Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Medicina (Kaunas) ; 60(1)2024 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-38256411

RESUMEN

Background and Objectives: Left atrial (LA) remodelling and dilatation predicts atrial fibrillation (AF) recurrences after catheter ablation. However, whether right atrial (RA) remodelling and dilatation predicts AF recurrences after ablation has not been fully evaluated. Materials and Methods: This is an observational study of 85 consecutive patients (aged 57 ± 9 years; 70 [82%] men) who underwent cardiac magnetic resonance before first catheter ablation for AF (40 [47.1%] persistent AF). Four-chamber cine-sequence was selected to measure LA and RA area, and ventricular end-systolic image phase to obtain atrial 3D volumes. The effect of different variables on event-free survival was investigated using the Cox proportional hazards model. Results: In patients with persistent AF, combined LA and RA area indexed to body surface area (AILA + RA) predicted AF recurrences (HR = 1.08, 95% CI 1.00-1.17, p = 0.048). An AILA + RA cut-off value of 26.7 cm2/m2 had 72% sensitivity and 73% specificity for predicting recurrences in patients with persistent AF. In this group, 65% of patients with AILA + RA > 26.7 cm2/m2 experienced AF recurrence within 2 years of follow-up (median follow-up 11 months), compared to 25% of patients with AILA + RA ≤ 26.7 cm2/m2 (HR 4.28, 95% CI 1.50-12.22; p = 0.007). Indices of LA and RA dilatation did not predict AF recurrences in patients with paroxysmal AF. Atrial 3D volumes did not predict AF recurrences after ablation. Conclusions: In this pilot study, the simple measurement of AILA + RA may predict recurrences after ablation of persistent AF, and may outperform measurements of atrial volumes. In paroxysmal AF, atrial dilatation did not predict recurrences. Further studies on the role of RA and LA remodelling are needed.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Masculino , Humanos , Femenino , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Proyectos Piloto , Atrios Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos
2.
J Electrocardiol ; 68: 150-152, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34455113

RESUMEN

We present an artefactual ECG created by a digital ECG-recording machine, caused by deletion of the first 80 ms of the QRS complex immediately following the pacing spike in a patient with complete atrio-ventricular block, biventricular pacing and chronic atrial fibrillation. The artefact was mistaken for inferior ST elevation myocardial infarction and the patient underwent unnecessary urgent coronary angiogram. We are not aware of this particular artefact pattern being previously reported in the literature.


Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Infarto del Miocardio con Elevación del ST , Fibrilación Atrial/diagnóstico , Electrocardiografía , Ventrículos Cardíacos , Humanos , Infarto del Miocardio con Elevación del ST/diagnóstico
3.
Europace ; 21(5): 724-731, 2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-30649273

RESUMEN

AIMS: Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) may define left atrial (LA) anatomy and structural remodelling, and facilitate atrial fibrillation (AF) ablation. We aimed to assess the intra- and inter-observer reproducibility and agreement of LGE-CMR parameters with direct application to AF ablation techniques. METHODS AND RESULTS: One experienced and one non-experienced observer performed complete LGE-CMR data analysis twice, on different days, in 40 randomly selected LGE-CMR examinations [20 performed before ablation (pre-ablation) and 20 performed 3 months after ablation (post-ablation)]. Four additional observers (two experienced and two non-experienced) performed complete LGE-CMR data analysis in a subgroup of 30 patients (15 pre-ablation and 15 post-ablation). All LGE-CMR were performed in sinus rhythm. Intra- and inter-observer reproducibility of LA volume, LA area, and sphericity index (SI) was high: coefficient of variation <10% and intraclass correlation coefficient >0.71. Geometric congruency of repeated reconstruction of LA shape was high: maximal error <5 mm for intra-observer and <8 mm for inter-observer. The precision of scar location increased with extent of scar, and was high (Dice coefficient >0.75) when the scar area was >5 cm2 for a single observer and >15 cm2 for multiple observers. Non-experienced observers performed equally well to experienced observers. CONCLUSION: Late gadolinium enhancement cardiac magnetic resonance measurements of LA area, volume, and SI were reproducible, and geometric congruency of LA shape was high. Location of scar was precise for scar areas >5 cm2 for single observers and >15 cm2 for multiple observers, regardless of the observers' experience. These results may serve as a reference for future studies on the role for substrate-based AF ablation procedures.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter/métodos , Gadolinio/farmacología , Atrios Cardíacos , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Fibrilación Atrial/patología , Fibrilación Atrial/cirugía , Remodelación Atrial , Medios de Contraste/farmacología , Femenino , Fibrosis , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/patología , Humanos , Masculino , Persona de Mediana Edad , Cuidados Preoperatorios/métodos , Reproducibilidad de los Resultados
4.
J Electrocardiol ; 57: 77-80, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31518910

RESUMEN

We report a case of ST segment elevation and PR depression in inferolateral leads in a patient with small bowel occlusion and gastric distension that disappeared immediately after gastric evacuation. Contrary to prior reports, we believe that these ECG changes do not represent an intrinsic cardiac electrical abnormality, but are likely artefactual. We hypothesise that the accumulated air between the heart, lower limbs and left precordial electrodes result in a significant departure from the simplified assumptions of standard 12 lead ECG analysis (that the electrical activity of the heart can be described by an electrical dipole at a fixed location in an electrical homogeneous sphere) in such a way that the ECG filtering process will not compensate for this bias and will artificially create the ECG pattern described in this report.


Asunto(s)
Infarto del Miocardio , Infarto del Miocardio con Elevación del ST , Arritmias Cardíacas , Electrocardiografía , Electrodos , Humanos
6.
Eur Heart J ; 36(46): 3268-75, 2015 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-26371113

RESUMEN

AIM: To assess clinical outcomes, efficacy, and safety according to sex during anticoagulation with apixaban compared with warfarin in patients with atrial fibrillation. METHODS AND RESULTS: Apixaban for Reduction in Stroke and Other Thromboembolic Events in Atrial Fibrillation (ARISTOTLE) was a randomized, double-blind, placebo-controlled, multicentre trial that included 11 785 (64.7%) men and 6416 (35.3%) women with atrial fibrillation or flutter randomized to receive either warfarin or apixaban. The primary efficacy endpoint was stroke or systemic embolism; secondary efficacy endpoints were death from any cause and cardiovascular death. The primary safety endpoint was major bleeding; secondary safety endpoints were a composite of major bleeding and non-major clinically relevant bleeding. The risk of stroke or systemic embolism was similar in women vs. men [adjusted hazard ratio (adjHR): 0.91; 95% confidence interval (CI): 0.74-1.12; P = 0.38]. However, among patients with history of stroke or transient ischaemic attack, women had a lower risk of recurrent stroke compared with men (adjHR: 0.70; 95% CI: 0.50-0.97; P = 0.036). Women also had a lower risk of all-cause death (adjHR: 0.63; 95% CI: 0.55-0.73; P < 0.0001) and cardiovascular death (adjHR: 0.62; 95% CI: 0.51-0.75; P < 0.0001), and a trend towards less major bleeding (adjHR: 0.86; 95% CI: 0.74-1.01; P = 0.066) and major or non-major clinically relevant bleeding (adjHR: 0.89; 95% CI: 0.80-1.00; P = 0.049). The efficacy and safety benefits of apixaban compared with warfarin were consistent regardless of sex. CONCLUSION: In the ARISTOTLE trial, women had a similar rate of stroke or systemic embolism but a lower risk of mortality and less clinically relevant bleeding than men. The efficacy and safety benefits of apixaban compared with warfarin were consistent in men and women. TRIAL REGISTRATION: ARISTOTLE ClinicalTrials.gov number, NCT00412984.


Asunto(s)
Anticoagulantes/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Pirazoles/uso terapéutico , Piridonas/uso terapéutico , Warfarina/uso terapéutico , Adulto , Distribución por Edad , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/mortalidad , Método Doble Ciego , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Factores de Riesgo , Distribución por Sexo , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
7.
Artículo en Inglés | MEDLINE | ID: mdl-38604832

RESUMEN

BACKGROUND: The impact of new-onset left bundle branch block (N-LBBB) developing after Transcatheter Aortic Valve Replacement (TAVR) on cardiac function and mechanical dyssynchrony is not well defined. METHODS: We retrospectively screened all patients who underwent TAVR in our centre between Oct 2018 and Sept 2021 (n = 409). We identified 38 patients with N-LBBB post-operatively (of which 28 were persistent and 10 were transient), and 17 patients with chronic pre-existent LBBB (C-LBBB). We excluded patients requiring pacing post TAVR. For all groups, we retrospectively analysed stored echocardiograms at 3 time points: before TAVR (T0), early after TAVR (T1, 1.2 ± 1.1 days), and late follow-up (T2, 1.5 ± 0.8 years), comparing LV mass and volumes, indices of LV function (LV ejection fraction, LVEF; global longitudinal strain, GLS), and mechanical dyssynchrony indices (systolic stretch index, severity of septal flash). RESULTS: At baseline (T0), C-LBBB had worse cardiac function, and larger LV volumes and LV mass, compared with patients with N-LBBB. At T1, N-LBBB resulted in mild dyssynchrony and decreased LVEF and GLS. Dyssynchrony progressed at T2 in persistent N-LBBB but not C-LBBB. In both groups however, LVEF remained stable at T2, although individual response was variable. Patients with better LVEF at baseline demonstrated a higher proportion of developing LBBB-induced LV dysfunction at T2. Lack of improvement of LVEF immediately after TAVR predicted deteriorating LVEF at T2. In transient LBBB, cardiac function and most dyssynchrony indices returned to baseline. CONCLUSIONS: N-LBBB after TAVR results in an immediate reduction of cardiac function, in spite of only mild dyssynchrony. When LBBB persists, patients with better cardiac function before TAVR are more likely to have LBBB-induced LV dysfunction after TAVR.

9.
Artículo en Inglés | MEDLINE | ID: mdl-37427306

RESUMEN

Background: Hypersensitivity reactions (HSRs) to components of cardiac implantable electronic devices (CIEDs) are rare but difficult to differentiate from device infection. Data on best management strategies of HSRs to CIEDs are lacking. The aims of this systematic review are to summarise the available literature on the aetiology, diagnosis and management of HSR in CIED patients and to provide guidance on best management strategies for these patients. Methods and results: A systematic search for publications on HSR to CIED in PubMed from January 1970 to November 2022 was conducted, resulting in 43 publications reporting on 57 individual cases. The quality of data was low. The mean age was 57 ± 21 years, and 48% of patients were women. The mean time from implant to diagnosis was 29 ± 59 months. Multiple allergens were identified in 11 patients (19%). In 14 cases (25%) no allergen was identified. Blood tests were mostly normal (55%), but eosinophilia (23%), raised inflammatory markers (18%) and raised immunoglobulin E (5%) were also encountered. Symptoms included local reactions, systemic reactions or both in 77%, 21% and 7% of patients, respectively. Explantation of CIED and reimplantation of another CIED coated with a non-allergenic material was usually successful. Use of topical or systemic steroids was associated with high failure rates. Conclusion: Based on the limited data available, the treatment of choice for HSRs to CIEDs is full CIED removal, reassessment of CIED indication and reimplantation of devices coated in non-allergenic materials. Steroids (topical/systemic) have limited efficiency and should not be used. There is an urgent need for further research in this field.

10.
Am J Emerg Med ; 30(6): 1015.e3-5, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21665405

RESUMEN

A 49-year-old man was admitted with high-risk left ventricular thrombosis and systemic embolization. Prompt and complete resolution of the thrombus was achieved under intravenous lepirudin administration but not under full-dose heparin treatment. Medical physicians, including emergency medicine physicians, cardiologists, cardiac surgeons, and hematologists, should become more aware of these alternative anticoagulant treatments, especially in cases when other therapeutic options (such as thrombolysis or cardiac surgery) may be associated with high morbidity or mortality.


Asunto(s)
Fibrinolíticos/uso terapéutico , Ventrículos Cardíacos , Heparina/uso terapéutico , Trombosis Coronaria/diagnóstico por imagen , Trombosis Coronaria/tratamiento farmacológico , Ecocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Hirudinas , Humanos , Masculino , Persona de Mediana Edad , Proteínas Recombinantes/uso terapéutico , Insuficiencia del Tratamiento , Resultado del Tratamiento
11.
JACC Case Rep ; 4(14): 854-856, 2022 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-35912334

RESUMEN

We report an exceptionally rare complication of cardiac pacing: a case of spontaneous fracture of a modern bipolar pacing lead that led to migration across a patent foramen ovale into the left atrium and embolic stroke. (Level of Difficulty: Advanced.).

12.
N Engl J Med ; 366(11): 1058-9; author reply 1060-1, 2012 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-22417264
14.
Arrhythm Electrophysiol Rev ; 8(2): 90-98, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-31114682

RESUMEN

The ability to drive is a highly valued freedom in the developed world. Sudden incapacitation while driving can result in injury or death for the driver and passengers or bystanders. Cardiovascular conditions are a primary cause for sudden incapacitation and regulations have long existed to restrict driving for patients with cardiac conditions at high risk of sudden incapacitation. Significant variation occurs between these rules in different countries and legislatures. Quantification of the potential risk of harm associated with various categories of drivers has attempted to make these regulations more objective. The assumptions on which these calculations are based are now old and less likely to reflect the reality of modern driving. Ultimately, a more individual assessment of risk with a combined assessment of the medical condition and the patient's driving behaviour may be appropriate. The development of driverless technologies may also have an impact on decision making in this field.

15.
J Am Soc Echocardiogr ; 32(11): 1451-1461.e3, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31558302

RESUMEN

BACKGROUND: Whether left ventricular (LV) longitudinal peak systolic segmental strain (LPSS) has sufficient reproducibility to be used in clinical practice (e.g., in patient follow-up) remains unclear. The aim of this study was to assess the reproducibility of combined acquisition and measurements of LPSS across the spectrum of LV ejection fraction (LVEF). METHODS: In this prospective study, 72 subjects (mean age, 63 ± 14 years; 65% men) were included in four equal groups: group 1, LVEF ≥ 50%, healthy; group 2, LVEF ≥ 50%, presence of cardiovascular disease and/or risk factors; group 3, LVEF 30%-49%; and group 4, LVEF ≤ 29%. Two observers performed four sets of image acquisitions and measurements (three during the same session, one after a median of 1 day) to account for intraobserver, interobserver, and test-retest reproducibility of combined acquisition and measurements. LPSS was measured in each of the 17 LV segments. RESULTS: On average, the intraobserver and test-retest intraclass correlation coefficients and mean absolute differences of repeated acquisition and measurement of LPSS were similar across groups. However, interobserver intraclass correlation coefficients and mean absolute differences decreased in group 4 compared with groups 1 to 3. The intraobserver, test-retest, and interobserver coefficients of variation of all LV segments became worse as LVEF decreased, especially in group 4, in which LPSS was not reproducible in most segments. Reproducibility of LPSS in basal LV segments was worse compared with apical segments. The average measurement uncertainty (defined as the 95% limits of agreement of repeated acquisition and measurements) of LPSS in a test-retest scenario was ±8.9%, ±11.8%, ±10.7%, and ±9.0% in groups 1, 2, 3, and 4, respectively. CONCLUSIONS: The clinical applicability of LPSS is hindered by suboptimal reproducibility, even if a single observer repeats both acquisition and measurements. Changes in LPSS during patient follow-up should be interpreted with caution.


Asunto(s)
Ecocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Contracción Miocárdica/fisiología , Volumen Sistólico/fisiología , Disfunción Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda/fisiología , Anciano , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Sístole , Disfunción Ventricular Izquierda/diagnóstico
16.
Europace ; 10(12): 1454-5, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18948364

RESUMEN

Persistent left superior vena cava (LSVC) is a rare congenital anomaly which can add difficulties in placing defibrillation leads and achieving good defibrillation thresholds. Previous reports described placement of leads at or near the right ventricular apex. We hereby report the first case of a dual-coil, active fixation defibrillation lead, successfully implanted into the anterior-septal right ventricular outflow tract, through a persistent LSVC.


Asunto(s)
Desfibriladores , Electrodos Implantados , Ventrículos Cardíacos/cirugía , Implantación de Prótesis/métodos , Vena Cava Superior/anomalías , Vena Cava Superior/cirugía , Anciano , Humanos , Masculino
17.
Am J Emerg Med ; 26(7): 839.e3-6, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18774061

RESUMEN

We present a rare case of noncardiogenic pulmonary edema (NCPE) associated with sudden coma due to severe hypoglycemia. We suggest that in every case of NCPE associated with coma, a rapid determination of glycemia should be provided because delays in diagnosis can lead to adverse outcome.


Asunto(s)
Hipoglucemia/complicaciones , Edema Pulmonar/etiología , Electrocardiografía , Escala de Coma de Glasgow , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemiantes/efectos adversos , Insulina/efectos adversos , Masculino , Persona de Mediana Edad , Edema Pulmonar/diagnóstico , Edema Pulmonar/fisiopatología
18.
Expert Rev Cardiovasc Ther ; 15(8): 601-618, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28724315

RESUMEN

INTRODUCTION: Atrial fibrillation (AF) is the most common human arrhythmia. AF is a progressive disease, initially being nonsustained and induced by trigger activity, and progressing towards persistent AF through alteration of the atrial myocardial substrate. Treatment of AF aims to decrease the risk of stroke and improve the quality of life, by preventing recurrences (rhythm control) or controlling the heart rate during AF (rate control). In the last 20 years, catheter-based and, less frequently, surgical and hybrid ablation techniques have proven more successful compared with drug therapy in achieving rhythm control in patients with AF. However, the efficiency of ablation techniques varies greatly, being highest in paroxysmal and lowest in long-term persistent AF. Areas covered: In this review, we discuss the fundamental differences between paroxysmal and persistent AF and the potential impact of those differences on patient management, emphasizing the available therapeutic strategies to achieve rhythm control. Expert commentary: Treatment to prevent AF recurrences is suboptimal, particularly in patients with persistent AF. Emerging technologies, such as documentation of atrial fibrosis using magnetic resonance imaging and documentation of electrical substrate using advanced electrocardiographic imaging techniques are likely to provide valuable insights about patient-specific tailoring of treatments.


Asunto(s)
Fibrilación Atrial/terapia , Adulto , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Manejo de la Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA