1.
Clin Diabetes ; 40(2): 168-184, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35669307

RESUMEN

Automated insulin delivery (AID) systems, which connect an insulin pump, continuous glucose monitoring system, and software algorithm to automate insulin delivery based on real-time glycemic data, hold promise for improving outcomes and reducing therapeutic burden for people with diabetes. This article reviews the features of the Omnipod 5 Automated Insulin Delivery System and how it compares to other AID systems available on or currently under review for the U.S. market. It also provides practical guidance for clinicians on how to effectively train and onboard people with diabetes on the Omnipod 5 System, including how to personalize therapy and optimize glycemia. Many people with diabetes receive their diabetes care in primary care settings rather than in a diabetes specialty clinic. Therefore, it is important that primary care providers have access to resources to support the adoption of AID technologies such as the Omnipod 5 System.

2.
Clin Diabetes ; 39(1): 72-79, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33551556

RESUMEN

Continuous subcutaneous insulin infusion (CSII) treatment may improve long-term glycemic outcomes and enhance quality of life compared with a multiple daily injection (MDI) insulin regimen for people with type 1 diabetes. As the number of people treated with CSII via a tubeless insulin pump is increasing, there is growing interest in the long-term glycemic outcomes of this treatment option across diverse populations. This multicenter, retrospective study evaluated glycemic control in 156 adults with type 1 diabetes initiating tubeless insulin pump therapy following transition from either MDI or CSII with a tubed insulin pump. In this study, use of the tubeless insulin pump over 12 months was associated with significant improvement in A1C in adults with type 1 diabetes, most notably in those with an A1C ≥9.0% and those previously treated with MDI.

3.
Pediatr Diabetes ; 19(3): 420-428, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29159870

RESUMEN

OBJECTIVE: The primary objective of this trial was to evaluate the feasibility, safety, and efficacy of a predictive hyperglycemia and hypoglycemia minimization (PHHM) system vs predictive low glucose suspension (PLGS) alone in optimizing overnight glucose control in children 6 to 14 years old. RESEARCH DESIGN AND METHODS: Twenty-eight participants 6 to 14 years old with T1D duration ≥1 year with daily insulin therapy ≥12 months and on insulin pump therapy for ≥6 months were randomized per night into PHHM mode or PLGS-only mode for 42 nights. The primary outcome was percentage of time in sensor-measured range 70 to 180 mg/dL in the overnight period. RESULTS: The addition of automated insulin delivery with PHHM increased time in target range (70-180 mg/dL) from 66 ± 11% during PLGS nights to 76 ± 9% during PHHM nights (P<.001), without increasing hypoglycemia as measured by time below various thresholds. Average morning blood glucose improved from 176 ± 28 mg/dL following PLGS nights to 154 ± 19 mg/dL following PHHM nights (P<.001). CONCLUSIONS: The PHHM system was effective in optimizing overnight glycemic control, significantly increasing time in range, lowering mean glucose, and decreasing glycemic variability compared to PLGS alone in children 6 to 14 years old.


Asunto(s)
Diabetes Mellitus Tipo 1/sangre , Hiperglucemia/prevención & control , Hipoglucemia/prevención & control , Sistemas de Infusión de Insulina , Monitoreo Ambulatorio/instrumentación , Adolescente , Glucemia , Niño , Alarmas Clínicas , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Método Doble Ciego , Estudios de Factibilidad , Femenino , Humanos , Masculino
4.
Pediatr Diabetes ; 18(5): 332-339, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-27125223

RESUMEN

Overnight predictive low glucose suspend (PLGS) reduces hypoglycemia across all ages; however, there are no reports on behavior or experience differences across age groups, especially in pediatrics. As run-in for a subsequent randomized clinical trial (RCT), 127 subjects (50% male) ages 4-45 yr utilized the experimental PLGS system nightly for 5-10 nights (PLGS active phase). We analyzed the number of blood glucose (BG) checks and boluses given per age group. During the subsequent 42 night RCT phase, we analyzed sensor use, skin reactions, errors, and reasons why the experimental system was not used. In 821 nights of active PLGS, subjects ages 4-6 yr (and their parents) tested BG levels 75% of nights compared with 65% of nights (7-10 yr), 53% of nights (11-14 yr), 33% of nights (15-25 yr), and 28% of nights (26-45 yr), respectively (p < 0.001). Likewise, youngest subjects (and parents) administered insulin boluses 56% of nights during active PLGS use compared with 48%, 33%, 20%, and 25%, respectively (p < 0.001). This was unrelated to study requirements. During the RCT phase, subjects 4-6 yr experienced more frequent and severe skin reactions (p = 0.02), while adult subjects (26-45 yr) wore individual sensors a median of 26 h longer than the youngest subjects (p < 0.001). Technical problems with the sensor (errors, miscalibrations, etc.), traveling, and BG levels >270 at bedtime (study requirement) were primary contributors to non-system use. Understanding the different use patterns and challenges in pediatrics and adolescence is needed to direct patient education to optimize use of PLGS and future artificial pancreas systems.


Asunto(s)
Glucemia/análisis , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemia/etiología , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Páncreas Artificial/efectos adversos , Cooperación del Paciente , Adolescente , Adulto , Factores de Edad , Algoritmos , Niño , Preescolar , Estudios de Cohortes , Diabetes Mellitus Tipo 1/sangre , Femenino , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemiantes/efectos adversos , Hipoglucemiantes/uso terapéutico , Insulina/efectos adversos , Insulina/uso terapéutico , Masculino , Persona de Mediana Edad , Padres , Sueño , Interfaz Usuario-Computador , Adulto Joven
5.
Pediatr Diabetes ; 18(5): 348-355, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-27191182

RESUMEN

BACKGROUND: Automated insulin delivery systems, utilizing a control algorithm to dose insulin based upon subcutaneous continuous glucose sensor values and insulin pump therapy, will soon be available for commercial use. The objective of this study was to determine the preliminary safety and efficacy of initialization parameters with the Medtronic hybrid closed-loop controller by comparing percentage of time in range, 70-180 mg/dL (3.9-10 mmol/L), mean glucose values, as well as percentage of time above and below target range between sensor-augmented pump therapy and hybrid closed-loop, in adults and adolescents with type 1 diabetes. METHODS: We studied an initial cohort of 9 adults followed by a second cohort of 15 adolescents, using the Medtronic hybrid closed-loop system with the proportional-integral-derivative with insulin feed-back (PID-IFB) algorithm. Hybrid closed-loop was tested in supervised hotel-based studies over 4-5 days. RESULTS: The overall mean percentage of time in range (70-180 mg/dL, 3.9-10 mmol/L) during hybrid closed-loop was 71.8% in the adult cohort and 69.8% in the adolescent cohort. The overall percentage of time spent under 70 mg/dL (3.9 mmol/L) was 2.0% in the adult cohort and 2.5% in the adolescent cohort. Mean glucose values were 152 mg/dL (8.4 mmol/L) in the adult cohort and 153 mg/dL (8.5 mmol/L) in the adolescent cohort. CONCLUSIONS: Closed-loop control using the Medtronic hybrid closed-loop system enables adaptive, real-time basal rate modulation. Initializing hybrid closed-loop in clinical practice will involve individualizing initiation parameters to optimize overall glucose control.


Asunto(s)
Actividades Cotidianas , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Glucosa/metabolismo , Hiperglucemia/prevención & control , Páncreas Artificial , Medicina de Precisión , Tejido Subcutáneo/efectos de los fármacos , Adolescente , Conducta del Adolescente , Adulto , Algoritmos , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea , Calibración , Estudios de Cohortes , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/metabolismo , Cálculo de Dosificación de Drogas , Monitoreo de Drogas , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/efectos adversos , Hipoglucemiantes/uso terapéutico , Insulina/administración & dosificación , Insulina/efectos adversos , Insulina/uso terapéutico , Páncreas Artificial/efectos adversos , Tejido Subcutáneo/metabolismo , Adulto Joven
6.
Sensors (Basel) ; 17(1)2017 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-28098839

RESUMEN

Reliable continuous glucose monitoring (CGM) enables a variety of advanced technology for the treatment of type 1 diabetes. In addition to artificial pancreas algorithms that use CGM to automate continuous subcutaneous insulin infusion (CSII), CGM can also inform fault detection algorithms that alert patients to problems in CGM or CSII. Losses in infusion set actuation (LISAs) can adversely affect clinical outcomes, resulting in hyperglycemia due to impaired insulin delivery. Prolonged hyperglycemia may lead to diabetic ketoacidosis-a serious metabolic complication in type 1 diabetes. Therefore, an algorithm for the detection of LISAs based on CGM and CSII signals was developed to improve patient safety. The LISA detection algorithm is trained retrospectively on data from 62 infusion set insertions from 20 patients. The algorithm collects glucose and insulin data, and computes relevant fault metrics over two different sliding windows; an alarm sounds when these fault metrics are exceeded. With the chosen algorithm parameters, the LISA detection strategy achieved a sensitivity of 71.8% and issued 0.28 false positives per day on the training data. Validation on two independent data sets confirmed that similar performance is seen on data that was not used for training. The developed algorithm is able to effectively alert patients to possible infusion set failures in open-loop scenarios, with limited evidence of its extension to closed-loop scenarios.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 1 , Humanos , Hipoglucemiantes , Insulina , Sistemas de Infusión de Insulina
7.
Cogn Affect Behav Neurosci ; 14(4): 1356-74, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24796598

RESUMEN

Configuring the mind to perform a novel task is an effortful process and one that is related to differences in general intelligence. Previous research has suggested that when participants are given instructions for a future task, representations of the rules contained in the instructions can influence subsequent behavior, even when the rules are not necessary to perform the upcoming task. One hypothesis for the continued activation of rule representations suggests that the practice trials participants perform before the experimental trials may instantiate the unnecessary task rules into participants' mental model of the task (i.e., the task space). To test this hypothesis, EEGs were recorded as participants (N = 66) completed a multirule task designed to contrast the effects of increasing task structure complexity and practice trial exposure. The results showed that, as was predicted, performance is significantly poorer when more task rules are specified in the task instructions. Practice trials with the extra rule did not affect task performance, indicating that an unacted verbal instruction is sufficient to incorporate the rule into participants' mental model of the task. The EEG results showed that instruction complexity was linked to a phasic increase in frontal theta synchronization but reduced posterior alpha and beta desynchronization. These changes in synchronization occurred during a time period of low intertrial phase coherence and suggest that participants were "checking the task rules" amidst a trial. This transient neural activity may reflect compensatory mechanisms for dealing with increased mind-wandering that is more likely to occur in complex tasks.


Asunto(s)
Ondas Encefálicas/fisiología , Encéfalo/fisiología , Diabetes Mellitus Tipo 1/patología , Práctica Psicológica , Análisis y Desempeño de Tareas , Adolescente , Encéfalo/fisiopatología , Mapeo Encefálico , Electroencefalografía , Femenino , Análisis de Fourier , Humanos , Pruebas de Inteligencia , Masculino , Pruebas Neuropsicológicas , Análisis de Componente Principal , Desempeño Psicomotor , Factores de Tiempo , Adulto Joven
8.
Value Health ; 17(5): 561-9, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25128049

RESUMEN

OBJECTIVE: To assess the cost-effectiveness of sensor-augmented insulin pump therapy with "Low Glucose Suspend" (LGS) functionality versus standard pump therapy with self-monitoring of blood glucose in patients with type 1 diabetes who have impaired awareness of hypoglycemia. METHODS: A clinical trial-based economic evaluation was performed in which the net costs and effectiveness of the two treatment modalities were calculated and expressed as an incremental cost-effectiveness ratio (ICER). The clinical outcome of interest for the evaluation was the rate of severe hypoglycemia in each arm of the LGS study. Quality-of-life utility scores were calculated using the three-level EuroQol five-dimensional questionnaire. Resource use costs were estimated using public sources. RESULTS: After 6 months, the use of sensor-augmented insulin pump therapy with LGS significantly reduced the incidence of severe hypoglycemia compared with standard pump therapy (incident rate difference 1.85 [0.17-3.53]; P = 0.037). Based on a primary randomized study, the ICER per severe hypoglycemic event avoided was $18,257 for all patients and $14,944 for those aged 12 years and older. Including all major medical resource costs (e.g., hospital admissions), the ICERs were $17,602 and $14,289, respectively. Over the 6-month period, the cost per quality-adjusted life-year gained was $40,803 for patients aged 12 years and older. CONCLUSIONS: Based on the Australian experience evaluating new interventions across a broad range of therapeutic areas, sensor-augmented insulin pump therapy with LGS may be considered a cost-effective alternative to standard pump therapy with self-monitoring of blood glucose in hypoglycemia unaware patients with type 1 diabetes.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemia/inducido químicamente , Hipoglucemiantes/uso terapéutico , Sistemas de Infusión de Insulina , Insulina/uso terapéutico , Australia , Glucemia/efectos de los fármacos , Automonitorización de la Glucosa Sanguínea/métodos , Análisis Costo-Beneficio , Diabetes Mellitus Tipo 1/economía , Humanos , Hipoglucemia/diagnóstico , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/economía , Incidencia , Insulina/administración & dosificación , Insulina/economía , Calidad de Vida , Años de Vida Ajustados por Calidad de Vida , Ensayos Clínicos Controlados Aleatorios como Asunto , Índice de Severidad de la Enfermedad , Encuestas y Cuestionarios
9.
Diabetes Technol Ther ; 26(6): 383-393, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38277156

RESUMEN

Background: To evaluate the long-term safety and effectiveness of the Omnipod® 5 Automated Insulin Delivery (AID) System in very young children with type 1 diabetes with up to 2 years of use. Methods: Following a 13-week single-arm, multicenter, pivotal trial that took place after 14 days of standard therapy data collection, participating children (2-5.9 years of age at study enrollment) were provided the option to continue use of the AID system in an extension phase. HbA1c was measured every 3 months, up to 15 months of total use, and continuous glucose monitor metrics were collected through the completion of the extension study (for up to 2 years). Results: Participants (N = 80) completed 18.2 [17.4, 23.4] (median [interquartile range]) total months of AID, inclusive of the 3-month pivotal trial. During the pivotal trial, HbA1c decreased from 7.4% ± 1.0% (57 ± 10.9 mmol/mol) to 6.9% ± 0.7% (52 ± 7.7 mmol/mol, P < 0.0001) and was maintained at 7.0% ± 0.7% (53 ± 7.7 mmol/mol) after 15 months total use (P < 0.0001 from baseline). Time in target range (70-180 mg/dL) increased from 57.2% ± 15.3% during standard therapy to 68.1% ± 9.0% during the pivotal trial (P < 0.0001) and was maintained at 67.2% ± 9.3% during the extension phase (P < 0.0001 from standard therapy). Participants spent a median 97.1% of time in Automated Mode during the extension phase, with one episode of severe hypoglycemia and one episode of diabetic ketoacidosis. Conclusion: This evaluation of the Omnipod 5 AID System indicates that long-term use can safely maintain improvements in glycemic outcomes with up to 2 years of use in very young children with type 1 diabetes. Clinical Trials Registration Number: NCT04476472.


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Hemoglobina Glucada , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Preescolar , Insulina/administración & dosificación , Insulina/uso terapéutico , Femenino , Masculino , Glucemia/análisis , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/uso terapéutico , Hemoglobina Glucada/análisis , Hipoglucemia/prevención & control , Resultado del Tratamiento , Control Glucémico/métodos , Automonitorización de la Glucosa Sanguínea
10.
Artículo en Inglés | MEDLINE | ID: mdl-38375861

RESUMEN

Background: The Omnipod® 5 Automated Insulin Delivery System was associated with favorable glycemic outcomes for people with type 1 diabetes (T1D) in two pivotal clinical trials. Real-world evidence is needed to explore effectiveness in nonstudy conditions. Methods: A retrospective analysis of the United States Omnipod 5 System users (aged ≥2 years) with T1D and sufficient data (≥90 days of data; ≥75% of days with ≥220 continuous glucose monitor readings/day) available in Insulet Corporation's device and person-reported datasets as of July 2023 was performed. Target glucose setting usage (i.e., 110-150 mg/dL in 10 mg/dL increments) was summarized and glycemic outcomes were examined. Subgroup analyses of those using the lowest average glucose target (110 mg/dL) and stratification by baseline characteristics (e.g., age, prior therapy, health insurance coverage) were conducted. Results: In total, 69,902 users were included. Multiple and higher glucose targets were more commonly used in younger age groups. Median percentage of time in range (TIR; 70-180 mg/dL) was 68.8%, 61.3%, and 53.6% for users with average glucose targets of 110, 120, and 130-150 mg/dL, respectively, with minimal time <70 mg/dL (all median <1.13%). Among those with an average glucose target of 110 mg/dL (n = 37,640), median TIR was 65.0% in children and adolescents (2-17 years) and 69.9% in adults (≥18 years). Subgroup analyses of users transitioning from Omnipod DASH or multiple daily injections and of Medicaid/Medicare users demonstrated favorable glycemic outcomes among these groups. Conclusion: These glycemic outcomes from a large and diverse sample of nearly 70,000 children and adults demonstrate effective use of the Omnipod 5 System under real-world conditions.

11.
Diabetes Technol Ther ; 26(1): 11-23, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37850941

RESUMEN

Background: The Omnipod® 5 Automated Insulin Delivery (AID) System was shown to be safe and effective following 3 months of use in people with type 1 diabetes (T1D); however, data on the durability of these results are limited. This study evaluated the long-term safety and effectiveness of Omnipod 5 use in people with T1D during up to 2 years of use. Materials and Methods: After a 3-month single-arm, multicenter, pivotal trial in children (6-13.9 years) and adolescents/adults (14-70 years), participants could continue system use in an extension phase. HbA1c was measured every 3 months for up to 15 months; continuous glucose monitor metrics were collected for up to 2 years. Results: Participants (N = 224) completed median (interquartile range) 22.3 (21.7, 22.7) months of AID. HbA1c was reduced in the pivotal trial from 7.7% ± 0.9% in children and 7.2% ± 0.9% in adolescents/adults to 7.0% ± 0.6% and 6.8% ± 0.7%, respectively, (P < 0.0001), and was maintained at 7.2% ± 0.7% and 6.9% ± 0.6% after 15 months (P < 0.0001 from baseline). Time in target range (70-180 mg/dL) increased from 52.4% ± 15.6% in children and 63.6% ± 16.5% in adolescents/adults at baseline to 67.9% ± 8.0% and 73.8% ± 10.8%, respectively, during the pivotal trial (P < 0.0001) and was maintained at 65.9% ± 8.9% and 72.9% ± 11.3% during the extension (P < 0.0001 from baseline). One episode of diabetic ketoacidosis and seven episodes of severe hypoglycemia occurred during the extension. Children and adolescents/adults spent median 96.1% and 96.3% of time in Automated Mode, respectively. Conclusion: Our study supports that long-term use of the Omnipod 5 AID System can safely maintain improvements in glycemic outcomes for up to 2 years of use in people with T1D. Clinical Trials Registration Number: NCT04196140.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Niño , Humanos , Adolescente , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Hemoglobina Glucada , Sistemas de Infusión de Insulina , Glucemia , Automonitorización de la Glucosa Sanguínea
12.
JAMA ; 310(12): 1240-7, 2013 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-24065010

RESUMEN

IMPORTANCE: Hypoglycemia is a critical obstacle to the care of patients with type 1 diabetes. Sensor-augmented insulin pump with automated low-glucose insulin suspension has the potential to reduce the incidence of major hypoglycemic events. OBJECTIVE: To determine the incidence of severe and moderate hypoglycemia with sensor-augmented pump with low-glucose suspension compared with standard insulin pump therapy. DESIGN, SETTING, AND PARTICIPANTS: A randomized clinical trial involving 95 patients with type 1 diabetes, recruited from December 2009 to January 2012 in Australia. INTERVENTIONS: Patients were randomized to insulin pump only or automated insulin suspension for 6 months. MAIN OUTCOMES AND MEASURES: The primary outcome was the combined incidence of severe (hypoglycemic seizure or coma) and moderate hypoglycemia (an event requiring assistance for treatment). In a subgroup, counterregulatory hormone responses to hypoglycemia were assessed using the hypoglycemic clamp technique. RESULTS: Of the 95 patients randomized, 49 were assigned to the standard-pump (pump-only) therapy and 46 to the low-glucose suspension group. The mean (SD) age was 18.6 (11.8) years; duration of diabetes, 11.0 (8.9) years; and duration of pump therapy, 4.1 (3.4) years. The baseline rate of severe and moderate hypoglycemic events in the pump-only group was 20.7 vs 129.6 events per 100 patient months in the low-glucose suspension group. After 6 months of treatment, the event rates decreased from 28 to 16 in the pump-only group vs 175 to 35 in the low-glucose suspension group. The adjusted incidence rate per 100 patient-months was 34.2 (95% CI, 22.0-53.3) for the pump-only group vs 9.5 (95% CI, 5.2-17.4) for the low-glucose suspension group. The incidence rate ratio was 3.6 (95% CI, 1.7-7.5; P <.001). There was no change in glycated hemoglobin in either group: mean, 7.4 (95% CI, 7.2-7.6) to 7.4 (95% CI, 7.2-7.7) in the pump-only group vs mean, 7.6 (95%, CI, 7.4-7.9) to 7.5 (95% CI, 7.3-7.7) in the low-glucose suspension group. Counterregulatory hormone responses to hypoglycemia were not changed. There were no episodes of diabetic ketoacidosis or hyperglycemia with ketosis. CONCLUSIONS AND RELEVANCE: Sensor-augmented pump therapy with automated insulin suspension reduced the combined rate of severe and moderate hypoglycemia in patients with type 1 diabetes. TRIAL REGISTRATION: anzctr.org.au Identifier: ACTRN12610000024044.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemia/inducido químicamente , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Adolescente , Adulto , Glucemia/efectos de los fármacos , Niño , Preescolar , Cetoacidosis Diabética/inducido químicamente , Femenino , Humanos , Hipoglucemiantes/efectos adversos , Insulina/efectos adversos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Adulto Joven
13.
Diabetes Care ; 46(4): 742-750, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36787903

RESUMEN

OBJECTIVE: Automated insulin delivery (AID) has rarely been studied in adults with type 2 diabetes. We tested the feasibility of using AID for type 2 diabetes with the Omnipod 5 System in a multicenter outpatient trial. RESEARCH DESIGN AND METHODS: Participants previously were using either basal-only or basal-bolus insulin injections, with or without the use of a continuous glucose monitor (CGM), and had a baseline HbA1c ≥8% (≥64 mmol/mol). Participants completed 2 weeks of CGM sensor data collection (blinded for those not previously using CGM) with their standard therapy (ST), then transitioned to 8 weeks of AID. Participants who previously used basal-only injections used the AID system in manual mode for 2 weeks before starting AID. Antihyperglycemic agents were continued at clinician discretion. Primary safety outcomes were percentage of time with sensor glucose ≥250 mg/dL and <54 mg/dL during AID. Additional outcomes included HbA1c and time in target range (TIR) (70-180 mg/dL). RESULTS: Participants (N = 24) had a mean (± SD) age of 61 ± 8 years, baseline HbA1c of 9.4% ± 0.9% (79 ± 10 mmol/mol), and diabetes duration of 19 ± 9 years. Percentage of time with sensor glucose ≥250 mg/dL decreased with AID by 16.9% ± 16.2% (P < 0.0001), whereas percentage of time at <54 mg/dL remained low during both ST and AID (median [interquartile range] 0.0% [0.00%, 0.06%] vs. 0.00% [0.00%, 0.03%]; P = 0.4543). HbA1c (± SD) decreased by 1.3% ± 0.7% (14 ± 8 mmol/mol; P < 0.0001) and TIR increased by 21.9% ± 15.2% (P < 0.0001) without a significant change in total daily insulin or BMI with AID. CONCLUSIONS: Findings from this feasibility trial of AID in adults with type 2 diabetes with suboptimal glycemic outcomes justify further evaluation of this technology in this population.


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Adulto , Humanos , Persona de Mediana Edad , Anciano , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Hemoglobina Glucada , Automonitorización de la Glucosa Sanguínea , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Glucemia , Insulina Regular Humana/uso terapéutico , Sistemas de Infusión de Insulina
14.
Diabetes Ther ; 14(3): 593-610, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36763329

RESUMEN

INTRODUCTION: Despite recent advances in diabetes technology, most people living with type 1 diabetes mellitus (T1D) are unable to meet glycemic targets. Real-world evidence can provide insight into outcomes achieved with specific treatment devices when used in clinical practice. The aim of this study was to analyze real-world outcomes collected from a large cohort of people living with T1D and initiating treatment with the Omnipod DASH System. METHODS: In this retrospective observational study, real-world outcomes were analyzed from a database of information collected from people with T1D initiating the Omnipod DASH System. Information in the database was either taken directly from the patient's medical record or self-reported if medical records were unavailable. The primary outcome was change in glycated hemoglobin (HbA1c) from baseline (before initiation) to 3 months after initiation. Secondary outcomes were changes in total daily dose of insulin (TDD) and self-reported frequency of hypoglycemic events (< 70 mg/dL). Results are separated for the adult (≥ 18 years, N = 3341) and pediatric (< 18 years, N = 1397) cohorts. RESULTS: The change in HbA1c from baseline was - 0.9 ± 1.6% ( - 10 ± 18 mmol/mol; p < 0.0001) in adults and - 0.9 ± 2.0% ( - 10 ± 22 mmol/mol; p < 0.0001) in the pediatric cohort. For those previously using multiple daily injections, HbA1c decreased by - 1.0 ± 1.7% ( - 11 ± 19 mmol/mol) in adults and - 1.0 ± 2.1% ( - 11 ± 23 mmol/mol) in the pediatric cohort (both p < 0.0001). Hypoglycemic events decreased in adults from 2.9 to 1.3 episodes per week ( - 1.6 ± 3.2 events/week; p < 0.0001), and in the pediatric cohort from 2.8 to 1.5 episodes per week ( - 1.3 ± 2.7 events/week; p < 0.0001). In adults, TDD decreased by 19.9% (p < 0.0001), and it remained stable in the pediatric cohort (p > 0.05). CONCLUSIONS: Real-world outcomes from this large cohort of people initiating therapy with the Omnipod DASH System showed significant improvement in HbA1c and a substantial reduction in hypoglycemic events after 3 months of use.

15.
Diabetes Technol Ther ; 25(10): 677-688, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37578778

RESUMEN

Introduction: Multiple daily injection insulin therapy frequently fails to meet hospital glycemic goals and is prone to hypoglycemia. Automated insulin delivery (AID) with remote glucose monitoring offers a solution to these shortcomings. Research Design and Methods: In a single-arm multicenter pilot trial, we tested the feasibility, safety, and effectiveness of the Omnipod 5 AID System with real-time continuous glucose monitoring (CGM) for up to 10 days in hospitalized patients with insulin-requiring diabetes on nonintensive care unit medical-surgical units. Primary endpoints included the proportion of time in automated mode and percent time-in-range (TIR 70-180 mg/dL) among participants with >48 h of CGM data. Safety endpoints included incidence of severe hypoglycemia and diabetes-related ketoacidosis (DKA). Additional glycemic endpoints, CGM accuracy, and patient satisfaction were also explored. Results: Twenty-two participants were enrolled; 18 used the system for a total of 96 days (mean 5.3 ± 3.1 days per patient), and 16 had sufficient CGM data required for analysis. Median percent time in automated mode was 95% (interquartile range 92%-98%) for the 18 system users, and the 16 participants with >48 h of CGM data achieved an overall TIR of 68% ± 16%, with 0.17% ± 0.3% time <70 mg/dL and 0.06% ± 0.2% time <54 mg/dL. Sensor mean glucose was 167 ± 21 mg/dL. There were no DKA or severe hypoglycemic events. All participants reported satisfaction with the system at study end. Conclusions: The use of AID with a disposable tubeless patch-pump along with remote real-time CGM is feasible in the hospital setting. These results warrant further investigation in randomized trials.


Asunto(s)
Diabetes Mellitus Tipo 1 , Cetoacidosis Diabética , Hipoglucemia , Humanos , Glucemia , Automonitorización de la Glucosa Sanguínea/métodos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Estudios de Factibilidad , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Insulina Regular Humana/uso terapéutico , Proyectos Piloto
16.
Diabetes Technol Ther ; 24(1): 18-25, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34491825

RESUMEN

Background: Expert opinion guidelines and limited data from clinical trials recommend adjustment to bolus insulin doses based on continuous glucose monitor (CGM) trend data, yet minimal evidence exists to support this approach. We performed a clinical evaluation of a novel CGM-informed bolus calculator (CIBC) with automatic insulin bolus dose adjustment based on CGM trend used with sensor-augmented pump therapy. Materials and Methods: In this multicenter, outpatient study, participants 6-70 years of age with type 1 diabetes (T1D) used the Omnipod® 5 System in Manual Mode, first for 7 days without a connected CGM (standard bolus calculator, SBC, phase 1) and then for 7 days with a connected CGM using the CIBC (CIBC phase 2). The integrated bolus calculator used stored pump settings plus user-estimated meal size and/or either a manually entered capillary glucose value (SBC phase) or an imported current CGM value and trend (CIBC phase) to recommend a bolus amount. The CIBC automatically increased or decreased the suggested bolus amount based on the CGM trend. Results: Twenty-five participants, (mean ± standard deviation) 27 ± 15 years of age, with T1D duration 12 ± 9 years and A1C 7.0% ± 0.9% completed the study. There were significantly fewer sensor readings <70 mg/dL 4 h postbolus with the CIBC compared to the SBC (2.1% ± 2.0% vs. 2.8 ± 2.7, P = 0.03), while percent of sensor readings >180 and 70-180 mg/dL remained the same. There was no difference in insulin use or number of boluses given between the two phases. Conclusion: The CIBC was safe when used with the Omnipod 5 System in Manual Mode, with fewer hypoglycemic readings in the postbolus period compared to the SBC. This trial was registered at ClinicalTrials.gov (NCT04320069).


Asunto(s)
Diabetes Mellitus Tipo 1 , Glucosa , Adolescente , Adulto , Glucemia , Automonitorización de la Glucosa Sanguínea , Niño , Preescolar , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada/análisis , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Adulto Joven
17.
Diabetes Res Clin Pract ; 190: 109998, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35853530

RESUMEN

AIMS: To evaluate psychosocial outcomes for adults with type 1 diabetes (T1D) using the tubeless Omnipod® 5 Automated Insulin Delivery (AID) System. METHODS: A single-arm, multicenter (across the United States), prospective safety and efficacy study of the tubeless AID system included 115 adults with T1D. Participants aged 18-70 years completed questionnaires assessing psychosocial outcomes - diabetes distress (T1-DDS), hypoglycemic confidence (HCS), well-being (WHO-5), sleep quality (PSQI), insulin delivery satisfaction (IDSS), diabetes treatment satisfaction (DTSQ), and system usability (SUS) - before and after 3 months of AID use. Associations among participant characteristics, psychosocial measures and glycemic outcomes were evaluated using linear regression analyses. RESULTS: Adults using the tubeless AID system demonstrated improvements in diabetes-specific psychosocial measures, including diabetes distress, hypoglycemic confidence, insulin delivery satisfaction, diabetes treatment satisfaction, and system usability after 3 months (all P < 0.001). No changes in general well-being or sleep quality were observed. The psychosocial outcomes assessed were not consistently associated with baseline participant characteristics (i.e., age, sex, diabetes duration, glycemic outcomes including percent time in range 70-180 mg/dL, percent time below range < 70 mg/dL, hemoglobin A1c, or insulin regimen). CONCLUSIONS: Use of the Omnipod 5 AID system was associated with significant improvements in diabetes-related psychosocial outcomes for adults with T1D. CLINICAL TRIALS REGISTRATION NUMBER: NCT04196140.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/psicología , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Insulina Regular Humana/uso terapéutico , Estudios Prospectivos
18.
Diabetes Care ; 45(8): 1907-1910, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35678724

RESUMEN

OBJECTIVE: Very young children with type 1 diabetes often struggle to achieve glycemic targets, putting them at risk for long-term complications and creating an immense management burden for caregivers. We conducted the first evaluation of the Omnipod 5 Automated Insulin Delivery System in this population. RESEARCH DESIGN AND METHODS: A total of 80 children aged 2.0-5.9 years used the investigational system in a single-arm study for 13 weeks following 14 days of baseline data collection with their usual therapy. RESULTS: There were no episodes of severe hypoglycemia or diabetic ketoacidosis. By study end, HbA1c decreased by 0.55% (6.0 mmol/mol) (P < 0.0001). Time with sensor glucose levels in target range 70-180 mg/dL increased by 10.9%, or 2.6 h/day (P < 0.0001), while time with levels <70 mg/dL declined by median 0.27% (P = 0.0204). CONCLUSIONS: Use of the automated insulin delivery system was safe, and participants experienced improved glycemic measures and reduced hypoglycemia during the study phase compared with baseline.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Glucemia , Niño , Preescolar , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/epidemiología , Hemoglobina Glucada/análisis , Humanos , Hipoglucemia/epidemiología , Hipoglucemiantes/efectos adversos , Insulina/efectos adversos , Sistemas de Infusión de Insulina , Insulina Regular Humana/uso terapéutico
19.
Diabetes Res Clin Pract ; 174: 108735, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33711396

RESUMEN

AIMS: To compare glycemic outcomes in adults with type 2 diabetes mellitus (T2DM) before and 90 days after initiating Omnipod® or Omnipod DASH® Insulin Management Systems. METHODS: In this retrospective observational study (N = 3,592) change in HbA1c level, total daily dose (TDD) of insulin (n = 3,053), and frequency of self-reported hypoglycemic events (HE, <70 mg/dL, n = 2,922) were assessed overall and by prior treatment modality (multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII)), age group, and baseline HbA1c category. RESULTS: Change (mean ± SD) in HbA1c was -1.3 ± 1.7% [-14 ± 19 mmol/mol] overall, -1.4 ± 1.7% [-15 ± 19 mmol/mol] for prior MDI users, and -0.9 ± 1.5% [-10 ± 16 mmol/mol] for prior CSII users (p<0.0001). The percentage of patients with HbA1c ≥9% [≥75 mmol/mol] decreased (49% to 19%), and with HbA1c <7% [<53 mmol/mol] increased (10% to 22%) (p<0.0001). Prior therapy, age, and baseline HbA1c category were factors affecting change in HbA1c (p<0.05). Reductions in TDD (overall, -33 ± 52U, p<0.0001) and HE per week (overall, -0.5 ± 2.0, p<0.0001), were seen regardless of prior treatment, age, or baseline HbA1c. CONCLUSIONS: Omnipod System use was associated with statistically and clinically meaningful reductions in HbA1c, TDD, and HE compared to prior treatments in T2DM.


Asunto(s)
Diabetes Mellitus Tipo 2/tratamiento farmacológico , Control Glucémico/métodos , Insulina/uso terapéutico , Adolescente , Adulto , Anciano , Femenino , Humanos , Insulina/farmacología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
20.
Diabetes Care ; 44(2): 610-613, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33328284

RESUMEN

OBJECTIVE: Exercising while fasted with type 1 diabetes facilitates weight loss; however, the best strategy to maintain glucose stability remains unclear. RESEARCH DESIGN AND METHODS: Fifteen adults on continuous subcutaneous insulin infusion completed three sessions of fasted walking (120 min at 45% VO2max) in a randomized crossover design: 50% basal rate reduction, set 90 min pre-exercise (-90min50%BRR); usual basal rate with carbohydrate intake of 0.3 g/kg/h (CHO-only); and combined 50% basal rate reduction set at exercise onset with carbohydrate intake of 0.3 g/kg/h (Combo). RESULTS: Combo had a smaller change in glucose (5 ± 47 mg/dL) versus CHO-only (-49 ± 61 mg/dL, P = 0.03) or -90min50%BRR (-34 ± 45 mg/dL). The -90min50%BRR strategy produced higher ß-hydroxybutyrate levels (0.4 ± 0.3 vs. 0.1 ± 0.1 mmol/L) and greater fat oxidation (0.51 ± 0.2 vs. 0.39 ± 0.1 g/min) than CHO-only (both P < 0.05). CONCLUSIONS: All strategies examined produced stable glycemia for fasted exercise, but a 50% basal rate reduction, set 90 min pre-exercise, eliminates carbohydrate needs and enhances fat oxidation better than carbohydrate feeding with or without a basal rate reduction set at exercise onset.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Glucemia , Estudios Cruzados , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Carbohidratos de la Dieta , Ejercicio Físico , Humanos , Insulina/uso terapéutico , Sistemas de Infusión de Insulina
SELECCIÓN DE REFERENCIAS