Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Acta Radiol ; 62(5): 594-602, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-32551805

RESUMEN

BACKGROUND: The coronary venous system is frequently used as an entry route to the heart and treatment modalities for many cardiac diseases and many procedures. Consequently, evaluation of the coronary venous system and understanding cardiac vein anatomy is crucial. PURPOSE: To determine the optimal image set in a comparison of noise-optimized linearly blended images (F_0.6) and noise-optimized virtual monoenergetic images (VMI+) evaluated by dual-energy computed tomography (DECT) for cardiac vein assessment. MATERIAL AND METHODS: Thirty-four patients (mean age 58.2 ± 14.2 years) who underwent DECT due to chest pain were enrolled. Images were post-processed with the F_0.6, and VMI+ algorithms at energy levels in the range of 40-100 keV in 10-keV increments. Enhancement (HU), noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were objectively measured at two points in the great cardiac vein by consensus of two radiologists. Two blinded observers evaluated the subjective image quality of the great cardiac vein on a 4-point scale. RESULTS: HU, noise, and SNR peaked at 40 keV VMI+ (P < 0.05) among 50-100 keV VMI+. CNR peaked at 100 keV VMI+; however, there were no significant differences compared to CNR images processed at 40-90 keV VMI+. HU and noise were significantly higher in 40 keV VMI+ than F_0.6 images; however, both SNR and CNR were significantly higher in F_0.6 images. An assessment of subjective vein delineation revealed that F_0.6 images had the highest scores. CONCLUSION: F_0.6 images were superior to VMI+ and provided the optimal image set for cardiac vein assessment.


Asunto(s)
Vasos Coronarios/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Imagen Radiográfica por Emisión de Doble Fotón , Estudios Retrospectivos , Relación Señal-Ruido , Adulto Joven
2.
Acta Radiol ; 59(5): 546-552, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-28766981

RESUMEN

Background Computed tomography venography (CTV) at low kVp using model-based iterative reconstruction (MBIR) can enhance vascular enhancement with noise reduction. Purpose To evaluate image qualities and radiation doses of CTV at 80 kVp using MBIR and a small iodine contrast media (CM) dose and to compare these with those of CTV performed using a conventional protocol. Material and Methods Sixty-five patients (mean age = 58.1 ± 7.2 years) that underwent CTV for the evaluation of deep vein thrombosis (DVT) and varicose veins were enrolled in this study. Patients were divided into two groups: Group A (35 patients, 80 kVp, MBIR, automatic tube current modulation, CM = 270 mg/mL, 100 mL) and Group B (30 patients, 100 kVp, filtered back projection [FBP], 120 fixed mA, CM = 370 mg/mL, 120 mL). Objective and subjective image qualities of inferior vena cava (IVC), femoral vein (FV), and popliteal vein (PV) were assessed and radiation doses were recorded. Results Mean vascular enhancement in group A was significantly lower than in group B ( P < 0.01). Noise in group A was significantly lower than in group B except for PV and contrast-to-noise ratio were not significantly different in the two groups ( P > 0.05). In addition, radiation dose in group A was significantly lower than in group B ( P < 0.001). Subjective image quality comparison revealed group A was statistically inferior to group B except for subjective image noise. Conclusion CTV at 80 kVp using MBIR with small iodine contrast dose provided acceptable image quality at a lower radiation dose than conventional CTV using FBP.


Asunto(s)
Flebografía/métodos , Tomografía Computarizada por Rayos X/métodos , Várices/diagnóstico por imagen , Trombosis de la Vena/diagnóstico por imagen , Medios de Contraste/administración & dosificación , Femenino , Vena Femoral/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Vena Poplítea/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Estudios Retrospectivos , Vena Cava Inferior/diagnóstico por imagen
3.
Eur Radiol ; 26(7): 2055-63, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26486938

RESUMEN

PURPOSE: To evaluate the subjective and objective qualities of computed tomography (CT) venography images at 80 kVp using model-based iterative reconstruction (MBIR) and to compare these with those of filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR) using the same CT data sets. MATERIALS AND METHODS: Forty-four patients (mean age: 56.1 ± 18.1) who underwent 80 kVp CT venography (CTV) for the evaluation of deep vein thrombosis (DVT) during 4 months were enrolled in this retrospective study. The same raw data were reconstructed using FBP, ASIR, and MBIR. Objective and subjective image analysis were performed at the inferior vena cava (IVC), femoral vein, and popliteal vein. RESULTS: The mean CNR of MBIR was significantly greater than those of FBP and ASIR and images reconstructed using MBIR had significantly lower objective image noise (p < .001). Subjective image quality and confidence of detecting DVT by MBIR group were significantly greater than those of FBP and ASIR (p < .005), and MBIR had the lowest score for subjective image noise (p < .001). CONCLUSION: CTV at 80 kVp with MBIR was superior to FBP and ASIR regarding subjective and objective image qualities. KEY POINTS: • MBIR provides superior image quality compared with FBP and ASIR • CTV at 80kVp with MBIR improves diagnostic confidence in diagnosing DVT • CTV at 80kVp with MBIR presents better image quality with low radiation.


Asunto(s)
Flebografía/métodos , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Trombosis de la Vena/diagnóstico por imagen , Adulto , Anciano , Algoritmos , Femenino , Vena Femoral/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Vena Poplítea/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/normas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/normas , Vena Cava Inferior/diagnóstico por imagen
4.
Int J Clin Oncol ; 21(5): 875-882, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27230992

RESUMEN

BACKGROUND: Various subtypes of melanoma-associated antigens (MAGEs) are expressed in the tumor tissues of patients with head and neck squamous cell carcinoma (HNSCC). However, little data are currently available on how the gene expression of MAGEs impacts clinical patterns and oncologic outcomes. We have therefore evaluated the expression of MAGE-A1-6 (A1-6) subtypes in tumor tissues of patients with HNSCC and the clinical impact of this expression. METHODS: This was a retrospective review of 53 patients with histologically proven HNSCC of the oral cavity, oropharynx, larynx, or hypopharynx who underwent both treatment and analysis by reverse transcription (RT)-PCR assay with a common primer to identify the expression of MAGE-A1-6 subtypes in the tumor tissue. The clinicopathologic factors and oncologic outcomes of these patients and the correlations of both to MAGE-A1-6 gene expression were analyzed. RESULTS: MAGE-A1-6 subtypes were expressed in the tumor tissues of 37 patients (69.8 %). Patient age of ≥65 years [p = 0.031, hazard ratio (HR) 4.866] and advanced American Joint Committee on Cancer stage (p = 0.035, HR 4.291) were independent risk factors for expression of MAGE-A1-6 subtypes. Patients with MAGE-A1-6 expression had lower disease-free survival (p = 0.029), disease-specific survival (p = 0.070), and overall survival (p = 0.017) rates. Overall survival rate was independently associated to chemotherapy (p = 0.011, HR 2.859), while no surgery (p = 0.050, HR 2.400) and MAGE-A1-6 expression (p = 0.050, HR 2.527) showed borderline significance. CONCLUSION: In our patient group the expression of MAGE-A1-6 subtypes in tumor tissues of patients with HNSCC was correlated with advanced clinical stage of cancer and poor oncologic outcomes. We suggest that gene expression of MAGE-A1-6 subtypes may be considered to be a predictive factor to determine patient treatment or follow-up strategy.


Asunto(s)
Carcinoma de Células Escamosas/genética , Antígenos Específicos del Melanoma/genética , Neoplasias de la Boca/genética , Neoplasias de Oído, Nariz y Garganta/genética , Factores de Edad , Anciano , Anciano de 80 o más Años , Antígenos de Neoplasias/biosíntesis , Carcinoma de Células Escamosas/terapia , Supervivencia sin Enfermedad , Femenino , Expresión Génica , Humanos , Masculino , Persona de Mediana Edad , Neoplasias de la Boca/terapia , Proteínas de Neoplasias , Neoplasias de Oído, Nariz y Garganta/terapia , Estudios Retrospectivos , Tasa de Supervivencia
5.
Acta Radiol ; 57(7): 822-8, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26419254

RESUMEN

BACKGROUND: Multi-detector computed tomography (MDCT) angiography is now used for the diagnosing patients with peripheral arterial disease. The dose of radiation is related to variable factors, such as tube current, tube voltage, and helical pitch. PURPOSE: To assess the diagnostic performance and radiation dose of lower extremity CT angiography (CTA) using a 128-slice dual source CT at 80 kVp and high pitch in patients with critical limb ischemia (CLI). MATERIAL AND METHODS: Twenty-eight patients (mean, 64.1 years; range, 39-80 years) with CLI were enrolled in this retrospective study and underwent CTA using a 128-slice dual source CT at 80 kVp and high pitch and subsequent intra-arterial digital subtraction angiography (DSA), which was used as a reference standard for assessing diagnostic performance. RESULTS: For arterial segments with significant disease (>50% stenosis), overall sensitivity, specificity, and accuracy of lower extremity CTA were 94.8% (95% CI, 91.7-98.0%), 91.5% (95% CI, 87.7-95.2%), and 93.1% (95% CI, 90.6-95.6%), respectively, and its positive and negative predictive values were 91.0% (95% CI, 87.1-95.0%), and 95.1% (95% CI, 92.1-98.1%), respectively. Mean radiation dose delivered to lower extremities was 266.6 mGy.cm. CONCLUSION: Lower extremity CTA using a 128-slice dual source CT at 80 kVp and high pitch was found to have good diagnostic performance for the assessment of patients with CLI using an extremely low radiation dose.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Isquemia/diagnóstico por imagen , Extremidad Inferior/irrigación sanguínea , Extremidad Inferior/diagnóstico por imagen , Enfermedades Vasculares Periféricas/diagnóstico por imagen , Dosis de Radiación , Adulto , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Sensibilidad y Especificidad
6.
Eur Arch Otorhinolaryngol ; 273(10): 3277-85, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26758291

RESUMEN

The importance of pathologic features of metastatic lymph nodes (LNs), such as size, number, and extranodal extension, has been recently emphasized in patients with papillary thyroid carcinoma (PTC). We evaluated the characteristics of metastatic LNs identified after prophylactic central neck dissection (CND) in patients with PTC. We performed a retrospective review of 1,046 patients who underwent unilateral or bilateral thyroidectomy with ipsilateral prophylactic CND. We reviewed the characteristics of the metastatic LNs and analyzed their correlation to the clinicopathologic characteristics of the primary tumor. Cervical LN metastasis after prophylactic CND was identified in 280 out of 1046 patients (26.8 %). The size of metastatic foci (≥2 mm) was independently correlated with primary tumor size (≥1 cm) (p = 0.016, OR = 1.88). Primary tumor size (≥1 cm) was also correlated to the number of metastatic LNs (≥5) (p = 0.004, OR = 3.14) and extranodal extension (p = 0.021, OR = 2.41) in univariate analysis. The size of the primary tumor affects pathologic features of subclinical LN metastasis in patients with PTC. Patients with primary tumors ≥1 cm have an increased risk of larger LN metastases (≥2 mm), an increased number of LN metastases (≥5), and a higher incidence of ENE, which should be considered in decision for prophylactic CND.


Asunto(s)
Carcinoma , Ganglios Linfáticos , Disección del Cuello/métodos , Neoplasias de la Tiroides , Tiroidectomía/métodos , Adulto , Carcinoma/patología , Carcinoma/cirugía , Carcinoma Papilar , Femenino , Humanos , Ganglios Linfáticos/patología , Ganglios Linfáticos/cirugía , Metástasis Linfática , Masculino , Persona de Mediana Edad , República de Corea , Estudios Retrospectivos , Factores de Riesgo , Estadística como Asunto , Cáncer Papilar Tiroideo , Neoplasias de la Tiroides/patología , Neoplasias de la Tiroides/cirugía , Carga Tumoral
7.
Acta Radiol ; 54(4): 389-95, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23550182

RESUMEN

BACKGROUND: Coronary CT angiography (CCTA) allows accurate evaluation of coronary artery stenosis but has limitations in information on hemodynamic significance of stenotic lesions. PURPOSE: To determine the feasibility of adenosine-stress low-dose single-scan CT myocardial perfusion imaging (MPI) using a 128-slice dual-source CT scanner for the diagnosis of hemodynamically significant coronary artery stenosis as defined by fractional flow reserve (FFR). MATERIAL AND METHODS: This study was proved by the Institutional Review Board and informed consent was obtained from the patients before enrollment in the study. Ninety-seven patients with chest pain and low-to-intermediate pretest probability of coronary artery disease were prospectively enrolled. Adenosine-stress CCTA using ECG-correlated maximum tube current modulation (Mindose(®)) with 128-slice dual-source CT was performed in all 97 patients. In 37 patients (38.1%; 28 men, nine women; mean age, 61.7 ± 20.5 years; mean heart rate, 74.6 ± 2.8 bpm) with significant stenosis at CCTA (lumen diameter reduction >50%), FFR was performed after CCTA, as a reference standard for the evaluation of myocardial perfusion. FFR value ≤0.75 was considered as positive. CTMPI and CCTA were read by two experienced radiologists with consensus, respectively. RESULTS: The effective radiation dose of adenosine-stress single-scan CTMPI was 4.63 ± 2.57 mSv. Compared with FFR, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for identifying significant coronary stenoses were 93.1%, 82.7%, 75.0%, and 95.6%, respectively, on CCTA and 93.1%, 90.3%, 84.4%, and 95.9%, respectively, on CTMPI. On combined CCTA and CTMPI, sensitivity, specificity, PPV, and NPV were 93.1%, 94.2%, 90.0%, and 96.0%, respectively. CONCLUSION: Adenosine-stress low-dose single scan CTMPI using a 128-slice dual-source CT can provide complementary information on the hemodynamical significance of coronary artery stenosis as well as anatomical information of coronary arteries.


Asunto(s)
Adenosina , Estenosis Coronaria/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Imagen de Perfusión Miocárdica/métodos , Tomografía Computarizada por Rayos X/métodos , Vasodilatadores , Técnicas de Imagen Sincronizada Cardíacas , Medios de Contraste , Angiografía Coronaria , Estudios de Factibilidad , Femenino , Humanos , Yohexol/análogos & derivados , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Sensibilidad y Especificidad
8.
Acta Radiol ; 52(2): 155-60, 2011 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-21498343

RESUMEN

BACKGROUND: Little is known regarding image quality and the required radiation dose for step-and-shoot and retrospective coronary computed tomography angiography (CCTA) with tube current modulation (TCM) in 128-slice multidetector CT (MDCT) coronary angiography. PURPOSE: To compare image quality and radiation dose in patients who underwent 128-slice MDCT by the step-and-shoot method with those in patients who underwent 128-slice MDCT with retrospective CCTA with TCM. MATERIAL AND METHODS: CCTA obtained with 128-slice MDCT was retrospectively evaluated in 160 patients. Two independent reviewers separately scored the subjective image quality of the coronary artery segments (1, excellent; 4, poor) for step-and-shoot (68, mean heart rate [HR]: 59.3 ± 6.8) and retrospective CCTA with TCM (77, mean HR: 59.1 ± 9.8). Interobserver variability was calculated. Effective radiation doses of both scan techniques were calculated with dose-length product. RESULTS: There was good agreement for quality scores of coronary artery segment images between the independent reviewers (κ = 0.72). The number of coronary artery segments that could not be evaluated was 2.85% (27 of 947) in the step-and-shoot and 1.87% (20 of 1071) in retrospective CCTA with TCM. Image quality scores were not significantly different (P > .05). Mean patient radiation dose was 63% lower for step-and-shoot (1.94 ± 0.70 mSv) than for retrospective CCTA with TCM (4.51 ± 1.18 mSv) (P < 0.0001). For patients who underwent step-and-shoot or retrospective CCTA with TCM, an average HR of 63.5 beats per minute was identified as the threshold for the prediction of non-diagnostic image quality for both protocols. There were no significant differences in the image quality of both methods between obese (body mass index [BMI] ≥ 25) and non-obese patients (BMI < 25), but radiation doses were higher in the obesity group than in the non-obesity group for both methods. CONCLUSION: Both step-and-shoot and retrospective CCTA with TCM using 128-slice MDCT had similar subjective image quality scores, but step-and-shoot required a lower radiation dose than retrospective CCTA with TCM.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Electrocardiografía/métodos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Medios de Contraste , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Yohexol/análogos & derivados , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Intensificación de Imagen Radiográfica/métodos
9.
Acta Radiol ; 52(8): 860-5, 2011 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-21873509

RESUMEN

BACKGROUND: With increasing awareness for radiation exposure, the study of diagnostic accuracy of coronary CT angiography (CCTA) with low radiation dose techniques is mandatory to both radiologist and clinician. PURPOSE: To compare diagnostic performance and effective radiation dose between step-and-shoot prospectively ECG-gated and retrospectively ECG-gated with tube current modulation (TCM) CCTA using 128-slice multidetector computed tomography (MDCT). MATERIAL AND METHODS: We retrospectively evaluated 60 patients who underwent CCTA with either of two different low-dose techniques using 128-slice MDCT (23 patients for step-and shoot-prospectively ECG-gated and 37 patients for retrospectively ECG-gated with TCM CCTA) followed by conventional coronary angiography. All coronary arteries and all segments thereof, except anatomical variants or small size (< 1.5 mm) ones, were included in analysis. RESULTS: In per-segment analysis, sensitivity, specificity, positive predictive value, and negative predictive value were 91/96%, 95/94%, 75/73%, and 98/99% for step-and-shoot prospectively ECG-gated and retrospectively ECG gated with TCM CCTA, respectively, relative to conventional coronary angiography. Effective radiation dose were 1.75 ± 0.83 mSv, 4.91 ± 1.71 mSv in the step-and-shoot prospectively ECG-gated and retrospectively ECG-gated with TCM CCTA groups, respectively. CONCLUSION: The two low-radiation dose CCTA techniques using 128-slice MDCT yields comparable diagnostic performance for coronary artery disease in symptomatic patients with low heart rates.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Dolor en el Pecho/diagnóstico por imagen , Angiografía Coronaria/métodos , Enfermedad Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Distribución de Chi-Cuadrado , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos , Sensibilidad y Especificidad
10.
Artículo en Inglés | MEDLINE | ID: mdl-34501812

RESUMEN

Dementia is a cognitive impairment that poses a global threat. Current dementia treatments slow the progression of the disease. The timing of starting such treatment markedly affects the effectiveness of the treatment. Some experts mentioned that the optimal timing for starting the currently available treatment in order to delay progression to dementia is the mild cognitive impairment stage, which is the prior stage of dementia. However, medical records are typically only available at a later stage, i.e., from the early or middle stage of dementia. In order to address this limitation, this study developed a model using national health information data from 5 years prior, to predict dementia development 5 years in the future. The Senior Cohort Database, comprising 550,000 samples, were used for model development. The F-measure of the model predicting dementia development after a 5-year incubation period was 77.38%. Models for a 1- and 3-year incubation period were also developed for comparative analysis of dementia risk factors. The three models had some risk factors in common, but also had unique risk factors, depending on the stage. For the common risk factors, a difference in disease severity was confirmed. These findings indicate that the diagnostic criteria and treatment strategy for dementia should differ depending on the timing. Furthermore, since the results of this study present new dementia risk factors that have not been reported previously, this study may also contribute to identification of new dementia risk factors.


Asunto(s)
Enfermedad de Alzheimer , Disfunción Cognitiva , Disfunción Cognitiva/diagnóstico , Disfunción Cognitiva/epidemiología , Progresión de la Enfermedad , Humanos , Registros Médicos
11.
Artículo en Inglés | MEDLINE | ID: mdl-34948842

RESUMEN

With the global trend toward an aging population, the increasing number of dementia patients and elderly living alone has emerged as a serious social issue in South Korea. The assessment of activities of daily living (ADL) is essential for diagnosing dementia. However, since the assessment is based on the ADL questionnaire, it relies on subjective judgment and lacks objectivity. Seven healthy seniors and six with early-stage dementia participated in the study to obtain ADL data. The derived ADL features were generated by smart home sensors. Statistical methods and machine learning techniques were employed to develop a model for auto-classifying the normal controls and early-stage dementia patients. The proposed approach verified the developed model as an objective ADL evaluation tool for the diagnosis of dementia. A random forest algorithm was used to compare a personalized model and a non-personalized model. The comparison result verified that the accuracy (91.20%) of the personalized model was higher than that (84.54%) of the non-personalized model. This indicates that the cognitive ability-based personalization showed encouraging performance in the classification of normal control and early-stage dementia and it is expected that the findings of this study will serve as important basic data for the objective diagnosis of dementia.


Asunto(s)
Actividades Cotidianas , Demencia , Anciano , Envejecimiento , Cognición , Demencia/diagnóstico , Demencia/epidemiología , Ambiente en el Hogar , Humanos
12.
Hum Immunol ; 81(12): 679-684, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32736900

RESUMEN

BACKGROUND: Angiotensin II type 1 receptor antibody (AT1R-Ab) is a non-HLA antibody that has been reported to cause antibody-mediated rejection and graft loss in kidney transplantation. The prevalence of positive AT1R-Ab varies between 8% and 18% in different regions. Thus, this study aims to determine the prevalence of AT1R-Ab among the Malaysian population. METHODOLOGY: All sera for AT1R-Ab were collected at the University Malaya Medical Centre (UMMC), Kuala Lumpur, Malaysia. The sera were centrifuged and kept refrigerated at -80 °C before being transported to the South Australian Transplantation and Immunogenetics Laboratory (SATIS). Enzyme-linked immunosorbent assay kit (One Lambda) was used for the detection of AT1R-Ab, and it was performed according to the manufacturer's instructions. The level of >17.1 U/mL was considered to be AT1R-Ab positive; 10.0-17.1 U/mL at risk, and <10.0 U/mL negative. RESULTS: A total of 115 samples were collected from 99 patients pre and post-kidney transplant recipients. From the pre-transplant sera (n = 68) 17.7% were positive, 35.3% were at risk and 47.0% were negative. The positive AT1R-Ab cohort were relatively younger, with a mean age of 34.7 ± 8.3 years old and statistically significant, with a p-value of 0.028. Among the sera that were tested positive, 19.0% were from the Chinese ethnicity, 6.7% from Malay and 16.7% from Indian. There was no difference in the rejection episodes, persistent or de novo HLA-DSA, and graft function between the group (AT1R-Ab negative vs AT1R-Ab at risk and positive) and the results were consistent in a model adjusted for all potential confounders. CONCLUSION: The prevalence of positive (>17.1 U/mL) pre-transplant AT1R-Ab was 17.7% and 35.3% were at risk (10.0-17.1 U/mL) in our pre-transplant cohort.


Asunto(s)
Autoanticuerpos/sangre , Autoanticuerpos/inmunología , Etnicidad , Rechazo de Injerto/sangre , Rechazo de Injerto/inmunología , Supervivencia de Injerto/inmunología , Trasplante de Riñón/efectos adversos , Receptor de Angiotensina Tipo 1/inmunología , Adulto , Estudios de Cohortes , Estudios Transversales , Ensayo de Inmunoadsorción Enzimática , Femenino , Antígenos HLA-DQ/sangre , Antígenos HLA-DQ/inmunología , Humanos , Malasia/etnología , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Prospectivos , Estudios Retrospectivos
13.
J Int Med Res ; 48(9): 300060520938934, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32924685

RESUMEN

OBJECTIVE: Osteoarthritis (OA) patients who undergo staged bilateral total knee arthroplasty (TKA) feel postoperative hyperalgesia in the second operated knee compared with the first knee. Ketamine is an important drug for central temporal summation and inhibition of secondary mechanical hyperalgesia. This study investigated whether central sensitization has a significant effect on hyperalgesia after consecutive operations. METHODS: Seventy-one of 80 OA patients were randomly allocated to the ketamine or saline group. A bolus of ketamine (group K) or saline (group C) (0.5 mg/kg) was injected before induction and at an infusion rate of 3 µg/kg/minute during surgery. A visual analog scale (VAS) was used to assess resting and moving pain and opioid consumption on postoperative days 1, 2, and 3. RESULTS: The difference in the VAS score between stages 1 and 2 (DV2-V1) was higher in the ketamine compared with the saline group. DV2-V1 for movement between the two groups was not inferior for all periods. Ketamine did not show a large analgesic effect on second-operated knee hyperalgesia in staged bilateral TKAs. CONCLUSIONS: We could not confirm that hyperalgesia was only related to central sensitization with low-dose ketamine. Other factors might be also associated with the hyperexcitability of nociceptive stimuli.Clinical Research Information Service (CRIS) trial registry no: KCT0001481.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Artroplastia de Reemplazo de Rodilla/efectos adversos , Sensibilización del Sistema Nervioso Central , Método Doble Ciego , Humanos , Hiperalgesia/tratamiento farmacológico , Dimensión del Dolor , Dolor Postoperatorio/tratamiento farmacológico , Dolor Postoperatorio/etiología
14.
J Cardiovasc Imaging ; 28(1): 21-32, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31805621

RESUMEN

BACKGROUND: To assess left ventricular function and coronary artery simultaneously by third-generation dual-source computed tomography (CT) using a low radiation dose. METHODS: A total of 48 patients (36 men, 12 women; mean age 57.0 ± 9.5 years) who underwent both electrocardiography-gated cardiac CT angiography (CCTA) using 70-90 kVp and echocardiography were included in this retrospective study. The correlation between left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), and left ventricular ejection fraction (LVEF) measured using CCTA and echocardiography was determined. The quality of coronary artery images was analyzed using a 4-point scale (1, excellent; 4, poor). The effective radiation dose of CCTA was calculated. RESULTS: Mean heart rate during the CT examination was 59.9 ± 9.9 bpm (range 38-79) and the body mass index of 48 patients was 24.5 ± 2.6 kg/m² (range 17.0-29.4). LVEDV, LVESV, and LVEF measured using CCTA and echocardiography demonstrated a fair to moderate correlation (Pearson correlation coefficient: r = 0.395, p = 0.005 for LVEDV; r = 0.509. p < 0.001 for LVESV; r = 0.551, p < 0.001 for LVEF). Average image quality score of coronary arteries was 1.0 ± 0.1 (range 1-2). A total of 99.0% (783 of 791) of segments had an excellent image quality score, and 1.0% (8 of 791) of segments had a good score. Mean effective radiation dose was 2.2 ± 0.7 mSv. CONCLUSIONS: Third-generation dual-source CT using a low tube voltage simultaneously provides information regarding LV function and coronary artery disease at a low radiation dose. It can serve as an alternative option for functional assessment, particularly when other imaging modalities are inadequate.

15.
Pediatr Radiol ; 39(9): 950-4, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19506848

RESUMEN

BACKGROUND: Although echocardiography is the first-line imaging modality in the diagnosis of total anomalous pulmonary venous connection (TAPVC), multidetector CT (MDCT) could have advantages in the diagnosis of TAPVC in certain cases. OBJECTIVE: To compare MDCT with echocardiography in the evaluation of TAPVC. MATERIALS AND METHODS: Enrolled in the study were 23 patients with surgically proven TAPVC. The echocardiography and MDCT findings were independently interpreted by a paediatric cardiologist and cardiac radiologist in terms of: (1) the drainage site of the common pulmonary vein, (2) stenosis of the vertical vein, and (3) the course of the atypical vessel into the systemic vein in the case of vertical vein stenosis. The findings from both modalities were correlated with the results obtained at surgery (n=22) or autopsy (n=1). RESULTS: In all patients, MDCT correctly depicted the drainage site of the common pulmonary vein, stenosis of the vertical vein and the course of the atypical vessel into the systemic vein (sensitivity 100%, specificity 100%). The specificity of echocardiography was 100% for the three defined findings. The sensitivity of echocardiography, however, was 87%, 71% and 0%, respectively. CONCLUSION: MDCT can facilitate the diagnosis of TAPVC in certain cases.


Asunto(s)
Angiografía/métodos , Flebografía/métodos , Venas Pulmonares/anomalías , Venas Pulmonares/diagnóstico por imagen , Ecocardiografía , Femenino , Humanos , Recién Nacido , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
16.
PLoS One ; 14(12): e0226369, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31821367

RESUMEN

BACKGROUND: This study was performed to determine the association between the ratio of C-reactive protein to albumin (CRP/ALB) and the risk of early allograft dysfunction (EAD) in patients undergoing living donor liver transplantation (LDLT). PATIENTS AND METHODS: A total of 588 adult patients undergoing LDLT were retrospectively investigated, after 22 were excluded because of signs of overt infection or history of ALB infusion. The study population was classified into high and low CRP/ALB ratio groups according to EAD. All laboratory variables, including CRP and ALB, had been collected on the day before surgery. A percentage value for the CRP/ALB ratio (%) was calculated as CRP/ALB × 100. RESULTS: After LDLT, 83 patients (14.1%) suffered EAD occurrence. A higher CRP/ALB ratio was independently associated with risk of EAD, Model for End-stage Liver Disease score, fresh frozen plasma transfusion, and donor age. Based on a cutoff CRP/ALB ratio (i.e., > 20%), the probability of EAD was significantly (2-fold) higher in the high versus low CRP/ALB group. The predictive utility of CRP/ALB ratio for EAD was greater than those of other inflammatory markers. In addition, patients with a high CRP/ALB ratio had poorer survival than those with a low CRP/ALB ratio during the follow-up period. CONCLUSIONS: The easily calculated CRP/ALB ratio may allow estimation of the risk of EAD after LDLT and can provide additional information that may facilitate the estimation of a patient's overall condition.


Asunto(s)
Albúminas/análisis , Aloinjertos , Proteína C-Reactiva/análisis , Rechazo de Injerto/sangre , Infecciones/sangre , Trasplante de Hígado/efectos adversos , Hígado/cirugía , Biomarcadores/sangre , Femenino , Humanos , Trasplante de Hígado/mortalidad , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
17.
J Transplant ; 2019: 9153875, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31186948

RESUMEN

BACKGROUND: The role of protocol renal allograft biopsy in kidney transplantation is controversial due to the concern with procedural-related complications; however, its role is slowly evolving. Recent evidence suggests that protocol biopsy is useful in detecting subclinical renal pathology. Early recognition and treatment of renal pathologies can improve long-term outcomes of renal allografts. METHODOLOGY: A total of 362 renal allograft protocol biopsies were performed in adult recipients of kidney transplantation between 2012 and 2017. After excluding those with poor quality or those performed with a baseline serum creatinine level >200 umol/L, we analyzed 334 (92.3%) biopsies. Histology reports were reviewed and categorized into histoimmunological and nonimmunological changes. The immunological changes were subcategorized into the following: (1) no acute rejection (NR), (2) borderline changes (BC), and (3) subclinical rejection (SCR). Nonimmunological changes were subcategorized into the following: (1) chronicity including interstitial fibrosis/tubular atrophy (IFTA), chronic T-cell-mediated rejection (TCMR), unspecified chronic lesions, and arterionephrosclerosis, (2) de novo glomerulopathy/recurrence of primary disease (RP), and (3) other clinically unsuspected lesions (acute pyelonephritis, calcineurin inhibitors toxicity, postinfective glomerulonephritis, and BK virus nephropathy). Risk factors associated with SCR were assessed. RESULTS: For the histoimmunological changes, 161 (48.2%) showed NR, 145 (43.4%) were BC, and 28 (8.4%) were SCR. These clinical events were more pronounced for the first 5 years; our data showed BC accounted for 59 (36.4%), 64 (54.2%), and 22 (40.7%) biopsies within <1 year, 1-5 years, and > 5 years, respectively (p = 0.011). Meanwhile, the incidence for SCR was 6 (3.7%) biopsies in <1 year, 18 (15.3%) in 1-5 years, and 4 (7.4%) in >5 years after transplantation (p=0.003). For the nonimmunological changes, chronicity, de novo glomerulopathy/RP, and other clinically unsuspected lesions were seen in 40 (12%), 10 (3%), and 12 (3.6%) biopsies, respectively. Living-related donor recipients were associated with decreased SCR (p=0.007). CONCLUSIONS: Despite having a stable renal function, our transplant recipients had a significant number of subclinical rejection on renal allograft biopsies.

18.
J Microbiol Biotechnol ; 18(3): 449-56, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18388461

RESUMEN

Phenotypic screening for bile salt hydrolase (BSH) activity was performed on Lactobacillus acidophilus PF01 isolated from piglet feces. A gene encoding BSH was identified and cloned from the genomic library of L. acidophilus PF01. The bsh gene and surrounding regions were characterized by nucleotide sequence analysis and were found to contain a single open reading frame (ORF) of 951 nucleotides encoding a 316 amino acid protein. The potential bsh promoter region was located upstream of the start codon. The protein deduced from the complete ORF had high similarity with other BSHs, and four amino acid motifs located around the active site, FGRNXD, AGLNF, VLTNXP, and GXGXGXXGXPGD, were highly conserved. The bsh gene was cloned into the pET21b expression vector and expressed in Escherichia coli BLR(DE3) by induction with 0.1mM of isopropylthiogalactopyranoside. The BSH enzyme was purified with apparent homogeneity using a Ni2+-NTA agarose column and characterized. The overexpressed recombinant BSH enzyme of L. acidophilus PF01 exhibited hydrolase activity against tauroconjugated bile salts, but not glycoconjugated bile salts. It showed the highest activity against taurocholic acid. The maximum BSH activity occurred at approximately 40oC. The enzyme maintained approximately 70% of its maximum activity even at 60 degrees , whereas its activity rapidly decreased at below 37 degrees . The optimum pH was 6, and BSH activity was rapidly inactivated below pH 5 and above pH 7.


Asunto(s)
Amidohidrolasas/química , Amidohidrolasas/genética , Clonación Molecular , Lactobacillus acidophilus/enzimología , Amidohidrolasas/aislamiento & purificación , Amidohidrolasas/metabolismo , Secuencia de Aminoácidos , Animales , Secuencia de Bases , Estabilidad de Enzimas , Escherichia coli/genética , Escherichia coli/metabolismo , Heces/microbiología , Expresión Génica , Lactobacillus acidophilus/genética , Datos de Secuencia Molecular , Sistemas de Lectura Abierta , Proteínas Recombinantes/química , Proteínas Recombinantes/genética , Proteínas Recombinantes/aislamiento & purificación , Proteínas Recombinantes/metabolismo , Alineación de Secuencia , Análisis de Secuencia de ADN , Homología de Secuencia de Aminoácido , Especificidad por Sustrato , Porcinos/microbiología
19.
Anat Sci Int ; 91(3): 274-9, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26272628

RESUMEN

To determine the point of entrance of the thoracic duct in the venous system, as well as to evaluate some biometric measurements concerning its terminal portion, we conducted an anatomic study on 25 non-preserved cadavers. The termination of the thoracic duct occurred on the confluence between the left internal jugular vein and the left subclavian vein in 60 % of the individuals. The average results for the biometric measurements were: distance between the end of left internal jugular vein and omohyoid muscle 31.2 ± 2.7 mm; distance between the end of thoracic duct and the left internal jugular vein 0.0 ± 0.0 mm; distance between the end of thoracic duct and the left subclavian vein 3.6 ± 1.0 mm; distance between the end of thoracic duct and the left brachiocephalic vein 10.7 ± 3.1 mm. Moreover, it was identified that the left internal jugular vein length in level IV, measured between its entrance in the left subclavian vein and the omohyoid muscle, was able to predict the termination of the thoracic duct on the junction between the left internal jugular vein and the left subclavian vein (OR = 2.99) with high accuracy (79.3 %). In addition, the left internal jugular vein length at level IV was able to predict the localization of thoracic duct termination. Thus, this finding has practical value in minimizing the risk for a potential chyle leak during or after a left-sided neck dissection.


Asunto(s)
Biometría/métodos , Cuello/anatomía & histología , Conducto Torácico/anatomía & histología , Variación Anatómica , Venas Braquiocefálicas/anatomía & histología , Cadáver , Femenino , Humanos , Venas Yugulares/anatomía & histología , Masculino , Disección del Cuello , Complicaciones Posoperatorias/prevención & control , Vena Subclavia/anatomía & histología
20.
Int J Cardiovasc Imaging ; 31 Suppl 1: 31-8, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25414055

RESUMEN

To retrospectively evaluate the image quality of CT angiography (CTA) reconstructed by model-based iterative reconstruction (MBIR) and to compare this with images obtained by filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR) in newborns and infants with congenital heart disease (CHD). Thirty-seven children (age 4.8 ± 3.7 months; weight 4.79 ± 0.47 kg) with suspected CHD underwent CTA on a 64detector MDCT without ECG gating (80 kVp, 40 mA using tube current modulation). Total dose length product was recorded in all patients. Images were reconstructed using FBP, ASIR, and MBIR. Objective image qualities (density, noise) were measured in the great vessels and heart chambers. The contrast-to-noise ratio (CNR) was calculated by measuring the density and noise of myocardial walls. Two radiologists evaluated images for subjective noise, diagnostic confidence, and sharpness at the level prior to the first branch of the main pulmonary artery. Images were compared with respect to reconstruction method, and reconstruction times were measured. Images from all patients were diagnostic, and the effective dose was 0.22 mSv. The objective image noise of MBIR was significantly lower than those of FBP and ASIR in the great vessels and heart chambers (P < 0.05); however, with respect to attenuations in the four chambers, ascending aorta, descending aorta, and pulmonary trunk, no statistically significant difference was observed among the three methods (P > 0.05). Mean CNR values were 8.73 for FBP, 14.54 for ASIR, and 22.95 for MBIR. In addition, the subjective image noise of MBIR was significantly lower than those of the others (P < 0.01). Furthermore, while FBP had the highest score for image sharpness, ASIR had the highest score for diagnostic confidence (P < 0.05), and mean reconstruction times were 5.1 ± 2.3 s for FBP and ASIR and 15.1 ± 2.4 min for MBIR. While CTA with MBIR in newborns and infants with CHD can reduce image noise and improve CNR more than other methods, it is more time-consuming than the other methods.


Asunto(s)
Angiografía Coronaria/métodos , Vasos Coronarios/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Factores de Edad , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Dosis de Radiación , Reproducibilidad de los Resultados , Estudios Retrospectivos , Relación Señal-Ruido , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA