Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Europace ; 20(5): 772-777, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-29741689

RESUMEN

Aims: The efficacy of the second-generation cryoballoon (CB) ablation in patients with atrial fibrillation (AF) has been demonstrated previously. Data on the efficacy of CB ablation in elderly patients is missing. The aim of this study was to evaluate the long-term success rate of pulmonary vein isolation (PVI) in patients ≥75 years vs. <75 years using the second-generation 28mm CB. Methods and results: Eighty patients [n = 40 ≥75 years (Group 1); n = 40 <75 years (Group 2)] with paroxysmal [n = 37 (46%) or persistent (n = 43 (54%)] AF were included. Median follow-up was 12 [6;18] months (Group 1 vs. 13 [6;27]) months (Group 2; P = 0.8). PVI was performed in all patients using cryoablation. Follow-up was obtained using 24h-Holter monitoring or via an implanted loop recorder or pacemaker. CHA2DS2VASc-Score (Group 1: 4 [4;5] vs. Group 2: 2 [1;3], P < 0.001) and HASBLED-Score (Group 1: 2 [2;3] and Group 2: 2 [1;3], (P = 0.009)) differed significantly between the two groups. Mean fluoroscopy time was 22.9 [16.3;31.9] in Group 1 and 24.5 [19.1;30.6] in Group 2 (P = 0.75), and mean procedure time was 125 min [105;151] in Group 1 and 130.5 min [117.5;147.3] in Group 2 (P = 0.66). Arrhythmia recurrence was similar in Group 1 and Group 2 (12/40 (30%) vs. 10/40 (25%) (P = 0.62). One transient ischaemic attack occurred in Group 2. No further major complications were documented in this patients cohort. Conclusion: CB ablation in patients ≥75 years has favourable success rates and similar complication rates compared with patients <75 years.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Criocirugía , Efectos Adversos a Largo Plazo , Factores de Edad , Anciano , Fibrilación Atrial/diagnóstico , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Electrocardiografía Ambulatoria/métodos , Femenino , Estudios de Seguimiento , Humanos , Efectos Adversos a Largo Plazo/diagnóstico , Efectos Adversos a Largo Plazo/etiología , Masculino , Persona de Mediana Edad , Recurrencia , Resultado del Tratamiento
2.
Clin Cardiol ; 40(11): 1095-1099, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28846806

RESUMEN

BACKGROUND: Data are limited on the safety of periprocedural anticoagulation with novel oral anticoagulants (NOACs) in patients undergoing pulmonary vein isolation (PVI) using the second-generation cryoballoon (CB) for the treatment of atrial fibrillation. HYPOTHESIS: We hypothesized that the incidence of acute periprocedural complications in patients undergoing PVI do not differ between patients treated with VKA compared to NOACs. METHODS: In 200 consecutive patients (mean age, 64.3 _ 10.6 years; female, n = 83) with symptomatic atrial fibrillation, PVI using the second-generation 28-mm CB was performed. In patients treated with NOACs, the medication was stopped the day of the procedure and continued the evening after the procedure with a reduced dosage. Patients treated with phenprocoumon were continued on uninterrupted phenprocoumon with a target INR of 2 to 3. If INR was <2, bridging with low-molecular-weight heparin was performed. RESULTS: Forty-seven of 200 patients (23.5%) were treated with a vitamin K antagonist (VKA) and 55 (27.5%) were treated with apixaban, 67 (33.5%) with rivaroxaban, and 31 (15.5%) with dabigatran. Seven (3.5%) major complications occurred in the overall population. Major bleeding complications did not differ significantly between the 2 groups (P = 0.23). One patient taking VKA had a pericardial tamponade at the end of the procedure; 2 patients treated with apixaban developed a groin hematoma requiring surgical intervention. Transient ischemic attack occurred in 1 patient of the apixaban and rivaroxaban group. CONCLUSIONS: Apixaban, rivaroxaban, and dabigatran, compared with uninterrupted VKA, did not show a higher risk for major bleeding or ischemic complications in patients undergoing PVI using the second-generation CB.


Asunto(s)
Antitrombinas/administración & dosificación , Fibrilación Atrial/terapia , Catéteres Cardíacos , Criocirugía/instrumentación , Dabigatrán/administración & dosificación , Inhibidores del Factor Xa/administración & dosificación , Pirazoles/administración & dosificación , Piridonas/administración & dosificación , Rivaroxabán/administración & dosificación , Administración Oral , Anciano , Antitrombinas/efectos adversos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Trastornos Cerebrovasculares/etiología , Criocirugía/efectos adversos , Dabigatrán/efectos adversos , Esquema de Medicación , Monitoreo de Drogas/métodos , Diseño de Equipo , Inhibidores del Factor Xa/efectos adversos , Femenino , Heparina de Bajo-Peso-Molecular/administración & dosificación , Humanos , Relación Normalizada Internacional , Masculino , Persona de Mediana Edad , Fenprocumón/administración & dosificación , Hemorragia Posoperatoria/inducido químicamente , Pirazoles/efectos adversos , Piridonas/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Rivaroxabán/efectos adversos , Factores de Tiempo , Resultado del Tratamiento , Vitamina K/antagonistas & inhibidores
3.
Heart Rhythm ; 13(9): 1817-22, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27241353

RESUMEN

BACKGROUND: The efficacy of the second-generation cryoballoon (CB) in patients with paroxysmal atrial fibrillation (AF) has been demonstrated previously. Data on the efficacy of CB ablation in patients with persistent AF are sparse. OBJECTIVE: The aim of this study was to evaluate the 2-year success rate of pulmonary vein isolation in patients with persistent AF using the second-generation CB. METHODS: Fifty consecutive patients (mean age 64.6 ± 9.9 years; 19 women [38%]) with persistent AF were included in this analysis. The mean follow-up period was 22 ± 11 months. All patients were ablated using the second-generation 28-mm CB. Isolation of the pulmonary veins was confirmed using a spiral mapping catheter. In all patients, follow-up was obtained using 24-hour Holter monitoring or via interrogation of an implanted loop recorder or pacemaker. RESULTS: The mean left atrial diameter was 43.6 ± 5.6 mm, the mean CHA2DS2-VASc score was 2.8 ± 1.5, and the mean HAS-BLED score was 2.1 ± 1.2. The mean fluoroscopy time was 25.8 ± 9 minutes, and the mean procedural time was 146.4 ± 37.8 minutes. After 22 ± 11 months, the frequency of arrhythmia recurrence was 22 of 50 (44%) in the overall group (paroxysmal AF 6 of 22 [27%]; persistent AF 16 of 22 [73%]). No major complications occurred. Aneurysma spurium not requiring surgical intervention occurred in 1 (2%) patient. No phrenic nerve palsy was observed. CONCLUSION: Two years' results after pulmonary vein isolation using the second-generation CB in patients with persistent AF are promising. The clinical success rate appears to be similar to the reported success rates of radiofrequency ablation for the treatment of persistent AF.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía , Venas Pulmonares/cirugía , Anciano , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Insuficiencia del Tratamiento , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA