Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
BMC Musculoskelet Disord ; 23(1): 1096, 2022 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-36517815

RESUMEN

BACKGROUND: Previous studies have compared different kinds of fixations for anterior cruciate ligament reconstruction. Nevertheless, there is no optimal method to date. To the best of authors' knowledge, there is no article discussing the combination of adjustable suspensory device and interference screw for hybrid tibial fixation. METHODS: In total, 66 patients (n = 34, adjustable suspensory device and interference screw; n = 32, cortical screw and interference screw) were analyzed. Their International Knee Documentation Committee score and Tegner activity level scale were evaluated before and after a 2-year follow-up. The Single Assessment Numeric Evaluation score was evaluated after a 2-year follow-up. Physical exams such as range of motion, anterior knee pain (VAS > = 3) and Lachman test were assessed before and at least 12 months after surgery. To evaluate tunnel widening, anteroposterior and lateral view radiography was conducted 1 day and at least 12 months after surgery. A more than 10% change was considered tibial tunnel widening. Mann-Whitney U test, independent t test, paired t test, Fisher's exact test and chi-squared test were used to compare the variables. Linear and logistic regression models were applied to adjust for potential confounders. RESULTS: No variable except gender (P = 0.006) showed significant difference with regard to demographic data. After adjustment, there was no statistically significant difference between the groups regarding post-operative physical exams. Patients who used adjustable suspensory device and interference screw had lower post-operative Single Assessment Numeric Evaluation score (adjusted ß - 8.194; P = 0.017), Tegner activity level scale (adjusted ß - 1.295; P = 0.001) and pre-operative degrees of knee flexion (adjusted ß - 2.825; P = 0.026). Less percentage of tunnel widening in the lateral view of radiographs was seen in patients in group of adjustable suspensory device and interference screw (adjusted ß - 1.733; P = 0.038). No significant difference was observed in the anteroposterior view of radiographs (adjusted ß - 0.667; P = 0.26). CONCLUSION: In these 66 patients, we observed less tibial tunnel widening and lower post-operative functional scores in the group of adjustable suspensory device and interference screw. Both groups displayed similar outcomes of physical exams as well as improvement after operation. The proposed method may become an alternative option. Nonetheless, the quality of our study is still limited, and thus further studies are warranted to determine the efficacy and further application. TRIAL REGISTRATION: Joint Institutional Review Board of Taipei Medical University, Taipei, Taiwan (No: N201805094 ). STUDY DESIGN: Prospective comparative cohort study; Level of evidence, II.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior , Humanos , Estudios Prospectivos , Estudios de Cohortes , Fémur/cirugía , Reconstrucción del Ligamento Cruzado Anterior/métodos , Tibia/diagnóstico por imagen , Tibia/cirugía , Articulación de la Rodilla/cirugía , Lesiones del Ligamento Cruzado Anterior/diagnóstico por imagen , Lesiones del Ligamento Cruzado Anterior/cirugía
2.
Int J Mol Sci ; 23(23)2022 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-36498952

RESUMEN

This study evaluated the mid-term (12-month) biomechanical, biocompatibility, and biological performance of additive-manufactured bioabsorbable iron-based interference screws (ISs). Two bioabsorbable iron IS types-manufactured using pure iron powder (iron_IS) and using pure iron powder with 0.2 wt% tricalcium phosphate (TCP_IS)-were compared with conventional metallic IS (control) using in vitro biocompatibility and degradation analyses and an in vivo animal study. The in vitro ultimate failure strength was significantly higher for iron_IS and TCP_IS than for control ISs at 3 months post-operatively; however, the difference between groups were nonsignificant thereafter. Moreover, at 3 months after implantation, iron_IS and TCP_IS increased bone volume fraction, bone surface area fraction, and percent intersection surface; the changes thereafter were nonsignificant. Iron_IS and TCP_IS demonstrated degradation over time with increased implant surface, decreased implant volume, and structure thickness; nevertheless, the analyses of visceral organs and biochemistry demonstrated normal results, except for time-dependent iron deposition in the spleen. Therefore, compared with conventional ISs, bioabsorbable iron-based ISs exhibit higher initial mechanical strength. Although iron-based ISs demonstrate high biocompatibility 12 months after implantation, their corrosive iron products may accumulate in the spleen. Because they demonstrate mechanical superiority along with considerable absorption capability after implantation, iron-based ISs may have potential applications in implantable medical-device development in the future.


Asunto(s)
Fosfatos de Calcio , Hierro , Animales , Conejos , Hierro/química , Porosidad , Implantes Absorbibles
3.
Medicina (Kaunas) ; 58(9)2022 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-36143825

RESUMEN

Background and objectives: Treatment of a displaced or comminuted periprosthetic distal femur fracture is challenging, especially in patients with osteoporosis. In this case report, we shared our successful surgical experience of using a long intramedullary fibula bone graft in a plate fixation surgery for a periprosthetic distal femur fracture in an extremely elderly patient with osteoporosis. Case report: A 95-year-old woman with severe osteoporosis (bone mineral density level: -3.0) presented with right knee pain and deformity after a fall, and a right periprosthetic distal femur fracture was identified. The patient underwent an open reduction and an internal plate fixation surgery with the application of a long intramedullary fibular bone graft. Due to a solid fixation, immediate weight-bearing was allowed after the surgery. She could walk independently without any valgus or varus malalignment or shortening 3 months after the surgery. A solid union was achieved 4 months postoperatively. Conclusions: We present a case wherein a long intramedullary allogenous fibula strut bone graft was used successfully to treat a right periprosthetic femur fracture in an extremely elderly patient. A long allogenous fibula bone graft can act not only as a firm structure for bridging the bone defect but also as a guide for precise component alignment. We believe this treatment option for periprosthetic fractures is beneficial for achieving biological and mechanical stability and facilitates early mobilization and weight-bearing for the patient.


Asunto(s)
Fracturas del Fémur , Osteoporosis , Fracturas Periprotésicas , Anciano , Anciano de 80 o más Años , Placas Óseas/efectos adversos , Femenino , Fracturas del Fémur/etiología , Fracturas del Fémur/cirugía , Fémur , Peroné , Fijación Interna de Fracturas/efectos adversos , Humanos , Osteoporosis/complicaciones , Fracturas Periprotésicas/complicaciones , Fracturas Periprotésicas/cirugía , Resultado del Tratamiento
4.
Int J Mol Sci ; 22(14)2021 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-34298988

RESUMEN

This study evaluated the biocompatibility and biological performance of novel additive-manufactured bioabsorbable iron-based porous suture anchors (iron_SAs). Two types of bioabsorbable iron_SAs, with double- and triple-helical structures (iron_SA_2_helix and iron_SA_3_helix, respectively), were compared with the synthetic polymer-based bioabsorbable suture anchor (polymer_SAs). An in vitro mechanical test, MTT assay, and scanning electron microscope (SEM) analysis were performed. An in vivo animal study was also performed. The three types of suture anchors were randomly implanted in the outer cortex of the lateral femoral condyle. The ultimate in vitro pullout strength of the iron_SA_3_helix group was significantly higher than the iron_SA_2_helix and polymer_SA groups. The MTT assay findings demonstrated no significant cytotoxicity, and the SEM analysis showed cells attachment on implant surface. The ultimate failure load of the iron_SA_3_helix group was significantly higher than that of the polymer_SA group. The micro-CT analysis indicated the iron_SA_3_helix group showed a higher bone volume fraction (BV/TV) after surgery. Moreover, both iron SAs underwent degradation with time. Iron_SAs with triple-helical threads and a porous structure demonstrated better mechanical strength and high biocompatibility after short-term implantation. The combined advantages of the mechanical superiority of the iron metal and the possibility of absorption after implantation make the iron_SA a suitable candidate for further development.


Asunto(s)
Implantes Absorbibles , Materiales Biocompatibles , Anclas para Sutura , Alanina Transaminasa/sangre , Animales , Materiales Biocompatibles/química , Materiales Biocompatibles/toxicidad , Fenómenos Biomecánicos , Nitrógeno de la Urea Sanguínea , Fosfatos de Calcio/química , Fosfatos de Calcio/toxicidad , Sulfato de Calcio/administración & dosificación , Sulfato de Calcio/química , Sulfato de Calcio/toxicidad , Creatinina/sangre , Diseño de Equipo , Fémur/diagnóstico por imagen , Fémur/ultraestructura , Hierro , Rayos Láser , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Estructura Molecular , Oseointegración , Polímeros/química , Polímeros/toxicidad , Porosidad , Conejos , Distribución Aleatoria , Resistencia a la Tracción , Vísceras , Microtomografía por Rayos X
5.
Eur J Public Health ; 30(1): 4-9, 2020 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-31177269

RESUMEN

BACKGROUND: There is a lack of evidence that shows whether a report card can improve health outcomes in terms of infection rates or unscheduled readmission by using rigorous methods to evaluate its impact. METHODS: We used the National Health Insurance Administration's claims database from 1 January 2004 to 30 December 2013 and a time series analysis to evaluate the impact of the quality report card initiative on three negative outcomes of total knee replacement for each quarter of the year, including the rates of superficial infection of a knee replacement, deep infection of knee arthroplasty and unplanned readmissions for surgical site infection. RESULTS: These negative outcomes (original scale) do not show significant decreases in terms of superficial infection (-0.05‰, -0.63 to 0.53‰, P = 0.87), deep infection (-0.003‰, -0.19 to 0.18‰, P = 0.97) and unscheduled readmission (0.02‰, -0.21 to 0.25‰, P = 0.88). CONCLUSION: The total knee replacement public report card initiative did not improve the rate of infection and unscheduled readmission for surgical site infection. This report card in Taiwan should involve physicians' participation in the design and be tailored to be suitable for reading by patients in order to further enhance the chance of improvement in these negative outcomes.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Humanos , Análisis de Series de Tiempo Interrumpido , Readmisión del Paciente , Estudios Retrospectivos , Factores de Riesgo , Taiwán
6.
BMC Musculoskelet Disord ; 21(1): 667, 2020 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-33032565

RESUMEN

BACKGROUND: Several cup anteversion measurements for post-operative total hip arthroplasty (THA) surgery have been described. We developed the standardized Liaw's trigonometric method to eliminate the influence of patient position, which is the most accurate method for cup anteversion measurement. We then developed an ellipse method using the Elliversion software and reported an interobserver error reduction in 2013. In this study, we attempted to apply this ellipse method in the clinic and compared its accuracy with the standard trigonometric version. METHODS: In the present study, we attempted to incorporate the ellipse method with Liaw's standardized anteversion in the simulated cup position. We measured standardized Liaw's anteversion for 434 radiographs in the clinic using the ellipse method. Repeated standard deviation (RSD) was calculated for accuracy evaluation. Furthermore, paired t-test was used for comparison with the interobserver and intraobserver errors. RESULTS: We found that the standardized Liaw's anteversion measured using the ellipse method showed lower RSD than the radiographic version. RSD was 0.795 in the standardized Liaw's anteversion with ellipse method group. The p-values of the paired t-test were all higher than 0.05 when measuring the interobserver and intraobserver errors. It indicated that the ellipse method was a precise and simple tool for cup anteversion measurement. CONCLUSION: We believe that this ellipse measurement can assist surgeons while placing the acetabulum cup into the precise position and enable early diagnosis of acetabulum loosening.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Humanos , Periodo Posoperatorio , Radiografía
7.
BMC Musculoskelet Disord ; 21(1): 92, 2020 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-32041587

