Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
BMC Geriatr ; 21(1): 401, 2021 06 30.
Artículo en Inglés | MEDLINE | ID: mdl-34193082

RESUMEN

BACKGROUND: Anxious symptoms have a negative impact on different aspects of the elderly's quality of life, ranging from the adoption of unhealthy lifestyle behaviours to an increased functional impairment and a greater physical disability. Different brief assessment instruments have been developed as efficacy measures of geriatric anxiety in order to overcome psychometric weaknesses of its long form. Among these, the 10-item Geriatric Anxiety Scale (GAS-10) showed strong psychometric properties in community-dwelling samples. However, its diagnostic accuracy is still unexplored, as well as its discriminative power in clinical samples. METHODS: In the present study, we explored the psychometric performance of the GAS-10 in the elderly through Item Response Theory in a sample of 1200 Italian community-dwelling middle-aged and elderly adults (53.8% males, mean age = 65.21 ± 9.19 years). Concurrent validity, as well as diagnostic accuracy, was examined in a non-clinical sample (N = 229; 46.72% males) and clinical sample composed of 35 elderly outpatients (74.28% females) with Generalized Anxiety Disorder (GAD). RESULTS: The GAS-10 displayed good internal construct validity, with unidimensional structure and no local dependency, good accuracy, and no signs of Differential Item Functioning (DIF) or measurement bias due to gender, but negligible due to the age. Differences in concurrent validity and diagnostic accuracy among the long form version of the GAS and the GAS-10 were not found significant. The GAS-10 may be more useful than the longer versions in many clinical and research applications, when time constraints or fatigue are issues. CONCLUSION: Using the ROC curve, the GAS-10 showed good discriminant validity in categorizing outpatients with GAD disorder, and high anxiety symptoms as measured by the GAS-SF cut-off. The stable cut-off point provided could enhance the clinical usefulness of the GAS-10, which seems to be a promising valid and reliable tool for maximize diagnostic accuracy of geriatric anxiety symptoms.


Asunto(s)
Ansiedad , Calidad de Vida , Anciano , Ansiedad/diagnóstico , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Psicometría , Reproducibilidad de los Resultados
2.
Assist Inferm Ric ; 35(4): 174-179, 2016.
Artículo en Italiano | MEDLINE | ID: mdl-28151509

RESUMEN

. Evaluation of tip location reliability of intraprocedural ECG vs. chest Xrays in PICC placement. INTRODUCTION: Among the methods to assess the correct positioning of the tip of central venous catheters, the ECG method is safe and reliable. AIM: To compare the reliability of tip location by intraprocedural ECG and post-procedural radiological examination as implemented in routine care in a tertiary hospital PICC Team. METHODS: 119 PICCs positioned by the Monza hospital PICC Team were examined positioned by either ECG technique or post procedural x-rays technique. The tip location was assessed in retrospect, through occasional chest ray reports. We assessed the reliability of the ECG and X rays techniques. RESULTS: In the ECG group (75 catheters), 71 (95.7%) were correctly located vs 33/44 (75%) in the x-rays group. CONCLUSIONS: Tip location by ECG technique implemented by the PICC team is feasible and safe. The cost/benefit ratio suggests its adoption as main tip location technique.


Asunto(s)
Cateterismo Periférico/normas , Electrocardiografía , Radiografía Torácica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
3.
Dalton Trans ; (22): 2698-705, 2006 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-16804582

RESUMEN

The complexes [Pd(eta2-dmfu)(P-N)] [P-N = 2-(PPh2)C6H4-1-CH=NR, R = C(6)H(4)OMe-4; CHMe2; C6H3Me2-2,6; C6H3(CHMe2)-2,6] react with an excess of BrC6H4R1-4 (R1= CF3; Me) yielding the oxidative addition products [PdBr(C6H4R1-4)(P-N)] at different rates depending on R [C6H4OMe-4 > C6H3(CHMe2)-2,6 > CHMe2 approximately C6H3Me2-2,6] and R1 (CF3>> Me). In the presence of K2CO3 and activated olefins (ol = dmfu, fn), the latter compounds react with an excess of 4-R2C6H4B(OH)2 (R2= H, Me, OMe, Cl) to give [Pd(eta2-ol)(P-N)] and the corresponding biaryl through transmetallation and fast reductive elimination. The transmetallation proceeds via a palladium(II) intermediate with an O-bonded boron anion, the formation of which is markedly retarded by increasing the bulkiness of R. The intermediate was isolated for R = CHMe2, R1 = CF3 and R2= H. The boron anion is formulated as a diphenylborinate anion associated with phenylboronic acid and/or as a phenylboronate anion associated with diphenylborinic acid. In general, the oxidative addition proceeds at a lower rate than transmetallation and represents the rate-determining-step in the coupling reaction of aryl bromides with arylboronic acids catalyzed by [Pd(eta2-dmfu)(P-N)].

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA