RESUMEN
BACKGROUND: This study aimed to investigate the knowledge, attitudes, and practices (KAP) toward cardiovascular complications among end-stage renal disease patients undergoing maintenance hemodialysis. METHODS: This web-based cross-sectional study was conducted at Guangdong Provincial People's Hospital between December 2022, and May 2023. RESULTS: A total of 545 valid questionnaires were collected, with an average age of 57.72 ± 13.47 years. The mean knowledge, attitudes and practices scores were 8.17 ± 2.9 (possible range: 0-24), 37.63 ± 3.80 (possible range: 10-50), 33.07 ± 6.10 (possible range: 10-50) respectively. Multivariate logistic regression analysis showed that patients from non-urban area had lower knowledge compared to those from urban area (odds ratio (OR) = 0.411, 95% CI: 0.262-0.644, P < 0.001). Furthermore, higher levels of education were associated with better knowledge, as indicated by OR for college and above (OR = 4.858, 95% CI: 2.483-9.504), high school/vocational school (OR = 3.457, 95% CI: 1.930-6.192), junior high school (OR = 3.300, 95% CI: 1.945-5.598), with primary school and below as reference group (all P < 0.001). Besides, better knowledge (OR = 1.220, 95% CI: 1.132-1.316, P < 0.001) and higher educational levels were independently associated with positive attitudes. Specifically, individuals with a college degree and above (OR = 2.986, 95% CI: 1.411-6.321, P = 0.004) and those with high school/vocational school education (OR = 2.418, 95% CI: 1.314-4.451, P = 0.005) have more positive attitude, with primary school and below as reference group. Next, better attitude (OR = 1.174, 95% CI: 1.107-1.246, P < 0.001) and higher education were independently associated with proactive practices. Those with college and above (OR = 2.870, 95% CI: 1.359-6.059, P = 0.006), and those with high school/vocational school education (OR = 1.886, 95% CI: 1.032-3.447, P = 0.039) had more proactive practices, with primary school and below as reference group. CONCLUSIONS: End-stage renal disease patients undergoing maintenance hemodialysis demonstrated insufficient knowledge, positive attitudes, and moderate practices regarding cardiovascular complications. Targeted interventions should prioritize improving knowledge and attitudes, particularly among patients with lower educational levels and income, to enhance the management of cardiovascular complications in end-stage renal disease.
Asunto(s)
Enfermedades Cardiovasculares , Conocimientos, Actitudes y Práctica en Salud , Fallo Renal Crónico , Diálisis Renal , Humanos , Masculino , Femenino , Diálisis Renal/psicología , Estudios Transversales , Fallo Renal Crónico/terapia , Fallo Renal Crónico/psicología , Persona de Mediana Edad , Adulto , Anciano , Encuestas y Cuestionarios , China/epidemiologíaRESUMEN
Microwaves (MWs) are applied to initialize deoxygenation of graphene oxide (GO) in the solid state and at low temperatures (â¼165 °C). The Fourier-transform infrared (FTIR) spectra of MW-reduced graphene oxide (rGO) show a significantly reduced concentration of oxygen-containing functional groups, such as carboxyl, hydroxyl and carbonyl. X-ray photoelectron spectra confirm that microwaves can promote deoxygenation of GO at relatively low temperatures. Raman spectra and TGA measurements indicate that the defect level of GO significantly decreases during the isothermal solid-state MW-reduction process at low temperatures, corresponding to an efficient recovery of the fine graphene lattice structure. Based on both deoxygenation and defect-level reduction, the resurgence of interconnected graphene-like domains contributes to a low sheet resistance (â¼7.9×10(4) Ω per square) of the MW-reduced GO on SiO(2) -coated Si substrates with an optical transparency of 92.7 % at â¼547 nm after MW reduction, indicating the ultrahigh efficiency of MW in GO reduction. Moreover, the low-temperature solid-state MW reduction is also applied in preparing flexible transparent conductive coatings on polydimethylsiloxane (PDMS) substrates. UV/Vis measurements indicate that the transparency of the thus-prepared MW-reduced GO coatings on PDMS substrates ranges from 34 to 96 %. Correspondingly, the sheet resistance of the coating ranges from 10(5) to 10(9) Ω per square, indicating that MW reduction of GO is promising for the convenient low-temperature preparation of transparent conductors on flexible polymeric substrates.
RESUMEN
Thermally conductive functionalized multilayer graphene sheets (fMGs) are efficiently aligned in large-scale by a vacuum filtration method at room temperature, as evidenced by SEM images and polarized Raman spectroscopy. A remarkably strong anisotropy in properties of aligned fMGs is observed. High electrical (â¼386 S cm(-1)) and thermal conductivity (â¼112 W m(-1) K(-1) at 25 °C) and ultralow coefficient of thermal expansion (â¼-0.71 ppm K(-1)) in the in-plane direction of A-fMGs are obtained without any reduction process. Aligned fMGs are vertically assembled between contacted silicon/silicon surfaces with pure indium as a metallic medium. Thus-constructed three-dimensional vertically aligned fMG thermal interfacial material (VA-fMG TIM) architecture has significantly higher equivalent thermal conductivity (75.5 W m(-1) K(-1)) and lower contact thermal resistance (5.1 mm2 K W(-1)), compared with their counterpart from A-fMGs that are recumbent between silicon surfaces. This finding provides a throughout approach for a graphene-based TIM assembly as well as knowledge of vertically aligned graphene architectures, which may not only facilitate graphene's application in current demanding thermal management but also promote its widespread applications in electrodes of energy storage devices, conductive polymeric composites, etc.