RESUMEN

BACKGROUND: Compared to other types of surgeries, minimally invasive surgeries (MISs) of humeral shaft fractures are associated with less radial nerve injury, less soft tissue injury and higher union rate. However, malrotation often occurs in MISs when closed reduction methods are used. This study aims to define specific palpable landmarks to help surgeons determine the correct torsional angle and reduce the incidence of malrotation. METHODS: Twenty-eight normal humeral computed tomography scans were retrieved from our image database. One line was drawn through the vertices of the intertubercular sulcus of the humeral head in the coronal view, and another line was drawn through the longest axis between the medial and lateral condyles in the coronal view. The angle between these two lines was measured at least 3 times for each scan. RESULTS: The profile of the intertubercular sulcus tangent line of the humeral head and the axis of the distal humerus was identified as the most accurate method for assessing the precision of torsion during MIS for humeral shaft fractures. The transepicondylar axis line is more internally rotated than the intertubercular sulcus tangent line. The mean angle was measured to be 41.1 degrees. CONCLUSIONS: The axis of the distal humeral condyles is internally rotated by approximately 41.1 degrees compared with the intertubercular sulcus tangent line of the humeral head. Minimally invasive surgeries can be performed by using these palpable landmarks. The torsional deformities can be reduced with the proper angle adjustment without the need for fluoroscopy. It can also be used to treat unstable comminuted humeral fractures. LEVEL OF EVIDENCE: Retrospective Study, Diagnostic study, Level III.


Asunto(s)
Puntos Anatómicos de Referencia , Fracturas del Húmero/cirugía , Húmero/diagnóstico por imagen , Anomalía Torsional/prevención & control , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Fijación de Fractura/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Anomalía Torsional/etiología , Adulto Joven
8.
J Foot Ankle Surg ; 55(1): 106-11, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26364234

RESUMEN

Measuring bone angles is an important method for diagnosing disease and predicting the prognosis in orthopedics. Traditionally, the angle is measured using lines drawn manually and adjusted by the naked eye. The purpose of the present study was to propose new methods to measure the bone angles formed by the axes of the calcaneus with good reliability and low operational error. The 2 new methods used linear regression analysis of the points inside and on the "envelope" line. The traditional method used the vector of the lines drawn for calculation. Digital radiographs of the lateral view of the feet from 51 patients were collected, and the angles were measured using these 3 methods. Next, we analyzed the reliability, differences, and correlations of these 3 methods. The intra- and interobserver comparisons revealed significant differences between the results of the 2 new methods and those of the traditional method. In addition, the new methods had greater reliability and better intra- and interobserver correlations than did the traditional method. We suggest that these 2 new methods to measure bone axis should be added to the Picture Archiving and Communication System to obtain more reliable and standardized data in clinical practice and for future research purposes.


Asunto(s)
Calcáneo/diagnóstico por imagen , Ortopedia/métodos , Intensificación de Imagen Radiográfica/métodos , Humanos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados
9.
Aging Ment Health ; 19(6): 548-59, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25266062

RESUMEN

OBJECTIVES: Little is known about the influence of routine laboratory measurements and lifestyle factors on generic quality of life (QOL) at older ages. We aimed to study the relationship between generic QOL and laboratory measurements and lifestyle factors in community dwelling older Chinese people. METHODS: We conducted a cross-sectional analysis. Six hundred and ninety nine elders were randomly selected from the examinees of the annual health examination in Taipei City, Taiwan. Blood, urine and stool of the participants were examined and lifestyle data were collected. Participants completed the CASP-19 (control, autonomy, self-realization, pleasure) questionnaire, a 19-item QOL scale. The relationship between QOL and laboratory results and lifestyle factors was explored, using multiple linear regression and profile analysis. RESULTS: The mean age of the participants was 75.5 years (SD = 6.5), and 49.5% were female. Male gender standardized ß coefficients (ß = 0.122) and exercise habit (ß = 0.170) were associated with a better QOL, whereas advanced age (ß = -0.242), blurred vision (ß = -0.143), depression (ß = -0.125), central obesity (ß = -0.093), anemia (ß = -0.095), rheumatoid arthritis (ß = -0.073), Parkinsonism (ß = -0.079), malignancy (ß = -0.086) and motorcycle riding (ß = -0.086) were associated with a lower QOL. Profile analysis revealed that young-old males, social drinkers, regular exercisers and car drivers had the best QOL (all p < 0.001). CONCLUSION: Of the many laboratory measurements, only anemia was associated with the lower QOL. By contrast, several lifestyle factors, such as social drinking, exercise habit and car driving, were associated with better QOL, whereas abdominal obesity and motorcycle riding were associated with lower QOL.


Asunto(s)
Envejecimiento/fisiología , Envejecimiento/psicología , Evaluación Geriátrica/métodos , Vida Independiente/psicología , Estilo de Vida/etnología , Calidad de Vida/psicología , Anciano , Anciano de 80 o más Años , Envejecimiento/etnología , Índice de Masa Corporal , Estudios Transversales , Análisis Factorial , Femenino , Indicadores de Salud , Humanos , Vida Independiente/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Factores Socioeconómicos , Encuestas y Cuestionarios , Taiwán/epidemiología
10.
Eur Spine J ; 23(5): 999-1006, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24395004

RESUMEN

STUDY DESIGN: This is a retrospective study. PURPOSE: To compare the morphometric parameters of the psoas major and lumbar multifidus muscles in lumbar spinal stenosis (LSS) patients exhibiting different functional performance. LSS refers to symptoms related to size reduction of the lumbar spinal canal; however, the degree of stenosis is poorly related to symptom severity and functional impairments. Morphometric changes in the paraspinal muscles have been correlated with chronic lower back pain in previous studies. However, correlations between the functional performance of LSS patients and the morphometric changes in paraspinal muscles have seldom been reported. METHODS: Sixty-six LSS patients without mechanical back pain or segmental instability were enrolled in the study. A review of their medical records and MRI images was performed. Morphometric parameters, including the fatty infiltration (FI) of the lumbar multifidus muscle as well as the relative cross-sectional area (RCSA) of the psoas major and lumbar multifidus muscles, were measured. Subjects were divided into high and low functional performance groups according to their Japanese Orthopedic Association (JOA) scores. RESULTS: The male LSS patients exhibited a larger psoas RCSA than the female patients, whereas the older patients exhibited a smaller psoas RCSA and higher multifidus FI than the younger patients. LSS patients in the high functional performance group exhibited a significantly larger psoas RCSA and lower multifidus FI. CONCLUSION: The psoas RCSA and multifidus FI can be used as predictive factors for functional performance in LSS patients.


Asunto(s)
Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/fisiopatología , Músculos Paraespinales/diagnóstico por imagen , Estenosis Espinal/diagnóstico por imagen , Estenosis Espinal/fisiopatología , Factores de Edad , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Dolor de la Región Lumbar/etiología , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Radiografía , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Factores Sexuales
11.
Orthop Surg ; 16(1): 276-281, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37986662

RESUMEN

Improper acetabulum component position is a significant risk factor for postoperative dislocation after total hip arthroplasty. Several radiographic two-dimensional methods exist for measuring acetabulum component anteversion, but they cannot distinguish between anteversion and retroversion. "Liaw's version," initially proposed as a simple mathematical standardized two-dimensional method, was modified to the computerized ellipse method, proving superior accuracy to traditional two-dimensional methods. In this article, we demonstrated its application in detecting and measuring retroverted acetabulum component. We obtained anteroposterior pelvis radiographs from a patient undergoing total hip arthroplasty on the day of surgery and 2 weeks postoperatively. The computerized ellipse method was used to measure the acetabulum component orientation. Upon comparison, the difference between θ assigned to be retroverted (9.52-8.56 = 0.96) is much smaller than the difference between θ assigned to be anteverted (23.81-18.86 = 4.95), leading us to determine retroversion. This was further confirmed by computed tomography at the 6-week follow-up. We propose that using the computerized ellipse method to measure Liaw's version can be a valuable tool in identifying acetabulum component retroversion on anteroposterior radiographs during routine postoperative follow-up and retrospective assessments of total hip arthroplasty patients.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Estudios Retrospectivos , Radiografía , Artroplastia de Reemplazo de Cadera/métodos
12.
Bone Rep ; 20: 101742, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38404728

RESUMEN

Introduction: Fractures affect people's quality of life especially in the elders. One of the most important risk factors is osteoporosis. There are many screening tools to predict osteoporosis and fractures. We aimed to compare the predictive validity of three commonly used screening tools: fracture risk assessment tool (FRAX), osteoporosis self-assessment tool for Asians (OSTA) and one-minute osteoporosis risk test. Among them, OSTA and one-minute osteoporosis risk test were originally developed to predict osteoporosis risks and FRAX was to predict fracture risks. Methods: This is an 11-year longitudinal study. We enrolled 708 senior people from health examinees in Taiwan in 2010. A standardized questionnaire and blood tests were provided. Annual telephone interview was conducted to assess the real fracture status. We calculated risk scores of FRAX, OSTA, and one-minute osteoporosis risk test and compared with real-world fracture records. Results: The mean age of the participants were 74.9 (SD 6.4). There were 356 (50.3 %) men. From 2010 to 2020, a total of 105 (14.8 %) persons suffered from fractures. Compared to people without fractures, people with fractures had higher FRAX major osteoporotic fracture risk scores (14.0 % ± 7.6 % vs.11.3 % ± 5.7 %), higher hip fracture risk scores, and higher OSTA risk (5.9 % ± 1.4 % vs. 5.3 % ± 1.3 %). Cox regression analysis showed that hazard ratios for fracture of high FRAX risk was 1.53 (95 % confidence interval (CI) 1.05-2.21), and for high OSTA risk was 1.37 (95 % CI 1.04-1.82). Conclusions: Only OSTA and FRAX scores were satisfactory in predicting 10-year fractures.

13.
Prev Med ; 57(5): 511-7, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23872174

RESUMEN

OBJECTIVE: The purpose of this study is to contribute evidence towards heterogeneity in risk factors for single and recurrent falls. METHOD: This is a prospective study conducted in Taiwan. Participants were randomly selected from the examinees of the annual health examination in 2010. Participants were interviewed with a detailed questionnaire and followed up one year later. Predictor variables included socio-demographic characteristics, medical conditions, laboratory data, and risk factors for osteoporosis. The outcome was falls in the ensuing 12 months. RESULTS: The mean age of the 653 completers was 75.6 ± 6.4. Half (48.7%) were women. Fallers and recurrent fallers comprised 14.5% and 6.0% of the participants, respectively. Blurred vision (adjusted odds ratio (aOR): 1.93, 95% confidence interval (CI): 1.02-3.67), minimal outdoor activities (aOR: 2.28, 95% CI: 1.06-4.88), and overactive thyroid/parathyroid (aOR: 3.49, 95% CI: 1.29-9.50) were associated with single falls. Frailty (aOR: 2.81, 95% CI: 1.11-7.09), decreased body height (aOR: 3.15, 95% CI: 1.52-6.54) and taking sedatives/hypnotics (aOR: 4.23, 95% CI: 2.06-8.67) were associated with recurrent falls. Previous falls (aOR: 2.64, 95% CI: 1.44-4.84 for single falls; aOR: 5.26, 95% CI: 2.61-10.60 for recurrent falls) were associated with all falls. CONCLUSION: Different intervention strategies should be developed for single and recurrent fallers.


Asunto(s)
Accidentes por Caídas/estadística & datos numéricos , Vida Independiente/estadística & datos numéricos , Accidentes por Caídas/prevención & control , Anciano , Anciano de 80 o más Años , Disfunción Cognitiva/epidemiología , Estudios Transversales , Femenino , Estudios de Seguimiento , Anciano Frágil/estadística & datos numéricos , Evaluación Geriátrica/estadística & datos numéricos , Humanos , Masculino , Estudios Prospectivos , Factores de Riesgo , Prevención Secundaria , Taiwán
14.
J Arthroplasty ; 28(10): 1788-90, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23850409

RESUMEN

Evaluating three-dimensional angle error is necessary because we cannot get every patient's CT or MRI at all times. Creating a method that can calculate angle error from plain radiographs is therefore important. Using vector and trigonometric mathematics, we gradually deduct our formula which can calculate angle error from goal angles (the angles we plan to achieve before operation) to result angles (the angles we get after operation) by two perpendicular radiographs. We also encode it into Micorsoft Excel (Redmond Campus, Redmond, Washington, U.S.) so that it becomes more user-friendly. We hope this tool can be used when evaluating TKR, corrective osteotomy, fracture fixation, and so on.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/diagnóstico por imagen , Tibia/diagnóstico por imagen , Humanos , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Modelos Biológicos , Radiografía , Tibia/cirugía
15.
Biomedicines ; 11(5)2023 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-37239066

RESUMEN

Currently, orthopedic surgeons mainly use the inter-teardrop line (IT-line) as the transverse mechanical axis of the pelvis (TAP) for postoperative evaluation of total hip arthroplasty (THA). However, the teardrop is often unclear in the pelvis anteroposterior (AP) radiographs, which makes postoperative evaluation of THA difficult. In this study, we attempted to identify other clear and accurate axes for postoperative evaluation of THA. We calculated the mean and standard deviation of these angles and tested the significance of these angles using t-tests. The inter-teardrops line (IT line) and the upper rim of the obturator foramen (UOF) had smaller angles with the IFH line. The bi-ischial line (BI line) was relatively inaccurate in measurements. We recommend using the IT line as the TAP when the lower boundary of the teardrops is clear and the shapes of the teardrops on both sides of the pelvis are symmetrical. When there is no deformation of the obturator foramen on pelvic AP radiographs, the UOF is also a good choice for the TAP. We do not recommend the BI line as the TAP.

16.
Orthop J Sports Med ; 11(1): 23259671221142242, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36636031

RESUMEN

Background: Single-row (SR) and double-row repair techniques have been described to treat rotator cuff tears. We present a novel surgical strategy of arthroscopic-assisted mini-open repair in which a locking-loop suture bridge (LLSB) is used. Purpose: To compare the functional outcomes and repair integrity of LLSB technique to the SR technique for arthroscopic-assisted mini-open repair of small to medium rotator cuff tears. Study Design: Cohort study; Level of evidence, 3. Methods: Included were 39 patients who underwent LLSB repair (LLSB group) and 44 patients who underwent SR suture anchor repair (SR group) from 2015 to 2018. We evaluated all patients preoperatively and at 3, 6, 12, and 24 months postoperatively using the visual analog scale (VAS) for pain, Oxford Shoulder Score (OSS), and American Shoulder and Elbow Surgeons (ASES) score. Also, shoulder sonography was performed at 12 months postoperatively to evaluate repair integrity using the Sugaya classification system. The independent-sample t test was used to analyze functional outcomes (VAS, OSS, and ASES scores), and the Fisher exact test was used to analyze postoperative sonography results. Results: Patients in both the LLSB and SR groups saw a significant improvement on all 3 outcome measures from preoperatively to 24 months postoperatively (P < .001 for all). However, when comparing scores between groups, only the scores at 3 months postoperatively differed significantly (VAS: P = .002; OSS: P < .001; ASES: P = .005). Shoulder sonography at 12 months postoperatively revealed no significant difference in repair integrity between the LLSB and SR groups (retear rate: 10.26% and 6.82%, respectively; P = .892). Conclusion: Better outcome scores were seen at 3-month follow-up in the LLSB group, with no difference in retear rates compared with the SR group at 12 months postoperatively. The LLSB technique was found to be a reliable technique for rotator cuff repair of small- to medium-sized tears.

17.
Carbohydr Polym ; 322: 121338, 2023 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-37839831

RESUMEN

Machine learning (ML) has been used for many clinical decision-making processes and diagnostic procedures in bioinformatics applications. We examined eight algorithms, including linear discriminant analysis (LDA), logistic regression (LR), k-nearest neighbor (KNN), random forest (RF), gradient boosting machine (GBM), support vector machine (SVM), Naïve Bayes classifier (NB), and artificial neural network (ANN) models, to evaluate their classification and prediction capabilities for four tissue types in Wolfiporia extensa using their monosaccharide composition profiles. All 8 ML-based models were assessed as exemplary models with AUC exceeding 0.8. Five models, namely LDA, KNN, RF, GBM, and ANN, performed excellently in the four-tissue-type classification (AUC > 0.9). Additionally, all eight models were evaluated as good predictive models with AUC value > 0.8 in the three-tissue-type classification. Notably, all 8 ML-based methods outperformed the single linear discriminant analysis (LDA) plotting method. For large sample sizes, the ML-based methods perform better than traditional regression techniques and could potentially increase the accuracy in identifying tissue samples of W. extensa.


Asunto(s)
Wolfiporia , Teorema de Bayes , Aprendizaje Automático , Algoritmos , Redes Neurales de la Computación
18.
J Clin Med ; 11(21)2022 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-36362581

RESUMEN

There are many published cup anteversion measurements for postoperative total hip arthroplasty (THA), including Liaw's, Lewinnek's, and Murray's methods. However, most measurements ignore the potential pelvic rotation on radiographs except in Liaw's method. Without considering pelvic rotation, clinicians can miscalculate cup anteversion. Therefore, we aimed to quantify the mean degree of pelvic rotation. Herein, we collected 388 radiographs of 98 postoperative THA hips of 77 patients and measured pelvic rotation by measuring h, the horizontal displacement of the sacrococcygeal junction associated with the upper pole of the symphysis pubis, and ssd, the distance between the sacrococcygeal junction and pubic symphysis. The angle θ of pelvic rotation was defined as θ = arc sin (h/ssd) × (180°/π). The mean degree of pelvic rotation was then calculated. The standard deviation of h was 7.84 mm, and the mean ssd was 158 mm. The potential pelvic rotation was 2.50°. The p-values from the paired t-test were all >0.05 when interobserver and intraobserver errors were assessed. This is the first study to quantify the potential pelvic rotation in the coronal plane on postoperative plain radiographs. The potential pelvic rotation was too large to be neglected during the measurement of cup anteversion.

19.
Front Surg ; 9: 1033453, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36353614

RESUMEN

Introduction: For patients undergoing THR, measuring the postoperative acetabular anteversion precisely plays a pivotal role in the prognosis. However, using elliptical methods mandates computerized equipment that is frequently in shortage in remote areas and developing countries. We invented a laser projector utilizing the ellipse method to measure the acetabular anteversion directly. The aim is to examine the consistency and validity of the laser projector as compared to our original software, Elliversion. Materials and Methods: We retrospectively collected 50 postoperative pelvis radiographs including acetabulum from our institution. One investigator first measured the anteversion of included radiographs through Elliversion software as the control group. Subsequently, two operators independently used the laser projector for measurements in two separate periods with 1-day intervals as the experimental group. Our analysis was comprised of intra- and inter-observer comparisons and reliability, which investigated both the consistency and validity, by using two-sample student's t-test and intraclass correlation coefficient. Results: There was no significant difference in measuring the anteversion through laser projectors between two operators (p = 0.54), with excellent inter-observer reliability (ICC, 0.967). The estimated effect in the anteversion measurement between the Elliversion and laser projector was also comparable, with the ICC level of 0.984, indicating excellent reliability. Conclusion: Our study reported the consistency and validity of this laser projector as there is no significant difference between Elliversion and Laser projector, notably with excellent intra- and inter-observer reliability. We look forward to helping elevate clinical acumen when doctors provide care to patients after THR, especially in remote areas.

20.
Front Surg ; 9: 1000404, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36311919

RESUMEN

Distal radius orientation is important in evaluating Colles' fracture. In most cases, the wrist was protected by a bandage, splint, or cast. Therefore, it was difficult for the radiology technician to take perfect anteroposterior and lateral view radiographs. In this study, we build a mathematical model and calculate the pronation angle needed to produce dorsal tilt, which is a volar tilt in a perfect lateral view radiograph. The formulas are all incorporated into Excel to facilitate usage.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA