Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Dig Dis Sci ; 67(1): 282-292, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-33515378

RESUMEN

BACKGROUND: Misdiagnosed sessile serrated lesions (SSLs) are important precursors for interval colorectal cancers. AIMS: We investigated the usage of acetic acid (AA) solution for improving the detection of SSLs in the right colon in a randomized controlled trial. METHODS: A tandem observation of the right colon was performed in 412 consecutive patients. A first inspection was performed under white light high-definition endoscopy. In the AA group, a low concentration vinegar solution (AA: 0.005%) irrigated by a water pump in the right colon was compared with a plain solution of normal saline (NS) in the diagnostic yield of SSLs during the second inspection. Secondary outcomes in overall polyp detection were measured. RESULTS: Qualitative comparisons showed significant differences in the detection rates of all polyps except adenomas, with remarkable improvement in the demonstration of advanced (> 20 mm), SSLs, and hyperplastic polyps during the second inspection of the right colon using the AA solution. Significant improvement was also noted in the AA group, as far as the mean number of polyps/patient detected, not only in SSLs (AA group: 0.14 vs. NS group: 0.01, P < 0.001), but also in all histological types and all size-categories in the right colon. Small (≤ 9 mm) polyps were detected at a higher rate in the sigmoid colon expanding the effect of the method in the rest of the colon. CONCLUSION: AA-assisted colonoscopy led to a significant increase in SSLs detection rate in the right colon in a safe, quick, and effective manner.


Asunto(s)
Ácido Acético/uso terapéutico , Adenoma , Pólipos del Colon , Colonoscopía/métodos , Neoplasias Colorrectales , Irrigación Terapéutica/métodos , Adenoma/diagnóstico por imagen , Adenoma/patología , Colon Ascendente/diagnóstico por imagen , Pólipos del Colon/diagnóstico por imagen , Pólipos del Colon/patología , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/patología , Errores Diagnósticos/prevención & control , Detección Precoz del Cáncer/métodos , Femenino , Humanos , Indicadores y Reactivos/uso terapéutico , Masculino , Persona de Mediana Edad , Soluciones Farmacéuticas/uso terapéutico , Mejoramiento de la Calidad
3.
Ann Gastroenterol ; 35(4): 400-406, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35784628

RESUMEN

Background: Few data are available on the influence of colonoscope type on the training process and quality of colonoscopy. We conducted this prospective observational cohort study to investigate scope suitability for starting colonoscopy training, in relation to technical competence, quality indicators, and the patient's comfort during diagnostic colonoscopy. Methods: A total of 126 consecutive patients were enrolled in the study and assigned to one of 3 groups: adult colonoscope ([AC], n=41); intermediate pediatric colonoscope ([IPC], n=43); and long pediatric colonoscope ([LPC], n=42). Primary outcomes were completeness of the examination and minutes to the cecum. Secondary outcomes included patient tolerance, position change, use of abdominal compression, loop formation, kind of loop, and overall difficulty of the procedure. Results: Cecal intubation rates were not statistically different between the groups: AC/87.8%; IPC/81.4%; and LPC/92.8%. Terminal ileal intubation rate differed significantly among the 3 groups (P=0.015) with LPC having the higher rate (66.7% vs. 60.9%/AC and 37.2%/IPC). There were significant differences in positional changes (fewer with LPC/1.36 vs. AC/2.15 and IPC/2.09, P=0.027) and midazolam administered doses (lower with LPC/0.52 vs. AC/1.07 and IPC/0.93, P=0.032). Loop formation with subsequent resolution was significantly associated with more pain for the patient with all of the 3 colonoscope types. Conclusions: The LPC performs better in trainee hands than AC and IPC in terms of reaching competency, and quality indicators show less discomfort for the patients during colonoscopic procedures (lower midazolam dose and fewer positional changes). It could be considered the most suitable scope for starting high-quality colonoscopy training.

4.
Endosc Int Open ; 6(3): E308-E312, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29507871

RESUMEN

Background and study aims We describe a case of perforation after colonic endoscopic mucosal resection (EMR) that was treated conservatively. We would like to highlight the importance of decision-making mainly based on the endoscopist's point of view in combination with the surgical consultation. Although the radiological imaging is always needed, it cannot solely lead to a decision for operation. Intraperitoneal gas in computed tomography is not always associated with a hole in the endoscopic field and could be possibly explained from a "balloon" phenomenon. The amount of extraluminal air after an EMR does not correlate reciprocally with patient's pain after the procedure. Even though perforation is a radiological diagnosis and endoscopists should be aware of the common post-EMR radiological findings, the surgical examination is mandatory and should be coupled with the endoscopic opinion in order to guide appropriately the treatment in patients with acute pain.

5.
Ann Gastroenterol ; 28(1): 141-143, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25609218

RESUMEN

BACKGROUND: Most colonoscopic complications are polypectomy-related and occur more frequently during the removal of numerous small polyps. Therefore, it is important to have the best polypectomy approach of small polyps. The aim of the present animal study was to investigate the effectiveness and safety of cold snare polypectomy (CSP) technique combined with light pull of the snare in order to peel the mucosal and upper submucosal layer, namely pull CSP (PCSP), for the removal of polyps sized up to 12 mm in porcine models. METHODS: We performed a series of polypectomies in the pig colon with a double-channel experimental gastroscope using PCSP technique. RESULTS: Thirty cases of "polyps" larger than 7 mm and up to 12 mm were treated using PCSP technique. No sign of perforation or bleeding was observed in all cases performed with PCSP. CONCLUSIONS: According to our preliminary results in this animal model, PCSP could be a safe and effective technique for flat colonic polyp removal up to 12 mm in size consistent with the basic polypectomy principles.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA