Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Phys Rev Lett ; 123(3): 031302, 2019 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-31386435

RESUMEN

We present new constraints on the dark matter-induced annual modulation signal using 1.7 years of COSINE-100 data with a total exposure of 97.7 kg yr. The COSINE-100 experiment, consisting of 106 kg of NaI(Tl) target material, is designed to carry out a model-independent test of DAMA/LIBRA's claim of WIMP discovery by searching for the same annual modulation signal using the same NaI(Tl) target. The crystal data show a 2.7 cpd/kg/keV background rate on average in the 2-6 keV energy region of interest. Using a χ-squared minimization method we observe best fit values for modulation amplitude and phase of 0.0092±0.0067 cpd/kg/keV and 127.2±45.9 d, respectively.

2.
Phys Rev Lett ; 122(13): 131802, 2019 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-31012610

RESUMEN

A search for inelastic boosted dark matter (IBDM) using the COSINE-100 detector with 59.5 days of data is presented. This relativistic dark matter is theorized to interact with the target material through inelastic scattering with electrons, creating a heavier state that subsequently produces standard model particles, such as an electron-positron pair. In this study, we search for this electron-positron pair in coincidence with the initially scattered electron as a signature for an IBDM interaction. No excess over the predicted background event rate is observed. Therefore, we present limits on IBDM interactions under various hypotheses, one of which allows us to explore an area of the dark photon parameter space that has not yet been covered by other experiments. This is the first experimental search for IBDM using a terrestrial detector.

3.
Eur Phys J C Part Fields ; 78(6): 490, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30956554

RESUMEN

The COSINE-100 dark matter search experiment is an array of NaI(Tl) crystal detectors located in the Yangyang Underground Laboratory (Y2L). To understand measured backgrounds in the NaI(Tl) crystals we have performed Monte Carlo simulations using the Geant4 toolkit and developed background models for each crystal that consider contributions from both internal and external sources, including cosmogenic nuclides. The background models are based on comparisons of measurement data with Monte Carlo simulations that are guided by a campaign of material assays and are used to evaluate backgrounds and identify their sources. The average background level for the six crystals (70 kg total mass) that are studied is 3.5 counts/day/keV/kg in the (2-6) keV energy interval. The dominant contributors in this energy region are found to be 210 Pb and 3 H.

4.
Am J Gastroenterol ; 63(2): 166-8, 1975 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-1130392

RESUMEN

A juvenile colon polyp was demonstrated by inferior mesenteric arteriography in a 21-year old man with recurrent, massive, unexplained gastrointestinal bleeding. The arteriogram demonstrated a mucosal blush at the tip of the polyp along with a solitary prominent draining vein in the stalk and a nest of draining veins at the base of the stalk.


Asunto(s)
Colon/irrigación sanguínea , Neoplasias del Colon/diagnóstico por imagen , Pólipos Intestinales/diagnóstico por imagen , Arterias Mesentéricas/diagnóstico por imagen , Venas Mesentéricas/diagnóstico por imagen , Adulto , Angiografía , Colon/patología , Neoplasias del Colon/patología , Humanos , Pólipos Intestinales/patología , Masculino
5.
Radiology ; 125(2): 379-82, 1977 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-910048

RESUMEN

Analysis of a series of 352 femoral angiograms revealed that "blind" cannulation of the femoral artery distal to an occluded aorta or iliac artery is technically feasible in most patients. The vessel is usually patent even when the pulse is absent. Blind cannulation is not necessary for satisfactory peripheral angiography in all cases, but it is useful whenever visualization of the peripheral circulation is unsatisfactory following aortic injection. There were no apparent complications from the use of the technique.


Asunto(s)
Arteria Femoral/diagnóstico por imagen , Aortografía , Arteriopatías Oclusivas/diagnóstico por imagen , Cateterismo/métodos , Femenino , Humanos , Arteria Ilíaca/diagnóstico por imagen
6.
J Am Optom Assoc ; 57(12): 882-3, 1986 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-3794159
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA