Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-35571871

RESUMEN

The COVID-19 pandemic has accelerated methods to facilitate contactless evaluation of patients in hospital settings. By minimizing in-person contact with individuals who may have COVID-19, healthcare workers can prevent disease transmission and conserve personal protective equipment. Obtaining vital signs is a ubiquitous task that is commonly done in person by healthcare workers. To eliminate the need for in-person contact for vital sign measurement in the hospital setting, we developed Dr. Spot, a mobile quadruped robotic system. The system includes IR and RGB cameras for vital sign monitoring and a tablet computer for face-to-face medical interviewing. Dr. Spot is teleoperated by trained clinical staff to simultaneously measure the skin temperature, respiratory rate, and heart rate while maintaining social distancing from patients and without removing their mask. To enable accurate, contactless measurements on a mobile system without a static black body as reference, we propose novel methods for skin temperature compensation and respiratory rate measurement at various distances between the subject and the cameras, up to 5 m. Without compensation, the skin temperature MAE is 1.3°C. Using the proposed compensation method, the skin temperature MAE is reduced to 0.3°C. The respiratory rate method can provide continuous monitoring with a MAE of 1.6 BPM in 30 s or rapid screening with a MAE of 2.1 BPM in 10 s. For the heart rate estimation, our system is able to achieve a MAE less than 8 BPM in 10 s measured in arbitrary indoor light conditions at any distance below 2 m.

2.
J Control Release ; 343: 31-42, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34998917

RESUMEN

Glycemic control through titration of insulin dosing remains the mainstay of diabetes mellitus treatment. Insulin therapy is generally divided into dosing with long- and short-acting insulin, where long-acting insulin provides basal coverage and short-acting insulin supports glycemic excursions associated with eating. The dosing of short-acting insulin often involves several steps for the user including blood glucose measurement and integration of potential carbohydrate loads to inform safe and appropriate dosing. The significant burden placed on the user for blood glucose measurement and effective carbohydrate counting can manifest in substantial effects on adherence. Through the application of computer vision, we have developed a smartphone-based system that is able to detect the carbohydrate load of food by simply taking a single image of the food and converting that information into a required insulin dose by incorporating a blood glucose measurement. Moreover, we report the development of comprehensive all-in-one insulin delivery systems that streamline all operations that peripheral devices require for safe insulin administration, which in turn significantly reduces the complexity and time required for titration of insulin. The development of an autonomous system that supports maximum ease and accuracy of insulin dosing will transform our ability to more effectively support patients with diabetes.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulina , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Insulina de Acción Corta/uso terapéutico
3.
Sci Adv ; 7(48): eabj4624, 2021 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-34826238

RESUMEN

Diurnal variation in enzymes, hormones, and other biological mediators has long been recognized in mammalian physiology. Developments in pharmacobiology over the past few decades have shown that timing drug delivery can enhance drug efficacy. Here, we report the development of a battery-free, refillable, subcutaneous, and trocar-compatible implantable system that facilitates chronotherapy by enabling tight control over the timing of drug administration in response to external mechanical actuation. The external wearable system is coupled to a mobile app to facilitate control over dosing time. Using this system, we show the efficacy of bromocriptine on glycemic control in a diabetic rat model. We also demonstrate that antihypertensives can be delivered through this device, which could have clinical applications given the recognized diurnal variation of hypertension-related complications. We anticipate that implants capable of chronotherapy will have a substantial impact on our capacity to enhance treatment effectiveness for a broad range of chronic conditions.

4.
BMJ Open ; 10(7): e039120, 2020 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-32641368

RESUMEN

OBJECTIVE: To develop and test a new reusable, sterilisable N95 filtering facepiece respirator (FFR)-comparable face mask, known as the Injection Molded Autoclavable, Scalable, Conformable (iMASC) system, given the dire need for personal protective equipment within healthcare settings during the COVID-19 pandemic. DESIGN: Single-arm feasibility study. SETTING: Emergency department and outpatient oncology clinic. PARTICIPANTS: Healthcare workers who have previously undergone N95 fit testing. INTERVENTIONS: Fit testing of new iMASC system. PRIMARY AND SECONDARY OUTCOME MEASURES: Primary outcome is success of fit testing using an Occupational Safety and Health Administration (OSHA)-approved testing method, and secondary outcomes are user experience with fit, breathability and filter replacement. RESULTS: Twenty-four subjects were recruited to undergo fit testing, and the average age of subjects was 41 years (range of 21-65 years) with an average body mass index of 26.5 kg/m2. The breakdown of participants by profession was 46% nurses (n=11), 21% attending physicians (n=5), 21% resident physicians (n=5) and 12% technicians (n=3). Of these participants, four did not perform the fit testing due to the inability to detect saccharin solution on premask placement sensitivity test, lack of time and inability to place mask over hair. All participants (n=20) who performed the fit test were successfully fitted for the iMASC system using an OSHA-approved testing method. User experience with the iMASC system, as evaluated using a Likert scale with a score of 1 indicating excellent and a score of 5 indicating very poor, demonstrated an average fit score of 1.75, breathability of 1.6, and ease of replacing the filter on the mask was scored on average as 2.05. CONCLUSIONS: The iMASC system was shown to successfully fit multiple different face sizes and shapes using an OSHA-approved testing method. These data support further certification testing needed for use in the healthcare setting.


Asunto(s)
Infecciones por Coronavirus/prevención & control , Diseño de Equipo , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Pandemias/prevención & control , Neumonía Viral/prevención & control , Dispositivos de Protección Respiratoria , Elastómeros de Silicona , Adulto , Anciano , Técnicos Medios en Salud , Betacoronavirus , COVID-19 , Infecciones por Coronavirus/transmisión , Equipo Reutilizado , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermeras y Enfermeros , Médicos , Neumonía Viral/transmisión , Estudios Prospectivos , SARS-CoV-2 , Esterilización , Adulto Joven
5.
ACS Pharmacol Transl Sci ; 3(6): 1076-1082, 2020 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-33330837

RESUMEN

N95 filtering facepiece respirators (FFR) and surgical masks are essential in reducing airborne disease transmission, particularly during the COVID-19 pandemic. However, currently available FFR's and masks have major limitations, including masking facial features, waste, and integrity after decontamination. In a multi-institutional trial, we evaluated a transparent, elastomeric, adaptable, long-lasting (TEAL) respirator to evaluate success of qualitative fit test with user experience and biometric evaluation of temperature, respiratory rate, and fit of respirator using a novel sensor. There was a 100% successful fit test among participants, with feedback demonstrating excellent or good fit (90% of participants), breathability (77.5%), and filter exchange (95%). Biometric testing demonstrated significant differences between exhalation and inhalation pressures among a poorly fitting respirator, well-fitting respirator, and the occlusion of one filter of the respirator. We have designed and evaluated a transparent elastomeric respirator and a novel biometric feedback system that could be implemented in the hospital setting.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA