Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
Más filtros

Intervalo de año de publicación
1.
Int Endod J ; 54(6): 966-974, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33527413

RESUMEN

AIM: To evaluate the correlation between the volume of dental hard tissues removed and the fracture resistance of mandibular molar teeth with ultraconservative (UltraAC) or traditional (TradAC) access cavity preparations. METHODOLOGY: Sixty recently extracted and intact mandibular first molars were scanned in a microcomputed tomographic (micro-CT) device, anatomically matched and assigned at random to 2 groups (n = 30), according to the access cavity type: UltraAC or TradAC. After access preparation, mesial and distal canals were prepared using Reciproc instruments and a new scan was taken. The volumes of pulp chamber and dental hard tissues in each specimen were measured before and after the experimental procedures, and the percentage volume reduction of hard tissues calculated for the entire tooth and for the crown separately. Teeth were then root filled, restored and subjected to fracture resistance tests in an universal testing machine. The force required to fracture was recorded in Newtons (N). The adherence of the variables to a Gaussian curve was verified using a Shapiro-Wilk test. Skewed data were analysed with nonparametric Wilcoxon signed rank or Spearman correlation tests, whilst the normally distributed data were analysed with a dependent samples Student t-test. Level of significance was set at 5%. RESULTS: Pre-operatively, no difference was observed between groups regarding the volume of pulp canal space or dental hard tissues (P > 0.05). After access preparation, volumes of the removed hard tissues from the entire tooth and from the crown were significantly greater in teeth prepared with TradAC than with UltraAC (P < 0.05). No significant difference was observed in the fracture resistance values between TradAC (902.9 ± 347.8 N) and UltraAC (948.7 ± 405.7 N) groups (P = 0.975). The Spearman test was unable to identify a correlation between fracture resistance and percentage volume of removed dental hard tissues in the entire root (P = 0.525, r = -0.084) or only in the crown (P = 0.152, r = -0.187). CONCLUSION: The volume of hard dental tissues removed, although greater in teeth with TradAC compared to UltraAC, did not correlate with the fracture resistance results, indicating that a minimally invasive access cavity did not increase the resistance of restored mandibular first molars to fracture.


Asunto(s)
Diente Molar , Preparación del Conducto Radicular , Cavidad Pulpar , Dentina , Humanos , Diente Molar/diagnóstico por imagen , Diente Molar/cirugía , Microtomografía por Rayos X
2.
Int Endod J ; 54(8): 1383-1393, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33811762

RESUMEN

AIM: To evaluate the influence of ultraconservative access cavities (UltraAC) on canal shaping and filling ability and load capacity of mandibular molars after root canal preparation with XP-endo Shaper (XP) or Reciproc (RC), under simulated clinical conditions. Traditional access cavities (TradAC) were used for comparison. METHODOLOGY: Forty extracted mandibular molars were scanned by micro-computed tomographic and, based on similar anatomical features, were divided into four groups (n = 10), according to the type of access cavity and canal instrumentation protocol: TradAC/RC, TradAC/XP, UltraAC/RC and UltraAC/XP. All root canal procedures were performed with the teeth placed in a dental mannequin. Teeth were scanned after root canal instrumentation and filling. Unprepared canal area, dentine removed, accumulated hard tissue debris (AHTD), canal transportation, presence of voids and filling material remnants within the pulp chamber were analysed. After restorative procedures, the teeth were subjected to thermomechanical cycling and to a load capacity test. Statistical analyses were performed using two-way anova test, considering the randomized blocks design (P < 0.05). RESULTS: The percentage of unprepared canal area was significantly lower in TradAC groups when compared to UltraAC groups (P < 0.05), regardless of the instrument used. The UltraAC/XP group had significantly lower percentage of root dentine removed when compared to other groups (P < 0.05). UltraAC/XP and TradAC/XP groups had significantly lower percentages of AHTD than UltraAC/RC and TradAC/RC groups (P < 0.05). Regarding canal transportation, in the MB root canals, the TradAC/XP group had significantly lower values than other groups (P < 0.05). In general, in ML and distal root canals, TradAC/XP and UltraAC/XP groups had significantly lower values of canal transportation when compared to other groups (P < 0.05). Moreover, the UltraAC/RC had the greatest canal transportation values in MB and distal canals. The UltraAC groups had significantly greater percentages of voids and volume of remaining root filling material within the pulp chamber after cleaning procedures than TradAC groups (P < 0.05). There was no difference in the load capacity amongst groups (P < 0.05). CONCLUSION: The UltraAC/XP and UltraAC/RC groups had significantly greater areas of unprepared canal walls, significantly more voids and volume of root filling material remnants within the pulp chamber after canal filling. UltraAC/XP was associated with significantly less root dentine removal and significantly more AHTD whilst TradAC/XP had overall significantly less canal transportation. No differences were observed in the load capacity amongst groups.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Diente Molar/diagnóstico por imagen , Diente Molar/cirugía , Obturación del Conducto Radicular , Microtomografía por Rayos X
3.
Int Endod J ; 54(2): 279-293, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32920829

RESUMEN

AIM: To validate a new method for the evaluation of pulp tissue debridement in the root canals of extracted teeth using an impregnation protocol involving potassium triiodide, a radiocontrast solution known as Lugol's, combined with micro-computed tomographic (micro-CT) imaging. METHODOLOGY: The impact of NaOCl on the radiopacity of Lugol's solution was assessed using a two-fold dilution series of Lugol in distilled water and 5.25% NaOCl, which were then pipetted into transparent dishes and radiographed. To verify the influence of Lugol on the proteolytic effect of NaOCl, a dissolution test was performed using fresh bovine meat. Ten slices did not undergo any tissue processing, whilst twenty slices were fixed in formaldehyde for 24 h. After that, 10 of them were immersed in Lugol for another 24 h. Then, all specimens were placed in NaOCl and the time required for a complete tissue dissolution was recorded. For the last experiments (histological validation and micro-CT assessment), 8 extracted mandibular premolars with formerly vital pulps were immersed in buffered formalin, scanned in a micro-CT device, accessed, immersed in Lugol for 7 days and scanned again. Then, the root canals of 5 teeth were prepared and scanned, and the volume of remaining pulp tissue identified and quantified, whilst 3 teeth were histologically processed. The same specimens were subjected to histological assessment, and the images of the histologic sections were registered with the corresponding micro-CT images to verify whether the pulp tissue in the histological sections matched its counterpart in the Lugol-impregnated tissues identified in the micro-CT slices. RESULTS: There was no discernible effect on radiopacity when NaOCl was mixed with Lugol's solution. Tissue processing did not affect the time required for the complete dissolution of fresh bovine meat. Histological evaluation revealed a correlation between micro-CT and histological images confirming the identification of Lugol-impregnated pulp tissue in micro-CT images. CONCLUSIONS: The radiocontrast Lugol's solution was unaffected by NaOCl and did not interfere with its soft tissue dissolution capability. The impregnation protocol using Lugol's solution allowed the visualization of pulp tissue on the micro-CT images and the identification of pulp remnants after chemical-mechanical canal procedures.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Animales , Bovinos , Desbridamiento , Pulpa Dental , Cavidad Pulpar/diagnóstico por imagen , Microtomografía por Rayos X
4.
Int Endod J ; 53(11): 1559-1568, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32767773

RESUMEN

AIM: To evaluate the viability of the electrochemical dissolution of fragments of fractured NiTi instruments in root canals of extracted human maxillary molars, using two electrodes and the solution restricted to a small reservoir coupled to the pulp chamber. The primary hypothesis was that this method enables the reduction of fragment volume and re-establishment of the root canal path with a size 08 K-file, both in simulated canals and in extracted human maxillary molars. METHODOLOGY: Fragments of F1 ProTaper instruments were polarized in simulated root canals and in distobuccal root canals of extracted maxillary molars using a new method, with the solution restricted to a small acrylic microcell coupled to each resin block or pulp chamber. Two electrodes were used, where one was kept in contact with the intracanal fragment and another was positioned in the solution present in the acrylic microcell. After the tests, a size 08 K-file was used passively to verify the possibility of bypassing the fragment, which was also confirmed by radiographic analysis. Micro-CT analysis of the teeth was used before and after fragment dissolution to evaluate the volume, length and porosity of the fragments. The D'Agostino-Pearson normality test was used to verify the distribution of the data. A paired t-test (P < 0.05) was used to compare the volume, length and porosity of the fragments before and after the dissolution tests. RESULTS: After dissolution, all fragments could be bypassed with a size 08 K-file in both simulated canals and in extracted teeth. The dissolution process did not result in significant reduction of neither the fragment length nor the fragment porosity. However, it resulted in a significant reduction of fragment volume (paired t-test, P < 0.05). CONCLUSION: The electrochemical dissolution of fragments of NiTi files in root canals of extracted human maxillary molars using two electrodes, and the solution restricted to a small reservoir coupled to the pulp chamber resulted in a significant reduction of fragment volume. The re-establishment of the root canal path with the passive insertion of size 08 K-files was possible in all samples after the tests, both in simulated canals and in extracted teeth.


Asunto(s)
Cavidad Pulpar , Níquel , Aleaciones Dentales , Electrólitos , Humanos , Diente Molar/diagnóstico por imagen , Preparación del Conducto Radicular , Solubilidad , Titanio
5.
Int Endod J ; 53(3): 410-420, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31613994

RESUMEN

AIM: To investigate the shaping and cleaning performance of the Clearsonic ultrasonic tip as a supplementary tool during the preparation of long oval-shaped root canals through micro-computed tomographic (micro-CT) imaging technology. The Reciproc M-Wire R40 instrument was used as a reference instrumentation technique for comparison. METHODOLOGY: Twenty mandibular incisors with single, straight and long oval-shaped canals were selected and pair-matched by micro-CT scanning. The root canals were prepared with Reciproc R25 and R40 instruments, scanned again in a micro-CT device and randomly allocated into one of the two experimental groups (n = 10), according to the supplementary debridement protocol used: Clearsonic or Reciproc R40 used in a brushing motion against buccal and lingual walls. Noninstrumented canal areas, accumulation of hard-tissue debris (AHTD) and volume of removed dentine were assessed using micro-CT imaging following the supplementary debridement protocols. Data were analysed statistically in two phases using a t-test with a significance level of 5%. RESULTS: In phase-1, there was a significant similarity between the samples regarding the evaluated micro-CT baseline parameters (P > 0.05), validating the anatomical similarity between the tooth pairs. In phase-2, there was a significant difference between the groups for canal volume, surface area, noninstrumented root canal walls and the amount of removed dentine for both absolute and percentage values (P < 0.05), but not for AHTD (P = 0.759). CONCLUSIONS: The Clearsonic tip outperformed the Reciproc R40 instrument as a supplementary debridement protocol as it was associated with significantly greater reduction of noninstrumented root canals walls and consequently a larger amount of removed dentine. Both groups performed similarly regarding the AHTD.


Asunto(s)
Preparación del Conducto Radicular , Desbridamiento , Cavidad Pulpar , Diseño de Equipo , Ultrasonido , Microtomografía por Rayos X
6.
Int Endod J ; 53(2): 265-275, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31519039

RESUMEN

AIM: To evaluate the influence of ultraconservative endodontic cavities (UEC) on canal shaping and filling ability, cleaning of the pulp chamber, time required to perform root canal treatment and fracture resistance of 2-rooted maxillary premolars in comparison with traditional endodontic access cavities (TEC) in extracted teeth placed in a phantom head to simulate clinical conditions. METHODOLOGY: Twenty extracted intact 2-rooted maxillary premolars were scanned in a micro-computed tomographic device, matched based on similar anatomical features of the canals and assigned to UEC or TEC groups (n = 10). Then, teeth were mounted on a mannequin head and their pulp chamber accessed. After canal preparation, filling and cavity restoration, the time required to perform root canal treatment was recorded and the specimens were loaded to fracture in a universal testing machine. The maximum load at fracture was recorded. The sample was scanned after root canal instrumentation, filling and restoration procedures. Untouched canal areas, accumulation of hard-tissue debris (AHTD), voids in root fillings and cleaning of the pulp chamber were analysed. Data were analysed statistically using Shapiro-Wilk and Student's t-tests with a significance level of 5%. RESULTS: The percentage of untouched canal area did not differ significantly between UEC and TEC groups (P > 0.05). However, UECs were associated with a greater percentage of AHTD after canal preparation (P < 0.05). No differences were observed in terms of voids in root fillings between the groups (P > 0.05). Nonetheless, UEC had a greater percentage of root filling remnants in the pulp chamber after cleaning procedures (P < 0.05). The time required to perform root canal treatment was significantly longer in the UEC group (P < 0.05). There was no difference regarding the mean load at fracture between the groups (P > 0.05). Unrestorable fractures were observed in all specimens of both groups. CONCLUSIONS: There was no true benefit associated with ultraconservative endodontic cavities. UEC resulted in more AHTD remaining inside the root canals. UEC did not influence the quality of root fillings; however, UEC made the cleaning procedure of the pulp chamber more difficult, thus increasing the total time required to perform root canal treatment. Moreover, UEC were not associated with an increase in fracture resistance of root filled 2-rooted maxillary premolars.


Asunto(s)
Cavidad Pulpar , Materiales de Obturación del Conducto Radicular , Diente Premolar , Humanos , Preparación del Conducto Radicular , Tratamiento del Conducto Radicular
7.
Int Endod J ; 53(11): 1506-1515, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32780440

RESUMEN

AIM: To investigate a potential cause-effect relationship between dentinal microcracks and fracture resistance of mandibular incisors that had not been endodontically treated. METHODOLOGY: Sixty mandibular incisors with circular-shaped canals were selected based on micro-computed tomographic scans to create a homogeneous sample. The cross-sectional images of the specimens were screened to identify and quantify the presence of dentinal microcracks. Then, teeth were embedded in polystyrene resin and subjected to axial compressive loading using a universal testing machine. After fracture, the roots were re-scanned and fractography analysis was performed by inspection of 3D models to verify crack propagation. Spearman's rank correlation was used to assess the correlation between the number of microcracks and force required to fracture. RESULTS: Dentinal microcracks were detected in 79% of the specimens (n = 44). The incidence of microcracks varied between teeth from 6% to 42% of the total slices per sample (average of 14 ± 17%). The number of microcracks per sample varied from 0 to 1605, with an average of 412 ± 484 (median = 221 and IQR 25% = 15/75% = 658). The load at failure values varied from 227 to 924 N, with an average of 560.3 ± 168.1 N (median = 561 and IQR 25% = 458/75% = 694). The Spearman correlation coefficient (rho) equalled 0.065. CONCLUSIONS: There was no cause-effect relationship between the number of dentinal microcracks and the fracture resistance of nonendodontically treated mandibular incisors. The presence and quantity of microcracks did not make these roots more prone to fracture.


Asunto(s)
Preparación del Conducto Radicular , Fracturas de los Dientes , Estudios Transversales , Dentina , Humanos , Laboratorios , Rol , Fracturas de los Dientes/diagnóstico por imagen , Fracturas de los Dientes/etiología , Microtomografía por Rayos X
8.
Int Endod J ; 53(12): 1680-1688, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32767779

RESUMEN

AIM: To evaluate the use of a reduced taper endodontic instrument system (Bassi Logic™ .03 taper) and expandable heat-treated system (XP-endo Shaper) on the ability to shape canals in mandibular molars, by means of microcomputed tomography (micro-CT) analysis. The Reciproc system was used as the reference for comparison. METHODOLOGY: Twenty-four mandibular molars were scanned in a micro-CT, matched based on similar anatomical features and sorted into three groups (n = 8 per group), according to root canal preparation system: Bassi Logic™ .03, XP-endo Shaper and Reciproc. The teeth were mounted onto a mannequin and the pulp chambers were accessed with traditional access cavities. In Bassi Logic™ .03 and Reciproc groups, mesial canals were prepared with size 25, .03 taper or R25 (size 25, .08v taper) instruments and the distal root canal with size 25, .03 taper and size 40, .03 taper or R25 and R40 (size 40, .06v taper), respectively. In XP-endo Shaper groups, all root canals were prepared with XP-endo Shaper (size 30, .04v taper). After root canal preparation, the teeth were rescanned. The percentage of untouched canal areas and the percentage of removed dentine were evaluated separately for mesial and distal root canals. The data were analysed using one-way anova and Tukey tests (P < 0.05). RESULTS: The Bassi Logic™ .03 group was associated with a greater percentage of untouched canal areas when compared to XP-endo Shaper and Reciproc groups for mesial and distal root canals (P < 0.05), but no differences were found between XP-endo Shaper and Reciproc groups (P > 0.05). No significant difference was observed in the percentage of dentine removed amongst the groups for mesial and distal root canals (P > 0.05). CONCLUSION: The use of a reduced taper system (Bassi Logic™ .03) during root canal preparation resulted in a greater percentage of untouched canal areas when compared to XP-endo Shaper and Reciproc instruments. No differences were observed amongst the systems regarding the percentage of dentine removed.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Movimiento Celular , Cavidad Pulpar/diagnóstico por imagen , Diente Molar/diagnóstico por imagen , Diente Molar/cirugía , Microtomografía por Rayos X
9.
Int Endod J ; 53(4): 440-446, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31622501

RESUMEN

AIM: To evaluate the incidence of root dentinal microcracks after two extraction techniques through micro-computed tomographic (micro-CT) analysis. METHODOLOGY: Thirty pairs of premolars, extracted for orthodontic reasons, were assigned to two experimental groups, following a split-mouth design (n = 30): traumatic technique group (TTG) - teeth extracted following a conventional protocol using forceps, and an atraumatic technique group (ATG) - teeth extracted following an atraumatic technique protocol in which the root was gently detached from the periodontal ligament using a periotome. All teeth were immediately immersed in distilled water and scanned in a micro-CT device within 72 h following the extraction. The assessment of the images was completed on cross-section images by two masked evaluators. The Mann-Whitney test was used to assess the significant differences between the groups regarding the number of cross-sections displaying microcracks whilst the Fischer's exact test was used to assess differences in the frequency of specimens with defects (P < 0.05). RESULTS: A total of 52 750 micro-CT cross-sectional images were evaluated. A total of 352 cross-sections had at least one dentinal defect. Microcracks were observed in five teeth of the TTG group (n = 352 slices) and in two teeth of the ATG group (n = 103 slices). The statistical analysis used was unable to detect a significant difference between the groups in terms of the number of dentinal microcracks (P = 0.233) and in the frequency of teeth displaying microcracks (P = 0.424). CONCLUSION: A small number of sound teeth without endodontic treatment had dentinal microcracks regardless of the extraction technique applied. No difference was noticed between the traumatic and atraumatic techniques in the incidence of microcracks.


Asunto(s)
Preparación del Conducto Radicular , Fracturas de los Dientes , Estudios Transversales , Dentina , Humanos , Microtomografía por Rayos X
10.
Int Endod J ; 52(6): 899-907, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30663790

RESUMEN

AIM: To evaluate the performance of XP-endo Finisher R instruments when removing root filling remnants from oval-shaped canals using microcomputed tomographic (micro-CT) imaging as the analytical tool. Passive ultrasonic irrigation (PUI) was used as a reference technique for comparison. METHODOLOGY: Twenty mandibular incisors with oval-shaped canals were matched based on similar anatomic features of the canal (volume, aspect ratio and 3D configuration) after scanning procedures. The canals were prepared with Reciproc R25 instruments, filled with gutta-percha and AH Plus sealer using the single-cone technique and retreated up to a Reciproc R40 instrument. After retreatment procedures, the specimens were rescanned, and the homogeneity between the specimens, the oval-shaped anatomy and the remaining filling material were confirmed. The pair-matched samples were assigned to two experimental groups (n = 10), according to the supplementary approach used: XP-endo Finisher R or PUI. Each sample was scanned after each endodontic procedure. The volume of remaining root filling material was quantified before and after the use of each supplementary approach. This analysis was performed considering the total canal (Student t-test) and also by thirds (anova procedure followed by a Bonferroni correction). Data were analysed statistically with a significance level of 5%. RESULTS: The volume of root filling material at baseline was similar between the groups (t-test, P = 0.787). XP-endo Finisher R removed significantly more root filling material compared to PUI (t-test, P = 0.015), as it removed a mean of ≅32% material compared to 12% for the PUI. There was no difference in the amount of root filling material removed in the root canal thirds after using both supplementary approaches (one-way anova, P = 0.07 for XP-endo Finisher R and P = 0.886 for PUI). CONCLUSIONS: Both supplementary approaches significantly reduced the volume of remaining root filling material from oval-shaped canals. The XP-endo Finisher R instrument removed significantly more root filling material than PUI. None of the supplementary approaches was able to render oval-shaped canals completely free from remaining root filling material.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Obturación del Conducto Radicular , Cavidad Pulpar , Gutapercha , Humanos , Retratamiento , Preparación del Conducto Radicular , Microtomografía por Rayos X
11.
Int Endod J ; 52(6): 857-865, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30549297

RESUMEN

AIM: To investigate the prevalence, location and pattern of pre-existing microcracks in non-endodontically treated teeth from fresh cadavers. Micro-computed tomography (micro-CT) technology was used as the analytical tool enabling full screening of the root dentine with the teeth retained in their original alveolar socket. METHODOLOGY: As a pilot study and to validate the present method, a series of 4 high-resolution scans were performed on one bone-block specimen with teeth collected post-mortem: (i) entire bone-block including the teeth, (ii) second molar tooth extracted atraumatically from the bone-block, (iii) extracted tooth dehydrated to induce dentinal defects and (iv) entire bone-block following reinsertion of the extracted tooth into its matching alveolar socket. In the main study, forty-two dentoalveolar maxillary and mandibular bone-blocks each containing 3-5 adjacent teeth (a total of 178 teeth) were collected post-mortem and scanned in a micro-CT device. All cross-section images of the 178 teeth (n = 65 530) were screened from the cementoenamel junction to the apex to identify the presence of dentinal defects. RESULTS: In the pilot study, the microcracks observable when the dehydrated tooth was outside the bone-block remained detectable when the entire bone-block plus reinserted tooth was scanned. This means that the screening process revealed the presence of the same microcracks in both experimental situations (the tooth outside and inside the maxillary bone-block). From a total of 178 teeth in the bone-blocks removed from cadavers, 65 530 cross-sectional images were analysed and no dentinal microcracks were detected. CONCLUSIONS: This in situ cadaveric model revealed the lack of pre-existing dentinal microcracks in non-endodontically treated teeth. Thus, the finding of dentinal microcracks observed in previous cross-sectional images of stored extracted teeth is unsound and not valid. It should be assumed that microcracks observed in stored extracted teeth subjected to root canal procedures are a result of the extraction process and/or the post-extraction storage conditions. Therefore, as a consequence, the presence of such dentinal microcracks in stored extracted teeth - observable in cross-sectional images of the roots - should be referred to as experimental dentinal microcracks.


Asunto(s)
Preparación del Conducto Radicular , Raíz del Diente , Estudios Transversales , Dentina , Humanos , Proyectos Piloto , Microtomografía por Rayos X
12.
Int Endod J ; 52(3): 337-342, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30118136

RESUMEN

AIM: To assess the shaping ability of the new XP-endo Shaper instrument after different working times. METHODOLOGY: Ten mesial roots of mandibular molars were scanned in a micro-computed tomographic device and prepared using the XP-endo Shaper instrument up to the working length (WL) according to the manufacturer's recommendation. Then, each specimen was subjected to an extra 15, 30 and 45 s of active instrumentation at the WL. Postoperative scans were performed after canal preparation at each time-point. Then, the registered pre- and postoperative datasets were examined to evaluate the percentages of volume and surface area of the instrumented canal, surface area of noninstrumented canal areas and the volume of removed dentine. Repeated measures general linear model was used to compare the differences in either the increase or the reduction of the parameters amongst the time-points. Alpha-error was set at 5%. RESULTS: Extending the period of XP-endo Shaper active instrumentation at WL significantly influenced several parameters such as volume (P < 0.001) and surface area (P < 0.001) of the instrumented canal, surface area of noninstrumented canal areas (P < 0.001), and volume of removed dentine (P < 0.001). CONCLUSIONS: Extending the activation time of XP-endo Shaper instruments at WL resulted in a more comprehensive root canal preparation, increasing the volume and surface area of root canal preparation and the volume of removed dentine.


Asunto(s)
Instrumentos Dentales , Diente Molar/cirugía , Preparación del Conducto Radicular/instrumentación , Diseño de Equipo , Humanos , Técnicas In Vitro , Diente Molar/diagnóstico por imagen , Microtomografía por Rayos X
13.
Int Endod J ; 52(10): 1501-1507, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31066080

RESUMEN

AIM: To investigate the smallest dentine thickness in mesial canals of mandibular molars along the cervical and middle thirds of the root by means of a micro-computed tomographic (micro-CT) technology and digital image analysis. METHODOLOGY: Fifty mesial roots of mandibular molars having two independent canals (mesiobuccal and mesiolingual), in the coronal and middle levels, were selected and scanned in a micro-CT device. After reconstruction procedures, approximately 468 slices per root covering the 7 mm below the furcation area of the mesial root were analysed to measure the smallest dentine thickness (danger zone [DZ]) in each slice from both distal and mesial regions of the mesial canals by an automatic segmentation process. RESULTS: The DZ values in the mesiobuccal canals varied from 0.67 to 1.93 mm, with an average of 1.13 ± 0.21 mm. For the mesiolingual canals, the DZ varied from 0.77 to 1.89 mm with an average of 1.10 ± 0.21 mm. There was no correspondence in the DZ between the mesiobuccal and mesiolingual canals at the same cross-sectional level in 71% of the specimens. Moreover, the smallest dentine thickness was towards the mesial region of the roots in 22% and 18% of the mesiolingual and mesiobuccal canals, respectively. (Figs 1 and 2 CONCLUSIONS: The smallest dentine thickness was on the mesial plane of the roots in about 40% of the canals. The vertical location of the DZ in relation to the furcation area was in the middle third of the root.


Asunto(s)
Mandíbula , Diente Molar , Estudios Transversales , Cavidad Pulpar , Dentina , Raíz del Diente , Microtomografía por Rayos X
14.
Int Endod J ; 51(11): 1292-1300, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29682752

RESUMEN

AIM: To test the hypothesis that polyacrylic acid-based and calcium silicate materials are able to increase mineral density of artificially demineralized dentine produced by a microcosm model for caries formation. METHODOLOGY: Forty-five dentine cavities were prepared in nine sound human third molars (five in each tooth). Specimens received a bacterial inoculum and were incubated in BHI plus 5% of sucrose for 96 h to allow biofilm formation. After that, the specimens were scanned in a high energy micro-CT (baseline stack) and then, each cavity was filled with different cements: zinc polycarboxylate (Poly Zinc™, Prevest DenPro, Jammu, India), conventional glass-ionomer (Ketac Molar, 3M ESPE, Seefeld, Germany) and two calcium silicate-based materials (MTA, Angelus, Londrina, Brazil and Biodentine™, Septodont, Saint Maur des Fosses, France) whilst the central cavity was filled with utility wax (negative control). Specimens were kept for 45 days under simulated intrapulpal pressure using simulated body fluid and after, they were again scanned (treated stacks). Reconstruction of the acquired projections was accomplished using standardized parameters, and the percentage mineral density change was calculated around each cavity. Data were tested for normality using the Shapiro-Wilk test, followed by nonparametric methods. RESULTS: A microcosm artificial caries model was able to cause dentine demineralization (±90% related to sound dentine). Significant increases in dentine mineral density were achieved using MTA or Poly Zinc™ (43.56% and 41.64% remineralization), followed by Biodentine™ (36.40%) and Ketac Molar (32.54%), P < 0.05. CONCLUSION: All cements increased mineral density in demineralized dentine, but zinc polycarboxylate cement and MTA had greater bioactive potential. Micro-CT proved to be an effective method to evaluate changes in mineral density within dentine in contact with bioactive materials.


Asunto(s)
Resinas Acrílicas/farmacología , Compuestos de Calcio/farmacología , Caries Dental/tratamiento farmacológico , Caries Dental/metabolismo , Cementos Dentales/farmacología , Minerales/química , Silicatos/farmacología , Adolescente , Biopelículas/crecimiento & desarrollo , Niño , Caries Dental/diagnóstico por imagen , Caries Dental/microbiología , Dentina , Cementos de Ionómero Vítreo , Humanos , Ensayo de Materiales , Tercer Molar/efectos de los fármacos , Cemento de Policarboxilato , Desmineralización Dental
15.
Int Endod J ; 51(5): 564-571, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-28667674

RESUMEN

AIM: To compare the shaping ability of four root canal instrumentation systems in oval-shaped canals using micro-computed tomographic analysis. METHODOLOGY: Forty anatomically matched mandibular incisors were scanned and assigned to four groups (n = 10), according to the canal preparation protocol: BioRace, Reciproc, Self-Adjusting File (SAF) and TRUShape systems. After canal instrumentation, the specimens were rescanned, and the registered pre- and postoperative datasets were examined to evaluate the percentages of accumulated hard-tissue debris, untouched canal walls and dentine removed. Kruskal-Wallis and Mann-Whitney U-tests with Bonferroni correction were used to compare the variables in the groups (α = 5%). RESULTS: The preparation techniques did not affect the percentage of accumulated hard-tissue debris (P = 0.126). The percentage of untouched canal areas was significantly higher for BioRace (32.38%)compared to Reciproc (18.95%) and SAF (16.08%) systems (P < 0.05). Reciproc removed significantly more dentine (4.18%) than BioRace (2.21%) and SAF (2.56%) (P < 0.05). The TRUShape system had intermediate results for both untouched canal walls (19.20%) and dentine removed (3.77%), with no significant difference compared to BioRace, Reciproc and SAF systems. CONCLUSIONS: The preparation techniques resulted in the same level of accumulated hard-tissue debris. Compared to the other tested systems, BioRace was associated with more untouched canal walls and Reciproc produced the greatest amount of removed dentine. Although it touched more of the root canal walls, the SAF system removed less dentine, whereas TRUShape had intermediate results for these same parameters. None of the systems tested were able to provide optimal shaping ability in oval-shaped canals.


Asunto(s)
Cavidad Pulpar/cirugía , Obturación del Conducto Radicular/instrumentación , Cavidad Pulpar/anatomía & histología , Cavidad Pulpar/diagnóstico por imagen , Humanos , Incisivo/anatomía & histología , Incisivo/cirugía , Maxilar , Microtomografía por Rayos X
16.
J Fish Dis ; 40(12): 1869-1881, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28707706

RESUMEN

Zooarchaeological collections from shell mounds in Rio de Janeiro (2,470-4,632 cal BP) contain a high prevalence of swollen fish bones belonging to the Atlantic spadefish (Chaetodipterus faber), crevalle jack (Caranx hippos) and fat snook (Centropomus parallelus). Given the lack of knowledge of the bone degenerative process in senile fishes, this study analysed hyperostotic bone in zooarchaeological and modern specimens to obtain high-resolution morphology and microstructure reconstruction. We used microCT as well as X-ray diffraction to characterize the crystallographic changes associated with fish senility. Our results showed that trabecular microstructures in hyperostotic bones were consistent with estimated values of the per cent bone volume-to-total volume ratio (BV/TV) and were greater than 60% in cortical bone. Hyperostotic bones indicated a high radiograph density, and X-ray diffractograms showed a decrease in hydroxyapatite [Ca10 (PO4 )6 (OH)2 ] and calcite (CaCO3 ) neocrystallization. These crystalline and density changes revealed an advanced stage of fish senile and indicate the vulnerability of ageing fish populations.


Asunto(s)
Huesos/anatomía & histología , Peces/anatomía & histología , Envejecimiento , Animales , Arqueología , Huesos/ultraestructura , Brasil , Carbonato de Calcio/química , Durapatita/química , Historia Antigua , Difracción de Rayos X , Microtomografía por Rayos X
17.
Int Endod J ; 50(9): 895-901, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27689844

RESUMEN

AIM: To evaluate the frequency of dentinal micro-cracks after root canal filling procedures with GuttaCore (GC), cold lateral compaction (CLC) and warm vertical compaction (WVC) techniques in mandibular molars using micro-computed tomographic analysis. METHODOLOGY: Thirty mesial roots of mandibular molars, with a type II Vertucci's canal configuration, were prepared to working length with a Reciproc R40 instrument and randomly assigned to one of the three experimental groups (n = 10), according to the technique used for root filling: GC, CLC or WVC. The GC group was filled with a size 40 GC obturator, whilst CLC and WVC groups used conventional gutta-percha cones. AH Plus sealer was used in all groups. The specimens were scanned at an isotropic resolution of 14.25 µm before and after root canal preparation and after root filling. Then, all pre- and postoperative cross-sectional images of the roots (n = 41 660) were screened to identify the presence of dentinal defects. RESULTS: Overall, 30.75% (n = 12 810) of the pre- + post-filling images displayed dentinal defects. In the GC, CLC and WVC groups, dentinal micro-cracks were observed in 18.68% (n = 2510), 15.99% (n = 2389) and 11.34% (n = 1506) of the cross-sectional images, respectively. All micro-cracks identified in the post-filling scans were also observed in the corresponding post-preparation images. CONCLUSION: Root fillings in all techniques did not induce the development of new dentinal micro-cracks.


Asunto(s)
Dentina/lesiones , Complicaciones Posoperatorias/diagnóstico por imagen , Obturación del Conducto Radicular/efectos adversos , Raíz del Diente/lesiones , Microtomografía por Rayos X , Dentina/diagnóstico por imagen , Gutapercha , Humanos , Mandíbula , Diente Molar , Materiales de Obturación del Conducto Radicular , Raíz del Diente/diagnóstico por imagen
18.
Int Endod J ; 48(11): 1033-42, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25353648

RESUMEN

AIM: To propose an automated image processing routine based on free software to quantify root canal preparation outcomes in pairs of sound and instrumented roots after micro-CT scanning procedures. METHODOLOGY: Seven mesial roots of human mandibular molars with different canal configuration systems were studied: (i) Vertucci's type 1, (ii) Vertucci's type 2, (iii) two individual canals, (iv) Vertucci's type 6, canals (v) with and (vi) without debris, and (vii) canal with visible pulp calcification. All teeth were instrumented with the BioRaCe system and scanned in a Skyscan 1173 micro-CT before and after canal preparation. After reconstruction, the instrumented stack of images (IS) was registered against the preoperative sound stack of images (SS). Image processing included contrast equalization and noise filtering. Sound canal volumes were obtained by a minimum threshold. For the IS, a fixed conservative threshold was chosen as the best compromise between instrumented canal and dentine whilst avoiding debris, resulting in instrumented canal plus empty spaces. Arithmetic and logical operations between sound and instrumented stacks were used to identify debris. Noninstrumented dentine was calculated using a minimum threshold in the IS and subtracting from the SS and total debris. Removed dentine volume was obtained by subtracting SS from IS. RESULTS: Quantitative data on total debris present in the root canal space after instrumentation, noninstrumented areas and removed dentine volume were obtained for each test case, as well as three-dimensional volume renderings. CONCLUSION: After standardization of acquisition, reconstruction and image processing micro-CT images, a quantitative approach for calculation of root canal biomechanical outcomes was achieved using free software.


Asunto(s)
Diente Molar/diagnóstico por imagen , Diente Molar/cirugía , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Preparación del Conducto Radicular/métodos , Programas Informáticos , Microtomografía por Rayos X , Algoritmos , Humanos , Mandíbula
20.
Horm Metab Res ; 46(4): 259-68, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24627101

RESUMEN

Childhood obesity is growing in prevalence. Obesity and bone dysfunctions may be related disorders, and therefore our aim was to study the impact of the early overfeeding (EO) in offspring bone health since weaning up to adulthood. To induce EO during lactation, litter size was adjusted to 3 male rats per litter (SL). Litter containing 10 pups per mother was the control (NL). Bone tissue was evaluated by dual-energy X-ray absorptiometry, computed tomography, microcomputed tomography, biomechanical tests, and serum analyses. SL offspring presented higher body weight, fat mass, lean mass from 21 up to 180 days, hyperphagia, and higher visceral fat mass. Bone analysis showed that SL offspring presented higher total bone mineral density (BMD) only at 180 days, and higher total bone mineral content and higher bone area from 21 until 180 days. At 180 days, SL offspring presented higher femur BMD and fourth lumbar vertebra (LV4) BMD, higher femoral head radiodensity and LV4 vertebral body radiodensity, lower trabecular pattern factor and trabecular separation, however with higher trabecular number, higher maximal load, resilience, stiffness and break load, and lower break deformation. SL group had, at 180 days, higher osteocalcin and lower C-terminal cross-linked telopeptide of type I collagen (CTX I). We have shown that the excess of fat mass contributed to an increased bone mass, and hypothesized that this increase could be mediated by the hypothyroidism and previous higher thyroid hormone action and hyperleptinemia at weaning. Furthermore, the increased biomechanical loading due to increased body weight probably help us to understand the protective effects obesity exerts upon bone health.


Asunto(s)
Conducta Alimentaria , Fémur/patología , Fémur/fisiopatología , Hipernutrición/patología , Hipernutrición/fisiopatología , Absorciometría de Fotón , Animales , Animales Recién Nacidos , Fenómenos Biomecánicos , Peso Corporal , Densidad Ósea , Colágeno Tipo I/metabolismo , Femenino , Fémur/diagnóstico por imagen , Grasa Intraabdominal/fisiopatología , Masculino , Tamaño de los Órganos , Osteocalcina/metabolismo , Hipernutrición/diagnóstico por imagen , Péptidos/metabolismo , Ratas Wistar , Destete , Soporte de Peso , Microtomografía por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA