Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Gen Dent ; 68(3): 57-61, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32348245

RESUMEN

The objective of this clinical case report is to describe the late treatment performed in a 10-year-old patient who suffered a complicated crown fracture associated with luxation of the maxillary left central incisor. The patient-s parents reported that the patient fell and was immediately taken to a hospital, where radiographs, splinting, and suturing were performed and an anti-inflammatory prescription was provided, but no treatment was given for the exposed pulp. The parents and patient sought treatment at a pediatric dentistry clinic 16 days post-trauma. The clinical examination revealed the presence of a left central incisor with a fracture of enamel and dentin involving the pulp, which was necrotic, and a splint extending from the right lateral incisor to the left lateral incisor. However, it was not possible to diagnose the type of luxation that had occurred. The fractured incisor was treated with periodic changes of calcium hydroxide dressing for apexification for 10 months, and the root was subsequently obturated with gutta percha and root canal sealer. The tooth fragment was stored in physiologic solution during this time. After obturation, tooth darkening was observed, and LED-assisted tooth bleaching was accomplished prior to reattachment of the fractured fragment. The tooth was reexamined every 6 months. Two years after the traumatic event, the left central incisor was infraoccluded in relation to the right central incisor. A radiograph confirmed ankylosis of the traumatized tooth. When trauma affects the enamel, dentin, pulp, and supporting tissues, the prognosis can be unfavorable even when late treatment is adequate, especially when a tooth in a growing patient has points of ankylosis.


Asunto(s)
Anquilosis del Diente , Avulsión de Diente/complicaciones , Fracturas de los Dientes/terapia , Niño , Coronas , Humanos , Tratamiento del Conducto Radicular , Corona del Diente , Raíz del Diente
2.
Gen Dent ; 67(1): 47-50, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30644831

RESUMEN

Zirconia-reinforced lithium silicate (ZLS) has recently been introduced in an effort to improve the mechanical properties of glass-ceramic materials. In vitro evaluations suggest that this class of material has high flexural strength and exhibits satisfactory adhesion to resin cement and wear resistance. Since few clinical reports of this novel material are currently available, the aim of this case report is to describe clinical perceptions regarding the handling and performance of ZLS ceramics when used for laminate veneers on the maxillary incisors.


Asunto(s)
Cerámica/química , Porcelana Dental , Litio , Silicatos/química , Circonio/química , Recubrimiento Dental Adhesivo/métodos , Estudios de Seguimiento , Humanos , Litio/química , Ensayo de Materiales , Propiedades de Superficie
3.
Am J Dent ; 27(4): 195-8, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25831602

RESUMEN

PURPOSE: To evaluate the effects of toothbrushing abrasion associated with pH cycling on the surface roughness and wear of methacrylate- and silorane-based resin composites. METHODS: Microhybrid methacrylate-based (Filtek Z250), nanofilled methacrylate-based (Filtek Supreme Ultra) and microhybrid silorane-based (Filtek LS) composites were selected for this investigation. For each composite, two groups (n = 10) of rectangular specimens were made. The initial roughness (Ra) of all of the groups was evaluated based on the average of three random tracings with a profilometer, and each specimen had half of its surface protected with two layers of nail varnish to serve as controls. Half of the specimens of each resin were submitted to pH cycling, while the other half were stored in deionized water for 14 days. Subsequently, 100,000 strokes of simulated toothbrushing were performed. Final roughness and wear were measured with the same profilometer, and the values were submitted to ANOVA, Student's t-test and Tukey's test (P < 0.05). RESULTS: The data revealed an increase in surface roughness for Filtek Z250 and Filtek Supreme Ultra after toothbrushing, while Filtek LS showed the opposite behavior. Methacrylate-based composites presented lower wear values [Z250 (4.19 ± 1.73 µm); Supreme Ultra (4.16 ± 0.95 µm)], while the silorane-based composite presented increased surface roughness (11.51 ± 5.69 µm), particularly when submitted to pH cycling (15.31 ± 5.41 µm). Despite the good properties of silorane-based composites, particularly its smooth surface roughness even after pH cycling and toothbrushing abrasion, this composite still presented increased wear, which is an important issue for the development of new resin compositions.


Asunto(s)
Resinas de Silorano , Cepillado Dental , Concentración de Iones de Hidrógeno , Propiedades de Superficie
4.
Dent Mater J ; 40(1): 150-156, 2021 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-32999257

RESUMEN

This study aimed to analyze the interaction of a MDP-based universal dentin bonding system (DBS) with Er, Cr: YSGG laser irradiation, measuring the microtensile bond strength to dentin over a six-month period. The experimental design involved three factors: DBS (Adper Scotchbond Universal; Clearfil SE Bond, Adper Scotchbond Multipurpose and Adper Single Bond 2), laser (Control and Er, Cr: YSGG), and time (initial- 7 days and 6 months). Eighty dentin samples from molars were prepared (n=10) with laser irradiation after primer and DBS application. After 7 days, were subjected to micro tensile bond strength test. The data were analyzed by three-way ANOVA and Tukey tests (p<0.05). Both DBS and laser significantly affected the bonding performance and their interaction was statistically significant (p=0.0194). The self-etching mode of the MDP-based universal DBS maintained the bond strength on dentin irradiated with ER, Cr: YSGG after 6 months, while bonding with all other DBS deteriorated.


Asunto(s)
Recubrimiento Dental Adhesivo , Láseres de Estado Sólido , Dentina , Recubrimientos Dentinarios , Cementos de Resina , Resistencia a la Tracción
5.
Braz Dent J ; 30(6): 592-598, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31800754

RESUMEN

This study aimed to evaluate the polymerization properties of bulk-fill materials (low and high-viscosity) by using high-intensity continuous light and intermittent photo-activation in terms of polymerization shrinkage stress and degree of conversion (DC). The following Bulk-fill and Conventional nanofilled resin composites were evaluated: Filtek Z350XT Flow (3M/ESPE), SureFil SDR Flow (Dentsply), Filtek Bulk Fill Flow (3M/ESPE), Filtek Z350XT (3M/ESPE) and Filtek Bulk Fill Posterior (3M/ESPE). A LED device (DB 685, Dabi Atlante) was used for both protocols: continuous uniform and intermittent photo-activation (light-on and light-off cycles) with identical radiant exposure (14 J/cm2). The polymerization shrinkage stress (n=6) was evaluated by inserting a single increment of 12 mm3 between two stainless steel plates (6×2 mm) adapted to a Universal Testing Machine (UTM), at different times. Measurements were recorded after photo-activation. The degree of conversion was evaluated by Fourier transformed infrared spectroscope (FTIR) with an attenuated total reflectance (ATR) accessory (n=5). Data were analyzed by three-way ANOVA and Tukey's HSD (α=0.05) tests. Bulk Fill Posterior presented higher shrinkage stress values when photo-activated with the intermittent technique (p<0.05). The intermittent photo-activation increased the degree of conversion for the low-viscosity bulk-fills (p<0.05). Therefore, the use of modulated photo-activation (intermittent) must be indicated with caution since its use can influence the shrinkage stress and degree of conversion of composites, which varies according to the resin formulations.


Asunto(s)
Resinas Compuestas , Ensayo de Materiales , Polimerizacion , Viscosidad
6.
Compend Contin Educ Dent ; 38(3): 144-149; quiz 150, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28257221

RESUMEN

Often, young patients (≤30 years old) present with carious lesions that progress acutely, compromising a large amount of tooth structure. In these cases, a treatment to prevent the occurrence of pulp exposure and promote remineralization of caries-affected dentin is necessary to maintain healthy dental structure and allow more conservative interventions. The approach will be different when pulp exposure occurs: The therapeutic treatments will be focused on reparative dentin formation and prevention of microorganisms penetrating the pulp organ. Due to the different possible treatments that can be performed to avoid pulp necrosis and the various materials that can be used for this purpose, professionals may have some difficulties understanding all the indications for conservative pulp treatments. The objective of this article is to describe and discuss a successful pulp capping and stepwise excavation associated with restorative treatment for deep caries lesions of anterior upper teeth.


Asunto(s)
Caries Dental/terapia , Recubrimiento de la Pulpa Dental , Necrosis de la Pulpa Dental/prevención & control , Restauración Dental Permanente/métodos , Niño , Preparación de la Cavidad Dental , Humanos , Masculino , Remineralización Dental
7.
J Appl Oral Sci ; 25(4): 381-386, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28877276

RESUMEN

OBJECTIVE: This study aimed to investigate the effect of laser diode irradiation on the degree of conversion (DC), water sorption (WS), and water solubility (WSB) of these bonding systems in an attempt to improve their physico-mechanical resistance. MATERIAL AND METHODS: Two bonding agents were tested: a two-step total-etch system [Adper™ Single Bond 2, 3M ESPE (SB)] and a universal system [Adper™ Single Bond Universal, 3M ESPE (SU)]. Square-shaped specimens were prepared and assigned into 4 groups (n=5): SB and SU (control groups - no laser irradiation) and SB-L and SU-L [SB and SU laser (L) - irradiated groups]. DC was assessed using Fourier transform infrared spectroscopy with attenuated total reflectance. Additional uncured resin samples (≈3.0 µL, n=5) of each adhesive were also scanned for final DC calculation. For WS/WSB tests, similar specimens (n=10) were prepared and measured by monitoring the mass changes after dehydration/water storage cycles. For both tests, adhesive fluids were dropped into standardized Teflon molds (6.0×6.0×1.0 mm), irradiated with a 970-nm laser diode, and then polymerized with an LED-curing unit (1 W/cm2). RESULTS: Laser irradiation immediately before photopolymerization increased the DC (%) of the tested adhesives: SB-L>SB>SU-L>SU. For WS/WSB (µg/mm3), only the dentin bonding system (DBS) was a significant factor (p<0.05): SB>SU. CONCLUSION: Irradiation with a laser diode improved the degree of conversion of all tested simplified dentin bonding systems, with no impact on water sorption and solubility.


Asunto(s)
Recubrimientos Dentinarios/efectos de la radiación , Láseres de Semiconductores , Polimerizacion/efectos de la radiación , Luces de Curación Dental , Cementos Dentales/química , Cementos Dentales/efectos de la radiación , Recubrimientos Dentinarios/química , Curación por Luz de Adhesivos Dentales/métodos , Transición de Fase/efectos de la radiación , Procesos Fotoquímicos/efectos de la radiación , Valores de Referencia , Reproducibilidad de los Resultados , Solubilidad/efectos de la radiación , Espectroscopía Infrarroja por Transformada de Fourier , Estadísticas no Paramétricas , Propiedades de Superficie/efectos de la radiación
8.
Braz Dent J ; 27(5): 532-536, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27982229

RESUMEN

This in vitro study evaluated the effect of sodium bicarbonate and sodium ascorbate on the microtensile bond strength of an etch-and-rinse system to bleached bovine enamel. Sixty bovine enamel blocks (4x4 mm) were flattened and randomly allocated into 5 groups: G1 (negative control): without treatment; G2 (positive control): bleached with 35% hydrogen peroxide (HP); G3: bleached and stored for 7 days in artificial saliva before restorative procedures; G4: bleached and treated with 10% sodium bicarbonate solution for 5 min; G5: bleached and treated with 10% sodium ascorbate hydrogel for 15 min. HP gel was applied twice (20 min each, except in G1) and the adhesive restorations were performed. After 24 h, the specimens were sectioned into sticks and submitted to microtensile bond strength testing with a crosshead speed of 0.5 mm/min (n=12). As a complementary visual observation, the enamel surfaces of the G1 and G2 specimens were evaluated with scanning electron microscopy. Data were analyzed by one-way ANOVA (p<0.05). The means (standard deviation) were: G1: 24.22±7.74; G2: 18.29±5.88; G3: 40.88±7.95; G4: 19.95±5.67 and G5: 24.43±6.43. Adhesive failures were predominant in all groups. The comparison between the treatments indicates that waiting 7 days after bleaching is still the most effective approach. When this waiting period is not possible, application of sodium ascorbate or sodium bicarbonate seems to be a good alternative. Therefore, the practicality of obtaining sodium bicarbonate in the bleaching kits and its higher stability enables its clinical use.


Asunto(s)
Antioxidantes/farmacología , Esmalte Dental , Resistencia a la Tracción , Blanqueamiento de Dientes , Animales , Bovinos
9.
J Appl Oral Sci ; 24(4): 317-24, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27556201

RESUMEN

OBJECTIVE: This study investigated the effect of the fluorescent dye rhodamine B (RB) for interfacial micromorphology analysis of dental composite restorations on water sorption/solubility (WS/WSL) and microtensile bond strength to dentin (µTBS) of a 3-step total etch and a 2-step self-etch adhesive system. MATERIAL AND METHODS: The adhesives Adper Scotchbond Multi-Purpose (MP) and Clearfil SE Bond (SE) were mixed with 0.1 mg/mL of RB. For the WS/WSL tests, cured resin disks (5.0 mm in diameter x 0.8 mm thick) were prepared and assigned into four groups (n=10): MP, MP-RB, SE, and SE-RB. For µTBS assessment, extracted human third molars (n=40) had the flat occlusal dentin prepared and assigned into the same experimental groups (n=10). After the bonding and restoration procedures, specimens were sectioned in rectangular beams, stored in water and tested after seven days or after 12 months. The failure mode of fractured specimens was qualitatively evaluated under optical microscope (x40). Data from WS/WSL and µTBS were assessed by one-way and three-way ANOVA, respectively, and Tukey's test (α=5%). RESULTS: RB increased the WSL of MP and SE. On the other hand, WS of both MP and SE was not affected by the addition of RB. No significance in µTBS between MP and MP-RB for seven days or one year was observed, whereas for SE a decrease in the µTBS means occurred in both storage times. CONCLUSIONS: RB should be incorporated into non-simplified DBSs with caution, as it can interfere with their physical-mechanical properties, leading to a possible misinterpretation of bonded interface.


Asunto(s)
Recubrimientos Dentinarios/química , Dentina/efectos de los fármacos , Colorantes Fluorescentes/química , Rodaminas/química , Agua/química , Resinas Compuestas/química , Recubrimiento Dental Adhesivo/métodos , Fracaso de la Restauración Dental , Humanos , Ensayo de Materiales , Microscopía Confocal , Reproducibilidad de los Resultados , Cementos de Resina/química , Solubilidad , Propiedades de Superficie , Resistencia a la Tracción , Factores de Tiempo
10.
Braz Oral Res ; 29: 1-5, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25466328

RESUMEN

Laser irradiation after the immediate application of dentin bonding systems (DBSs) and prior to their polymerization has been proposed to increase bond strength. The objective of this study was to evaluate the effect of diode laser irradiation (λ = 970 nm) on simplified DBSs through microtensile bond strength tests. Forty healthy human molars were randomly distributed among four groups (n = 10) according to DBSs used [Adper™ SingleBond 2 (SB) and Adper™ EasyOne (EO)], and the respective groups were irradiated with a diode laser (SB-L and EO-L). After bonding procedures and composite resin build-ups, teeth were stored in deionized water for 7 days and then sectioned to obtain stick-shaped specimens (1.0 mm2). The microtensile test was performed at 0.5 mm/min, yielding bond strength values in MPa, which were evaluated by two-way ANOVA followed by Tukey's test (p < 0.05) for individual comparisons. For both adhesive systems, diode laser irradiation promoted significant increases in bond strength values (SB: 33.49 ± 6.77; SB-L: 43.69 ± 8.15; EO: 19.67 ± 5.86; EO-L: 29.87 ± 6.98). These results suggest that diode laser irradiation is a promising technique for achieving better performance of adhesive systems on dentin.


Asunto(s)
Cementos Dentales/química , Recubrimientos Dentinarios/química , Dentina/efectos de la radiación , Láseres de Semiconductores/uso terapéutico , Análisis de Varianza , Resinas Compuestas/química , Recubrimiento Dental Adhesivo/métodos , Humanos , Ensayo de Materiales , Ilustración Médica , Distribución Aleatoria , Valores de Referencia , Reproducibilidad de los Resultados , Propiedades de Superficie/efectos de los fármacos , Resistencia a la Tracción/efectos de la radiación , Factores de Tiempo
11.
Braz Oral Res ; 29: 1-5, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25466330

RESUMEN

Increased surface roughness and wear of resin cements may cause failure of indirect restorations. The aim of this study was to evaluate quantitatively the surface roughness change and the vertical wear of four resin cements subjected to mechanical toothbrushing abrasion. Ten rectangular specimens (15 × 5 × 4 mm) were fabricated according to manufacturer instructions for each group (n = 10): Nexus 3, Kerr (NX3); RelyX ARC, 3M ESPE (ARC); RelyX U100, 3M ESPE (U100); and Variolink II, Ivoclar/Vivadent (VL2). Initial roughness (Ra, µm) was obtained through 5 readings with a roughness meter. Specimens were then subjected to toothbrushing abrasion (100,000 cycles), and further evaluation was conducted for final roughness. Vertical wear (µm) was quantified by 3 readings of the real profile between control and brushed surfaces. Data were subjected to analysis of variance, followed by Tukey's test (p < 0.05). The Pearson correlation test was performed between the surface roughness change and wear (p < 0.05). The mean values of initial/final roughness (Ra, µm)/wear (µm) were as follows: NX3 (0.078/0.127/23.175); ARC (0.086/0.246/20.263); U100 (0.296/0.589/16.952); and VL2 (0.313/0.512/22.876). Toothbrushing abrasion increased surface roughness and wear of all resin cements tested, although no correlation was found between those variables. Vertical wear was similar among groups; however, it was considered high and may lead to gap formation in indirect restorations.


Asunto(s)
Alisadura de la Restauración Dental , Cementos de Resina/química , Abrasión de los Dientes , Cepillado Dental , Análisis de Varianza , Bisfenol A Glicidil Metacrilato/química , Ensayo de Materiales , Polietilenglicoles/química , Ácidos Polimetacrílicos/química , Valores de Referencia , Estadísticas no Paramétricas , Propiedades de Superficie , Factores de Tiempo
12.
Quintessence Int ; 45(7): 593-7, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24847498

RESUMEN

The evolution of adhesive procedures and ceramic systems has allowed for the placement of minimum thickness laminate veneers on unprepared teeth. A 20-year-old post-orthodontics male patient with multiple diastemas required restorative procedures. A multidisciplinary approach was performed, involving gingivectomy, in-office bleaching, and application of minimum thickness veneers. The immediate and 1-year followup results exceeded expectations; however, long-term clinical trials are necessary to evaluate the performance of this new type of indirect restoration.


Asunto(s)
Coronas con Frente Estético , Estética Dental , Adulto , Cerámica , Estudios de Seguimiento , Humanos , Masculino , Blanqueamiento de Dientes , Adulto Joven
13.
Braz. dent. j ; Braz. dent. j;30(6): 592-598, Nov.-Dec. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1055449

RESUMEN

Abstract This study aimed to evaluate the polymerization properties of bulk-fill materials (low and high-viscosity) by using high-intensity continuous light and intermittent photo-activation in terms of polymerization shrinkage stress and degree of conversion (DC). The following Bulk-fill and Conventional nanofilled resin composites were evaluated: Filtek Z350XT Flow (3M/ESPE), SureFil SDR Flow (Dentsply), Filtek Bulk Fill Flow (3M/ESPE), Filtek Z350XT (3M/ESPE) and Filtek Bulk Fill Posterior (3M/ESPE). A LED device (DB 685, Dabi Atlante) was used for both protocols: continuous uniform and intermittent photo-activation (light-on and light-off cycles) with identical radiant exposure (14 J/cm2). The polymerization shrinkage stress (n=6) was evaluated by inserting a single increment of 12 mm3 between two stainless steel plates (6×2 mm) adapted to a Universal Testing Machine (UTM), at different times. Measurements were recorded after photo-activation. The degree of conversion was evaluated by Fourier transformed infrared spectroscope (FTIR) with an attenuated total reflectance (ATR) accessory (n=5). Data were analyzed by three-way ANOVA and Tukey's HSD (α=0.05) tests. Bulk Fill Posterior presented higher shrinkage stress values when photo-activated with the intermittent technique (p<0.05). The intermittent photo-activation increased the degree of conversion for the low-viscosity bulk-fills (p<0.05). Therefore, the use of modulated photo-activation (intermittent) must be indicated with caution since its use can influence the shrinkage stress and degree of conversion of composites, which varies according to the resin formulations.


Resumo O presente estudo teve como objetivo avaliar as propriedades de polimerização de materiais bulk-fill (baixa e alta viscosidade) utilizando luz contínua de alta intensidade e fotoativação intermitente em relação ao estresse de contração de polimerização e grau de conversão (DC). As seguintes resinas compostas Bulk-fill e nanohíbridas convencionais foram avaliadas: Filtek Z350XT Flow (3M/ESPE), SureFil SDR Flow (Dentsply), Filtek Bulk Fill Flow (3M/ESPE), Filtek Z350XT (3M/ESPE) e Filtek Bulk Fill Posterior (3M/ESPE). Um dispositivo de LED (DB 685, Dabi Atlante) foi utilizado nos dois protocolos: fotoativação contínua e intermitente contínua (ciclos de liga e desliga) com exposição idêntica (14 J/cm2). A tensão de contração de polimerização (n=6) foi avaliada através da inserção de um incremento único de 12 mm3 entre duas placas de aço inoxidável (6×2 mm) adaptadas a uma Máquina de Ensaio Universal (UTM), em tempos diferentes. As medições foram registradas após a fotoativação. O grau de conversão foi avaliado por FTIR-ATR (n=5). Os dados foram analisados ​​pelos testes ANOVA a três fatores e teste de Tukey (α=0,05). A resina Bulk Fill Posterior apresentou maiores valores de tensão de contração quando fotoativadas com a técnica intermitente (p<0,05). A fotoativação intermitente aumentou o grau de conversão nas resinas bulk-fill de baixa viscosidade (p<0,05). Portanto, o uso de fotoativação modulada (intermitente) deve ser indicado com cautela, uma vez que seu uso pode influenciar a tensão de contração e o grau de conversão dos compósitos, o que varia de acordo com as formulações da resina.


Asunto(s)
Ensayo de Materiales , Resinas Compuestas , Viscosidad , Polimerizacion
14.
Braz Dent J ; 24(4): 326-9, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24173249

RESUMEN

The concern with the polymerization shrinkage of restorative resin composites also applies to resin cements. The aim of this study was to evaluate the influence of volume and polymerization mode on forces generated during polymerization shrinkage (FGPS) of resin cements. Two light-cured resin cements--Variolink II (VL; Ivoclar Vivadent) and Nexus 3 (NX; Kerr)--and two self-cured resin cements - Multilink (ML; Ivoclar Vivadent) and Cement Post (CP; Angelus) - were inserted between two rectangular steel bases (6x2 mm) with distance set at 0.1, 0.3 and 0.5 mm, establishing a variation of volume. These steel bases were attached to a universal test machine with 50 kg load cell and forces (N) were registered for 10 min. Values of maximum forces generated by each material were subjected to two-way ANOVA and Tukey's test for individual comparisons (α=0.05). VL, NX and CP developed increasing FGPS as the volume of material increased, while ML presented the opposite behavior. It may be concluded that higher volume increases FGPS even with a concomitant decrease of C-factor, unless the resin cements present lower force generation rates as a function of time in combination with a low C-factor, resulting in stress relief and consequently lower values of FGPS.


Asunto(s)
Polimerizacion , Cementos de Resina/química , Recubrimiento Dental Adhesivo
15.
J. appl. oral sci ; J. appl. oral sci;25(4): 381-386, July-Aug. 2017. tab, graf
Artículo en Inglés | LILACS, BBO | ID: biblio-893641

RESUMEN

Abstract Simplified dentin-bonding systems are clinically employed for most adhesive procedures, and they are prone to hydrolytic degradation. Objective This study aimed to investigate the effect of laser diode irradiation on the degree of conversion (DC), water sorption (WS), and water solubility (WSB) of these bonding systems in an attempt to improve their physico-mechanical resistance. Material and Methods Two bonding agents were tested: a two-step total-etch system [Adper™ Single Bond 2, 3M ESPE (SB)] and a universal system [Adper™ Single Bond Universal, 3M ESPE (SU)]. Square-shaped specimens were prepared and assigned into 4 groups (n=5): SB and SU (control groups - no laser irradiation) and SB-L and SU-L [SB and SU laser (L) - irradiated groups]. DC was assessed using Fourier transform infrared spectroscopy with attenuated total reflectance. Additional uncured resin samples (≈3.0 µL, n=5) of each adhesive were also scanned for final DC calculation. For WS/WSB tests, similar specimens (n=10) were prepared and measured by monitoring the mass changes after dehydration/water storage cycles. For both tests, adhesive fluids were dropped into standardized Teflon molds (6.0×6.0×1.0 mm), irradiated with a 970-nm laser diode, and then polymerized with an LED-curing unit (1 W/cm2). Results Laser irradiation immediately before photopolymerization increased the DC (%) of the tested adhesives: SB-L>SB>SU-L>SU. For WS/WSB (μg/mm3), only the dentin bonding system (DBS) was a significant factor (p<0.05): SB>SU. Conclusion Irradiation with a laser diode improved the degree of conversion of all tested simplified dentin bonding systems, with no impact on water sorption and solubility.


Asunto(s)
Recubrimientos Dentinarios/efectos de la radiación , Láseres de Semiconductores , Polimerizacion/efectos de la radiación , Valores de Referencia , Solubilidad/efectos de la radiación , Propiedades de Superficie/efectos de la radiación , Reproducibilidad de los Resultados , Recubrimientos Dentinarios/química , Espectroscopía Infrarroja por Transformada de Fourier , Estadísticas no Paramétricas , Cementos Dentales/efectos de la radiación , Cementos Dentales/química , Transición de Fase/efectos de la radiación , Curación por Luz de Adhesivos Dentales/métodos , Luces de Curación Dental , Procesos Fotoquímicos/efectos de la radiación
16.
Braz. dent. j ; Braz. dent. j;27(5): 532-536, Sept.-Oct. 2016. tab, graf
Artículo en Inglés | LILACS | ID: biblio-828038

RESUMEN

Abstract This in vitro study evaluated the effect of sodium bicarbonate and sodium ascorbate on the microtensile bond strength of an etch-and-rinse system to bleached bovine enamel. Sixty bovine enamel blocks (4x4 mm) were flattened and randomly allocated into 5 groups: G1 (negative control): without treatment; G2 (positive control): bleached with 35% hydrogen peroxide (HP); G3: bleached and stored for 7 days in artificial saliva before restorative procedures; G4: bleached and treated with 10% sodium bicarbonate solution for 5 min; G5: bleached and treated with 10% sodium ascorbate hydrogel for 15 min. HP gel was applied twice (20 min each, except in G1) and the adhesive restorations were performed. After 24 h, the specimens were sectioned into sticks and submitted to microtensile bond strength testing with a crosshead speed of 0.5 mm/min (n=12). As a complementary visual observation, the enamel surfaces of the G1 and G2 specimens were evaluated with scanning electron microscopy. Data were analyzed by one-way ANOVA (p<0.05). The means (standard deviation) were: G1: 24.22±7.74; G2: 18.29±5.88; G3: 40.88±7.95; G4: 19.95±5.67 and G5: 24.43±6.43. Adhesive failures were predominant in all groups. The comparison between the treatments indicates that waiting 7 days after bleaching is still the most effective approach. When this waiting period is not possible, application of sodium ascorbate or sodium bicarbonate seems to be a good alternative. Therefore, the practicality of obtaining sodium bicarbonate in the bleaching kits and its higher stability enables its clinical use.


Resumo Este estudo in vitro avaliou o efeito do bicarbonato de sódio e do ascorbato de sódio na resistência de união de um sistema adesivo convencional unido ao esmalte bovino clareado. Sessenta blocos de esmalte bovino (4x4 mm) foram planificados e distribuídos aleatoriamente em 5 grupos: G1: (controle negativo); G2 (controle positivo): clareamento com peróxido de hidrogênio 35% (HP); G3: clareamento com HP seguido de armazenamento por 7 dias em saliva artificial antes do procedimento restaurador; G4: clareamento com HP seguido de tratamento com a solução de bicarbonato de sódio 10% por 5 min; G5: clareamento com HP seguido de tratamento com hidrogel de ascorbato de sódio 10% por 15 min. O HP foi aplicado duas vezes (20 min cada, com exceção do grupo G1) e então as restaurações adesivas foram realizadas. Após 24 h, os espécimes foram seccionados em palitos e submetidos ao teste de resistência de união a uma velocidade de 0,5 mm/min (n=12). As superfícies de esmalte de G1 e G2 foram avaliadas com microscopia eletrônica de varredura para fins de análise visual complementar. Os dados foram analisados por ANOVA a um critério (p<0,05). As medias (desvio-padrão) foram: G1: 24,22±7,74; G2: 18,29±5,88; G3: 40,88±7,95; G4: 19,95±5,67 e G5: 24,43±6,43. Falhas adesivas foram predominantes em todos os grupos. A comparação entre os diferentes tratamentos indica que esperar 7 dias após o clareamento é ainda a abordagem mais eficaz. Nos casos em que este período de espera não é possível, a aplicação do ascorbato de sódio e do bicarbonate de sódio parecem ser boas alternativas. Entretanto, a praticidade na obtenção da solução de bicarbonato de sódio nos kits de clareamento e sua maior estabilidade favorecem o seu uso clínico.


Asunto(s)
Animales , Bovinos , Antioxidantes/farmacología , Esmalte Dental , Resistencia a la Tracción , Blanqueamiento de Dientes
17.
Rev. Salusvita (Online) ; 35(1): 119-127, 2016.
Artículo en Portugués | LILACS | ID: lil-788585

RESUMEN

Introdução: todo canal radicular instrumentado, seja por métodos manuais ou rotatórios, apresentará a formação de uma lama de detritos sobre a parede dentinária, sendo esta composta tanto por matéria orgânica quanto inorgânica, denominada de smear layer. Em relação a sua remoção ou manutenção das paredes do canal, diversos autores apresentaram opiniões e resultados divergentes, gerando dúvidas aos clínicos em relação à conduta mais adequada a ser empregada no tratamento endodôntico. Objetivo: este trabalho, por meio de uma revisão de literatura, visa fornecer uma resposta clara, capaz de melhorar o prognóstico do tratamento. Metodologia: para isso, foram utilizados 25 trabalhos desde o ano de 1975 a 2014, coletados por meio das bases de dados PubMed e Web of Science, com as palavras chaves: "smear layer", "smear layer removal", "smear layer permeability", "smear layer bacteria" e "smear layer sealing". Conclusão: baseado na metodologia proposta pode-se concluir que a remoção da smear layer é a melhor conduta a ser tomada durante o tratamento endodôntico, pois proporciona uma ação antimicrobiana mais eficiente das substâncias irrigadoras e medicações intracanais, além de permitir um melhor selamento entre dentina e material obturador, reduzindo as chances de uma infiltração.


Introduction: the root canal instrumentation, either by manual or mechanicals methods, will result in a formation of debris layer on dentin surface composted by organic and inorganic tissues, denominated smear layer. Due to the several divergent opinion about its removal or maintenance into the root canal, the clinicians may have a doubt for the most appropriate conduct to be performed in endodontics treatments. Objective: this article aimed collect the mains results obtained by different authors to provide a clear answer capable of improving the treatment prognosis. Methods: for this, were used 25 articles since 1975 to 2014 collected by date base PubMed and Web of Science with the keywords "smear layer", "smear layer removal", "smear layer permeability", "smear layer bacteria" and "smear layer sealing". Conclusion: based in the informations obtained in this review, its was concluded that the smear layer removal can, not only, improve the antimicrobial action of the irrigants agents and intracanal medicaments, but also provide a most efficient sealing of the fillingmaterial to dentine wall, reducing the chances to occur a leak in its interface.


Asunto(s)
Humanos , Masculino , Femenino , Capa de Barro Dentinario , Permeabilidad de la Dentina , Pronóstico , Endodoncia
18.
J. appl. oral sci ; J. appl. oral sci;24(4): 317-324, July-Aug. 2016. tab, graf
Artículo en Inglés | LILACS, BBO | ID: lil-792589

RESUMEN

ABSTRACT Objective This study investigated the effect of the fluorescent dye rhodamine B (RB) for interfacial micromorphology analysis of dental composite restorations on water sorption/solubility (WS/WSL) and microtensile bond strength to dentin (µTBS) of a 3-step total etch and a 2-step self-etch adhesive system. Material and Methods The adhesives Adper Scotchbond Multi-Purpose (MP) and Clearfil SE Bond (SE) were mixed with 0.1 mg/mL of RB. For the WS/WSL tests, cured resin disks (5.0 mm in diameter x 0.8 mm thick) were prepared and assigned into four groups (n=10): MP, MP-RB, SE, and SE-RB. For µTBS assessment, extracted human third molars (n=40) had the flat occlusal dentin prepared and assigned into the same experimental groups (n=10). After the bonding and restoration procedures, specimens were sectioned in rectangular beams, stored in water and tested after seven days or after 12 months. The failure mode of fractured specimens was qualitatively evaluated under optical microscope (x40). Data from WS/WSL and µTBS were assessed by one-way and three-way ANOVA, respectively, and Tukey’s test (α=5%). Results RB increased the WSL of MP and SE. On the other hand, WS of both MP and SE was not affected by the addition of RB. No significance in µTBS between MP and MP-RB for seven days or one year was observed, whereas for SE a decrease in the µTBS means occurred in both storage times. Conclusions RB should be incorporated into non-simplified DBSs with caution, as it can interfere with their physical-mechanical properties, leading to a possible misinterpretation of bonded interface.


Asunto(s)
Humanos , Rodaminas/química , Agua/química , Recubrimientos Dentinarios/química , Dentina/efectos de los fármacos , Colorantes Fluorescentes/química , Solubilidad , Propiedades de Superficie , Resistencia a la Tracción , Factores de Tiempo , Ensayo de Materiales , Reproducibilidad de los Resultados , Recubrimiento Dental Adhesivo/métodos , Microscopía Confocal , Resinas Compuestas/química , Cementos de Resina/química , Fracaso de la Restauración Dental
19.
Braz. oral res. (Online) ; 29(1): 1-5, 2015. tab, ilus
Artículo en Inglés | LILACS | ID: lil-777183

RESUMEN

Laser irradiation after the immediate application of dentin bonding systems (DBSs) and prior to their polymerization has been proposed to increase bond strength. The objective of this study was to evaluate the effect of diode laser irradiation (λ = 970 nm) on simplified DBSs through microtensile bond strength tests. Forty healthy human molars were randomly distributed among four groups (n = 10) according to DBSs used [Adper™ SingleBond 2 (SB) and Adper™ EasyOne (EO)], and the respective groups were irradiated with a diode laser (SB-L and EO-L). After bonding procedures and composite resin build-ups, teeth were stored in deionized water for 7 days and then sectioned to obtain stick-shaped specimens (1.0 mm2). The microtensile test was performed at 0.5 mm/min, yielding bond strength values in MPa, which were evaluated by two-way ANOVA followed by Tukey’s test (p < 0.05) for individual comparisons. For both adhesive systems, diode laser irradiation promoted significant increases in bond strength values (SB: 33.49 ± 6.77; SB-L: 43.69 ± 8.15; EO: 19.67 ± 5.86; EO-L: 29.87 ± 6.98). These results suggest that diode laser irradiation is a promising technique for achieving better performance of adhesive systems on dentin.


Asunto(s)
Humanos , Cementos Dentales/química , Recubrimientos Dentinarios/química , Dentina/efectos de la radiación , Láseres de Semiconductores/uso terapéutico , Análisis de Varianza , Resinas Compuestas/química , Recubrimiento Dental Adhesivo/métodos , Ensayo de Materiales , Ilustración Médica , Distribución Aleatoria , Valores de Referencia , Reproducibilidad de los Resultados , Propiedades de Superficie/efectos de los fármacos , Factores de Tiempo , Resistencia a la Tracción/efectos de la radiación
20.
Braz. oral res. (Online) ; 29(1): 1-5, 2015. tab, ilus
Artículo en Inglés | LILACS | ID: lil-777244

RESUMEN

Increased surface roughness and wear of resin cements may cause failure of indirect restorations. The aim of this study was to evaluate quantitatively the surface roughness change and the vertical wear of four resin cements subjected to mechanical toothbrushing abrasion. Ten rectangular specimens (15 × 5 × 4 mm) were fabricated according to manufacturer instructions for each group (n = 10): Nexus 3, Kerr (NX3); RelyX ARC, 3M ESPE (ARC); RelyX U100, 3M ESPE (U100); and Variolink II, Ivoclar/Vivadent (VL2). Initial roughness (Ra, µm) was obtained through 5 readings with a roughness meter. Specimens were then subjected to toothbrushing abrasion (100,000 cycles), and further evaluation was conducted for final roughness. Vertical wear (µm) was quantified by 3 readings of the real profile between control and brushed surfaces. Data were subjected to analysis of variance, followed by Tukey’s test (p < 0.05). The Pearson correlation test was performed between the surface roughness change and wear (p < 0.05). The mean values of initial/final roughness (Ra, µm)/wear (µm) were as follows: NX3 (0.078/0.127/23.175); ARC (0.086/0.246/20.263); U100 (0.296/0.589/16.952); and VL2 (0.313/0.512/22.876). Toothbrushing abrasion increased surface roughness and wear of all resin cements tested, although no correlation was found between those variables. Vertical wear was similar among groups; however, it was considered high and may lead to gap formation in indirect restorations.


Asunto(s)
Alisadura de la Restauración Dental , Cementos de Resina/química , Abrasión de los Dientes , Cepillado Dental , Análisis de Varianza , Bisfenol A Glicidil Metacrilato/química , Ensayo de Materiales , Polietilenglicoles/química , Ácidos Polimetacrílicos/química , Valores de Referencia , Estadísticas no Paramétricas , Propiedades de Superficie , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA