometer in the period immediately (2 hours) after the HD session. CONCLUSION: Chronic fatigue was negatively associated with step counts, while patient perception of post-dialysis fatigue was not associated with physical activity. These patterns indicate limitations in interpretation of DRT. Since physical activity is an important component of a healthy life, our results may partially explain the associations between fatigue and poor outcomes in HD patients.


Asunto(s)
Ejercicio Físico , Fatiga/psicología , Fallo Renal Crónico/psicología , Diálisis Renal , Autoimagen , Adulto , Anciano , Estudios Transversales , Femenino , Estado de Salud , Humanos , Fallo Renal Crónico/terapia , Masculino , Persona de Mediana Edad , Calidad de Vida , Recuperación de la Función , Factores de Tiempo
2.
BMC Nephrol ; 21(1): 529, 2020 12 07.
Artículo en Inglés | MEDLINE | ID: mdl-33287719

RESUMEN

BACKGROUND: Dialysis recovery time (DRT) surveys capture the perceived time after HD to return to performing regular activities. Prior studies suggest the majority of HD patients report a DRT > 2 h. However, the profiles of and modifiable dialysis practices associated with changes in DRT relative to the start of dialysis are unknown. We hypothesized hemodialysis (HD) dose and rates of intradialytic hypotension (IDH) would associate with changes in DRT in the first years after initiating dialysis. METHODS: We analyzed data from adult HD patients who responded to a DRT survey ≤180 days from first date of dialysis (FDD) during 2014 to 2017. DRT survey was administered with annual KDQOL survey. DRT survey asks: "How long does it take you to be able to return to your normal activities after your dialysis treatment?" Answers are: < 0.5, 0.5-to-1, 1-to-2, 2-to-4, or > 4 h. An adjusted logistic regression model computed odds ratio for a change to a longer DRT (increase above DRT > 2 h) in reference to a change to a shorter DRT (decrease below DRT < 2 h, or from DRT > 4 h). Changes in DRT were calculated from incident (≤180 days FDD) to first prevalent (> 365-to- ≤ 545 days FDD) and second prevalent (> 730-to- ≤ 910 days FDD) years. RESULTS: Among 98,616 incident HD patients (age 62.6 ± 14.4 years, 57.8% male) who responded to DRT survey, a higher spKt/V in the incident period was associated with 13.5% (OR = 0.865; 95%CI 0.801-to-0.935) lower risk of a change to a longer DRT in the first-prevalent year. A higher number of HD treatments with IDH episodes per month in the incident period was associated with a 0.8% (OR = 1.008; 95%CI 1.001-to-1.015) and 1.6% (OR = 1.016; 95%CI 1.006-to-1.027) higher probability of a change to a longer DRT in the first- and second-prevalent years, respectively. Consistently, an increased in incidence of IDH episodes/months was associated to a change to a longer DRT over time. CONCLUSIONS: Incident patients who had higher spKt/V and less sessions with IDH episodes had a lower likelihood of changing to a longer DRT in first year of HD. Dose optimization strategies with cardiac stability in fluid removal should be tested.


Asunto(s)
Hipotensión/epidemiología , Fallo Renal Crónico/terapia , Recuperación de la Función , Diálisis Renal/métodos , Anciano , Índice de Masa Corporal , Femenino , Humanos , Hipotensión/etiología , Modelos Logísticos , Masculino , Persona de Mediana Edad , Diálisis Renal/efectos adversos , Factores Sexuales , Encuestas y Cuestionarios , Factores de Tiempo
3.
Geobiology ; 22(1): e12577, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37750460

RESUMEN

Unveiling the tempo and mode of animal evolution is necessary to understand the links between environmental changes and biological innovation. Although the earliest unambiguous metazoan fossils date to the late Ediacaran period, molecular clock estimates agree that the last common ancestor (LCA) of all extant animals emerged ~850 Ma, in the Tonian period, before the oldest evidence for widespread ocean oxygenation at ~635-560 Ma in the Ediacaran period. Metazoans are aerobic organisms, that is, they are dependent on oxygen to survive. In low-oxygen conditions, most animals have an evolutionarily conserved pathway for maintaining oxygen homeostasis that triggers physiological changes in gene expression via the hypoxia-inducible factor (HIFa). However, here we confirm the absence of the characteristic HIFa protein domain responsible for the oxygen sensing of HIFa in sponges and ctenophores, indicating the LCA of metazoans lacked the functional protein domain as well, and so could have maintained their transcription levels unaltered under the very low-oxygen concentrations of their environments. Using Bayesian relaxed molecular clock dating, we inferred that the ancestral gene lineage responsible for HIFa arose in the Mesoproterozoic Era, ~1273 Ma (Credibility Interval 957-1621 Ma), consistent with the idea that important genetic machinery associated with animals evolved much earlier than the LCA of animals. Our data suggest at least two duplication events in the evolutionary history of HIFa, which generated three vertebrate paralogs, products of the two successive whole-genome duplications that occurred in the vertebrate LCA. Overall, our results support the hypothesis of a pre-Tonian emergence of metazoans under low-oxygen conditions, and an increase in oxygen response elements during animal evolution.


Asunto(s)
Oxígeno , Vertebrados , Animales , Oxígeno/metabolismo , Teorema de Bayes , Vertebrados/metabolismo , Hipoxia , Filogenia , Evolución Biológica , Fósiles
4.
Sci Rep ; 14(1): 14916, 2024 06 28.
Artículo en Inglés | MEDLINE | ID: mdl-38942912

RESUMEN

The Ediacaran-Cambrian transition documents a critical stage in the diversification of animals. The global fossil record documents the appearance of cloudinomorphs and other shelled tubular organisms followed by non-biomineralized small carbonaceous fossils and by the highly diversified small shelly fossils between ~ 550 and 530 Ma. Here, we report diverse microfossils in thin sections and hand samples from the Ediacaran Bocaina Formation, Brazil, separated into five descriptive categories: elongate solid structures (ES); elongate filled structures (EF); two types of equidimensional structures (EQ 1 and 2) and elongate hollow structures with coiled ends (CE). These specimens, interpreted as diversified candidate metazoans, predate the latest Ediacaran biomineralized index macrofossils of the Cloudina-Corumbella-Namacalathus biozone in the overlying Tamengo Formation. Our new carbonate U-Pb ages for the Bocaina Formation, position this novel fossil record at 571 ± 9 Ma (weighted mean age). Thus, our data point to diversification of metazoans, including biomineralized specimens reminiscent of sections of cloudinids, protoconodonts, anabaritids, and hyolithids, in addition to organo-phosphatic surficial coverings of animals, demonstrably earlier than the record of the earliest known skeletonized metazoan fossils.


Asunto(s)
Fósiles , Animales , Brasil , Exoesqueleto/anatomía & histología , Exoesqueleto/química , Evolución Biológica , Paleontología/métodos
5.
Artif Organs ; 37(11): 942-5, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24219168

RESUMEN

A new model of centrifugal blood pump for temporary ventricular assist devices has been developed and evaluated. The design of the device is based on centrifugal pumping principles and the usage of ceramic bearings, resulting in a pump with reduced priming (35 ± 2 mL) that can be applied for up to 30 days. Computational fluid dynamic (CFD) analysis is an efficient tool to optimize flow path geometry, maximize hydraulic performance, and minimize shear stress, consequently decreasing hemolysis. Initial studies were conducted by analyzing flow behavior with different impellers, aiming to determine the best impeller design. After CFD studies, rapid prototyping technology was used for production of pump prototypes with three different impellers. In vitro experiments were performed with those prototypes, using a mock loop system composed of Tygon tubes, oxygenator, digital flow meter, pressure monitor, electronic driver, and adjustable clamp for flow control, filled with a solution (1/3 water, 1/3 glycerin, 1/3 alcohol) simulating blood viscosity and density. Flow-versus-pressure curves were obtained for rotational speeds of 1000, 1500, 2000, 2500, and 3000 rpm. As the next step, the CFD analysis and hydrodynamic performance results will be compared with the results of flow visualization studies and hemolysis tests.


Asunto(s)
Corazón Auxiliar , Centrifugación , Cerámica/química , Corazón Auxiliar/efectos adversos , Hemólisis , Humanos , Hidrodinámica , Diseño de Prótesis
6.
Artif Organs ; 37(11): 946-9, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24237361

RESUMEN

An implantable centrifugal blood pump (ICBP) is being developed to be used as a ventricular assist device (VAD) in patients with severe cardiovascular diseases. The ICBP system is composed of a centrifugal pump, a motor, a controller, and a power supply. The electricity source provides power to the controller and to a motor that moves the pump's rotor through magnetic coupling. The centrifugal pump is composed of four parts: external conical house, external base, impeller, and impeller base. The rotor is supported by a pivot bearing system, and its impeller base is responsible for sheltering four permanent magnets. A hybrid cardiovascular simulator (HCS) was used to evaluate the ICBP's performance. A heart failure (HF) (when the heart increases beat frequency to compensate for decrease in blood flow) was simulated in the HCS. The main objective of this work is to analyze changes in physiological parameters such as cardiac output, blood pressure, and heart rate in three situations: healthy heart, HF, and HF with left circulatory assistance by ICBP. The results showed that parameters such as aortic pressure and cardiac output affected by the HF situation returned to normal values when the ICBP was connected to the HCS. In conclusion, the test results showed satisfactory performance for the ICBP as a VAD.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Corazón/fisiología , Corazón/fisiopatología , Circulación Asistida , Insuficiencia Cardíaca/fisiopatología , Frecuencia Cardíaca , Humanos , Modelos Cardiovasculares , Diseño de Prótesis
7.
Artif Organs ; 37(11): 950-3, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24251772

RESUMEN

The Apico Aortic Blood Pump (AABP) is a centrifugal continuous flow left ventricular assist device (LVAD) with ceramic bearings. The device is in the initial development phase and is being designed to be attached directly to the left ventricular apex by introducing an inlet cannula. This paper reports results from in vitro experiments. In order to evaluate implantation procedures and device dimensioning, in vitro experiments included an anatomic positioning study for the analysis of surgical implantation procedure and device dimensions and positioning that was performed using the body of a pig. The results revealed no damage caused by the device, and the surgical implantation procedure was considered feasible. Hydrodynamic performance curves were obtained to verify the applicability of the device as an LVAD, showing adequate performance. Mechanical blood trauma was analyzed through 6-h hemolysis tests, with total pressure head of 100 mm Hg and flow of 5 L/min. Mean normalized index of hemolysis was 0.009 g/100 L (±0.002 g/100 L). Studies using a hybrid cardiovascular simulator were conducted for three types of circulatory conditions: normal healthy conditions, concentric hypertrophic heart failure (CHHF), and CHHF with AABP assistance. Analysis of cardiovascular parameters under those three conditions demonstrated that when the AABP was assisting the system, parameters under CHHF conditions went back to normal healthy values, indicating the AABP's effectiveness as CHHF therapy. Our preliminary results indicate that it is feasible to use the AABP as a LVAD. The next steps include long-term in vivo experiments.


Asunto(s)
Ventrículos Cardíacos/cirugía , Corazón Auxiliar , Animales , Cerámica/química , Corazón Auxiliar/efectos adversos , Hemólisis , Humanos , Hidrodinámica , Modelos Cardiovasculares , Diseño de Prótesis , Porcinos
8.
Artif Organs ; 37(11): 954-7, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24251773

RESUMEN

The Spiral Pump (SP), a centrifugal blood pump for cardiopulmonary bypass (CPB), has been developed at the Dante Pazzanese Institute of Cardiology/Adib Jatene Foundation laboratories, with support from Sintegra Company (Pompeia, Brazil). The SP is a disposable pump with an internal rotor-a conically shaped fuse with double entrance threads. This rotor is supported by two ball bearings, attached to a stainless steel shaft fixed to the housing base. Worm gears provide axial motion to the blood column, and the rotational motion of the conically shaped impeller generates a centrifugal pumping effect, improving pump efficiency without increasing hemolysis. In vitro tests were performed to evaluate the SP's hydrodynamic performance, and in vivo experiments were performed to evaluate hemodynamic impact during usual CPB. A commercially available centrifugal blood pump was used as reference. In vivo experiments were conducted in six male pigs weighing between 60 and 90 kg, placed on CPB for 6 h each. Blood samples were collected just before CPB (T0) and after every hour of CPB (T1-T6) for hemolysis determination and laboratory tests (hematological and biochemical). Values of blood pressure, mean flow, pump rotational speed, and corporeal temperature were recorded. Also, ergonomic conditions were recorded: presence of noise, difficulty in removing air bubbles, trouble in installing the pump in the drive module (console), and difficulties in mounting the CPB circuit. Comparing the laboratory and hemolysis results for the SP with those of the reference pump, we can conclude that there is no significant difference between the two devices. In addition, reports made by medical staff and perfusionists described a close similarity between the two devices. During in vivo experiments, the SP maintained blood flow and pressure at physiological levels, consistent with those applied in cardiac surgery with CPB, without presenting any malfunction. Also, the SP needed lower rotational speed to obtain average blood flow and pressure, compared with the reference pump.


Asunto(s)
Circulación Asistida/instrumentación , Puente Cardiopulmonar/instrumentación , Animales , Circulación Asistida/efectos adversos , Puente Cardiopulmonar/efectos adversos , Diseño de Equipo , Hemólisis , Hidrodinámica , Masculino , Porcinos
9.
J Surg Case Rep ; 2023(4): rjad193, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37082649

RESUMEN

Encapsulating peritoneal sclerosis (EPS) is a rare and debilitating condition. A fibrocollagenous membrane, which promotes encasement of the small intestine leaving a cocoon-like appearance, takes place. It is mainly associated with peritoneal infections, medications, peritoneal dialysis and systemic inflammatory diseases. Diagnosis is based on clinical history, intestinal obstruction and imaging exam. We report a case of EPS in a 68-year-old man with a medical history of liver transplantation and peritoneal dialysis, complaining of obstructive bowel symptoms.

10.
Geobiology ; 20(3): 333-345, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34766436

RESUMEN

The Neoproterozoic included changes in oceanic redox conditions, the configuration of continents and climate, extreme ice ages (Sturtian and Marinoan), and the rise of complex life forms. A much-debated topic in geobiology concerns the influence of atmospheric oxygenation on Earth and the origin and diversification of animal lineages, with the most widely popularized hypotheses relying on causal links between oxygen levels and the rise of animals. The vast majority of extant animals use aerobic metabolism for growth and homeostasis; hence, the binding and transportation of oxygen represent a vital physiological task. Considering the blood pigment hemocyanin (Hc) is present in sponges and ctenophores, and likely to be present in the common ancestor of animals, we investigated the evolution and date of Hc emergence using bioinformatics approaches on both transcriptomic and genomic data. Bayesian molecular dating suggested that the ancestral animal Hc gene arose approximately 881 Ma during the Tonian Period (1000-720 Ma), prior to the extreme glaciation events of the Cryogenian Period (720-635 Ma). This result is corroborated by a recently discovered fossil of a putative sponge ~890 Ma and modern molecular dating for the origin of metazoans of ~1,000-650 Ma (but does contradict previous inferences regarding the origin of Hc ~700-600 Ma). Our data reveal that crown-group animals already possessed hemocyanin-like blood pigments, which may have enhanced the oxygen-carrying capacity of these animals in hypoxic environments at that time or acted in the transport of hormones, detoxification of heavy metals, and immunity pathways.


Asunto(s)
Fósiles , Hemocianinas , Animales , Teorema de Bayes , Océanos y Mares , Oxígeno/análisis , Filogenia
11.
Artif Organs ; 35(5): 454-8, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21595711

RESUMEN

This article presents improvement on a physical cardiovascular simulator (PCS) system. Intraventricular pressure versus intraventricular volume (PxV) loop was obtained to evaluate performance of a pulsatile chamber mimicking the human left ventricle. PxV loop shows heart contractility and is normally used to evaluate heart performance. In many heart diseases, the stroke volume decreases because of low heart contractility. This pathological situation must be simulated by the PCS in order to evaluate the assistance provided by a ventricular assist device (VAD). The PCS system is automatically controlled by a computer and is an auxiliary tool for VAD control strategies development. This PCS system is according to a Windkessel model where lumped parameters are used for cardiovascular system analysis. Peripheral resistance, arteries compliance, and fluid inertance are simulated. The simulator has an actuator with a roller screw and brushless direct current motor, and the stroke volume is regulated by the actuator displacement. Internal pressure and volume measurements are monitored to obtain the PxV loop. Left chamber internal pressure is directly obtained by pressure transducer; however, internal volume has been obtained indirectly by using a linear variable differential transformer, which senses the diaphragm displacement. Correlations between the internal volume and diaphragm position are made. LabVIEW integrates these signals and shows the pressure versus internal volume loop. The results that have been obtained from the PCS system show PxV loops at different ventricle elastances, making possible the simulation of pathological situations. A preliminary test with a pulsatile VAD attached to PCS system was made.


Asunto(s)
Cardiopatías/fisiopatología , Hemodinámica , Modelos Cardiovasculares , Volumen Sistólico , Función Ventricular Izquierda , Presión Ventricular , Adaptabilidad , Cardiopatías/terapia , Corazón Auxiliar , Humanos , Ensayo de Materiales , Microcomputadores , Contracción Miocárdica , Diseño de Prótesis , Flujo Pulsátil , Factores de Tiempo , Transductores de Presión , Resistencia Vascular
12.
Artif Organs ; 35(5): 437-42, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21595708

RESUMEN

An implantable centrifugal blood pump has been developed with original features for a left ventricular assist device. This pump is part of a multicenter and international study with the objective to offer simple, affordable, and reliable devices to developing countries. Previous computational fluid dynamics investigations and wear evaluation in bearing system were performed followed by prototyping and in vitro tests. In addition, previous blood tests for assessment of normalized index of hemolysis show results of 0.0054±2.46 × 10⁻³ mg/100 L. An electromechanical actuator was tested in order to define the best motor topology and controller configuration. Three different topologies of brushless direct current motor (BLDCM) were analyzed. An electronic driver was tested in different situations, and the BLDCM had its mechanical properties tested in a dynamometer. Prior to evaluation of performance during in vivo animal studies, anatomical studies were necessary to achieve the best configuration and cannulation for left ventricular assistance. The results were considered satisfactory, and the next step is to test the performance of the device in vivo.


Asunto(s)
Corazón Auxiliar , Hemodinámica , Implantación de Prótesis , Función Ventricular Izquierda , Animales , Fenómenos Biomecánicos , Brasil , Bovinos , Masculino , Ensayo de Materiales , Diseño de Prótesis
13.
Artif Organs ; 35(5): 443-7, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21595709

RESUMEN

A new model of blood pump for cardiopulmonary bypass (CPB) application has been developed and evaluated in our laboratories. Inside the pump housing is a spiral impeller that is conically shaped and has threads on its surface. Worm gears provide an axial motion of the blood column. Rotational motion of the conical shape generates a centrifugal pumping effect and improves pumping performance. One annular magnet with six poles is inside the impeller, providing magnetic coupling to a brushless direct current motor. In order to study the pumping performance, a mock loop system was assembled. Mock loop was composed of Tygon tubes (Saint-Gobain Corporation, Courbevoie, France), oxygenator, digital flowmeter, pressure monitor, electronic driver, and adjustable clamp for flow control. Experiments were performed on six prototypes with small differences in their design. Each prototype was tested and flow and pressure data were obtained for rotational speed of 1000, 1500, 2000, 2500, and 3000 rpm. Hemolysis was studied using pumps with different internal gap sizes (1.35, 1.45, 1.55, and 1.7 mm). Hemolysis tests simulated CPB application with flow rate of 5 L/min against total pressure head of 350 mm Hg. The results from six prototypes were satisfactory, compared to the results from the literature. However, prototype #6 showed the best results. Best hemolysis results were observed with a gap of 1.45 mm, and showed a normalized index of hemolysis of 0.013 g/100 L. When combined, axial and centrifugal pumping principles produce better hydrodynamic performance without increasing hemolysis.


Asunto(s)
Puente Cardiopulmonar/instrumentación , Corazón Auxiliar , Hemólisis , Animales , Velocidad del Flujo Sanguíneo , Puente Cardiopulmonar/efectos adversos , Bovinos , Corazón Auxiliar/efectos adversos , Hemorreología , Hidrodinámica , Magnetismo , Ensayo de Materiales , Presión , Diseño de Prótesis , Rotación
14.
Sci Rep ; 11(1): 15744, 2021 08 03.
Artículo en Inglés | MEDLINE | ID: mdl-34344935

RESUMEN

The biological toolkits for aerobic respiration were critical for the rise and diversification of early animals. Aerobic life forms generate ATP through the oxidation of organic molecules in a process known as Krebs' Cycle, where the enzyme isocitrate dehydrogenase (IDH) regulates the cycle's turnover rate. Evolutionary reconstructions and molecular dating of proteins related to oxidative metabolism, such as IDH, can therefore provide an estimate of when the diversification of major taxa occurred, and their coevolution with the oxidative state of oceans and atmosphere. To establish the evolutionary history and divergence time of NAD-dependent IDH, we examined transcriptomic data from 195 eukaryotes (mostly animals). We demonstrate that two duplication events occurred in the evolutionary history of NAD-IDH, one in the ancestor of eukaryotes approximately at 1967 Ma, and another at 1629 Ma, both in the Paleoproterozoic Era. Moreover, NAD-IDH regulatory subunits ß and γ are exclusive to metazoans, arising in the Mesoproterozoic. Our results therefore support the concept of an ''earlier-than-Tonian'' diversification of eukaryotes and the pre-Cryogenian emergence of a metazoan IDH enzyme.


Asunto(s)
Eucariontes/enzimología , Evolución Molecular , Isocitrato Deshidrogenasa/metabolismo , NADP/metabolismo , NAD/metabolismo , Transcriptoma , Animales , Respiración de la Célula , Ciclo del Ácido Cítrico , Eucariontes/genética , Eucariontes/crecimiento & desarrollo , Isocitrato Deshidrogenasa/genética , Filogenia
15.
Artif Organs ; 32(4): 329-33, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18370949

RESUMEN

A new dual impeller centrifugal blood pump has been developed as a research collaboration between Baylor College of Medicine and Institute Dante Pazzanese of Cardiology for long-term left ventricle assist device (LVAD). A design feature of this new pump is a dual impeller that aims to minimize a stagnant flow pattern around the inlet port. Several different materials were tested in order to adopt a double pivot bearing design originally developed by Prof. Dr. Yukihiko Nosé from Baylor College of Medicine. Hydraulic performance tests were conducted with two different inlet ports' angle configurations 30 degrees and 45 degrees . Pump with inlet port angle of 45 degrees achieved best values of pressure ahead and flow after 1800 rpm. Preliminary hemolysis tests were conducted using human blood. The pump showed good performance results and no alarming trace of hemolysis, proving to be a feasible long-term LVAD.


Asunto(s)
Materiales Biocompatibles , Cerámica/química , Corazón Auxiliar/efectos adversos , Hemólisis , Polímeros/química , Centrifugación , Diseño de Equipo , Estudios de Factibilidad , Hemorreología , Humanos , Ensayo de Materiales , Proyectos Piloto , Presión , Rotación , Estrés Mecánico , Factores de Tiempo
16.
Sci Rep ; 7(1): 5482, 2017 07 14.
Artículo en Inglés | MEDLINE | ID: mdl-28710440

RESUMEN

At the Ediacaran/Cambrian boundary, ecosystems witnessed an unparalleled biological innovation: the appearance of shelled animals. Here, we report new paleoecological and paleobiological data on Cloudina, which was one of the most abundant shelled animals at the end of the Ediacaran. We report the close association of Cloudina tubes with microbial mat textures as well as organic-rich material, syndepositional calcite and goethite cement between their flanges, thus reinforcing the awareness of metazoan/microorganism interactions at the end of the Ediacaran. The preservation of in situ tubes suggests a great plasticity of substrate utilization, with evidence of different life modes and avoidance behavior. Geochemical analysis revealed walls composed of two secondary laminae and organic sheets. Some walls presented boreholes that are here described as predation marks. Taken together, these data add further information regarding the structuring of shelled animal communities in marine ecosystems.


Asunto(s)
Exoesqueleto/fisiología , Biomineralización/fisiología , Ecosistema , Exoesqueleto/anatomía & histología , Animales , Brasil , Carbonato de Calcio/química , Fósiles , Modelos Biológicos , Espectrometría Raman , Factores de Tiempo
17.
Nat Ecol Evol ; 1(10): 1455-1464, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29185521

RESUMEN

The evolutionary events during the Ediacaran-Cambrian transition (~541 Myr ago) are unparalleled in Earth history. The fossil record suggests that most extant animal phyla appeared in a geologically brief interval, with the oldest unequivocal bilaterian body fossils found in the Early Cambrian. Molecular clocks and biomarkers provide independent estimates for the timing of animal origins, and both suggest a cryptic Neoproterozoic history for Metazoa that extends considerably beyond the Cambrian fossil record. We report an assemblage of ichnofossils from Ediacaran-Cambrian siltstones in Brazil, alongside U-Pb radioisotopic dates that constrain the age of the oldest specimens to 555-542 Myr. X-ray microtomography reveals three-dimensionally preserved traces ranging from 50 to 600 µm in diameter, indicative of small-bodied, meiofaunal tracemakers. Burrow morphologies suggest they were created by a nematoid-like organism that used undulating locomotion to move through the sediment. This assemblage demonstrates animal-sediment interactions in the latest Ediacaran period, and provides the oldest known fossil evidence for meiofaunal bilaterians. Our discovery highlights meiofaunal ichnofossils as a hitherto unexplored window for tracking animal evolution in deep time, and reveals that both meiofaunal and macrofaunal bilaterians began to explore infaunal niches during the late Ediacaran.


Asunto(s)
Evolución Biológica , Fósiles/anatomía & histología , Invertebrados/anatomía & histología , Animales , Brasil , Paleontología
18.
PLoS One ; 10(3): e0114219, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25822998

RESUMEN

The Ediacaran fossil Corumbella is important because it is hypothesized to be a scyphozoan cnidarian, and thus might be one of the rare examples of bona fide Neoproterozoic animals. Unfortunately, its mode of life, style of skeletonization, and taxonomic affinity have been very controversial. Here, we use X-ray micro-CT, SEM, and taphonomic analysis to compare preservational modes of Corumbella, in order to better understand the symmetry, mode of construction, preservational style, and taxonomy of this group. Results suggest that articulated and disarticulated specimens of Corumbella from the Ediacaran of Brazil, Paraguay, and the United States, although sometimes preserved very differently, represent the same taxon--Corumbella werneri. Corumbellids had a thick but flexible theca and probably lived with their basalmost part anchored in the sediment, much like Conotubus. When considered together, these results suggest that Corumbella was one of the first animals to build a skeleton, employing a lamellar microfabric similar to conulariids.


Asunto(s)
Fósiles , Gastrópodos , Esqueleto , Animales , Brasil , Gastrópodos/anatomía & histología , Gastrópodos/clasificación , Geografía , Paleontología , Microtomografía por Rayos X
19.
Rev Bras Cir Cardiovasc ; 29(3): 330-7, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25372905

RESUMEN

OBJECTIVE: The objective of this paper is to present the results from Spiral Pump clinical trial after design modifications performed at its previous project. This pump applies axial end centrifugal hydraulic effects for blood pumping during cardiopulmonary bypass for patients under cardiac surgery. METHODS: This study was performed in 52 patients (51% males), between 20 to 80 (67±14.4) years old weighing 53 to 102 (71.7±12.6) kg, mostly under myocardial revascularization surgery (34.6%) and valvular surgery (32.8%). Besides the routine evaluation of the data observed in these cases, we monitored pump rotational speed, blood flow, cardiopulmonary bypass duration, urine free hemoglobin for blood cell trauma analysis (+ to 4+), lactate desidrogenase (UI/L), fibrinogen level (mg/dL) and platelet count (nº/mm3). RESULTS: Besides maintaining appropriate blood pressure and metabolic parameters it was also observed that the Free Hemoglobin levels remained normal, with a slight increase after 90 minutes of cardiopulmonary bypass. The Lactate Dehydrogenase showed an increase, with medians varying between 550-770 IU/L, whereas the decrease in Fibrinogen showed medians of 130-100 mg/dl. The number of platelets showed a slight decrease with the medians ranging from 240,000 to 200,000/mm3. No difficulty was observed during perfusion terminations, nor were there any immediate deaths, and all patients except one, were discharged in good condition. CONCLUSION: The Spiral Pump, as blood propeller during cardiopulmonary bypass, demonstrated to be reliable and safe, comprising in a good option as original and national product for this kind of application.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/instrumentación , Puente Cardiopulmonar/instrumentación , Corazón Auxiliar/normas , Adulto , Anciano , Anciano de 80 o más Años , Procedimientos Quirúrgicos Cardíacos/métodos , Puente Cardiopulmonar/métodos , Diseño de Equipo/normas , Seguridad de Equipos , Femenino , Fibrinógeno/análisis , Humanos , L-Lactato Deshidrogenasa/sangre , Masculino , Ilustración Médica , Persona de Mediana Edad , Modelos Cardiovasculares , Recuento de Plaquetas , Reproducibilidad de los Resultados , Estadísticas no Paramétricas , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
20.
Rev Bras Cir Cardiovasc ; 26(1): 76-85, 2011.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-21881715

RESUMEN

OBJECTIVE: The objective is to present the results of the application this device in experimental animals unloading only the left ventricle. METHODS: Between June 2002 and October 2009, were implanted in 27 calfs with age between 2½ to 4 months and 80 to 100 kg of weight, with general anaesthesia and controled ventilation, by mean of left thoracotomy a cannula in the apex of VE and a lateral anastomose of a GTFE vascular graft tube in the descending portion of the thoracic aorta, both connected to the device implanted below the diaphragm in the subcutaneous (24) and intrathoracic (three). The cardiopulmonary bypass (BP) was used in five calves, and directly introduce the outflow cannula in 22. RESULTS: During the implant two and in the first hours of the post operative period (PO) three deaths were observed, one related to the device. The survival between the first and the six PO day was found in 17 calves and between day 8 and day 31 (PO) in five all caused by clinical/surgical problems, and related to the device. The hemodynamic impact by the systemic pressure analysis showed 20 to 40 mmHg increase and the laboratory parameters showed lower levels of traumatic impact to the blood and a good biocompatibility. CONCLUSIONS: This kind of research is arduous and complex where at each experiment many problems are indentified in the implantability and in the device, which are sistematic correct, to became device/procedure safe and effective.


Asunto(s)
Materiales Biocompatibles , Implantación de Prótesis de Válvulas Cardíacas/métodos , Ventrículos Cardíacos/cirugía , Corazón Auxiliar , Animales , Bovinos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica/fisiología , Modelos Animales , Modelos Cardiovasculares , Marcapaso Artificial , Estudios Prospectivos , Diseño de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA