Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Dis Esophagus ; 34(3)2021 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-32944737

RESUMEN

The ReBus cohort is a matched nested case-control cohort of patients with nondysplastic (ND) Barrett's esophagus (BE) at baseline who progressed (progressors) or did not progress (nonprogressors) to high-grade dysplasia (HGD) or cancer. This cohort is constructed using the most stringent inclusion criteria to optimize explorative studies on biomarkers predicting malignant progression in NDBE. These explorative studies may benefit from expanding the number of cases and by incorporating samples that allow assessment of the biomarker over space (spatial variability) and over time (temporal variability). To (i) update the ReBus cohort by identifying new progressors and (ii) identify progressors and nonprogressors within the updated ReBus cohort containing spatial and temporal information. The ReBus cohort was updated by identifying Barrett's patients referred for endoscopic work-up of neoplasia at 4 tertiary referral centers. Progressors and nonprogressors with a multilevel (spatial) endoscopy and additional prior (temporal) endoscopies were identified to evaluate biomarkers over space and over time. The original ReBus cohort consisted of 165 progressors and 723 nonprogressors. We identified 65 new progressors meeting the same strict selection criteria, resulting in a total number of 230 progressors and 723 matched nonprogressors in the updated ReBus cohort. Within the updated cohort, 61 progressors and 107 nonprogressors (mean age 61 ± 10 years) with a spatial endoscopy (median level 3 [2-4]) were identified. 33/61 progressors and 50/107 nonprogressors had a median of 3 (2-4) additional temporal endoscopies. Our updated ReBus cohort consists of 230 progressors and 723 matched nonprogressors using the most strict selection criteria. In a subgroup of 168 Barrett's patients (the SpaTemp cohort), multiple levels have been sampled at baseline and during follow-up providing a unique platform to study spatial and temporal distribution of biomarkers in BE.


Asunto(s)
Adenocarcinoma , Esófago de Barrett , Neoplasias Esofágicas , Biomarcadores , Progresión de la Enfermedad , Neoplasias Esofágicas/diagnóstico , Humanos , Recién Nacido
2.
Gut ; 66(3): 438-445, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-26674360

RESUMEN

BACKGROUND AND AIMS: Colonoscopy is the current reference standard for the detection of colorectal neoplasia, but nevertheless adenomas remain undetected. The Endocuff, an endoscopic cap with plastic projections, may improve colonic visualisation and adenoma detection. The aim of this study was to compare the mean number of adenomas per patient (MAP) and the adenoma detection rate (ADR) between Endocuff-assisted colonoscopy (EAC) and conventional colonoscopy (CC). METHODS: We performed a multicentre, randomised controlled trial in five hospitals and included fecal immonochemical test (FIT)-positive screening participants as well as symptomatic patients (>45 years). Consenting patients were randomised 1:1 to EAC or CC. All colonoscopies were performed by experienced colonoscopists (≥500 colonoscopies) who were trained in EAC. All colonoscopy quality indicators were prospectively recorded. FINDINGS: Of the 1063 included patients (52% male, median age 65 years), 530 were allocated to EAC and 533 to CC. More adenomas were detected with EAC, 722 vs 621, but the gain in MAP was not significant: on average 1.36 per patient in the EAC group versus 1.17 in the CC group (p=0.08). In a per-protocol analysis, the gain was 1.44 vs 1.19 (p=0.02), respectively. In the EAC group, 275 patients (52%) had one or more adenomas detected versus 278 in the CC group (52%; p=0.92). For advanced adenomas these numbers were 109 (21%) vs 117 (22%). The adjusted caecal intubation rate was lower with EAC (94% vs 99%; p<0.001), however when allowing crossover from EAC to CC, they were similar in both groups (98% vs 99%; p value=0.25). INTERPRETATION: Though more adenomas are detected with EAC, the routine use of Endocuff does not translate in a higher number of patients with one or more adenomas detected. Whether increased detection ultimately results in a lower rate of interval carcinomas is not yet known. TRIAL REGISTRATION NUMBER: http://www.trialregister.nl Dutch Trial Register: NTR3962.


Asunto(s)
Adenoma/diagnóstico , Neoplasias del Colon/diagnóstico , Colonoscopía/instrumentación , Centros Médicos Académicos/estadística & datos numéricos , Anciano , Competencia Clínica , Colonoscopía/efectos adversos , Heces/química , Femenino , Humanos , Inmunoquímica , Masculino , Persona de Mediana Edad
3.
Lancet Digit Health ; 5(12): e905-e916, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-38000874

RESUMEN

BACKGROUND: Computer-aided detection (CADe) systems could assist endoscopists in detecting early neoplasia in Barrett's oesophagus, which could be difficult to detect in endoscopic images. The aim of this study was to develop, test, and benchmark a CADe system for early neoplasia in Barrett's oesophagus. METHODS: The CADe system was first pretrained with ImageNet followed by domain-specific pretraining with GastroNet. We trained the CADe system on a dataset of 14 046 images (2506 patients) of confirmed Barrett's oesophagus neoplasia and non-dysplastic Barrett's oesophagus from 15 centres. Neoplasia was delineated by 14 Barrett's oesophagus experts for all datasets. We tested the performance of the CADe system on two independent test sets. The all-comers test set comprised 327 (73 patients) non-dysplastic Barrett's oesophagus images, 82 (46 patients) neoplastic images, 180 (66 of the same patients) non-dysplastic Barrett's oesophagus videos, and 71 (45 of the same patients) neoplastic videos. The benchmarking test set comprised 100 (50 patients) neoplastic images, 300 (125 patients) non-dysplastic images, 47 (47 of the same patients) neoplastic videos, and 141 (82 of the same patients) non-dysplastic videos, and was enriched with subtle neoplasia cases. The benchmarking test set was evaluated by 112 endoscopists from six countries (first without CADe and, after 6 weeks, with CADe) and by 28 external international Barrett's oesophagus experts. The primary outcome was the sensitivity of Barrett's neoplasia detection by general endoscopists without CADe assistance versus with CADe assistance on the benchmarking test set. We compared sensitivity using a mixed-effects logistic regression model with conditional odds ratios (ORs; likelihood profile 95% CIs). FINDINGS: Sensitivity for neoplasia detection among endoscopists increased from 74% to 88% with CADe assistance (OR 2·04; 95% CI 1·73-2·42; p<0·0001 for images and from 67% to 79% [2·35; 1·90-2·94; p<0·0001] for video) without compromising specificity (from 89% to 90% [1·07; 0·96-1·19; p=0·20] for images and from 96% to 94% [0·94; 0·79-1·11; ] for video; p=0·46). In the all-comers test set, CADe detected neoplastic lesions in 95% (88-98) of images and 97% (90-99) of videos. In the benchmarking test set, the CADe system was superior to endoscopists in detecting neoplasia (90% vs 74% [OR 3·75; 95% CI 1·93-8·05; p=0·0002] for images and 91% vs 67% [11·68; 3·85-47·53; p<0·0001] for video) and non-inferior to Barrett's oesophagus experts (90% vs 87% [OR 1·74; 95% CI 0·83-3·65] for images and 91% vs 86% [2·94; 0·99-11·40] for video). INTERPRETATION: CADe outperformed endoscopists in detecting Barrett's oesophagus neoplasia and, when used as an assistive tool, it improved their detection rate. CADe detected virtually all neoplasia in a test set of consecutive cases. FUNDING: Olympus.


Asunto(s)
Esófago de Barrett , Aprendizaje Profundo , Neoplasias Esofágicas , Humanos , Esófago de Barrett/diagnóstico , Neoplasias Esofágicas/diagnóstico , Neoplasias Esofágicas/patología , Esofagoscopía/métodos , Oportunidad Relativa
4.
Endoscopy ; 40(10): 799-805, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18828075

RESUMEN

BACKGROUND AND STUDY AIMS: We have recently proposed a classification of mucosal morphology in Barrett's esophagus based on three criteria: regularity of mucosal pattern, regularity of vascular pattern, and presence of abnormal blood vessels. We aimed to evaluate the interobserver agreement with the proposed mucosal morphology classification and to assess the additional value of narrow band imaging (NBI) over high resolution white light endoscopy (HR-WLE). PATIENTS AND METHODS: Five international experts in the field of Barrett's imaging and seven community endoscopists with no expertise in this field independently evaluated magnified still images from 50 areas, obtained with HR-WLE and NBI, in Barrett's esophagus patients. Visual analogue scales (VAS) were used for scoring imaging quality. Interobserver agreement for mucosal morphology and yield for identifying early neoplasia were assessed. RESULTS: Imaging qualities of NBI were rated more highly than HR-WLE, when evaluated separately as well as in a side-by-side comparison. The interobserver agreement ranged from 0.40 to 0.56 and did not significantly differ between expert and non-expert endoscopists. The overall yield for correctly identifying images of early neoplasia was 81 % for HR-WLE, 72 % for NBI and 83 % for HR-WLE + NBI, with no significant difference between experts and non-experts. CONCLUSION: Interobserver agreement for the classification of mucosal morphology was moderate. Although NBI was rated more highly than HR-WLE for imaging quality, this did not result in improved interobserver agreement or increased yield for identifying early neoplasia in Barrett's esophagus. This applied to non-expert as well as expert endoscopists.


Asunto(s)
Esófago de Barrett/patología , Carcinoma/patología , Endoscopía , Neoplasias Esofágicas/patología , Membrana Mucosa/patología , Lesiones Precancerosas/patología , Esófago de Barrett/clasificación , Competencia Clínica , Humanos , Aumento de la Imagen , Luz , Microscopía , Membrana Mucosa/irrigación sanguínea , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos
5.
World J Gastroenterol ; 12(2): 292-7, 2006 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-16482632

RESUMEN

AIM: To investigate the correlation between ASCA and presence of mucosal S. cerevisiae DNA in a population of CD, ulcerative colitis (UC) patients and controls. METHODS: S. cerevisiae-specific primers and a fluorescent probe were designed for a 5' exonuclease real time PCR (TaqMan) assay, which is a homogenous system using a fluorescent-labelled probe for the detection of PCR product in real time. We analyzed the relation of the PCR results with the ASCA findings in a group of 76 inflammatory bowel disease (IBD) patients (31 CD, 45 UC) and 22 healthy controls (HC). RESULTS: ASCA (IgA or IgG) were positive in 19 (61%) patients with CD, 12 (27%) with UC and none of the HC. PCR amplification was inhibited and excluded from the final results in 10 (22%) UC patients, 7 (22%) CD patients, and 6 (30%) HC. In only 15 of the mucosal samples, S. cerevisiae DNA was detected by real time PCR, including 7 (29%) in CD, 7 (19%) in UC, 1 (6%) in HC. In 4 CD and in 4 UC patients, ASCA and mucosal S. cerevisiae were positive. Mucosal S. cerevisiae was present in combination with negative ASCA IgA and IgG in 3 UC, and 3 CD patients. CONCLUSION: We conclude that since the presence of S. cerevisiae in colonic mucosal biopsy specimens is very rare, ASCA is unlikely to be explained by continuous exposure to S. cerevisiae in the mucosa. Therefore, ASCA formation must occur earlier in life and levels remain relatively stable thereafter in immunological susceptible persons.


Asunto(s)
Anticuerpos Antifúngicos/sangre , ADN de Hongos/análisis , Enfermedades Inflamatorias del Intestino/microbiología , Mucosa Intestinal/microbiología , Saccharomyces cerevisiae/inmunología , Humanos , Mucosa Intestinal/metabolismo , Permeabilidad , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Saccharomyces cerevisiae/genética
6.
Cancer Epidemiol ; 39(3): 388-93, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25910865

RESUMEN

BACKGROUND: The effectiveness of colorectal cancer screening programs based on the fecal immunochemical test (FIT) is influenced by program adherence during consecutive screening rounds. We aimed to evaluate the participation rate, yield, and interval cancers in a third round of biennial CRC screening using FIT and to compare those with the first and the second screening round. METHODS: A total of 3566 average-risk individuals aged 50-75 years were invited to participate in a third round of biennial FIT-based CRC screening. All FIT positives were recommended to undergo colonoscopy. We merged our data with the national cancer registry in the Netherlands to identify all non-screen-detected cancers in our cohort. RESULTS: Of the invitees, 2142 (60%) returned the FIT in this third screening round, compared to 56% in the second round and 57% in the first round. Overall, 153 of the third-round participants (7.1%) had a positive FIT result, versus 7.9% in the second round and 8.1% in the first round (P=0.05). Of all FIT positives, 123 (80%) underwent colonoscopy. Within this group, 33 persons had advanced neoplasia. The predictive value of FIT positivity for advanced neoplasia was 27% (33/123), compared to 42% in the second round and 54% in the first round - a significant decline (P<0.01). CONCLUSION: In an FIT-based screening program, participation rates remained stable over consecutive biennial screening rounds, while the FIT positivity rate and positive predictive value for advanced neoplasia gradually declined. Cancers in non-participants are significantly more advanced in staging than cancers in participants in the first round of screening.


Asunto(s)
Carcinoma/diagnóstico , Neoplasias Colorrectales/diagnóstico , Detección Precoz del Cáncer/métodos , Detección Precoz del Cáncer/estadística & datos numéricos , Heces/química , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Países Bajos , Sangre Oculta , Sensibilidad y Especificidad
7.
Dig Liver Dis ; 36(1): 29-34, 2004 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-14971813

RESUMEN

BACKGROUND AND AIMS: Both genetic and microbial factors seem to play a pivotal role in the aetiopathogenesis of Crohn's disease. The CARD15 frameshift mutation might link host genetic factors and the indigenous microbial flora, since CARD15 expression is stimulated by peptidoglycan, thereby activating NF-kappaB. It is hypothesised that CARD15 mutation carriers have defective anti-microbial reactions, resulting in more penetrating lesions and antibody responses, which are now being used as highly specific markers for Crohn's disease. The serological marker anti-Saccharomyces cerevisiae antibody directed against cell wall oligomannosidic epitopes has high specificity for Crohn's disease. Perinuclear anti-neutrophil cytoplasmic antibodies have been found in a subgroup of Crohn's disease patients, mostly with colonic involvement. METHODS: We investigated the incidence of two CARD15 mutations (3020insC and 2722G>C), anti-S. cerevisiae antibody, and perinuclear anti-neutrophil cytoplasmic antibody in 108 (73F/35M) patients with Crohn's disease with a mean duration of disease since diagnosis of 16 (1-41) years in relation to their phenotype, according to the Vienna classification. RESULTS: The prevalence of CARD15 frameshift mutation was 21%. Of all patients, 62% were anti-S. cerevisiae antibody positive, and 9% had perinuclear anti-neutrophil cytoplasmic antibodies. The prevalence of both anti-S. cerevisiae antibodies and perinuclear anti-neutrophil cytoplasmic antibodies was higher in the mutation carriers compared to non-carriers. Remarkably, all patients with a CARD15 mutation and positive anti-S. cerevisiae antibody had ileal disease. Carriership of the mutation was significantly associated with penetrating behaviour of the disease and weakly associated with stricturing behaviour. Furthermore, anti-S. cerevisiae antibody was associated with ileal disease involvement. Finally, most perinuclear anti-neutrophil cytoplasmic antibody positive patients showed ulcerative-like behaviour of disease (by means of colonic localisation). CONCLUSIONS: Genetic and serologic markers might be useful in defining patient subgroups. This may result in a more accurate prediction of disease behaviour, prognosis and therapeutic approach.


Asunto(s)
Anticuerpos Anticitoplasma de Neutrófilos/inmunología , Anticuerpos Antifúngicos/sangre , Enfermedad de Crohn/genética , Saccharomyces cerevisiae/inmunología , Adulto , Anciano , Anciano de 80 o más Años , Enfermedad de Crohn/clasificación , Enfermedad de Crohn/diagnóstico , Enfermedad de Crohn/microbiología , Femenino , Mutación del Sistema de Lectura , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Fenotipo , Polimorfismo Genético , Estudios Seroepidemiológicos , Pruebas Serológicas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA