Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 150(2): 91-101, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38742915

RESUMEN

BACKGROUND: The administration of intravenous cangrelor at reperfusion achieves faster onset of platelet P2Y12 inhibition than oral ticagrelor and has been shown to reduce myocardial infarction (MI) size in the preclinical setting. We hypothesized that the administration of cangrelor at reperfusion will reduce MI size and prevent microvascular obstruction in patients with ST-segment-elevation MI undergoing primary percutaneous coronary intervention. METHODS: This was a phase 2, multicenter, randomized, double-blind, placebo-controlled clinical trial conducted between November 2017 to November 2021 in 6 cardiac centers in Singapore. Patients were randomized to receive either cangrelor or placebo initiated before the primary percutaneous coronary intervention procedure on top of oral ticagrelor. The key exclusion criteria included presenting <6 hours of symptom onset; previous MI and stroke or transient ischemic attack; on concomitant oral anticoagulants; and a contraindication for cardiovascular magnetic resonance. The primary efficacy end point was acute MI size by cardiovascular magnetic resonance within the first week expressed as percentage of the left ventricle mass (%LVmass). Microvascular obstruction was identified as areas of dark core of hypoenhancement within areas of late gadolinium enhancement. The primary safety end point was Bleeding Academic Research Consortium-defined major bleeding in the first 48 hours. Continuous variables were compared by Mann-Whitney U test (reported as median [first quartile-third quartile]), and categorical variables were compared by Fisher exact test. A 2-sided P<0.05 was considered statistically significant. RESULTS: Of 209 recruited patients, 164 patients (78%) completed the acute cardiovascular magnetic resonance scan. There were no significant differences in acute MI size (placebo, 14.9% [7.3-22.6] %LVmass versus cangrelor, 16.3 [9.9-24.4] %LVmass; P=0.40) or the incidence (placebo, 48% versus cangrelor, 47%; P=0.99) and extent of microvascular obstruction (placebo, 1.63 [0.60-4.65] %LVmass versus cangrelor, 1.18 [0.53-3.37] %LVmass; P=0.46) between placebo and cangrelor despite a 2-fold decrease in platelet reactivity with cangrelor. There were no Bleeding Academic Research Consortium-defined major bleeding events in either group in the first 48 hours. CONCLUSIONS: Cangrelor administered at the time of primary percutaneous coronary intervention did not reduce acute MI size or prevent microvascular obstruction in patients with ST-segment-elevation MI given oral ticagrelor despite a significant reduction of platelet reactivity during the percutaneous coronary intervention procedure. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03102723.


Asunto(s)
Adenosina Monofosfato , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Masculino , Femenino , Infarto del Miocardio con Elevación del ST/terapia , Infarto del Miocardio con Elevación del ST/tratamiento farmacológico , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Persona de Mediana Edad , Método Doble Ciego , Adenosina Monofosfato/análogos & derivados , Adenosina Monofosfato/uso terapéutico , Adenosina Monofosfato/administración & dosificación , Anciano , Inhibidores de Agregación Plaquetaria/uso terapéutico , Inhibidores de Agregación Plaquetaria/administración & dosificación , Resultado del Tratamiento , Singapur , Ticagrelor/uso terapéutico , Ticagrelor/administración & dosificación
2.
Am J Physiol Heart Circ Physiol ; 319(2): H360-H369, 2020 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-32678708

RESUMEN

Proper inlet boundary conditions are essential for accurate computational fluid dynamics (CFD) modeling. We developed methodology to derive noninvasive FFRB using CFD and computed tomography coronary angiography (CTCA) images. This study aims to assess the influence of brachial mean blood pressure (MBP) and total coronary inflow on FFRB computation. Twenty-two patients underwent both CTCA and FFR measurements. Total coronary flow was computed from left ventricular mass (LVM) measured from CTCA. A total of 286 CFD simulations were run by varying MBP and LVM at 70, 80, 90, 100, 110, 120, and 130% of the measured values. FFRB increased with incrementally higher input values of MBP: 0.78 ± 0.12, 0.80 ± 0.11, 0.82 ± 0.10, 0.84 ± 0.09, 0.85 ± 0.08, 0.86 ± 0.08, and 0.87 ± 0.07, respectively. Conversely, FFRB decreased with incrementally higher inputs value of LVM: 0.86 ± 0.08, 0.85 ± 0.08, 0.84 ± 0.09, 0.84 ± 0.09, 0.83 ± 0.10, 0.83 ± 0.10, and 0.82 ± 0.10, respectively. Noninvasive FFRB calculated using measured MBP and LVM on a total of 30 vessels was 0.84 ± 0.09 and correlated well with invasive FFR (0.83 ± 0.09) (r = 0.92, P < 0.001). Positive association was observed between FFRB and MBP input values (mmHg) and negative association between FFRB and LVM values (g). Respective slopes were 0.0016 and -0.005, respectively, suggesting potential application of FFRB in a clinical setting. Inaccurate MBP and LVM inputs differing from patient-specific values could result in misclassification of borderline ischemic lesions.NEW & NOTEWORTHY While brachial mean blood pressure (MBP) and left ventricular mass (LVM) measured from CTCA are the two CFD simulation input parameters, their effects on noninvasive fractional flow reserve (FFRB) have not been systematically investigated. We demonstrate that inaccurate MBP and LVM inputs differing from patient-specific values could result in misclassification of borderline ischemic lesions. This is important in the clinical application of noninvasive FFR in coronary artery disease diagnosis.


Asunto(s)
Presión Arterial , Arteria Braquial/fisiopatología , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Ventrículos Cardíacos/diagnóstico por imagen , Modelos Cardiovasculares , Tomografía Computarizada Multidetector , Modelación Específica para el Paciente , Interpretación de Imagen Radiográfica Asistida por Computador , Anciano , Enfermedad de la Arteria Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Hidrodinámica , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos
3.
Catheter Cardiovasc Interv ; 96(7): 1423-1433, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-31769597

RESUMEN

Antegrade dissection reentry with Stingray device (Boston Scientific, Marlborough, MA) accounts for 20-34% of the chronic total occlusion (CTO) cases in the various hybrid operators' CTO registries and is an important component of CTO crossing algorithms. The Stingray device can facilitate antegrade dissection and reentry, however its use is low outside North America and Europe. The Asia Pacific CTO Club along with three experience Stingray operators from the US, Europe and India, created an algorithm guiding use of the CrossBoss and Stingray catheter. This APCTO Stingray algorithm defines when to use the CrossBoss and Stingray device recommending a reduction in CrossBoss use except for in-stent restenosis lesions and immediate transition from knuckle wiring to the Stingray device. When antegrade wiring fails, choice of Stingray-facilitated reentry versus parallel wiring depends on operator experience, device availability, cost concerns, and anatomical factors. When the antegrade wire enters the subintimal space, we recommend using a rotational microcatheter to produce a channel and deliver the Stingray balloon-so called the "bougie technique." We recommend early switch to Stingray rather than persisting with single wire redirection or parallel wire. We recommend choosing a suitable reentry zone based on preprocedural computer tomography or angiogram, routine use of stick and swap, routine use of Subintimal TRAnscatheter Withdrawal (STRAW) through the Stingray balloon, and the multi stick and swap technique. We believe these techniques and algorithm can facilitate incorporation of the Stingray balloon into the practice of CTO interventionists globally.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Oclusión Coronaria/terapia , Algoritmos , Angioplastia Coronaria con Balón/efectos adversos , Asia , Australia , Cateterismo Cardíaco/efectos adversos , Enfermedad Crónica , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/fisiopatología , Reestenosis Coronaria/etiología , Técnicas de Apoyo para la Decisión , Diseño de Equipo , Humanos , Nueva Zelanda , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
4.
Heart Lung Circ ; 29(6): 894-903, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31320259

RESUMEN

BACKGROUND: The use of a retrograde approach and algorithm-driven CTO (chronic total occlusion) percutaneous coronary intervention (PCI) has become widespread, and many registries have reported good results. This study established a new algorithm and applied it to current CTO practice and collected a CTO registry to document the results. It compared the outcomes of a retrograde versus antegrade approach in a contemporary multicentre CTO registry. METHODS: Between 1 January 2016 and 31 December 2016, consecutive patients who underwent CTO PCI performed by eight high-volume CTO operators were included in a registry. RESULTS: During this period, 485 patients with 497 CTOs were treated with technical and procedural success rates of 93.8% and 89.9%, respectively. Antegrade and retrograde technical success was 95.9% and 91.2% (p = 0.03), respectively. Procedural success for antegrade and retrograde was 94.4% and 84.6%, respectively (p < 0.001). The pure retrograde success rate was 80% and pure antegrade success rate was 75%. Technical success in different Japanese Chronic Total Occlusion (JCTO) score groups was 100% (JCTO 0), 96.2% (JCTO 1), 95.3% (JCTO 2), and 92.5% (JCTO ≥ 3), with no statistical difference in success rates between different JCTO scores. In-hospital major adverse cardiac event (MACE) was 3.8% and more common in the retrograde group (6.6% vs 1.5%). CONCLUSIONS: The retrograde approach, when used by experienced operators who have been well trained in retrograde approach, can produce higher retrograde success in complex CTO lesions. The use of an algorithm approach can improve procedural efficiency, reduce contrast and radiation dosage, and reduce the time spent in failure mode. These tools remain vital to the development of future CTO PCI.


Asunto(s)
Algoritmos , Oclusión Coronaria/cirugía , Vasos Coronarios/cirugía , Intervención Coronaria Percutánea/métodos , Sistema de Registros , Enfermedad Crónica , Angiografía Coronaria/métodos , Oclusión Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
5.
Biomed Eng Online ; 18(1): 66, 2019 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-31138235

RESUMEN

In the past few decades, imaging has been developed to a high level of sophistication. Improvements from one-dimension (1D) to 2D images, and from 2D images to 3D models, have revolutionized the field of imaging. This not only helps in diagnosing various critical and fatal diseases in the early stages but also contributes to making informed clinical decisions on the follow-up treatment profile. Carotid artery stenosis (CAS) may potentially cause debilitating stroke, and its accurate early detection is therefore important. In this paper, the technical development of various CAS diagnosis imaging modalities and its impact on the clinical efficacy is thoroughly reviewed. These imaging modalities include duplex ultrasound (DUS), computed tomography angiography (CTA) and magnetic resonance angiography (MRA). For each of the imaging modalities considered, imaging methodology (principle), critical imaging parameters, and the extent of imaging the vulnerable plaque are discussed. DUS is usually the initial recommended CAS diagnostic examination. However, for the therapeutic intervention, either MRA or CTA is recommended for confirmation, and for added information on intracranial cerebral circulation and aortic arch condition for procedural planning. Over the past few decades, the focus of CAS diagnosis has also shifted from pure stenosis quantification to plaque characterization. This has led to further advancement in the existing imaging tools and development of other potential imaging tools like Optical coherence tomography (OCT), photoacoustic tomography (PAT), and infrared (IR) thermography.


Asunto(s)
Estenosis Carotídea/diagnóstico por imagen , Diagnóstico por Imagen/métodos , Humanos
6.
Heart Lung Circ ; 28(10): 1490-1500, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31128985

RESUMEN

OBJECTIVE: Despite the advances in wire technology and development of algorithm-driven methodology for chronic total occlusion (CTO) intervention, there is a void in the literature about the technical aspects of CTO wiring. The Asia Pacific CTO Club, a group of 10 experienced operators in the Asia Pacific region, has tried to fill this void with this state-of-the-art review on CTO wiring. METHODS: This review explains, for proximal cap puncture: choices of wires, shaping of the wire, use of dual lumen catheter, and method of step-down of wire penetration force for successful wiring. In wiring the CTO body, the techniques of loose tissue tracking, intentional intimal plaque tracking, and intentional subintimal wiring are described in detail. For distal lumen wiring, a blunt distal cap, presence of a distal cap side branch, calcium, and sharp tapered distal stump predict cap toughness, and wire penetration force should be stepped-up in these cases. The importance of choosing between redirection, parallel wiring, and Stingray (Boston Scientific, Marlborough, MA, USA) for angiographic guidance is discussed along with which will be more successful. On the retrograde side, the problems encountered with distal cap puncture and methods to overcome these problems are explained. The method of wiring the CTO body through a retrograde approach depending on the morphology of the CTO is described. Different reverse controlled antegrade and retrograde tracking (CART) wiring methods - including end balloon wiring, side balloon entry, and conventional reverse CART - are explained in detail. CONCLUSION: This is a systematic CTO wiring review, which is believed to be beneficial for CTO operators worldwide.


Asunto(s)
Algoritmos , Angioplastia Coronaria con Balón/métodos , Cardiología , Oclusión Coronaria/cirugía , Intervención Coronaria Percutánea/métodos , Sociedades Médicas , Asia/epidemiología , Enfermedad Crónica , Angiografía Coronaria , Oclusión Coronaria/diagnóstico , Oclusión Coronaria/epidemiología , Humanos , Incidencia , Islas del Pacífico/epidemiología
7.
Lancet ; 387(10013): 31-9, 2016 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-26470647

RESUMEN

BACKGROUND: Absorbable scaffolds were designed to overcome the limitations of conventional, non-absorbable metal-based drug-eluting stents. So far, only polymeric absorbable scaffolds are commercially available. We aimed to assess the safety and performance of a novel second-generation drug-eluting absorbable metal scaffold (DREAMS 2G) in patients with de-novo coronary artery lesions. METHODS: We did this prospective, multicentre, non-randomised, first-in-man trial at 13 percutaneous coronary intervention centres in Belgium, Brazil, Denmark, Germany, Singapore, Spain, Switzerland, and the Netherlands. Eligible patients had stable or unstable angina or documented silent ischaemia, and a maximum of two de-novo lesions with a reference vessel diameter between 2·2 mm and 3·7 mm. Clinical follow-up was scheduled at months 1, 6, 12, 24, and 36. Patients were scheduled for angiographic follow-up at 6 months, and a subgroup of patients was scheduled for intravascular ultrasound, optical coherence tomography, and vasomotion assessment. All patients were recommended to take dual antiplatelet treatment for at least 6 months. The primary endpoint was in-segment late lumen loss at 6 months. We did analysis by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT01960504. FINDINGS: Between Oct 8, 2013, and May 22, 2015, we enrolled 123 patients with 123 coronary target lesions. At 6 months, mean in-segment late lumen loss was 0·27 mm (SD 0·37), and angiographically discernable vasomotion was documented in 20 (80%) of 25 patients. Intravascular ultrasound assessments showed a preservation of the scaffold area (mean 6·24 mm(2) [SD 1·15] post-procedure vs 6·21 mm(2) [1·22] at 6 months) with a low mean neointimal area (0·08 mm(2) [0·09]), and optical coherence tomography did not detect any intraluminal mass. Target lesion failure occurred in four (3%) patients: one (<1%) patient died from cardiac death, one (<1%) patient had periprocedural myocardial infarction, and two (2%) patients needed clinically driven target lesion revascularisation. No definite or probable scaffold thrombosis was observed. INTERPRETATION: Our findings show that implantation of the DREAMS 2G device in de-novo coronary lesions is feasible, with favourable safety and performance outcomes at 6 months. This novel absorbable metal scaffold could be an alternative to absorbable polymeric scaffolds for treatment of obstructive coronary disease. FUNDING: Biotronik AG.


Asunto(s)
Implantes Absorbibles , Antibióticos Antineoplásicos/uso terapéutico , Reestenosis Coronaria/patología , Estenosis Coronaria/terapia , Stents Liberadores de Fármacos , Sirolimus/uso terapéutico , Andamios del Tejido , Anciano , Aleaciones , Estudios de Cohortes , Reestenosis Coronaria/diagnóstico por imagen , Endosonografía , Femenino , Humanos , Magnesio , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea , Estudios Prospectivos , Tomografía de Coherencia Óptica , Resultado del Tratamiento
8.
Eur Heart J ; 37(35): 2701-9, 2016 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-27190094

RESUMEN

AIMS: Metal absorbable scaffolds constitute a conceptually attractive alternative to polymeric scaffolds. Promising 6-month outcomes of a second-generation drug-eluting absorbable metal scaffold (DREAMS 2G), consisting of an absorbable magnesium scaffold backbone, have been reported. We assessed the 12-month safety and performance of this novel device. METHODS AND RESULTS: The prospective, international, multi-centre, first-in-man BIOSOLVE-II trial enrolled 123 patients with up to two de novo lesions with a reference diameter between 2.2 and 3.7 mm. All patients were scheduled for angiographic follow-up at 6 months, and-if subjects consented-at 12 months. Dual antiplatelet therapy was recommended for 6 months. Quantitative coronary angiography (QCA) parameters remained stable from 6 to 12 months [paired data of 42 patients: in-segment late lumen loss 0.20 ± 0.21 mm vs. 0.25 ± 0.22 mm, P = 0.117, Δ 0.05 ± 0.21 mm (95% CI: -0.01;0.12); in-scaffold late lumen loss 0.37 ± 0.25 mm vs. 0.39 ± 0.27 mm, P = 0.446, Δ 0.03 ± 0.22 (95% CI: -0.04;0.10), respectively]. Intravascular ultrasound and optical coherence tomography findings corroborated the QCA results. Target lesion failure occurred in four patients (3.4%), consisting of one death of unknown cause, one target-vessel myocardial infarction, and two clinically driven target lesion revascularization. No additional event occurred beyond the 6-month follow-up. During the entire follow-up of 12 months, none of the patients experienced a definite or probable scaffold thrombosis. CONCLUSION: The novel drug-eluting metal absorbable scaffold DREAMS 2G showed a continuous favourable safety profile up to 12 months and stable angiographic parameters between 6 and 12 months. CLINICALTRIALSGOV IDENTIFIER: NCT01960504.


Asunto(s)
Stents Liberadores de Fármacos , Implantes Absorbibles , Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Humanos , Metales , Estudios Prospectivos , Sirolimus , Resultado del Tratamiento
9.
Am Heart J ; 169(6): 899-905.e1, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26027629

RESUMEN

BACKGROUND: In the PLATO trial, ticagrelor was superior to clopidogrel in reducing cardiovascular events among patients with acute coronary syndrome (ACS) at the expense of increased nonfatal bleeding. Because Asian patients, when compared with non-Asian patients, are believed to be more susceptible to bleeding, we evaluated the effects of ticagrelor compared with clopidogrel in Asian (n=1,106) and non-Asian (n=17,515) patients with acute coronary syndrome enrolled in the PLATO study. METHODS AND RESULTS: Interaction between Asian/non-Asian and primary efficacy end point (a composite of vascular death, myocardial infarction, and stroke) and net clinical benefit (composite of primary efficacy end point and coronary artery bypass graft [CABG] surgery or non-CABG-related major bleeding) were evaluated with a Cox proportional hazards model. Baseline demographics and comorbidities were different between Asians and non-Asians. The overall cardiovascular event rates were higher in Asians, but bleeding rates were similar. Despite these observed differences, the effects of ticagrelor versus clopidogrel were not significantly different between Asians and non-Asians with respect to the primary efficacy outcome (hazard ratio for Asians vs non-Asians, 0.84 [95% CI 0.61-1.17] vs 0.85 [95% CI 0.77-0.93], P=.974), net clinical benefit (0.85 [95% CI 0.65-1.11] vs 0.93 [95% CI 0.86-0.99], P=.521), or individual efficacy end points. There was no significant interaction for bleeding (PLATO major bleeding, 1.02 [95% CI 0.70-1.49] vs 1.04 [95% CI 0.95-1.14], P=.938) and other related adverse events with ticagrelor compared with clopidogrel between Asians and non-Asians. CONCLUSIONS: We observed consistency of effects in Asian patients receiving ticagrelor and clopidogrel in the PLATO study. The relatively modest number of Asian patients in this analysis supports further investigation of larger cohorts to confirm our observations.


Asunto(s)
Síndrome Coronario Agudo/tratamiento farmacológico , Síndrome Coronario Agudo/etnología , Adenosina/análogos & derivados , Pueblo Asiatico , Inhibidores de Agregación Plaquetaria/uso terapéutico , Antagonistas del Receptor Purinérgico P2Y/uso terapéutico , Ticlopidina/análogos & derivados , Adenosina/efectos adversos , Adenosina/uso terapéutico , Anciano , Clopidogrel , Método Doble Ciego , Femenino , Hemorragia/inducido químicamente , Humanos , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/efectos adversos , Antagonistas del Receptor Purinérgico P2Y/efectos adversos , Estudios Retrospectivos , Ticagrelor , Ticlopidina/efectos adversos , Ticlopidina/uso terapéutico , Resultado del Tratamiento
10.
J Invasive Cardiol ; 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38718282

RESUMEN

A 65-year-old man with end-stage renal failure, severe aortic stenosis, and triple vessel coronary artery disease was admitted for percutaneous coronary intervention to the left anterior descending artery prior to transcatheter aortic valve replacement.

11.
J Invasive Cardiol ; 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38471152

RESUMEN

A 73-year-old female presented with exertional dyspnea and was found to have a coronary artery to pulmonary artery fistula with 2 sequential giant aneurysms. Her chest radiograph showed a mass above the cardiac silhouette.

12.
AsiaIntervention ; 10(1): 51-59, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38425806

RESUMEN

Background: The use of cerebral embolic protection devices during transcatheter aortic valve implantation (TAVI) reveals conflicting data. Aims: This updated meta-analysis aims to evaluate the efficacy and safety of the SENTINEL Cerebral Protection System. Methods: A literature search for relevant studies up to September 2022 was performed. Study outcomes were divided based on time period - overall (up to 30 days) and short (≤7 days). The outcomes studied include stroke (disabling, non-disabling), mortality, neuroimaging findings, transient ischaemic attack, acute kidney injury and major vascular and bleeding complications. Results: A total of 15 studies involving 294,134 patients were included. Regarding overall outcomes, significant reductions were noted for mortality (odds ratio [OR] 0.60, 95% confidence interval [CI]: 0.41-0.88; p=0.008), all stroke (OR 0.64, 95% CI: 0.46-0.88; p=0.006) and disabling stroke (OR 0.42, 95% CI: 0.23-0.74; p=0.003) using the SENTINEL device. No significant differences were noted for other outcomes. There was significant heterogeneity across the studies for mortality (p=0.013) and all stroke (p=0.003). Including only randomised data (n=4), there was only significant reduction in the incidence of disabling stroke (OR 0.39, 95% CI: 0.17-0.89; p=0.026) in the SENTINEL group. In studies reporting ≤7-day outcomes (n=8), use of the SENTINEL device demonstrated significantly lower rates of all stroke (p<0.001), disabling stroke (p<0.001) and major bleeding complications (p=0.02). No differences in neuroimaging outcomes were noted. Conclusions: In this updated meta-analysis, use of the SENTINEL Cerebral Protection System was associated with lower rates of mortality, all stroke and disabling stroke, although significant heterogeneity was noted for mortality and all stroke. Including exclusively randomised data, there was only significant reduction in the incidence of disabling stroke. No significant adverse outcomes with device use were noted.

13.
Am J Cardiol ; 200: 135-143, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37321026

RESUMEN

The availability of direct oral anticoagulants (DOACs) with known lower bleeding risk compared with warfarin have raised questions about the role of left atrial appendage closure (LAAC). We aimed to perform a meta-analysis to compare the clinical outcomes for LAAC versus DOACs. All studies directly comparing LAAC with DOACs up to January 2023 were included. The outcomes studied included the combined major adverse cardiovascular (CV) events outcomes, ischemic stroke and thromboembolic events, major bleeding, CV mortality, and all-cause mortality. Hazard ratios (HRs) and their 95% confidence interval were extracted or estimated from the data and pooled together with a random-effects model. A total of 7 studies (1 randomized controlled trial, 6 propensity-matched observational studies) were finally included, with a pooled population of 4,383 patients who underwent LAAC and 4,554 patients on DOACs. There were no significant differences between patients who underwent LAAC and patients on DOACs in terms of baseline age (75.0 vs 74.7, p = 0.27), CHA2DS2-VASc score (5.1 vs 5.1, p = 0.33), or HAS-BLED score (3.3 vs 3.3, p = 0.36). After a mean weighted follow-up of 22.0 months, LAAC was associated with significantly lower rates of combined major adverse CV event outcomes (HR 0.73 [0.56 to 0.95], p = 0.02), all-cause mortality (HR 0.68 [0.54 to 0.86], p = 0.02), and CV mortality (HR 0.55 [0.41 to 0.72], p<0.01). There were no significant differences in the rates of ischemic stroke or systemic embolism (HR 1.12 [0.92 to 1.35], p = 0.25), major bleeding (HR 0.94 [0.67 to 1.32], p = 0.71), or hemorrhagic stroke (HR 1.07 [0.74 to 1.54], p = 0.74) between LAAC and DOAC. In conclusion, percutaneous LAAC was found to be as efficacious as DOACs for stroke prevention, with lower all-cause and CV mortality. The rates of major bleeding and hemorrhagic stroke were similar. LAAC has a potential role to play in stroke prevention in patients with atrial fibrillation in the era of DOACs, but further randomized data are needed.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular Hemorrágico , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/epidemiología , Anticoagulantes/uso terapéutico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Apéndice Atrial/cirugía , Hemorragia/inducido químicamente , Accidente Cerebrovascular Isquémico/complicaciones , Resultado del Tratamiento , Ensayos Clínicos Controlados Aleatorios como Asunto
14.
Am J Cardiol ; 205: 369-378, 2023 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-37639763

RESUMEN

Patients with chronic kidney disease (CKD) have traditionally been excluded from randomized trials. We aimed to compare percutaneous coronary intervention versus conservative management, and early intervention (EI; within 24 hours of admission) versus delayed intervention (DI; after 24 to 72 hours of admission) in patients with non-ST-segment elevation myocardial infarction (NSTEMI) and concomitant CKD. An electronic literature search was performed to search for studies comparing invasive management to conservative management or EI versus DI in patients with NSTEMI with CKD. The primary outcome was all-cause mortality; secondary outcomes were acute kidney injury (AKI) or dialysis, major bleeding, and recurrent MI. Hazard ratios (HRs) for the primary outcome and odds ratios for secondary outcomes were pooled in random-effects meta-analyses. Eleven studies (140,544 patients) were analyzed. Invasive management was associated with lower mortality than conservative management (HR 0.62, 95% confidence interval 0.57 to 0.67, p <0.001, I2 = 47%), with consistent benefit across all CKD stages, except CKD 5. There was no significant mortality difference between EI and DI, but subgroup analyses showed significant benefit for EI in stage 1 to 2 CKD (HR 0.75, 95% confidence interval 0.58 to 0.97, p = 0.03, I2 = 0%), with no significant difference in stage 3 and 4 to 5 CKD. Invasive strategy was associated with higher odds of AKI or dialysis and major bleeding, but lower odds of recurrent MI compared with conservative management. In conclusion, in patients with NSTEMI and CKD, an invasive strategy is associated with significant mortality benefit over conservative management in most patients with CKD, but at the expense of higher risk of AKI and bleeding. EI appears to benefit those with early stages of CKD. Trial Registration: PROSPERO CRD42023405491.


Asunto(s)
Lesión Renal Aguda , Infarto del Miocardio sin Elevación del ST , Insuficiencia Renal Crónica , Infarto del Miocardio con Elevación del ST , Humanos , Infarto del Miocardio sin Elevación del ST/complicaciones , Infarto del Miocardio sin Elevación del ST/terapia , Lesión Renal Aguda/epidemiología , Lesión Renal Aguda/etiología , Tratamiento Conservador , Hospitalización , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/epidemiología
15.
JACC Cardiovasc Imaging ; 16(8): 1022-1034, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37052561

RESUMEN

BACKGROUND: Current cardiac magnetic resonance (CMR) imaging in pulmonary arterial hypertension (PAH) focuses on measures of ventricular function and coupling. OBJECTIVES: The purpose of this study was to evaluate pulmonary artery (PA) global longitudinal strain (GLS) as a prognostic marker in patients with PAH. METHODS: The authors included 169 patients with PAH from the ASPIRE (Assessing the Spectrum of Pulmonary hypertension Identified at a REferral centre) and INITIATE (Integrated computatioNal modelIng of righT heart mechanIcs and blood flow dynAmics in congeniTal hEart disease) registries, and 82 normal controls with similar age and gender distributions. PA GLS was derived from CMR feature tracking. Right ventricular measurements including volumes, ejection fraction, and right ventricular GLS were also derived from CMR. Patients were followed up a median of 34 months with all-cause mortality as the primary endpoint. Other known risk scores were collected, including the REVEAL (Registry to Evaluate Early and Long-term Pulmonary Arterial Hypertension Disease Management) 2.0 and COMPERA (Comparative, Prospective Registry of Newly Initiated Therapies for Pulmonary Hypertension) 2.0 scores. RESULTS: Of 169 patients (mean age: 57 ± 15 years; 80% female), 45 (26.6%) died (median follow-up: 34 months). Mean PA GLS was 23% ± 6% in normal controls and 10% ± 5% in patients with PAH (P < 0.0001). Patients with PA GLS <9% had a higher risk of mortality than those with PA GLS ≥9% (P < 0.001), and this was an independent predictor of mortality in PAH on multivariable analysis after adjustment for known risk factors (HR: 2.93; P = 0.010). Finally, in patients with PAH, PA GLS provided incremental prognostic value over the REVEAL 2.0 (global chi-square; P = 0.001; C statistic comparison; P = 0.030) and COMPERA 2.0 (global chi-square; P = 0.001; C statistic comparison; P = 0.048). CONCLUSIONS: PA GLS confers incremental prognostic utility over the established risk scores for identifying patients with PAH at higher risk of death, who may be targeted for closer monitoring and/or intensified therapy.


Asunto(s)
Hipertensión Pulmonar , Hipertensión Arterial Pulmonar , Humanos , Femenino , Adulto , Persona de Mediana Edad , Anciano , Masculino , Hipertensión Arterial Pulmonar/diagnóstico por imagen , Arteria Pulmonar/diagnóstico por imagen , Hipertensión Pulmonar/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Valor Predictivo de las Pruebas , Hipertensión Pulmonar Primaria Familiar , Pronóstico , Volumen Sistólico
16.
Radiol Cardiothorac Imaging ; 5(6): e230064, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38166346

RESUMEN

Purpose To develop a new coronary CT angiography (CCTA)-based index, α×LL/MLD4, that considers lesion entrance angle (α) in addition to lesion length (LL) and minimal lumen diameter (MLD) and to evaluate its efficacy in predicting hemodynamically significant coronary stenosis compared with invasive coronary angiography (ICA)-derived fractional flow reserve (FFR). Materials and Methods This prospective study enrolled participants (September 2016-March 2020) from two centers who underwent CCTA followed by ICA (ClinicalTrials.gov identifier: NCT03054324). CCTA images were processed semiautomatically to measure LL, MLD, and α for calculating α×LL/MLD4. Diagnostic performance and accuracy of α×LL/MLD4 and LL/MLD4 in detecting hemodynamically significant coronary stenosis were compared against the reference standard (invasive FFR ≤ 0.80). Results In total, 133 participants (mean age, 63 years ± 9 [SD]; 99 [74%] men) with 210 stenosed coronary arteries were analyzed. Median α×LL/MLD4 was 54.0 degree/mm3 (IQR, 25.3-128.7) in participants with invasive FFR of 0.80 or less and 6.7 degree/mm3 (IQR, 3.3-12.8) in participants with invasive FFR of more than 0.80 (P < .001). The per-vessel accuracy, sensitivity, specificity, positive predictive value, and negative predictive value for discriminating ischemic lesions were 86.2%, 83.1%, 88.4%, 84.1%, and 87.7% for α×LL/MLD4 and 80.5%, 66.3%, 90.9%, 84.3%, and 78.6% for LL/MLD4, respectively. Area under the receiver operating characteristic curve for discriminating hemodynamically significant stenosis was 0.93 for α×LL/MLD4, which was significantly greater than the values of 0.84 for LL/MLD4 and 0.63 for diameter stenosis (both P < .001). Conclusion The new morphologic index, α×LL/MLD4, incorporating lesion entrance angle achieved higher diagnostic performance in detecting hemodynamically significant lesions compared with diameter stenosis and LL/MLD4. Keywords: CT Angiography, Cardiac, Coronary Arteries, Ischemia, Infarction, Technology Assessment Clinical trial registration no. NCT03054324 Supplemental material is available for this article. © RSNA, 2023 See also the commentary by Fairbairn and Nørgaard in this issue.


Asunto(s)
Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Angiografía por Tomografía Computarizada/métodos , Constricción Patológica , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico , Estudios Prospectivos , Estudios Retrospectivos , Anciano
17.
Int J Cardiol ; 348: 9-14, 2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-34864078

RESUMEN

BACKGROUND: Physician visual assessment (PVA) in invasive coronary angiography (ICA) is the current clinical method to determine stenosis severity and guide percutaneous coronary intervention. This study sought to evaluate the effect of sex differences in assessing coronary stenosis severity between PVA and quantitative coronary angiography (QCA). METHODS: 209 patients with coronary artery disease (288 coronary lesions) underwent ICA and fractional flow reserve (FFR). ICA image processing including PVA and QCA was used to quantify diameter stenosis (DS). The difference of DS (ΔDS) between PVA and QCA was defined as DSPVA-DSQCA. DS ≥50% was considered anatomically obstructive. FFR ≤0.8 was defined as myocardial ischemia. RESULTS: Mean ± SD age was 63 ± 9 years. There were no significant differences in DSPVA (61.1 ± 16.3% vs 60.1 ± 18.9%) and DSQCA (53.1 ± 12.1% vs 55.4 ± 14.3%) between females and males. However, ΔDS between PVA and QCA was higher in females (8.0 ± 10.9%) than in males (4.7 ± 10.9%) (P = 0.03). Thirty-four of 72 vessels (47.2%) in female patients and 75 of 216 vessels (34.7%) in male patients were classified differently by at least one grade using PVA compared to QCA assessment. DSPVA and DSQCA were negatively correlated with FFR in females (rPVA = -0.397, rQCA = -0.448) with an even stronger negative correlation in males (rPVA = -0.607, rQCA = -0.607). ROC analysis demonstrated that DSQCA had better discrimination capability for myocardial ischemia (FFR ≤ 0.80) than DSPVA in both sexes (P < 0.05). CONCLUSIONS: A systematic bias was found in PVA (QCA reference) for overestimating severity of coronary artery disease in females compared to males.


Asunto(s)
Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Médicos , Anciano , Constricción Patológica , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Caracteres Sexuales
18.
Cardiovasc Revasc Med ; 38: 106-110, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34364807

RESUMEN

BACKGROUND: Permanent drug-eluting stents are associated with a steady increase in late complications attributed to persistent inflammation and poor vessel remodelling. Bioresorbable scaffolds have been developed to overcome such long-term limitations by providing temporary vessel support and disappearing thereafter. We aimed to assess the long-term outcomes of an absorbable metallic scaffold at 5 years. METHODS: BIOSOLVE-II is an international, multi-centre, first-in-human study assessing the safety and performance of the sirolimus-eluting absorbable metal scaffold DREAMS 2G (commercial name Magmaris) in patients with a maximum of two de novo lesions. After 3 years, follow-up was extended to 5 years with the endpoints of target lesion failure and rate of definite or probable stent thrombosis. RESULTS: A total of 123 patients with 123 lesions were enrolled. Lesions were 12.6 ± 4.5 mm long and 2.7 ± 0.4 mm in diameter, 43.4% were class B2/C lesions, and calcification was moderate to severe in 10.6%. At 5 years, 5.4% of patients had stable angina and 94.6% had no symptoms or ischaemia. Target lesion failure rate was 8.0% [95% confidence interval:4.2;14.9], reflecting 2 cardiac deaths, 2 target-vessel myocardial infarctions, and 6 clinically driven target lesion revascularizations (TLRs). Only one target lesion failure occurred beyond 3 years: a target-vessel myocardial infarction with clinically driven TLR on post-procedure day 1157. One additional non-cardiac death beyond 3 years due to renal failure was reported on day 1777. No definite or probable scaffold thrombosis was observed. CONCLUSION: The Magmaris scaffold showed favourable long-term safety and clinical performance with low target lesion failure rates and absence of definite or probable scaffold thrombosis throughout 5 years.


Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Implantes Absorbibles , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Humanos , Metales , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Estudios Prospectivos , Sirolimus/efectos adversos , Resultado del Tratamiento
19.
Ann Acad Med Singap ; 51(10): 605-618, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36317571

RESUMEN

INTRODUCTION: Data on patients with small aortic annuli (SAA) undergoing transcatheter aortic valve implantation (TAVI) are limited. We aim to describe the impact of aortic annular size, particularly SAA and TAVI valve type on valve haemodynamics, durability and clinical outcomes. METHOD: All patients in National Heart Centre Singapore who underwent transfemoral TAVI for severe symptomatic native aortic stenosis from July 2012 to December 2019 were included. Outcome measures include valve haemodynamics, prosthesis-patient mismatch (PPM), structural valve degeneration (SVD) and mortality. RESULTS: A total of 244 patients were included. The mean Society of Thoracic Surgeons score was 6.22±6.08, with 52.5% patients with small aortic annulus (<23mm), 33.2% patients with medium aortic annulus (23-26mm) and 14.3% patients with large aortic annulus (>26mm). There were more patients with self-expanding valve (SEV) (65.2%) versus balloon-expandable valve (BEV) (34.8%). There were no significant differences in indexed aortic valve area (iAVA), mean pressure gradient (MPG), PPM, SVD or mortality across all aortic annular sizes. However, specific to the SAA group, patients with SEV had larger iAVA (SEV 1.19±0.35cm2/m2 vs BEV 0.88±0.15cm2/m2, P<0.01) and lower MPG (SEV 9.25±4.88 mmHg vs BEV 14.17±4.75 mmHg, P<0.01) at 1 year, without differences in PPM or mortality. Aortic annular size, TAVI valve type and PPM did not predict overall mortality up to 7 years. There was no significant difference in SVD between aortic annular sizes up to 5 years. CONCLUSION: Valve haemodynamics and durability were similar across the different aortic annular sizes. In the SAA group, SEV had better haemodynamics than BEV at 1 year, but no differences in PPM or mortality. There were no significant differences in mortality between aortic annular sizes, TAVI valve types or PPM.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Diseño de Prótesis , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/cirugía , Resultado del Tratamiento , Hemodinámica
20.
Eur Heart J Case Rep ; 5(5): ytab173, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-34124571

RESUMEN

BACKGROUND: Despite improvement in available tools and techniques, procedural complications like coronary perforation can occur during percutaneous coronary intervention (PCI). Severe proximal coronary perforations are usually caused by balloon and vessel size mismatch but can also occur with appropriately sized balloons or stents if the coronary vessel has very eccentric calcification or if there is negative remodelling of the vessel. CASE SUMMARY: A 74-year-old man with a history of type II diabetes mellitus, hypertension, and chronic coronary syndrome (previous PCI 10 years before) presented with unstable angina of 2 weeks of duration. Coronary angiography revealed a patent stent in left anterior descending artery, significant disease in left circumflex artery and diffuse calcified lesion in dominant right coronary artery (RCA). During angioplasty of RCA, the patient developed severe Ellis grade III perforation, which was successfully managed with modified double guiding catheter 'Ping Pong' technique. In this technique, the already engaged 7 French (F) Amplatz Left 1 guide catheter was used to deliver the bulky covered stent in highly tortuous and calcified RCA while a second 6F guide catheter (Judkin Right) introduced through contralateral femoral access was used for introducing the balloon, which initially sealed the perforation and subsequently acted as a distal anchor to provide strong support to deliver the covered stent. CONCLUSION: In a case of severe coronary perforation, modified Ping Pong technique using a small-sized second guide catheter complimentary to the first guide catheter, can be used to deploy bulky covered stent.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA